On Demand, Differential Pressure Controls

Similar documents
MPS AND MPS PR¼ 16 OUTPUT DEMAND CONTROLLER PENTAIR CLEAN AIR SYSTEMS. AVS Danmark ApS Skelvej Hedehusene

ECONOMISER SERIES E2T USER MANUAL

AUTO-EC-3-E-PLC Electric Filter Backwash Controller Operation & Maintenance Manual

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER

REVISION HISTORY REVISION HISTORY

lubrication systems CME Electric pump for oil and soft grease volumetric

Construction. Function. Application area. Jet filter Shock-p ressure tig ht. Model DE / 2 / 1

Laboratory Room Controller

three different ways, so it is important to be aware of how flow is to be specified

TWO-WAY LED MANUAL / AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide WARNING

Documentation. RM-BV4 Micro DP. Filter control

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Redundant Control System

600/700 SERIES FLANGED VALVES PENTAIR CLEAN AIR SYSTEMS

Auto Mains Failure AMF Controller AE10113

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.

ILC PICO-MAX ELECTRIC GREASE PUMP Automatically Lubricates Small, Medium and Large Machinery

TRESHOLD SENSORS LOGIC PNEUMATIC COUNTERS TIMERS VALVES

TWO-WAY LED AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide WARNING

4 Redundant Control System

Intelligent Sprinkler Control System

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

ProMinent S i g m a / 3 Motor Diaphragm Metering Pumps

Total Control Board. Installation, Operation and Maintenance Manual. Publication 2949A (GB) (From October 2007)

400 SERIES MANIFOLD MOUNT VALVES PENTAIR CLEAN AIR SYSTEMS

3 Spin Klin Battery Operation and Maintenance Manual

INSTRUMENTATION & CONTROL

Controller Specification Sheet

TROUBLESHOOTING TP. Index

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Application Engineering

Owner s Guide CA2LED5

GM PTO. Systems; Part 2 of 2

INSTALLATION GUIDE. FCC ID NOTICE

MECAIR 600/700 SERIES FLANGED VALVES CLEAN AIR SOLUTIONS PRODUCT LEAFLET

200 SERIES THREADED VALVES PENTAIR CLEAN AIR SYSTEMS

Spin Klin 12" Super Flow

AUTOMATIC AND MANUAL TRANSMISSION MODELS* *MUST USE M SERIES REMOTE STARTER!

: Automation Laboratory 1

Powers TM Controls SW 134 Pressure Electric Switch (Adjustable Differential)

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL

DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE) INSTALLATION AND OPERATING INSTRUCTIONS

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP

TWO-WAY LCD AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

Owner s Guide CA2LCD5

Machine Specification

Document ID# Chevrolet/Geo Corvette

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

AIR COOLED RECTIFIER SPECIFICATION S-50-A



-M- Flow rate 100 l/min. M5 Compact System Key features

Visit for more technical information & downloads

TWO-WAY LED MANUAL TRANSMISSION REMOTE STARTER. User Guide WARNING

User Guide TWO-WAY LED AUTOMATIC/MANUAL TRANSMISSION REMOTE STARTER WITH FULL ALARM SYSTEM

SERVO-TOP II ELECTRONIC ACTUATOR

MECAIR 400 SERIES MANIFOLD MOUNT VALVES CLEAN AIR SOLUTIONS PRODUCT LEAFLET

THE TOTAL SOLUTION PROVIDER

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

300 SERIES DRESSER NUT VALVES PENTAIR CLEAN AIR SYSTEMS

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

DKG-114 MANUAL AND REMOTE START UNIT

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

Application Engineering

5. OVERCURRENT RELEASE (OCR)

Updated: October 2012

Atlas Automotive. Equipment. Electro-Mechanical. Design Features

ProMinent Sigma/ 1 Motor Diaphragm Metering Pumps

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

BoosterpaQ Hydro MPC-ED Guide Specification

OK-01 TRAM WHEEL FLANGE LUBRICATION APPLICATION DESCRIPTION

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Operator s Series 300 Generator Paralleling System

PLC Controlled High Performance Automatic Grease Lubricator

OPERATING INSTRUCTIONS

MECAIR 200 SERIES THREADED VALVES CLEAN AIR SOLUTIONS PRODUCT LEAFLET

UD SERIES COMPRESSORS

Pneumatic control systems

THE HEART FOR YOUR PLANTS

HERZ Motorised Actuator

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps

SiCan Simple CAN Extension Charger to PacMon

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

The Mikrofill Electronic Filling Device. (EFD)

DGC-2020 DIGITAL GENSET CONTROLLER

AS-1774 / 1774U. User Guide 5-BUTTON AUTOMATIC / MANUAL TRANSMISSION REMOTE STARTER

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

SmartPak Welding Controller WK-MPS-16 Constant Current

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

M9210-xxx-3 Electric Spring Return Actuators

CONTROL PTY LTD Phone: (02) UNIT 14/62 OWEN ST Fax: (02) GLENDENNING NSW 2761 INCA MODEL PV2

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Application Examples Nano ICCS with Toggle Function

Components Power Supplies and Converter DC/AC Converter Generic Product Catalog

DESCRIPTION AND OPERATION ICE DETECTION SYSTEM

GS Series. with new controller SM30

Transcription:

On Demand, Differential Pressure Controls 20 Series Pulse Controller The Goyen 20 Series Pulse Controller is an advanced microprocessor controller of the cleaning system in reverse pulse filters in pneumatic systems. The 20 Series Pulse Controller can operate in the following modes: Off Manual Automatic In AUTOMATIC mode, sequential cleaning is initiated only when the differential pressure (DP) across the filter reaches a predetermined level. Once the DP is reduced to an acceptable level, sequential cleaning ceases. Features of the 20 Series Pulse Controller include: Adjustable pulse on time to 1m sec. Range 10 to 999ms. Adjustable pause time to 1sec. Range 1 to 999 sec. Microprocessor control eliminates drift. Pause in after cleaning option adjustable to 1sec. Range 1 to 999sec. Fast set up. Number of after cleaning cycles adjustable from 0-99. Automatic shutdown from integral Delta P switch (no wiring).

Alarm options. Fast set up Valve diagnostic display. Low air pressure option Self-diagnostic function 200 Series Pulse Controller The Goyen 200 Series Pulse Controller is an advanced microprocessor controller of the cleaning system in reverse pulse filters in pneumatic systems. The 200 Series Pulse Controller can operate in the following modes: Off Manual Automatic In AUTOMATIC mode, sequential cleaning is initiated only when the differential pressure (DP) across the filter reaches a predetermined level. Once the DP is reduced to an acceptable level, sequential cleaning ceases. Features of the 20 Series Pulse Controller include: Adjustable pulse on time to 1m sec. Range 10 to 999ms. Adjustable pause time to 1sec. Range 1 to 999 sec. Microprocessor control eliminates drift. Pause in after cleaning option adjustable to 1sec. Range 1 to 99sec. Fast set up. Number of after cleaning cycles adjustable from 0-99.

Automatic shutdown from integral Delta P switch (no wiring). Alarm options. Fast set up Valve diagnostic display. Low air pressure option. Self-diagnostic function. Valve firing display. Display of current differential pressure. GC3000 Series Cleaning System Controller (USA ONLY) The Goyen Go-Co GC3000 series cleaning system controller was designed to satisfy the requirement for reliable 'demand' cleaning. The unit has two major components: A differential pressure gauge with adjustable high and low set points, and Integral solid state relay electronics, a programmable, microprocessor based timer card. Three modes of operation can be programmed; 'off', 'continuous' or 'demand'. Off is primarily used to isolate the system during maintenance. Continuous mode sequentially switches valves on and off. Demand mode is when the cleaning cycle is initiated by the pressure drop across the filter. In practice demand cleaning reduces the number of cleaning pulses in a given period of time resulting in extended bag life, reduced compressed air consumption, longer valve life, lower emissions and less service downtime.

Economist Model MCS Economist Model - MCS The economist model "MCS" uses advanced microprocessor technology, expressely designed to control the interval and the pulse time of diaphragm valves using the DP and focusing on reverse pulse-jet systems with pneumatic cleaning procedures. All the technical characteristics satisfy the "CE" Directives which relate to isolation and low voltage power. The unit has been tested by an authorised institute and is in conformity with the European Regulation 89/336 EEC and 93/68 EEC. The MCS is available with a minimum of 4 outlets (MCS4) up to a maximum of 128 outlets (MCS128). The intermediate models increment in multiples of 4 (MCS4, MCS8, MCS12, etc.). The principle of the MCS is as follows: an internal sensor registers the progress of the DP in the filter and when it exceeds the value of the set DP, the unit automatically sends a signal to the diaphragm valves in sequence (skipping the outlets which are not connected or where there is no charge recognised). The unit also allows you to set the MANUAL CYCLE TIME (this is the time it takes for all the valves to complete an entire cleaning cycle). This way you obtain the automatic regulation of the Pause Time between one valve and the next. All this is possible thanks to a sophisticated algorithm, which is able to automatically optimize the Pause Time, starting from the set Manual Cycle Time. On the digital display of the unit, you are able to identify all the operating values, such as the Set DP, DP Alarm, Pause Time, Hour Counter, No. of cycles for Shut Down Cleaning and the relative Pause Time. The Economist also has the PRECOATING function, which subordinates the start of the cleaning cycle until such time that a preset DP value for PRECOATING has been reached (this DP value has to be greater than the Set DP). This allows the filtering elements to overload with reagents and preparation powders. It is possible to set an independant

value for the DP ALARM as well. Main Features Timed sequential control of the electronic valves with zero-crossing to eliminate electrical interference. Short-circuit alarm, microprocessor malfunction alarm and alarm of exceeded DP. Regulation of the set DP, pulse time, no. of cycles in final cleaning, with indication on the display. Setting of the MANUAL CYCLE TIME (this is the time it takes for all the valves to complete an entire cleaning cycle). PRECOATING function (start of the cleaning sequence subordinated to the achievement of the DP PRECOATING), for filters that have to be overloaded with reagents and preparation powders. Easy predisposition outlets voltage (AC/DC) and inlet voltage (AC). Automatic system for the command of one or more cycles for the final cleaning. Hour counter (indicates the number of hours which the filter has actually worked. From 0 to 9999 hours).