4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating,

Similar documents
3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm

Pilot operated 2 port solenoid valve (general purpose valve) AP11/AP12 Series. Air, water, kerosene, oil (50 mm 2 /s or less) -10 to to 60 B

General purpose direct acting 2, 3 port solenoid valve

Coolant Valve. Air Operated/External Pilot Solenoid

Discrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Exclusively for air pressure system and air-hydro circuit control

Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8

High Pressure Coolant Valve

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3GA1/2/3, 4GA1/2/3 Series Applicable cylinder bore size: ø20 to ø100

Series VP3145/3165/3185

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Discrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

Series DV

NO (normally closed) type Common supply type (port C pressurization) MPa MPa MPa C C

HMV/HSV. Manual switching valve. 4 port valve

Discrete direct acting 3 port solenoid valve (general purpose valve) NC pressurization type. Port size: Rc1/8, Rc1/4, Rc3/8

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

Air Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. Port size: 1/4 to 1 JIS symbol Specifications Description

HVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Series VP3145/3165/3185

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series SV1000/2000/3000/4000

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

4/5 Port Solenoid Valve

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

PD3/PDV3-20A/25A/40A Series

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Air Operated Valve

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Coolant Valve. VNC Series. Cylinder actuation by pilot air

CMF2 Series Applicable cylinder bore size: Max. ø160

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Pilot operated 2 port valve for dust collector control (pulsejet valve) Common specifications Air operated type. Solenoid valve mounted type Item OUT

Symbol. Single DS 2120 R2 P R1. How To Order. Body Type 2 : Body Ported Type. Body Option O : Standard

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

HN B G1/US B G2/US B G3

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

0.35 W (Without light)

3 Port Solenoid Valve Direct Operated Poppet Type

4/5 Port Solenoid Valve

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Pilot kick type 2 port solenoid valve for dry air (general purpose valve) ADK11-Z Series. NC (normally closed) type

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Transmitters: Relay Valve

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

Rubber Seal 5 Port Pilot Type/Body Ported Type. Symbol. How to Order

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve

3 Port 3 Position Valve

AB41E4-Z Series. Pressure and explosion proof structure d2g4 (flame-proof grade 2, ignitability G4) NC (normally closed) type. Port size: Rc1/4, Rc3/8

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

Pneumatic Valve 4V100 Series

3 Port Solenoid Valve

Individual wiring manifold Sub base porting Direct mount type/din rail mount type M4GB1 2 3/M4GB1 2 3-D Series

Pilot Operated 2 Port Solenoid Valve for Dry Air

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

Series SY3000/5000/7000

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

VXP21/22/23 Series. Pilot Operated 2 Port Solenoid Valve. For Air, Gas, Steam, Water and Oil VX2 VXK VXD VXZ VXS VXB VXE VXP VXR VXH VXF VX3 VXA

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

Series VQZ1000/2000/3000 Single Unit

Series SY3000/5000/7000

Series VQ Port Solenoid Valve

Solenoid pilot operated spring return inline valves with nonlocking overrides, 120V, 60 Hz, and cablegrip connector

New Products COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER. Lightweight and large flow rate, low power consumption Improved corrosion resistance!

Process Valve/Series VN

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

Steam Valve. Series VND. 2 Port Valve for Steam. With indicator (Option) By adopting of PTFE seal, the valve is suited for steam.

VNA VNB SGC SGH VNC VNH VND VCC

5 Port Solenoid Valve

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

3 Port Solenoid Valve

Series DV

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Plug-in manifold W4G4 Series

Mounting style. Custom stroke length (per mm) Max. stroke length (mm) Axial foot type. Basic type

Transcription:

MNE0 M MN W L/ QV JIS symbol 5 port valve position single solenoid position double solenoid position all ports closed position //R connection position P// connection Common specifications Descriptions Valve and operation type Pilot operated spool valve Working fluid Compressed air Max. working pressure MPa 1.0 Min. working pressure MPa Refer to the individual specifications below. Withstanding pressure MPa 1.5 mbient temperature C to 0 (no freezing) Fluid temperature C 5 to 0 Lubrication Not required (when lubricating, Protective structure Vibration/impact m/s Working environment use turbine oil ISO VG.) Dust proof 50 or less / 0 or less Containing corrosive gas is impermissible. Note 1: mbient temperature refers to the temperature for storage and installation, and differs from fluid temperature, which applies during operation. Descriptions Min. working pressure MPa Port size Note position Double solenoid ll ports closed position //R connection P// connection Response time Note ms Weight Discrete valve / body porting 5 port pilot operated pneumatic valve 0/1// Series Individual specifications position kg Double solenoid position pplicable cylinder bore size: ø1 to ø0 mm ()0 Note 1 0. Rp M5 1/8 0.1 0.18 Refer to Intro 17 for details. Electric specifications Descriptions ()0 to 1 / Rated voltage V C DC 0, 00 (50 / 0Hz) 1, Rated voltage fluctuation range ±% 0 V Starting C 00 V current 1 V DC V 0 V Holding C 00 V current 1 V DC V 0 V Power C 00 V consumption 1 V W DC V Heat proof class 0.05 / 0.0 0.170 / 0. 0.0 / 0.0 0.00 / 0.070 0.0 0.500 0.075 0.50 0.08 / 0.0 0.0 / 0.080 0.017 / 0.01 0.050 / 0.00 0.0 0.500 0.075 0.50 1.8 / 1. 5.0 /.0.1 / 1. 5.0 /.0 1.8 1.8 (molded coil) Note1: The 0 VC 50/0 Hz rated voltage can be used at 1 VC 0 Hz, and 00 VC 50/0 Hz can be used at 0 VC 0 Hz. 1 0. 0. 0.0 Rp Rp 1/8 1/ 0.18 0. 0. 0. 0. Rp 1/ 50 0.5 0.8 1. Rp 1/ 0. 0. 50 0. 0. 1.0 Note 1: () is 0 for the single type. Note : G and NPT threads are usable for the () 0, 1,, and piping port threads. Contact CKD for details. Note : Response time is the value when supply pressure 0.5 MPa, not lubricated and ON. The value varies depending on pressure and quality of lubricant. Rp /8 80

0 to Series Flow characteristics Model no. () 0 Note position 1 position position position position position position position position Solenoid position Double solenoid Double solenoid Double solenoid ll ports closed //R connection Double solenoid ll ports closed //R connection Double solenoid ll ports closed //R connection P// connection Double solenoid ll ports closed //R connection P// connection Port size M5 Rp1/8 Rp1/8 Rp1/ Rp1/ Rp1/ Rp/8 C (dm / (s bar)) 0.1 0.7.0 1.5 1..0.5..0.5.0 5.8. 5.1. b 0.5 0.7 0. 0.1 0. 0. 0. 0. 0.5 0. 0.5 0. 0. 0. 0. Note 1: Effective sectional area S and sonic conductance C are converted as S 5.0 x C. Note : () is 0 for the single type. MNE0 M MN W L/ Copper and PTFE free Flow path free of copperbased and PTFEbased materials ** Voltage (0 not available) P QV Discrete 5 port pilot operated valve 81

Discrete valve: How to order body porting MNE0 1 0 08 M L C0V M MN W L/ QV 0 to Series Model no. Solenoid position C Port size D E Electric connection Note on model no. selection F Other options Note 1: R1 and R for 0 are M5. Note : R1 and R for 1 are Rp1/8. Note : Rc threads and NPT threads are available for the piping port threads. Contact CKD for information. Note : When selecting the DIN terminal box for the lock type with a manual lever, the terminal box must face outward during use. G Voltage Symbol Descriptions Solenoid position 1 5 C M5 0 08 lank P P1 S H N NC NO position single solenoid position double solenoid position all ports closed position //R connection position P// connection M5 Rp1/8 Rp1/ Rp/8 Refer to the next page for wire connections. C0V C00V DC1V DCV C1V C0V Port size D M1 Locking lank Locking lank Nonlocking M Nonlocking M Locking with manual lever M Nonlocking with dust proof cover M Nonlocking upward R position change E Electric connection F Other options G Voltage Note No option Mounting bracket (L shaped bracket) (position single solenoid) Mounting bracket (U shaped bracket) Surge suppressor (variable resistor) attached Check valve attached (pplicable to only position all ports closed) Plug attached ( port valve) way valve with plug assembly (C1:. E1: R1) way valve with plug assembly (C:. E: R) 0 VC 50/0Hz 00 VC 50/0Hz 1 VDC VDC 1 VC 50/0Hz 0 VC 50/0Hz Note 1 Note Note Model no. F F1 F F 0 <Example of model number> 08MP1C0V Model: Solenoid position : position //R connection C Port size : Rp1/ D : Nonlocking E Electric connection : lank, DIN terminal box (Pg11) F Other options : Mounting bracket G Voltage : 0 VC 8

0 to Series (Electric connection list) E Electric connection Small terminal box No lead wire lank No lead wire L No lead wire with light Note L Lead wire length (0 mm) with light Note DIN terminal box lank L F DIN terminal box (Pg11) DIN terminal box (Pg11) with light Note DIN terminal box (G1/) Cconnector (lead wire lateral) C C00 C01 C0 C0 C1 C C0 C1 C C C Lead wire length (0 mm) Lead wire length (500 mm) Lead wire length (00 mm) Lead wire length (000 mm) Lead wire length (00 mm) No lead wire Lead wire length (0 mm) Lead wire length (500 mm) Lead wire length (00 mm) Lead wire length (000 mm) Lead wire length (00 mm) No lead wire Dconnector (lead wire upward) D D00 D01 D0 D0 D1 D D0 D1 D D D Lead wire length (0 mm) Lead wire length (500 mm) Lead wire length (00 mm) Lead wire length (000 mm) Lead wire length (00 mm) No lead wire Lead wire length (0 mm) Lead wire length (500 mm) Lead wire length (00 mm) Lead wire length (000 mm) Lead wire length (00 mm) No lead wire Grommet lead wire lank E E1 E 1 L G GL Grommet lead wire Grommet lead wire Conduit lead wire (CTC1) Conduit lead wire (G1/) Conduit lead wire round terminal box (G/) Conduit lead wire round terminal box (G1/) Conduit lead wire round terminal box (G1/) with light Note 5 Conduit lead wire round terminal box gland (a) Conduit lead wire round terminal box gland (a) with light Note 5 Note : The L and L DC type have a builtin surge suppressor. (Refer to page 887 for the circuit drawings with light and surge suppressor. ) Note 5: L/GL 1VDC are not available. Model no. F F1 F F 0 MNE0 M MN W L/ QV Discrete 5 port pilot operated valve 8

MNE0 ()0 Series Dimensions 0 position single solenoid: (grommet lead wire) 00 position double solenoid: (grommet lead wire) M MN W L/.5 1.5. (M5) (0) 70 M5 x 0.8 (M5) Rp1/8 (0): C1/C M5 x 0.8 (M5).. M5 x 0.8 Rp1/8 (0): S E1/E.5 88.5 ø.5 7. Lead wire 0/0.18 Length 0 mm Mounting bracket: (P: position single solenoid only) Mounting bracket: (P1) 1 78 1.5 8.5 QV 8 55 5.8 1 1 ø.5 7 57 ø.8 1. 8

()0 Series Dimensions Small terminal box: () position single solenoid position double solenoid MNE0 M G1/ MN W Small terminal box with light: (L/L) 8 7 8 Lead wire 0 mm (L) 5 8 8 Pg7 L/ 1 171 Cconnector: (C, C0*, C1, C, C*, C) Lead wire Length 0 to 000 mm (C, C0*, C, C*).5 17 Dconnector: (D, D0*, D1, D, D*, D) Lead wire Length 0 to 000 mm (D, D0*, D, D*) QV.5 17 position change: (R) 7 5 Discrete 5 port pilot operated valve 87

MNE0 1 Series Dimensions 1 position single solenoid: Small terminal box position double solenoid: Small terminal box M MN W 0 (0) (08) Rp1/8 (0) Rp1/ (08): C1/C L/ 1 1.5 7.5 ø.5 8.5 G1/ 8.5 17 1 11 17.5 Rp1/8 (0) Rp1/ (08): S Rp1/8 E1/E 1 0 position: Small terminal box Mounting bracket: (P: position single solenoid dedicated) QV 7 Mounting bracket: (P1) ø5.5 118.5 1.8 5 55 0 ø.8 70 1. 88

Dimensions Small terminal box with light: (L/L) position single solenoid.5 1 Series position double solenoid, position * The drawing shows position double solenoid. MNE0 M MN Grommet lead wire: (E) 1 8 Pg7 Lead wire 0 mm (Only L) position double solenoid: 17 (position: 177) W Lead wire 0 mm L/.5.5 1 position double solenoid: 1.5 (position: ) Cconnector: (C, C0*, C1, C, C*, C).5 118.5 Lead wire Length 0 to 000 mm (C, C0*, C, C*) position double solenoid: (position: 18) Dconnector: (D, D0*, D1, D, D*, D) Lead wire Length 0 to 000 mm (D, D0*, D, D*).5 QV 118.5 position double solenoid: (position: 18) position change: (R) Discrete 5 port pilot operated valve 1 position double solenoid: 177 (position: 0) 8

MNE0 M MN W L/ Series Dimensions position single solenoid: DIN terminal box ø.5 installation hole 50 0 Rp1/ C1/C 8 1 1 1 Rp1/ E1/S/E 5.5 (0) 18 Rp1/8 PE 5.5 Pg11 0 position double solenoid: DIN terminal box 8.5 0 0 position: DIN terminal box Mounting bracket: (P: position single solenoid dedicated) QV 117 7 80 Mounting bracket: (P1) ø5.5 ø.8 80 70 0 18 15.5 75 8 7 5.8 1. 00 * Refer to page 5 for a check valve.

Series Dimensions DIN terminal box with indicator light: (L) Pg11 position single solenoid position double solenoid, position * The drawing shows position double solenoid. MNE0 M MN 0 Grommet lead wire: (E) 18.5 position double solenoid: (position: 117) position double solenoid: 0 (position: 75.5) W Lead wire 0 mm (0/0.18) L/ 5 0 18.5 position double solenoid: (position: 117) position double solenoid: 0 (position: 75.5) Conduit lead wire: (E1/E) E1: CTC1 E: G1/ Lead wire 0 mm 80 177 position double solenoid: (position: 117) position double solenoid: 58 (position:.5) Round terminal box: (1//L) ø position double solenoid: (position: 117) QV 11 1/: 17 L:.5 position change: (R) 17 1 position double solenoid: 58 (position:.5) position double solenoid: 0 (position:.5) Discrete 5 port pilot operated valve 178 position double solenoid: 0 (position:.5) 01

MNE0 Series Dimensions position single solenoid: DIN terminal box position double solenoid: DIN terminal box M MN Rp1/ (08) Rp/8 (): E1/S/E W L/ ø.5 installation hole 0 55 Rp1/ (08) Rp/8 (): C1/C 5 55.5 7.5 18.5 8 5 position: DIN terminal box (0) Rp1/8: PE.5 5 Pg11 5 5 Mounting bracket: (P: position single solenoid dedicated) QV 0 8.5 18 Mounting bracket: (P1) 5 ø5.5 18 8 ø.5 7 1 80 5 55 5 1. * Refer to page 5 for a check valve. 0

Dimensions DIN terminal box with indicator light: (L) position single solenoid 5 Series position double solenoid, position * The drawing shows position double solenoid. MNE0 M MN Grommet lead wire: (E) Conduit lead wire: (E1/E) Round terminal box: (1//L) 18.5 18.5 E1: CTC1 E: G1/.5 ø Lead wire 0 mm (0 x 0.18) 5 85 5 Lead wire 0 mm 118 1/: 1 L: 15.5 position double solenoid: (position: 18) position double solenoid: 5 (position: 8) position double solenoid: (position: 18) position double solenoid: 5 (position: 8) position double solenoid: (position: 18) position double solenoid: 70 (position: 1) position double solenoid: (position: 18) W L/ QV position change: (R).5 08 position double solenoid: 70 (position: 1) position double solenoid: (position: 8) Discrete 5 port pilot operated valve 1 position double solenoid: 7 (position: 17) 0

0/1 Series MNE0 M MN W L/ Internal structure and parts list 0 00 1 position single solenoid position single solenoid 7 position double solenoid position double solenoid 5 1 11 (C) 5 1 11 7 R1 (E1) 5 P (S) (C) R (E) 1 (C) 8 8 11 1 (C) R1 (E1) P (S) R (E) 7 1 position ll ports closed 5 (C) 1 11 8 1 1 1 QV Main parts list No. Parts name Material 1 5 7 8 11 1 1 1 ody Valving element (spool) Cap Coil assembly (solenoid valve) Seal assembly Piston () assembly Piston () assembly Cylinder Cylinder O ring Pilot valve body Small terminal box ody block Spring retainer luminum alloy diecasting luminum luminum alloy diecasting luminum luminum Nitrile rubber luminum alloy diecasting luminum alloy diecasting Stainless steel //R connection Repair parts list No. / parts name Model no. 0 00 1 1 5 7 5 7 Repair kit Seal assembly Piston () assembly Piston () assembly Coil assembly * 0K 00K 1K K 1K 1 11 R1 (E1) 1 1 P (S) 5 R (E) 1 15 111 Discrete miniature pneumatic valve model no. (asic P51MOE[Voltage]) Discrete miniature pneumatic valve model no. (asic P51MO[Voltage]) *: Consumables are stocked as a kit, and cannot be purchased individually. (The kit consists of the seal assembly and piston () and () assemblies. The coil assembly is not included.) 11 1 8

Internal structure and parts list / position single solenoid 0/ position double solenoid 11 1 1 R1 (E1) 7 8 1 5 P (S) (C) R (E) 7 8 1 5 (C) / Series 1 MNE0 M MN W L/ R1 (E1) P (S) R (E) 1 / position all ports closed 1 1 1 7 1 8 5 (C) 0/ //R connection Main parts list 50 P// connection No. Parts name Material 1 5 7 8 11 1 1 1 1 ody Valving element (spool) Cap Plunger Plunger spring Coil assembly Seal assembly Piston () assembly Piston () assembly Cylinder Cylinder ody block Spring retainer O ring Pilot valve body DIN terminal box luminum alloy diecasting luminum luminum alloy diecasting luminum luminum luminum alloy diecasting Stainless steel Nitrile rubber luminum alloy diecasting Repair parts list No. / parts name Model no. 0 0 50 R1 (E1) P (S) 7 8 7 8 Repair kit Seal assembly Piston () assembly Piston () assembly Coil assembly * K 0K K K K K R (E) 5 1 11 11 *0 [Electric connection] COIL[Voltage] *0 [Electric connection] COIL[Voltage] *: Consumables are stocked as a kit, and cannot be purchased individually. (The kit consists of the seal assembly and piston () and () assemblies. The coil assembly is not included.) *: Plunger assembly is included with a coil assembly. 1 QV Discrete 5 port pilot operated valve 85