Coolant (oil-based, water-soluble) Weak alkali-based cleaning fluid Cutting fluid Industrial water. Variations. Number of elements

Similar documents
Coolant (oil-based, water-soluble) Weak alkali-based cleaning fluid Cutting fluid Industrial water. Variations. Number of elements

Bag Filter. Latch mechanism. has been provided additionally. (Mechanism for protecting the cover from being removed)

Low Maintenance Filter

Low Maintenance Filter

FHM Series. Magnetic Separator. RoHS FH HOW

Compressed Air Cleaning Filter Series

Suction Filter with Case. Specifications. Fluid Operating pressure Operating temperature Cover/Case. Model/Rated Flow Rate. Model

Hydraulic Filters. Element (µm) nominal filtration. Port size. Micromesh 74, 105, 149 1/2, 3/4, 1, 1 1/4, 1 1/2, 2, 2 1/2, 3, 3 1/2, 4

Speed Controller with One-touch Fitting

Filtration efficiency: 99% or more

The filters for hydraulic fluids are used to protect each component in a hydraulic circuit. Port size. Micromesh 74, 105, 149

Speed Controller with One-touch Fitting

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

Standard Specifications. Model. Port (Bypass lubrication adapter)

Air Operated Valve Control Valve

25% reduction in volume * PB1013A/Air-operated type without foot

Added 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model

Speed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model.

Standard Specifications. Model. Port (Bypass lubrication adapter)

Two Hand Control Valve

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Air Suction Filter. Series ZF. Prevent from occurring vacuum equipment trouble due to dust from vacuum pad ZFA ZFB ZFC

RP-CS 2-98 CERTA-SEAL LIQUID BAG FILTERS WITH THE MATCHED PERFORMANCE DESIGN. Products

Filtration efficiency: 99% or more HEPO2element

Series AN /Series AMC

MATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS

LZB/LZC. Series LZB LZC. Electric Cylinder. Series. Series LJ1 LG1 LTF LC1 LC7 LC8 LXF LXP LXS LC3F2 E-MY LZB LZC

ALB900 Series. Standard Specifications. Model. Port (Bypass lubrication adapter)

Miniature Regulator Series ARJ310

Clean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ

Compact Proportional Solenoid Valve

Conventional specification. External Pilot air specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized.

Specifications. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

FLOW CONTROL VALVES F CONTROL VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.] Maximum flow rate L/min. Page

L L L L Connection up to M60 x 2 Nominal flow rate up to 850 l/min

Micro Mist Separator. Model. Note) 1 8, , , , , 1. Model/Free Standing Type. Model AMD (2B)JIS 10K FF flange

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure

Low Torque Rotary Joint

Specifications. Fluid Operating pressure Operating temperature Cover. Material. Model/Rated Flow Rate. Port size (Rc)

Mini Rotary Actuator/Rack & Pinion Style

Series AV2000/3000/4000/5000

How to Order. Nozzle. Nil Connection size N02 N03 F02 F H06 H08 H10 H07 H09 H11

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

Solenoid Pilot Operated Proportional Directional Control Valve

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Primary Pressure Regulating Valve Pressure Sustaining Valve Differential Pressure Regulating Valve

3-Way Ball Valve Type 23H

Soft Start-up Valve. AV2000/3000/4000/5000 Series

1. Preface For best results, please refer to this manual before using this product. 2. Safety precautions Model Precautions DFS-1 The maximum pressure

Specifications VH600. Ambient temperature and operating fluid temperature. Operating angle Lubrication. Semi-standard

Swing Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1

Specifications Valve. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

Compressed Air Cleaning Filter Series

Vacuum / Release Unit

Precision Clean Regulator

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

Multi-Circuit Rotary Block

CVE2/CVSE2 CVE3/CVSE3

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. 3 (Closed center) 3/4, 1 3 (Exhaust center)

Butterfly Valve Type 58 (PDCPD)

Compatible with an operating environment with coolants.

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Speed Controller with One-touch Fitting AS13 1F-M3 AS13 1F-M5. Specifications

Air Vent Valve Air Vent Valve with Vacuum Breaker

ACTIVAL Two-way Ball Valve with Threaded-end Connection

AR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication

Return-Suction Filters E 158 E 198 E 248. Tank top mounting Connection up to -20 SAE Nominal flow rate up to 66 gpm us

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Mini Rotary Actuator/Rack & Pinion Style

AS Series. 4.0 g. Weight: Approx. 27% lighter. Flow Rate Reproducibility. Larger Knob. Easy Identification of Product Type. 5.5 g.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Backflushing Filter AutoFilt RF3

Low Torque Rotary Joint

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Discharge rate* 2 L/min MPa (DE10-1) 37.8 MPa (DE10-7)

Specifications. Model/Rated Flow Rate. Accessory/Option. Differential pressure indicator

Coolant valve. SGC/SGH Series

Process Inline Filter Protective filter PLF2-9HF

Non-Contact Sensor for Workpiece Placement Verification

Series CYP. Clean rodless cylinder ø15, ø32. How to Order

Internet For latest information, PDF catalogs and operation manuals

CYLINDRICAL ROLLER BEARING CATALOG TIMKEN SMALL BORE METRIC SEALS CATALOG

Transmitters: Relay Valve VR4151/4152

Diaphragm Valves Type 15

Impulse Lubricator. Standard Specifications

Standard Specifications. Fluid Standard specifications. VH600 Ambient and fluid temperature Operating angle Lubrication. Optional Specifications

Speed Controller with Indicator

Speed Controller High Flow

[DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary. Document No:

3M TM Filter Housing 1BS-T/1BS-TW Series

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number

HVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview

KNOCK CYLINDERS CONTENTS ACTUATORS GENERAL CATALOG. Caution KNOCK CYLINDERS

Air Suction Filter / In-line Type With One-touch Fittings. Model ZFC ZFC ZFC ZFC ZFC ZFC ZFC ZFC051-03

This filter enables direct exhaust of air in a clean room! (Cleanliness class 4*: ISO ) (* Based on SMC s measuring conditions.

Transcription:

Bag Filter Series Optimum for the large flow filtration Easy maintenance Main operating fluids For other kinds of fluids, please contact SMC. With safety mechanism Employs proprietary SMC latch mechanism and band lock mechanism. Safe even in the event of erroneous operation. Latch mechanism The bag-stated element (made of non-woven cloth) makes it possible to filtrate the large flow with lower pressure drop. [ Series (one element included): Up to 400 L/min] Replacement operations are easy thanks to a built-in basket mechanism allowing element replacement outside the vessel. Coolant (oil-based, water-soluble) Weak alkali-based cleaning fluid Cutting fluid Industrial water Bag-stated element With a bag configuration, the aperture is wide and foreign matter is captured inside the element for easy removal. Furthermore, foreign matter captured inside the element will not spill over into the case interior or the surrounding area. FQ EB ES With band-lock mechanism Select from a wide range of filtration accuracy. Improved functionality and operability Renewed for easier use! Nominal filtration accuracy, 0, 2, 0, 00 µm [ Series(one element included)] Leg format changed to removable type, improved piping workability on bottom side. Easier handling thanks to lightweight band and hinge mechanism. Basket features hole for fluid release. Release of foreign matter to the outlet side is prevented. Weight: kg (Current model: 9 kg) 2% lighter than the current model Applies to A Variations Series Number of elements size ø90 x L440 ø90 x L770 Port size Rc2 4 B JIS0 K FF 6 B JIS0 K FF Maximum flow (Water, at P = 7 kpa) Approx. 400 L/min Approx. 200 L/min Approx. 2000 L/min 4

Bag filter offers excellent safety performance and ease of maintenance. With safety mechanism Employs SMC proprietary latch mechanism Prevents cover blowout in cases of erroneous operation. Latch mechanism can be replaced outside the vessel. Use of a built-in basket mechanism makes it possible to replace the element outside the vessel. Handle Basket Band system When cover is mounted Makes the work of tightening easy. Compared to a bolt tightening system with many places (between 4 and 6) that need to be tightened, this system is easy to use with only one place to tighten. Improved, easier handling thanks to lightweight band Easier handling with more lightweight band (Band weight: kg) With lock mechanism <Patent pending> Safe lock mechanism prevents band from coming off even in cases of erroneous operation under internal pressure. No-fluid-buildup structure Basket features hole for fluid release. Release of foreign matter to the outlet side during element replacement is prevented. Since there is no leftover fluid, there is no need to perform drainage operations. (The drain port of the current model has been eliminated.) Basket Hole for fluid release Lock mechanism Lightweight Band 2% lighter than the current model Weight: kg (Current model: 9 kg) Applies to A Piping operations are a breeze. With a removable leg system, carrying out piping operations at the fluid release port is easier. Example When removing legs from the main unit before attaching piping q Remove legs from the w Attach piping to fluid e Replace legs on the main unit and main unit. release port. attach piping to OUT port. OUT port Fluid release port 44

Series Variations of Bag Filters Available combination between an element and a vessel Vessel with one element 0. MPa type Vessel Standard products Vessel with three elements 0. MPa type Vessel with five elements 0. MPa type Standard elements P.47 Sub-element + Standard element P. Sub-element HEPO element P.6 Long service life element Branch type element P.7 PP (Polypropylene) bag element Filter paper element P.8 Note ) Combinations between standard or made-to-order elements and standard or made-to-order vessels are marked ( ) as above. Please contact SMC for delivery time as the and are produced upon receipt of order. Made to Order Types of Standard element Made-to-Order elements Bag element Sub-element + Standard element X46 Sub-element X8 HEPO element X49 Effective for extending the service life of a standard element Eliminates large foreign matter. P.47 P. P. P.6 High-performance filtration FQ EB ES Made-to-Order elements Long service life element X82 Branch type element X292 PP (Polypropylene) bag element X72 Filter paper element Long service life (Four to five times the filtration area compared with the standard elements) More compact vessel is possible. (Longevity for L440 is same as L770.) Applicable for strong alkali-based cleaning fluid P.6 P.7 P.7 P.8 (For precision X42 Suitable for filtering cutting fluids Note) Refer to pages to 8 for details on Made-to-Order elements and vessels. 4 A

Stable quality and reuse of fluid is possible thanks to filtration! Stable product Contributes to quality (Fewer defects, etc.) Application example Washing line Tank Pre-filter Final filter Tank [Filtration of cleaning fluid] The filter performs filtration of used cleaning fluid so it can be reused many times. (Thanks to cyclical filtration, the volume of waste fluid is reduced.) Prevention of problems in the line (Prevention of nozzle blockage, etc.) Maintenance example Two units used side by side [Reduction in length of time line is stopped for element replacement] Installing two bag filters means that one filter can always be used while the other is undergoing element replacement, meaning that the line does not have to be stopped for long periods of time for replacement of elements. Unit in use Less waste fluid Unit undergoing element replacement Cleaning basin- Cleaning basin-2 Rinsing New fluid supply Waste fluid IN IN OUT OUT Filter [Filtration of cleaning fluid] The filter is used to maintain a constant level of cleaning fluid. Processing line Unit undergoing element replacement Unit in use Tank Pre-filter Final filter Tank [Filtration of coolant] The filter performs filtration of used coolant so it can be reused many times. Filtration of industrial water Raw water Strainer Sand filtration Tank Pre-filter Final filter [Filtration of industrial water] The filter removes foreign matter from raw water so it can be used for manufacturing. 46

Three, five elements included (Made to Order) S Symbol S C L R included S A 20 E 00 B One element Vessel material Number of elements Symbol Bag filter Seal material FKM Number of elements pc included () pcs included () pcs included () Part number of element for replacement Specifications EJ 0S 00 symbol Bag Filter Series Material A 40 E 00 size Symbol size A ø90 x L440 B ø90 x L770 Symbol 20 40 60 size Symbol size 0S ø90 x L440 60S ø90 x L770 material (Polyester) Port size Port size Rc2 00(4 B )JIS0 K FF 0(6 B )JIS0 K FF For A For B Symbol Nil F L G F (Made to Order) Symbol With pressure gauge G ( MPa: Brass for wetted parts) Without pressure gauge Nil (with plug) Note that the differential pressure must be controlled strictly. None Companion flange Foundation bolt ( pcs) In the case of multiple options, indicate symbols in alphabetical order. Nominal filtration accuracy Note) Symbol Nominal filtration accuracy (µm) 00 00 0 02 2 00 0 00 00 Note) Nominal filtration accuracy refers to the filtration accuracy according to SMC criteria, and serves as a guideline for the particulates that can be filtered out. It does not mean that 00% of the particulates of the diameter shown can be filtered out. Made to Order (For details, refer to pages 74 to 78.) L770 L770 Model A-20 B-20 A-40 Note 7) B-40 Note 7) A-60 Note 7) B-60 Operating pressure Max. 0. MPa Common Note ) Maximum flow rate Approx. 400 L/min Max. 80 C (For with pressure gauge: 60 C or less) Approx. 200 L/min Approx. 2000 L/min Water-soluble coolant, Weak alkali-based cleaning fluid, Industrial water (Vessel material: ) Applicable fluid Oil-based coolant, Cutting oil (Vessel material: ) Cover 04 Case Note 6) [S/L] 04 Material Legs [C/R] Seal or FKM Port size Rc2 00(4 B )JIS0 K FF 0(6 B )JIS0 K FF Note ) Vessel Internal volume Weight 2 L kg L 6 kg 04 L 70 kg 6 L 90 kg 24 L 270 kg 07 L kg Note 4) Air release valve Handle for picking elements Davit for cover Basket integrated None MPa: Brass for wetted parts /4 B Ball valve (Brass) Part No.: AK-S Yes Material Polyester Nominal filtration accuracy, 0, 2, 0, 00 µm relacement differential pressure Note ) 0. MPa Number of elements element included elements included elements included Size ø90 x L440 ø90 x ø90 x L440 ø90 x L770 ø90 x L440 ø90 x Filtration area 800 cm 2 400 cm 2 400 cm 2 0200 cm 2 9000 cm 2 7000 cm 2 Accessories Note ) Conditions: Fluid = Water, Pressure drop 7 kpa, Nominal filtration accuracy 00 µm Confirm the conformity of the fluid to be used. Note ) Surface treatment No. 2D applies to the external surface of the vessel. (Scratches, scrapes, blotches and uneven color may be present as long as they do not interfere with function or performance.) The symbol refers to surface finishing of JIS G 40 cold rolled stainless steel sheet. Note 7) Note 4) For the series, this indicates cases where the with pressure gauge option has been selected. Note ) Control the element replacement so that the differential pressure does not exceed 0. MPa. Note 6) Parts other than the wetted parts are made of carbon steel and painted (silver). Note 7) Please contact SMC for delivery time as the and are produced upon receipt of order. 47 FQ EB ES B

Series Model Selection Step Step 2 Step Step 4 Selecting a Selecting the vessel filter model Checking operating conditions Determining the model and number of units Selection method Selection flow chart Selection example Step Checking operating conditions Fluid Pressure Temperature Flow rate Filtration accuracy Confirm that the specifications are within the appropriate range. Check the compatibility of fluid with element material [polyester]. To check the compatibility with main fluids, refer to Selection by Main Application on page 0. Check the compatibility of fluid with vessel material [stainless steel 04/ carbon steel]. To check the compatibility with main fluids, refer to Selection by Main Application on page 0. Check the compatibility of fluid with seal material [] or [FKM]. To check the compatibility with main fluids, refer to Selection by Main Application on page 0. Confirm that the temperature is 80 C or less. Checking operating conditions material Vessel material Seal material Temperature Check fluid/pressure/ temperature/flow rate/ filtration accuracy. Compatibility of fluid with polyester Compatibility of fluid with stainless steel 04/ carbon steel Compatibility of fluid with or FKM Consider Made-to-Order products. <<Operating conditions >> Fluid: Coolant (water-soluble) [Viscosity equivalent to water: mm /sec] Pressure: 0. MPa Temperature: 0 C Flow rate: 700 L/min Filtration accuracy: 0 µm Confirm that the specifications are within the appropriate range. Coolant (water-soluble) Compatibility with polyester: OK Compatibility with stainless steel 04: OK Compatibility with (FKM): OK 0 C 80 C or less: OK 0. MPa 0. MPa or less: OK 80 C or less Confirm that the pressure is 0. MPa or less. Pressure 0. MPa or less Consider special products. Possible range of pressure specifications up to.0 MPa OK 48

Model Selection Series Selection method Step 2 Selecting a vessel Selection flow chart Selection example q Calculating the number of elements Use the flow rate to calculate the number of elements. Required flow rate Recommended flow rate = Number of elements [Recommended flow rate per one element] 400 L/min (Pressure drop 7 kpa to 8 kpa) When viscosity rate is equivalent to water. For other viscosities, perform viscosity conversion. [Number of elements] Round up:.7 elements 2 elements When flow rate = 0 L/min or less, the compact filters [] [FQ] series are recommended. w Vessel type and number of units Choose a vessel that satisfies the number of elements obtained in step q. Step Selecting the filter model Selecting a vessel [Flow rate] (When viscosity rate is equivalent to water) 400 L/min or less element -20 unit 800 L/min or less 2 elements -20 2 units 200 L/min or less elements -20 units or -40 unit Calculate the number of elements. Required flow rate Recommended flow rate 700 L/min 400 L/min =.7 2 elements Choose the vessel type and number of units. 2 elements -20 2 units FQ EB ES Selecting the filter model q Selecting vessel material and seal material Select vessel and seal materials from among those compatible with the fluid used. Checking each item Vessel, Seal material Vessel: Seal: S-20 [Compatibility with fluid] Vessel: Seal: FKM L-20 For ( elements included) or ( elements included), carbon steel can be selected as the vessel material. Select vessel and seal materials based on compatibility with the fluid. Coolant (water-soluble) / : OK The model selected is the S-20. In this case, the L with FKM seal material can also be selected. w Selecting element size Select the element size when there is a large amount of contamination or frequent replacements. Flow rate does not change depending on element size. e Selecting filtration accuracy Select the required filtration accuracy depending on conditions. Filtration accuracy = Nominal filtration accuracy size [Standard life] Size: L440 A-20 Nominal filtration accuracy: µm -20-E 00 B [ service life (Longevity)] [.7 times longer life] Size: L770 B-20 When there is a large amount of contaminants in the fluid; When you want to reduce the frequency of replacements Filtration accuracy [Required filtration accuracy] to Nominal filtration accuracy: 00 µm to B-20-E 00 B Nominal filtration accuracy of, 0, 2, 0, 00 µm can be selected. Select the element size. With standard life, the model selected is the SA-20. When there is a large volume of contaminants in the fluid or when you want to reduce the frequency of replacements, select the SB with the L770 size element with.7 times longer life. Select the filtration accuracy. With a nominal filtration accuracy of 0 µm, the model selected is the SA-20-E 00 B. Step 4 Determining the model and number of units Determine the filter model and number units based on the results of Step 2 and Step. Select pressure gauge or other options as needed. Determining the model and number of units Based on the results of Step 2 and Step, 2 units of the SA-20-E00B are selected. 49

Series Selection by Main Application Material Compact filter [Other series] Vessel element included elements included elements included Note ) Field Fluid Material Filtration accuracy Vessel Seal Machine tools Washing equipment Others Coolant (water-soluble) Coolant (oil-based) Water-based cleaning fluid Weak alkali-based cleaning fluid Alcohol-based cleaning fluid Oil-based cleaning fluid Chlorine- / Fluorinebased cleaning fluid Strong alkali-based cleaning fluid Industrial water Cooling water Polyester Polyester Polypropylene (See Made to Order on P.7.) Polyester 0 to 0 µm to 2 µm 0 to 00 µm Flow Rate Characteristics (Initial Value) or FKM FKM Up to 0 L/min Up to 400 L/min Up to 200 L/min Up to 2000 L/min S S Compact filter S (, FQ) C C Compact filter (, FQ) Compact filter (, FQ) S L L X72 Select the element size (A: ø90 x L440; B: ø90 x L770) based on the amount of contaminants. The above is for guideline purpose only. Check the compatibility of fluid with product, seal and element material before operation. The flow rate is the appropriate flow rate at a viscosity equivalent to water. Note ) Please contact SMC for delivery time as the and are produced upon receipt of order. S L L X72 S L L X72 S S S A Test fluid: Water Liquid temperature: 7 C to 20 C (Room temperature) Test method: Per SMC test method Pressure drop (kpa) 0 20 0 7 Initial flow rate: Recommended setting range (Pressure drop: 7 to 0 kpa or less) µm, 0 µm 2 µm 0 µm, 00 µm 00 200 00 400 00 00 600 900 200 00 00 000 00 2000 200 Flow rate (L/min) Flow rate conversion based on viscosity conversion (with viscosity other than that equivalent to water) Example) Fluid: Coolant (oil-based) Kinematic viscosity: 20 mm 2 /sec Flow rate: 28 L/min ) Calculation of flow coefficient Obtain the flow coefficient from the viscosity conversion table. Kinematic viscosity: 20 mm 2 /sec Flow coefficient: 9% 2) Flow rate conversion Convert the flow rate when viscosity is equivalent to water using the flow coefficient obtained in step ). 28 L/min flow coefficient 9% = 00 L/min 00 L/min flow rate is necessary when viscosity is equivalent to water. After this, make a selection using the selection method. When making a selection, designate the flow rate as 00 L/min when viscosity is equivalent to water. Reference) The recommended flow rate for one coolant (oil-based) element at a kinematic viscosity of 20 mm 2 /sec is the recommended flow rate when viscosity is equivalent to water (400 L/min) x flow coefficient (9%) = recommended flow rate 80 L/min at a kinematic viscosity of 20 mm 2 /sec. Viscosity Conversion Table Kinematic (mm 2 /sec) viscosity (cst) Fluid indicator 400 High Equivalent to honey 200 00 20 Low Water, Coolant Coolant (water-soluble), (oil-based) Cleaning fluid Flow coefficient (%) 8 8 90 9 00 These relationships between fluids and kinematic viscosity are for guideline purposes only. Check the actual kinematic viscosity of fluid before using. Fluid viscosities shown are at room temperature (7 C to 20 C). Flow coefficient: When 00% of water flows at mm 2 /sec, the flow coefficient indicates that 8% flows at a kinematic viscosity of 00 mm 2 /sec. 0 Paint

Bag Filter Series Construction Air release valve Handle Bracket for V-band Inlet y Pin q t u Guide slit i r e Outlet w Component Parts/Replacement Parts No. Description Cover 2 Case Basket 4 6 7 8 V-band Legs (with bolt, nut, flat washer) O-ring Holder (with O-ring) Air release Fluid release Part No. -BT0 -BT02 EJ0S- EJ60S- -BA0 -OP0 (Set) -KT0 -KT02 -KT0 (Set) -KT04 (Set) Material Polyester FKM Polypropylene/ Polypropylene/ FKM Qty. Note ) A B A B Note ) Refer to on page 47 for the part of the model number. When replacing the t V-band, also replace the u O-ring at the same time. S L S L -40-60!0 Air release valve Inlet Pressure gauge w y u o q! t i!2 r e Component Parts and Seal List No. 2 4 6 7 8 9 0 2 Description Cover Case Basket Hinge bolt Eyenut Washer Parallel pin Lifter Handle O-ring Air release Gasket Fluid release Davit for cover Part No. BT-S BT-4S Refer to How to Order on page 47. AL-26S AL-27S AL-2S AL-24S AL-20S AL-2S Drain port Outlet Center bolt Nut Spring washer Retainer Material Qty. Note ) S/L C/R S/L C/R A-40 A-60 B-40 B-60 Polyester -40-60 S-40 C-40 S-60 C-60 L-40 R-40 FKM L-60 R-60 S-40 C-40 S-60 C-60 L-40 R-40 FKM L-60 R-60 Note ) Refer to on page 47 for the part of the model number. The leg parts are made of carbon steel. FQ EB ES

Series Dimensions -20 Approx. E (When the valve is opened.) D C B Air release Fluid release A Inlet B.C.D 96 6 Rc2 Inlet 27 8 Air release Davit Air release Fluid release () x ø20 M6 for foundation bolt Rc/4 Outlet 7 Rp/4 Gauge port in the inlet side () Rp/4 Gauge port in the outlet side () O.D 24 Rc2 Rc2 Outlet (mm) Model A B C D E SA-20 LA-20 SB-20 LB-20 62 9 72 0 820 0 98 02-60 x ø24 M20 for foundation bolt Fluid release -40 E (When the cover is lifted.) D C B Inlet B.C.D 422 Rc/4 00(4 B )JIS0 K FF A Inlet Air release 80 Davit O.D 48 20 0 Air release 70 x ø24 M20 for foundation bolt 7 Outlet Drain port Fluid release Drain port Outlet 2(2 B )JIS0 K FF Fluid release 289 (mm) Model A B C D E SA-40 CA-40 LA-40 RA-40 SB-40 CB-40 LB-40 RB-40 866 96 90 280 40 470 464 794 80 90 Davit for cover Gauge port in the inlet side () Gauge port in the outlet side () 2(2 B )JIS0 K FF 00(4 B )JIS0 K FF Inlet B.C.D 70 0 Outlet Drain port 90 47 2 E (When the cover is lifted.) D C B Rc/4 0(6 B )JIS0 K FF A Inlet 6 O.D 608 20 Air release Fluid release 70 Davit for cover Gauge port in the inlet side () Gauge port in the outlet side () Outlet 2(2 B )JIS0 K FF Drain port 2(2 B )JIS0 K FF 0(6 B )JIS0 K FF Model A B SA-60 CA-60 LA-60 RA-60 96 00 SB-60 CB-60 LB-60 286 80 RB-60 C 20 60 D 649 979 (mm) E 790 220

Bag Filter Series s Companion flange Flange øa P.C.D B øc T (mm) Part No. Flange dimension Material A B C D T C-40 Carbon F-86S R-40 steel 0(4 B ) S-40 Stainless F-87S L-40 steel 20 7.4 9 8 C-60 Carbon F-88S R-60 steel 0(6 B ) 280 240 66.6 2 22 S-60 Stainless F-89S L-60 steel Note) 2 pieces are required per filter unit. JIS0 K FF is used for this flange. 8 x ød Part No. Gasket øe øf Applicable model T2 Material E F T2 AL-79S -40 AL-80S -60 9 V # 600 220 67 Note) 2 pieces are required per filter unit. Hexagon bolt and nut Applicable Part No. Material G model AI-7S -40 60 AI-8S -60 70 Note) 6 pieces are required per filter unit. (mm) I Set of Components for Companion Flange Part No. F-90S F-9S F-92S F-9S Applicable model H G Flange Gasket (mm) Hexagon bolt C-40 F-86S R-40 AL-79S AI-7S S-40 F-87S L-40 C-60 F-88S R-60 AL-80S AI-8S S-60 F-89S L-60 H I 8 M6 x 2 46 M20 x 2. FQ EB ES Foundation bolt L R d L d S Hexagon nut Part No. -OP0 Applicable model -20 Nominal thread size d d M6 6 (mm) S L R (Approx.) (Approx.) L 40 7. 400 00-40 AI-S M20 20 0 90 40-60 Note) foundation bolts are required per filter unit. If ordering only foundation bolts, order bolts using the above part number.

Made to Order Series Made to Order s X46 Sub-element + Standard element X8 Sub-element X49 HEPO element X82 Long service life element P. Effective for extending the service life of a standard element P. Eliminates large foreign matter. P.6 High-performance filtration P.6 Long service life (Four to five times the filtration area compared with the standard elements) X292 P.7 Branch type element More compact vessel is possible. (Filtration area for L440 is same as L770.) X72 P.7 PP (Polypropylene) bag element Applicable for strong alkali-based cleaning fluid X42 P.8 Filter paper element Suitable for filtering cutting fluids (For precision Leg Material: Stainless Steel X47 P.8 4

X46 Effective for extending the service life of a standard element Sub-elements eliminate large foreign matter. Series Made to Order Please consult with SMC for details. Sub-element and Standard element equipped Sub-element Standard element It has a structure such that the spongiform filtration material, which is made of Polyvinylidene Chlorides, is in the form of a bag. It is then fixed by a ring inside the standard element. Refer to on page 47 for standard specifications. element included / elements included (Produced upon receipt of order.) Specifications Main applicable fluid Note ) Nominal filtration accuracy Note 4) Maximum flow rate Note ) replacement differential pressure Filtration material size Filtration area Coarse filtration 20 E B X46 E Note ) Without pressure gauge/without option: is not required to enter. Example) SA-20-E00B-X46, SB-40-E00X46 Sub-element/Ring Part No. size L440 L770 Sub-element (single part) EZS40S EZS0S Sub-element with ring EZS20S EZS0S Ring (single part) FZS0S Standard element (single part) EJ0S- EJ60S- A B Coolant (oil-based, water-soluble), Weak alkali-based cleaning fluid, Industrial water, 0, 2, 0, 00 µm (standard element), 00 to 000 µm (sub-element) Max. 80 C Max. 400 L/min Differential pressure 0. MPa Polyester (standard element), Vinylidene chloride (sub-element) ø90 x L440 ø90 x L770 800 cm 2 400 cm 2 X46 Note ) When changing from a standard product to one with X46 specifications, order a sub-element with ring. Since the model number will change when replacement is conducted, we ask that the customer manage the model number. When replacing only the element, order a sub-element (single part) and a standard element and attach the ring before use. Enter the symbol for nominal filtration accuracy in the part for the standard element. (Refer to page 47.) Note ) Fluids that cause corrosion, deterioration or expansion of the material used in the elements cannot be used. Note 4) Depends on the filtration accuracy (nominal filtration accuracy) of the element. Since sub-elements are specialized for coarse filtration, the nominal filtration accuracy is 00 µm or more. Note ) Conditions: Fluid = Water, Initial differential pressure 7 kpa, Nominal filtration accuracy 00 µm (standard element) (For other conditions, refer to Flow Rate Characteristics on page 0. Equivalent to standard element) Maximum flow rate is per one element. When there are three elements or five elements, multiply by or. Note ) FQ EB ES X8 Eliminates large foreign matter (00 µm or larger). Sub-element equipped Refer to on page 47 for standard specifications. Coarse filtration element included 20 B X8 / elements included (Produced upon receipt of order.) X8 Note ) Without pressure gauge/without option: is not required to enter. Example) SA-20-B-X8, SB-40X8 Note ) Note ) Sub-element/Ring Part No. size L440 L770 Sub-element (single part) EZS40S EZS0S Sub-element with ring EZS20S EZS0S Ring (single part) FZS0S When changing from a standard product to one with X8 specifications, order a sub-element with ring. Since the model number will change when replacement is conducted, we ask that the customer manage the model number. When replacing only the element, order a sub-element (single part) and attach the ring before use. Specifications Main applicable fluid Note ) Nominal filtration accuracy Note 4) Maximum flow rate Note ) replacement differential pressure Filtration material size Filtration area A B Coolant (oil-based, water-soluble), Weak alkali-based cleaning fluid, Industrial water 00 to 000 µm Max. 80 C Max. 400 L/min Differential pressure 0. MPa Vinylidene chloride ø90 x L440 ø90 x L770 800 cm 2 400 cm 2 Note ) Fluids that cause corrosion, deterioration or expansion of the material used in the elements cannot be used. Note 4) Specialized for coarse filtration, the nominal filtration accuracy is 00 µm or more. Note ) Conditions: Fluid = Water, Initial differential pressure 7 kpa (For other conditions, refer to Flow Rate Characteristics on page 0. Equivalent to standard element) Maximum flow rate is per one element. When there are three elements or five elements, multiply by or. B

Series B X49 High-performance filtration Optimum for filtration of precision machine fluids, precision cleaning fluids, etc. Effective for the grinding powders (For precision HEPO element equipped A cylindrical element in which the filter material made of P.G.P. (Polyester + Glass fiber) is sandwiched by a stainless steel mesh and pleated. Note 4) Fluids that cause corrosion, deterioration or expansion of the material used in the elements cannot be used. Note ) Specialized for precision filtration. The filtration accuracy indicates 98% of filtered particle size. Note 6) Conditions: Fluid = Water. For other fluids, maximum flow rate changes based on viscosity, etc. Maximum flow rate is per one element. When there are three elements or five elements, multiply by or. X82 Four to five times the filtration area (compared with the standard elements) Reduction in number of element replacements A cylindrical element in which the non-woven material made of PP (Polyprovddpylene) is sandwiched by a PET (Polyester) mesh and pleated. Note 4) Fluids that cause corrosion, deterioration or expansion of the material used in the elements cannot be used. Note ) The filtration accuracy is based on SMC criteria, and differs from the absolute filtration accuracy (filtration efficiency of 97% or more). Note 6) Conditions: Fluid = Water. For other fluids, maximum flow rate changes based on viscosity, etc. Maximum flow rate is per one element. When there are three elements or five elements, multiply by or. 6 Refer to on page 47 for standard specifications. Specifications Main applicable fluid Note 4) Nominal filtration accuracy Note ) Maximum flow rate Note 6) replacement differential pressure Filtration material size Filtration area Specifications Main applicable fluid Note 4) Nominal filtration accuracy Note ) Maximum flow rate Note 6) replacement differential pressure Filtration material size Filtration area High-performance filtration element included 20 Z 00 B X49 / elements included (Produced upon receipt of order.) Z 00 Note ) Without pressure gauge/without option: is not required to enter. Example) SA-20-Z00B-X49, SB-40-Z00X49 A B Coolant (oil-based, water-soluble), Weak alkali-based cleaning fluid, Industrial water µm Max. 80 C Max. 00 L/min Max. 200 L/min Differential pressure 0. MPa Polyester/Glass fiber ø86 x L2 ø86 x L642 600 cm 2 600 cm 2 Long service life element equipped Large filtration area Refer to on page 47 for standard specifications. element included 20 Z 00 B X82 Note ) Without pressure gauge/without option: is not required to enter. Example) SA-20-Z00B-X82, SB-40-Z00X82 A B Coolant (oil-based, water-soluble), Weak alkali-based cleaning fluid, Industrial water 0 µm Max. 80 C Max. 00L/min Max. 200L/min Differential pressure 0. MPa Polypropylene/Polyester ø86 x L2 ø86 x L642 9400 cm 2 2400 cm 2 X49 /-Fixing Component Part No. HEPO element -fixing component size (single part) included / included Note ) L440 EZ20AS -OP0 -OP0 L770 EZ0AS When changing from a standard product to one with X49 specifications, additionally order a HEPO element (single part) and an element-fixing component. Since the model number will change when replacement is conducted, we ask that the customer manage the model number. When replacing only the element, order a HEPO element (single part). Note ) set is required per element. Ex.) When using elements, order sets. / elements included (Produced upon receipt of order.) Z 00 X82 /-Fixing Component Part No. Long service life -fixing component size element (single part) included / included Note ) L440 EZD80AS-00 -OP0 -OP0 L770 EZF70AS-00 When changing from a standard product to one with X82 specifications, additionally order a long service life element (single part) and an element-fixing component. Since the model number will change when replacement is conducted, we ask that the customer manage the model number. When replacing only the element, order a long service life element (single part). Note ) set is required per element. Ex.) When using elements, order sets. Note ) Note ) Note ) Note )

Made to Order Series X292.8 times the filtration area (compared with the standard element) Filtration area is the same for short size elements (L440) and long size (L770). More compact vessels are possible. Branch type element equipped Two-bag construction made of polyester non-woven material. X72 PP (Polypropylene) bag element equipped Polypropylene filter material can be used with a wide variety of fluids. Applicable for strong alkali-based cleaning fluid Refer to on page 47 for standard specifications. Large filtration area Specifications A Main applicable fluid Note 4) Coolant (oil-based, water-soluble), Weak alkali-based cleaning fluid, Industrial water Nominal filtration accuracy Note ), 0, 2, 0, 00 µm Max. 80 C Maximum flow rate Note 6) Max. 400 L/min replacement differential pressure Differential pressure 0. MPa Filtration material Polyester size ø90 x L440 Filtration area 00 cm 2 Note 4) Fluids that cause corrosion, deterioration or expansion of the material used in the elements cannot be used. Note ) Depends on the filtration accuracy (nominal filtration accuracy) of the element. Note 6) Conditions: Fluid = Water, Initial differential pressure 7 kpa, Nominal filtration accuracy 00 µm (standard element) (For other conditions, refer to Flow Rate Characteristics on page 0. Equivalent to standard element) Maximum flow rate is per one element. When there are three elements or five elements, multiply by or. Note ) Without pressure gauge/without option: is not required to enter. Example) SA-20-E00B-X292 A 20 E B Refer to on page 47 for standard specifications. Polypropylene element included 20 E B X72 E X292 Note ) Note ) Part No. Branch type element Basket size (single part) L440 EJS- Note ) -BT0 When changing from a standard product to one with X292 specifications, additionally order a branch type element (single part) and a basket component. Since the model number will change when replacement is conducted, we ask that the customer manage the model number. When replacing only the element, order a branch type element (single part). Note ) Enter the symbol for nominal filtration accuracy in the part. (Refer to page 47.) / elements included (Produced upon receipt of order.) X72 Note ) FQ EB ES Note ) Without pressure gauge/without option: is not required to enter. Example) SA-20-E00B-X72, SB-40-E00X72 Note ) Nominal filtration accuracy Symbol Nominal filtration accuracy (µm) 00 00 00 Part No. PP (Polypropylene) size bag element (single part) L440 EJ0S-X0 Note ) L770 EJ60S-X0 Note ) When changing from a standard product to one with X72 specifications, order a PP (Polypropylene) bag element. Since the model number will change when replacement is conducted, we ask that the customer manage the model number. When replacing only the element, order a PP (Polypropylene) bag element (single part). Note ) Enter the symbol for nominal filtration accuracy in the part. Specifications Main applicable fluid Note 4) Nominal filtration accuracy Note ) Maximum flow rate Note 6) replacement differential pressure Filtration material size Filtration area A B Strong alkali-based cleaning fluid, Coolant (oil-based, water-soluble), Weak alkali-based cleaning fluid, Industrial water,, µm Max. 80 C Max. 400 L/min Differential pressure 0. MPa Polypropylene ø90 x L440 ø90 x L770 800 cm 2 400 cm 2 Note 4) Fluids that cause corrosion, deterioration or expansion of the material used in the elements cannot be used. Note ) Depends on the filtration accuracy (nominal filtration accuracy) of the element. Note 6) Conditions: Fluid = Water, Initial differential pressure 8 kpa, Nominal filtration accuracy µm (standard element) (For other conditions, refer to Flow Rate Characteristics on page 0. Equivalent to standard element) Maximum flow rate is per one element. When there are three elements or five elements, multiply by or. 7 B

Series X42 Optimum for filtration of cutting or grinding oil Large filtration area makes it suitable for filtrating fluids containing highly dense contaminants. Filter paper element equipped A cylindrical element with a cotton-made filter inside and a pleated material on the outside for reinforcement. Note 4) Fluids that cause corrosion, deterioration or expansion Specifications of the material used in the elements cannot be used. Only oil-based fluids can be used. Main applicable fluid Note 4) Note ) Depends on the filtration accuracy (nominal filtration accuracy) of the element. Nominal filtration accuracy Note ) Note 6) Conditions: When fluid has a kinematic viscosity of 6 mm 2 /sec (equivalent to turbine oil VG6). Maximum flow rate Note 6) For other fluids, maximum flow rate changes based replacement differential pressure on viscosity, etc. Filtration material Maximum flow rate is per one element. When there size are three elements or five elements, multiply by or. Filtration area Refer to on page 47 for standard specifications. element included 20 Z 00 B / elements included (Produced upon receipt of order.) For cutting/grinding oil Z 00 Note ) Without pressure gauge/without option: is not required to enter. Example) SA-20-Z00B-X42, SB-40-Z00X42 X42 A B Coolant (oil-based), Lubricating oil 0 µm Max. 80 C Max. 00 L/min Max. 200 L/min Differential pressure 0. MPa Cotton ø86 x L2 ø86 x L642 8900 cm 2 800 cm 2 X42 Note ) Note ) /-Fixing Component Part No. Filter paper element -fixing component size (single part) included / included Note ) L440 EJ0S-00X6 -OP0 -OP0 L770 EJ60S-00X6 When changing from a standard product to one with X42 specifications, additionally order a filter paper element (single part) and an element-fixing component. Since the model number will change when replacement is conducted, we ask that the customer manage the model number. When replacing only the element, order a filter paper element (single part). Note ) set is required per element. Ex.) When using elements, order sets. X47 Leg material: Legs made of stainless steel can be used. Refer to on page 47 for standard specifications. A 20 E B Note ) Without pressure gauge/without option: is not required to enter. Example) SA-20-E00B-X47 X47 Note ) Note ) B Legs (Material: ) Legs Part No. Part no. Material Included parts -OP02 Mounting bolt/nut/flat washer When changing from a standard product to one with X47 specifications, order the part numbers above and replace only the legs. Since the model number will change when replacement is conducted, we ask that the customer manage the model number. 8 Specifications Operating pressure Common Maximum flow rate Note ) Main applicable fluid Note 4) Vessel Cover Material Case Legs Port size Internal volume Weight Filtration material Nominal filtration accuracy Note ) replacement differential pressure Number of elements size A B Max. 0. MPa Max. 80 C Max. 400 L/min Coolant (oil-based, water-soluble), Weak alkali-based cleaning fluid, Industrial water 2 L kg 04 04 Rc2 L 6 kg Polyester, 0, 2, 0, 00 µm Differential pressure 0. MPa ø90 x L440 ø90 x L770 Filtration area 800 cm 2 400 cm 2 Note ) Conditions: Fluid = Water, Initial differential pressure 7 kpa, Nominal filtration accuracy 00 µm (standard element) (For other conditions, refer to Flow Rate Characteristics on page 0. Equivalent to standard product.) Note 4) Fluids that cause corrosion, deterioration or expansion of the material used in this filter and elements cannot be used. Note ) Depends on the filtration accuracy (nominal filtration accuracy) of the element.

Series Specific Product Precautions Be sure to read this before handling the products. Refer to back page 0 for Safety Instructions and the Operation Manual for details. Please download the Operation Manual via SMC website, http://www.smcworld.com Model Selection/Design Do not select a model exceeding specification ranges and carefully consider the purpose of use, required specifications and operating conditions such as fluid, pressure, flow rate, temperature and environment. Mishandling may lead to an unexpected accident. Warning. Operating pressure Do not use the product beyond the operating pressure range. Do not use in locations where peak pressure exceeds the operating pressure due to water hammer, surge pressure, etc. 2. Do not use the product beyond the operating temperature range. Do not use at temperatures at or above the boiling point of the fluid.. Fluid Use the product for filtering coolant (oilbased or water-soluble), weak alkalibased cleaning fluid or industrial water. Never use the product with gases. Do not use the product with corrosive fluids. Do not use the product with fluids which will likely cause the expansion and deterioration of seals, O-rings or the element. Some fluids can deteriorate a seal or an O-ring, and have an affect on the filter function, causing leakage. The wetted parts of the pressure gauge is made of brass. Check the compatibility with fluid in use. 4. Operating environment Do not use in operating conditions or environments where changes in color or deterioration of material due to corrosion occur. Do not use this product in a place where shock or vibrations occur. Caution. Pressure drop ( P) Use the product with a flow which has an initial pressure drop which will become 0 kpa or less. The pressure drop fluctuates depending on operating conditions. Since the pressure drop is one of the factors indicating filter characteristics, use the filter by setting a controlling standard. 2. Installation space Arrange the necessary space for inspection, before installing and piping the product. [Maintenance work space] Above vessel (for removal of basket during element replacement)... At least 40 mm of space above vessel Around band (for removal of band during element replacement)... At least 0 mm of space around band Applies to Installation and Piping Caution. Use the product with a circuit having lesser fluctuation to the filter caused by pressure or flow. (Refer to Fig..) Air release circuit Pump Bag filter Fluid Tank release valve Foundation bolt Fig. Example of cyclical filtration circuit 2. Use the product in a circuit where no backflow occurs in the filter. If any backflow occurs, take appropriate measures, such as installation of a non-return valve. The riser piping at the outlet of the filter may also cause backflow. So, take appropriate measures shown above.. Firmly fix the bottom to the ground using foundation bolts, etc. 4. Connect the valves or fittings suited to the operating conditions by checking the size of each connection port. During connection work, make sure that powder from the piping screws or seal material does not get into the interior of the piping. Prior to operating, flush the piping line and check for abnormalities, such as fluid leakage.. Firmly fix the piping to the mounting frame using a saddle, etc., to avoid vibration or force caused by the weight. 6. During element replacement, it is necessary to release fluid from the vessel. Be sure to connect the pipe to the fluid release port so that fluid releasing work can be absolutely performed. 7. Pipe so that air releasing work can be absolutely performed. The air releasing work can be done firmly if you make the piping in order to flow a small flow constantly into a tank by resin tubing, etc. from the air release valve. (Refer to Fig. 2.) Tubing To a However, because the Air release tank pump is in a high position, idling sometimes valve occurs during re-start. Take measures such as releasing the air in a high position, etc. Fig. 2 Air release circuit Operation Warning. Never loosen the V-band under pressurized conditions. Operation Caution. Releasing the air When applying pressure for starting a pump, etc., be sure to release the air by opening the air release valve Air release valve on the top. (Refer to Fig..) Fig. Releasing the air 2. When operating When applying pressure for starting a pump, etc., confirm that each connecting parts are completely sealed. If any abnormality is found, such as fluid leakage, stop the product immediately and locate the possible cause of the failure. Resume operation after taking appropriate measures to stop the fluid leakage by replacing the O-rings or additionally tightening the fittings, etc. Maintenance Warning. Failure to observe the procedure will likely cause fluid leakage or removal of a cover, which may lead to an unexpected accident. (Follow the procedure in the operation manual.) 2. Confirm that the line has stopped and pressure has been reduced to zero before performing maintenance work. Caution. Timing of element replacement When the time has come to replace the element, replace it with a new element immediately. = Timing of element replacement = When pressure drop has reached to 0. MPa. 2. replacement work Carry out element replacement work based on the procedure in the operation manual. Mishandling could lead to malfunction or damage the machinery and equipment. Replace the elements only after confirming that the pressure is zero. The parts used for tightening the cover (V-band, etc.) must be properly positioned after replacing elements.. Cleaning each component During element replacement, in order for firm sealing to take place, clean the sealing surface of the seal and/or remove the paint which is left on the tightened parts of the cover or the thread parts. 4. Replacing seals Replace the deteriorated or expanded O-ring, gasket holder assembly or other seals. Also, replace the seal after it has been used for one year or when fluid leakage occurs.. Parts used for tightening the cover If a part used for tightening the cover (V-band, etc.) is deformed or the threads are galled, it must be replaced. 6. Temperature When operating at high temperatures (40 C to 80 C), there is danger of burns, etc. Confirm that the surface temperature of the filter or the parts for operation (V-band, element, etc.) are 40 C or less, to prevent a burn from occurring. 9 FQ EB ES