RadioRA 2 Maestro Local Controls

Similar documents
HomeWorks QS Designer RF Maestro Local Controls

RadioRA 2 Maestro Local Controls

RADIORA2 C.L Multi-Location Dimmer 150W CFL/Led or 600W Inc/Hal 120V In White. 6 to 277 VAC lights/3 VAC fan/3 VAC light and fan

Maestro Wireless Dimmers and Switches

Vive Maestro Wireless Dimmers and Switches

HomeWorks QS RF C L Hybrid seetouch Keypads

Maestro Wireless Dimmers

Maestro Wireless Local Controls

Primary controls RadioRA 2 designer dimmers and switches

Maestro Wireless Dimmers and Switches

INCANDESCENT/HALOGEN/MAGNETIC LOW VOLTAGE

Maestro C.L multi-location dimmer 150W CFL/LED or 600W. Inc/Hal 120V In White Vive Enabled

Maestro Wireless Dimmers and Switches

HomeWorksR QS Wired MaestroR Architectural Local Controls

Diva 250 W C L Dimmer

Dimmer for CFL and LED dimmable bulbs

Diva C L Dimmer. Wallbox Controls. Dimmer for CFL, LED, Halogen, and Incandescent dimmable bulbs.

Diva 250 W C L Dimmer

Wired Maestro Local Controls

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Dimmer, reverse-phase, 3-way/single-pole

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells

Diva 0 10 V Controls. Diva 0 10 V Control Wallbox Controls. Controls for 0 10 V LED Drivers and Fluorescent Ballasts.

Diva Dimmer - Gloss Finish, Fluorescent or LED Dimming with. Poles 1 Voltage Rating 277 0% to 90% humidity, non-condensing. Indoor use only.

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells

DVCL153PHWH 1P/3W CFL/Led Dimmer White


Diva Dimmer - Gloss Finish, Fluorescent or LED Dimming with

Diva C.L Dimmer - Gloss Finish, C.L/LED (Screw-based),

Wired Vareo Local Lighting Controls

Model Number Description Voltage Load Type Minimum Load Maximum Load. Incandescent / Halogen. General Purpose Fan

Skylark C L Dimmer. Skylark. C L Dimmer. Wallbox Controls

DESIGNER SLIDE WITH PUSH ON/OFF SWITCH INCLUDES POWER FAILURE MEMORY, RFI SUPPRESSION CIRCUIT

Skylark C L Dimmer. Skylark. Wallbox Controls. Dimmer for CFL and LED dimmable bulbs.

Touch the future of lighting control

TOUCH THE FUTURE OF LIGHTING CONTROL

Skylark Contour C L Dimmer

Skylark C L Dimmer. Skylark. C L Dimmer. Wallbox Controls

Ariadni 250 W C L Dimmer

Lumea C L Dimmer. Wallbox Controls

Skylark Contour C L Dimmer

Installation Instructions Please Read Before Installing. Overview. Important Notes. Designer-Style Maestro Remotes HD-RD, -RS 120/127 V ~, 50/60 Hz

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells

AYCL153PHWH 1P/3W CFL/Led Dimmer White

AYCL153PHWH 1P/3W CFL/Led Dimmer White. Ariadni CÂ L Dimmer, CFL/LED (Screw-based),

Controls. CONTROLS AND ACCESSORIES PRODUCT FAMILY FEATURES DIMMERS DIMENSIONS SPECIFICATION SERIES STANDARD FEATURES

Ceana dimmers. Traditional wallplate opening in (73 mm)

PD3PCLWH Table/Floor Lamp Dimmer

Installation Instructions

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystem Dimming Module

Square-Style Faceplates

Phase-Adaptive Power Module

Switching Power Module

Frequently Asked Questions

Phase-Adaptive Power Module with 3-Wire Fluorescent Input

GVR GROUPS. Control4 Outlet Dimmer and Switch. Control4 Wireless Outlet Dimmer LOZ-5D1 Control4 Wireless Outlet Switch LOZ-5SI

DIN Power Module - Phase Adaptive

Lutron l LyneoTM. slide dimmer. Special features

SO-2BON- - SO-2BOI- - 2-Button Wallstation with Occupant Sensor Connection

SO-SVCN- - GRAFIK Systems Sivoia QEDTM Controller

Residential Systems Control of LED Lighting (120V)

Ecosystem 5 Percent 3-Wire and Ecosystem Digital Link Controlled T4 Compact, 1 Lamp, Ballast Factor Of 0.95, K-Can, Studded, 26/32W

CIRRUS CEILING WALL WASH WITH REMOTE POWER

Fluorescent (non-capacitive) Metal Halide 10A. 2 Any load circuit can be connected to any phase.

EcoSystem Multiple Control Input Ballasts

Phase-Adaptive Power Module

L4B-F-RF Round Fixed Frame In BRO

0.25" (0.64cm) Grip Jack Connector 2WDC WDC Lumen values are based on the 3000K LED test.

Installation Instructions

Catalog Volume 1. Addendum Custom Architectural Wallplates

Hi-lume LED Overview. LED Dimming Driver Hi-lume LED Architectural Dimming

86mm [3.386 ] Lyneo preset dual For incandescent loads, 2 way Max. 2 x 250 W, min. 2 x 40 W

GRX-TVI Ten Volt Interface

EcoSystemR Multiple Control Input Ballasts

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

LCP128T Spec Grade Dimming System

Remote Power Supplies * & Dimmers (Sold Separately): Electronic Low Voltage Dimming (ELV) 0-10 Volt Dimming (0-10V) Lutron

CIRRUS CEILING SQUARE 1 WITH REMOTE POWER

GRX-TVI Ten Volt Interface

EcoSystem Multiple Control Input Ballasts

MXS Matrix Small BRO

GRX-TVI Ten Volt Interface

MXS Trimless Matrix Small XTM

Lutron Sensor Solutions. Maestro occupancy sensing switch. Lutron Sensors. Reliable solutions for any space.

Adaptive Power Module

Adaptive Power Module

3-Wire Control, 120, 277 Volt T5 Twin Tube Compact Lamps, T4 Quad Tube and T4 Triple Tube

RTA-RX-F-SC and RTA-RX-F-SC-347

CIRRUS SUSPENSION WALL WASH WITH REMOTE POWER, END FEED

Cylindrix III. Recessed Multiples

Cylindrix III. Recessed Multiples

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

Description Wall Plate, 4-Dimmer/Dimmer Switch/Fan Speed Controller; 4 Gangs; Ivory; Nova T Brand; Dimmer Model

3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps

MOUNTING: Swing out lugs permit from below mounting into ceiling up to 1 1/2 (38 mm) thick LABELING: Approved to UL standards as tested by CSA

MOUNTING: Swing out lugs permit from below mounting into ceiling up to 1 1/2 (38 mm) thick LABELING: Approved to UL standards as tested by CSA

D4B-F-R 3 Series Round Frame In BRO

OUTDOOR TRACK. LABELS Assembled in America

Dimmer / 2-Way Dimmer

2-Way Dimmer (1 Gang)

GP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

Transcription:

RadioRA Maestro local controls function much like standard dimmers and switches, but can be controlled as part of a lighting control system. Local lighting controls are useful in locations where single circuits of lighting need to be dimmed or switched. Local fan speed controls are useful in locations where control of a single ceiling paddle fan is needed. RadioRA Maestro dimmers incorporate advanced features such as fade on / fade off, delayed long fade to off, and rapid full on. RadioRA Maestro local controls include a Front Accessible Service Switch (FASS) for safe lamp replacement. RadioRA Maestro local controls install in single-pole or multi location applications. Remote dimmers / switches are available for multi location control. Use Lutron Designer (Claro or Satin Colors) wallplates or designer-style wallplates from other manufacturers. Wallplates are sold separately. Lutron Claro and Satin Colors wallplates snap on with no visible means of attachment. RadioRA Maestro local controls support color change kits. Dimmer Switch Fan Speed Remote Switch

Model Numbers Dimmers Incandescent / Halogen / MLV (0 V~) RRD-6CL-XX RRD-6ND-XX RRD-6D-XX RRD-0D-XX RRD-0ND-XX 600 W / 600 VA (Incandescent / Halogen / MLV) or 50 W (CFL / LED) Two-Wire Dimmer* 600 W / 600 VA Wire Dimmer 600 W Incandescent / Halogen, 600 VA MLV 000 W / 000 VA Dimmer 000 W / 000 VA Wire Dimmer Incandescent / Halogen / MLV / ELV (0 V~) RRD-6NA-XX 3-Wire Fluorescent / LED (0 77 V~) RRD-F6AN-DV-XX Switches 600 W / 600 VA Wire Adaptive Dimmer 6 A Wire Dimmer Lighting and Motor s (0 V~) RRD-8ANS-XX Lighting and Motor s (0 77 V~) RRD-8S-DV-XX Fan Speed Control Single ceiling paddle fan only (0 V~) RRD-ANF-XX 8 A Light, /4 HP 5.8 A Motor Wire Electronic Switch 8 A Light, /0 HP 3 A Motor Two-Wire Electronic Switch A Fan Speed Control Remotes (for multi-location installations) RD-RD-XX RD-RS-XX RD-RD-77-XX RD-RS-77-XX (0 V~) Remote Switch (0 V~) (77 V~) (for use with -F6AN-DV only) Remote Switch (77 V~) (for use with -8S-DV only) Color Change Kits RK-D-XX RK-S-XX RK-AD-XX RK-AS-XX RK-F-XX Dimmer (-6CL, -6D, -6ND, -0D, -0ND, -6NA, -F6AN-DV) Switch (-8ANS, -8S-DV) (-RD) Remote Switch (-RS) Fan Speed Control (-ANF) * Go to www.lutron.com/ledtool to see all compatible CFL / LED lamps. Note: XX in the model number represents color / finish code. See Colors and Finishes at end of document.

Specifications Model Numbers Power Typical Power Consumption Regulatory Approvals Environment Communications ESD Protection Surge Protection Power Failure Mounting Wiring Warranty Dimmer: RRD-6CL, RRD-6D, RRD-6ND, RRD-0D, RRD-0ND, RRD-6NA, RRD-F6AN-DV Switch: RRD-8ANS, RRD-8S-DV Fan Speed Control: RRD-ANF Remote: RD-RD, RD-RS, RD-RD-77, RD-RS-77 0 V~ : -6CL, -6D, -6ND, -0D, -0ND, -6NA, -ANF, -8ANS, -RD, -RS 0 77 V~ 50 / 60 Hz: -F6AN-DV, -8S-DV 77 V~ : -RD-77, -RS-77 Dimmer / Switch / Fan Speed Control: 0.6 W Test conditions: load is off and nightlight mode is enabled. / Switch: 0 W Test conditions: load is off. UL, CSA (all except -6CL and -6NA), cul (-6CL and -6NA only), NOM, FCC, IC, COFETEL, ANATEL (all except -6ND, -6NA and Remotes) Ambient operating temperature: 3 F to 04 F (0 C to 40 C), 0% to 90% humidity, non-condensing. Indoor use only. Dimmers and switches communicate with the system through Radio Frequency (RF) and must be located within 30 ft (9 m) of a repeater. Remote dimmers/switches are not required to be within a specific range of a repeater. System devices operate on frequencies between 43.0 MHz and 437.0 MHz. Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 6000-4-. Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C6.4-99 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits. Power failure memory: should power be interrupted, the control will return to its previous state when power is restored. Requires a U.S. wallbox. 3 ½ in (89 mm) deep recommended, ¼ in (57 mm) deep minimum. Uses conventional 3-way and 4-way wiring. www.lutron.com/technicaldocumentlibrary/warranty.pdf 3

Design Features Dimmer On a single-tap, lights fade ON or OFF. On a double-tap, lights go to full ON. When ON, press and hold the tapswitch to engage the delayed long fade to OFF. Light levels can be fine-tuned by pressing and holding the dimming rocker until the desired light level is reached. and two-wire dimmers available. Switch On a single-tap, lights or motors turn ON or OFF. and two-wire switches available. Fan Speed Control On a single-tap, fan turns ON or OFF. Fan speeds can be selected by pressing and holding the fan speed control rocker until the desired fan speed is reached. Controls one paddle-type ceiling fan (Permanent split-capacitor motor) up to A. Not for use with shaded-pole type motors (e.g., bath exhaust fans). Provides 4 quiet speeds plus OFF. Not for use with fans that have integrated fan speed and/or light control modules. Requires a neutral connection. 4

Dimensions All dimensions are shown as: in (mm) Front View Side View Side View Side View -ANF only -RD-77 and -RS-77 only 4 6 (9) 5 6 (75) 5/6 (8) 8 (30) 5/6 (8) 6 (43) 5/6 (8) 3 8 (35) Mounting and Parts Identification Control Mounting Screws Adapter Mounting Screws Wallbox Control Wallplate Adapter Wallplate Adapter / Wallplate purchased separately Wallplate 5

Ganging and Derating When combining controls in the same wallbox, derating is required (see Type and Capacity). No derating is required for remote dimmers, remote switches, or fan speed controls. -8ANS, -RD-77, and -RS-77 have fins that need to be removed for multigang installations. Type and Capacity Do not remove outside fins on ends of ganged controls (shaded areas). A B B B C B Type Minimum A Not Ganged 6 B End of Gang RRD-6CL Incandescent/Halogen/CFL/LED see Mixing Lamp Types, page 8 MLV,3 50 W/ VA 450 W/600 VA 400 W/500 VA 300 W/400 VA RRD-6D Incandescent/Halogen 50 W 600 W 500 W 400 W MLV 50 W/ VA 450 W/600 VA 400 W/500 VA 300 W/400 VA C Middle of Gang Connection RRD-6ND,4 LED Varies 5 50 W 50 W 50 W Incandescent/Halogen 0 W 600 W 500 W 400 W MLV 0 W/ VA 450 W/600 VA 400 W/500 VA 300 W/400 VA RRD-0D Incandescent/Halogen 50 W 000 W 800 W 650 W MLV 50 W/ VA 800 W/000 VA 600 W/800 VA 500 W/650 VA RRD-0ND,4 LED Varies 5 50 W 50 W 50 W Incandescent/Halogen 0 W 000 W 800 W 650 W MLV,3 0 W/ VA 800 W/000 VA 600 W/800 VA 500 W/650 VA RRD-6NA,4 LED Varies 5 50 W 50 W 50 W Incandescent/Halogen/ELV 5 W 600 W 500 W 400 W MLV,3 5 W/VA 450 W/600 VA 400 W/500 VA 300 W/400 VA Dimmer Type: -6CL: designed for use with permanently-installed incandescent, MLV, tungsten halogen, CFL, or LED only. -6D, -6ND, -0D, -0ND: designed for use with permanently-installed incandescent, LED, MLV, or tungsten halogen only. -6NA: designed for use with permanently-installed incandescent, LED, ELV, MLV, or tungsten halogen only. Note: Do not install dimmers to control receptacles or motor-operated appliances. Low-Voltage Applications: -6CL, -6D, -6ND, -0D, -0ND: use with magnetic (core and coil) low-voltage transformers only. Not for use with electronic (solid-state) low voltage transformers. -6NA: use with electronic (solid-state) or magnetic (core and coil) transformers; do not mix ELV and MLV load types on a single control. Operation of a low-voltage circuit with lamps inoperative or removed may result in transformer overheating and premature failure. Lutron strongly recommends the following: Do not operate low-voltage circuits without operative lamps in place. Replace burned-out lamps as soon as possible. Use transformers that incorporate thermal protection or fused transformer primary windings to prevent transformer failure due to overcurrent. 3 Do not mix CFL or LED loads with MLV loads. 4 Power Boosters / Interfaces: -6ND, -0ND, -6NA can be used to control power boosters / load interfaces. For a list of compatible power boosters / load interfaces see Compatible Power Boosters and Interfaces, page 8. 5 Minimum load depends on lamp and is not limited to a particular wattage. Refer to the LED Product Selection Tool at www.lutron.com/ledtool Continued on next page... No No Yes No Yes Yes

Type and Capacity (continued) Do not remove outside fins on ends of ganged controls (shaded areas). A B B B C B Type RRD-F6AN-DV,,3 Fluorescent/LED Drivers Minimum A Not Ganged B End of Gang 0.05 A 6 A 5 A 3.5 A ballast 60 ballasts 50 ballasts 35 ballasts C Middle of Gang Connection RRD-ANF 4 Ceiling Fan 0.083 A A A A Yes RRD-8ANS,5 Lighting 0 W 8 A 6.5 A 5 A Motor 0.08 A /4 HP 5.8 A /4 HP 5.8 A /6 HP 4.4 A RRD-8S-DV 5,6 Lighting 40 W/ VA 8 A Motor 0.4 A /0 HP 3 A 8 A (-gang); 7 A (3-gang) Note: Do not install dimmers to control receptacles or motor-operated appliances. Power Boosters / Interfaces: -F6AN-DV, -8ANS can be used to control power boosters / load interfaces. For a list of compatible power boosters / load interfaces see Compatible Power Boosters and Interfaces, page 8. Fluorescent Dimmer Type: -F6AN-DV: designed for use with permanently installed 3-wire 0 V~ or 77 V~ line voltage control fluorescent ballasts or LED drivers. Use with only Hi-lume, Hi-lume 3D, Hi-lume Compact SE, Eco-0, or EcoSystem (H3D-, FDB-, ECO-, HL3-, EC5-, L3D). Do NOT use with any other ballasts or drivers. Do not install to control receptacles or motor-operated appliances. 3 Maximum : The maximum load for the -F6AN-DV is either the derated load or the number of ballasts, whichever is LESS. 4 Ceiling Fan Application: -ANF Use to control one paddle-type ceiling fan (permanent split-capacitor). Use the ceiling fan s pull chain to set its speed to the highest setting. Do not use to control fans that use shaded-pole motors (e.g., bath exhaust fans). Do not use to control fans that have integrated fan speed controls (e.g., fans that have a remote control) unless the integrated control is removed from the ceiling fan. Do not connect to any other motor-operated appliance or to any lighting load type. Do not use to control a fan lighting load (e.g., light kit). 5 Switch Type: -8ANS, -8S-DV: designed for use with permanently installed 0 V~ incandescent, MLV, ELV, tungsten halogen, fluorescent, CFL, LED, or motor loads. -8S-DV can also be used with permanently installed 77 V~ MLV or fluorescent loads. 6 Shunt Capacitor: Some -8S-DV installations may require the use of a shunt capacitor; this is especially necessary for load types sensitive to leakage current (e.g., fluorescent ballasts). If load flickers, install a shunt capacitor. Optional shunt capacitor must be installed inside the load fixture or in a separate J-box. For shunt capacitor installation see Wiring Diagram 4, 9, or 0. 7 A Yes Yes No 7

Mixing Lamp Types Mixing lamp types (using a combination of CFL/LED, Incandescent/Halogen bulbs) and ganging with other dimmers or electronic switches may reduce maximum wattage as shown in the chart below. Example: If fins from one side of dimmer are removed and you have two 4 W bulbs installed (total CFL Wattage = 48 W), you may add up to 300 W of incandescent/halogen lighting. Do not remove outside fins on ends of ganged controls (shaded areas). A B B B C B Total CFL/LED Wattage A Not Ganged Total Incandescent/Halogen Wattage B End of Gang C Middle of Gang Connection RRD-6CL, 0 W + 50 W 600 W Or 50 W 500 W Or 50 W 400 W No W 5 W + 0 W 500 W Or 0 W 400 W Or 0 W 300 W 6 W 50 W + 0 W 400 W Or 0 W 300 W Or 0 W 00 W 5 W 75 W + 0 W 300 W Or 0 W 00 W Or 0 W 00 W 76 W 00 W + 0 W 00 W Or 0 W 00 W Or 0 W 50 W 0 W 5 W + 0 W 00 W Or 0 W 50 W Or 0 W 6 W 50 W + 0 W Or 0 W Or 0 W Dimmer Type -6CL is designed for use with permanently-installed incandescent, CFL, LED, MLV, or tungsten halogen only. Do not install dimmers to control receptacles or motor-operated appliances. Do not mix CFL and LED loads with MLV loads. Compatible Power Boosters and Interfaces Some local controls can be used to control power boosters or load interfaces. Up to three power boosters or load interfaces can be used with one control. See table below for a list of controls and compatible power boosters and load interfaces. Control Phase Adaptive Power Modules: PHPM-PA-0-WH; PHPM-PA-DV-WH 3-wire Fluorescent Power Modules: PHPM-3F-0-WH; PHPM-3F-DV-WH Switched Power Module: PHPM-SW-DV-WH 0 0 V Interface and Switching Module: GRX TVI RRD-6ND RRD-0ND RRD-6NA RRD-F6AN-DV RRD-8ANS preferred Only the GRX-TVI is compatible with the RRD-F6AN-DV at 77 V~. All other power modules are 0 V~ only. 8

Operation Dimmer Status LEDs (not on s) Indicate light level; glow softly as night light when light is off Tapswitch Tap on / off Dimming Rocker Press to brighten Press to dim FASS Front Accessible Service Switch Switch Status LED (not on Remote Switches) Indicates load status; glows softly as night light when light is off Tapswitch Tap on / off FASS Front Accessible Service Switch Or RD-77 and RS-77 only OFF ON Fan Speed Control Status LEDs Indicate speed level; glow softly as night light when fan is off Tapswitch Tap on / off Speed Control Rocker Press to increase speed Press to decrease speed FASS Front Accessible Service Switch Important Notice FASS: Front Accessible Service Switch To replace bulb, remove power by pulling the FASS out fully on all controlling devices. After replacing bulb(s), push the FASS back in fully to restore power to the control(s). 9

Wiring Diagrams Wiring Diagram Single-Location Installation without -6CL, -6D, -0D Dimmer Wiring Diagram Single-Location Installation with -0ND, -6ND, -6NA, -ANF, -8ANS Dimmer/Switch/Fan Speed Control Silver 0 V~ 0 V~ Wiring Diagram 3 Single-Location Fluorescent Dimmer Installation -F6AN-DV with Lutron Ballast/LED Driver Dimmer Wiring Diagram 4 Single-Location -Wire Switch Installation -8S-DV with Optional Shunt Capacitor Switch Silver White Lutron Ballast/LED Driver Optional 0 77 V~ 0 77 V~ Shunt Capacitor White Lutron Ballast/LED Driver Note: Bolded lines in diagrams indicate leads on products. When using controls in single-location installations, tighten the blue terminal. Do not connect the blue terminal to any other wiring or to ground. Optional Shunt Capacitor must be installed inside the load fixture or in a separate J-box. Shunt capacitor is included with -8S-DV. Continued on next page... 0

Wiring Diagrams (continued) Wiring Diagram 5 Multi-Location Installation without -6CL, -6D, and -0D with RD-RD or Dimmer or Dimmer Dimmer or Note: Dimmer can be installed in any location in the circuit. 0 V~ Wiring Diagram 6 Multi-Location Installation with, -0ND, -6ND, -6NA, and -ANF with RD-RD; -8ANS with RD-RS or Remote Switch or Remote Switch Dimmer/Switch/Fan Speed Control Silver 0 V~ Note: Bolded lines in diagrams indicate leads on products. Up to 9 s/remote Switches may be connected to the Dimmer/Switch/Fan Speed Controls. Total blue terminal wire length may be up to 50 ft (76 m). -Wire Dimmers/Switches/Fan Speed Controls must be connected on the side of a multi-location installation. Continued on next page...

Wiring Diagrams (continued) Wiring Diagram 7 Multi-Location Fluorescent Dimmer Installation, (0 V~) -F6AN with RD-RD and Lutron Ballast/LED Driver Dimmer Silver White Lutron Ballast/LED Driver 0 V~ White Lutron Ballast/LED Driver Wiring Diagram 8 Multi-Location Fluorescent Dimmer Installation, (77 V~) -F6AN with RD-RD-77 and Lutron Ballast/LED Driver Dimmer Red Red Silver White Lutron Ballast/LED Driver 77 V~ White Lutron Ballast/LED Driver Note: Bolded lines in diagrams indicate leads on products. Up to 9 s/remote Switches/Fan Speed Controls may be connected to the Dimmer/Switch. Total blue terminal wire length may be up to 50 ft (76 m). -Wire Dimmers/Switches/Fan Speed Controls must be connected on the side of a multi-location installation. Continued on next page...

Wiring Diagrams (continued) Wiring Diagram 9 Multi-Location -Wire Switch Installation (0 V~) -8S-DV with RD-RS and Optional Shunt Capacitor Remote Switch or Switch Remote Switch or Switch Switch or Remote Switch Note: Switch can be installed in any location in the circuit. Optional 0 V~ Shunt Capacitor Wiring Diagram 0 Multi-Location -Wire Switch Installation (77 V~) -8S-DV with RD-RS-77 and Optional Shunt Capacitor Remote Switch or Switch Remote Switch or Switch Switch or Remote Switch Note: Switch can be installed in any location in the circuit. Red/ Red/ /Red Optional 77 V~ Shunt Capacitor Note: Bolded lines in diagrams indicate leads on products. Up to 9 s/remote Switches/Fan Speed Controls may be connected to the Dimmer/Switch. Total blue terminal wire length may be up to 50 ft (76 m). Optional Shunt Capacitor must be installed inside the load fixture or in a separate J-box. Shunt capacitor is included with 8S-DV. 3

product specifications 3695l 08..7 RadioRA Maestro Local Controls Colors and Finishes Gloss Finishes Satin Finishes White WH Ivory IV Hot HT Merlot MR Plum PL Turquoise TQ Almond AL Light Almond LA Taupe TP Eggshell ES Bizcocho BI Snow SW Gray GR Brown BR Palladium PD Midnight MN Sienna SI Terracotta TC briar GB stone BG Mocha Stone MS Goldstone GS Desert Stone DS Stone ST Limestone LS BL Due to printing limitations, colors and finishes shown cannot be guaranteed to perfectly match actual product colors. Color chip keychains are available for more precise color matching: Gloss Finishes: DG-CK- Satin Finishes: SC-CK- Metal Finish (wallplate only) When using Stainless Steel wallplates, it is recommended that you order the control in Midnight (MN). Stainless Steel SS )Lutron, Lutron, Maestro, Claro, Satin Colors, Hi-lume, Eco-0, RadioRA, and EcoSystem are trademarks of Lutron Electronics Co., Inc., registered in the U.S. and other countries. RadioRa, FASS, and Hi-lume Compact SE are trademarks of Lutron Electronics Co., Inc. 4