Safe operation of the rotating anode x-ray generator in room 1128 ERB. Emergency power disconnect

Similar documents
Radiation Safety Requirements for the Use of Non-Medical X- Ray.

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

RADIATION CONTROL - RADIATION SAFETY REQUIREMENTS FOR PARTICLE ACCELERATORS NOT USED IN THE HEALING ARTS

STANDARD OPERATING PROCEDURE

PART I RADIATION SAFETY REQUIREMENTS FOR PARTICLE ACCELERATORS

Filament Change. Procedure for changing burnt X-Ray Generator Filament and replacing it with a new filament

Maximum output power with circulator Wo 6 kw. Maximum output power without circulator Wo 5 kw

Hybrid & Electric Cars Guidance for organisers of Speed events

Technical Service Bulletin IOX/DCX Transmitter Maintenance Schedule

CHAPTER 40 PROFESSIONAL LICENSING AND FACILITY REGULATION. PART 13 Radiation Safety Requirements for Particle Accelerators

AVOIDING ELECTROCUTION HAZARDS

In general this document presents specific safety procedures for systems with potentially lethal voltages on bare or exposed conductors.

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

MODULE 6 Lower Anchors & Tethers for CHildren

P239-1 Supply Pumper Instructions

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

NLCTA Accelerator Safety Envelope

Electrical Safety CSA Z462 & NB Regulations

Arc flash hazard mitigation

PREVIEW ONLY - FULL COPY AVAILABLE TO CONSORTIUM MEMBERS. Escalator Specific Electrical Systems. Course 209 PARTICIPANT GUIDE

4 What We Know About Fuel Cells

Presenter s Notes SLIDE 1

Why Electric Safety Standards

Powered Industrial Trucks

Operating procedures relating to the use of electrical equipment and installations

ELECTRICAL. 60 Minutes

RESTWELL RISE & RECLINE ARMCHAIRS LARS AND SVEN - OWNER S HANDBOOK MODEL DESCRIPTION

AOE DEPARTMENT SAFETY REVIEW FORM FOR EXPERIMENTAL RIGS

Portable Sanitizing Wand. Model: VH03. The CleanWave Portable Sanitizing Wand kills up to 99.9% of germs and odorcausing. surfaces.

RESTWELL RISE & RECLINE ARMCHAIRS INTALIFT - OWNER S HANDBOOK PARTS DESCRIPTION

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

WELLS RURAL ELECTRIC COMPANY Adopted: March 1976 Revised: March 21, 2017 Reviewed: August 21, 1998 RULE NO. 2

Experiences from First Top-Off Injection At The Stanford Synchrotron Radiation Lightsource

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

Instruction Manual. Q Series 2 Motor Control Modules - OEM

Hydraulic Immediate Need Power Pack

Hydraulic PTO Flow Device

XR200 X-RAY SOURCE OPERATOR S MANUAL

FACT SHEET Standard: Electrical Safety

The Participant will select one of the two Approval Categories (below) and submit the appropriate documentation.

Golf cart safety. Don t Let A Golf Cart Accident ruin Your Game! Clip Art Courtesy of:

REGULATORY CONTROL OF X-RAY SCANNING OF PASSENGER CARS

Powered Industrial Truck Safety Program

Powerware Vdc Extended Battery Cabinet User s Guide.

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

Diesel Locomotive Train Driver. Lesson Plan and WorkBook

Activity 8: Solar-Electric System Puzzle

RESTWELL RISE & RECLINE ARMCHAIRS OWNER S HANDBOOK PARTS DESCRIPTION

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

CLASSIFIED 5 MAGNETISM ELECTROMAGNETIC INDUCTION GENERATOR MOTOR - TRANSFORMER. Mr. Hussam Samir

FRM II Converter Facility

e-track Certified Driver Operating Manual

First Responder Beware

Elevator Hydraulic Machine Room Instructor s Guide

National Grid UK Electricity Transmission plc. NATIONAL SAFETY INSTRUCTION and Guidance

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

Lids, Leaks, Labels and Location All About Satellite Accumulation Martin E. Sánchez Environmental Specialist 3

OpenEVSE - 40A Charging Station

Induction Voltage Hazards

Unrestricted. S.Mukhopadhyay

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

Guidelines for Safety Training of Overhead Crane Operators and Supervisors

Suncor Energy Products Ottawa Terminal Drivers Examination

North Lyon County Fire Protection District. Seasonal Firefighter Job Description

Safety Training Topic ELECTRICAL SAFETY

VERSUS GAS USA 1/1/2013

IB PowlVac ITE-HK Remote Racking Device

Electrical Installation

Oconee Nuclear Station ALLOY 600 REPAIRS 1EOC23

Biasing the Vintage Series (Nomad, BelAir, VT50, Vintage 33)

Off-Road Skills Demonstration

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

The University of Kansas VEHICLE RENTAL. Guidelines for Users at the Lawrence Campus. Revised spring

Atomic Absorption Spectroscopy

Owner s Manual GLASSLINED PUMP TANK

Installing the Switch

LDLS Laser-Driven Light Source. EQ-1000 High Brightness DUV Light Source. Operation Manual

Evaluation of the interlock programme for DUI offenders in Finland

Diesel Locomotive Train Driver Performance Checklist

In order to apply for the ProGuard Program, please follow the below steps:

Train Examination (Braking System) Addendum. Lesson Plan and WorkBook

VH03 SAVE THESE INSTRUCTIONS

Now - Up To 400A Mains!

Safety, Installation and Service Manual Models 1952, 1953 & 1972

Under-Vehicle Inspection Drive Train Part 2

Remedial and Ignition Interlock Programs Policies and Guidelines

"ELECTRICAL SAFETY IN THE WORKPLACE"

N-02 MAINTENANCE MECHANIC TRAINING SKILL DEVELOPMENT GUIDE

PAD-MOUNTED SWITCHGEAR INSPECTION & MAINTENANCE RECOMMENDATIONS TYPE PSI/II. 15kV 25kV. Qualified Persons

K-SERIES PUBLIC USE LIFT OPERATING INSTRUCTIONS

NEDG SERIES DUAL E-BEAM GUN SWITCHING POWER SUPPLIES

ELECTRICAL AREA CONTROLLED ACCESS PROCEDURE SP-18 NATIONAL HIGH MAGNETIC FIELD LABORATORY NHMFL FLORIDA STATE UNIVERSITY SAFETY PROCEDURE SP-18

6. Document tasks performed during visit and report any observations to the appropriate

Rental Industry Safety Tester Safe Check 5s

NATIONAL CERTIFICATE (VOCATIONAL) NQF LEVEL 3 NOVEMBER

Gilmer ISD Transportation Department

Boom Lift Platform Capacity Reduction Manual. For Set Lighting Technicians and Studio Grips

Underground Storage Tank Certification Examinations. Presentation to ASTSWMO November 27, 2007 UST SYSTEM OPERATOR CERTIFICATION

Marina Bay Sands Guidelines for Electrical and Wiring Service

School Driver Trainer Inservice

Transcription:

Safe operation of the rotating anode x-ray generator in room 1128 ERB Contact: Paul Evans, evans@engr.wisc.edu, August 13, 2008 Important Notes 1. The rotating anode x-ray generator produces x-rays by accelerating electrons across a high voltage. With the shielding in place, there is no detectable flux of x-rays into the room. Under unusual conditions, or if the shielding fails, the generator can emit x-rays at potentially harmful intensities. In an emergency, switch off the machine s power using the disconnect switch located behind and to the right of the x-ray machine or simply leave the room and ask for help. If there is a problem reaching the emergency power disconnect, the power for the generator may be removed using circuit breaker 4 in panel PP-7 near the freight elevator on the 11 th floor. (There are two panels; PP-7 is the nearest panel to the freight elevator. The labels for the panels are printed on the inside of the access door.) Emergency power disconnect Wall Rotating anode x-ray generator Huber diffractometer Electronics rack Desk with computer Figure 1 Location of Emergency Electrical Disconnect 2. The x-ray generator may only be used by Authorized Users. A list of authorized users can be found in the current version of this document in the red safety binder in room 1128. 3. If you have any doubts about the safety of what you are doing, turn off the x-ray machine and seek help. 1

Contents Important Notes... 1 1. Introduction... 3 2. Users and Becoming an Authorized User... 3 3. Radiation Safety... 3 4. Electrical Safety... 4 5. Procedures for Use... 4 a. Mandatory use of the log book... 4 b. Turning the generator on and off... 4 c. Extended unattended use (including overnight)... 5 d. Shutting off the generator or chiller in case of a fire, electrical problem, or water leak... 5 Appendix A: Resources... 8 1. Radiation protection resources... 8 2. Equipment manuals... 9 Appendix B: In-Use Card...10 Appendix C: List of Authorized Users... 11 2

1. Introduction The rotating anode x-ray generator in room 1128 of the Engineering Research Building is an extremely intense laboratory-based source of x-rays. This document describes the requirements its safe operation with respect to radiation safety, electrical safety, and mandatory procedures. 1. Radiation Safety The rotating anode x-ray machine in ERB 1128 is capable of producing x-ray intensities that can be harmful both immediately and after cumulative exposure. Users must understand their responsibilities with respect to radiation exposure to themselves and to others who may enter the room. 2. Electrical Safety The voltages and currents used to operate the rotating anode x-ray machine are potentially extremely dangerous. 3. Procedures for Use Users are required to follow a set of standard procedures while using the x-ray generator and diffractometer. Safety comes first! Do not use the x-ray machine if you have any doubt about your safety or the safety of others. 2. Users and Becoming an Authorized User The x-ray generator and x-ray diffractometer may only be used by authorized users. Visitors and others may participate in using the machine only when an authorized user is present. To become an authorized user requires completing the following steps: 1. Attend the radiation safety training offered by the University s Safety Department. 2. Read and understand Chapter 10 of the University of Wisconsin Radiation Safety for Radiation Workers Training Manual. 3. Read and understand this entire document. 4. Demonstrate an understanding of the safety features of the generator and the locations of emergency shut-offs. 5. Complete an entry in Appendix C of this manual. 3. Radiation Safety In normal operation users will not be exposed to radiation while using the x-ray generator in ERB 1128. There is, however, the potential for dangerous exposure in unusual circumstances It is extremely important to act responsibly with respect to possible radiation exposure because it is possible to put others at risk without their knowledge. X-ray exposure is undetectable and can lead to chronic problems without any acute symptoms, so it is essential to act responsibly. The background dose during normal operation falls well below the regulatory requirements and the University s safety office has not required us to wear dosimeters while using this instrument. a. The enclosure of the generator and diffractometer There are several features of the x-ray system that prevent accidental exposure to the direct beam from the rotating anode. Among these are: 1. A coupler between the x-ray generator and flight path that forces a mechanical x-ray shutter to close if the coupler is removed or the flight path is not present. 2. A shielded enclosure that absorbs scattered radiation and the fraction of the direct beam that is transported past the sample. 3

3. An electromagnetic shutter that can be opened only if the door to the x-ray enclosure is closed. 4. The rotating anode will stop and the electron beam will be switched off if the door to the enclosure is opened while the shutter is open. Users may not bypass any of these safety features. b. Opening the enclosure while the generator is operating Normally, the generator will turn off if the door is opened while the generator is running. This feature can safely be bypassed by pressing the Door Open on the generator control panel. Doing this is completely safe. The ability to open the enclosure with the generator operating and the shutter closed is indispensable because it allows the sample, slits, etc. to be adjusted without turning off the generator. c. Bypassing the enclosure interlock In some special cases it may be necessary to open the door to the enclosure while electromagnetic x-ray shutter is open. This can be done using the turn key on the front panel of the x-ray generator and then pressing the Door Open button. Opening the enclosure with the shutter open can be extremely dangerous because it could allow you to be exposed to the direct beam. The shutter interlock should be bypassed only at the lowest generator power and for short periods of times. Users may not under any circumstances bypass the interlock without supervision. 4. Electrical Safety The x-ray generator uses large currents and high voltages. The cathode can be biased at voltages up to 60 kv and can produce currents up to 300 ma. Power for the generator is provided by a three-phase 208 V AC circuit rated at 100 A. The generator can draw up to 18 kw, which presents a risk of electrocution, burns, and fire if there is an electrical problem. The water chiller and circulator is powered from a separate 250 V 30 A circuit. Users should immediately shut off the generator or chiller if they expect an electrical problem. The procedures for doing this are given in part d of section 5, below. 5. Procedures for Use a. Mandatory use of the log book All use of the rotating anode x-ray machine must be reported in the log book in 1128. Anything unusual must be noted in the book. Doing this is a safety issue because safe operation depends on proper shielding and electrical and water safety. b. Turning the generator on and off Electrical arcs can be produced by operating the rotating anode generator improperly. These are usually harmless, but have the potential to damage the generator. These problems can be avoided by operating the generator using the following procedures. 4

i. Turning the generator on The rotating anode x-ray generator is almost always left in a state where the turbomolecular pump is operating but the anode is not biased and not rotating. From this state, the generator can be turned on with the following procedure. 1. Verify that the valves supplying water to the Haskris chiller are open 2. Turn on the Haskris chiller using the switch on its front panel. 3. Push the Power on button on the front panel of the x-ray generator. 4. Once the water is on, the message on the front panel of the generator will switch from Power on now. to Ready now. 5. Be sure that the generator says Ready now. Then push the X-ray on button on the generator. The anode will begin to rotate and an electron beam with a bias of 20 kv and current of 10 ma will be started. This is the lowest power under which the generator can be operated. 6. The generator is operated at much higher power than it initially reaches. The maximum power depends on the choice of cathode and filament. At present, the maximum power is 5.4 kw. The generator can be safely raised to this power by increasing the power in two to three steps over a total of 10 to 15 minutes. ii. Turning the generator off 1. Decrease the generator power from the high power used in experiments to the minimum power 20 kv, 10 ma in several steps taking a total of 5 to 10 minutes. 2. Push the x-ray off button on the front panel of the generator. 3. Push the power off button on the front panel of the generator. 4. Switch off the Haskris chiller. 5. The generator can be left in this state indefinitely. c. Extended unattended use (including overnight) When necessary, the rotating anode generator can be operated unattended or remotely for extended periods of time. This can be useful in acquiring diffraction data at a large number of points in reciprocal space, for example. Any of the authorized users of the machine may do this at their discretion, provided the following rules are followed: 1. The In-Use card must be completed and posted on the door to room 1128. This card can be found in Appendix B. 2. Users leaving the x-ray machine running unattended must provide a phone number where they can be reached. These rules must be observed in order to protect the other occupants of the building and for the safety of maintenance people who respond to water leaks, fires, and other problems. d. Shutting off the generator or chiller in case of a fire, electrical problem, or water leak i. X-ray generator In some cases an electrical or radiation safety problem may require the generator to be switched off immediately. There are three ways to do this. 1. Push the Power Off button on the generator. This will switch off the bias voltage and electron current, but it will not remove power from the rest of the generator electronics. This 5

will remove the radiation hazard immediately, but will not completely remove an electrical hazard. 2. Switch off the power to the generator using the emergency disconnect on the supply panel on the wall behind the x-ray machine. The location of this disconnect is shown in Figure 1 on page 1. This will completely remove power from the generator, including the vacuum pumps, and control electronics. Do this if you suspect a fire in the generator s electronics. 3. The power can also be removed from the system by switching off the main circuit breaker supplying the generator. The power to the generator is supplied by circuit breaker 4 in panel PP-7 near the freight elevator on the 11 th floor. (There are two panels; PP-7 is the nearest panel to the freight elevator. The labels for the panels are printed on the inside of the access door.) The location of the circuit breaker is shown in Figure 2. Note: The diffractometer and other equipment are powered separately from the generator and will not be switched off if steps 2 or 3 are followed. Figure 2 Circuit breaker supplying the rotating anode x-ray generator. ii. Chiller The chiller can draw up to 30 A from a 250 V circuit, so it can also be a significant electrical or fire hazard. There are two ways to shut off the chiller: 1. The chiller can be shut off at any time using the switch on its front panel. If the x-ray generator is running it will immediately shut off because as the water flow and water pressure fall. 2. The chiller may be shut off at its circuit breaker (breakers 13,15, and 17, labeled Chiller 1128 in panel RPDF 11 in the hall outside 1128.) The location of the circuit breaker is shown in Figure 3. 6

Figure 3 Location of the water chiller circuit breaker. iii. Water supply The chiller is cooled by water drawn from the city water supply. This water supply can be shut off at any time by closing the shut off valve shown in Figure 4. If the chiller and x-ray generator are running, doing this will cause the chiller to overheat and shut down within a few minutes. Figure 4 Water shut off valve. 7

Appendix A: Resources 1. Radiation protection resources a. University of Wisconsin Radiation Safety for Radiation Workers Training Manual This manual describes the University s guidelines for working with radiation sources based on radioactive isotopes, x-ray generators, and lasers. The section on analytical x-ray machines is Chapter 10. The requirements for shielding x-ray generators are given on page 161: The leakage radiation from the x-ray tube housing, with all shutters closed, must not exceed 2.5 mr/hr at 5 cm from the surface. The x-ray generator must have a protective cabinet which limits leakage radiation at 5 cm from the surface to 0.25 mr/hr or less. This helps to insure that the background radiation within the room or immediate vicinity of the generator is low. The manual also includes a very nice discussion of the basic components of analytical x- ray systems and strategies for mitigating doses. There is a copy of this manual in the cabinet in 1128 ERB it is also available at http://www2.fpm.wisc.edu/safety/radiation/trainman.htm. b. Radiation safety training The University of Wisconsin offers a weekly radiation safety training course. More information is available at http://www2.fpm.wisc.edu/safety/radiation/schedu.html. c. Wisconsin Radiation Safety Regulations The state of Wisconsin has regulations that require safety training for people who work with radiation. The regulations can be found at http://www2.fpm.wisc.edu/safety/radiation/docs/regs.pdf. Our requirements for authorized users are based on the following rule on page 18: 7. Persons only working with machine produced radiation (e.g., x-ray diffraction) should review Chapter 10, Radiation Safety for Radiation Workers and be briefed on the basic safety measures for the particular source they will be using. d. University of Wisconsin Safety Department FAQs The University of Wisconsin Safety Department has answers to frequently asked questions at http://www2.fpm.wisc.edu/safety/radiation/faq.htm. The most relevant question for the rotating anode x-ray machine in 1128 ERB is: X-ray / Laser Q: What about X-ray machines, analytical devices (e.g., x-ray diffraction, electron microscope) or lasers? A: Call Radiation Safety, 262-9748, to receive an x-ray survey, training, check on your x- ray / laser system and insure the state licensing paperwork is completed and forwarded. e. Guide to Beamline Radiation Shielding Design at the Advanced Photon Source There s a discussion of shielding strategies and requirements in the original design documents for the Advanced Photon Source. They have very different requirements for shielding because the spectrum and divergence of radiation from undulators, but the goals of 8

shielding are similar. The document is at: http://www.aps.anl.gov/science/publications/techbulletins/tb7/tb-7_toc.html 2. Equipment manuals The manual for the Rigaku x-ray generator is available on paper in the cabinet in room 1128 and at http://xray.engr.wisc.edu/equipment.shtml. 9

Appendix B: In-Use Card Caution X-ray Generator in Unattended Use User: Email: Home Phone: Work Phone: Date and Time this Form was Completed: Date and Time User Will Return: Please contact the user or Paul Evans (evans@engr.wisc.edu, work (608) 265-6773, home (608) 233-3746) with any problems. 10

Appendix C: List of Authorized Users Name Email address Date Signature Signature of Trainer 11