The easiest and fastest way to select and specify the right fuse

Similar documents
Specification made simple for selective coordination in a compact size

Products for enhancing electrical safety and reliability

Now - Up To 400A Mains!

The easiest and fastest way to select and specify the right control circuit fuse

Low voltage, branch circuit fuses

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

Low Voltage, Branch Circuit Rated Fuses

Compact Circuit Protector (CCP) Application Note

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Fuseology. Dual-Element, Time-Delay Fuse Operation

Advanced Guide To Understanding Assembly Short-Circuit Current Rating WITH ENGINEERING SOLUTIONS AND OVERCURRENT PROTECTION DEVICES TO ENHANCE SCCR

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

overvoltage solutions

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

CUBEFuse. CUBEFuse catalog numbers (amps)

BUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

HVAC and Refrigeration Circuit Protection Solutions. Compact and safe HVAC/R circuit protection

Bussmann series Quik-Spec Coordination Panelboard

UL Recognized power distribution blocks

Low-Peak fuses offer the industry s most advanced circuit protection

Quik-Spec Coordination Panelboard

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

A case study in solving SCCR issues

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

6.3 mm reverse quick connect

BH-1 modular fuse blocks, 700 V, 400 A

Electrical safety and reliability: Selective coordination. Protect with selective coordination

Class J modular ferrule and knifeblade fuse blocks

Electric vehicle auxiliary fuses 500 Vdc, A

Downtime Reduction, Workplace Safety & Code Compliance SERVICES TO INCREASE YOUR PRODUCTIVITY THROUGH PROTECTION

Industry s most comprehensive medium voltage circuit protection

Compact Circuit Protector (CCP)

Electrical Safety and Reliability: Short-Circuit Current Rating (SCCR) Equipment SCCR made easy

Bussmann. Circuit Protection Solutions

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

N0N A 250V One-Time Class H Fuse

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

Volume 4C: Circuit Protection Bussmann series solutions

Effective December 2015 Supersedes September 2013

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Selective Coordination

Ferrule fuses. High Speed Fuses

Quik-Spec Electrical Gear

Low-Peak 600V Class RK1

General Data Dimensions (Inches) Bussmann

Quick reference guide to blocks, switches, holders and fuseclips for Bussmann series fuses

Engineering Dependable Protection

www. ElectricalPartManuals. com Engineering Dependable Protection

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

Quik-Spec Coordination Panelboard

Harmonization of IEC and North American Safety Standards

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

WARNING Personnel and property must be protected against the consequence of component break-down internally in the frequency converter.

Reduce Downtime With Quick Access to the Right Replacement Fuse

Selecting Protective Devices SPD. Electrical protection handbook. Based on the 2017 NEC

Selective Coordination Enforcement:

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

Assembly not available for new installations.

Equipment Protection. Transformers 600V or Less

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

PT Medium voltage fuses for potential and small power transformers

Fuse technology. Application Guide

Compact Circuit Protector

Equipment Protection. Listed or Labeled Equipment. Panelboards. Branch Circuit Protection HVAC. Appliances. Supplementary Protection

Selection Guide Motor Control Device Solutions

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

Overcurrent protection fundamentals

Photovoltaic System Overcurrent Protection

up to 30A limited by conductor size Operating and storage temperature:

Quik-Spec. Section Contents

Compact Circuit Protector (CCP)

footprint of traditional fusible switches

Compact Circuit Protector (CCP)

Photovoltaic System Overcurrent Protection

Compact Circuit Protector (CCP)

Medium Voltage Metal-Enclosed Switches

Ampgard The name motor applications rely on

Leading the way in new innovative circuit protection

Compact Circuit Protector (CCP)

Selecting Protective Devices

Medium Voltage Metal-Enclosed Switches

Bussmann Services & Application Guide

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

Electrical Safety and Overcurrent Protection

Fuse Accessories. Bussmann - Fuse Holders. Fuse Holders

Applying Interrupting Rating: Circuit Breakers

North American Power Fuses

Volts: 600V Amps: up to 30A limited by conductor size Withstand: 200kA RMS Sym. Operating and storage temperature:

Applying Interrupting Rating: Circuit Breakers

Selective Coordination

Medium Voltage Fuses. Industry s most comprehensive medium voltage circuit protection

Transcription:

Fuses Made Simple BUSSMANN SERIES The easiest and fastest way to select and specify the right fuse

Fuse selection made simple

Fuses Made Simple with Bussmann series fuses Three tiers of protection help speed up specification and selection 2 Each tier of protection offers distinct levels of performance benefits. Ulitimate protection The best worry-free protection in virtually any application. Unique dual-element construction delivers a powerful combination of all performance options in one fuse - fast short-circuit protection, current limitation, and time-delay performance with up to 00 ka interrupting ratings. Advanced protection Application specific protection for sensitive devices and critical components or motors and transformers. Choose between fast short-circuit, current limiting performance or energy efficient, current limiting, time-delay performance based on the application. Featuring 200 ka interrupting ratings. Basic protection Basic single-element protection for service, feeder and branch circuit applications. Featuring up to 00 ka interrupting ratings. Four fuse families make fuse selection and replacement easy Each fuse family is categorized by key protection characteristic and performance benefits. Ulitimate protection Low-Peak (yellow) - 50% more protection than any other listed fuse * Advanced protection Fusetron (green) - 2% more energy efficient *** and the best time-delay performance Limitron (black) - 0x better current limitation than basic circuit breakers or fuses ** Basic protection General purpose (gray) - Basic circuit protection QuikShip Service - get the fuse you need, when you need it The Bussmann series QuikShip Everyday Service assures the most common part numbers are in stock and ship within 24 hours. In fact, 90% of our orders are shipped the same day. Emergency and after-hours orders are possible with Bussmann series QuikShip Emergency Service. Orders are taken 24 hours a day, 65 days a year and product can be placed on the next flight out. Call 4-995-42. * 50% higher IR (00kA) than any other UL and CSA Listed Fuse. Includes Class J, L and R fuses. ** Does not include current limiting circuit breakers or current limiting fuses. Protection determined by comparing published values for let through for Class CC, J, R, and T fuses versus a symmetrical RMS waveform at 200kA. *** Test results are based on weighted sales volume of FUSETRON and Ferraz Shawmut (Mersen) fuses by selected amp and volt rating combination. Next leading brand refers to Ferraz Shawmut based on third-party fuse market share data for a twenty-seven month period (July 2008 through September 200).

Three tiers of protection Follow the tiers of protection to find the right level of protection for your application The four Fuses Made Simple families are grouped into three tiers of protection to meet the needs of any application. 2 When you move up to the next level of protection, you can get enhanced performance compared to the fuses in the lower tier. For example, Fusetron fuses can replace your general purpose fuses in branch circuit applications and Low-Peak can be used in any application, giving you worry free, enhanced performance. 2 Ultimate protection Industry s only UL and CSA listed fuse with up to 00 ka interrupting rating Combines Limitron fast short-circuit protection and Fusetron dual-element time-delay for ultimate protection Best in class Arc Flash Protection in all applications reduces hazard to personnel Reduce inventory up to % by replacing General Purpose, Limitron, and Fusetron with Low-Peak fuses Consistent 2: selective coordination ratios for all Low-Peak fuses Advanced protection Dual-element time-delay allows for superior protection of motors and transformers 2% more energy efficient than the next leading brand *** Best time-delay performance 200 ka interrupting rating allows for use in virtually any application Fast short-circuit protection of critical devices or loads Arc flash protection in selected applications reduces hazard to personnel 0x better current limitation on average compared to basic circuit breakers and fuses ** Basic protection Meets basic requirements for service, feeder, and branch circuit protection 4

Four fuse families Low-Peak Delivers 50% more protection than any other listed fuse * Ultimate protection for any application Industry s only UL and CSA listed fuse with a 00 ka interrupting rating allows for simple, worry-free installation in virtually any application Fast short-circuit protection and dual element, time-delay performance for ultimate protection Consistent 2: coordination ratios for all Low-Peak fuses make selective coordination easy Broad fuse family including Class CC, J, L, and R Fusetron 2% More Energy Efficient *** and the Best Time-Delay Performance *** Advanced protection and save more money FUSETRON fuses are on average 2% more energy efficient than the next leadingbrand ** Dual-element feature provides the best time-delay performance Allows for closer sizing to load and better equipment protection Ideal for protection of motors and transformers Class RK5 fuses with 200 ka interrupting rating Limitron 0x better current limitation than basic circuit breakers or fuses ** Advanced protection for sensitive devices and critical components Provides short circuit protection that is on average 0x faster than basic circuit breakers or fuses ** Fast-acting fuses help prevent equipment damage caused by short-circuit events Ideal for critical components in industrial or commercial applications Class CC, J, L, R and T fuses with 200 ka interrupting rating General purpose Basic circuit protection Basic overcurrent protection Meets basic NEC, CEC, UL and CSA requirements for service, feeder and branch circuit protection Class H/K and G fuses with up to 00 ka interrupting rating * 50% higher IR (00kA) than any other UL and CSA Listed Fuse. Includes Class J, L and R fuses. ** Does not include current limiting circuit breakers or current limiting fuses. Protection determined by comparing published values for let through for Class CC, J, R, and T fuses versus a symmetrical RMS waveform at 200kA. *** Test results are based on weighted sales volume of FUSETRON and Ferraz Shawmut (Mersen) fuses by selected amp and volt rating combination. Next leading brand refers to Ferraz Shawmut based on third-party fuse market share data for a twenty-seven month period (July 2008 through September 200). 5

Simplify fuse selection by application 4 2 7 7 0 8 6 5 5 7 4 5 8 2 9 5 6 9 2 4 5 6 7 8 9 0 2 4 5 6 7 8 9 6 Industrial and commercial applications Service, feeder and branch circuit protection Interior lighting Distribution panels Disconnect switches Motor/motor control center Capacitors Transformers Outdoor lighting Emergency lighting Electric heat Welding circuits Plant lighting HVAC chillers/blowers Forklift battery charging station Emergency generator Conveyor system UPS backup power supplies Switchboards Elevator control centers

Easy fuse selection by family Ultimate protection CLASS RK LPN-RK-SP CLASS J LPN-RK LPS-RK-SP LPS-RK LPJ CLASS L LPJ CLASS CC KRP-C LP-CC Advanced protection CLASS RK5 FRN-R FRN-R FRS-R FRS-R Advanced protection CLASS RK KTN-R CLASS J KTN-R KTS-R KTS-R JKS CLASS L JKS KTU KLU CLASS T JJN CLASS CC JJN JJS JJS FNQ-R KTK-R Basic protection CLASS H/K NON CLASS G NON NOS NOS SC SC 7

Speed up fuse replacement Color-coded by family Each fuse label has a unique identifying color representing the family it belongs to. When it s time to replace a fuse, Bussmann series products makes it easier to search for the replacement. When a yellow fuse needs replacing, now you can narrow your search by looking for only the yellow fuses in your crib. LPN-RK LPS-RK KRP-C LP-CC LPJ FRN-R FRS-R FNQ-R KTK-R KTN-R KTS-R JJN JJS KLU KTU JKS NON NOS SC Key performance features and fuse class Family name Key benefit Company address Part number Consistent look for each label Every fuse label now has a consistent look. Critical fuse information is presented in an easy-to-read format across the entire Bussmann UL low voltage portfolio to help speed replacement. Agency listing marks AC voltage rating DC voltage rating UPC scan information Date code Easy to find part numbers To ensure you can easily find the part number when you need to replace fuses, the new label design has the part number located in multiple places of large body size blade fuses. With this updated look, you can easily find the important information regardless of the angle in which the fuse is installed. Part number Part number 8

Enhance safety and relilability while reducing fuse inventory Low-Peak Upgrade program Eaton s Bussmann series Low-Peak Upgrade program leverages our ultimate protection fuses to deliver enhanced safety, improved system reliability and a simplified inventory. With just three simple steps, it s easier than ever to improve your circuit protection while reducing your fuse inventory and cost. What s more, you ll save time and increase productivity - all by using Low-Peak fuses. Let our team of experts walk you through the audit, analysis and implementation of a Low-Peak Upgrade and start realizing savings today. Enhance safety Superior current-limitation helps reduce arc flash hazards. Interrupting ratings up to 00kA for high fault currents. Helps achieve code compliance with OSHA, NFPA and IEEE. Improve system reliability Type 2 no damage motor starter protection reduces downtime. Optional fuse indication to speed troubleshooting. Easily meet selective coordination requirements with 2: amp ratio with any fuse in the Bussmann series Low-Peak family. Simplify inventory One Bussmann series Low-Peak fuse can replace multiple fuses in a variety of applications. In just three simple steps, our team of experts will guide you through the Low-Peak Upgrade program: Audit Analyze Throughout the Bussmann series Low-Peak Upgrade process, you ll have a dedicated team that includes a Bussmann series product authorized distributor and sales representative. Together, they will walk you through the three steps of the program, making it as easy and effortless for you as possible. Implement To get started, visit www.cooperbussmann.com/ lowpeakupgrade 9

Complementary products The broad portfolio of Bussmann series products include more than just UL low voltage fuses. Visit Eaton.com/bussmannseries to learn more. Fuse blocks, holders and PDBs Modular knifeblade fuse blocks Power distribution blocks Compact modular fuse holders Disconnect switches and safety switches Fused rotary disconnect switches Quik-Spec safety switches Compact Circuit Protector Additional fuse portfolio High speed fuses Medium voltage fuses CUBEFuses Surge protection Data signal surge Type SurgePOD surge protective devices DIN-Rail surge protective devices 0

Customer care Customer satisfaction team Available to answer questions regarding Bussmann series products and services Monday-Friday, 7:00 a.m. 6:00 p.m. Central Time. Toll-free phone: 855-287-7626 (855-BUSSMANN) Toll-free fax: 800-544-2570 E-mail: Busscustsat@eaton.com Emergency and after-hours orders Next flight out or will call shipment for time-critical needs. Customers pay only standard product price, rush freight charges, and modest emergency service fee. Place these orders through the customer satisfaction team during regular business hours. After-hours phone 4-995-42 Application engineering team FUSETech, our team of application engineers is available to provide quality answers to your technical questions or concerns. When you need assistance with Bussmann series products or solutions, give us a call or send us an email. We are available Monday-Friday, 7:00 a.m. 5:00 p.m. Central Time. Toll-free phone: 855-287-7626 (855-BUSSMANN) E-mail: Fusetech@eaton.com My.Eaton.com Provides real time product availability, net pricing, order status and shipment tracking. Log onto My.Eaton.com or call: -800-468-705 option # for log-in assistance Online resources Visit Eaton.com/bussmannseries for the latest in new product introductions and more: Product catalogs and profiles Product data sheets Application and technical references Bussmann toolbox Visit Toolbox.bussmann.com to access resources like: Arcing current calculator RoHS compliance product search Available Fault Current Calculator (FC 2 ) SCCR Protection Suite OSCAR 2. compliance software Selective Coordination Designer v.0

Eaton 000 Eaton Boulevard Cleveland, OH 4422 United States Eaton.com Bussmann Division 4 Old State Road Ellisville, MO 602 United States Eaton.com/bussmannseries 207 Eaton All Rights Reserved Printed in USA Publication No. 0092 March 207 Eaton, Bussmann, CUBEFuse, Fuses Made Simple, Fusetron, Limitron, Low-Peak, QuikShip and Quik-Spec are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. CSA is a registered trademark of the Canadian Standards Group. NEC is a registered trademark of the National Fire Protection Association, Inc. UL is a registered trademark of the Underwriters Laboratories, Inc. For Eaton s Bussmann series product information, call -855-287-7626 or visit: Eaton.com/bussmannseries Follow us on social media to get the latest product and support information.