BA Series Terminal Blocks

Similar documents
BA Series Terminal Blocks

BA Series. UL Recognized File No. E Specifications. Power Blocks Part Numbers BA111TU2 BA211TU BA311TU BA411SU

Terminal Blocks. Selection Guide. Selection Guides. P-2 USA: (800) 262-IDEC or (408) , Canada (888) 317-IDEC

Terminal Blocks. Switching & Controls.

Terminal Blocks. BNH/BN Terminal Blocks. BNH/BN Series. Specifications. USA: (800) 262-IDEC or (408) , Canada: (888) 317-IDEC P-3

This document provided by Barr-Thorp Electric Co., Inc

TREICHL-ATM Electronic

Section. Terminal Blocks Selection Guides...P-2

Terminal Blocks. BN Power Blocks. BN Power Block Series. Specifications

RU Series Universal Relays

PS5R-S. Switching Power Supplies

GT5P Series ON Delay Timers

Circuit Protector Selection Guide

AP/UP Series Miniature Pilot Lights UZ Series Miniature Buzzer

ø12 A2 Series Miniature Control Units

ø8 A8 Series Miniature Control Units

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches

Solenoid Locking Safety Switches

ø10 A1 Series Miniature Control Units

Relays & Sockets. RQ Series PCB Relays

Miniature Switches & Pilot Devices

Relays & Sockets. RR Series Power Relays. Part Number Selection. Key features: Sockets IDEC (4332) USA & Canada

PS6R 480W Switching Power Supply

TPC TYPE N21 FEATURES. [Conformable standards] UL1059(2004) File No.E82309 EN Certificate No.B Ground terminal block

Distinctive Characteristics

Power Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs.

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

HS1L Interlock Switches with Solenoid

Oiltight Switches & Pilot Devices

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1

HS1C-P Interlock Plug Unit with Door Lock

AP Series / UP Series Miniature Pilot Lights UZ Series Miniature Buzzer

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

Bright illumination face and snap-action switching.

HS1E Series Full Size Interlock Switch with Locking Solenoid

Oiltight Switches & Pilot Devices

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

HL (AZH) LIMIT SWITCHES

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) A22E/A22NE-P

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Lighted Pushbutton Switch

HS1C Interlock Switches with Solenoid

Door Interlock Switches

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies

Electronic Circuit Breaker ESS20-0..

Industrial Relay KML(1C, 2C)

T CLASS T FUSE BLOCKS

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

2600 SERIES ILLUMINATED AND NON-ILLUMINATED ROCKER SWITCHES Overview

XA Series Emergency Stop Switches (w/removable Contact Block)

HEAVY DUTY POWER RELAYS FEATURES

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

VA-8020 Floating Valve Actuator

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

HS1E Series Full Size Solenoid Locking Switches

Fuse holders and fuses

HL (AZH) Limit Switches

RY2L Series Miniature Magnetic Latching Relays. E Release Time. 60N (0 6G); Maximum frequency 55Hz

General Purpose Relay

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Distinctive Characteristics

SX5 Series Smart I/O (General Information)

Non-illuminated Push Buttons

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

table of contents Switches J 1 SECTION SECTION J Quick Guide to Switches... J2-J3

D4DL. Guard Lock Safety-door Switch. Model Number Structure

HL (AZH) Limit Switches

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

SL1Series. Compact Horizontal Limit Switches

Signaling Lights LD6A. LD6A LED SignaLight Towers Assembled Products. Unique Striped Design Improves Visibility

HS5D Miniature Interlock Switches

Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series

General Purpose Relay

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

XW Series Emergency Stop Switches


Thermal Overcurrent Circuit Breaker 3130

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Mechanical Min. 20 million operations. Min. 2 million operations for the Model SL1-B. Min. 2 million operations for high oil. (All values assume overt

Class T 300 & 600 Volt Fuse Blocks F B 300 & 600V CLASS T FUSE BLOCKS RATINGS: FEATURES/BENEFITS: RECOMMENDED FUSE USAGE: CLIP & CONNECTOR TYPES

EPIC. Connector Accessories CONNECTOR ACCESSORIES. Glands, Seal Rings & Adapters Glands 412 EPIC SM & SP Glands, EPIC CM-M Glands

Safety Limit Switch

Momentary pushbutton switches - round plunger

Distinctive Characteristics

Door Interlock Switches

Model Description IDEC Model

1200 series. Momentary pushbutton switches - round plunger. Distinctive features and specifications. Butt action contacts, double break

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

Thermal-Magnetic Circuit Breaker 201/-WA

Switching Power Supplies

Switching Power Supplies

Transcription:

Quick-mount terminal blocks for mounting on 35-mm-wide DIN rails. Current capacities from A to 400V (600V). Snaps on to 35-mm-wide DIN rails. Wide range of current capacities from A to 400A. Insulation voltage is 600V. No end plates are required. 3-pole units, fuse blocks with blown fuse indicators available. Large capacity types (BA811S, BA911S) can be mounted directly to panels. Material: polyamide (black) Complies with JIS C 811. UL recognized and CSA certified. (BA111T, BA11T, BA311T, BA411S, BAF111SU, BAF111SNU) Applicable Standards UL1059 Mark Certification Organization/ File No. UL recognized File No. E78117 CSA. No. 158 CSA (File No. LR64803) Quick-mount Unlatch Snap on Remove Push Pull No end plates required General Ratings Dielectric Strength Insulation Resistance Operating Tempera ture Storage Temperature Operating Humidity 500V AC, 1 minute 100MΩ minimum 5 to +55 C (no freezing) 5 to 70 C (no freezing) 45 to 85% RH (no condensation) Terminal Blocks Style Part No. Ordering No. UL/CSA JIS Tightening Terminal Package Voltage/ Wire Size Voltage/ Wire Size Torque Screw Quantity Current (AWG) Current (mm ) (N m) BA111T BA111TPN0 300V/15A -14 600V/A 1.5 mm ( mm ) M3 0.6 to 1.0 0 3-pole Self-Lifting BA11T BA11TPN0 300V/0A -1 600V/1A mm (3.5 mm ) M3.5 1.0 to 1.3 0 BA311T BA311TPN0 150V/30A 18-10 600V/40A 5.5 mm M4 1.4 to.0 0 Self-Lifting BA411S BA411SPN50 600V/40A -6 600V/70A 14 mm M5.6 to 3.7 50 BA611S BA611SPN10 600V/94A mm M6 3.9 to 5.4 10 BA711S BA711SPN06 600V/13A 38 mm M8 10 to 13.5 6 BA811S BA811SPN06 600V/40A 100 mm M10 1 to 8 6 Large Capacity 00 mm BA911S BA911SPN06 600V/370A (00 mm wires) M1 38 to 49 6 1-pole (35 mm 1 wire) Fuse BAF111S- BAF111S- PN0 600V/10A 5.5 mm M4 1.4 to.0 0 Fuse with Lamp BAF111SN- BAF111SN- PN0 600V/10A 5.5 mm M4 1.4 to.0 0 Without Fuse BAF111SU BAF111SUPN0 600V/10A 18-10 600V/10A 5.5 mm M4 1.4 to.0 0 WIthout Fuse/ With Lamp BAF111SNU BAF111SNUPN0 600V/10A 18-10 600V/10A 5.5 mm M4 1.4 to.0 0 With Disconnecting Switch BAT0 BAT0PN0 600V/0A 5.5 mm M4 1.4 to.0 0 1. Specify fuse ratings 1A, 3A, or 5A in place of in the Part No.. The wire size in ( ) does not comply with JIS standards. 3. The voltage/current differ according to operating conditions. See Selecting Terminal Blocks by Current According to JIS Standards on page 5. 4. Use a socket wrench or screwdriver for tightening screws. : Order when a marking strip or a dust cover is needed. : Used for surface mounting : Dust cover with fuse holder Part No. BA111T, BA411S, BAT0, BA11T, BA611S, BA711S, BA311T DIN End Clip Marking Strip ( Necessary) Dust Cover Connecting Rod Connecting Nut Surface Mounting Clip BA811S, BA911S BAF111S, BAF111SN, BAF111SU, BAF111SNU Material Parts Name Housing Bus Bar Terminal Screw Material Polyamide Brass (nickelplated) Steel (zinc chromeplated) 3 (1060)

BA111T (3 Pole) A M3 Standards UL/CSA JIS Insulation Voltage 300V 600V 5 38.5 7.9 7.9 Rated Current 15A max. A 6.7 Dielectric Strength,500V AC, 1 minute ø3. min. 6.6 max. -14 1.5 mm Wire Size 1 AWG ( mm ) 5 max. 3.3 min. BNC0 Weight: Approx. 18.8g 0.0 6-M3 Screw BAA/BAP: 3 BA11T (3 Pole) 1A M3.5 0.0 6-M3.5 Screw 9.8 30.5 9.8 8.5 38.5 Weight: Approx. 5.3g BAA/BAP: 3 8.4 max. ø3.6 min. 5 max. 4 min. Standards UL/CSA JIS Insulation Voltage 300V 600V Rated Current 0A max. 1A Dielectric Strength,500V AC, 1 minute Wire Size 1-1 mm AWG (3.5 mm ) BNC0 BA311T (3 Pole) 40A M4 0.4 6-M4 Screw 34.5 41 11 11 9.6 3 39 Weight: Approx. 40.0g BAA/BAP: 33.5 9.4 max. 6 max. ø4. min. 4.5 min. Standards UL/CSA JIS Insulation Voltage 150V 600V Rated Current 30A max. 40A Dielectric Strength,500V AC, 1 minute Wire Size 1 18-10 AWG 5.5 mm BNC30 BA411S 70A M5 50 Standards UL/CSA JIS 13 600V Rated Current 40A max. 70A Dielectric Strength ø5. min.,500v AC, 1 minute 1.8 max. Wire Size 1-6 AWG 14 mm 6.5 max. 4.5 min..8 -M5 Screw 48 Weight: Approx. 3.4g BAA/BAP: 37.5 BNC30 BA611S 94A M6 65 17 Rated Current 94A max. Dielectric Strength,500V AC, 1 minute ø6. min. Wire Size.8 max. mm 8.5 max. 6 min. 3.4 -M6 63 BAA/BAP: 43.5 Socket wrench: 1.7 mm square drive hexagonal socket 10 3 6.5 -M8 Hexaganol Bolt BAA/BAP: 51.5 Weight: Approx. 53.0g BNC50 BA711S 13A M8 3 0.5 65 3 Rated Current 13A max. Dielectric Strength,500V AC, 1 minute ø8.5 min. Wire Size 38 mm.8 max. Marking Strip 11 max. 8 min. Width BNC50 Weight: Approx. 103.3g Socket wrench: 1.7 mm square drive hexagonal socket 13 3 1: The wire size in ( ) does not comply with JIS standards. : The voltage/current differ according to operating conditions. See Selecting Terminal Blocks by Current According to JIS Standards on page 5. 3: Screws can be tightened with a socket wrench. *4: The grooves on the head of the hex bolt are for temporary tightening. For proper tightening, use an applicable socket wrench and tighten within the range of the recommended tightening torque. (1060) 33

BA811S 40A M10 Socket wrench: 1.7 mm square drive hexagonal socket 17 BA911S 370A M1 Socket wrench: 1.7 mm square drive hexagonal socket 19 Weight: Approx. 185.0g Weight: Approx. 406.3g 30.5 -M10 -M10 Surface Mounting Clip (BAL3) 4 85 33 Surface Mounting Clip (BAL3) ø4.5 Hole (or M4 Screw) 94 (P) 136 (3P) 94 (4P) 4 85 33 Surface Mounting 84 (BAL) 3.8 max. 60 1.5 max. 1.5 BAA/BAP: 61.5 ø10.5 min. 11 min. 37.5 -M1 -M1 60 140 51 Surface Mouting Clip (BAL3) Surface Mounting Surface Mounting Clip (BAL3) (BAL) 60 140 51 ø4.5 Hole (or M4 Screw) 130 (P) 190 (3P) 130 (4P) 10 50.8 max. 1.5 BAA/BAP: 78.5 77 1.5 6 max. ø1.5 min. 14 min. Part No. BA811S BA911S Rated Current 40A 370 (400A) Dielectric Strength,500V AC, 1 minute Insulation Resistance 100MΩ minimum Wire Size 100 mm 00 mm 1 (00 mm wires) (35 mm 1 wire) Terminal Screw M10 M1 Connecting Rod BNR1, BNR, BNL8 Connecting Nut BAN1 / Surface Mounting BAL, BAL3 Clip Marking Strip Width BAC80 BNC9 Use 3 surface mounting clips (BAL3) for 4-pole mounting Use 3 surface mounting clips (BAL3) for 4-pole mounting BAF111S (Fuse) 10A M4 -M4 Screw.5 10 63 36 BAA/BAP: 49 10 max. 5. max. ø4. min. 4.5 min. BAF111SN is equipped with a neon lamp (for 100 or 00V AC) which turns on when the fuse is blown. Internal Connection Fuse BAF111S (with fuse)/baf111sn (with fuse/lamp) Rated Current 10A max. (depends on fuse rating) Dielectric Strength,500V AC, 1 minute Insulation Resistance 100MΩ minimum Wire Size 5.5 mm Terminal Screw M4 9.5mm (BNM7, BNM9, Fuse ratings Rated voltage: 50V Rated current: 1, 3, 5A Cartridge fuse: JIS C6575-6.35 31.8 mm Part No. BAF111S-1A BAF111S-3A BAF111S-5A BAF111SN-1A BAF111SN-3A BAF111SN-5A Neon Lamp BAF111S (with fuse)/baf111sn (without fuse/with lamp) Rated Current 10A max. (depends on fuse rating) Dielectric Strength,500V AC, 1 minute Wire Size 18-10 AWG Terminal Screw M4 Use UL/CSA approved fuses (10A maximum) Fuse size 6.35 31.8 mm 6.40 30 mm BAT0 (With Disconnecting Switch) 0A M4 10 65 Rated Current Dielectric Strength 0A,500V AC, 1 minute Wire Size 5.5 mm max. Terminal Screw M4 ø4. min. 9.5 mm (BNM7, BNM9) 10 max. BNC50 63 6.4 max. 4.5 min. BAT0 is not capable of breaking circuits. Do not apply voltage when opening or closing the circuit. Turn the slot using a screwdriver. -M4 Screw.5 BAA/BAP: 39.5 1: The wire size in ( ) does not comply with JIS standards. : The rated current differs according to operating conditions. See Selecting Terminal Blocks by Current According to JIS Standards on page 5. 3: The grooves on the head of the hex bolt are for temporary tightening. For proper tightening, use an applicable socket wrench and tighten within the range of the recommended tightening torque. 34 (1060)

s DIN 35-mm-wide 5.5 1.5 7.5 35 5 1.5 BAA:1.7 BAP:1 BAA BAP BAA:31 BAP:7 BAA BAP Length Part No. Ordering No. Material Weight (Approx.) Package Quantity BAA1000 (Note) BAA1000PN10 Aluminum 00g 10 1000 mm BAP1000 BAP1000PN10 Steel 30g 10 Note: 000 mm is also available. Contact IDEC. Marking Strip (BNM) Part No. Ordering No. Package Quantity Dimensions Material BNM7 BNM7PN10 10 9.5 0.5t 1m PVC (glossy surface) BNM9 BNM9PN10 10 9.5 0.5t 1m Fiber Glass (matte surface) BNM75 BNM75 1 9.5 0.5t 5m PVC (glossy surface) BNM3 BNM3PN50 50 Used on the ends of a group of terminal blocks to secure and prevent sliding along the rails. Part No. Ordering No. Package Quantity BNL6 BNL6PN10 10 BNL8 BNL8PN10 10 BAL BALPN10 10 45 4 BNL6 (M4 Screw) (Tightening torque: 1.1 N m) 9 46 BNL8 (M4 Screw) 3.5 14.4 Material: Steel (zinc chrome-plated) 45 6 (35) 1 BAL (Weight: Approx. 5.g) Notes on Selecting s BA611S, use BAL or BNL8. Also, when using BA711S, BA811S, BA911S of 100A or larger, use BAL or BNL8. When mounting rails vertically, use BAL or BNL8. Material: Polycarbonate Item Part No. Ordering No. Size (mm) A B Terminal Block Package Quantity BNC0 BNC0PN10 37.6 8.5 BA111T, BA11T 10 BNC30 BNC30PN10 39.6 8.5 BA311T 10 (1m) BNC30 BNC30PN10 49.6 8.5 BA411S 10 BNC50 BNC50PN10 65.0 9.0 BA611S, BA711S, BAT0 10 BAC80 BAC80PN10 85.0 10.6 BA811S 10 (500 mm) BNC9 BNC9PN10 140.5 9.8 BA911S 10 (1060) 35

Connecting Rod/Connecting Nut (For BA811S, BA911S) BNR1: M4 0.7 L = 65 (1.0g) BNR: M4 0.7 L = 500 (43.0g) BAN1: M4 0.7 (.5g) Item Part No. Ordering No. Weight (Approx.) Package Quantity Remarks Connecting Rod (65 mm) BNR1 BNR1PN10.6g 10 M4 0.7 Connecting Rod (500 mm) BNR BNRPN10 43g 10 M4 0.7 Connecting Nut (4 pcs/set) BAN1 BAN1PN10.5g 10 M4 0.7 Surface Mounting Clip (For BA811S and BA911S Only) Used on the ends of groups of terminal blocks for direct mounting to panels. Part No. Ordering No. Weight (approx.) Package Quantity BAL3 BAL3PN10 1.4g 10 Material: Steel (zinc-chrome plated) BAL3 Calculating / Connecting Rod Length BA411S BA611S BA711S BA811S BA911S BA111T BA11T BA311T BA111SN BAF111S BAT0 5 30.5 34.5 3 L (Mounting Centers) 4 60 L1 ( Length) L L1 Calculating Length For BAA, BAP rails L 1 = 1.5 N L = L 1 5 A: Total thickness of each terminal block B: Tolerance of stacking thickness 0.1 mm per block C: pieces of BNL6 or BAL = 6.5 N: Rounded up numerical number from the calculated value of M. (Example: N for 19.1 is 0) M = A + B + C 1.5 Note: This formula is for calculating the maximum rail length including tolerance. The rail length may be shorter than the calculated value, depending on how the terminal blocks are combined. Calculating Connecting Rod Length L = 4 n 1 + 60 n + 10. n 1 : BA811S n : BA911S n: The number of terminal blocks 36 (1060)

Instructions Installation of BA811S and BA911S Connecting Rod BNR Connecting Nut BAN1 BAL Surface Mounting Clip BAL3 Notes on Wiring Crimping Terminals crimping terminals, be sure to use insulated terminals to prevent electric shocks. Without Crimping Terminals Insert the wire until the insulation comes into contact with the terminal metal part. Strip the insulation so that the wire is longer than the width of the wire clamp. When connecting two wires, use wires of the same size. Mount 1. Mount the terminal block on DIN rail.. Mount the surface mounting clips (BAL3) on both ends and slide connecting rods (BNR) through the holes in the terminal blocks. 3. Tighten both ends of the connecting rod with a connecting nut (BAN1). 4. Secure the terminal blocks with end clips (BAL). Surface Mount 1. Mount the terminal block to the panel.. Mount the surface mounting clips (BAL3) on both ends and slide connecting rods (BNR) through the holes in the terminal blocks. 3. Tighten both ends of the connecting rod with connecting nuts (BAN1). 4. Secure the terminal blocks to the panel. Washer Width Terminal Metal Part Wire Insulation (1060) 37