M-23A, M-23B, M-3 and Low-Profile M-3 Electric Switch Machines

Similar documents
M-23A, M-23B, M-3 and Low-Clearance M-3 Switch Machines with MCC

M-23A, M-23B and M-3 Switch Machines with MCC and Independent Point Detection

Tools for Switch Machines, Switch Layout Hardware and Related Equipment

HC-120B Flashing Light Units and Assemblies

QUALITY PLEDGE WE, THE EMPLOYEES OF J&A INDUSTRIES, LLC AFFIRM OUR COMMITMENT TO EXCELLENCE. OUR PLEDGE TO PROVIDE THE HIGHEST QUALITY

Electropneumatic Timing Relays Series 7000 Industrial

Bolted contact switches. Pringle switches

SECTION ELECTRIC MOTOR ACTUATORS FOR VALVES

E Series Electric Actuators

S&C Switch Operators Types AS-1A and AS-10

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

ADJUSTMENT AND TESTING

Horizontal Circuit Switchers

Horizontal Circuit Switchers

SECTION MOTOR CONTROL

How to Select the RE Industrial Actuator Part Number

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

SERIES 1000 ELECTRIC ACTUATORS

MC-351, 421, 431, MC-4311

Starting Systems & Traction Motor Systems. ATASA 5 th. ATASA 5 TH Study Guide Chapter 18 Pages Starting & Traction Motor Systems 62 Points

SPECIAL SPECIFICATION 6894 Communication Cabinet

T57 SERIES LOW ENERGY OPERATOR INTRODUCTION FEATURES BENEFITS PATENTS TABLE OF CONTENTS

SPECIAL SPECIFICATION 1788 Surveillance Cabinet

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE

PLK/PLKD SERIES PLK/PLKD PIN LOCATING CLAMPS

ACCUTECT Lightning Protection Networks

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

GRB. long life Compact Angular gripper SHIPS IN 1-2 days. Major Benefits. Industry Uses

Stelron PS Indexer. PS Series Parallel Shaft Indexer

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

IN2 Enclosed Switches and Circuit Breakers

SKC400U SLIDING GATE OPENER OWNER S MANUAL

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

pg. 2 Using Sensing Edges in Safety Applications How sensing edges work Understanding the fail-safe concept

Subarc DC Series. Processes Submerged Arc (SAW) Stick (SMAW) Air Carbon Arc Cutting and Gouging (CAC-A) Subarc DC 650 shown.

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS

7100SZ SERIES. Multi-Point Closer/Holder with Motion Sensor

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

TEL: G&C Electronics CC E. T.

Self-Adjusting Two-Wire Hall Effect Gear Tooth Sensor IC CYGTS9804

Series Electric Actuators

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

Crane Control Class 6131

Linear actuator. Product features. Overview. Wide range of force outputs. Wide selection of column adapters. Wide selection of flanges

Installation Instructions

2000 Series Geared Rotary Limit Switches

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

KEANE MONROE a member of the record group

Multi-Pak Group Control

Automation Selection Guide

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

Apartment Complex/Gated Communities Mixed Use Buildings Commercial/Industrial Parking Self Storage Maximum Security

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N

MAX-E1 HIGH EFFICIENCY. Severe Duty

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

Installation Instructions

Specifications. S&C Switch Operators Types AS-1A and AS-10a. Conditions of Sale

DUAL-END DRIVE JOURNALTRUING AND AXLE LATHES ~ FARREL COMPANY, DIVISION OF USM CORPORATION, ROCHESTER, N.Y.

ELECTRICAL SYSTEM RP-7

Multi-point closer/holder with motion sensor 7100SZ DOOR CLOSER CATALOG

the Interactive Catalog

Position Transmitters. Instruction Manual. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

INSTALLATION MANUAL AP60B INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Ideal for part clamping in weld areas

10260 Retrofit to 10260A Non-Contact Sensor Instructions Kits through -512

DORMA Automatics, Inc. 924 Sherwood Drive Lake Bluff, Illinois U.S.A. Toll Free: Fax:

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

TS93 EMF T/PT/TDE. Surface applied door closer

DMC mA Positioner

Actol Electric Quarter-turn Valve Actuators

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Please make your selections below to view, search or print ACCO Material Handling Solutions WRIGHT SPEEDWAY and WRIGHT WORK-RATED product pages.

POSITION TRANSMITTERS

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Level Crossing Solutions

In-Line Positive Feed Tools

Product features & Overview. KA Linear actuators

V4(V7)-ABFW-EPN16 Actuated Wafer type butterfly valves

2006 Series Geared Rotary Limit Switches

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

Type EB, EBB, EBF and VEB DOUBLE SIDE BREAK SWITCHES 38 kv through 362 kv 600 to 3000 Ampere

5700 SERIES Low Energy Power Operator

Silvertel. 1. Features. 2. Description. IEEE802.3at compliant. Maximum 30 Watt Output Power. High efficiency DC/DC converter

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

Installation Instructions

Electromotoric Actuators

VG7000 Series Bronze Control Valves

ADAMS RITE. ADAMS RITE MANUFACTURING COMPANY Sliding Hardware/Exit Devices Series Turns

Screw jacks MA Series

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

7100SZ Series SafeZone Installation and Instruction Manual

Transcription:

Switch Machines and Associated Equipment Ansaldo STS USA M-23A, M-23B, M-3 and Low-Profile M-3 Electric Switch Machines ASTS USA s style M Electric Switch Machines are rugged, reliable, units designed for any installation where electric power is available. The M-23A and M-23B units have dual control features, including a hand-throw lever to permit operation by on-site trainmen or maintainers, as well as by remote controlled power. The standard and Low-Profile M-3 Switch Machines are recommended for applications where there is seldom a need to manually operate the switch. These three machines are available with a variety of operating speeds, gear ratios and motor voltages. Numerous circuit controller configurations are also available, both mechanical and electronic. Table of Contents General Description... 1 M-23A and M-23B Machines with MCC*... 3 M-23A and M-23B Machines with ECC* and MCU*... 7 M-23A and M-23B Machines with IPD*... 9 M-3 Switch Machine with MCC*... 10 M-3 Machines with ECC and EBNC*... 13 M-3 Machines with IPD*... 14 Low-Profile M-3 Machines... 15 * MCC = Mechanical Circuit Controller ECC = Electronic Circuit Controller MCU = Motor Control Unit IPD = Inpendent Point Detection EBNC = Electronic Biased Neutral Controller General Description Key Options Style M Electric Switch Machines are available with a numerous features and options to suit customer needs. These include various operating voltages, gear ratios, throw times and control wiring schemes as shown in the ordering tabulations. Basic differences include the following: M-23A and M-23B with: Mechanical circuit controller. Electronic Circuit Controller (ECC) and Motor Control Unit (MCU) With independent point detection Without independent point detection General Description (cont d) M-3 with: Mechanical circuit controller for general installations. ECC and Electronic Biased Neutral Controller (EBNC) With independent point detection Without independent point detection Low-Profile M-3 with: Mechanical circuit controller. Without independent point detection Refer to the ordering tabulations to determine which of the above options are available in which combinations, or are stand-alone options. Basic Design Style M Electric Switch Machines consist of a motor, a gear train, a cam arrangement (for operating the switch and locking) and a circuit controller. All of these machines use the same basic casting, and are interchangeable with respect to mounting and connections in a switch layout. However, the M-23A and M-23B machines require a somewhat higher clearance than the standard M-3 or Low Profile M-3. Both models of the M-3 Switch Machine can be operated by hand by inserting a temporary crank. For installations where extra vertical clearance is needed, the Low Profile M-3 Electric Switch Machine is recommended. This machine is similar to the standard M-3 in design and operation, but is 5/8-inch (1.58 cm) lower in vertical dimension. This small but important height reduction makes the Low Profile M-3 ideal for third-rail transit applications where additional clearance is needed for the vehicle pick-up shoe. The point detector bar can be To order, call 1-800-652-7276 e-mail: orders@ansaldo-sts.us www.ansaldo-sts.com, p. 1

Ansaldo STS USA General Description (cont d) vertically lifted from the machine, allowing easy handling in tight confines. Left and right-hand versions of this machines are available, each with a single operating voltage, gear ratio and wire control scheme. The M-23A uses a different hand-throw pinion than the M- 23B, which affects hand-throw locking. Power operation is the same with both machines. In the M-23A, the hand throw lever gives the same mechanism stroke and full lock rod protection as the power operated mode. In the M-23B, however, the lever does not provide lock-rod protection (slide bar and lock box do not move full stroke). All M style machines are wired at the factory, with internal wiring connected to a main terminal board in the motor compartment. A typical wiring diagram or working drawing is enclosed with each shipped machine to show how external connections should be made to the main terminal board for a particular application. Motor and Gear Train ASTS USA M Electric Switch Machines use a fully enclosed, permanent magnet motor. This type of motor provides lower inductance, better EMI immunity and higher efficiency than previous field wound motors, and incorporates simpler 3-wire control. (Permanent magnet motors are also available for retrofitting older models of these switch machines; see RSE-6A4.) The gear train in the M style Switch Machines is comprised of a pinion on the end of the motor shaft, one or two reduction gears, clutch gear, friction clutch, worm shaft and worm gear. Three different gear ratios are used to provide three operating speeds: 189:1, 360:1 and 528:1. The Low Profile M-3 incorporates the same basic gear train concept as the other style M machines, and is provided with a single gear ratio of 189:1. In all style M machines, a friction clutch protects the mechanism from the shock incurred at the end of a stroke, or when an obstruction is present. For complete motor and gear train specifications, refer to the ordering tabulations. Mechanical Circuit Controller The mechanical Circuit Controller used in the style M switch machines has four pairs of contacts. Two motor control contacts are wired internally. The remaining are indication contacts for external switch position determination. To allow standardized wiring, provision is made to always have certain contacts set as normal, regardless of which end of the operating stroke is designated as normal. Machines equipped with an mechanical circuit controller include a point detector with latch device. A latchout kit is available for the point detector mechanism (see RSE-6A4). Components in this kit enable the circuit controller indication contacts to be held open (until reset) when the point detector bar is displaced while the machine is in locked-up condition (i.e. switch points obstruction). M-23A, M-23B, M-3 and Low-Profile ECC+EBNC or ECC+MCU ASTS USA offers models of its standard M-3, M-23A and M- 23B switch machines outfitted with an Electronic Circuit Controller (ECC), in conjunction with an Electronic Biased Neutral Controller (EBNC) or Motor Control Unit (MCU). A true linear detection device with no moving mechanical parts to maintain, the ECC eliminates circuit-controller sensitivity degradation due to component wear. The ECC utilizes inductive proximity sensors to continuously monitor switchmachine conditions. It vitally monitors the position of the switch points and the internal locking mechanism, delivering switch-machine indications to the wayside. For more information on this device, refer to RSE-6F3. ASTS USA can also add the ECC unit into existing machines returned to the factory for refurbishment; refer to the RSE catalog introduction for more information on this service, or contact your ASTS USA Account Executive. The EBNC is used in the M-3 machines with ECC to enable direct control of the switch machine using a bipolar output of a vital logic controller such as the MicroLok II or the MicroLok Object Controller. In an EBNC-equipped machine, the motor power is fed from a fixed polarity source (direction determined by the EBNC). In the M-23A and M- 23B machines with an MCU, motor power is fed from a bipolar source (direction determined by the wayside control equipment). The M-3 s EBNC includes a motor overload protection function. Overload protection for the M-23A/B s MCU is provided by the wayside control equipment. Existing installations using 3- or 5-wire control are converted to 2- wire control when installing an M-3 ECC/EBNC or M-23A/B ECC/MCU machine. Independent Point Detection (IDP) Selected models of the M-3, M-23A and M-23B switch machines (with mechanical circuit controller) are equipped to provide independent point detection. With this feature, the point detection mechanism senses the position of the near and far switch machine points independently to ensure that both are in the proper relative positions to each other and the rails. Thus, any mounting problems or unwanted slack in the connecting rod between the points are detected. (In other switch machines, only the nearest switch point movement is monitored). M-3 Machines for Replacement of Alstom Machines with 2- Wire Control Four versions of the M-3 Switch Machine with mechanical circuit controller can be used to replace selected Alstom with 2-wire control. Refer to ordering tabulation on page 12 for specific part numbers. Contact your ASTS USA Account Executive or request Service Manual SM-6263 for additional information., p. 2

M-23A, M-23B, M-3 and Low-Profile Ansaldo STS USA M-23A and M-23B Machines with Mechanical Circuit Controller: Specifications and Ordering Information Specifications Weight: Dimen. (Overall): Motor Type: Motor Voltages: Motor RPM: Operating Times*: Clutch Settings: Control Ckt. Wiring: 860 lbs. (390 kg) 63.5 L x 33 W x 14 H (161.3 cm L x 83.8 cm W x 35.6 cm H) Fully enclosed perm. magnet type 20 Vdc or 110 Vdc (see tabs.) 500 RPM for 528:1 geared mach. 650 RPM for 360:1 geared mach. 1450 RPM for 189:1 geared mach. 4.5, 15.0, or 26.0 sec. (see tabs.) (*Per AREMA standards. Times will vary depending upon actual operating conditions.) 14A for 189:1 geared machines 23A for 360:1 geared machines 12A for 528:1 geared machines 3-wire or 5-wire (see ordering tabs.) Ordering Information To order M-23A or M-23B switch machines with mechanical circuit controllers: Refer to Configuration Guide on page 4. Guide gives all available design and operating options, each denotes with a letter. Go to ordering tabs. and select desired options. Also select machine according to desired motor voltage, operating speed and gear ratio. Ordering Information (cont d) Refer to RSE-6A4 for the following support equipment: Permanent magnet retrofit motor kits for old style M- 23A and M-23B machines. Latchout kit. Latch stand. Point detector bars Lock rods and lock connecting rods Refer to RSE-6F3 to order retrofit Electronic Circuit Controller (ECC) for style M machines with mechanical circuit controllers. Refer to RSE-6F4 to order retrofit Electronic Biased Neutral Controller (EBNC) for M-23A and M-23B switch machines. Refer to RSE-6J1 for tools (switch layout and shop maintenance) used to maintain style M machines. If ordering M-23A or M-23B machines for a new switch layout, please supply all required specifications, and mounting dimensions according to approved track plans (contact your ASTS USA Account Executive for any assistance needed). Request ASTS USA Service Manual SM-6263 for M-23A and M-23B switch machine replacement parts. Configuration Guide for M-23A and M-23B Switch Machines with Mechanical Circuit Controller A 15W, 230V Heater in Circuit Controller B 15W, 230V Heater for Motor C 15W, 115V Heater in Circuit Controller D 15W, 115V Heater for Motor E 15W, 115/230V Heater in Circuit Controller F 15W, 115/230V Heater for Motor G 15W, 24V Heater in Circuit Controller H 15W, 24V Heater for Motor J Lock Rod Openings Closed K Provided without Main Terminal Board L Uses Harness N320067 (Flag Type Terminals) M Uses Harness N320069 (Flag Type Terminals) N Uses Circuit Controller without Point. Detector Latch O Clutch Set at 14 Amperes P Clutch Set at 10 Amperes Q Assembled without Latch for Retaining Machine in the Off-Power Position when Hand Crank Cover is Open (continued on next page.), p. 3

Ansaldo STS USA M-23A, M-23B, M-3 and Low-Profile M-23A and M-23B Machines with Mechanical Circuit Controller: Specifications and Ordering Information Configuration Guide for M-23A and M-23B Switch Machines with Mechanical Circuit Controller R (Not applicable to M-23A and M-23B machines.) R (M23A) Ventilators Furnished in the Circuit Controller R (M23B) With (1) Can Of Lubricant. S (Not applicable to M-23A and M-23B machines.) S (M23A) Telephone Jack in Circuit Controller T 15w, 115v Heater for Motor. U (Not applicable to M-23A and M-23B machines.) U (M23A) V V (M23A) W W (M23A) X X (M23A) Y (M23A) Includes 1 Can of Lubricant (Not applicable to M-23A and M-23B machines.) Heater On/Off Switch in Motor (Not applicable to M-23A and M-23B machines.) Short Circuiting Strip (Shunt Bar) Installed (Not applicable to M-23A and M-23B machines.) Wiring Harness Is Suitable for 3 or 5 Wire Control Circuit Controller without Self-Restoring Latchout Block M-23A Switch Machines with Mechanical Circuit Controller Motor Gear Speed Control Order No. Layout Options (Vdc) Ratio (Sec.) Circuit Wiring N451160-0501 Left-Hand -- 20 360:1 15.0 5-Wire N451160-0502 Right-Hand -- 20 360:1 15.0 5-Wire N451160-0503 Right-Hand -- 20 528:1 26.0 5-Wire N451160-0504 Right-Hand K, O, U 20 528:1 26.0 3-Wire N451160-0505 Left-Hand K, O, U 20 528:1 26.0 3-Wire N451160-0506 Left-Hand -- 20 528:1 26.0 5-Wire N451160-0507 Right-Hand -- 20 360:1 15.0 5-Wire N451160-0508 Left-Hand -- 20 360:1 15.0 5-Wire N451160-0509 Left-Hand C, D 20 360:1 15.0 5-Wire N451160-0510 Right-Hand C, D 110 189:1 4.5 5-Wire N451160-0511 Left-Hand C, D 110 189:1 4.5 5-Wire N451160-0512 Right-Hand N 20 528:1 26.0 5-Wire N451160-0513 Left-Hand N 20 528:1 26.0 5-Wire N451160-0514 Right-Hand U 110 189:1 4.5 5-Wire N451160-0515 Right-Hand A, B 20 528:1 26.0 5-Wire N451160-0516 Left-Hand A, B 20 528:1 26.0 5-Wire N451160-0517 Left-Hand -- 20 528:1 26.0 5-Wire N451160-0518 Right-Hand -- 20 528:1 26.0 5-Wire N451160-0519 Left-Hand R 110 189:1 4.5 5-Wire N451160-0520 Right-Hand R 110 189:1 4.5 5-Wire N451160-0521 Right-Hand C, D, R 20 528:1 26.0 5-Wire N451160-0522 Left-Hand C, D, R 20 528:1 26.0 5-Wire N451160-0523 Right-Hand C, D, S, T 110 189:1 4.5 3-Wire N451160-0524 Left-Hand C, D, S, T 110 189:1 4.5 3-Wire N451160-0525 Right-Hand G, H, S 20 360:1 15.0 5-Wire N451160-0526 Left-Hand G, H, S 20 360:1 15.0 5-Wire N451160-0527 Right-Hand C, D, V 110 189:1 4.5 5-Wire N451160-0528 Left-Hand C, D, V 110 189:1 4.5 5-Wire N451160-0529 Right-Hand C, D, S, T 110 189:1 4.5 3-Wire N451160-0530 Left-Hand C, D, S, T 110 189:1 4.5 3-Wire N451160-0531 Right-Hand G, H, S 20 360:1 15.0 3-Wire N451160-0532 Left-Hand G, H, S 20 360:1 15.0 3-Wire N451160-0533 Right-Hand N 20 528:1 26.0 5-Wire N451160-0534 Left-Hand N 20 528:1 26.0 5-Wire N451160-0535 Right-Hand O, R 110 189:1 4.5 3-Wire N451160-0536 Left-Hand O, R 110 189:1 4.5 3-Wire (Tabulation continued on following page.), p. 4

M-23A, M-23B, M-3 and Low-Profile Ansaldo STS USA M-23A and M-23B Machines with Mechanical Circuit Controller: Specifications and Ordering Information (Tabulation continued from previous page.) M-23A Switch Machines with Mechanical Circuit Controller Motor Gear Speed Control Order No. Layout Options (Vdc) Ratio (Sec.) Circuit Wiring N451160-0537 Right-Hand N, W 20 528:1 26.0 3-Wire N451160-0538 Left-Hand N, W 20 528:1 26.0 3-Wire N451160-0539 Left-Hand G, H 110 189:1 4.5 3-Wire N451160-0540 Right-Hand G, H 110 189:1 4.5 3-Wire N451160-0541 Right-Hand G, H 110 189:1 4.5 3-Wire N451160-0542 Left-Hand G, H 110 189:1 4.5 3-Wire N451160-0543 Left-Hand U 110 189:1 4.5 5-Wire N451160-0544 Left-Hand N, W 110 189:1 4.5 3-Wire N451160-0545 Right-Hand N, W 110 189:1 4.5 3-Wire N451160-1201 Right-Hand C, D, J 110 189:1 4.5 3-Wire N451160-1202 Left-Hand C, D, J 110 189:1 4.5 3-Wire N451160-1203 Left-Hand -- 110 189:1 4.5 3-Wire N451160-1204 Right-Hand C, D 110 189:1 4.5 3-Wire N451160-1205 Left-Hand C, D 110 189:1 4.5 3-Wire N451160-1206 Right-Hand C, D 20 528:1 26.0 3-Wire N451160-1207 Left-Hand C, D 20 528:1 26.0 3-Wire N451160-1208 Left-Hand -- 110 189:1 4.5 5-Wire N451160-1209 Left-Hand N, W 20 528:1 26.0 5-Wire N451160-1210 Right-Hand N, W 20 528:1 26.0 5-Wire N451160-1211 Left-Hand C, D, V 110 189:1 4.5 3-Wire N451160-1212 Right-Hand C, D, V 110 189:1 4.5 3-Wire N451160-1213 Right-Hand E, Q, W 20 528:1 26.0 3-Wire N451160-1214 Left-Hand E, Q, W 20 528:1 26.0 3-Wire N451160-1215 Right-Hand C, D 110 360:1 8.0 3-Wire N451160-1216 Left-Hand C, D 110 360:1 8.0 3-Wire N451160-1217 Right-Hand W, X, Y 20 528:1 26.0 3-Wire N451160-1218 Left-Hand W, X, Y 20 528:1 26.0 3-Wire N451160-1219 Right-Hand C, D, X 110 189:1 4.5 3-Wire N451160-1220 Left-Hand C, D, X 110 189:1 4.5 3-Wire N451160-1221 Left-Hand C, D 110 189:1 4.5 3-Wire N451160-1222 Right-Hand C, D 110 189:1 4.5 3-Wire N451160-1223 Left-Hand -- 20 528:1 26.0 3-Wire N451160-1224 Right-Hand -- 20 528:1 26.0 3-Wire N41600101 Right-Hand S, T, W, X 20 528:1 26.0 3-Wire N41600102 Left-Hand S, T, W, X 20 528:1 26.0 3-Wire N41600103 Left-Hand K, N 20 528:1 26.0 3-Wire N41600104 Right-Hand K, N 20 528:1 26.0 3-Wire, p. 5

Ansaldo STS USA M-23A, M-23B, M-3 and Low-Profile M-23A and M-23B Machines with Mechanical Circuit Controller: Specifications and Ordering Information M-23B Switch Machines with Mechanical Circuit Controller Motor Gear Speed Control Order No. Layout Options (Vdc) Ratio (Sec.) Circuit Wiring N451160-0601 Right-Hand E, F 20 360:1 15.0 5-Wire N451160-0602 Left-Hand E, F 20 360:1 15.0 5-Wire N451160-0603 Left-Hand -- 20 528:1 26.0 5-Wire N451160-0604 Right-Hand -- 20 528:1 26.0 5-Wire N451160-0605 Right-Hand -- 20 360:1 15.0 5-Wire N451160-0606 Left-Hand -- 20 360:1 15.0 5-Wire N451160-0607 Left-Hand C, D 20 528:1 26.0 5-Wire N451160-0608 Right-Hand C, D 20 528:1 26.0 5-Wire N451160-0609 Left-Hand -- 110 189:1 4.5 5-Wire N451160-0610 Right-Hand -- 110 189:1 4.5 5-Wire N451160-0611 Right-Hand C, D 110 189:1 4.5 5-Wire N451160-0612 Left-Hand C, D 110 189:1 4.5 5-Wire N451160-0613 Right-Hand C, M 110 189:1 4.5 5-Wire N451160-0614 Left-Hand G, H 20 528:1 26.0 5-Wire N451160-0615 Right-Hand G, H 20 528:1 26.0 5-Wire N451160-0616 Left-Hand C, M 110 189:1 4.5 5-Wire N451160-0617 Left-Hand C, D 110 189:1 4.5 5-Wire N451160-0618 Left-Hand C, D 20 360:1 15.0 5-Wire N451160-0619 Left-Hand G, H 110 189:1 4.5 5-Wire N451160-0620 Right-Hand G, H 110 189:1 4.5 5-Wire N451160-0621 Right-Hand G, H 20 360:1 15.0 5-Wire N451160-0622 Left-Hand G, H 20 360:1 15.0 5-Wire N451160-0623 Right-Hand N 20 528:1 26.0 5-Wire N451160-0624 Left-Hand N 20 528:1 26.0 5-Wire N451160-0625 Left-Hand -- 20 528:1 26.0 5-Wire N451160-0626 Right-Hand -- 20 528:1 26.0 5-Wire N451160-0627 Right-Hand C, D 110 189:1 4.5 3-Wire N451160-0628 Left-Hand C, D 110 189:1 4.5 3-Wire N451160-0629 Left-Hand G, H 20 528:1 26.0 5-Wire N451160-0630 Right-Hand G, H 20 528:1 26.0 5-Wire N451160-0631 Left-Hand G, H 110 189:1 4.5 3-Wire N451160-0632 Right-Hand G, H 110 189:1 4.5 3-Wire N451160-0633 Right-Hand C, D 20 528:1 26.0 3-Wire N451160-0634 Left-Hand C, D 20 528:1 26.0 3-Wire N451160-0635 Left-Hand C, D 110 189:1 4.5 3-Wire N451160-0636 Right-Hand C, D 110 189:1 4.5 3-Wire N451160-0637 Left-Hand E, F 110 189:1 4.5 5-Wire N451160-0638 Right-Hand E, F 110 189:1 4.5 5-Wire N451160-0639 Right-Hand C, D 20 360:1 15.0 3-Wire N451160-0640 Left-Hand C, D 20 360:1 15.0 3-Wire N451160-0641 Left-Hand E, F 20 528:1 26.0 3-Wire N451160-0642 Right-Hand E, F 20 528:1 26.0 3-Wire N451160-0643 Left-Hand E, F 20 528:1 26.0 5-Wire N451160-0644 Right-Hand E, F 20 528:1 26.0 5-Wire N451160-0645 Left-Hand E, F 20 528:1 26.0 3-Wire N451160-0646 Right-Hand E, F 20 528:1 26.0 3-Wire N451160-0647 Left-Hand K, O, R 20 528:1 26.0 3-Wire N451160-0648 Right-Hand K, O, R 20 528:1 26.0 3-Wire N451160-0649 Left-Hand C, D, K, N, O, R 110 189:1 4.5 5-Wire N451160-0650 Right-Hand C, D, K, N, O, R 110 189:1 4.5 5-Wire N451160-0651 Left-Hand G, H 20 360:1 15.0 3-Wire N451160-0652 Right-Hand G, H 20 360:1 15.0 3-Wire N451160-0653 Left-Hand C, D 110 360:1 8.0 3-Wire N451160-0654 Right-Hand C, D 110 360:1 8.0 3-Wire N41600201 Right-Hand R, S, T, W 20 528:1 26.0 3-Wire N41600202 Left-Hand R, S, T, W 20 528:1 26.0 3-Wire N41600203 Right-Hand R, S, T, W 20 360:1 15.0 3-Wire N41600204 Left-Hand R, S, T, W 20 360:1 15.0 3-Wire, p. 6

M-23A, M-23B, M-3 and Low-Profile M-23A and M-23B Machines with ECC and MCU: Specifications and Ordering Information Ansaldo STS USA Specifications Weight: Dimen. (Overall): Motor Type: Motor Voltages: Motor RPM: Operating Times*: Clutch Settings: Control Ckt. Wiring: 860 lbs. (390 kg) 63.5 L x 33 W x 14 H (161.3 cm L x 83.8 cm W x 35.6 cm H) Fully enclosed perm. magnet type 20 Vdc or 110 Vdc (see tabs.) 500 RPM for 528:1 geared mach. 650 RPM for 360:1 geared mach. 1450 RPM for 189:1 geared mach. 4.5, 8.0, 15.0, or 26/34 sec. (see tabs) (*Per AREMA standards. Times will vary depending upon actual operating conditions.) 14A for 189:1 geared machines 10A or 23A for 360:1 geared machines 12A for 528:1 geared machines 2-wire Ordering Information To order M-23A or M-23B switch machines with ECC and MCU: Refer to Configuration Guide at right. Guide gives all available design and operating options, each denotes with a letter. Go to ordering tabulations and select machine with desired options. Ordering Information (cont d) Also select machine according to desired motor voltage, operating speed and gear ratio. Refer to RSE-6J1 for tools (switch layout and shop maintenance) used to maintain style M machines. If ordering M-23A or M-23B machines for a new switch layout, please supply all required specifications, and mounting dimensions according to approved track plans (contact your ASTS USA Account Executive for any assistance needed). Request ASTS USA Service Manual SM-9662 for switch machine replacement parts. Configuration Guide A 15-Watt, 115V Motor Heater B Lock Rod Openings Closed C (Reference not used in this catalog edition.) D Equipped with Local/Remote Feature E 30-Watt, 115/230V Motor Heater Wired for 115V F Painted per PP-7905 Aluminum G (Reference not used in this catalog edition.) H Surge Suppressor PCB I (Reference not used in this catalog edition.) J (Reference not used in this catalog edition.) K Motor Heater ON/OFF switch L (Not applicable to M-23A and M-23B machines.), p. 7

Ansaldo STS USA M-23A, M-23B, M-3 and Low-Profile M-23A and M-23B Machines with ECC and MCU: Specifications and Ordering Information M-23A Switch Machines with ECC and MCU Motor Gear Control Order No. Layout Options (Vdc) Ratio Circuit Wiring (3) Notes N42650101 Left-Hand E, H, F 110 189:1 2-Wire MCU (1) N42650102 Right-Hand E, H, F 110 189:1 2-Wire MCU (1) N42650103 Left-Hand E, H, F 110 360:1 2-Wire MCU (1) N42650104 Right-Hand E, H, F 110 360:1 2-Wire MCU (1) N42650105 Left-Hand B, H 110 189:1 2-Wire MCU (1) N42650106 Right-Hand B, H 110 189:1 2-Wire MCU (1) N42650107 Left-Hand E, F 20 528:1 2-Wire MCU (1) N42650108 Right-Hand E, F 20 528:1 2-Wire MCU (1) N42650109 Left-Hand A, D, H 110 189:1 2-Wire MCU (1) N42650111 Left-Hand A, D, H, K 110 189:1 2-Wire MCU (1) N42650112 Right-Hand A, D, H, K 110 189:1 2-Wire MCU (1) N42650113 Left-Hand D 20 528:1 2-Wire MCU (1) N42650114 Right-Hand D 20 528:1 2-Wire MCU (1) N42650117 Left-Hand A, D, H 110 189:1 2-Wire MCU (2) N42650118 Right-Hand A, D, H 110 189:1 2-Wire MCU (2) N42650119 Left-Hand A, D, H 110 189:1 2-Wire MCU (1) N42650120 Right-Hand A, D, H 110 189:1 2-Wire MCU (1) N42650121 Left-Hand A, D, F 20 528:1 2-Wire MCU (1) N42650122 Right-Hand A, D, F 20 528:1 2-Wire MCU (1) N42650127 Left-Hand B, D, F 20 528:1 2-Wire MCU (1) N42650128 Right-Hand B, D, F 20 528:1 2-Wire MCU (1) N42650129 Left-Hand A, D, H 110 189:1 2-Wire MCU (1) N42650130 Right-Hand A, D, H 110 189:1 2-Wire MCU (1) N42650131 Left-Hand E, F 20 360:1 2-Wire MCU (1) N42650132 Right-Hand E, F 20 360:1 2-Wire MCU (1) Note (1): Configured for near point detection. Note (2): Configured for far point detection. Note (3): Wayside provides bipolar 2-wire motor feed to select Normal or Reverse motion. When one wire is "+", other wire is "-". ECC/MCU passes wayside polarity to motor terminals to obtain Normal or Reverse motion. M-23B Switch Machines with ECC and MCU Motor Gear Control Order No. Layout Options (Vdc) Ratio Circuit Wiring (4) Notes N42650201 Left-Hand A, D, H 110 189:1 2-Wire MCU (1) N42650202 Right-Hand A, D, H 110 189:1 2-Wire MCU (1) N42650207 Left-Hand E, F 20 528:1 2-Wire MCU (1) N42650208 Right-Hand E, F 20 528:1 2-Wire MCU (1) N42650209 Left-Hand A, D, H 110 189:1 2-Wire MCU (1) N42650210 Right-Hand A, D, H 110 189:1 2-Wire MCU (1) N42650219 Left-Hand A, D, H 110 189:1 2-Wire MCU (1) (2) N42650220 Right-Hand A, D, H 110 189:1 2-Wire MCU (1) (2) N42650221 Left-Hand A, D, H 110 189:1 2-Wire MCU (2) (3) N42650222 Right-Hand A, D, H 110 189:1 2-Wire MCU (2) (3) Note (1): Configured for near point detection. Note (2): Without auxiliary point detection proximity sensors (in all other machines). Note (3): Configured for far point detection. Note (4): Wayside provides bipolar 2-wire motor feed to select Normal or Reverse motion. When one wire is "+", other wire is "-". ECC/MCU passes wayside polarity to motor terminals to obtain Normal or Reverse motion., p. 8

M-23A, M-23B, M-3 and Low-Profile Ansaldo STS USA M-23A and M-23B Machines with Independent Point Detection: Specifications and Ordering Information Ordering Information To order M-23A or M-23B switch machines with independent point detection: Refer to Configuration Guide below. Guide gives all available design and operating options, each denotes with a letter. Go to ordering tabulations and select machine with desired options. Also select machine according to desired motor voltage, operating speed and gear ratio. Refer to RSE-6F3 to order retrofit Electronic Circuit Controller (ECC) for style M machines with mechanical circuit controllers. Refer to RSE-6F4 to order retrofit Electronic Biased Neutral Controller (EBNC) for M-23A and M-23B switch machines. Specifications Weight: Dimen. (Overall): Motor Type: Motor Voltages: Motor RPM: Operating Times*: Clutch Settings: Control Ckt. Wiring: 860 lbs. (390 kg) 63.5 L x 33 W x 14 H (161.3 cm L x 83.8 cm W x 35.6 cm H) Fully enclosed perm. magnet type 20 Vdc or 110 Vdc (see tabs.) 500 RPM for 528:1 geared mach. 650 RPM for 360:1 geared mach. 1450 RPM for 189:1 geared mach. 5.0 sec. (*Per AREMA standards. Times will vary depending upon actual operating conditions.) 14A for 189:1 geared machines 23A for 360:1 geared machines 12A for 528:1 geared machines 3-wire Refer to RSE-6J1 for tools (switch layout and shop maintenance) used to maintain style M machines. If ordering M-23A or M-23B machines for a new switch layout, please supply all required specifications, and mounting dimensions according to approved track plans (contact your ASTS USA Account Executive for any assistance needed). Request ASTS USA Service Manual SM-9671 for switch machine replacement parts. Configuration Guide A-H (References not used in this catalog edition.) I Aluminum paint J, L (References not used in this catalog edition.) M-23A Switch Machines with Independent Point Detection Motor Gear Speed Control Order No. Layout Options (Vdc) Ratio (Sec.) Circuit Wiring N43925101 Left-Hand I, M 110 189:1 5 3-wire N43925102 Right-Hand I, M 110 189:1 5 3-wire M-23B Switch Machines with Independent Point Detection Motor Gear Speed Control Order No. Layout Options (Vdc) Ratio (Sec.) Circuit Wiring N43925201 Left-Hand I, M 110 189:1 5 3-wire N43925502 Right-Hand I, M 110 189:1 5 3-wire, p. 9

Ansaldo STS USA M-23A, M-23B, M-3 and Low-Profile M-3 Switch Machine with Mechanical Circuit Controller: Specifications and Ordering Information Ordering Information (cont d) Refer to RSE-6A4 for the following support equipment: Permanent magnet retrofit motor kits for old style M- 3, M-23A and M-23B machines. Latchout kit. Latch stand. Point detector bars Lock rods and lock connecting rods Specifications Weight: 810 lbs. (367 kg) Dimen. (Overall): 63.5 L x 33 W x 10.25 H (161.3 cm L x 83.8 cm W x 26.0 cm H) Motor Type: Fully enclosed perm. magnet type Motor Voltages: 20 Vdc or 110 Vdc (see tabs.) Motor RPM: 500 RPM for 528:1 geared mach. 650 RPM for 360:1 geared mach. 1450 RPM for 189:1 geared mach. Operating Times*: 4.5, 8.0 and 26.0 sec. (see tabs.) (*Per AREMA standards. Times will vary depending upon actual operating conditions.) Clutch Settings: 14A for 189:1 gearing Control Ckt. Wiring: 3-wire or 5-wire (see ordering tabs) Ordering Information To order a standard M-3 switch machines with mechanical circuit controller: Refer to Configuration Guide at right. Guide gives all available design and operating options, each denotes with a letter. Go to ordering tabulations and select machine with desired options. Also select machine according to desired motor voltage, operating speed and gear ratio. Refer to RSE-6F3 to order retrofit Electronic Circuit Controller (ECC) for style M machines with mechanical circuit controllers. Refer to RSE-6J1 for tools (switch layout and shop maintenance) used to maintain style M machines. If ordering style M-3 machines for a new switch layout, please supply all required specifications, and mounting dimensions according to approved track plans (contact your ASTS USA Account Executive for any assistance needed). Request ASTS USA Service Manual SM-6263 for switch machine replacement parts. Configuration Guide A 15W, 230V Heater in Circuit Controller B 15W, 230V Heater for Motor C 15W, 115V Heater in Circuit Controller D 15W, 115V Heater for Motor E 15W, 115/230V Heater in Circuit Controller F 15W, 115/230V Heater for Motor G 15W, 24V Heater in Circuit Controller H 15W, 24V Heater for Motor J Lock Rod Openings Closed K Provided without Main Terminal Board L Uses Harness N320067 (Flag Type Terminals) M Uses Harness N320069 (Flag Type Terminals) N Uses Circuit Controller without Point. Detector Latch O Clutch Set at 14 Amperes P Clutch Set at 10 Amperes Q Assembled without Latch for Retaining Machine in the Off-Power Position when Hand Crank Cover is Open R Aluminum Paint, p. 10

M-23A, M-23B, M-3 and Low-Profile Ansaldo STS USA M-3 Switch Machine with Mechanical Circuit Controller: Specifications and Ordering Information Configuration Guide (cont d) S LH Switch Machine Set Up for RH Indication or RH Switch Machine Set Up for LH Indication T 15w, 115v Heater for Motor. U Equipped With Telephone Jack in the Circuit Controller V For LH Switch Machine Set Up for RH Indication Machine is Stenciled LH Far Pt Cl. For RH Switch Machine Set Up for LH Indication Machine is Stenciled RH Far Pt. Cl. W X Y 1-1/4 Threaded Conduit Outlet Uses Crank Case Cover (N146290-002) Pipe Plug (J032902) Not Required (Reference not used in this catalog edition.) Standard M-3 Switch Machines with Mechanical Circuit Controller Motor Gear Speed Control Order No. Layout Options (Vdc) Ratio (Sec.) Circuit Wiring N451160-0301 Right Hand C, L 20 528:1 26.0 5-Wire N451160-0302 Left Hand C, L 110 528:1 4.5 5-Wire N451160-0303 Right Hand C, M 110 189:1 4.5 5-Wire N451160-0304 Left Hand C, M 110 189:1 4.5 5-Wire N451160-0305 Right Hand C, D 110 189:1 4.5 5-Wire N451160-0306 Left Hand C, D 110 189:1 4.5 5-Wire N451160-0307 Right Hand C, D 110 189:1 4.5 3-Wire N451160-0308 Left Hand C, D 110 189:1 4.5 3-Wire N451160-0309 Left Hand E, F 110 189:1 4.5 5-Wire N451160-0310 Right Hand E, F 110 189:1 4.5 5-Wire N451160-0311 Left Hand C, D, J 110 189:1 4.5 3-Wire N451160-0312 Right Hand C, D, J 110 189:1 4.5 3-Wire N451160-0313 Right Hand X 110 189:1 4.5 3-Wire N451160-0314 Left Hand X 110 189:1 4.5 3-Wire N451160-0315 Right Hand C, D, Q 110 189:1 4.5 3-Wire N451160-0316 Left Hand C, D, Q 110 189:1 4.5 3-Wire N451160-0317 Right Hand -- 110 189:1 4.5 3-Wire N451160-0318 Left Hand -- 110 189:1 4.5 3-Wire N451160-0319 Right Hand C, D 110 189:1 4.5 3-Wire N451160-0320 Left Hand C, D 110 189:1 4.5 3-Wire N451160-0322 Left Hand D, S, W 110 189:1 4.5 3-Wire N451160-0323 Right Hand D, S, W 110 189:1 4.5 3-Wire N451160-0324 Left Hand C, D, J 110 189:1 4.5 3-Wire N451160-0325 Right Hand C, D, J 110 189:1 4.5 3-Wire N451160-0326 Left Hand C, D, P, S 110 360:1 8.0 3-Wire (Tabulation continued on following page.), p. 11

Ansaldo STS USA M-23A, M-23B, M-3 and Low-Profile M-3 Switch Machine with Mechanical Circuit Controller: Specifications and Ordering Information (Tabulation continued from previous page.) Standard M-3 Switch Machines with Mechanical Circuit Controller Motor Gear Speed Control Order No. Layout Options (Vdc) Ratio (Sec.) Circuit Wiring N451160-0327 Right Hand C, D, P, S 110 360:1 8.0 3-Wire N451160-0328 Left Hand C, D, J, R 110 189:1 4.5 3-Wire N451160-0329 Right Hand C, D, J, R 110 189:1 4.5 3-Wire N451160-0330 (1) Left Hand C, T, U 110 189:1 4.5 2-Wire N451160-0331 (1) Right Hand C, T, U 110 189:1 4.5 2-Wire N451160-0332 Left Hand C, D, J, P 110 360:1 8.0 3-Wire N451160-0333 Right Hand C, D, J, P 110 360:1 8.0 3-Wire N451160-0334 Left Hand C, D, J, P 110 360:1 8.0 3-Wire N451160-0335 Right Hand C, D, J, P 110 360:1 8.0 3-Wire N451160-0336 Left Hand C, D, J, P, S 110 360:1 8.0 3-Wire N451160-0337 Right Hand C, D, J, P, S 110 360:1 8.0 3-Wire N451160-0338 (1) Left Hand C, T, U, S 110 189:1 4.5 2-Wire N451160-0339 (1) Right Hand C, T, U, S 110 189:1 4.5 2-Wire N451160-0340 Left Hand C, D, S, V 110 189:1 4.5 3-Wire N451160-0341 Right Hand C, D, S, V 110 189:1 4.5 3-Wire N451160-0342 Left Hand C, D, U 110 189:1 4.5 3-Wire N451160-0343 Right Hand C, D, U 110 189:1 4.5 3-Wire N451160-0344 Left Hand C, D, S, U, V 110 189:1 4.5 3-Wire N451160-0345 Right Hand C, D, S, U, V 110 189:1 4.5 3-Wire N451160-4001 Left Hand C, D, J 110 189:1 4.5 3-Wire N451160-4002 Right Hand C, D, J 110 189:1 4.5 3-Wire N451160-4003 Left Hand C, D, P, S, V 110 360:1 8.0 3-Wire N451160-4004 Right Hand C, D, P, S, V 110 360:1 8.0 3-Wire N451160-4005 Left Hand C, D, J 110 189:1 4.5 3-Wire N451160-4006 Right Hand C, D, J 110 189:1 4.5 3-Wire Note (1): Machines available for replacement of Alstom/GRS machines with 2-wire control. Request Service Manual SM-6263 or contact ASTS USA for conversion kit. These machines include two 15W/115V heaters (for motor and circuit controller), and telephone jack in circuit controller compartment. -0338 and -0338 machines are L.H. for R.H. indication, or R.H. for L.H. indication., p. 12

M-23A, M-23B, M-3 and Low-Profile Ansaldo STS USA M-3 Machines with ECC and EBNC: Specifications and Ordering Information Specifications Weight: 810 lbs. (367 kg) Dimen. (Overall): 63.5 L x 33 W x 10.25 H (161.3 cm L x 83.8 cm W x 26.0 cm H) Motor Type: Fully enclosed perm.magnet type Motor Voltages: 20 Vdc or 110 Vdc (see tabs.) Motor RPM: 500 RPM for 528:1 geared mach. 650 RPM for 360:1 geared mach. 1450 RPM for 189:1 geared machines Operating Times*: 4.5 or 8.0 sec. (see tabs) (*Per AREMA standards. Times will vary depending upon actual operating conditions.) Clutch Settings: 14A for 189:1 gearing Control Ckt. Wiring: 2-wire Ordering Information To order M-3 switch machines with ECC and EBNC: Refer to Configuration Guide below. Guide gives all available design and operating options, each denotes with a letter. Ordering Information (cont d) Go to ordering tabulations and select machine with desired options. Also select machine according to desired motor voltage, operating speed and gear ratio. Refer to RSE-6J1 for tools (switch layout and shop maintenance) used to maintain style M machines. If ordering M-3 machines for a new switch layout, please supply all required specifications, and mounting dimensions according to approved track plans (contact your ASTS USA Account Executive for any assistance needed). Request ASTS USA Service Manual SM-9662 for switch machine replacement parts. Configuration Guide A 15-Watt, 115V Motor Heater B, C (References not used in this catalog edition.) D Equipped with Local/Remote Feature E-K (References not used in this catalog edition.) L Surge Suppressor PCB Standard M-3 Machines with ECC and EBNC Motor Gear Control Order No. Layout Options (Vdc) Ratio Circuit Wiring Notes N42950013 Left Hand A, D, L 110 189:1 2-wire EBNC (1) N42950014 Right Hand A, D, L 110 189:1 2-wire EBNC (1) Note (1): Wayside provides fixed-polarity 2-wire motor power feed. One wire always "+" and other wire always "-". ECC/EBNC controls polarity applied to motor terminals to select Normal or Reverse operation., p. 13

Ansaldo STS USA M-23A, M-23B, M-3 and Low-Profile M-3 Machines with Independent Point Detection: Specifications and Ordering Information Specifications Weight: 810 lbs. (367 kg) Dimen. (Overall): 63.5 L x 33 W x 10.25 H (161.3 cm L x 83.8 cm W x 26.0 cm H) Motor Type: Fully enclosed perm. magnet type Motor Voltages: 20 Vdc or 110 Vdc (see tabs.) Motor RPM: 500 RPM for 528:1 geared mach. 650 RPM for 360:1 geared mach. 1450 RPM for 189:1 geared mach. Operating Times*: 3.0 sec. (*Per AREMA standards. Times will vary depending upon actual operating conditions.) Clutch Settings: All machines: 14A for 189:1 geared mach. Control Ckt. Wiring: 3-wire Ordering Information To order M-3 or switch machines with independent point detection: Refer to Configuration Guide below. Guide gives all available design and operating options, each denotes with a letter. Ordering Information (cont d) Go to ordering tabulations and select machine with desired options. Also select machine according to desired motor voltage, operating speed and gear ratio. Refer to RSE-6J1 for tools (switch layout and shop maintenance) used to maintain style M machines. If ordering M-3 machines for a new switch layout, please supply all required specifications, and mounting dimensions according to approved track plans (contact your ASTS USA Account Executive for any assistance needed). Request ASTS USA Service Manual SM-9671 for switch machine replacement parts. Configuration Guide A 15W, 115V Heater in Circuit Controller B 15W, 115V Heater in Motor C-L (References not used in this catalog edition.) M Circuit Controller without Latch Cam Block M-3 Switch Machines with Independent Point Detection Motor Gear Speed Control Order No. Layout Options (Vdc) Ratio (Sec.) Circuit Wiring N43925001 Left-Hand A, B, M 110 189:1 3 3-wire N43925002 Right-Hand A, B, M 110 189:1 3 3-wire, p. 14

M-23A, M-23B, M-3 and Low-Profile Ansaldo STS USA Low-Profile M-3 Machines: Specifications and Ordering Information Specifications Weight: 810 lbs. (367 kg) Dimen. (Overall): Length: 63.5 (161.3 cm) Width: 19 W (48.25 cm) - not including bars and covers. Height: With mounting plate = 9-7/8 (25.1 cm) Height: Without mounting plate = 9-5/8 (24.4 cm) Motor Type: Fully enclosed permanent magnet type Motor Voltage: 110 Vdc Motor RPM: 1430 RPM Gear Ratio: 189:1 Op. Bar Stroke: 6 (15.2 cm) Operating Time*: 5.0 seconds (*Per AREMA standards. Times will vary depending upon actual operating conditions.) Clutch Setting: 13A Control Ckt. Wiring: 3-wire Ordering Information To order a Low Profile M-3 switch machine, refer to tabulation below. If ordering style M-3 machines for a new switch layout, please supply all required specifications, and mounting dimensions according to approved track plans (contact your ASTS USA Account Executive for any assistance needed). Refer to RSE-6J1 for tools (switch layout and shop maintenance) used to maintain style M machines. Request ASTS USA Service Manual SM-6444 for switch machine replacement parts. Low-Profile M-3 Switch Machine with Mechanical Circuit Controller Point Motor Speed Gear Clutch Det. Heaters Order No. Layout (Vdc) (Sec.) Ratio Control Setting Latch (1) N451160-1401 Left-Hand 110 4.5 189:1 3-Wire 13A X X N451160-1501 Right-Hand 110 4.5 189:1 3-Wire 13A X X Note (1): Machines equipped with circuit controller and motor compartment heaters. MicroLok is a registered trademark of Ansaldo STS USA, Inc., p. 15

, p. 16