Schmidt Mess- und Regeltechnik

Similar documents
Operating Instructions for Paddle Flowswitch Model: PPS-...

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

M-100 Adjustable flow switch with right-angle flow

Operating manual Separator

Assembly and operating Instructions. Bypass Flow Meter DST

Types K510 / K520 / K130 / K610 / K620 / K522 (Angle 90 ) Measuring ranges from -60 C to +200 C.

DG 023 DG 024 DG 025 DG 041 DG 042. Clogging Indicators

Operating Instruction for Flowmonitor. Model: DF-WM

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

Assembly and operating Instructions RA 60 / FA 60

Clogging Indicators. Description. Page 393. Application Monitoring the contamination of pressure and high pressure filters.

Assembly and operating Instructions Bypass Flow Meter DST

KOBOLD SV FLOWMETER/SWITCH. User Instructions

1000 Series Piston Type Differential Pressure Gauges

DG 060 DG 061 DG 062 DG 063 DG 064 for Pressure and High Pressure Filters Operating pressure up to 600 bar Response/switching pressure up to 5,0 bar

For industrial applications For marine applications With proximity switch. Piston type flow switches

GEWAS 181 A. Alarm- and protection device Leak-water detector

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Operating Instructions for Plastic Flow Meter. Model: KSK

OFFICINE OROBICHE S.p.A. 1/7 INSTRUCTION MANUAL FOR FLOW SWITCHES PL SERIES

Mounting and Operating Instructions EB 5868/5869 EN

PKP Prozessmesstechnik GmbH Borsigstraße 24 D Wiesbaden-Nordenstadt Tel.: ++49-(0) Fax: ++49-(0)

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Instruction Manual. Sewage lifting station compli 300

Angle seat valve with diaphragm actuator VZXA-...-M

Operating Instructions

FTB 372 Series Axial Turbine Flow Meter

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Flow Monitors 1007 Table of contents

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Assembly and operating Instructions

FLOW. control. switch measure. Flow Switches

IP 900 W/KS & IP 900 D/KS

SensoLyt 700 SensoLyt 700 SW

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Starting up hydraulic systems

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

SMB. Assembly and operating instructions Sprinkler measuring orifice SMB/SMB-OE. Sprinkler measuring orifice

EGQ 212: Duct transducer, CO 2 and temperature

8.50 Kampmann Equestrian Solarium Perfect Enhances the Vital Functions and the Immune System Table of Contents.

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

1 Safety instructions

Float switch For industrial applications, with temperature output Model RLS-3000

Read and understand this manual for safely usage.

Operating manual Vacuum Breaker

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Note: Boldrin reserves the right, to modify the gas meters without changing the request concerning accuracy and security. page 2

Short-tube VA flow meter SGK 1-3

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

user s manual Model number

Electronic Ballast EVG 2000-T

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Operating Instructions OPTISWITCH 4000 C with transistor output

Instruction Manual DP03 Plastic paddle-type flow switch with cable

Easytork Solenoid Valve IOM

LEVEL SWITCH WITH 1 FLOAT

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and

General Instructions and Inspection Instructions for Crane

Angle seat valve with piston actuator VZXA-...-K

Flap-Type Flow Meter Prall

Insertion magnetic inductive flowmeter

Nominal sizes: DN 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150 Pressure rating: PN 16. Product No. Nominal size Body connection

MAGNETIC FLOAT SWITCH

Compressed air counter DN

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Operating instructions Flow monitor SI / / 2013

Operating instructions Mechatronic flow sensor SBY /00 03/2011

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

INSTALLATION INSTRUCTIONS SWITCH HOUSING SUPPLIED ONLY AS AN ASSEMBLY OF ENCAPSULATED SWITCH & LEADS. FLOAT SUPPLIED ONLY WITH ENCAPSULATED MAGNET.

Flow switches Series AD/VH

Operating instructions Flow monitors SI5000 SI / / 2007

Installation and operating manual

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Smartloop Connection Set. Instructions for Use from 07/2008. en_int

K - Flow Meter with Float

These installation and maintenance instructions must be read in full and completely understood before the installation!

Appendix: Safety and application notes for... 15

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Thermal flow sensor TFS-35

Product. Information. A.u.K. Müller. Flow meter turbine, with shut-off device. Series Characteristics. Applications.

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Operating Instructions Garlock Butterfly Valves DN : mm / 2-24

Ultrasonic Leak Detector and Seal Control Device SONAPHONE R

Bowl feeder WV401-1 / Translation of operating and installation instructions

Level switches (two-term level controllers) ERH-xx-04,-06,-07,-16,-16.1 Description

Technical Manual Electrical Power Supply System T4002

SIKA Flow Switches -1-

Parker Hannifin GmbH & Co. KG Tube Fittings Division Europe Am Metallwerk 9, Bielefeld Phone Fax

Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

S003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Installation and Operating Instructions

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

Transcription:

Content 1. Preface 2 2. 3. 4. 5. 6. 7. 8. 9. Safety hints 2 Principle of operation 3 Installation 3 Electrical connection 4 Switch point adjustment 7 Maintenance 7 Fault finding hints 8 Specifications 9 1

1. Preface The flow monitors RVM/U prove themselves through reliability and simple handling. To use the advantages of the instrument to the full extend, please take notice of the following: Every person in charge of commissioning and operating this instrument must have read and understand this operation instruction and specifically these safety instructions! 2. Safety Instructions 2.1. General Safety Instructions The instructions contained in the operation instructions must be followed to ensure a safe operation of the instrument. Further, the additional legal and safety regulations for the individual application must be observed. Accordingly this applies to the use of accessories as well. 2.2. Application as Directed The instruments type RVM/U serve as monitors for continuous flow of liquids. Any other use counts as non-directed. If not indicated otherwise, the scaling of the instruments refer to water. Special applications where intermittent loads (e.g. cyclic operation) could occur should be discussed and checked with our technical stuff. The instruments type RVM/U must not be used as single source to avoid dangerous situations on machinery and in plants. Machinery and plants must be constructed in a way that faulty conditions do not lead the operators into dangerous situations. 2.3. Qualified Personnel The instruments type RVM/U must only be installed by qualified persons, who are capable of using these instruments in a professional manner. Qualified personnel are persons, who are familiar with the erection, installation, commissioning and operation of these instruments and who hold a corresponding qualification for this function. 2

3. Principle of Operation The instruments type RVM/U operate on the principle of the float type flow indicator. Through the flowing medium a float is set in motion, whose integrated magnets create a magnetic field. The position of the float is detected with the switch contact. The float is reset to the starting point by means of a spring, which allows the installation in any position in a system. The instruments are adjusted to the installation with flow from bottom to top. The weight of the float influences the measuring result, therefore a different mounting position will show discrepancies to the actual flow. 4. Installation 4.1. Process Connection Caution! To avoid the damage of the flow monitor or the installation the following requirements must be fulfilled under any circumstances: Suitable process connection has to be provided. Connection size to be checked. Thread depth to be checked. Suitable sealing material to be used (Liquid sealing material will damage the flow monitor, if it gets inside.). Professional sealing. 4.2. Environment Conditions The flow monitor must not be used as a supporting part in a pipe construction. The medium must not contain any solid particles. Magnetic particles will accumulate in the magnetic float and effect the function. Before employment of anti-freeze and anti-corrosive check compatibility. Warning! The following requirements must be adhered to, otherwise the function of the flow monitor will be affected or the measuring results will not be correct: External magnetic fields will influence the switch contact. Keep sufficient distance to magnetic fields (e.g. electric motors). Piping, process connections or supports made from ferromagnetic material influence the magnetic field of the flow monitor. Keep a distance of 100mm to those materials (e.g. steel). The accuracy is influenced by cross-section changes, branches or elbows in the piping. Provide a straightening section of 10x DN upstream and 5x DN downstream of the instrument. Never reduce the pipe diameter direct ahead of the instrument! With liquids ensure through suitable steps the deareation of the instrument. 3

5. Electrical Connection The switch contacts are potential free and do not need any supply. Attention! Switch contact and unit are matched. After the exchange of a switch contact a readjustment must be made. Kindly request the relevant instruction. Switch condition under No flow condition: Connection: normally open DIN 43650 2 1 M 12x1 4 1 Connection: change over DIN 43650 M 12x1 2 3 1 2 4 1 5.1. Standard Switch Connection Pin-allocation of the supplied socket (DIN 43650 Form A or C). The ground-pin is not used.. Important instruction: When using the socket DIN 43650, the ingress protection IP65 is only warranted in connection with a suitable cable diameter. For information on this subject please refer to page 8. 4

5.2. Switch Contact with Cable The individual cores of the cable are marked according to the above connection diagram. 5.3. Special Design On request, specially designed switch contacts (sockets, ready-made cables) can be supplied. 5.4. EEx-proof Switch Contacts Attention! For the connection of EEx-proof switch units special instructions apply, which must be followed! Pay attention to the hints in the separate operation instruction for EEx-proof switch contacts! 5.5. Contact Protection Arrangement Attention! The following requirements must be adhered to under any circumstances, otherwise the switch contact will be destroyed! The reed-contacts employed in the switch contacts are, due to their construction, very fragile against over load. Non of the values voltage, current and wattage must be exceeded (not even for a fractional moment). The danger of overloads exist by means of: inductive loads capacitive loads resistive loads Inductive load This kind of load will be caused by contactors, relais solenoid waves electric motors Danger: Voltage peaks during switch off (up to 10 times of the normal voltage) Preventive measure: (example) 5

Capacitive Load This kind of load will be caused by: extreme long leads capacitive consumption Danger: High current peaks during switch on of the switch contact (exceeding the normal current) Preventive measure: (example) Limiting the current by means of a resistor Resistive Load This kind of load will be caused by incandescent bulbs motor start up Danger: High current peaks during switch on of the switch contact, because the filament has low resistance at low temperatures. Preventive measure: (example) Limiting the current by means of a resistor or heating of the filament. Connection to SPS For the connection to high resistance devices (like SPS) a protection circuit is not necessary. 6

6. Switch Point Adjustment Loosen the lock screw of the switch contact. Shift the switch contact until the arrow on the switch contact is in coincidence with the desired switch point. Tighten the look screw of the switch contact. Hints The adjusted switch point corresponds to the switch off point of the switch contact with decreasing flow. The actual switch position can be checked by means of an universal tester. The above description of the adjustment refers to the normally open contact. 7. Maintenance Due to the few moving parts the instruments do not require much service. A functional check and service on a regular base will not only increase the lifetime and reliability of the instrument, but of the entire plant. The service intervals depend on the pollution of the media environmental conditions (e.g. vibrations) During maintenance, at least the following points should be checked: operation of the switch contact leakage test of the instrument free movement of the float It is the obligation of the user to lay down appropriate service intervals depending on the application. Hints The free movement of the float and the operation of the switch contact can be checked by varying the flow and observing the switch contact status. In most cases a purification can be achieved by flushing the instrument with clean media. In obstinate cases (e.g. calcareous deposits) cleaning can be done with commercial purifier, as long as the purifier is not aggressive against the material of the instrument. 7

8. Fault Finding Hints The switch contact does not react: The switch contact is permanent in break position. 1. No flow Check for medium flow. 2. Flow too low or switch contact adjusted to high Adjust switch point to a lower flow. Use instrument with different range. 3. Incorrect reduced (pipe diameter too small) Reduce according to section 4. 4. Float got stuck (polluted) Clean the instrument and ensure free movement of the float. 5. Switch contact faulty Eliminate the reason for the float (short circuit, overload) Exchange switch contact, refer section 5). The switch contact is permanent in made position. 1. Flow too high and switch contact adjusted too low Reduce flow Adjust switch contact to a higher flow 2. Float got stuck (polluted) Clean the instrument and ensure free movement of the float. 3. Switch contact faulty Eliminate the reason for the fault (short circuit, overload) Exchange switch contact Switch point does not match with actual flow. 1. No medium specific scale Request a correction table or medium specific scale. 2. Incorrect reduced Reduce according to section 4. 3. Instrument polluted Clean the instrument. 4. Instrument defect Return instrument for repair and calibration to the manufacturer 8

9. Specifications Operating data RVM/U-1 RVM/U-2 RVM/U-4 Pressure: brass PN 250 bar PN 300 bar PN 300 bar Pressure: stainless steel PN 300 bar PN 350 bar PN 350 bar Pressure drop 0,02 0,4 bar 0,02 0,3 bar 0,02 0,2 bar Temperature max. Accuracy 100 C (optional 160 C) +10% of final value Electrical data SPST N.O. SPDT SPST N.O. SPDT SPST N.O. SPDT IP65 (plug connection DIN43650 Form A or C) IP67 (with 1m sealed in cable) M 12x1 plug temperature max. 85 C Atex II 2G EEx m II T6 max. 80 C (2m sealed in cable IP67) 3A 100VA not available 2A EEx m II T6 max. 80 C Output signal 2A 1,5A 50VA (1) 30VA 30VA Max. 230V 3A Max. 125V 3A 2A 2A 1,5A 50VA (1) Max. 125V 1,5A 50VA 30VA 30VA Max. 200V 20VA Max. 125V 20VA The contact switches off, if minimum flow is below setpoint. not available not available Max. 200V 20VA (1) Max. 125V 20VA Power supply Cable diameter for IP65 6 8 mm not necessary (reed contacts) 4 6,5 mm Grade of pollution 2 (EN 61058-1) Other plug types or cable lengths on request (1) Minimum load 3VA 9

Materials Brass Stainless Steel Wetted parts Brass 1.4571 Spring (wetted parts) 1.4571 Magnets (wetted parts) hard-ferrite Seals (with reducers only) NBR (other on request) Viton (other on request) SW D B G DN T L RVM/U-4 17 17 47 ¼ 8 10 65 RVM/U-2 27 31 52 ½ 15 14 90 RVM/U-1 41 47 76 ¾ 1 20 25 21 17 152 130 Overall dimensions in mm All rights reserved 10