POINT CIRCLE-H LIGHTS PTPS LED TOUCHDOWN & POSITIONING SYSTEM LIGHTED TD/PM CIRCLE & H MARKINGS

Similar documents
POINT ROLLOVER LIGHTS PRL LED v4 HELIPORT INSET LIGHT

POINT OBSTRUCTION LIGHTS SOL LED SOLAR POWERED OBSTRUCTION SYSTEM

POINT WIND CONE PWC FAA L-806 & L-807

POINT WIND CONE PWC FAA L-806 & L-807

ILED Aquarius CIRCLE-H Helideck Lighting System

INSTRUCTION SHEET PRL-97X04 AC AND DC VOLTAGES

SafeSite LED Based Signaling for Hazardous Locations

SafeSite LED Based Signaling for Hazardous Locations

MAR SERIES Fluorescent Lighting for Hazardous Locations

POINT HELIPORT LIGHTS

24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

AFL FLOODLIGHT SERIES

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

Pauluhn ZPL explosionproof LED luminaires For drilling and marine applications

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations

ILED Dorado. User Manual

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

IECEx Certificate of Conformity

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES

Marine Fire and Gas Dampers

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES

TNA-AS-50 OMNI-DIRECTIONAL BATTERY POWERED PORTABLE AIRFIELD LIGHT (PAL) AND TACTICAL MARKER

Spec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

PLED LED CONVERSION KITS

Myers Hubs. Standard Finishes: Aluminum: Natural Zinc: Natural Stainless: Natural

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

CYCLOPS Y Purge Indicator

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Ritorno Square Asymmetrical LED

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

Electric Lift - Universal Drum Rotator STE01-DRU01

PROTECTA III. Construction Tough glass reinforced polyester body

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Terminal Boxes Series 8125

FL Series Light Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2 and 22

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Solenoid coil for control in potentially explosive areas Type BZ

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Hazardous Area LED Lighting Champ FMV LED Luminaires. Champ FMV. LED floodlights for harsh and hazardous areas

LED lighting for drilling & marine Pauluhn ZPL LED luminaires. Pauluhn ZPL. LED luminaires for drilling & marine applications

TS-350 Fully-Flush Under Vehicle Inspection Light Packages

Airfield Lighting. Omnidirectional Medium-Intensity Elevated Light (IDM 2927) Product Description

WL-100 High Intensity Aviation Obstruction Light

ALUMINUM OUTLET BODIES

Operation Manual. TX40 and CX40

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

YFC. Limit switch. Ex d. 24 operating head types

Panelboards & Motor Starters

PY, SPY; FSQC, FP; EPC; AP

COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications

Flameproof Alternators

CPC DX (CPC Dual Transfer Skid) Redundant current to pressure converter assembly

Assembly. Trunk IN + - S U, I U, I. Spur 1

Airfield Lighting Product Description Unidirectional High-Intensity Elevated Light (IDM 6301) Elevated Runway Guard Light Road Holding Position Light

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS

LED CONVERSION KITS. Optical Systems KCK124 PARAGON LIGHTING THE WAY

Plug and Socket Devices SolConeX 16 A Series 8570

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

BETA SWITCHES FOR HAZARDOUS AREA

LED CONVERSION KITS. Optical Systems KCK118 WASHINGTON LIGHTING THE WAY

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

K199 CALIFORNIA - LED ACORN PRODUCT SPECIFICATIONS 39 1/8"

Hazardous Duty Applications

Applications. Illustrated Features

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

CONVECT RADIATE CONDUCT

Mobile Control Units 2930, 2940, 2950 Handheld Enclosures Product Drawings Last Updated 6/20/2008

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

FTS/FTC TAXIWAY LIGHTING. Taxiway Centerline, Stop Bar and Intersection Inset Light MEDIUM-INTENSITY. Compliance with Standards.

Terminal Boxes Series 8125

304 Series LED Recessed Canopy Luminaires

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

SAFR LED S A F R L E D. LED Area Lighting for Hazardous Locations

HAZARDOUS LOCATION CLASSIFIED AREAS LW1 AND LW2 SERIES DOWN OR UP OPTICS

FATO & TLOF dimensions, load bearing (chapter 3) Obstacle Free Sector (chapter 4), Obstacle Limitation Sectors (chapter 4)

PAPI PU3L AIRFIELD LIGHTING. Precision Approach Path Indicator. PAPI or APAPI. Visual Precision Approach Path Indicator Systems. Location on the Field

GTV Series High Pressure Control Valves

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

TS-300 Under Vehicle Inspection Light Packages

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Valve Position Monitors

DuroSite LED Area Light V AC, 24-48V DC, V AC Battery Backup

Oily Water Separators. globally focused on cleaner solutions

ZA292 Under Vehicle Inspection Light Packages

ILED Aquarius Illuminated Windsock. User Manual

Hazardous Location Enclosures INDEX. Hazardous Location Enclosures HAZ-2

Know-how makes the difference. Limit Switches

Oily Water Separators. globally focused on cleaner solutions

Transcription:

Compliances: Listed 1180 II 2 G Ex e mb IIC T6 Gb Tamb -45 to +55 deg C, IP66 & IP67 Listed ATEX Directive 94/9/EC Annex VI & RoHS Directive: 2011/65/EU ATEX Certificate Numbers: TRAC14ATEX0064X & TRAC15ATEX0052X IECEx Certificate Numbers: IECEx TRC 14.0026X & IECEx TRC 15.0016X ETL Listed Class I, Division 2, Groups A B C D, T6 at -55 deg C to +55 deg C ETL Listed Class I, Zone 2, IIC, T6 at -55 deg C to +55 deg C ETL Listed to UL 844 & UL 1598 ETL Listed to UL 1598A Marine Vessels ETL Listed to CSA C22.2 No. 137-M1981 Canada UK CAA CAP 437, Edition 8, December 2016 Registered ISO 9001:2008 American Bureau of Shipping (ABS) Type Approved Product ABS Green Passport per MEPC179 (59) The PTPS Touchdown & Positioning System is designed to fully comply with the UK CAA CAP 437 Standards for Offshore Helicopter Landing Areas, Edition 8, December 2016 for the Lit Touchdown/Positioning Marking Circle and Lit Heliport Identification Marking to insure visibility of the TD/PM Circle & 'H' during night and reduced visibility. Includes ICAO Standards and Recommended Practices relating to offshore helidecks. This system may be installed by any electro-mechanical contractor prequalified by Point Lighting Corporation. Type Classification Mounting PTPS (blank)* Safe Area (all) SCA Surface Cable - Adhesive AX* IECEx & ATEX zones 1&2 - safe area control TDA Thru-Deck Cable - Adhesive EX* Class I, Division 2 - safe area control unit SC Surface Cable - Mechanical AX2 IECEx & ATEX zones 1&2 (all) EX2 Class I, Division 2 (all) Note: See page 2 for mounting system descriptions. * Includes fiberglass safe area control unit enclosure All external hardware is grade 316 (A4) Note: Each constant current PTPS strip uses 0.75 watt or less. stainless steel. Power consumption is less than 100 watts for a typical system; see page 5. Metal housings are copper-free (< 0.4%) Note: Control Unit input voltage may be 120V AC, 220-240V AC or 24V DC heat treated aluminum. Also see page 5. PTPS Class I, Division 2 system installed and operational on a rig in Singapore. HL-5.0.0 September, 2017

MOUNTING SYSTEMS Most metal helidecks are not as flat as required for the installation of a highly technical 25mm thick lighting system. Proper mechanical integrity that assures CAP 437 photometrics requires a table-top flat surface. SCA SURFACE CABLE ADHESIVE This is the standard mounting system offered for most applications because it creates a perfectly flat surface for the system segments. Interlocking 316L stainless steel plates are predrilled and tapped for mounting the PTPS circle segments and H subsections as well as all the surface cable protective covers. All the required 316L stainless steel hardware is included right down to the washers that protect the segment finish. All system lighting segments use our exclusive Marine Treatment process described on page 6. This coating process and a very thin neoprene gasket isolates the copper-free aluminum of the segment from the 4.76mm thick stainless steel plate. The adhesive (by others) isolates the plate from the metal deck surface. The stainless steel mounting plates on the yellow circle are finished in yellow. The mounting plates also replace the deck s painted H and are all finished in white. The installer does not have to paint the H. We recommend specific adhesives in the instructions and our recommended installer is well trained in suitable adhesives. Typical PTPS-SCA arrangement on interlocking 316L stainless steel mounting plates to form the H. SC SURFACE CABLE MECHANICAL This is an optional mounting system intended for a table-top flat landing surface such as a land-based concrete pad or a new perfectly flat metal deck surface. There are no mounting plates so there are about 1,000 mounting points to be installed in the landing surface. The hardware choice and supply is by others (not included). This is a much more labor intensive installation than SCA. Note: All PTPS installations must be performed as one efficiently planned process under dry conditions for system integrity. CATALOG NUMBERING All PTPS catalog numbers end in a 7-character serial number that defines the system size, voltage and special features. Example: PTPS-AX-SCA-A901335 TDA THRU-DECK CABLE - ADHESIVE This optional mounting system is a variation of SCA as the same interlocking and predrilled 316L stainless steel plates are used, but the junction boxes are designed for the cables to exit through holes in the deck surface. This may be some of the cables or only at certain points so it is customized to the specific situation. Some decks cannot have any penetration of the surface in which case the SCA system should be used. LOCATION OF CONTROL UNIT The standard SCA mounting system includes enough cable and protective covers to exit the edge of the deck surface as well as some additional cable. The PTPS control unit has one simple 3-position switch on the door ON-OFF-REMOTE where the REMOTE position allows for a simple switch at another location such as a control panel. Therefore, the PTPS control unit can be mounted anywhere inside or outside within 200-ft of the helideck yet still be controlled from a more distant location. In accordance with CAP 437, there is a one-time brightness adjustment in the control unit. CAP 437 does not allow for manual brightness control by an operator.

ANTI-CORROSIVE FINISH The exclusive POINT LIGHTING CORPORATION Marine Treatment (MT) finish is used for all marine, high salt content air and other corrosive environments. The H strips are MT white finish and the TD/PM Circle strips are yellow finish. See page 5 for treatment process. MOUNTING HARDWARE POINT LIGHTING supplies all mounting hardware for the standard SCA system only. All mounting thru-holes in the segments, junction boxes and cable covers are 7mm diameter for ¼-inch or M6 hardware. DETAIL THE H INTERCONNECTED PTPS SUBSECTIONS WITH JUNCTION BOXES Typical PTPS six-element section with LED board and glass lens Typical PTPS Junction Boxes DETAIL INTERCONNECTED H PTPS SIX-ELEMENT SUBSECTIONS WITH WHITE FINISH EMIT GREEN LIGHT Strong machined aluminum housing and soda lime crystal tempered glass lenses. POINT LIGHTING CORPORATION has decades of experience producing load-bearing aviation lighting products. No plastics to crack, fade and crumble from sunlight. CERTIFIED WATERPROOF TO IP67 * THE TD/PM CIRCLE PTPS SEGMENT WITH JUNCTION BOX OPERATING UNDERWATER. * When properly installed. Certified to IP66 & IP67.

The H is painted white and also marked with PTPS subsections with white finish and emitting green light. The PTPS subsections securely interlock for a mechanically and electrically sealed installation. TYPICAL H LAYOUT The TD/PM circle is painted yellow and also marked with PTPS sixelement segments with yellow finish and emitting yellow light.

PTPS PHOTOMETRIC COMPLIANCE Testing performed by Hoffman Engineering goniometer serial number AGS-1130-004 and Spectrometer SMS-700 serial number HEC-6542. Calibration Date: 19 September 2014 Test Date: 18 November 2014 PTPS YELLOW CIRCLE SEGMENT CAP 437 PHOTOMETRIC COMPLIANCE CHART PTPS GREEN H SUBSECTION CAP 437 PHOTOMETRIC COMPLIANCE CHART Note: The colored lines define the limits set in CAP 437. The brown line is the graph of the measured points.

TESTED CERTIFICATIONS AVAILABLE ABS Type Approval UL 1598A Marine Vessels Class I, Division 2 (Zone 2) EN 60079-0 & MIL-C-7989B FAA & CAP 437 IEC 60598-1 UL 746C (f1) CAP 437 ABS Classed Vessels, MODU or Facility Installation on Marine Vessels UL & CSA for Use in Hazardous Areas Glass Impact Load-bearing Ingress Protection IP66 & IP67 Ultraviolet Light Chromaticity & Photometry (Optics) POWER CONSUMPTION Total power consumption for a typical system for a D-value of 22-meters: CAP 437 standard intensity setting: 62 watts 99 VA CAP 437 increased intensity setting: 95 watts 154 VA CORROSION PROTECTION MARINE TREATMENT SPECIFICATION The Point Lighting Corporation PTPS corrosion protection process goes far beyond simple powder coat painting. For example, the chrome-free conversion coating is the only treatment used by Rolls Royce for aircraft engine turbine blades. Application: Circle & H Segments and Junction Boxes The treatment process shall be: Clean with Mild Acid Cleaner Glass Bead Blast Apply Chrome-Free Aluminum Conversion Coating Oven Dry Apply Epoxy Powder Coat with zinc free primer Oven Dry Apply Polyester Powder Coat Finish Coat Oven Dry Apply Clear Anti-Skid Textured Coating to applicable surfaces GENERAL GUIDELINE FOR NUMBER OF TD/PM CIRCLE SEGMENTS The TD/PM circle lighting is centered on the 1-meter wide painted circle. Therefore, lighting is positioned on a circle defined by the mean diameter of the TD/PM yellow painted circle. The diameter of the TD/PM circle should be as defined in CAP 437 based on the maximum D-value of the helideck landing surface. This guideline is for estimating purposes only and the purchaser is responsible to specify the actual mean diameter of the painted TD/PM circle. D-Value: 18.1 to 20 meters Segments: 24 20.1 to 22 26 22.1 to 24 28 24.1 to 26 30 26.1 to 28 32

CROSSBAR DETAIL OF THE LIGHTED H The detail at right shows that only four surface junction boxes have cables that penetrate the deck through 1-inch holes. These cables link to junction box (by others) below the deck. CONTROL UNIT ENCLOSURES Safe Area: NEMA 4X AX: ATEX zones 1 & 2 EX: Class I, Division 2 (Zone 2) P O I N T L I G H T I N G C O R P O R A T I O N Mail: P.O. Box 686, Simsbury, CT 06070 Plant: 61-65 West Dudley Town Rd, Bloomfield, CT Tel 01 860.243.0600 USA Fax 01 860.243.0665 email: Info@PointLighting.com website: www.pointlighting.com