Installation Manual. RW240/400/600 Motor Gearbox

Similar documents
L I N E A R A C T U AT O R

Product features & Overview. KA Linear actuators

Ridder LogicDrive. The logical solution for intensive livestock farming and crop storage. drive to innovate

YG101 SWING GATE OPENER OWNER S MANUAL

Instruction Manual. Q Series 2 Motor Control Modules - OEM

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

Linear actuator. Product features. Overview. Wide range of force outputs. Wide selection of column adapters. Wide selection of flanges

COOKSON OWNER S MANUAL

Product features & Overview. N1 - N4 A Rotary and part-turn actuators

Ridder Equipment. Our commitment to you... Tel Fax:

ELECTRONIC CONTROL ACTUATOR

SPARE PART LIST POWER LIFTKET

Transmission systems: Multiple components that have the same type of movement (rotational, linear, etc)

Ordering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend:

Mounting and Operating Instructions EB 5868/5869 EN

SKF Flex Coupling Installation Instructions

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Power consumption In operation At rest For wire sizing

CVR-625. Compact Vibrating Rod Instruction Manual

RF Point Level Control with Sensor Monitor

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Operating instructions for worm gear boxes

Metal Clad Air Insulated Switchgear

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

Installation, Operating & Maintenance Instructions

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Zone 1 Linear Range - Installation Guide

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

DIAMOND POINT VIBRATING PROBES

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

Q u a r t e r T u r n E l e c t r i c A c t u a t o r s

Motor-drive mechanism, type BUL. Technical guide

Air damper actuators

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Vertical Linear Drive with Toothed Belt and Integrated Recirculating Ball Bearing Guide Series OSP-E..BV

Air damper actuators

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

SKC400U SLIDING GATE OPENER OWNER S MANUAL

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

FSAF24(-S) US, FSAF120(-S) US

Operations Manual. Zero Speed Switch Sensor Model ZS09P

SMC BATTERY CHARGER USER S MANUAL SMC USER S MANUAL

Toothed belt axis ELGC-TB-KF. Operating instruction [ ]

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

GDB..3..1A GLB..3..1A

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

CHAPTER 2: ELECTRICAL SAFETY

I N S TA L L AT I O N G U I D E

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Vertical Linear Drive with Toothed Belt and Integrated Recirculating Ball Bearing Guide Series OSP-E..BV

IQL Helios Area-/Streetlight. User Manual

Manufacturing & Service: Bierer & Associates Inc. Patent No. 6,885,180. ST Series Service Tester Phase Identifier Operating Instructions ST500PGN

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

I N S TA L L AT I O N G U I D E

Vertical Linear Drive with Toothed Belt and Integrated Recirculating Ball Bearing Guide Series OSP-E..BV

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Exchange of rollers from the XTS-Mover

Linear Valve Electric Actuator

1.Safe testing IMPORTANT:

DATA PD SV13.., SV14.. Levelling Valves. Product. Function. Technical Features. Range Overview

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Installation Instructions

I N S TA L L AT I O N G U I D E

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified

Nuova CEVA Automation. Via G.B. Signini 43. Briga Novarese (NO) ITALY Tel Fax

Differential Pressure Transmitter

PULSE-8: MASTER PULSATION CONTROL

I N S TA L L AT I O N G U I D E

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

AF Series Spring Return Direct Coupled Actuator

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

Assembly and Operating Instructions

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

VIS IRREVERSIBLE ELECTROMECHANICAL MOTOR FOR SECTIONAL DOORS. Rev /2011 RT

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Twin Power. Manual. Pneumatic Multiturn actuator in Standard and ATEX design WARNING! WARNING! Mounting. Assembly example

HIGH SPEED SLIDING GATE OPENER

User manual for. Exalto windshield wiper Type 223 BD 12/24 Volt

HAZARDOUS (NEMA 7/9) INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR 2 YEAR WARRANTY. Serial # Box. Installation Date. Wiring Type

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

Phoenix Inverter

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

AA4006 Speed Sensitive Trip Unit. User Manual

Ridder Equipment. Our commitment to you... Tel Fax:

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

Transcription:

Installation Manual RW240/400/600 Motor Gearbox Ridder Drive Systems Lorentzstraat 36-38 C 3846 AX Harderwijk P.O. Box 360 C 3840 AJ Harderwijk The Netherlands T +31 (0)341 416 854 C F +31 (0)341 416 611 E info@ridder.com C I www.ridder.com 265050GB - 201005

Index Installation manual for RW240/400/600 motor gearboxes................................. 2 Warnings in this installation manual... 2 Ridder RW240/400/600 motor gearboxes............................................. 3 Mounting of RW240/400/600 motor gearbox........................................... 4 Breather plug RW240/400/600 motor gearbox with oil lubricant............................ 4 Mounting positions RW240/400/600 motor gearbox with oil lubricant....................... 5 Mounting positions RW240/400/600 motor gearbox with grease lubricant.................... 6 Junction diagram symbols......................................................... 7 Junction diagram RW240/400/600 motor gearbox: 3-phase............................... 8 Junction diagram RW240/400/600 motor gearbox: 1-phase (3-wire)........................ 9 Junction diagram RW240/400/600 motor gearbox: 1-phase (5-wire)....................... 10 Adjustment RSU limit switch system................................................ 11 Directions of rotation RW240/400/600 motor gearboxes................................. 12 Installation manual RW240/400/600 motor gearbox This installation manual for the Ridder RW240/400/600 motor gearboxes contains basic information for the mechanical and electrical installer. Read this installation manual before installing a Ridder RW240/400/600 motor gearbox. All installation handlings must be carried out safely and correctly by qualified and competent mechanical and electrical installers. Warnings in this installation manual This manual contains tips, observations and warnings. They are divided into a number of gradations. The following shows an overview and description of the meaning of the tip, observation or warning. TIP A suggestion or advice in respect of carrying out an operation. WARNING CAUTION Remarks and extra information regarding potential problems arising when an operation is carried out incorrectly. The product or system can be at risk when an operation is carried out incorrectly. DANGER The user, installer or other persons could suffer physical and/or life threatening injury when an operation is carried out incorrectly. 2

Ridder RW240/400/600 motor gearboxes The RW240/400/600 motor gearboxes are maintenance-free, compact power units for driving ventilation, screening and lifting systems in greenhouses and livestock sheds. All RW240/400/600 motor gearboxes feature a self-braking worm gear transmission. This transmission ensures that the output shaft is braked when the drive unit is stopped. The combination of carefully matched pinion and worm reductions results in a very quiet mechanical transmission. The RW240/400/600 motor gearboxes feature a patented integrated linear limit switch system with duty and safety switches having excellent switching precision. The maximum switching range of the limit switch system equates to 86 revolutions of the drive shaft. By using a potentiometer with the optional built-in set, it is possible to precisely feed back the positions of a drive system to a (climate) computer. The RW240/400/600 motor gearboxes are standard finished with a graphite grey powder coating and are supplied including fixing bolts and spring washers. RW240/400/600 Motor gearboxes: Drive torques of 240Nm, 400Nm or 600Nm at 50 Hz and 60 Hz mains frequencies; Rotation speeds of 1 to 5 rpm at 50 HZ, 1.2 to 6 rpm at 60 HZ mains frequency; Suitable for intermittent duty, duty class s3-30%, duty cycle maximum 25 minutes; Fitted with 16-tooth 5/8 x3/8 zinc-plated sprocket for chain couplings; Manual drive enabled by means of a hexagon socket in the electric motor shaft; Electric motors are standard tropic-proof and conform to protection class IP55; Electric motors for RW240/400/600 motor gearboxes: 3-phase euro voltage for use on main voltages of 400V at 50Hz and 480V at 60Hz; 3-phase wide voltage electric motors with UL (recognized) and CSA approval mark, for use on mains voltages from 208-415 V at 50 Hz and 60 Hz and 415-480 V at 60 Hz; 3-phase electric motors with CSA approval mark, for use on mains voltage of 600 V at 60 Hz; 1-phase electric motors for use on mains voltage of 230 V at 50 Hz and 60 Hz; 1-phase electric motors with CSA approval mark, for use on mains voltage from 115 V at 60 Hz. CAUTION DANGER Do not exceed the maximum duty cycle Do not use the Ridder RW240/400/600 motor gearboxes for transporting / lifting people DANGER Disconnect the power supply when working on or maintaining a RW240/400/600 motor gearbox or the system driven 3

Mounting of RW240/400/600 motor gearbox The RW240/400/600 motor gearboxes (with oil or grease lubricant) may only be mounted according to the described mounting positions. Make use of the three (3) supplied bolds M10x22 for mounting a RW240 or RW400 or RW600 motor gearbox to a structure (mounting plate). Make sure that the structure (mounting plate) is definitely strong enough for handling the forces and drive torques of the RW240 or RW400 or RW600 motor gearbox. Breather plug RW240/400/600 motor gearbox with oil lubricant After mounting of a RW240/400/600 motor gearbox with oil lubricant (oliegevuld), the upmost oil plug has to be replaced by the supplied oil breather plug. CAUTION Mounting the motor gearbox without the breather plug could lead to oil leakage 4

Mounting positions RW240/400/600 motor gearbox with oil lubricant 90 150 30 0 α 30 150 α 180 180 α=0 30 < α < 150 180 < α < 360 270 90 150 30 0 α 30 180 150 α 180 30 < α < 150 180 < α < 360 α=0 270 Ridder Drive Systems C T +31 (0)341 416 854 C 5 F +31 (0)341 416 611 C I www.ridder.com

Mounting positions RW240/400/600 motor gearbox with grease lubricant 90 α=0 0 α 360 180 270 90 0 α 180 315 α 360 α=0 180 < α < 315 180 315 270 Ridder Drive Systems C T +31 (0)341 416 854 C 6 F +31 (0)341 416 611 C I www.ridder.com

Junction diagram symbols Symbol Description EM Electric motor ES11, ES12 Working switch limit switch system ES21, ES22 Safety switch limit switch system F1 Fuse K11 Safety relays K21, K22 Direction switching relays L1, L2, L3 Power lines, power supply N Neutral P21, P22 Electrical interlock P71, P72 Automatic control PE Earth Q41 Motor safety switch S11 Manual switch (emergency switch override) S111 Manual switch U1 Transformer CAUTION Observe 2 seconds time delay before switching direction of rotation CAUTION Parallel connecting of single phase electric motors is not allowed! 7

Junction diagram RW240/400/600 motor gearbox: 3-phase 45 ma - 130 ma (24V-AC) TIP Changing the direction of rotation electric motor: Swap L1 and L2 Change switching direction of limit switch system: Swap 1 and 7 8

Junction diagram RW240/400/600 motor gearbox: 1-phase (3-wire) 45 ma - 130 ma (24V-AC) TIP Changing the direction of rotation electric motor: Swap V1 and W1 Change switching direction of limit switch system: Swap 1 and 7 9

Junction diagram RW240/400/600 motor gearbox: 1-phase (5-wire) 45 ma - 130 ma (24V-AC) TIP Changing the direction of rotation electric motor: Swap V1 and W2 Change switching direction of limit switch system: Swap 1 and 7 10

Adjustment RSU limit switch system RSU limit switch system installation The steps required in order to correctly set the RSU limit switch system of an RW240/400/600 motor gearbox, are described below. Current and voltage range The contacts in the switches of the Ridder RSU limit switch system, are capable of switching the following currents: 24 V-AC, currents from 45 ma to 130 ma; 230 V, currents up to 1 A. Ridder RSU limit switch system The Ridder RSU limit switch system is a linear switch system, specifically designed for use in the RW motor gearboxes. The limit switch system is driven by the output shaft of the motor gearbox, via a secondary transmission. Depending on the type of motor gearbox, a number of revolutions of the output shaft can be set, between a starting and ending position. For the RW240/400/600 motor gearboxes this will be a maximum of 86 revolutions of the output shaft. Delivery A Ridder motor gearbox with RSU limit switch system is delivered with switch followers (4) whose adjustment rings (3) still have to be fastened. This means that the drive can turn freely in both directions. This also avoids the possibility of causing damage to the limit switch system (when it has not yet been connected), should any (preset) limiting positions be exceeded during electrical or manual operation of the motor. How it works This transmission drives the threaded shaft (1) of the Ridder RSU limit switch system, either with a toothed belt, or with a worm and gear combination. When running, the threaded switch followers (4) will move along the threaded shaft as it rotates. One setscrew (a) rests against the switch spring (6). When an end position is reached, the switch follower will strike the stop (7) and will then rotate with the threaded shaft. This deflects the switch spring, and a duty switch (ES11 or ES12) will be tripped. This causes a signal that activates the relay, stopping the motor gearbox. Should a relay or duty switch fail, then a safety switch (ES21 or ES22) will also be tripped by the switch spring. This causes a signal that activates a safety relay, stopping the controller and also thereby the motor gearbox. This prevents consequential damage to the driven system. 11

Connection When connecting the Ridder RSU limit switch system, please refer to the wiring diagrams provided for this purpose. Setting The start position and end position are set as follows: By rotating the output shaft (manually or under power), bring the system to the start position or end position and determine which duty switch (ES11 or ES12) should be tripped. The switching sense of the RSU limit switch system can be reversed by swapping connections 1 and 7 in the connection block. Turn the milled bush (2) on the appropriate side, hand tight up to the stop (7). The milled bush can easily be screwed by hand along the threaded shaft (1). The switch follower (4) also moves along the threaded shaft. Now rotate the adjustment ring (3) over the milled nut just far enough to trip the duty switch. Then fasten the adjustment ring with setscrews (a and b) firmly on the milled nut. The adjustment ring can no longer be rotated over the milled nut. Repeat previous items to adjust the limit switch system for the opposite rotation direction. This completes the setting of the limit switch system. WARNING CAUTION Always check the functioning of the limit switch system after setting up both end positions. When a motor gearbox with an adjusted limit switch system is operated manually, do not exceed the set up end positions. This can lead to mail functioning of the limit switch system and serious damage to the system driven. Directions of rotation RW240/400/600 motor gearboxes B B A A B A B A 12