MEDIUM VOLTAGE VACUUM CONTACTOR T300MVi JK OEM POWER CELLS Reliability in motion Reliability in motion 400 AMPERE AT 2300-6600 VOLTS (7200 VOLT MAX) DRAWOUT AND FIXED APPLICATIONS
JK OEM PART NUMBER DESCRIPTION APPLICATION Fix type OEM Motor hp rating up to 1500hp GCV5084L03G01 with single Fix type OEM Motor hp rating up to 3000hp GCV5084L03G02 with double GCV5084L03G03 Fix type for CPT/PT/CB Includes Toshibaʼs Isolation Bolted Pressure Switch for disconnecting CPT/PTʼs Provision to fix mount 1 or 2 CPT/PTʼs w/mounting provision for secondary low voltage circuit breaker. Fix type for CPT/PT/LS Includes Toshibaʼs Isolation GCV5084L03G04 Bolted Pressure Switch for disconnecting CPT/PTʼs Provision to fix mount 1 or 2 CPT/PTʼs w/ limit switch. Drawout type without Used when up stream protection GCV5084L04G00 GCV5084L04G01 GCV5084L04G02 GCV5084L05G01 GCV5084L05G02 GCV5084L06G01 GCV5084L06G02 fuses Drawout type OEM with single Drawout type OEM with double Fix latched type OEM with single Fix latched type OEM with double Drawout latched type OEM with single Drawout latched type OEM with double is provided. Motor hp rating up to 1500hp Motor hp rating up to 3000hp For distribution loads (400 A For distribution loads (400 A For distribution loads ( 400 A For distribution loads (400 A New application using JK OEM Power Cell for outdoor skid mounted compressor
CONTACTOR RATINGS Rated Voltage Rated Current HCV-5HA Interrupting Capacity Permissible Switching Frequency Mechanical Life Electrical Life Closing Time Opening Time 7200 Volts 400 Amps 7000A RMS Symmetrical @5000V Max. 4500A RMS Symmetrical @7200V Max. 1200/Hour 2,500,000 Operations 250,000 Operations 80 ms or less 25 ms or less Arcing Time Pick-Up Voltage AC or DC Drop-Out Voltage AC or DC Rated Control Voltage AC Rated Control Voltage DC Coil Circuit Inrush Coil Circuit Holding Auxiliary Contact Arrangement 10 ms or less 85% Rated (Hot) - 70% Rated (Cold) 50% Rated (Hot) - 40% Rated (cold) 115/120 or 230/240 V 50/60 Hz 120/125 or 240/250 V 670 VA AC (700 W DC) 85 VA AC (85 W DC) 3 N.O. - 3 N.C. Auxiliary Contact Rating 10 A, 600 V (NEMA Class A600) HCV-5HAL (Latched Type Only) Permissible Switching Frequency Mechanical Life Tripping Voltage Tripping Current 300/Hour 250,000 Operations 40-60% Rating DC 4.8 A DC Max System Voltage 2.2-2.5kV 3.0-3.3kV 4.0-5.0kV 6.0-6.6kV 0.8PF Ind/Syn Motor 1750HP 2250HP 3000HP 4500HP General Application and Load Data 1.0PF Syn Motor 2000HP 2500HP 3500HP 5000HP 3 Phase Transformer 1500kVA 2000kVA 3000kVA 4000kVA 3 Phase Capacitor 1500kVAR 2000kVAR 2000kVAR 2000kVAR The above table is based on general load data and standard application. Lower limitations may apply on specific applications (i.e. applications above 6600 feet elevations). CTi Automation - Phone: CONTACTOR 800.894.0412 RATINGS- Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
JK OEM Power Cells installed and connected in customers existing cabinetry. This Pumping Station is equipped with Air Contactor Type Across the Line Starters and was faced with the high cost of replacement parts and un-scheduled downtimes. Local OEM modified the existing cubicles and replaced two of the six old style starters with the JK OEM Power Cells. The remainders of the old style Air Contactors were replaced during scheduled maintenance shut downs. Modified Starter Cubicles with the JK OEM Power Cells The Power Cells was used to replace old style AIR DRAWOUT CIRCUIT BREAKER Controlgear protecting and controlling motor loads within an existing facility. The continuous failure of the mechanical mechanisms and costly electrical contact replacement forced the user to consider replacing the entire existing Controlgear. Valuable real-estate and labor dollars was saved by reusing the existing cabinets and conduits plus upgrade to current vacuum technology electrical controllers. Existing Air Breaker Cubicle with the Old Style Air Circuit Breaker installed JK OEM Power Cell installed in Existing Cubicle Viewing Window to view the position of the Isolation Switch Blades Viewing Port for Fuses Isolation Bolted Pressure Switch Operating Handle
LOCKED POWER ISOLATION SWITCH O N O FF F POWER ISOLATION SWITCH O N F F O The JK OEM Power Cells are UL Listed The compact design will allow for either motor or distribution applications. Design can be totally front accessible. The OEM Power Cells are designed to replace existing air or old vacuum contactor applications when used for motor or small distribution feeders. The kit provides you with state-of-the-art Toshiba vacuum technology and the patented bolted pressure isolation switch. Standard features include: Patented bolted pressure isolation switch Main power fuse clips (single or double barrel) Mechanical interlocking system Toshiba HCV-5HA vacuum contactor The JK OEM Power Cells will allow the customer to use their standard cubicles, wiring methods and components. 5.00 5.00 8.67 32.56 DRAWOUT CONFIGURATION 1.00 2.25 4.50 29.29 21.05 22.73 20.03 LINE TERMINALS 15.86 14.58 8.98 26.53 31.80 TOP VIEW 23.83 RIGHT SIDE FRONT VIEW 26.220 FIXED MOUNTED CONFIGURATION 2.25 4.50 29.29 O F FF F 20.03 LINE TERMINALS 20.03 LINE TERMINALS 22.06 19.71 14.58 3.62 3.000 22.06 FRONT VIEW 31.80 SIDE VIEW 26.225 TOP VIEW
Houston,Texas G7 Drive Low Voltage Motor UPS Product Warranty Toshiba offers a comprehensive warranty program on its full line of industrial products. Consult your salesperson or the factory for specific information. Customer Support Services Toshiba offers 24-hour service nationwide. For assistance of any type, Medium Voltage Drive Need to Know More? With more than a half a million square feet under one roof, Toshiba s facility in Houston, Texas is one of the largest drive and motor manufacturing facilities in the U.S. From this facility, Toshiba offers solutions which include integrated motor drive packages, turnkey bypass assemblies and custom jobs built to your specification. Be sure to visit out web site for the lat-est information on Toshiba products. Exceed all Expectations. Medium Voltage Motor At Toshiba drives are what we do best. In an effort to significantly reduce the long lead-times and expensive custom engineering often associated with the manufacture of medium voltage drives, Toshiba now offers a line of products to meet the ever changing needs of out most valuable assets: our diverse, worldwide customer base. Through intense interaction with our customers we have been able to develop the best product for medium voltage motor applications Reliability in motion