PROMAX INSTRUCTION MANUAL

Similar documents
Certo Chemical Dilution System

DEMA DILUTION-AT-HAND EXTREME 800 Series Chemical Dispensers

665 Series Dispenser. Metering tip kit

DEMA 652 DUO-FEED INSTALLATION INSTRUCTIONS

DEMA Pro-Fill I Sink Dispenser

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

DEMA 651AG SINGLE-FEED INSTALLATION INSTRUCTIONS

Tools Needed for Mounting Cleá Filling Station

DEMA Pro-Fill II Sink Dispenser

DEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS

WATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: T, TX, T, BT,

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

DEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS

CHEMTROL TRIPLE SPACE SAVER CLEANING STATION #U16242 INSTALLATION INSTRUCTIONS

BLACK SHADOW SERIES DISPENSER. Tools Needed for Mounting SCS Dispenser Hammer Drill with 1/4, 1/8, 9/32 and 5/32 Diameter Bits Pliers

PeroxiDraw Dispenser

ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER IS NOT IN USE.

INSTALLATION INSTRUCTIONS DEMA BLEND CENTER MODEL B-GAP, T-GAP

DEMA SINGLE-FEED MODEL: 651GAP& 651GAP-1 INSTALLATION INSTRUCTIONS

ICS Integrated Cleaning System. Rechargeable Battery

Dilution Control Systems. 2-Button Station Model OPERATION SERVICE PARTS CARE

23200 Navigator Dilution Control System 4 Button Model (NAV 4)

Compact Cleaning System

Technical Manual. Table of Contents

The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse.

I Button Chemical Dispenser. Overview. Installation Instructions

DEMA MODELS 606T INSTALLATION INSTRUCTIONS

DEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS

DEMA SPRAY CLEAN DISPENSERS MODEL 605T INSTALLATION INSTRUCTION

Spray Clean 606T-2 Installation Instruction

THANK YOU FOR CHOOSING BATHERBOX GETTING STARTED WHAT S IN THE BOX? N. Northview Ave Sioux Falls, SD 57107

Table of Contents. Introduction. KP1H Components... 2 Installation and Assembly

Intended Use: Explanation of Signal Word Consequences

DEMA SPRAY STATION II MODEL 606T-2 INSTALLATION INSTRUCTIONS

ALLSTAR DILUTION CONTROL SYSTEM MODEL 639AG-4-1ABC

SAFETY INFORMATION & INSTRUCTION MANUAL

DEMA MODEL 606T-WI INSTALLATION INSTRUCTIONS

Spray & Foam Dispenser Item #

Items # and #

DEMA MODEL 603T-WI INSTALLATION INSTRUCTIONS

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

ALWAYS FOLLOW ALL SAFETY PRECAUTIONS AS DIRECTED BY THE CLEANING CHEMICAL LABEL

DEMA MODEL 604T-WI INSTALLATION INSTRUCTIONS

SAM SPARTAN ACCURATE MEASURE DISPENSING SYSTEM INSTALLATION INSTRUCTIONS MODEL 681-3SAM 1. PARTS: A. SAM

J1000 and J2000. Installation & Operating Guide. IS66998 issc ECN 6884

SOLUTION STATION Instruction Manual

DEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION

DEMA RAPID FIRE MODELS 6300, , , , 6310, 6300H 6300E, 6300EH, &6310E INSTRUCTION SHEET

AQUA-LAB AX, BX, TX. CHEMICAL DISPENSING SYSTEM User Manual REV A reva0717

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS

DEMA SPRAY CLEAN MODELS: 241CDF & 241CDFT INSTALLATION INSTRUCTIONS

(Airgap)

DEMA SPRAY CLEAN MODELS: 244CDF & 244CDFT INSTALLATION INSTRUCTIONS

180 Lake Ave North Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

DEMA Model 294D Spray Foam INSTALLATION INSTRUCTIONS

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

DEMA SPRAY CLEAN MODELS: 244BC, 244BCE, 244BCP & 244BCT INSTALLATION INSTRUCTIONS

FRS Dispenser (Foam-Rinse-Sanitize) Model # ol Systems. Dilution Control OPERATION SERVICE PARTS CARE

Asepsis 21 Delivery Unit

TRIPLE FOAM INSTALLATION MANUAL Part # FOAMSTRMRTPL00X

CHEMICALS ONE-WASH ( ) fax (662) HYDROMINDERS HYDROMINDER TIP SELECTOR HYDROMINDERS

DAH Left Hand Hose Inlet Kit Instruction Sheet For Use with 700 SERIES DAH Dilution at Hand Blend Centers

180 Lake Ave North Paynesville, MN Phone: (320) MASTER MANUFACTURING MASTER GARDNER

STAINLESS STEEL DETERGENT INJECTOR AW

TABLE 1. * SPECIFY S Stainless Steel Knob Part No S or Part No ST (for tips) for pressure exceeding 700 PSI.

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

INSTALLATION INSTRUCTIONS

OWNER S MANUAL. ROTARY SURFACE CLEANER Models 105C, 105F, 105CW, & 105FW. Revision 2.01

Dilution Control Systems. Multi-Task Dispenser Model #421700PL OPERATION SERVICE PARTS CARE. Dema #i GAPDB-MC2

Remove the 3-11mm nuts holding mirror on. Don t drop the nuts!

OWNER S MANUAL Model: LG ( ) (15 Gallon Lawn & Garden Trailer Sprayer)

AQUA-LAB SD CHEMICAL DISPENSING SYSTEM. User Manual REV G revg0518

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

DEMA 951 FLUSH MANIFOLD WITH 24V DC VALVE INSTALLATION INSTRUCTIONS

UNI-SPRAY - CLAMP-ON NOZZLE SELECTION GUIDE -

Alpha Tech Pet, Inc. HydroMAID - "Mobile Automated Integrated Diluter" Rechargeable Battery

XP-300 Series Sprinklers Installation & Service Instructions

PRO ACID System. Service / Site : QUAL / France Référence : 0016 Version : V.04.0 Date version : 07/07/2014 Page : 1/9 USER GUIDE

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

BC632 / BCL632 BC635 / BC635

& PumpRight for PWM Control. Maximum Pump Flow and Application Rates. Max Flow GPM

123 Industrial Loop Road Paynesville, MN Phone:

Page 1 of 19. Part# /10/2006

DP-139 PUMP DIMENSIONS

UNIMIX EM. Operations Manual. Supplied by:

INSTALLATION INSTRUCTIONS

Washing station / Centrale PROWASH CA PISTOPLAV NOTICE TECHNIQUE / USER GUIDE

DIRECT-DRIVE PRESSURE WASHERS

OWNER S MANUAL Model: LG ( ) (25 Gallon Lawn & Garden Trailer Sprayer)

SHOP PRO FXP 95 UPGRADE KIT (REGULATED)

Installation Instructions

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

PENTECH, INC. BD Spray Gun. Operating Manual Parts Manual May, 2008 Issue 1. Plural Component, Impingement Mixing, Mechanical Purge Spray Gun

Instruction Book DeLaval Barrier Teat Dip Spray Extension Kit

ATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL

KJ4000LW Operating Instructions & Parts Manual NSN

Reference Manual FM-200 Series

MODEL: ATV Volt, 15 Gallon ATV Mounted Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Agxcel GX12i Chemical Injection System

Transcription:

PROMAX INSTRUCTION MANUAL One Hand Activation Single Product [1 gpm (4l/m) models only] One Hand Activation 4 Product [1 gpm (4l/m) models only] Button Activation Single Product [1, 4, 8 gpm (4, 16, 30 l/m) models] Button Activation 4 Product [1, 4, 8 gpm (4, 16, 30 l/m) models] WHAT S IN THE BOX : 1. Dispenser 2. Pick up tube - 13ft (4 m) (1 roll for each product) 3. Discharge hose (6.5ft (2 m) for 4 and 8 GPM or S shaped discharge tube for 1 GPM spray bottle fill) 4. Hose Hanger (only if hose 6.5ft is present) 5. Complete installation kit: - Plastic clamps (2 pcs for each product) - Metering tips (1 bag for each product) - Foot filter and non-return valve assembly (1 piece for each product) - Ceramic weight (1 piece for each product) - Anchors (3pcs) - Screws (3pcs) - Washers (3pcs) - Coupler (for ganging two or more units together) - ¾ male GHT Fitting - Adhesive Labels for product identification (1 chart for each product) ProMax Cod. 0000137667 rev. 1.1 1

TECHNICAL FEATURES : Water supply connection Possible from right or left Type of connection ¾ Female GHT Type of disconnection F-Gap (Flexible membrane) A-Gap (Physical, Visible Gap) Venturi flow rates 1GPM (4lt/m) (Gray) 4GPM (16lt/m) (Yellow) 8GPM (30lt/m) (Blue) Actuating systems Button Slide-up (one hand fill) No. of product inlets 1 (models B1 and S1) 4 (models B4 and S4) Maximum dimensions H = 8 ¾ (22 cm) W = 3 7/8 (10 cm) D = 4 ¾ (12 cm) Working pressure Temperature Notes READ CAREFULLY BEFORE INSTALLING: Min 15 PSI (1bar) Max 130 PSI (9bar) Ideal: 30-60 PSI (2 4bar) Max 160 F (70 C) Possibility of adding modules after installation MAXIMUM WORKING PRESSURE is 130psi (9bar) and is intended as a static pressure reached progressively. Water hammer pressures exceeding 130psi (9bar), resulting from the sudden opening of a water source or other causes within the facility, may damage the system. Use of an in line pressure reducer is advisable where these conditions are present. The water supply should be turned off when the system is not in use. The correct procedures for dispenser installations are provided. DO NOT INSTALL where the dispenser is directly exposed to vapours or chemical fumes. Do not position near sources of heat. PROTECT YOURSELF - wear protective clothing and eyewear when installing or maintaining the system, take specific precautions as necessary FOLLOW THE SAFETY AND HANDLING INSTRUCTION of the chemical manufacturer. DIRECT THE DISCHARGE HOSE ONLY INTO A SPECIFIC CONTAINER, not toward yourself or another person CALIBRATE THE DOSING as per the manufacturer s instruction This unit is supplied with an internal backflow prevention device to avoid water supply contamination. Local compliance standards may vary. Some jurisdictions may require a backflow prevention device at the system s water inlet. TO PREVENT SIPHONING and to comply with ASME A112.1.2, install the dispenser so the end of the discharge tube is a minimum 4 above the flood level of the sink or other fixed container. THE DISPENSER SHOULD BE INSTALLED approximately 5 ft (1,5 m) from the ground and near the chemical containers for convenient use DISCLAIMER: STATE OF MASSACHUSETTS 1. THESE DISPENSERS SHALL BE INSTALLED BY A MASSACHUSETTS LICENSED PLUMBER 2. THE INSTALLATION SHALL BE HARD PLUMBED USING PRODUCT APPROVED MATERIALS *(See Below) 3. THE PUBLIC WATER SUPPLIER SHALL BE CONTACTED REGARDING THE PROPER BACKFLOW PREVENTION DEVICE TO BE INSTALLED *Approved Materials: Attach a brass MALE-GHT x 3/8 Compression fitting to the hose swivel on the dispenser. Using a compression T run 3/8 copper tubing from the water supply to the 3/8 compression fitting at the dispenser. ProMax Cod. 0000137667 rev. 1.1 2

INSTALLATION OF A SINGLE UNIT : Step 1 Step 2 Step 3 Use the bracket as a template to mark the mounting hole pattern. Drill the hole for the supplied ¼ anchors and secure the bracket with the three supplied screws. Step 4 Attach the system to the bracket and slide it down Step 5.until the top tab clicks in place securing the system to the bracket Slide in the discharge hose (6.5ft or S tube) over the barbed fitting securing it into place Connect the water inlet supply hose land tighten firmly with pliers. ProMax Cod. 0000137667 rev. 1.1 3

INSTALLATION OF A MULTIPLE UNIT : Step 1A Step 2A Step 3A 2 1 To install a multiple unit system, start by installing the first bracket on the wall as illustrated in Step 1. Then slide the second bracket into the slot from top to bottom on the left side of bracket 1 until they are properly aligned and secure.. Unlock the left side of the first system by pulling the rear clip to its outward most position as shown and remove the end cap. Unlock the right side of the second system by pulling the clip to its outward most position and remove the water connection. Step 4A Step 5A Step 6A Insert the coupling nipple into the first unit as illustrated Connect the second unit to the first Apply the combined system on to the bracket and complete the installation as per step number 3 above. ProMax Cod. 0000137667 rev. 1.1 4

SUCTION HOSE AND TIP INSTALLATION : Step 7 Step 8 Step 9 Select a suitable tip and insert it completely into the barbed tip seat as shown. To determine the correct tip refer to the tip chart below. Connect the suction hoses by sliding completely over the barbed tip seat as shown CERAMIC WEIGHT Cut the tubing to the required length. Connect the yellow foot valve / filter in to the hose as shown above. Slide the ceramic weight over the tube and as far as possible over the barbed fitting on the yellow foot valve. Step 10 Tip calibration: 1. Fill a graduated cylinder with the concentrated product. 2. Using the chart in the manual, select and insert the tip closest to the desired dilution ratio. 3. Insert the pick up hose into the graduated cylinder. 4. Put the outlet tube into a open container and push the button or lever in order to activate the system. Draw up the product until Chemical graduated tank Water Water + Chemical tank the pick up tube is completely tank Chemical tank filled. 5. Switch the system off and insert the delivery hose in a 1 gallon (or 5 liter) container. 6. Mark the level of the product in the graduated container 7. Switch the system on again until the 1 gallon (or 5 liter) container is completely full. 8. Switch the system off and read the quantity of product in the graduated container. 9. The difference in the product levels for points 6 and 8 indicates the amount of product mixed per gallon (or liter). Step 11 Use a cable tie to secure the tube on the barbed tip seat. For a 4 product selector, repeat the operations from step 7 to 11 for each product ProMax Cod. 0000137667 rev. 1.1 5

HYDRAULIC FEATURES DILUTION RATIOS Note: The following dilution ratios should be considered only as an initial reference. Variable factors such as water flow/pressure, distance of product container to inlet fitting and product viscosity often require field adjustments. The dilution ratio refer to the dynamic pressure of 40 PSI (2,76bar) with water thin products. 1 GPM Model 4 lt/min Flex-Gap 4 GPM Model 16 lt/min STANDARD METERING TIP Tip color Diameter inch Oz/Gal gr/lt % Ratio Oz/Gal gr/lt % Ratio No tip \ 38,4 300 30% 2,3 :1 15,36 120 12% 7,3 :1 Grey 0,128 37,12 290 29% 2,4 :1 14,72 115 11,5% 7,7 :1 Black 0,100 33,28 260 26% 2,8 :1 14,08 110 11% 8,1 :1 Beige 0,070 26,88 210 21% 3,8 :1 10,24 80 8% 11,5 :1 Red 0,052 16,64 130 13% 6,7 :1 5,76 45 4,5% 21,2 :1 White 0,043 14,08 110 11% 8,1 :1 4,48 35 3,5% 27,6 :1 Blue 0,040 11,52 90 9% 10,1 :1 3,84 30 3,0% 32,3 :1 Tan 0,035 8,96 70 7% 13,3 :1 2,56 20 2% 49,0 :1 Green 0,028 6,40 50 5% 19 :1 1,92 15 1,5% 65,7 :1 Orange 0,025 5,12 40 4% 24 :1 1,28 10 1% 99,0 :1 Brown 0,023 3,84 30 3% 32,3 :1 1,23 9,6 1% 103,2 :1 Yellow 0,020 3,20 25 2,5% 39 :1 1 7,8 0,8% 127,2 :1 Aqua 0,018 1,92 15 1,5% 65,7 :1 0,74 5,8 0,6% 171,4 :1 Purple 0,014 1,28 10 1% 99 :1 0,45 3,5 0,4% 284,7 :1 Pink 0,010 0,64 5 0,5% 199 :1 0,18 1,4 0,1% 768,2 :1 Clear \ No hole No hole ULTRALEAN TIP Lime 0,009 0,54 4,2 0,42% 237 :1 0,17 1,3 0,13% 768 :1 Burgundy 0,008 0,45 3,5 0,35% 285 :1 0,13 1 0,1% 999 :1 Pumpkin 0,007 0,26 2 0,2% 499 :1 0,08 0,6 0,06% 1666 :1 Copper 0,006 0,13 1 0,1% 999 :1 0,04 0,3 0,03% 3332 :1 Note: The dilution data given are determined under 40PSI of pressure and 5.28 GPM flow rate. To set a desired flow rate, a pressure regulator may needed in cases where flow pressure is excessive. Where the minumum and maximum flow properties are not available, consult a plumber to remedy the situation. Flow volume needed from the pipe line to reach the optimal flow rate of the venturi: - Gray venturi 1GPM (4l/m) nominal flow rate Needs at least 4 GPM (16l/m) from the pipe line - Yellow venturi 4GPM (16l/m) nominal flow rate Needs at least 7 GPM (27l/m) from the pipe line - Blue venturi 8GPM (30l/m) nominal flow rate Needs at least 12GPM (45l/m) from the pipe line ProMax Cod. 0000137667 rev. 1.1 6

TROUBLE SHOOTING Problem Cause Solution System does not dispense solution Water flow won' t stop Activation valve is leaking 1. Water inlet strainer is clogged 1. Clean it or replace if necessary 2. Too much water pressure 2. Use a water pressure regulator in case of more than 130PSI (9Bar) water pressure 3. Insufficient water pressure 3. 15 PSI (1Bar) is the minimum required pressure. If not available consult a plumber 4. The venturi is clogged 4. Soak venturi in hot water and inspect visually, gently removing debris. Replace assembly if needed. 5. Activation valve is clogged by mineral 5. Soak the valve assembly in a solution of hot water and limescale remover. Replace assemly if needed. 1. Activation valve is clogged by minerals or other water borne debris 1. Soak the valve parts and valve seat in limescale remover to clean. Replace them if necessary 1. Valve cap not tight enough to seat 1. Firmly hand tighten the valve cap until leak stops. 2. Not properly positioned 2. Reposition the valve or change it if necessary Connections and end cap are leaking 1. Missing o-ring in the connection fitting and / or end cap 1. Apply the o-ring or replace the entire part 2. O-ring in the connections or end cap are damaged 2. Replace the o-rings or replace the entire end cap F-gap backflow prevent is leaking A-gap is spraying out and or leaking 1. Flexible membrane is damaged 1. Replace the backflow preventer 1.Limescale film or dirt on the A-gap s upper nozzle 1. Soak in hot water and limescale remover to remove buildup. Replace if necessary 2. Venturi coated with limescale or dirt 2. Soak in hot water and limescale remover to clean. Replace it if necessary 3. There is a buildup or clog in the discharge hose 3. Clean the hose to eliminate restriction 4. Discharge hose is above the dispenser 4. Make sure the discharge hose dispenses below the dispenser insuring no back pressure Improper concentration of chemical or no suction 1. Insufficient water pressure 1. 15 PSI (1Bar) is the minimum working pressure. Check plumbing options 2. Metering tip clogged 2. Replace tip 3. Foot valve clogged 3. Soak in hot water, hand clean or change it System continues to draw chemical after the valve is closed 4. Venturi or backflow preventer clogged 4. Soak in hot water or limescale remover to clean. Replace it if necessary 5. Air leak in chemical pick up tubing line 5. Check the entire line. Replace the tubing check the connections and cable tie 6. Product is too thick 6. Change the pick up hose. Switch to a bigger diameter. (need ¼ x 5/16 coupler) 7. Product container is too far from the system 7. The standard installation is positioning the tank under the system, 5ft (1.5m) max 8. Excess concentration 8. Tip is not the correct one or not seated fully. (Pressure variations can require adjustment from chart recommendation) 1. Chemical tank is positioned higher than the dispenser causing siphoning 1. Move chemical container below the dispenser discharge point ProMax Cod. 0000137667 rev. 1.1 7

Spare parts N Description 1 Housing (rear + front) Clear Faceplate 1P Button Clear Faceplate 1P Slide 2 Clear Faceplate 4P Button Clear Faceplate 4P Slide 3 Mounting bracket spare 4 Complete button spare kit 5 Complete slide spare kit 6 Complete selector spare kit 7 Complete activation valve spare kit Complete venturi gray spare kit 1GPM (4lt/min) 8 Complete venturi yellow spare kit 4GPM (16lt/min) Complete venturi blue spare kit 8GPM (30lt/min) 9 Complete backflow F-gap spare kit Complete A-gap & venturi 1 GPM (4lt/min) spare kit 10 Complete A-gap & venturi 4 GPM (16lt/min) spare kit A-Gap Nozzles 1 GPM (4lt/min) kit (10pcs) 11 A-Gap Nozzles 4 GPM (16lt/min) kit (10pcs) 12 Bottle ( S ) filling hose 13 Water inlet fitting kit 14 Inlet fitting kit 1product 15 Bucket filling hose 16 Top filter kit Note: contact Seko to order spare parts. ProMax Cod. 0000137667 rev. 1.1 8