WL/WLM. Wide Range of Two-circuit Switches; Select One for the Operating Environment/Application

Similar documents
WL-N/WLM-N. Two-circuit Limit Switch/Long-life Two-circuit Limit Switch

WL-N/WL. Two-circuit Limit Switch. Two-circuit limit switches that can be selected to match the operating environment and application.

WL-N/WL. Two-circuit Limit Switch. Two-circuit limit switches that can be selected to match the operating environment and application.

Model Number Structure

Robust General-Purpose Limit Switch WL

Model Number Structure

WL-N. Two-circuit Limit Switch. Select the Best Two-circuit Switch for the Operating Environment and Application. Features

Safety Limit Switch

Pre-wired Models D4C- (1) (2) (3) (4)

WLG -N Series High Precision and High Sensitivity Limit Switches Discontinued; Replace with WL Series

Model Number Structure

Small Limit Switch D4V

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

2NC (slow-action) Direct. Model. opening

Manual Reset Limit Switch

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Safety Limit Switch

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Multiple Limit Switch

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Safety-door Switch. Ordering Information

D4DL. Guard Lock Safety-door Switch. Model Number Structure

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

2NC (slow-action) Direct. Model. opening

Compact plastic limit switches with positive opening mechanism

Safety Switches & Operator Controls

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Multiple Plunger Limit Switch

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

Hinged Safety Door Switch

Compact plastic limit switches with positive opening mechanism

HL (AZH) LIMIT SWITCHES

HL (AZH) Limit Switches

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

D4GS-N CSM_D4GS-N_DS_E_7_2

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

Limit Switches with Positive Opening Mechanism

OMRON Z LIMIT SWITCH

D4BS CSM_D4BS_DS_E_8_4

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

D4NH CSM_D4NH_DS_E_7_1

HL (AZH) Limit Switches

Best-selling Basic Switch Boasting High Precision and Wide Variety

BZSeries. Basic Switches

BZSeries. Basic Switches

LJASeries. Limit Switches with Positive Opening Mechanism

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

High sensitivity. Low current load type. type. Short plunger ~ Fine plunger ~ ~ Lever ~ Roller lever ~ Short roller lever ~

Miniature Limit Switches

D4BL. Guard Lock Safety-door Switch

CSM_D4N-_R_DS_E_6_1

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

1LS-J700 SERIES ULTRA LONG LIFE, GENERAL-PURPOSE COMPACT LIMIT SWITCHES

Basic Switches. BZ Series APPLICATIONS SELECTION GUIDE. High-quality switches with UL certification. *C-UL approval number: E96090.

Subminiature Basic Switch

DL (AZD1) Mini Limit Switches

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

Miniature Enclosed Limit Switch D4MC. Ordering Information. Economical, General-Purpose, Enclosed Switch. H High precision and long life (10,000,000

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

A22NK. Key-type Selector Switches

SL1Series. Compact Horizontal Limit Switches

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

FL series position switches

VL (AZ8) Limit Switches

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

LK Position Switches TECHNICAL DATASHEET.

D2SW. Sealed Subminiature Basic Switch. Ordering Information Model Number Legend D2SW-

Position switches FD series

Best-selling Basic Switch Boasting High Precision and Wide Variety

Miniaturized limit switches

Machine & Process Safeguarding Solution Selection Guide

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Position switches FR series

Standard Interlock Safety Switches

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Specifications. Model Number Structure

VL (AZ8) Limit Switches

Position switches FR series

Miniature Pre-Leaded Vertical Enclosed Switches

VERTICAL TYPE LIMIT SWITCHES (INCLUDES LAMP TYPE)

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Transcription:

Two-circuit Limit Switch/Long-life Two-circuit Limit Switch WL/WLM CSM_WL_WLM_DS_E_9_1 Wide Range of Two-circuit Switches; Select One for the Operating Environment/Application A wide selection of models are available, including the overtravel models with greater OT, indicator-equipped models for checking operation, low-temperature models, heat-resistant models, and corrosion-proof models. Microload models are added to the product lineup. Approved standards: EC/IEC, UL, CSA, CCC (Chinese standard). Contact your OMRON representative for information on approved models. Be sure to read Safety Precautions on page 9 to 42 and Safety Precautions for All Limit Switches. Features Standard Models Many Variations in Standard Limit Switches A Wide Range of Models The WL Series provides a complete range of Limit Switches with a long history of meeting user needs. Select environment-resistant specifications, actuators for essentially any workpiece, operating sensitivity matched to the workpiece, operation indicators to aid operation and maintenance, and various wiring specifications. Environment-resistant Models Select from Six Types of Environment Resistance The series includes Airtight Switches, Hermetic Switches, Heatresistant Switches, Low-temperature Switches, Corrosion-proof switches, and Weather-proof Switches. Select the one required by the onsite environment. Spatter-prevention Models Excellent Performance on Arc Welding Lines or Sites with Spattering Cutting Powder Ideal for Welding Sites Stainless steel and resins that resist adhesion of spatters are used to prevent troubles caused by zinc powder generated during welding. Long-life Models Mechanical Endurance of 0 Million Operations Long-life Models for High-frequency Applications Long life has been achieved by increasing the resistance to friction and creating better sliding properties in the head mechanism. Greater visibility is provided when setting with a fluorescent display for setting the stroke. Features Common to All Models DPDB Operation The double-pole, double-break structure ensures circuit braking. (NO)4 (NC)1 (NO) Degree of Protection; IP7 O-rings, cover seals, and other measures provide a water-proof, dripproof structure (IP7). Approved Standards to Aid Export Machines Various WL/WLM switches are approved by UL, CSA, TÜV, EN/IEC, and CCC making them ideal for export machines. High-precision Models Available in All Switch Types; Ideal for Position Control High-precision models achieve a very small movement to operation (approx. ) and a repeat accuracy that is twice that of basic models. Operation Indicators for Easier Daily Inspections* Confirm operation with a neon lamp or LED for easier startup confirmations and maintenance. * Operation indicators are provided on Indicatorequipped switches, Spatter-prevention Basic Switches, and Long-life Basic Switches. Za 2(NC) Models with Connectors to Reduce Wiring Reduce wiring with one-touch connection. Models with direct-wired and prewired connectors that make Switch replacement easier are also available. 1 2 Load Load 4 Operation indicator 1

Product Configuration WL/WLM Selection by Purpose WL Series WLM Series Standard Standard-load Switches WL@ Microload Switches WL01@ Basic Switches WLC@ Switches High-precision Switches WLGCA2 Protective WLCA2-@ Selection Points Effective for switching loads of 0.1 A, 12 VAC/0 VDC. General-purpose Switches Selection Points WLH@ Effective if the overall High-sensitivity movement is 80 or 90 Switches WLG@ when dog angle or deflection is absorbed. 90 Operation Switches WL@-2 WL@-2N Selection Points Provide twice the repeat accuracy as Basic Switches. Effective for positioning in machine tools. Selection Points Effective for protecting the operating status. Generalpurpose Indicator-equipped Switches: Neon lamps Operation indicators WL@-@LE Selection Points Indicator-equipped Switches: Light emitting diodes (LED) WL@-@LD Effective for confirming workpieces passing by on a conveyor or for confirming operation in dark locations. For standard models, add -LE or -LD. (Operation indicators cannot be used with some environment-resistant Direct-wired Switches Sensor I/O connectors WL@-@LDK@ Selection Points Pre-wired Switches WL@-@LD-M1@ Effective for reducing wiring work, WL@-@LD-AGJ@/-DGJ@ making maintenance easier, and WL@-@LD-DK1EJ@ preventing wiring mistakes. Airtight Switches WL@- Hermetic Switches WL@-19 WL@-140 WL@-141 WL@-14 WL@-RP40 Environment-resistant WL@-RP0 Heat-resistant Switches Selection Points WL@-TH Enable selection according to the Low-temperature Switches operating environment: water, oil, WL@-TC chemicals, high/low temperatures, etc. Corrosion-proof Switches WL@-RP Weather-proof Switches WL@-P1 Basic Switches WLCA2-@S Microload Switches Spatter-prevention WL01@-@S General-purpose Switches Switches WLH2-@S Selection Points High-precision Switches High-sensitivity Switches Effective for welding sites or spattering WLGCA2-@S WLG2-@S cutting powder. Basic Switches WLMCA2@ General-purpose Switches Long-life Switches WLMH2@ High-sensitivity Switches Selection Points High-precision Switches WLMG2@ With high mechanical durability of 0 WLMGCA2@ million operations, effective for high-frequency operation. 2

Tables of Models General-purpose Switches Spatter-prevention Switches Long-life Switches Heads (Roller levers only) Basic Type General purpose Model WLC@ With a Roller Lever Features Total travel (TT) 4 4 Head specifications One-side operation Possible *1 (Except for long-life models.) Head Any of 4 directions Spatter prevention Model WLCA2-@S Long-life Model WLMCA2@ Generalpurpose WLH@ is large, making setting the dog easier. Mounting is compatible with WLH2. 80 80 Not possible *2 Any of 4 directions WLH2-@S WLH2@ High-sensitivity WLG@ Operation is highly sensitive with only 10 pretravel. is large, making setting the dog easier. Mounting is compatible with WLG2. 80 80 Not possible *2 Any of 4 directions WLG2-@S WLMG2@, 90 operation Repeat accuracy is twice that basic models. 4 4 High-precision WLGCA2 Operation is highly sensitive Possible *1 with only pretravel. Ideal for positioning, e.g., When the dog throws the lever, the output is reversed and the reversed output is 90 Maintained WLCA2-@ held even after the dog passed. The original status is returned to only after the dog passed. *1. One-side operation means that three operational directions can be selected electrically, according to the change in direction of the operating plunger. The operating plunger is set for operation on both sides before delivery. *2. Those models for which one-side operation is impossible can only operate on both sides. Connectors and Conduits Any of 4 directions Either of 2 directions Any of 4 directions Any of 4 directions WLGCA2-@S WLMGCA2@ General-purpose Spatter-prevention Long-life Wiring type Connector/conduit specifications Model Model Model Direct-wired connector WL@-@LDK@ SC-2F/-4F Connector built-in WLM@-LDK@ Pre-wired connector Conduit (screw terminal) WL@-2 is large, making Not possible setting the dog easier. 90 90 *2 Mounting is compatible WL@-2N with WLCA2-2. Possible *1 WL@-@LD-M1@ WL@-@LD-@GJ@ WL@-@LD-DK1EJ@ WL@-@ WL@-@G1@ WL@-@G@ WL@-@Y@ WL@-@TS@ XS2H-series Pre-wired Connector builtin G1/2 with no ground terminal G1/2 with ground terminal Pg1. with ground terminal M20 with ground terminal 1/2 14NPT with ground terminal WL@-@S-M1@J-1 WL@-@S-DGJS0 WLM@-LD-M1J WLM@-LD-@GJ@ WLM@-LD

Environment-resistant Switches Item Environment-resistant Type Model Application Environment-resistant construction Applicable models Airtight seal WL@- WL@-19 WL@-140 Hermetic seal WL@-141 (Molded terminals/ Anti-coolant) WL@-14 WL@-RP40 Low-temperature * Heat-resistant * Corrosion-proof Weather-proof * WL@-RP0 WL@-TC WL@-TH WL@-RP WL@-P1 For uses in locations subject to cutting oil or water Can be used at a temperature of 40 C (operating temperature range: 40 to 40 C), but cannot withstand icing. Can be used in temperatures of 120 C (operating temperature range: to 120 C). For use in locations subject to corrosive gases and chemicals. For use in parking lots and other outdoor locations. Uses the W-10FB- Airtight Built-in Switch. Note: Use the SC Connector for the conduit opening. Refer to page 2 for information on the environment-resistant construction of Switches with Hermetic Seals. Uses a general-purpose built-in switch. Silicone rubber is used for rubber parts such as the O-ring, gasket, etc. Uses a special built-in switch made from heatresistant resin. Silicone rubber is used for rubber parts such as the O-ring, gasket etc. Diecast parts, such as the switch box, are made of corrosion-proof aluminum. Rubber sealing parts are made of fluorine rubber which aids in resisting oil, chemicals and adverse weather conditions. Exposed nuts and screws (except the actuator section) are made of stainless steel. Moving and rotary parts such as rollers are made of sintered stainless steel or stainless steel. The Head, box, and cover are yellow. Rubber parts are made from silicone rubber, which has a high-tolerance to deterioration over time and changes in temperature. Rollers are made of stainless steel to improve corrosion resistance. Exposed nuts and screws are made of stainless steel. All models except the lowtemperature and heat-resistant models Note: Models can be produced using standard actuators. All models except the lowtemperature and heat-resistant models Note: Models can be produced using standard actuators. Only the WLCA2, WLGCA2, or WLH2 can be produced for the WL@-141 and WL@-14. All models except airtight seal, hermetic seal, heatresistant, corrosion-proof, and indicator-equipped models All models except airtight seal, hermetic seal, heatresistant, corrosion-proof, and indicator-equipped, nylon roller (WLCA2-2N), seal roller models, and resin rod (WLNJ-2) models All models except overtravel (90 operation), fork lever lock (WLCA2-41 to - 4), low-temperature, heatresistant, and indicatorequipped models Only basic (WLCA2/CA12/ CL), general-purpose overtravel (WLH2/H12/HL) and high-sensitivity overtravel (WLG2/G12/GL) models (excluding heat-resistant models). * Weather Resistance, Cold Resistance, and Heat Resistance Silicon rubber is used to increase resistance to weather, cold, and heat. Silicon rubber, however, can generate silicon gas. (This can occur at room temperature, but the amount of silicon gas generated increases at higher temperatures.) Silicon gas will react as a result of arc energy and form silicon oxide (SiO2). If silicon oxide accumulates on the contacts, contact interference can occur and can interfere with the device. Before using a Switch, test it under actual application conditions (including the environment and operating frequency) to confirm that no problems will occur in actual. 4

Selection Guide With the WL Series, OMRON will combine the switch,, and wiring method required to build the ideal switch for your application. The WL Series consists of four basic types: General-purpose, Environment-resistant, Spatter-prevention, and Long-life Switches. WLCA2 Switches can be used for the most common applications. According to Operating Environment Environment Key specifications Models Ambient operating temperature Normal High-temperature Low-temperature 40 C 10 C Water-resistant to IP7. + C +40 C +80 C +120 C To increase heat resistance, the rubber material (silicon rubber) and the material of the built-in switch have been changed. To increase resistance to cold, silicon rubber and other measures are used. WL@ WLM@ WL@-TH WL@-TC General-purpose Switches Long-life Switches Heat-resistant Switches *1 Low-temperature Switches *1 Operating environment Outdoors Chemicals and oil WL@-P1 WL@-RP Weather-proof Switches *1 Corrosion-proof Switches *1 Water drops and mist Uses an airtight built-in switch. WL@- Airtight Switches *1 Constant water drops and mist Constant water drops or splattering cutting powder Coolant Spattering from welding Rubber parts are made from silicone rubber, which has a high-tolerance to deterioration over time and changes in temperature. Rollers are made of stainless steel to improve corrosion resistance. Exposed nuts and screws are made of stainless steel. Corrosion-proof aluminum diecast has been used for the housing, fluorine rubber has been used for rubber parts, and stainless steel has been used for screws and nuts (except for actuator) to increase resistance to oils, chemicals, and weather. Cables attached. Uses a general-purpose built-in switch. The case cover and conduit opening are molded from epoxy resin to increase the seal. The cover cannot be removed. Cables attached. Uses an airtight built-in switch. The case cover and box interior are molded from epoxy resin to increase the seal. The cover cannot be removed. The SC connector can be removed, so it is possible to use flexible conduits for the cable. Cables attached. Uses an airtight built-in switch. The cover screws, case cover, box interior, and conduit opening are molded from epoxy resin to increase the seal. (The cover cannot be removed.) Cables attached. Uses an airtight built-in switch. The cover screws, case cover, box interior, conduit opening, box head, and head screws are molded from epoxy resin to increase the seal. (The cover cannot be removed.) The Head opening is protected from cutting powder. -141: The Head section is molded from epoxy resin; Head direction cannot be changed. -14: The Head section is molded from epoxy resin; Head can be in any of 4 directions. Cables attached. Uses an airtight built-in switch. The case cover, box interior, conduit opening, and head screws are molded from epoxy resin to increase the seal. (The cover cannot be removed.) Rubber parts are made from fluorine rubber to increase resistance to coolant. To prevent spatter during welding, a heat-resistant resin is used for the indicator cover and screws and rollers are all made from stainless steel. WL@-19 Hermetic, Molded-terminal Switches *1, *2 WL@-RP40 Hermetic, Molded-terminal Switches *1, *2 WL@-140 Hermetic, Molded-terminal Switches *1, *2 WL@-141, -14 Hermetic, Molded-terminal Switches *1, *2 (Only the WLCA2, WLG2, WLGCA2, and WLH2 can be produced.) WL@-RP0 Hermetic, Molded-terminal Switches *1, *2 WL@-S Spatter-prevention Switches *1. Not all functions can be combined with environment-resistant switches. Refer to the applicable models on the previous page. *2. Refer to page 2 for information on the construction of Hermetic Switches.

According to Application Conditions Conditions Key specifications Models Durability Load Switching standard loads Switching microloads Normal durability Long-life 10 A at 12,20, or 00 VAC 0.8 A at 12 VDC 0.4 A at 20 VDC 0.1 A at 12 VAC, resistive load 0.1 A at 0 VDC, resistive load Mechanical: 1 million operation min. (10 million operation min. for overtravel general-purpose or high-sensitivity models or flexible rod models) Mechanical: 0 million operation min. WL@ WL@-S WLM@ WL01@ WL01@-S WL@ WL@-S WLM@ General-purpose Switches Spatter-prevention Switches Long-life Switches General-purpose Microload Switches Spatter-prevention Microload Switches General-purpose Switches Spatter-prevention Switches Long-life Switches According to Ease of Installation and Maintenance Conditions Key specifications Models Wiring specification Operation indicator Daily inspections and maintenance checks Screw tightening and installation One-touch connector attachment Connector attachment in control and relay boxes Switching light-on between operating/not operating. (Switching not possible for models with molded terminals.) Neon lamp 12 to 20 VAC Switching light-on between operating/not operating. (Switching not possible for models with molded terminals.) LED 10 to 11 VAC/DC Screw terminals. No ground terminal. Conduit size: G1/2 Screw terminals. Ground terminal. Conduit size: 4 sizes Direct-wired connector, 2-conductor. Greatly reduces wiring work. Water-proof to IP7. Direct-wired connector, 4-conductor. Greatly reduces wiring work. Water-proof to IP7. Pre-wired connector, 2-conductor. Greatly reduces wiring work. Water-proof to IP7. Pre-wired connector, 4-conductor. Greatly reduces wiring work. Water-proof to IP7. WL@-LE General-purpose, Indicator-equipped (Neon Lamp) Switches WL@-LES Spatter-prevention, Indicator-equipped (Neon Lamp) Switches WL@-LD General-purpose, Indicator-equipped (LED) Switches WL@-LDS Spatter-prevention, Indicator-equipped (LED) Switches WL@ WLM@ WL@ General-purpose Switches Long-life Switches General-purpose Switches WL@-@LDK1 General-purpose, Direct-wired Connector Switches WLM@-LDK1 Long-life, Direct-wired Connector Switches WL@-@LDK4 General-purpose, Direct-wired Connector Switches WLM@-LDK4 Long-life, Direct-wired Connector Switches WL@-@LD-M1J General-purpose, Pre-wired Connector Switches WL@-@S-M1J-1 Spatter-prevention, Pre-wired Connector Switches WLM@-LD-M1J Long-life, Pre-wired Connector Switches WL@-@LD-@GJO General-purpose, Pre-wired Connector Switches WL@-@S-@GJSO Spatter-prevention, Pre-wired Connector Switches WLM@-LD-@GJO Long-life, Pre-wired Connector Switches

According to Form of Operation Detection object Key specifications Models s Operation angles General Passing dogs Passing dogs, high sensitivity Passing dogs High precision Dogs and workpieces (Mounts in any of 4 directions) Adjustable between dog and lever Dogs or workpieces with large deflection TT (total travel) R8 R0 R R2 to 89 2 to 140 0 to 80 427. 4 80 80 90 PT (pretravel) 4 1 80 80 90 WLCA2-2 Short lever 1 10 4 4 2 WLCA2-2N 20 One-Horizontal operation possible. (WLCA@ only) Head mounts in any of 4 directions. Medium lever One-Horizontal operation possible. (WLCA@ only) Head mounts in any of 4 directions. Long lever One-Horizontal operation possible. (WLCA@ only) Head mounts in any of 4 directions. One-Horizontal operation possible. (WLCA@ only) Head mounts in any of 4 directions. One-Horizontal operation possible. (WLCL only) Head mounts in any of 4 directions. One-Horizontal operation not possible. Head mounts in any of 4 directions. One-Horizontal operation not possible. Head mounts in any of 4 directions. Head mounts in any of 4 directions. WLCA2 WLCA2-@S WLMCA2 WLH2 WLH2-@S WLMH2 WLG2 WLG2-@S WLMG2 WLCA2-2 WLCA2-2N General-purpose Switches Spatter-prevention Switches Long-life Switches General-purpose Switches Spatter-prevention Switches Long-life Switches General-purpose Switches Spatter-prevention Switches Long-life Switches General-purpose Switches General-purpose Switches WLGCA2 General-purpose Switches WLGCA2-@S Spatter-prevention Switches WLMGCA2 Long-life Switches WL@2 WL@2-@S WLM@2 WL@2-7 WL@2-8 WL@12 WL@L WLHAL4 WLHAL WLCA2-41 Roller Lever s Roller Lever s Roller Lever s Roller Lever s Roller Lever s Adjustable Roller Lever s Adjustable Rod Lever s Adjustable Rod Lever Rod Spring Lever Fork Lever Lock Round-trip operation of passing dogs Head mounts in any of 4 directions. Head mounts in any of 4 directions. WLCA2-42 WLCA2-4 Fork Lever Lock Fork Lever Lock Head mounts in any of 4 directions. WLCA2-44 Fork Lever Lock WLD Top Plunger Head mounts in any of 4 directions. WLSD Horizontal Plunger Cams or workpieces with vertical movement Head mounts in any of 4 directions. WLD WLSD Top-ball Plunger Horizontal-ball Plunger Available in sealed models. (WLD28@) WLD2 WLD28 Top-roller Plunger Sealed Top-roller Plunger WLSD2 Horizontal-roller Plunger 7

Application Examples WL/WLM Positioning on Production Lines High-precision Positioning of Machine Tools Positioning on Suspended Conveyors Pallet Detection in Arc Welding Lines Multilevel Car Parking Towers Limit Detection is Transport Systems 8

Model Number Structure Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.) General-purpose and Environment-resistant Switches WL @@-@@@@@@@@ (1) (2) () (4) () () (7) (8) (9)(10) (1) Electrical Rating Blank Standard load 01 Microload Note: Dimensions are the same as the standard models. () Environment-resistant Model Specifications Blank Standard RP Corrosion-proof *1 P1 Weather-proof *1 Note: Dimensions are the same as the standard models. *1. Refer to page 4 for applicable models. (4) Built-in Switch Type Blank Standard Hermetically sealed *1 Note: Dimensions are the same as the standard models. *1. Refer to page 4 for applicable models. () Temperature Specifications Blank Standard: 10 C to +80 C TH Heat-resistant: + C to +120 C *1 TC Low-temperature: 40 C to +40 C *1 Note: Dimensions are the same as the standard models. *1. Refer to page 4 for applicable models. (7) Conduit Size, Ground Terminal Specifications *2 Blank G1/2 without ground terminal G1 G1/2 with ground terminal G Pg1. with ground terminal Y M20 with ground terminal TS 1/2-14NPT with ground terminal Note: Dimensions are the same as the standard models. *2. Models with ground terminals are approved by EN/IEC (CE marking). () Hermetic Model Specifications (2) and Head Specifications Symbol type Switch without lever CA2 Roller lever: Standard model R8 WLRCA2 CA2-7 Roller lever: Standard model R0 WLRCA2 CA2-8 Roller lever: Standard model R WLRCA2 H2 Roller lever: General-purpose overtravel model, 80 WLRH2 G2 Roller lever: High-sensitivity overtravel, 80 WLRG2 CA2-2 Roller lever:, 90 WLRCA2-2 CA2-2N Roller lever:, 90 WLRCA2-2N GCA2 Roller lever: High-precision R8 WLRGCA2 CA12 Adjustable roller lever: Standard WLRCA2 H12 Adjustable roller lever: General-purpose overtravel model, 80 WLRH2 G12 Adjustable roller lever: High-sensitivity overtravel, 80 WLRG2 CA12-2 Adjustable roller lever:, 90 WLRCA2-2 CA12-2N Adjustable roller lever:, 90 WLRCA2-2N CL Adjustable rod lever: Standard, 2 to 140 mm WLRCL HL Adjustable rod lever: General-purpose overtravel model, 80, 2 to 140 mm WLRH2 HAL4 Adjustable rod lever: General-purpose overtravel model, 80, 0 to 80 mm WLRH2 GL Adjustable rod lever: High-sensitivity overtravel, 80, 2 to 140 mm WLRG2 CL-2 Adjustable rod lever:, 90, 2 to 140 mm WLRCA2-2 CL-2N Adjustable rod lever:, 90, 2 to 140 mm WLRCA2-2N HAL Rod spring lever: General-purpose overtravel model, 80 WLRH2 CA2-41 Fork lever lock: Maintained, WL-A100 WLRCA2 CA2-42 Fork lever lock: Maintained, WL-A102 WLRCA2 CA2-4 Fork lever lock: Maintained, WL-A104 WLRCA2 D Plunger: Top plunger D2 Plunger: Top-roller plunger D28 Plunger: Sealed top-roller plunger D Plunger: Top-ball plunger SD Plunger: Horizontal plunger SD2 Plunger: Horizontal-roller plunger SD Plunger: Horizontal-ball plunger NJ Flexible rod: Coil spring NJ-0 Flexible rod: Coil spring, multi-wire NJ-2 Flexible rod: Coil spring, resin rod NJ-S2 Flexible rod: Steel wire (8) Indicator Type Blank No cables or molding General-purpose built-in switch with cables attached and molded conduit opening and cover (cover cannot be removed). * 19 Airtight built-in switch with cables attached and molded conduit opening, cover, and box interior cover screws (cover cannot be removed). * 140 Airtight built-in switch with cables attached and molded conduit opening, cover, head, box interior, cover screws, and 141 head screws (cover cannot be removed, Head direction cannot be changed). The Head opening is created to protect it from cutting powder. * Airtight built-in switch with cables attached and molded conduit opening, cover, box interior, and cover screws (cover cannot be 14 removed, Head can be mounted in any of 4 directions). The Head opening is created to protect it from cutting powder. * Airtight built-in switch with cables attached and molded cover and box interior (cover cannot be removed, Head direction can be RP40 changed). SC Connector can be removed, so it is possible to use flexible conduits for the cable. * Airtight built-in switch with cables attached, fluorine rubber used, RP0 and molded conduit opening, cover, and box interior (cover cannot be removed, Head direction cannot be changed). * * Refer to page 4 for applicable models. Symbol Element Voltage Leakage current Blank No indicator LE Neon lamp 12 to 20 VAC Approx. 0. to 1.9 ma LD LED 11 VAC/VDC Approx. 0. ma 10 to 24 VAC/VDC Approx. 0.4 ma Note: Dimensions are the same for both LE and LD models. (9) Indicator Wiring 2 NC connection: Light-ON when operating NO connection: Light-ON when not operating Note: Include the indicator wiring specification only when a () hermetic seal and (8) operation indicator have been selected. (10) Lever Type Blank A Standard lever Double nut lever 9

General-purpose Switches Direct-wired Connector Pre-wired Connector Sensor I/O Connector Switches WL @@-@ LD @ (1) (2) () (4) () (1) Electrical Rating Blank Standard load 01 Microload Note: Dimensions are the same as the standard models. (2) Type (4) Indicator Type LD LED, 10 to 11 VAC/DC () Wiring Specifications CA2 GCA2 H2 G2 D2 D28 Roller lever: Standard model Roller lever: High-precision model Roller lever: General-purpose overtravel model Roller-lever: High-sensitivity overtravel model Top-roller plunger Sealed top-roller plunger () Built-in Switch Type Blank Standard Hermetically sealed Note: Dimensions are the same as the standard models. Spatter-prevention Switches WL @@-@@S @ (1)(2) ()(4) () (1) Electrical Rating K1A Direct-wired Connector (2-conductor: AC, NO wiring, connector pins No., 4) K1 Direct-wired Connector (2-conductor: DC, NO wiring, connector pins No., 4) K4A Direct-wired Connector (4-conductor: AC) K4 Direct-wired Connector (4-conductor: DC) -M1J * Pre-wired Connector *2 (2-conductor: DC, NO wiring, connector pins No., 4) -M1GJ *1 Pre-wired Connector *2 (2-conductor: DC, NO wiring, connector pins No. 1, 4) -M1JB Pre-wired Connector *2 (2-conductor: DC, NC wiring, connector pins No., 2) -AGJ0 Pre-wired Connector *2 (4-conductor, AC) -DGJ0 *1 Pre-wired Connector *2 (4-conductor, DC) -DK1EJ0 *1 Pre-wired Connector *2 (-conductor: DC, NO wiring, connector pins No. 2,, 4) *1. Models with pre-wired connectors and DC specifications have EN/IEC approval (CE marking). *2. With 0.-m cable attached. WLM@ -LD @ (1) (2) () (1) Long-life Switches Blank Standard load 01 Microload Note: Dimensions are the same as the standard models. (2) Type CA2 GCA2 H2 G2 D28 () Built-in Switch Type Note: Dimensions are the same as the standard models. (4) Indicator Type Roller lever: Standard model Roller lever: High-precision model Roller lever: General-purpose model Roller lever: High-sensitivity model Sealed top-roller plunger Blank Standard Hermetically sealed LD LE LED, AC/DC Neon lamp Note: Dimensions are the same for both LE and LD models. CA2 GCA2 H2 G2 (2) Indicator Type LD Roller lever: Standard model Roller lever: High-precision model Roller lever: General-purpose overtravel model Roller lever: High-sensitivity overtravel model () Wiring Specifications * With 0.-m cable attached. LED, 10 to 11 VAC/DC Blank Screw terminal: G1/2 conduit K1A Direct-wired Connector: 2-conductor, AC K1 Direct-wired Connector: 2-conductor, DC K4A Direct-wired Connector: 4-conductor, AC K4 Direct-wired Connector: 4-conductor, DC -M1J Pre-wired Connector: 2-conductor, DC * -AGJ0 Pre-wired Connector: 4-conductor, AC * -DGJ0 Pre-wired Connector: 4-conductor, DC * () Wiring Specifications Blank Screw terminal: G1/2 conduit -M1J-1 *1 Pre-wired Connector *2 (2-conductor: DC, NO wiring, connector pins No., 4) -M1GJ-1 *1 Pre-wired Connector *2 (2-conductor: DC, NO wiring, connector pins No. 1, 4) -DGJS0 *1 Pre-wired Connector *2 (4-conductor: DC) *1. Models with pre-wired connectors and DC specifications are approved by EN/IEC (CE marking) except for LE Models (Neon Lamp Models). *2. With 0.-m cable attached. 10

Ordering Information WL/WLM General-purpose Switches Standard Switches Note: Models are also available with ground terminals. Lever Roller lever R8 Roller lever R0 Roller lever R Item Model Model Model Standard load WLCA2 WLCA2-7 WLCA2-8 Basic Microload WL01CA2 WL01CA2-7 WL01CA2-8 High-precision Plunger 90 operation Standard load WLH2 Microload WL01H2 Standard load WLG2 Microload WL01G2 Standard load WLCA2-2 Microload WL01CA2-2 Standard load WLCA2-2N Microload WL01CA2-2N Standard load WLGCA2 Microload WL01GCA2 Adjustable roller lever Adjustable rod lever 2 to 140mm Adjustable rod lever 0 to 80mm Rod spring lever Item Model Model Model Model Standard load WLCA12 WLCL Basic Microload WL01CA12 WL01CL Generalpurpose Highsensitivity Generalpurpose Highsensitivity 90 operation Standard load WLH12 WLHL WLHAL4 WLHAL Microload WL01H12 WL01HL Standard load WLG12 WLGL Microload WL01G12 WL01GL Standard load WLCA12-2 WLCL-2 Microload WL01CA12-2 Standard load WLCA12-2N WLCL-2N Microload WL01CA12-2N WL01CL-2N Fork lever lock (with WL-A100 plastic roller lever) Fork lever lock (with WL-A102 plastic roller lever) Fork lever lock (with WL-A104 plastic roller lever) Fork lever lock (with WL-A104 plastic roller lever) Item Model Model Model Model Standard load WLCA2-41 WLCA2-42 WLCA2-4 WLCA2-44 Maintained Microload WL01CA2-41 WL01CA2-4 WL01CA2-44 Top plunger Top-roller plunger Top-ball plunger Sealed top-roller plunger Item Model Model Model Model Standard load WLD WLD2 WLD WLD28 Top plunger Microload WL01D WL01D2 WL01D WL01D28 Flexible Rod Horizontal plunger Horizontal-roller plunger Horizontal-ball plunger Item Model Model Model Standard load WLSD WLSD2 WLSD Side plunger Microload WL01SD WL01SD2 WL01SD Coil spring (spring diameter:.) Coil spring (spring diameter: 4.8) Coil spring (resin rod diameter: 8) Steel wire (wire diameter: 1) Item Model Model Model Model Standard load WLNJ WLNJ-0 WLNJ-2 WLNJ-S2 Flexible rod Microload WL01NJ WL01NJ-0 WL01NJ-2 WL01NJ-S2 11

General-purpose Switches Indicator-equipped Switches Lever Plunger Roller lever R8 Roller lever R0 Roller lever R Adjustable roller lever Item Model Model Model Model Neon lamp WLCA2-LE WLCA2-7LE WLCA2-8LE WLCA12-LE Basic LED WLCA2-LD WLCA2-7LD WLCA2-8LD WLCA12-LD High-precision 90 operation Neon lamp WLH2-LE WLH12-LE LED WLH2-LD WLH12-LD Neon lamp WLG2-LE WLG12-LE LED WLG2-LD WLG12-LD Neon lamp WLCA2-2LE WLCA12-2LE LED WLCA2-2LD WLCA12-2LD Neon lamp WLCA2-2NLE WLCA12-2NLE LED WLCA2-2NLD WLCA12-2NLD Neon lamp WLGCA2-LE LED WLGCA2-LD Adjustable rod lever 2 to 140 mm Adjustable rod lever 0 to 80 mm Rod spring lever Item Model Model Model Neon lamp WLCL-LE Basic LED WLCL-LD Generalpurpose Highsensitivity Generalpurpose Highsensitivity 90 operation Neon lamp WLHL-LE WLHAL4-LE WLHAL-LE LED WLHL-LD WLHAL4-LD WLHAL-LD Neon lamp WLGL-LE LED WLGL-LD Neon lamp WLCL-2LE LED WLCL-2LD Neon lamp WLCL-2NLE LED WLCL-2NLD Fork lever lock (with WL-A100 Plastic Roller Lever) Fork lever lock (with WL-A102 Plastic Roller Lever) Fork lever lock (with WL-A104 Plastic Roller Lever) Item Model Model Model Maintained Neon lamp WLCA2-41LE WLCA2-42LE WLCA2-4LE LED WLCA2-41LD WLCA2-4LD Top plunger Top-roller plunger Top-ball plunger Sealed top-roller plunger Item Model Model Model Model Neon lamp WLD-LE WLD2-LE WLD-LE WLD28-LE Top plunger LED WLD-LD WLD2-LD WLD-LD WLD28-LD Flexible Rod Horizontal plunger Horizontal-roller plunger Horizontal-ball plunger Item Model Model Model Neon lamp WLSD-LE WLSD2-LE WLSD-LE Side plunger LED WLSD-LD WLSD2-LD WLSD-LD Coil spring (spring diameter:.) Coil spring (spring diameter: 4.8) Coil spring (resin rod diameter: 8) Steel wire (wire diameter: 1) Item Model Model Model Model Neon lamp WLNJ-LE WLNJ-0LE WLNJ-2LE WLNJ-S2LE Flexible rod LED WLNJ-LD WLNJ-0LD WLNJ-2LD WLNJ-S2LD 12

General-purpose Switches Sensor I/O Connector Switches Direct-wired Connectors Item Basic General-purpose High-sensitivity High-precision Wiring Built-in switch specification Model Model Model Model Roller lever 2-conductor DC NO connector pins No., 4 Standard WLCA2-LDK1 WLH2-LDK1 WLG2-LDK1 WLGCA2-LDK1 Airtight seal WLCA2-LDK1 WLH2-LDK1 WLG2-LDK1 WLGCA2-LDK1 4-conductor DC Standard WLCA2-LDK4 WLH2-LDK4 WLG2-LDK4 WLGCA2-LDK4 Airtight seal WLCA2-LDK4 WLH2-LDK4 WLG2-LDK4 WLGCA2-LDK4 Top-roller plunger 2-conductor DC NO connector pins No., 4 Standard WLD2-LDK1 Airtight seal WLD2-LDK1 4-conductor DC Standard WLD2-LDK4 Airtight seal WLD2-LDK4 Pre-wired Connectors Item Basic General-purpose High-sensitivity High-precision Wiring Built-in switch specification Model Model Model Model Roller lever 2-conductor DC NO NC connector pins No., 4 connector pins No. 1, 4 connector pins No., 2 Standard WLCA2-LD-M1J WLH2-LD-M1J WLG2-LD-M1J WLGCA2-LD-M1J Airtight seal WLCA2-LD-M1J WLGCA2-LD-M1J Standard WLCA2-LD-M1GJ WLH2-LD-M1GJ WLG2-LD-M1GJ WLGCA2-LD-M1GJ Airtight seal WLCA2-LD-M1GJ WLG2-LD-M1GJ Standard WLG2-LD-M1JB Airtight seal WLCA2-LD-M1JB WLG2-LD-M1JB WLGCA2-LD-M1JB 4-conductor DC Standard WLCA2-LD-DGJ0 WLH2-LD-DGJ0 WLG2-LD-DGJ0 Airtight seal WLCA2-LD-DGJ0 WLG2-LD-DGJ0 WLGCA2-LD-DGJ0 -conductor DC connector pins No. 2,, 4 Standard WLCA2-LD-DK1EJ0 WLG2-LD-DK1EJ0 Airtight seal WLCA2-LD-DK1EJ0 WLG2-LD-DK1EJ0 Top-roller plunger 2-conductor DC NO NC connector pins No., 4 connector pins No. 1, 4 connector pins No., 2 Standard WLD2-LD-M1J Airtight seal WLD2-LD-M1J Standard WLD2-LD-M1GJ Airtight seal WLD2-LD-M1GJ Standard Airtight seal WLD2-LD-M1JB 4-conductor DC Standard WLD2-LD-DGJ0 Airtight seal -conductor DC connector pins No. 2,, 4 Standard WLD2-LD-DK1EJ0 Airtight seal WLD2-LD-DK1EJ0 1

Environment-resistant Switches Note: Models are also available with ground terminals. Roller lever R8 Item Airtight seal Hermetic seal Molded terminals Anti-coolant -19-140 -141 Basic General-purpose High-sensitivity Model Model Model No indicator WLCA2- WLH2- WLG2- Indicator LED WLCA2-LD WLH2-LD WLG2-LD Neon WLCA2-LE WLH2-LE WLG2-LE No indicator WLCA2-19 WLH2-19 WLG2-19 Indicator NC wiring WLCA2-19LD2 NO wiring WLCA2-19LD WLG2-19LD No indicator WLCA2-140 WLH2-140 WLG2-140 Indicator NC wiring WLCA2-140LD2 WLG2-140LD2 NO wiring WLCA2-140LD WLG2-140LD No indicator WLCA2-141 WLH2-141 WLG2-141 Indicator NC wiring WLCA2-141LD2 WLG2-141LD2 NO wiring WLCA2-141LD WLH2-141LD WLG2-141LD No indicator WLCA2-RP0 WLH2-RP0 WLG2-RP0 Indicator NC wiring WLCA2-RP0LD2 WLG2-RP0LD2 NO wiring WLCA2-RP0LD WLH2-RP0LD WLG2-RP0LD WLCA2-TH WLH2-TH WLG2-TH Heat-resistant Low-temperature WLCA2-TC WLH2-TC WLG2-TC No indicator Corrosion-proof WLCA2-RP WLH2-RP WLG2-RP Weather-proof WLCA2-P1 WLH2-P1 WLG2-P1 Roller lever R8 90 (-2 model) 90 (-2N model) High-sensitivity Item Model Model Model No indicator WLCA2-2 WLCA2-2N WLGCA2- Airtight seal LED WLCA2-2LD WLCA2-2NLD WLGCA2-LD Indicator Neon WLCA2-2LE WLCA2-2NLE WLGCA2-LE No indicator WLCA2-219 WLCA2-2N19 WLGCA2-19 -19 NC wiring WLCA2-219LD2 WLGCA2-19LD2 Indicator NO wiring WLCA2-219LD WLGCA2-19LD No indicator WLCA2-2N140 WLGCA2-140 Molded -140 NC wiring WLGCA2-140LD2 terminals Indicator Hermetic NO wiring WLGCA2-140LD seal No indicator WLGCA2-141 -141 NC wiring Indicator NO wiring WLGCA2-141LD No indicator WLCA2-2RP0 WLGCA2-RP0 Anti-coolant NC wiring WLCA2-2RP0LD2 WLGCA2-RP0LD2 Indicator NO wiring WLCA2-2RP0LD WLGCA2-RP0LD Heat-resistant WLCA2-2TH WLCA2-2NTH WLGCA2-TH Low-temperature No indicator WLCA2-2TC WLCA2-2NTC WLGCA2-TC Corrosion-proof WLGCA2-RP 14

Adjustable roller lever Item Airtight seal Hermetic seal Molded terminals Basic General-purpose High-sensitivity Model Model Model No indicator WLCA12- Indicator LED WLCA12-LD Neon WLCA12-LE -19 WLCA12-19 -140 WLCA12-140 -141 No indicator WLCA12-141 Anti-coolant WLCA12-RP0 Heat-resistant WLCA12-TH WLH12-TH WLG12-TH Low-temperature WLCA12-TC WLH12-TC WLG12-TC No indicator Corrosion-proof WLCA12-RP WLH12-RP WLG12-RP Weather-proof WLCA12-P1 WLH12-P1 WLG12-P1 Adjustable roller lever 90 (-2 model) 90 (-2N model) Item Model Model Heat-resistant WLCA12-2TH WLCA12-2NTH No indicator Low-temperature WLCA12-2TC WLCA12-2NTC Adjustable rod lever 2 to 140 mm Item Airtight seal Hermetic seal Molded terminals Basic General-purpose High-sensitivity Model Model Model No indicator WLCL- Indicator LED WLCL-LD Neon -19 WLCL-19-140 WLCL-140-141 No indicator Anti-coolant WLCL-RP0 Heat-resistant WLCL-TH WLHL-TH WLGL-TH Low-temperature WLCL-TC WLHL-TC WLGL-TC No indicator Corrosion-proof WLCL-RP WLHL-RP WLGL-RP Weather-proof WLCL-P1 WLHL-P1 WLGL-P1 Adjustable rod lever 2 to 140 mm 90 (-2 model) 90 (-2N model) Item Model Model Heat-resistant WLCL-2TH WLCL-2NTH Low-temperature No indicator WLCL-2TC WLCL-2NTC Corrosion-proof WLCL-2RP 1

Top-roller plunger Sealed top-roller plunger Horizontal plunger Item Model Model Model No indicator WLD2- WLD28- WLSD- Airtight seal LED WLD2-LD WLD28-LD WLSD-LD Indicator Neon WLD2-LE WLD28-LE Molded -19 WLD2-19 WLD28-19 WLSD-19 Hermetic terminals No indicator seal -140 WLD28-140 Anti-coolant WLD2-RP0 WLD28-RP0 WLSD-RP0 Heat-resistant WLD2-TH WLD28-TH WLSD-TH Low-temperature No indicator WLD2-TC WLSD-TC Corrosion-proof WLD2-RP WLD28-RP WLSD-RP Note: The standard cable length for models with airtight seals is m. Horizontal-roller plunger Coil spring (spring diameter:.) Coil spring (resin rod diameter: 8) Item Model Model Model No indicator WLSD2- WLNJ- WLNJ-2 Airtight seal LED WLSD2-LD WLNJ-LD WLNJ-2LD Indicator Neon Molded -19 WLSD2-19 WLNJ-19 Hermetic terminals No indicator seal -140 WLSD2-140 WLNJ-140 WLNJ-2140 Anti-coolant WLSD2-RP0 WLNJ-RP0 WLNJ-2RP0 Heat-resistant WLSD2-TH WLNJ-TH Low-temperature No indicator WLSD2-TC WLNJ-TC WLNJ-2TC Corrosion-proof WLSD2-RP WLNJ-RP WLNJ-2RP Note: The standard cable length for models with airtight seals is m. 1

Spatter-prevention Switches Roller lever Sealed top-roller plunger Double nut lever lever Item Neon lamp operation indicator LED operation indicator Model Model Model Basic WLCA2-LEAS WLCA2-LES WLD28-LES General-purpose WLH2-LEAS WLH2-LES High-sensitivity WLG2-LEAS WLG2-LES High-precision WLGCA2-LES Basic WLCA2-LDAS WLCA2-LDS WLD28-LDS General-purpose WLH2-LDAS WLH2-LDS High-sensitivity WLG2-LDAS WLG2-LDS High-precision WLGCA2-LDS Note: Ask your OMRON representative about WL01@-@S Microload Switches. Long-life Switches Item LED operation indicator *1 Basic High-precision General-purpose High-sensitivity Model Model Model Model Roller lever, screw terminal WLMCA2-LD WLMH2-LD WLMG2-LD WLMGCA2-LD Roller lever, direct-wired connector 2-conductor 4-conductor AC WLMCA2-LDK1A WLMH2-LDK1A WLMG2-LDK1A WLMGCA2-LDK1A DC WLMCA2-LDK1 WLMH2-LDK1 WLMG2-LDK1 WLMGCA2-LDK1 AC WLMCA2-LDK4A WLMH2-LDK4A WLMG2-LDK4A WLMGCA2-LDK4A DC WLMCA2-LDK4 WLMH2-LDK4 WLMG2-LDK4 WLMGCA2-LDK4 Roller lever, pre-wired connector *2 2-conductor DC WLMCA2-LD-M1J WLMH2-LD-M1J WLMG2-LD-M1J WLMGCA2-LD-M1J 4-conductor DC WLMCA2-LD-DGJ0 WLMH2-LD-DGJ0 WLMG2-LD-DGJ0 *1. The default setting is light-on when not operating. Turn the lamp holder by 180 to change the setting to light-on when operating. (Ask your OMRON representative about 2-conductor models.) *2. With 0.-m cable attached. 17

Individual Parts Heads type Set model Head model (with ) WLCA2 WL-1H1100 WLG2 WL-2H1100 Roller lever WLH2 WL-2H1100-1 * WLCA2-2 WL-H1100 WLCA2-2N WL-H1100 WLCA12 WL-1H2100 WLG12 WL-2H2100 Adjustable WLH12 WL-2H2100-1 * roller lever WLCA12-2 WL-H2100 WLCA12-2N WL-H2100 WLCL WL-4H4100 Adjustable WLGL WL-2H4100 rod lever WLCL-2 WL-H4100 WLCL-2N WL-H4100 * The model number of Heads without levers are same as those of Heads with levers without the numbers at the end. Example: WL-1H1100 becomes WL-1H without the lever. However, the WLH2 and WLH12 become WL-2H-1 and the WLGCA2 becomes WL-1H-1 for the Heads without levers. Other Heads are also available. Ask your OMRON representative. Switches without levers type Set model Head model (with ) WLD WL-7H100 Top plunger WLD2 WL-7H200 WLD WL-7H00 WLD28 WL-7H400 WLSD WL-8H100 Horizontal WLSD2 WL-8H200 plunger WLSD WL-8H00 WLCA2-41 WL-H100 Fork lever WLCA2-42 WL-H102 lock WLCA2-4 WL-H104 WLCA2-44 WL-H104 WLNJ WL-9H100 Coil spring WLNJ-0 WL-9H200 WLNJ-2 WL-9H00 WLNJ-S2 WL-9H400 Switches for roller levers Switches for adjustable roller levers Switches for adjustable rod lever type Basic R8 High-precision R8 High-sensitivity overtravel, 80 General-purpose overtravel, 80, 90 operation, 90 operation Basic High-sensitivity overtravel, 80 General-purpose overtravel, 80, 90 operation, 90 operation Basic, 2 to 140 mm High-sensitivity overtravel, 80, 2 to 140 mm, 90 operation, 2 to 140 mm, 90 operation, 2 to 140 mm WLRCA2 WLRGCA2 WLRG2 WLRH2 WLRCA2-2 WLRCA2-2N WLRCA2 WLRG2 WLRH2 WLRCA2-2 WLRCA2-2N WLRCL WLRG2 WLRCA2-2 WLRCA2-2N Switches without levers Model Switches for top plungers Switches for horizontal plungers Switches for fork lever locks Maintained, WL-A100 Maintained, WL-A102 Maintained, WL-A104 WLRCA2 Switches for coil springs Covers with Operation Indicators Cover Cover only with indicator Item Neon lamp LED WL-LE WL-LD Model Note: The default setting is "light-on when not operating." Turn the lamp holder by 180 to change the setting to "light-on when operating." 18

Spatter-prevention Products Head (with actuator) Lever Cover with indicator Switches without Levers Complete Heads with allen-head levers Double Nut Lever Lever Double Nut Lever WL Head Replacement Heads can be replaced within the same model group. They cannot be replaced between different model groups. Group No. Set model number Head model number (with ) WLCA2 WL-1H1100 1 WLCA2-7 WL-1H1200 WLCA2-8 WL-1H100 WLCA12 WL-1H2100 2 WLCL WL-4H4100 * WLH2 WL-2H1100-1 WLH12 WL-2H2100-1 WLHL WL-2H4100 WLHAL4 WL-2H410 WLHAL WL-2H4107 WLCA2-2N WL-H1100 4 WLCA12-2N WL-H2100 WLCL-2N WL-H4100 WLCA2-2 WL-H1100 WLCA12-2 WL-H2100 WLCL-2 WL-H4100 WLG2 WL-2H1100 WLG12 WL-2H2100 WLGL WL-2H4100 WLCA2-41 WL-H100 7 WLCA2-42 WL-H102 WLCA2-4 WL-H104 WLCA2-44 WL-H104 WLD WL-7H100 8 WLD2 WL-7H200 WLD WL-7H00 9 WLD28 WL-7H400 * WLSD WL-8H100 10 WLSD2 WL-8H200 WLSD WL-8H00 11 WLNJ WL-9H100 WLNJ-0 WL-9H200 12 WLNJ-2 WL-9H00 * 1 WLNJ-S2 WL-9H400 * * This Heads are special and must be used. Do not use any other Head. Cover with Indicator Switches without levers Model Model Model Model Model Model WL-1H1100S (for WLCA2-@ or WLGCA2-@) WL-2H1100S (for WLH2-@ or WLG2-@) WL-1A10S Roller lever WL-1A10S Roller Lever Neon lamp WL-LES LED (LED) WL-LDS WLRCA2-LDS WLRH2-LES WLRH2-LDS WLRG2-LDS WLRGCA2-LES Specifications Approved Standards Agency Standard File No. Approved models UL UL08 E77 CSA CSA C22.2 No.14 LR474 J0022, TÜV Rheinland EN0947--1 J99002, Contact your OMRON representative for information on approved models. J99099 CCC (CQC) GB14048. 200401001287 19

General-purpose/Weather-proof Switches Ratings Standard-load Switches Item Rated voltage (V) Non-inductive load (A) Resistive load Lamp load Inductive load (A) Inductive load Motor load Model NC NO NC NO NC NO NC NO Basic models, overtravel models (except for highsensitivity models), and high-precision models High-sensitivity overtravel models Inrush current NC NO * For high-sensitivity overtravel models. 12 VAC 20 VAC 00 VAC 8 VDC 14 VDC 0 VDC 12 VDC 20 VDC 12 VAC 20 VAC 12 VDC 20 VDC 0 A max. (1 A max. *) 20 A max. (10 A max. *) 10 10 10 10 10 0.8 0.4 0.4 0.2 2 1. 4 0.2 0.1 1. 1 0.8 0.2 0.1 10 10 10 10 0.8 0.4 1. 4 0.2 0.1 2. 1. 0.8 Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).. A lamp load has an inrush current of 10 times the steady-state current. 4. A motor load has an inrush current of times the steady-state current.. For PC loads, use the microload models. Microload Switches (Refer to these ratings before using the product.) Rated voltage (V) Rated current (A) - Resistive load AC 12 DC 0 0.1 Operation in the following ranges will produce optimum performance. Recommended load range to 0 VDC 0. to 100 ma Voltage (VDC) 0 10 mw 0.8 W 1 0.1 0.1 1 10 100 Current (ma) Minimum applicable load VDC 10 ma Recommended load range VDC 1 ma Approved Standard Ratings UL/CSA Standard-load Switches: A00, NEMA Rated voltage 120 VAC 240 VAC 480 VAC 00 VAC Carry current 10 A Microload Switches 0.1 A 12 VAC, 0.1 A 0 VDC Current (A) TÜV (EN0947--1) (Only models with ground terminals are approved.) WL@ Model WL01@ Note: As an example, AC-1: 2 A/20 V means the following: Volt-amperes (VA) Make Break Make Break 0 0 1 12 Application category and ratings AC-1: 2 A/20 V DC-12: 2 A/48 V AC-14: 0.1 A/12V DC-12: 0.1 A/48 V 1. 1.2 Thermal current (Ithe) 7,200 720 Indicator 10 A 0. A WL@-LE AC-1: 2 A/20 V 10 A Neon lamp WL01@-LE AC-14: 0.1 A/12 V 0. A Neon lamp WL@-LD AC-1: 2 A/11 V DC-12: 2 A/48 V 10 A LED WL01@-LD AC-14: 0.1 A/11 V DC-12: 0.1 A/48 V 0. A LED Application category Rated operating current (Ie) Rated operating voltage (Ue) AC-1 2A 20V Indicator-equipped Switches Model Item Max. rated voltage (V) Leakage current (ma) Neon 12 AC Approx. 0. WL-LE lamp 20 AC Approx. 1.9 11 AC/DC Approx. 0. WL-LD LED 10 to 24 AC/DC Approx. 0.4 Characteristics Degree of protection IP7 Durability Mechanical 1,000,000 operations min. *2 *1 Electrical 70,000 operations min. * Operating speed 1 mm/s to 1 m/s (in case of WLCA2) Operating Mechanical 120 operations/minute min. frequency Electrical 0 operations/minute min. Rated frequency 0/0 Hz Insulation resistance 100 MΩ min. (at 00 VDC) Contact resistance 2 mω max. (initial value for the built-in switch when tested alone) * Dielectric strength Between terminals of the same polarity Between currentcarrying metal part and ground Between each terminal and non-currentcarrying metal part 1,000 VAC (00 VAC), 0/0 Hz for 1min 2,200 VAC (1,00 VAC), 0/0 Hz for 1 min/uimp 2. kv 2,200 VAC (1,00 VAC), 0/0 Hz for 1 min/uimp 2. kv Rated insulation voltage (Ui) 20 V (EN0947--1) Pollution degree (operating environment) (EN0947--1) Short-circuit protective device (SCPD) 10 A, fuse type gg or gi (IEC029) Conditional short-circuit current 100 A (EN0947--1) Conventional enclosed thermal current (Ithe) 10 A, 0. A (EN0947--1) Protection against electric shock Class I Vibration resistance Malfunction 10 to Hz, 1.-mm double amplitude *4 Shock Destruction 1,000 m/s 2 min. resistance Malfunction 00 m/s 2 min. *4 Ambient operating temperature 10 C to +80 C (with no icing) * Ambient operating humidity % to 9% RH Weight Approx. 27 g (in case of WLCA2) Note: 1. The above figures are initial values. 2. The figures in parentheses for dielectric strength are those for the highsensitivity overtravel models. *1. The values are calculated at an operating temperature of + C to + C and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments. *2. Durability is 10,000,000 operations min. for general-purpose or highsensitivity overtravel models, and for flexible rod models. 00,000 operations min. for weather-proof models. *. Durability is 00,000 operations min. for high-sensitivity models. All microload models are 1,000,000 operations min. 00,000 operations min. for weather-proof models. *4. Except flexible rod models. The shock resistance (malfunction) for microload models is 200 m/s 2 min. *. For low-temperature models this is 40 C to +40 C (with no icing). For heatresistant models the range is + C to +120 C. *. For microload models, the contact resistance is 0 mω max. (initial value for built-in switch). 20

Spatter-prevention Switches Ratings Screw terminals Item Rated voltage (V) Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).. A lamp load has an inrush current of 10 times the steady-state current. 4. A motor load has an inrush current of times the steady-state current. Approved Standard Ratings UL/CSA LE Switches (Neon lamp): A00 LD Switches (LED) CCC (GB14048.) Non-inductive load (A) Resistive load Lamp load Note: As an example, AC-1: 2 A/20 V means the following: Inductive load (A) Inductive load Motor load Model NC NO NC NO NC NO NC NO WL@-LES WL@-LDS 12 VAC 20 VAC 10 10 2 1. 1 10 10 2. 1. 11 VAC 10 1. 10 2. 12 VDC 24 VDC 48 VDC Inrush NC current NO Operating temperature Operating humidity Rated voltage 120 VAC 240 VAC WL@ Carry current 10 A 10 4 2 1. 10 0 A max. 20 A max. 10 C to +80 C (with no icing) % to 9%RH max. 4 2 Current (A) Volt-amperes (VA) Make Break Make Break 0 0 Rated voltage Carry current 11 VAC 10 A 11 VDC 0.8 A WL01@ WL@-LE WL01@-LE WL@-LD WL01@-LD Model Application category AC-1 Rated operating current (Ie) 2 A Rated operating voltage (Ue) 20 V 7,200 720 Application category and ratings AC-1: 2 A/20 V DC-12: 2 A/48 V AC-14: 0.1 A/12V DC-12: 0.1 A/48 V AC-1: 2 A/20 V AC-14: 0.1 A/12 V AC-1: 2 A/11 V DC-12: 2 A/48 V AC-14: 0.1 A/11 V DC-12: 0.1 A/48 V Characteristics Degree of protection IP7 Durability Mechanical 1,000,000 operations min. *2 *1 Electrical 70,000 operations min. * Operating speed 1 mm/s to 1 m/s (in case of WLCA2) Operating Mechanical 120 operations/minute min. frequency Electrical 0 operations/minute min. Rated frequency 0/0 Hz Insulation resistance 100 MΩ min. (at 00 VDC) Contact resistance 2 mω max. (initial value for the builtin switch when tested alone) Dielectric strength Between terminals of the same polarity Between currentcarrying metal part and ground Between each terminal and non-currentcarrying metal part 1,000 VAC (00 VAC), 0/0 Hz for 1min 2,200 VAC (1,00 VAC), 0/0 Hz for 1 min/uimp 2. kv 2,200 VAC (1,00 VAC), 0/0 Hz for 1 min/uimp 2. kv Rated insulation voltage (Ui) 20 V (EN0947--1) Pollution degree (operating environment) (EN0947--1) Short-circuit protective device (SCPD) 10 A, fuse type gg or gi (IEC029) Conditional short-circuit current 100 A (EN0947--1) Conventional enclosed thermal current (Ithe) 10 A, 0. A (EN0947--1) Protection against electric shock Class I Vibration resistance Malfunction 10 to Hz, 1.-mm double amplitude Shock Destruction 1,000 m/s 2 min. resistance Malfunction 00 m/s 2 min. Ambient operating temperature 10 C to +80 C (with no icing) Ambient operating humidity % to 9%RH Weight Approx. 27 g (in case of WLCA2) Note: 1. The above figures are initial values. 2. The figures in parentheses for dielectric strength are those for the highsensitivity overtravel models. *1. The values are calculated at an operating temperature of + C to + C and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments. *2. Durability is 10,000,000 operations min. for general-purpose or highsensitivity overtravel models. *. Durability is 00,000 operations min. for high-precision models. All microload models however, are 1,000,000 operations min. 21