systems company Operating Manual - Adjustable Lower End Model 0.2% - 2% WSP Model 0.78% - 5% WSP

Similar documents
Agxcel GX12i Chemical Injection System

AGXCEL GX12i CHEMICAL INJECTOR 2% INJECTOR UNIT - PN# % INJECTOR UNIT - PN# E 6TH ST KEARNEY NE

Operating Manual. Model 0.4% Model 1% Model 2.5% Model 5% Model 10% Model 20% Fluid Flow Range: 0.03 gpm to 12 gpm* 7 lph to 2,700 lph*

SUPERDOS 20. Installation & Operating Instructions. Model No. SuperDos %, 2.5%, 5%, 10% Certified ISO 9001:2000 Quality Management System

MINIDOS. Installation & Operating Instructions. Model No. MiniDos - 0.4%, 2.5%, 5%, 10%, 20% Certified ISO 9001:2000 Quality Management System

0.7 m 3 /h - 3 GPM D 07 RE 125 D 07 RE 5. owner s manual

systems europe Twist II Clean Filters Product Catalogue

T100 Hybrid/T200 Hybrid

DI GPM Operating Manual

owner s manual 11 US GPM RANGE The diaphragm Dosatron CUSTOMER SERVICE - SERVICE CLIENTÈLE MANUFACTURED BY - FABRIqUé PAR DM 11 F DM 11 RE 3

THE DOSMATIC ADVANTAGE. INSTALLATION AND OPERATING MANUAL For A20-2.5% Model

MAINTENANCE MANUAL DI 16

2.5 m 3 /h - 11 GPM. manuel d utilisation owner s manual gebrauchsanweisung manuale d uso manual de utilización gebruiksaanwijzing

Value Super Filter Max Installation Manual

Full Flow Drinking Water System Model: 3MFF100

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Nelsen Filtration Cartridge Systems

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Foam Output 50 gal/min (190 ltr/min) 65 gal/min (246 ltr/min) Foaming Distance 30 feet (9 meters) 35 feet (10 meters) alcohols, ketones.

Colt Series C400, C500

Installation, Operation and Maintenance Manual

Spin Klin 3"-4" Apollo Angle

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

THE DOSMATIC ADVANTAGE. INSTALLATION AND OPERATING MANUAL For all A15 Models

4" Spin Klin Twin Apollo Battery. Service & Maintenance Manual

Spin Klin 4" Apollo Twin

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

Model 1100 Turbine Flow Meter

MODEL 900 IMPELLER-TYPE FLOW METER

Scale Feeder Manifold Water Filtration System Instruction Manual

D Instructions/Parts. Siphon Feed Detail Spray Gun D

Installation, Operation and Maintenance Manual

JET METER INSTRUCTIONS

Digital Print-out Test Kit for Backflow Preventer Assemblies

Intended Use: Explanation of Signal Word Consequences

UNIMIX EM. Operations Manual. Supplied by:

Dual Flow Manifold Systems Instruction Manual

MODEL 200 MULTI-JET FLOW METER

1/2" AIR DRIVEN DIAPHRAGM PUMP

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

Dual Port Manifold Water Filtration Systems Instruction Manual

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

MODEL 200 MULTI-JET FLOW METER

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Installation Instructions

INSTALLATION, OPERATING AND SERVICE MANUAL

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

SAFETY INFORMATION & INSTRUCTION MANUAL

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Operator's Manual. Models (¾") (1") (1½ ) (2 ) (3") (4") (6") (8")

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Installation Service Repair Kits Maintenance RP/IS-774/774DCDA/774X/774XDCDA

In-Line Fluid Meters Models: Liter Pint Quart Gallon

BUG PREP KIT 2.0 HAND-PREP SYSTEM. User Manual REV A reva0616

DP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10

Medi-Flow. Model M101 & M101D Medicator Instructions GETTING TECHNICAL ASSISTANCE

DEMA MIXRITE PROPORTIONING PUMP MODELS 574 & CL & 575CL FOR CORROSIVE LIQUID CHEMICALS INSTALLATION INSTRUCTION.

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

DP3 Pump. 3:1, Air-operated, Oil. General. Operation. Technical Data. Installation R0 10/09. 35a 35b 35c

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

23200 Navigator Dilution Control System 4 Button Model (NAV 4)

CRD600 Automatic Fitting Inserter

Air Actuated Dispense Valve

Maintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC

MK Rittenhouse & Sons Ltd. 115 Litre/30 US Gallon Greenhouse Sprayer Manual

PRO ES Test Fixture, High Voltage Test Probe, & KV Meter

1 CONDIMENT DISPENSING SYSTEMS MODELS MCD-1 & MCD-2

CRD610 Automatic Fitting Inserter

Maintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

P-200 Plastic Utility Pump for Petroleum Products

Pro Shot Grease Dispense Valve

or OWNER S MANUAL MODEL R

Port size: 1 NPT Shaft size: 5/8 Solid or 1/2 Hollow. Pump shaft rotation: CW Standard/CCW Optional. Weight: 19 lbs. Rollers: Ultra Rollers standard

Air Actuated Dispense Valve

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14

ARKAL SCREEN LINE H - SERIES Hydraulically Operated Self-Cleaning Screen Filter SERVICE & MAINTENANCE MANUAL

HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS INSTRUCTION MANUAL

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

665 Series Dispenser. Metering tip kit

T1-Titanium Non-HVLP Spray Gun

Spray Nozzle Adapters

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

Features and Benefits Wide Bottom: Translucent Bottle: 2 1/2 Gallon Bottle: Removable Bottle: Large cap: 15 Feet of Coiled Hose:

G8 Portable Fuel Transfer Pump Owner s Manual

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Certo Chemical Dilution System

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

SPECIFICATIONS CONTENTS: Specifications Warning Information. Operating Instructions Preventative Maintenance and Troubleshooting

Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers

Maintenance Manual Double Check and Double Check Detector Assemblies Series 850, 856, 870V & 876V 2 1 /2" - 10" (65 250mm)

www. hydrofuse.com Installation Manual Fertilizer Machine V1.3

VP12 High Viscosity Piston Pump

INSTALLATION INSTRUCTIONS DEMA BLEND CENTER MODEL B-GAP, T-GAP

Air Control Kit INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

Series 867 Reduced Pressure Zone Assemblies

OWNER S MANUAL D.E. CARTRIDGE. Installation Operation Parts. Models PCDE-30 PCDE-40

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Operating instructions Form no safety definitions

Transcription:

systems company Operating Manual - Adjustable Lower End Model 0.2% - 2% WSP Model 0.78% - 5% WSP Fluid Flow Range: 0.04 gpm to 11 gpm 10-2500 l/hr Injection Range: 0.2% to 5% 1:500 to 1:20 Operating Pressure: 5 to 90 psi 0,3 to 6,2 bar

0.04 11 gpm 5 90 psi 10 2500 l/h 0,34 6,2 bar Quick Start Guide

Contents Package Contents...4 Specifications...4 Safety Precautions...5 Warranty Compliance...5 General Tips...5 Operations...6 Installation and Start-up...7 Suggested Installation Diagram...7 Maintenance...8 Routine Maintenance Instructions...9 Troubleshooting...10 Injector Repair Parts...11 Lower end injector parts 0.2% - 2% Wettable Powder:...12 Lower end injector parts 0.78% - 5% Wettable Powder:...13 Warranty...14 Contact...15 Please read this manual carefully before putting the Hydro Systems injector into operation. This booklet has the information you will need for the use and care of your new Hydro Systems injector. If you have any further questions about your injector, the warranty, routine maintenance or proper usage, please contact your nearest distributor or Hydro Systems customer service. These models are designed to inject liquid concentrate or soluble powder that are recommended and approved for injection into fl uid systems. lt is the responsibility of the operator to determine the correct dosage settings of the unit using the chemical manufacturers recommendation for dispensing their product, and to assure that proper dosage is being maintained. Maintenance and Warranty Hydro Systems offers a one year limited warranty from the original date of purchase for manufacturing or materials defects only. With proper use and care, your injector should provide you long-term performance. Please review the complete warranty information on page 16. For Your Records The serial number of your Hydro Systems injector is located on the injector body. Please record this number in the space below and reference it when calling your distributor or Hydro for information, parts and service. Serial #... Date Purchased... This document does not form a contractual engagement on the part of Hydro Systems and is for information only. Hydro Systems reserves the right to alter product specifi cations or appearance without prior notice.

Package Contents AquaBlend Injector (not shown) Dosage gasket Quick Start Guide (not shown) The injector is packaged with the following items: Mounting Bracket Mounting Pins Filter Suction Tube Wettable Powder NPT BSP 0.2% - 2% 117947WSP 117957WSP 0.78% - 5% 117948WSP 117958WSP Specifications AquaBlend (90 max. psi) Model 0.2% - 2% (1:500-1:50) Model 0.78% - 5% (1:128-1:20) Flow Rate: 0.04-11 gpm (10-2500 l/h) Operating Pressure: 5-90 psi (0,3-6,2 bar) Pipe Coupling: 3/4 npt/ght/bsp Housing Dosing Accuracy Polyacetal (POM) +/- 10% of ratio Repeatability +/- 5% Pressure Loss Available Upon Request Maximum Temp. 100ºF/38= C Minimum Temp. 34ºF/ 1 C Maximum vertical suction of concentrate Maximum horizontal suction of concentrate Self-Priming Seal Material Available: Maximum Viscosity Recommended Accessories 13 Feet/396 Centimeters 49 Feet/1493 Centimeters Yes Viton - acids, oils & pesticides Alternative material available upon request. 2,000 cp (Ex. Honey) 140+ mesh fi lter, check valve, pressure regulator, fl ow restrictor. 4

! Safety Precautions Warranty Compliance Warning, Please read precautions thoroughly before operation. Must meet all applicable local codes and regulations. Remove Red Caps Prior to Installation Your injector is 100% factory tested before delivery and may contain a small amount of water. The three red plastic caps are fi tted after testing to ensure cleanliness of the injector. Before Applying Aggressive Chemicals Please consult your distributor, chemical manufacturer or contact Hydro's customer service to confi rm compatibility with your injector. Always wear proper safety protection as recommended by chemical supplier. Label all Fluid Lines, Valves and Connections If the solution that is being injected is not suitable for drinking, all fl uid lines should be labeled: Warning not for human consumption! Monitor Outlet Flow It is the user's responsibility to monitor the output of chemical injected. A Filter is Recommended and Required Install a fi lter of 140 mesh (104 micron) or fi ner depending on your fl uid quality to prolong the working life of the injector and for the warranty to be valid. A fi lter is imperative since most fl uid contains impurities or particles, especially if the fl uid source comes from a well, pond or lake. Avoid a Potentially Hazardous Chemical Accident Select a safe location. Chemical container should be kept away from children and/or high usage areas and the location must also not be susceptible to freezing temperatures. Avoid Solution Contamination Use only clean FILTERED fl uid. Do not allow contaminants to enter the solution container. Dirt, debris and other contaminants in the solution container may cause excessive wear to the unit. Fluid Temperature Min: 34 F (1 C) Max: 100 F (38 C) Maximum Fluid Pressure 90 psi (6,2 bar) Install a pressure regulator and/or pressure relief valve to ensure operating pressure does not exceed the maximum specifi cation. Before Removing An Injector From The System Release fluid pressure. While the system is in operation, turn off the incoming fl uid valve. Leave the out going valve open this will relieve the pressure at the injector and all parts of the system after the injector. Injector is now safe to remove. General Tips Please read this instruction manual thoroughly. Following the procedures, will increase the life of your injector. For A Long Service Life Start with clean fl uid by using an inline fi lter to reduce impurities. Keep the solution container covered and clean. Keep the suction tube fi lter off the bottom of the container. Perform maintenance procedures as recommended (see Maintenance page 8). Soluble Powder Use Ensure the chemical is completely dissolved before starting the injector. If necessary, dissolve the chemical in hot water and allow to cool before using. Failure to thoroughly dissolve the chemical will cause premature wear to the dosage piston/gasket and the inner cylinder. Keep From Extreme Temperature Protect the injector from freezing temperatures or excessive heat. Rinse Injector After Each Use Additive allowed to remain in injector can dry out, foul or damage the lower end at the next start-up (see Maintenance page 9). Injector Not in Use for an Extended Period If the injector has not been stored properly deposits may have dried onto the motor (see Maintenance page 8). Before operation, soak entire unit into room temperature water approx. 72 F (22 C) for a 24 hour period. 5

Operations Clicking Sound is Normal Fluid fl owing through the injector will automatically cause the injector to click and inject a set amount of solution into the fl uid line. The higher the fl ow rate the more frequent the "clicking". The injector is designed to inject solution proportionally (at the same set ratio) regardless of fl uid fl ow. Maximum number of clicks per 15 seconds is 50. Service Fluid Flow Fluid fl ow and pressure must be within the established specifi cations (see Specifi cation on page 4) for your model. Change Feed (Injection) Rate The feed rate on the injector is adjustable EVEN WHILE OPERATING AND UNDER PRESSURE. To change feed rate see (Fig. 1 and Fig. 2). Do not remove #79 when injector is under pressure. 1. Lift lock ring on (#7) (Fig. 1). 2. Rotate Ratio Adjuster Sleeve (bottom of #7) (Fig. 2) up or down to the desired setting. Use arrows at top of the Ratio Adjuster Sleeve to line up with the desired feed rate on the sleeve. 3. Return ring to lock position by pushing down on ring. NOTE: Do not screw Ratio Adjuster Sleeve below lowest setting line. Measure outlet fl uid to assure desired feed rate is being delivered. Fig. 1 Bleed Port Ensure all air is out of the unit by pressing the bleeder button in until water comes out. Release bleeder button to stop water from fl owing out of bleed port. Lock Ring Ratio Adjuster Fig. 2 Fig. 4 Typical wall mounting 6

Fluid Filter (Required) Install a fi lter of 140 mesh (104 micron) or fi ner depending on your fl uid quality to prolong the working life of the injector and for the warranty to be valid. Hydro recommends a Twist II Clean fi lter that can be ordered with your injector. Mounting Injector Securely fasten your injector to a solid object such as a wall or in a cold fl uid line. Note arrow on injector indicates fl uid fl ow. Backflow Preventor (Recommended) Install one that meets local code requirements. Pressure Safety Release Device (Recommended) Prevents pressure from exceeding specifi cations of the unit. Bypass Valve Set-up (Recommended) Allows the injector to be taken off-line for maintenance or storage when not in use. Fluid-Hammer Arrester (Recommended) Prevents fl uid-hammer damage to the injector when operating quick closing solenoid, pneumatic or hand-operated ball valves on the fl uid system. Anti-Siphon Valve (Optional) To prevent solution from being siphoned out (from the solution container) into the feed lines when the upstream valve is shut off. The anti-siphon valve must be installed on the downstream outlet. Installation and Start-up Refer to Fig. 4 and Fig. 5 Fig. 5 Additional Siphoning Prevention Place solution container on a level below the injector suction tube fi tting. Using the inlet side as a shut-off valve could cause full strength solution to siphon into the feed line. Solution Container Use any size container. A lid or cover is recommended. To connect your solution container, gently push the end of the suction tube onto the bottom of the suction tube fi tting assembly. Place the fi lter into the solution container at least 2" above the bottom and fi ll with at least 2" (5cm) of chemical solution. Never Use Petroleum Based Lubricants The injector is shipped with a thin coat of silicone around the seals for ease-of-assembly. Petroleum based lubricants such as Vaseline, baby oil, WD40, or motor oil on the O-rings or any part of the injector should never be used as this can cause particles to adhere and clog or damage the injector. Check System for Leaks and Start-Up Procedures Open the bypass valve (A), close inlet valve (B) and outlet valve (C) to prevent fl uid fl ow into the injector. SLOWLY turn on the main fl uid line. Run fl uid fl ows between 5-10 gpm (1100-2200 l/hr) through the plumbing system. Turn on all of the valves located downstream from your injector to release trapped air. SLOWLY turn on the inlet valve (B). Open the outlet valve (C) and close valve (A). As fl uid travels through the injector, you will hear a clicking sound. Check for leaks and correct if necessary. Suggested Installation Diagram! A B C 7

Maintenance Reference numbers refer to Page 11-13 RINSE INJECTOR AFTER EACH USE Additive allowed to remain in injector can dry, foul or damage the lower end at the next start-up. Place suction tube into a 1 qt. (0.95 liters) or more container of fresh fi ltered water. Flow fresh water through the injector by operating until container is empty. This procedure is not needed for continuous operation. CLEAN SOLUTION CONTAINER Keep covered to prevent dirt, and other debris from entering the container. Rinse container thoroughly and often. Do not mix chemicals together that might react and cause a precipitate. Use FILTERED fl uid when fi lling container. CLEAN SUCTION TUBE FILTER SCREEN Inspect each time new solution is added. Clean fi lter screen and suction tube (#25) as necessary by rinsing in fresh water. Replace if necessary. Keep fi lter screen off bottom of solution container to prevent dirt and precipitate from clogging fi lter. CLEAN INLET FILTER Clean or replace inlet fi lter as required to increase the life of the unit as well as reduce pressure loss. BYPASS INJECTOR When not in use place the injector in bypass mode by using the three valve bypass. STORAGE For extended storage, rinse injector using a minimum of 1/2 gallon. (see "Rinse Injector After Each Use") Drain water from unit. Inspect lower end seals. Apply thin coat of silcone to seals and reassemble unit. Place plugs back into inlet/outlet & suction tube fi tting. KEEP FROM FREEZING. Perform these maintenance procedures to extend the life of your unit. NOTE: Maintenance intervals may vary depending on conditons of use and the chemicals being injected. Every 3-6 Months 1. Clean Seal areas #44. 2. Clean & Check #64 Seal, #68 Cylinder, clean and/or replace as necessary. 3. Clean Filters Every 6-12 months 1. Replace Dosage gasket #44. 2. Clean and/or replace Check Poppet, inside #11 Suction Tube Fitting. Replace as necessary 1. #68 Cylinder 2. #64 O-ring/ Gasket 3. Motor Piston#9 4. #51 & #44 Shaft Assembly Dosage gasket 5. Check Valve Assy & Tubing 8

Routine Maintenance Instructions Step 1. Unscrew and remove lower end from assembly. Step 2. Pull down on shaft, rotate shaft 90 and remove. Step 3. Remove shaft with gasket and install new. If damage on sealing surface of shaft, replace shaft. Step 4. Hold body fi rmly and unscrew the lid. If lid is tight, use 1" (25mm) socket to loosen. Step 5. Remove motor piston from pump body. Step 6. Place new motor piston carefully into pump body and replace lid. Step 7. Place shaft into the motor piston. Step 8. Rotate shaft 90 to lock into place. Gently pull down to ensure shaft is locked. Step 9. Replace lower end assembly onto the pump body. 9

New Install - Always Pressure Up Slowly (Follow start up on page 8) Problem Cause Solution Fluid not fl owing through unit Troubleshooting Are the red plugs at the inlet, outlet and suction tube fi tting openings removed? Is the unit installed backward? The arrow on the unit must point in the direction of the fl uid fl ow. No Clicking Sound Fluid fl owing through unit If still not clicking, do not open the upper body. Call Hydro Systems Customer Service. Fluid rate is below or exceeds rated service fl ow of injector. (see Specifi cations for maximum fl ow rate page 4). Maximum number clicks = 50 in 15 seconds. Ensure all air is out of the unit by pressing the bleeder button in until water comes out. If below increase fl ow rate, if above, reduce fl ow rate. Operating pressure exceeds maximum limit. Install a pressure reducer valve. (see Specifi cations for maximum fl ow rate page 4). Injector in Operation or After Scheduled Maintenance Problem Cause Solution No Clicking Sound Air trapped in unit By-Pass Valve not open Broken Springs Dirty or plugged inlet fi lter Main Piston Assembly #9 worn Main body #1 worn or scored Release trapped air by pressing the bleeder button in until water comes out. Set Valve to the closed position. Replace Springs #18, Clean Fluid Filter. Ensure mesh size is correct for proper fi ltration. Clean fi lter. Replace #9 Main Piston Assembly. Clean fl uid fi lter. Replace Body & Piston. Problem Cause Solution Clicking Sound No Suction Of Solution Cracked or loose Suction Hose Dosage gasket #44 worn or installed incorrectly Suction tube #25 or suction tube fi tting #11 cracked, leaking or clogged suction tube fi lter Check valve #11 leaking Check for proper fi t and /or replace. Replace. Ensure during maintenance replacement that #44 dosage gasket was installed correctly. Replace and/or clean as necessary. Clean and/or replace as necessary. Problem Cause Solution Clicking Sound. Under Injecting or Unit operates at high-flow and not at low flow #44 Dosage gasket worn Replace. #68 Inner Cylinder worn Replace Inner Cylinder and Gasket #44 Broken Springs Replace Springs, Clean Fluid Filter. Main Piston Assembly #9 worn Replace #9 Main Piston Assembly. Clean fl uid fi lter. Main body #1 worn or scored Replace Body & Piston Problem Cause Solution Fluid Re-filling Solution Tank Check valve #11 leaking or dirty Washer seal on #11 is swollen or chemical attack Check seat area on suction tube fi tting #11. Check valve and seal must fi t loose in the suction tube fi tting. Clean seal and inside fi tting for debris. Replace with new check valve assembly. 10

Injector Repair Parts Part # 102801NPT 102801BSP Kit H - 017200 (includes 017201) Kit S - 017201 Kit L - 017202 Kit M - 011732 Description of Part Body, Adjustable AquaBlend NPT Body, Adjustable AquaBlend BSP Motor Piston Replacement Motor Springs, Replacement Replacement Cover Kit Mounting Bracket Kit 18 11

Lower end parts 0.2% - 2% Wettable Powder: Part # Description of Part Kit A - 017210WSP AquaBlend 0.2% - 2% Adjustable WSP Wear Kit A Viton Kit B - 017211WSP AquaBlend 0.2% - 2% Adjustable Wear Kit B Viton Kit D - 017213WSP AquaBlend 0.2% - 2% Adjustable Wear Kit D Viton Kit E - 017214WSP AquaBlend 0.2% - 2% Adjustable Wear Kit E Viton Kit F - 017215WSP AquaBlend 0.2% - 2% Adjustable Wear Kit F Viton Kit G - 017216WSP AquaBlend 0.2% - 2% Adjustable Wear Kit G Viton 10095359 Pick Up Tube Assembly 0.2% - 2% Adjustable 12

Lower end parts 0.78% - 5% Wettable Powder: Part # Description of Part Kit A - 017220WSP AquaBlend 0.78% - 5% Adjustable WSP Wear Kit A Viton Kit B - 017221WSP AquaBlend 0.78% - 5% Adjustable Wear Kit B Viton Kit D - 017223WSP AquaBlend 0.78% - 5% Adjustable Wear Kit D Viton Kit E - 017224WSP AquaBlend 0.78% - 5% Adjustable Wear Kit E Viton Kit F - 017225WSP AquaBlend 0.78% - 5% Adjustable Wear Kit F Viton Kit G - 017226WSP AquaBlend 0.78% - 5% Adjustable Wear Kit G Viton 10095356 Pick Up Tube Assembly 0.78% - 5% Adjustable 13

Warranty Congratulations on Your Purchase We make the best and most reliable fl uid-driven injectors available. Hydro Systems will provide for replacement of all parts proven to be defective in material or workmanship from the date of purchase for the following periods: 1 year Covers your unit from manufacturing and material defects only. Hydro Systems products are warranted to be free from defects in materials and workmanship for the above time frames. Hydro Systems will at its sole option repair or replace any component that fails in normal use. Any repairs made under warranty shall not extend the initial warranty period. To Maintain Your Warranty Your only responsibility is ordinary maintenance - fi ltering incoming fl uid, replacing the O-ring and dosage piston/ gasket when worn. Seals and O-rings are not covered under the warranty. This warranty is not valid if the defects are found to be due to the product s misuse, lack of maintenance, fl uid impurities such as sand or iron, defective installation, freezing, fl uid hammer, abuse, unwanted side effects due to the chemicals you choose to inject or service provided by anyone who is not an authorized service provider. Hydro Systems declines any responsibility if the product is not used in compliance with the operating instructions and specifi cations as indicated in this owner s manual. IN NO EVENT SHALL HYDRO SYSTEMS BE LIABLE FOR ANY INCIDENTAL, SPECIAL; INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM THE USE, MISUSE OR INABILITY TO USE THIS PRODUCT OR FROM DEFECTS IN THE PRODUCT. There is no warranty expressed or implied relating in any way to products used in conjunction with Hydro Systems. Hydro Systems or authorized distributor shall not be liable for incidental or consequential damage, such as any economic loss. Hydro Systems retains the exclusive right to repair or replace the product. Such remedy shall be your sole and exclusive remedy for any breach of warranty. There are no warranties, expressed or implied, which extend beyond those described above. To Return an injector for Warranty or Non-Warranty repair: Contact Hydro Systems Company or your local distributor for return information. 14

For the latest updates or modifications, please check our website at: www.hydrosystemsco.com systems company Global Headquarters Hydro Systems Company 3798 Round Bottom Road Cincinnati, OH 45244 U.S.A. T 513-271-8800 F 513-271-0160 Toll Free: 1-800-543-7184 www.hydrosystemsco.com European Offices Hydro Systems Europe Unit 3, The Sterling Centre Eastern Road Bracknell, Berkshire RG12 2PW England T +44 (0)1344 488880 F +44 (0)1344 488879 Asia Pacific Offices Hydro Systems Asia Pacific Unit A, 1 Kelham Place Glendenning NSW 2761 Australia T +612-9625-8122 F +612-9625-8177 South America Office Hydro Systems South America Rua Mogiana, 172, Chacarras Reunidas Sao Jose Dos Campos 12238-420SP Brasil T +55-12-3201-7707 www.hydronovabrasil.com Hydro Systems Bordeaux France 20 Route de Taillefer 33450 Montussan T +33 (0)5 57 97 13 13 T +33 (0)5 57 97 13 13 FREE F +33 (0)5 57 97 10 19 www.hydrosystemseurope.com Hydro Systems Asia Pacific Block #B, No. 51 Mingdong Road Pudong New Area Shanghai, PRC 201209 T +86 21 61871037 F +86 21 68727775 Hydro Systems Asia Pacific 762/2 Room A540 Rama 3 Road Bang Pong Pang Yannawa, Thailand T +66 2 295 2788 F +66 2 295 2785 www.hydrosystemschina.com 10097063 Rev. A 4/13 15