Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer

Similar documents
Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer

WARNING! READ BEFORE INSTALLATION

m WARNING! READ m BEFORE INSTALLATION

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

MODEL K WIRE INDICATING PRESSURE TRANSMITTER INTRINSICALLY SAFE VERSION OPERATION AND INSTRUCTION MANUAL

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

EG Series Installation Manual

Miniature I/P, E/P Transducer

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions Output Range Part Number Input psi bar Impedance Output Range

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

Fisher i2p 100 Electro Pneumatic Transducer

V200 Series Positioners

Passive Speed Sensors

Type Type 1001 Transducers. I/P & E/P Transducers

% # ) Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT

Installation Manual OPEN. For Corrosive Service. The ONYX integrates electronic sensors and pneumatic valving into a vapor tight enclosure.

Features. Flexibility

AMETEK MODEL 88 SERIES ELECTRONIC PRESSURE TRANSMITTER

EZ-LIGHT K30L and K50L Intrinsically Safe Indicators

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro Pneumatic Transducer

Ex Instruction manual. Rotamass Coriolis mass flow meter. IM 01U10X03-00EN-R, 1st edition, Rev FM-1

Fisher 3660 and 3661 Positioners

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

SKINNER Intrinsically Safe Series Four-Way

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

LTX RF LEVEL SENSOR. Instruction Manual

Certificate of Compliance

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Fisher 546 Electro Pneumatic Transducer

Smart Pressure Transmitter

Model PPM 200 Precision Pulse Volumetric Fluid Flow Meter

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

User s Manual. Model MLA & MLD Loop Powered Process Indicators. Model MLD (Digital) Model MLA (Analog)

U.S. GAUGE PMT PRODUCTS 820 PENNSYLVANIA BLVD., FEASTERVILLE, PENNSYLVANIA U.S.A. TEL: (215) FAX: (215)

PXT-K Series. Pressure Transmitters Section 05

Optic Level Switch LO10 Series Owner s Manual

Ar-Mite TM Low Flow Armored Flowmeter

1100 Series Piston Type Differential Pressure Gauges

Proximity Transmitters, and Seismic Vibration Transmitters

Carbon Monoxide Transmitter

Industrial Pressure Transmitters

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

NIFW % # ) Air and Inert Gas Non-Incendive Field Wiring Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

WBS 3000 Water Bottom Sensor for fuel oil and chemical storage tanks Installation and Operating Instructions

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

Metal Particle Detector

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Smart Pressure Transmitter

Type Type I/P & E/P Transducers

Model 3400 Intrinsically Safe Load Cell

Certificate of Compliance

Electropneumatic Transducer (I/P, E/P)

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

Creative Engineers Inc. Pittsburgh, PA York, PA Phoenix, MD P.O. Box 206 Phoenix, MD Phone (443)

From lab to production, providing a window into the process

Maximum Line Resistance vs. Length of Wire Max. Loop Resistance. Max. Wire Run 18AWG 7x26 Stranded (ft)

Fisher 3582 and 3582i Positioners, 582i Electro-Pneumatic Converter, and 3583 Valve Stem Position Transmitters

Fisher 3582 and 3582i Positioners, 582i Electro Pneumatic Converter, and 3583 Valve Stem Position Transmitter

Smart Pressure Transmitter

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

Creative Engineers Inc. Pittsburgh, PA York, PA Phoenix, MD P.O. Box 206 Phoenix, MD Phone (443)

P200 P/I Transducer. Installation, Operation, and Maintenance Instructions INTRODUCTION

Certificate of Compliance

OEM Pressure Transmitters

Contents. Pressure measurement technology Pressure calibrators 18 Exercises 19-20

Type I/P & E/P Transducers

SATRON VDt Differential Pressure Transmitter

PT-500 Analog Output Series User Manual

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

Pressure Transmitter. Informational & Installation Manual

Fisher i2p-100 Electro Pneumatic Transducer

CANADA SENSORS TECHNOLOGY INC.

MS Application. Features. Proportional Valve Actuator General Instructions

1' to 10' deep and 1' to 25' deep

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

Proximity Transmitters, and Seismic Vibration Transmitters

LIMIT SWITCH Axiom - AX

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

Intrusive RF Capacitance Level Switch LP10 Series Owner s Manual Provided by:

SIGNET 2760 DryLoc ph/orp Preamplifier

Mountable with O-ring seal Urea level ±0.5% Accuracy Urea pressure ±2.0 Total Error Band Air Brakes Corrosive fluid measurement for E&V applications

SPANS AND RANGES. Lower Range Limits 150 in. H 2 O ( 38 kpa) 800 in. H 2 O ( 200 kpa)

User s Guide EP510, IP510, EP511, IP511 SERIES. Electroneumatic Converters. Shop online at

Model Connections Max. Flow Range (H 2 O) 10A A3220 Horizontal ¼ NPT 100 l/h. 10A3225/55 Vertical ¼ NPT 100 l/h. Vertical 1 NPT Vertical 1 G

G2 Industrial Grade Meters

PPT 802, Proximity Probe Transducer System

InVue Electronic Flowmeter, Model NT4400

Type 2000 Transducer Product Instructions

Fisher 3610J and 3620J Positioners and 3622 Electro Pneumatic Converter

SM-1000 SERIES ROTARY ACTUATORS

Transcription:

CONTROL SYSTEMS 1239 WILLOW LAKE BOULEVARD VADNAIS HEIGHTS, MINNESOTA 55110 651 766 2700 Fax: 651 766 2701 www.control systems.usfilter.com Product Specification A1000i Loop Powered/4-20mA Submersible Level The A1000i is a 9-30VDC, two wire loop powered submersible level transducer with a 4-20mA signal output. It is mounted at a low point in a liquid media. The transducer uses a gauge pressure piezoresistive sensor element to measure the hydrostatic head-pressure. The sensor element is isolated from the media by a Teflon coated Buna-N diaphragm. This pressure is proportional to the height of the liquid above the sensing diaphragm and is converted to a proportional 4-20mA signal. This 4-20mA signal spans the full pressure range of the transducer. The transducer is barometrically compensated via a rigid breather tube connected to a panel mounted sealed breather assembly. All A1000i transducers require a Breather Assembly Kit. Part Number Description Sensors 6012950011 A1000i sensor 1.5 PSI 4-20mA output (0-3.5 ft of water) 6012950012 A1000i sensor 5 PSI 4-20mA output (0-11.5 ft of water) 6012950013 A1000i sensor 15 PSI 4-20mA output (0-34.7 ft of water) 6012950014 A1000i sensor 30 PSI 4-20mA output (0-69.3 ft of water) Housing/Cable Assembly 6012640002 A1000 Housing/Cable Sub-Assembly 20ft 6012640003 A1000 Housing/Cable Sub-Assembly 30ft 6012640004 A1000 Housing/Cable Sub-Assembly 40ft 6012640006 A1000 Housing/Cable Sub-Assembly 60ft 6012640008 A1000 Housing/Cable Sub-Assembly 80ft 6012640010 A1000 Housing/Cable Sub-Assembly 100ft 60126400XX A1000 Housing/Cable Sub-Assembly custom lengths (XX equals number of feet) Mounting Hardware and Accessories 6011340001 B100 9G CLS Stainless Steel Pipe Mounting Clamps 6014180001 Cable Suspension Mounting Pipe (without SS cable) 60144000XX Stainless steel cable; each additional 10 ft (XX) 6012880001 Breather Assembly Kit (required for all A1000i sensors) 6012910002 Terminal Connection (Junction) Box w/built In Breather Assembly Agency Approval FM and CSA Intrinsically Safe Class I, Div. 1, Groups A,B,C,D with an approved barrier.

Specifications Environmental Atmosphere Ventilation Operating Temperature sealed breather system equalizes atmospheric pressure range 32ºF to +158ºF Liquid must remain fluid. Physical Housing 316 cast stainless steel, Teflon coated Cable heavy-duty polyethylene with vent tube, shield and 18 AWG conductors Mounting suspension cable mount or 1 pipe mount Pressure Ranges 1.5 PSI to 30 PSI Max Over Pressure Range 1.5 PSI 8X full scale 5.0 PSI 4X full scale 15 PSI & 30 PSI 2X full scale Exposed Materials 316 cast stainless steel Teflon coated, synthetic rubber and urethane Sensing Head two-layer diaphragm with Teflon and Buna-N material Electrical Power Required 9 30 VDC Typical Loop Resistance 250 ohm @ 15VDC Maximum Loop Resistance 750 ohm @ 24VDC Signal Output 4-20mA Accuracy ±0.25 % full scale with long term stability of 0.2 % full scale per year. Page 2 of 7

Intrinsically Safe Barrier Applications When selecting an intrinsically safe barrier consider the following: cable length, classification of hazardous area, cable inductance and capacitance, and the intrinsic safe ground system. Barriers whose entity parameters meet the following requirements can be used. Voc Vmax Isc Imax Ca > Ci + Ccable La > Li + Lcable A1000i Transmitter Entity Parameters Vmax Imax Ci Li 28V 93mA 0.11 uf 0.22mH Note: USFCS IS1-2 Part number 6013150004 does not meet these entity parameters. An intrinsically safe system should be designed and tested by a qualified engineering professional. Compatible Barriers Manufacturer Part No. Type MAX Loop Resistance MTL 7706 Amplified Zener, 500 ohms Common Neg. MTL 5041 Galvanically Isolated 1000 ohms Phoenix Contact Model PI/Ex-ME-RPS(s)-I/I 2835422 Galvanically Isolated 800 ohms Note: Each of the barriers requires 24VDC to operate. When any of these barriers are used, with a CMR25-04, an external power source is required to power the IS barrier. MTL7706+ Active Zener Barrier (UL Pending) Page 3 of 7

MTL5041 Galvanically Isolated Barrier Phoenix Contact Model PI/Ex-ME-RPS(s)-I/I Galvanically Isolated Barrier Page 4 of 7

D620i CMR25 and IS Barrier Application Note: This application connects the D620I common to ground. Note: Current flows through ground. D620i Application Note: This application is not intrinsically safe. Page 5 of 7

TP12 Transient Protector Application Note: This application is not intrinsically safe Microcat Application Note: This application is not intrinsically safe. Page 6 of 7

Suspension Cable Mounting Page 7 of 7