Covers for Cast Iron or Aluminum Device Boxes

Similar documents
WP Plugs and DS Receptacles For FS and FD Cast Device Boxes

Hazardous Factory Sealed Control Devices

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Weather Protective Devices

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

Condulet Cast Device Boxes and Covers Application and Selection

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

EDS / EFS Series Control Stations

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

Condulet Single Gang Cast Device Boxes With and Without Mounting Lugs for Threaded Rigid and IMC Conduit

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

Control Stations Hazardous and Non-Hazardous

Junction Boxes Hazardous and Non-Hazardous

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Cover more applications with the most versatile Weatherproof Covers on the market

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Spring-loaded cover seats against neoprene gasket.

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Plugs and Receptacles: Hazardous Location

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

EBMC Combination Line Starters and Enclosures

Non-Metallic Weatherproof Boxes, Covers and Lampholders

Control Circuits Connectors Type SK & SKW Overview

Motor Starters Hazardous and Non-Hazardous

Condulet Conduit Bodies and Outlet Boxes Hazardous

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

Control Circuit and Industrial Interlock

W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Lighting and Power Distribution Panelboards

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Contender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw.

Enclosures. Section E

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Mulberry Metal Products Seattle Stock Sheet

Arktite Plugs, Receptacles, and Connectors

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous

Hazardous Duty Applications

Electrical Accessories

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.

Residential LEW ELECTRIC FITTINGS COMPANY R C P. serving the electrical industry since Series RRPSeries SWBSeries RCFBSeries

Circuit Breakers Hazardous

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

Cat Description Finish. 1 Hole Plug Gray /4 Hole Plug White /4 Hole Plug Bronze /4 Hole Plug Gray 10 30

Product Information. Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. MD2SR Interlocked Switched Receptacle

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

Wallplates & Weather Protective Covers

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Applications. Illustrated Features

Design Standard. Purpose: Design Standard:

Watertight Wiring Devices. A complete collection of watertight devices for demanding industrial environments wetguard

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

East Central College

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223

Plastic Ceiling Receptacle Lampholders

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

7S Series. Standard Finishes Gray hammer epoxy/polyester pow-der coat. Compliances UL Listed. NEC OSHA

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Plugs and Receptacles Industrial Heavy Duty Non-Hazardous

COMBINATION COVER & CARPET FLANGE

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Push Button. Rocker Arm

Division 2 Contender Series Factory Sealed Control Stations

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

AE Series Pin and Sleeve Plugs, Connectors and Receptacles Weatherproof 600 Vac, 250 Vdc. Pressure Wire Terminals.

Options. Pole and Arm. Suitable for wet locations

DIN Rail Mounting Bracket

Plugs & Receptacles. Section P

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors

SECTION MOTOR REQUIREMENTS for HVAC

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Aluminum Conduit Bodies, Covers and Gaskets For Rigid Conduit & IMC.

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

Transcription:

Single Gang Blank cover for enclosing splices and taps where device not used. Sheet DS100 Flush Sheet steel DSS100 For GFI receptacles. Sheet steel DS23 GFI For square handle general use snap or toggle switches unguarded. Sheet steel DS32 Sheet DS32 SA Blank cover with gasket for enclosing splices and taps where device not used. or Flush Cast DS100G F plug receptacle requiring 1 5 /8" opening diameter. Sheet steel DS35 For square handle general use snap or toggle switches guarded. with gasket DS32G Sheet steel DS52 DS21 DS21G For duplex convenience receptacles. Sheet steel DS23 Sheet DS23 SA Flush Sheet steel DSS23 and 3-pole, 2-wire grounding type round flush receptacles. Opening diameter 1 7 /16". Sheet steel DS21 Sheet with gasket DS21 SA DS21G and 3-pole, 2-wire grounding type duplex convenience receptacles. Gasket included. DS23G Adapter plate for mounting WLRS/ WLRD covers to flush device boxes. Description Cat. # Flush Device Adapter WLRA1 Also can be used to mount all covers with four corner screws listed see pages 37, 39, 40, 41, 42 and 43 to flush device boxes. See page 42 for receptacle specifications and listings of complete receptacle/cover combinations. Must be used with a wet locations rated wiring device. 39

Covers for Cast Iron or Aluminum Device Boxes Single Gang - Raintight Covers (Gasket Included) operation Copper-free DS181 operation. With hole for lock Die cast DS185 operation. Marked handle Cast DS128 40

Raintight Single Gang - Switches and Motor Control Push Button For manual motor starting switches. Fits FS and FD boxes. Takes Westinghouse switches MST01 (1-pole) and MST02 (2-pole). operation Feraloy DS199 Furnished with buttons for operating motor control push button switches. Push Buttons Description No. Color Material Cat. # Button (normally open) marked START 1 Green Feraloy DS171F ➀ Button (normally closed) marked STOP 1 Red Feraloy DS171G ➀ Button (normally open) marked 1 Green START and button (normally closed) 1 Red marked STOP Feraloy DS171 ➀ Description No. Color Material Cat. # Two push button 2 Black Feraloy DS171J ➀ ➀ If desired, markings on indicating plates may be added to catalog number. Select from the list of standard markings below: HAND CLOSE OFF AUTO. UP RUN EMER. DOWN JOG FORWARD START RESET REVERSE STOP TRIP OPEN ON TEST LGT. ON Heavy duty motor control push button switch No. of Buttons Normal Positions Cat. # 1 1 circuit universal ED11 2 2 circuits universal ED12 Two universal contact blocks, must be wired as two circuits, with one normally open and one normally closed. DS Covers use the switches shown in the list below. Cover Takes Switch Cover Takes Switch DS171 ED12 DS171F ED11 DS171G ED11 DS266 ED12 DS265 ED11 41

Covers for Cast Iron or Aluminum Device Boxes Weatherproof Single Gang - DS Receptacles and WP Plugs Applications: WP plugs and DS receptacles are used: Wherever dust, dirt, moisture and corrosion are a problem Outdoors or in locations where frequent washdowns occur, as in dairies and food processing plants Features: DS receptacle housings are used: With FS and FD cast device boxes, either surface mounted or installed flush in a wall With single gang, two gang tandem and multiple gang boxes having individual cover openings A threaded cap which effectively seals housing when not in use WP plugs include: A molded Neoprene hood with integral sleeve to seal the cord entrance An ring which clamps the hood to receptacle housing face, to complete watertight seal when plug is in use Certifications and Compliances: UL Standards: 498; 514A NEMA/EEMAC: WD-1; WD-5 CSA Standard: C22.2 No. 42* *Compliance. Standard Materials: Receptacle housings: body ; cap copper-free Plug exteriors: hood Neoprene; fastening ring copper-free Standard Finishes: Feraloy electrogalvanized and acrylic paint Copper-free natural Neoprene natural (black or yellow) Electrical Rating Ranges: 15 amperes, 125 volts 20 amperes, 125, 250 volts DS Receptacle housings WP Plugs Grounding Type Receptacles For Plugs with U shaped or Round Grounding Contacts Rating Cover With Recept. Cat. # Diagram Style 15 amps 125 volts DS96* 2-wire, CC Replacement receptacle Plug Cat. # Diagram Cord Dia. 3-pole WP820.500 to NEMA: 5-15R NEMA: 5-15P 20 amps 125 volts DS222 2-wire, 3-pole WP832.500 to NEMA: 5-20R NEMA: 5-20P 20 amps 250 volts DS290 2-wire, 3-pole WP930.500 to NEMA: 6-20R NEMA: 6-20P Third pole grounded. *Compliance For listing of typical FS cast devices boxes, see pages 23 and 24. Repl. Recept. Cat. # CC55 CC71 CC90 42

Single Gang - Pilot Light Covers, Extensions and Adapters For pilot light units (furnished with jewels) Jewel Description Material Color Cat. # Sheet steel Red DS24 Pilot light (with transformer), FD only Circuit Lamp Voltage Base Watts Cat. # 440 Candelabra 6 C333 Transformer 50 60 cycle, 440 / 110 volts. FS flush mounting adapter (can be used with multi-gang bodies having individual cover openings. Furnished with gasket and screws) Mtg. Style Cat. # Wall FS031 For pilot light units (furnished with jewel and gasket). Description or flush Material Feraloy Red Jewel Color Cat. # DS24G EXF Extensions (takes covers and flush rectangular wiring devices, or plug receptacles with housings) Ext. Depth Cat. # 1" EXF11 2 1 /2" EXF21 Gaskets for use between device boxes and covers. Material Cat. # Neoprene GASK91 Not recommended as watertight. Pilot light unit (without transformer) Circuit Lamp Voltage Base Watts Cat. # 110 Candelabra 6 C3310 43