Morgan Schaffer. Calisto Monitors. Maintenance. Presented by: Eric Thibodeau. Technical Support Specialist

Similar documents
Advanced Force / Torque Indicator

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard

Flash Point Process Analyzer

Fuel Cell Lab Manual. Non Conventional Energy Systems Facility. Non Conventional Energy Systems Facility. Boiler House

INSTALLATION AND OPERATION INSTRUCTION

SPD DEVICE USER MANUAL V1.2.

For more information about Agilent Technologies services please visit our web site using the following URL

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

INTECH Micro 2300-RTD6

Refrigerated incubator with Peltier technology

Issue 2.0 December EPAS Midi User Manual EPAS35

Quick Setup Guide for IntelliAg Model YP Air Pro

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

ZT-USB Series User Manual

Scout II Operation Instructions

Getting Started HONDA

FPA4 DATASHEET JUNHO 2013

TECHNICAL SERVICE BULLETIN

Application Engineering Europe

GE Sensing & Inspection Technologies

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

(KL) Jeep Cherokee

RMF SYSTEMS CONDITION MONITORING CENTER PURE POWER

MXL Pista / MXL Strada KIT FOR SUZUKI GSX R

Multi Wheel Bluetooth Tire Pressure Monitoring System User Manual Model: External

EPAS Desktop Pro Software User Manual

Product Guide: Series III Pump Control Board Set (RoHS)

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

HONDA VTX 1800C HONDA VTX 1800R INSTALLATION INSTRUCTIONS

UPGRADE PROGRAM. V141 Series Pumps vs Turbo-301 Series Pumps. Technical Memo

CFPP Process Analyzer

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

TECHNICAL SERVICE BULLETIN

Carbon Monoxide Transmitter

Wallbox Commander. User Guide WBCM-UG-002-EN 1/11

Instruction Manual Installation and Operation Guidelines for DWL5000XY and DWL5500XY Tilt Sensor Modules (Version 2.2)

Wind Tunnel User Guide V0814

Stratified MegasQuirt Plug and Play ND64

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS

Advanced User Manual

BMS16. Thanks for your purchasing the BMS16 for your vehicle.

Application. Tek-Air Systems, Inc. 41 Eagle Road Danbury, CT (203) FAX: (203) SALES FAX: (203)

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description

MXL Strada / Pista Plug and Play kit for Kawasaki ZX-10 R

IOM A-0984E IP68-420DC AUTOMATED PILOT ACTUATOR Installation and Operation Manual

Cannondale Diagnostic Tool Manual

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Agilent G4367A Auxiliary Electronic Pressure Control (Aux EPC) Module

12 VOLT BATTERY & ELECTRICAL SYSTEM ANALYSER

BERMAD Waterworks. Insertion Flow Meter Device (IFM)

Support. EMROL Your power partner

AiM Infotech. Plug&Play kit MXL Strada/Pista/Pro/Pro05 for Subaru Impreza Release 1.04

THYRO-PX SERIES DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS

Zoom and Print Options

TORQUE CALIBRATION USING THE PROEDIT PROCEDURE WIZARD AND CALIBRATING USING PROCAL

ATOTH-G Series BLDC Motor Controller. User s Manual

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

ENGINEERED TO ORDER SOLUTIONS

BMS24. Thanks for your purchasing the BMS24 for your vehicle.

CORNERING LIGHTING MODULE CLM02-CAN INSTALLATION MANUAL

TECHNICAL SERVICE BULLETIN

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Blancett Flow Meters A Division of Racine Federated Inc. 100 East Felix Street South, Suite 190 Fort Worth, Texas FAX:

MXL Pista / MXL Strada PLUG & PLAY KIT FOR SUZUKI GSX R

Indian Speedometer and Body Control Module Service Tool Users Guide

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28

QUANTUM LX CONTROL PANEL

9/11/2017 General Information (12) > [BOD051] Service Action: Power Tailgate IPM Update To Prevent Battery Discharge 2006 Kia Sedona MotoLogic

TPMS Adapter Instruction Manual. (Tire Pressure Monitoring System)

Subaru L Turbo

PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION

X117E. X117E Contact-Less Valve Position Transmitter INSTALLATION / OPERATION / MAINTENANCE MODEL. X117E Contact-Less Valve Position Transmitter

Touch plate serial number. Please save this info here for use later:

DIFFERENTIAL PRESSURE BATTERY CHARGERS

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

Installing a Purged Packed Inlet

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

ValveLink SNAP-ON Application

mass flowmeter for compressed air

Hydrovar and Packaged Hydrovar

8/18/2017 Throttle Position Sensor TSB Title: 10-FL /18/2010 Engine Controls - MIL ON/DTC's P2135/P0638

Note: If anything is damaged or missing, contact your customer representative immediately.

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

MIT515, MIT525, MIT1025, MIT1525

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

Air Fuel Ratio Module and AFR-4 Pump Assembly Installation and User Guide.

DKG-317 MANUAL AND REMOTE START UNIT

Power Switching Devices

ARCTIC CAT M8, M1000, F8, AND F1000 SNOWMOBILES INSTALLATION INSTRUCTIONS

HPLC Model 210D. UV detector lamp switch. Rheodyne 7725i injection valve. Prime/purge valve. Column. compartment. thumbscrews. Storage.

COMMISSIONING Tick the tests carried out by attendee.

MATRIX LLC LEVEL CONTROL PANEL

MXL Pista / MXL Strada PLUG & PLAY KIT FOR SUZUKI GSX R

ET9500 BEMS Interface Box Configuration Guide

PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION

DKG-109 AUTOMATIC MAINS FAILURE UNIT

Physical Property Analyzer PPA4100 Series. On-Line RVP Analyzer

PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION

Transcription:

Morgan Schaffer Calisto Monitors Maintenance Presented by: Eric Thibodeau Technical Support Specialist

Flushing of the oil lines

Purging the oil lines Step 1: All valves are closed Calisto Pump OFF OUTLET valve CLOSED INLET valve CLOSED Oil sampling Quick Connect port CLOSED RETURN valve CLOSED SUPPLY valve CLOSED

Purging the oil lines Step 2: Slowly open the transformer valves Calisto Pump OFF OUTLET valve CLOSED INLET valve CLOSED Oil sampling Quick Connect port CLOSED RETURN valve SUPPLY valve

Purging the oil lines Step 3: Open the OUTLET valve Calisto Pump OFF OUTLET valve INLET valve CLOSED Oil sampling Quick Connect port CLOSED RETURN valve SUPPLY valve

Purging the oil lines Step 4: Connect the Sampling port and flush 0.5 L of oil Calisto Pump OFF OUTLET valve INLET valve CLOSED Oil sampling Quick Connect port RETURN valve 0.5 L SUPPLY valve

Purging the oil lines Step 5: Close the OUTLET valve Calisto Pump OFF OUTLET valve CLOSE INLET valve CLOSED Oil sampling Quick Connect port RETURN valve 0.5 L SUPPLY valve

Purging the oil lines Step 6: Open the INLET valve Calisto Pump OFF OUTLET valve CLOSE INLET valve Oil sampling Quick Connect port RETURN valve 0.5 L SUPPLY valve

Purging the oil lines Step 7: Power ON the monitor and flush 0.5 L of oil Calisto Pump ON OUTLET valve CLOSE INLET valve Oil sampling Quick Connect port RETURN valve 1 L SUPPLY valve

Purging the oil lines Step 8: Disconnect the sampling tube Calisto Pump ON OUTLET valve CLOSE INLET valve Oil sampling Quick Connect port CLOSE RETURN valve SUPPLY valve

Purging the oil lines Step 9: Open the OUTLET valve Calisto OIL FLOW Pump ON OUTLET valve INLET valve OIL FLOW Oil sampling Quick Connect port CLOSE OIL FLOW RETURN valve SUPPLY valve

Calisto Manager

Installing Calisto Manager 1. Insert the CD or download the software from our website 2. Follow the on-screen instructions 3. At the Choosing Components step, make sure to check the USB Drivers box Notes: A notification window may appear, choose the Continue Anyway option Prior to starting Calisto Manager, your computer should be properly connected to the monitor using the supplied USB cable and proper drivers should be installed when asked by the operating system.

Connecting to a new Calisto 9 1. Launch Calisto Manager 2. Under Tracking, click on Add Monitor to List 3. At the Choosing Components step, check the USB Drivers box

Connecting to a new Calisto 9 4. Select Serial under Connection Type for local USB 5. Select the virtual COM create under Port 6. Click on Find (The monitor will appear in the Found Monitor window) 7. Click the Checkbox next to the monitor and click Add 8. The connected monitor will now appear in the list of monitors displayed in the main window

Calisto 9 Settings 1. Under the Tools menu, click on Advanced Mode 2. Enter the password accuracy to unlock the Advanced Mode. 3. Highlight the Calisto in the list. 4. Under the Calisto menu, click on Settings 5. The settings will be downloaded from the unit and the Settings window will appear

Settings Identification Adjust the date and time Enter the unit information

Settings Communication The RS485 ID is used as the monitor ID for all protocols.

Settings Oil Type Mineral Oil (ASTM3612) Voltesso 35 Technol US4000 Nytro Midel 7131 Silicone Envirotemp FR3 Luminol TRI Luminol TR Luminol BI Custom

Settings I/Os Dedicated 4-20 ma input for the Carrier Gas pressure

Settings Alarm Limits

Settings Relays

Settings - Relays Two different Fail-safe relay configurations: energized-when-always energized-when not-condition Morgan Schaffer recommends the following to establish the best levels of alarm limits and trend values: Work with the transformer manufacturer; Consult an industry expert; Carry out a statistical analysis of gas levels on a population of similar transformers being used in similar loading, environment, etc. Alarm level and relay logic should always be set with great care to maximize protection.

4. Maintenance

Maintenance The Calisto monitor is virtually maintenance free. To maximize product reliability, the following points should be verified every 6 to 12 months: 1. Install the latest firmware (if available) 2. Inspect the mounting 3. Inspect wiring, no unplugged entry holes 4. External fan is ON (for ambient > 15degC) 5. Internal fan is ON (always) 6. Verify the relay logic using Calisto Access 7. Ensure alarm limits are configured properly 8. Verify that the date and time are set properly 9. Verify that all valves are fully open 10. No material, cable, manual, etc. inside Calisto 11. Enclosure latches are tightened down 12. Inspect the oil line connections for possible leaks 13. Inspect underneath Calisto for possible leaks 14. Verify the response of the display

Maintenance Calisto 5 / Calisto 9 consumables to be replaced every 2 years: 1. Calibration gas cylinder 2. Carrier gas cylinder (helium) For more details, refer to the Calisto5/Calisto 9 Installation Manual and to the Calisto Manager User Guide.

Gas cylinder replacement Calisto 5 / Calisto 9

Starting the gas flow 1. Turn ON the monitor 2. Follow instructions on the Display (30 min.) 3. Go to Maintenance, then Combined bottle change Only open the gas cylinder shut-off valves as directed by the bottle change procedure to avoid contamination.

Installing the carrier gas cylinder Install the carrier gas adaptor onto the helium cylinder Note: You will require a large capacity 1 ½ adjustable wrench.

Installing the carrier gas cylinder Installing the high pressure carrier gas line 1. Connect the preswaged 1/8 tubing to the cylinder, tighten ¼ turn

Installing the calibration gas cylinder 1. Install the calibration gas cylinder inside the door 2. Insert one end of the cylinder in the bracket hole until captive screws become aligned with their respective nuts 3. Insert the preswaged 1/16 tubing and tighten 1/8 turn

Maintenance Most common error codes and respective solution: 1 External fan replace fan 2 Internal fan replace fan 2000 External analog input Wiring or Calisto Access 8000 No/low oil flow Verify all valves For more details, refer to the Calisto/Calisto 2 Installation and Operation Manual. Contacting Morgan Schaffer for technical support: support@morganschaffer.com +1.514.739.1967 Toll-free: 1.855.861.1967

Thank You Calisto Monitors Maintenance Presented by: Eric Thibodeau Technical Support Specialist