EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Progressive distributor VPB

Similar documents
EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Progressive distributor VPA-D

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Progressive distributor VPA-B

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Volume flow meter with throttle- and bypass valve KUZ-L

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Progressive distributor VPA-C

EUGEN WOERNER GmbH & Co. KG Postfach 1661 D Wertheim Am Eichamt 8 D Wertheim

One-line distributor e.g. VEI-A. One-line aggregate GEI-A

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump aggregate. Drive: Use:

Block feeder SPVS Used in oil or grease lubrication systems

Block feeder SPVS Used in oil or grease lubrication systems

Block metering device VPB. Block feeder for use in oil or grease lubrication systems

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim

Motor-driven pump unit GSJB

Flow limiter SP/SMB13 for line installation in circulating-oil lubrication systems.

Flow limiter SP/SMB3 Flow limiter SP/SMB6

Table of contents. Table of contents. Overview of progressive distributor Distributor bridge without outlet...

Kuhnke Technical Data. Contact Details

Flow Monitors and Sensors

UD and UC Gear pump unit

System description for cylinder lubrication and valve seat lubrication on large 4-stroke diesel engines

PSG product series. Modular feeder. For oil and grease For use in SKF ProFlex progressive and SKF CircOil circulating centralized lubrication systems

PTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2

Flow limiter SP/SMB US

Metering Units and Piston Distributors with Quick Connector System

Injection oilers, micro pumps for minimal quantity metering

Flow limiter SP/SMB9 for mounting plates

Kuhnke Technical Data. Contact Details

PPU, PHU Piston Pumps for progressive grease and oil systems, pneumatically or hydraulically actuated

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

For grease For application in SKF DuoFlex dual-line centralized lubrication systems

CPLab / CP Factory. Application module magazine. Data sheets

Grease-lubricating pump FF... DSK US (05.05)

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

PNEUMATIC CYLINDERS CYLINDERS ISO solutions SERIES 21 SERIES 21 CYLINDERS ISO 15552

Progressive Central Lubrication Systems

Progressive distributor SXE-2

2/2 Pressure operated valves

Manually or pneumatically actuated piston pumps

Directional Valves for oil or grease

Product series DSA, DSB, DSC, DSD

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Ex m Solenoid Operator Type 0519

Injection oilers, micro pumps

Manually or pneumatically actuated Piston pumps

Single-Line Centralized Lubrication Systems

Progressive distributor MX-F

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

Flap-Type Flow Meter Prall

Flow limiter SP/SMB 8... DSK US (09.04)

Digital Pressure Regulator Sentronic PLUS Series 614

GRIPPERS SERIES P3 - P12 ACTUATORS

Injection Oilers, Micro Pumps

Operating Instruction for Flowmonitor. Model: DF-WM

Piston Distributors, Metering Units

Swing Piston Compressors and Vacuum Pumps

Instruction Manual EDS-75-S EDS-100-S/F EDS-160-S/F EDS-200-S/F EDS-220-Z EDS-250-S/F

GREASE NLGI (*) OIL CST (*) PRESSURE (220.5) (147) - 20 (294) (220.5)

SKF Multilube pumping unit

Operating Instructions for Viscosity Compensated Flow Meter / Monitor. Model: VKM

Flow limiter SP/SMB10 Dual flow series

Type 2000, 2002, 2012

Grease Pump Units For progressive and multiline systems, manually, pneumatically or hydraulically actuated

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Standard strokes (for all diameters) Stroke tolerance (ISO 15552)

For high-viscosity oils and fluid grease of NLGI grades 000, 00 For use in SKF MonoFlex single-line centralized lubrication systems

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-PSG3S/3GD

Series Cylinders according to standard ISO 15552

Sentronic PLUS 614 Series

Pump elements. Pump elements. Pump elements PE 60 / PE 120 / PE 170 (with pressure limiting valve)

On/Off- Solenoid to RL 94/9/EG (ATEX 95) G HP E

Grease Lubrication Pump FK

DX³ RCCBs - ID 4P up to 100 A

Grease Pump Units. For progressive and multiline systems, manually, pneumatically or hydraulically actuated. Please note!

Assembly and operating Instructions Bypass Flow Meter DST

Installation and Operating Instructions. Variable area flow meter RA 65 / FA 65

Grease lubricating pump FB DSK US (06.02)

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

NOTE Please read this Operating Manual carefully before first using the device and strictly adhere to the instructions!

RX 3 M.C.B A up to 63 A

System 6. ü ( System 6

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Type Modular Water Valve System servo-assisted; variable and extendable. 2/2 way; DN mm; 1 up to 7 bar Advantages / Benefits

RX 3 M.C.B A up to 63 A

Standard filter Disk filter Return filter. Lubrication systems can fail from the following

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

CTE8000 / CTU8000 Series

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump unit GMZ-E

Solenoid valve. Technical data Orifice 1/4 4 Body materials Actuator material Seal material Media Viscosity. Control medium Port connections

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

TX³ RCCBs 2P up to 100 A

Accessories for Minimal Quantity Metering

Differential pressure switches for air, flue and exhaust gases Pressure switch for gas

System 8. Solenoid Coils Armature Assemblies Valve Systems. Nass Controls LP Nass Magnet GmbH Precision Controls Kft.

Pressure switch for gas, GW 500 A4 GW 500 A4/2

Chapter B-3. Chapter 3. Actuators and output devices. Festo Didactic TP101

Diaphragm Vacuum Pumps and Compressors

Transcription:

Progressive distributor VPB Use: In progressive mode based central lubrication systems. The main features of WOERNER progressive distributors are as follows: Accurate proportioning volumes. different proportioning volumes selectable in accordance with the lubricant volume required. Extremely long service life due to refined sliding surfaces. Easy combination of opposing outlets Various options for monitoring Technical data: Proportioning volume per cycle: Distinctive colour green Distinctive colour yellow Distinctive colour red on request 0,09 cm³ 0, cm³ 0,0 cm³ 0,0 cm³ Lubrication point connections at max.: 0 Operating pressure at max.: 0 bar Throughput volume in case of: Oil at max.: 700 cm³/min Grease at max.: 70 cm³/min Delivery medium: Oil-viscosity: > cp Grease up to: NLGI category Material: Outer body: VPB-B: VPB-H: Internal parts: Aluminium anodised Bronze seawater-resistant Steel A = Mounting point at distributor ( for viewing indicator and electrical functionality check) B = Mounting point for viewing indicator at distributor (if point A is occupied) H = Input line Number of outlets 8 Length Weight [kg] "a" VPB-B VPB-H 7 0,8 0,8 90 0,7,0 Temperature range: -0... +80 C Lubricant: The intended lubricant must be suitable for use with centralized lubrication equipment. Mounting position: usually as needed K = Proportioning volume distinctive colours (see technical data) S = Note to proportioning volume distinctive colours X = Outlet screwing for pipe outer diameters or, connection hole in distributor for double-cone ring DIN 8 and ALL male fitting DIN 87 with thread M0x 0 8 0 07 0,7,7 0,,7 0,7,9 8 0,8,89 7 0,9, 9,0, Note: In case of heavy vibration or shock load, install the distributor such that piston axes are situated vertically to the main direction of shock impact. The distributor must not be "distorted". Therefore, when mounting it, be careful that the supporting surface is flat. Progressive distributor VPB 0.00 Postfach DE-978 Wertheim Replaces No. Page of 7 078.0.0 EN 078..09 EN

Visual check "S" Functional checks: Visual check "S": In a translucent polyamide receptacle, a red pin being fixed to the piston shows the piston's movement. Receptacle material: Polyamide, translucent Ambient temperature: -0... +80 C Weight: 0,0 kg Mounting point at distributor: Aor B Version "M" Electrical check with initiator: A pin being connected with the piston attenuates an initiator once per cycle. Material: Holder: VPB-B: VPB-H: ) Aluminium Bronze Indicator pin:. On the functional checking device "M", the metering volume at the last point (opposite the initiator's side) decreases by % for design-related reasons. Version "M" ) Version initiator "M" with cable: Operating voltage: 8... 0 VDC Residual ripple: 0 % Output: Closer, plus switching PNP Load current at max.: 00 ma Protection system: IP7 Connection: Cable m Connection diagram: Version initiator "M" with -pin unit plug (M): (for matching cable jack see auxiliaries) Operating voltage: 8... 0 VDC Residual ripple: 0 % Output: Closer, plus switching PNP Load current at max.: 00 ma Protection system: IP Connection: Unit plug Connection diagram: Postfach DE-978 Wertheim Page of 7

Version "RK" Electrical check with reed contact: A magnet connected with the piston switches a reed contact once per cycle. Switching voltage: 0... VUC Switching current at max.: ma Switching power at max.: 0,9 VA Ambient temperature: -... +80 C Version "RS" Version "RK" with cable: Material (receptacle): PA or.0 System of protection: IP Cable Length: 0 m Cross section: x0,7 mm² Material: Oelflex Connection diagram: Version "RS" with unit plug, -pin (M): (for matching cable jack see auxiliaries) Material (receptacle): PA or.0 Connection Diagram: Auxiliaries: Cable jack for functional check "RS" and initiator "M" (state purchase-no., please) Cable jack with LED and cable LED yellow = function display green = operating voltage Cable jack with terminal clamps Cable jack with LED and cable: Purchase-no.: Operating voltage: Cable Cross section: Length: System of protection: Cable jack with terminal clamps: (without LED) Purchase-no.: Connection type: Connection cross section: Cable diameter: System of protection: 9.0-9 0... 0 VDC x0, mm² m IP8 9.0- Screws at max. 0,7 mm²... mm IP7 Postfach DE-978 Wertheim Page of 7

Purchase-designation: Progressive distributor VPB- Material outer body Number of outlets Pipe screwing for outlet Visual check Functional check electrical control Prop. volume p. piston stroke and outlet [cm³] distinctive no. Gasket material Aluminium anodised B Bronze seawater resistant ) H... 0 increasing by outlets each without 0 Ø Ø without 0 with S without mount without initiator M0 Initiator with cable M Initiator with plug M Reed contact with cable RK Reed conact with plug RS 0,0 on request ) 0 0,09 09 0, 0,0 0 NBR (Perbunan) FPM (Viton) Note: When a functionality checking device is to be mounted, the proportioning volume must be 0,0 cm³ at the last point! On the functional checking device "M", the metering volume at the last point (opposite the initiator's side) decreases by % for design-related reasons. Scheme Distributor view ) ) Informations regard leaflet-no. S078! only possible with... 0 outlets! Purchase-example: (for the distributor shown) yellow red green yellow red Progressive distributor VPB; outer body anodised; outlets; for pipe outer diameter ; without visual check; with reed contact (cable); Proportioning volume, 0, 0, 09, 09,, 0; gasket material viton. SideA(R) Centre Side B (L) Purchase-designation: VPB-B / / / 0 / RK / / 0 / 0 / 09 / 09 / / 0 / V Side A(R) : V O B B B B O Centre : K Z K K Z K K Side B (L) : O O V O O B B Postfach DE-978 Wertheim Page of 7

Combinaton of outlets, doubling the proportioning volume at an outlet: R Connect opposing outlets by removing the "Z" screw. Close any of the outlets by means of a screwed sealing plug. Without "Z" screw removal, no outlet must be locked. Z The "Z" screw can be loosened and removed by using a size allen key. Auxiliaries: Threaded components ALL Progressive distributor Bridge Lock screw Pipe screwing ALL Ø Pipe screwing ALL Ø VPB-B 0.07-0.0-0.- 0.- VPB-H 0.07-0.0-0.- 0.- Plug screw connections ) Material Brass nickelized Check valves ) Pipe AD straight screw-in union swivel equal-elbow-fitting 9.00-0 9.00-9.00-7 Further informations: Leaflet-no. 0 Fastening torque max. Nm To be used with flexible pipes only. Material Pipe AD Outlet Order no. Further informations 0.078- Cutting ring union Leaflet-no. 09 Steel galvanized 0.077- ALL 0.08- Leaflet-no. 070 ) Beneath monitoring elements, can be used only with extension 0.09-! Combination of outlets: opposing outlets are combined into one outlet by removing the "Z" screw and closing the outlets. Distinctive letters: O = open outlet V = Locking screw B = double bridge K = opposing outlets connected. Z = opposing outlets separated. SideA(R) Centre Side B (L) outlets are combined by means of bridges and removing two "Z" screws. Single outlet outlets are combined by one bridge and removing the "Z" screws. Postfach DE-978 Wertheim Page of 7

Main line Fig. Functional process fig.... : Monitoring of progressive distributors: Bypass line left-side I II Bypass line right-side The lubricant flows from the main line through the right-side ring groove of piston III as well as the bypass line (right) and to the left side of piston I and moves it into its home position. The lubricant displaced by piston I is ejected via the left bypass line through outlet no.. As for instance due to soiling, the flow through a lubricant point line may be prevented. This will cause a piston to get blocked. By virtue of the forced control as depicted in figures up to, the other pistons will be stopped as well. Due to this configuration, the proportioning at all outlets of the distributor can be monitored by means of a sensor at one piston only. III Fig. Mounting note: I Fig. After shifting of piston I, lubricant flows to the left side of piston II and pushes it into its right-side home position. The displaced lubricant is ejected via outlet no.. The pistons are provided with an extremely small fitting clearance. Therefore, the pistons, after the dismantling of a distributor, must never be interchanged. Formula for calculating the lubricant available per lubrication point: After shifting of piston II, lubricant flows to the left side of piston III and pushes it into its right-side home position. The displaced lubricant is ejected via outlet no.. A progressive distributor allocates the delivered lubricant to the individual lubrication points in forced order. Due to the functional process as described herein, a safe proportioning is ensured. II The lubricant q i delivered to a lubrication point i can be calculated as follows q i = K i (K +K +K...) Q Fig. After shifting of piston III, lubricant flows to the right side of piston I and pushes it into its left-side home position. The displaced lubricant is ejected via outlet no.. The continuation of that process is evidenced in the scheme described. Q = lubricant delivered to the distributor, K i = distinctive number of the outlet i III Postfach DE-978 Wertheim Page of 7

Important information on this publication Reproduction, also in extracts, only permitted with the approval of the firm of EUGEN WOERNER GmbH & Co. KG. All the information in this publication has been examined for correctness with great care. Nevertheless, WOERNER cannot assume any liability for losses or damage resulting directly or indirectly from the application of the information contained in this publication. All products from WOERNER may only be used as intended and corresponding to the information in this publication. For products supplied with operating instructions, the additional directives and information contained in them are to be complied with. Materials deviating from those mentioned in this publication and the technical documents which further apply may only be poured into and processed in the appliances and systems manufactured and supplied by WOERNER by following agreement with and written approval by WOERNER. The safety and danger information stated in the safety data sheets of the substances used must be taken into account at all costs. Transportation of gases, liquefied gases, gases under pressure, vapours and liquids, the vapour pressure of which is more than 0, bar above normal atmospheric pressure (0 mbar) at the maximum admissible temperature, of easy inflammable or explosive media as well as transportation of foodstuffs is forbidden. Information on EU Directive 00/9/EC (RoHS) With Directive 00/9/EC of January 7, 00, for the limitation of the use of certain hazardous substances in electrical and electronic devices (RoHS) material bans come into effect from July 00 for electrical and electronic devices newly placed on the market for lead, cadmium, hexavalent chromium, mercury and brominated flame retardants. In its controls and switching devices, WOERNER only uses materials which fulfil the criteria of EU Directive 00/9/EC. To the extent that hexavalent chromium has been used as corrosion protection in the parts which we produce ourselves, it has already been replaced by other environmentally tolerable protective measures. The mechanical devices supplied by WOERNER are not affected by EU Directive 00/9/EC as they are appliances added or installed on "large-scale stationary industrial tools" (cf. EU Directive 00/9/EC, Annex IA). But as WOERNER is conscious of its responsibility towards the environment, we shall also use materials fulfilling the requirements of the Directive for devices not covered by EU Directive 00/9/EC as soon as they are generally available and their use is technically possible. Technical documents also valid for this product: B0 Operating instructions VP Postfach DE-978 Wertheim Page 7 of 7