Zero-phase current transformer for F-MPC application. Notification of geometry change in EW Series

Similar documents
Inductive Proximity Sensor

Discharge oil capacity cm Discharge oil capacity. Max. stroke volume on retraction Remarks.

KOLMA and IHDA Indoor Type Cable Current Transformers. Catalogue. Catalogue KOLMA 1 GB Medium Voltage. ABB Transmit KKOLMA 1 GB

Three-phase isolating transformers for photovoltaic and wind-power systems

Industrial Control Transformers

IEC Standard Compliant Vacuum Circuit-Breaker (12 kv, 24 kv) for Southeast Asian Markets

Industrial Control Transformers

Marcel Fortin ing. Hydro Québec Distribution 1

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH301 WH361. Models: Contents. General Notes. Important. Description

R07 SET - 1

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. General Notes. Contents. Important MODEL: WH381 WH431 WH491

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: SH381 SH431 SH491. Contents. General Notes. Important

M Series Half-inch Rotary Switches

ESO 210 Introduction to Electrical Engineering

2014 ELECTRICAL TECHNOLOGY

EE6352-ELECTRICAL ENGINEERING AND INSTRUMENTATION UNIT I D.C. MACHINES PART A

Series 206/208 Through-Hole DIP Switch

REPLACEMENT PARTS MANUAL

Kuhlman Electric Corporation Volt Instrument Transformers

Cable current transformers for indoor applications. Product overview. Cable current transformers. for indoor applications.

PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: S38H1 W38H1 S43H1 W43H1 S49H1 W49H1 S61H1 W61H1. General Notes. Contents.

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

Starting of Induction Motors

Models: W30A2, W36A2. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

9000 Series Power Rocker and Lever Handle Switches

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

Foil Winding Machine. Description. Features

UNIT I D.C. MACHINES PART A. 3. What are factors on which hysteresis loss? It depends on magnetic flux density, frequency & volume of the material.

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W30A1, W36A1. Models: Contents. General Notes. Important.

Welcome to our company with many thanks!

FCR asynchronous brake motors LS FCR. General information

Amphenol Australia. ATM Series PRODUCT SHORTFORM. Amphenol Australia Pty Ltd. ATM Series

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Contents. General Notes. Important. Description

CPT Series Control Transformers

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE HEAT PUMPS. Models: W30H1 W36H1. Contents. General Notes. Important. Description

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

Shape - Typical designs with sector angles of pi/2 [90 degrees], and 2pi/3 [120 degrees] are shown below.

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR

Distribution transformers Efficiency over life-cycle

DC2-Wire Spatter-Guarded Cylindrical Proximity Switches

TPC TYPE N21 FEATURES. [Conformable standards] UL1059(2004) File No.E82309 EN Certificate No.B Ground terminal block

Features and Benefits

Cygnis Cy by REV LVER

ECEg439:-Electrical Machine II

Medium Voltage Metal-Enclosed Switches

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

CP Automatic capacitor bank

Medium Voltage Metal-Enclosed Switches

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

Photographs of large cities, such as Seattle, Washington, are visible reminders of how much people rely on electrical energy.

Fuji Electric. Oil immersed. Transformer FTU08A1-E-0024

Ethernet 100 Mbps Quadrax

PRODUCT CATALOG MOTORS & CONTROLS. franklinwater.com

Magnetic Contactor FJ Series and SK Series Line Expansion

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W30A1, W36A1. Models: Contents. General Notes. Important.

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Industrial Control Transformers

REPLACEMENT PARTS MANUAL

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

CAST RESIN TRANSFORMERS

REPLACEMENT PARTS MANUAL

HPS Fusion General Purpose Enclosed Transformer

PHYS 1444 Section 004. Lecture #19. DC Generator Transformer. Generalized Faraday s Law Mutual Inductance Self Inductance. Wednesday, Apr.

TABLE OF CONTENTS. Table of Contents QUALITY FEATURES 2 VARMEC NUMBERING SYSTEM 3 GEAR REDUCER SELECTION 3 REDUCER DIMENSIONS 4

Ch. 3 Magnetism and Electromagnetism

1. This question is about electrical energy and associated phenomena.

Essential Question: How can currents and magnets exert forces on each other?

Single-Phase Ventilated

Key features. DESIGNS: - Conservator type - Hermetically sealed

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution

Comfort. Description. Applications

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

Inductive Proximity Sensor

for Quadrax and ELIO 8

DC2-Wire Cylindrical Long-Distance No-Polarity Proximity Switches

Industrial Control Transformers

1000 Series Miniature Slide Switches

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

HPS EnduraCoil. Cast Resin Transformer

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

J&JK SERIES SUBMINIATURE. DCONNECTOR EMI prevention shielding cover ( J cover) J COVER. Cover nut. Cover. Dimensions mm(in.) W.

10 kw, 15φ Axial flux pancake generator for 2-blade Wind Turbine

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

REPLACEMENT PARTS MANUAL

AC/DC2-wire Type Cylindrical Proximity Switches

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

Dry Well Cannister Type CLT, OIL Immersed PTAP-AFH926. Technical Guide Load-break, Dead-break

Cylindrical Proximity Sensor E2GN

Transcription:

To All Customers Rep No. B16002 April 19, 2016 Fuji Electric FA Components & Systems Co., Ltd. Zero-phase current transformer for F-MPC application Notification of geometry change in EW Series Thank you for your continued patronage of Fuji products. We are writing to announce the changes we will be making in some products. Details are described below. Please review the following information. Please inform all related sections of your company. Product name Series and series name Zero-phase current transformer for F-MPC application EW series Type EW-Z90, EW-Z3B60, EW-Z3B80, EW-Z3B100, EW-Z4B40, EW-Z4B50, EW-Z4B60, EW-Z4B80 Changed parts Case material and dimension of geometry for ZCT section Details of the change Material is changed to epoxy mold resin from phenol resin. Geometry is also changed. See Attachments for details. (The example photograph shows EW-Z3B80) Before change After change Sections where resin material will be changed Reason for change To improve productivity. Date of production change Immediately Attachment Zero-phase current transformer Comparison Table Notes concerning the change There is no change related to performance, characteristics or wiring of the product as a result of this change. (It involves a partial change to the external appearance.) Fuji Electric FA Components & Systems Co.,

Zero-phase current transformer EW-Z90 Type for low-voltage application: Table for comparison before and after the change Type EW-Z90 Remarks Core material Permalloy (iron-nickel alloy) Inner perimeter and side shields Available Secondary coil 1,000 windings Rated frequency 50/60 Hz Rated voltage AC600 V or lower Rated current 600 A / 800 A / 1,000 A Characteristic standard Dielectric strength Operating temperature range Compatibility JIS C 8374 Residual current sensing and relaying equipment AC 2,200 V/1 min (secondary coil terminal bracket and fixing thread of attachment of exterior case, etc.) -20 to 60 Compatible with our residual current sensing and relaying equipment ZCT case Phenol resin Epoxy mold resin Both are thermosetting resin Outer dimension (mm) Based on P2/5 Based on P2/5 Compatibility in terms of attachment is available The product after change is totally compatible with the product before change in terms of characteristics, outer size, pitch for attachment and so forth. FIN759312 1 / 5

Type EW-Z90 Photograph showing appearance Dimension drawing Test terminal Output terminal FIN759312 2 / 5

Zero-phase current transformer EW-Z3B60,80,100, EW-Z4B40,50,60 and 80 Types with copper belt for low-voltage application: Table for comparison before and after the change Type EW-Z3B60,80,100, EW-Z4B40,50,60,80 Remarks Core material Permalloy (iron-nickel alloy) Inner perimeter and side shields Available Secondary coil 1,000 windings Rated frequency 50/60 Hz Rated voltage AC600 V or lower Rated current Characteristic standard Dielectric strength Operating temperature range Compatibility 3 phases: 600 A / 800 A / 1,000 A 4 phases: 400 A / 500 A / 600 A / 800 A JIS C 8374 Residual current sensing and relaying equipment AC 2,200 V/1 min (secondary coil terminal bracket and fixing thread of attachment of exterior case, etc.) -20 to 60 Compatible with our residual current sensing and relaying equipment ZCT case Phenol resin Epoxy mold resin Both are thermosetting resin Outer dimension (mm) Based on P4/5 Based on P4/5 Compatibility in terms of attachment is available This product after change is totally compatible with the product before change in terms of characteristics, outer size, pitch for attachment, copper belt size, copper belt connection position and so forth. FIN759312 3 / 5

Type EW-Z3B60,80,100, EW-Z4B40, 50, 60 and 80 Product before change Product after change 3-pole t dimension 600 A: 6 mm 800 A: 8 mm 1,000 A: 12 mm 400 A: 5 mm 500 A: 6 mm t dimension 600 A: 6 mm 800 A: 8 mm 1,000 A: 12 mm 400 A: 5 mm 500 A: 6 mm 4-pole 400, 500 A connection hole, one on each side) (400, 500 A connection hole, one on each side) Side-view (Common for 3-pole and 4-pole) Value in parentheses indicates the value for 400 and 500 A items. Value in parentheses indicates the value for 400 and 500 A items. FIN759312 4 / 5

photograph showing appearance (example) EW-Z3B60,80 and 100 The example photograph shows EW-Z3B80 The example photograph shows EW-Z3B80 FIN759312 5 / 5