T300MVi JK OEM POWER CELLS MEDIUM VOLTAGE VACUUM CONTACTOR. Reliability in motion. Reliability in motion

Similar documents
SafeGear TM Motor Control Center Arc resistant metal-clad construction

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches

JOSLYN CLARK VACUUM CONTACTOR FEATURES

INSTRUCTION MANUAL. HCV-5HA 7.2kV, 400A-7.0kA HCV-5HAL 7.2kV, 400A-7.0kA INSTALLATION - OPERATION - MAINTENANCE

Horizontal Circuit Switchers

JOSLYN CLARK VACUUM CONTACTORS

CTi Automation - Phone: Fax: Web:

Ampgard medium voltage motor control renewal parts

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

HCV-5HA 7.2kV, 400A-7.0kA HCV-5HAL 7.2kV, 400A-7.0kA

Horizontal Circuit Switchers

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

SWITCHGEAR DIVISION PRODUCT PROFILES

Joslyn Clark Controls, Inc. Simple, Safe, Retrofit Programs to Significantly Extend Life of Existing Circuit Breakers

C1000 Series Automatic Cap Bank

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Section 18. Medium Voltage Equipment. BuyLog Catalog 18-1

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

DS/DSII Low Voltage Switchgear. Renewal Parts. Cutler-Hammer. Renewal Parts. Effective: October Page 1

Critical Power Switchboards. Selection and Application Guide

Air-insulated switchgear UniGear type ZS1

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

SL Series IEC Vacuum Contactors. Medium Voltage Contactors Technical Focus

Low & Medium Voltage Vacuum Contactors

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

Standby Power Systems

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

Vacuum Contactors and Starters

Table of Contents. HCC Contactor Nomenclature

Service Entrance Methods

Specialty Service Entrance Switchboards. Selection and Application Guide

CWM_N NEMA Rated Contactors

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Ktec Contactors and thermal overloads

Installation and Construction Notes for EVSE4

CI-TI Contactors and motor starters Types CI 61 - CI 98

SECTION MOTOR CONTROL

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Pump Panel Specifications

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Mica Element Support. Compacted Quartz Sand. Length B

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications

Motorpact Medium Voltage Motor Controller. Innovative solutions that deliver high performance and reliability

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Multi-Pak Group Control

Auxiliary Relay. Type RXP8n, RXPQ8n

Power System Solutions (PSS)

Power Break II Switchboard

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

SECTION PANELBOARDS

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

SECTION MOTOR CONTROLLERS

About us. Switchgear Factory, Mumbai

Controls. CONTACTORS CWB Line (up to 40A)

AF series contactors (9 2650)

Solid-State Relays. Solid-State Relays. Features. Description. Overview

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

Recommended Procedures

Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems

SECTION MOTOR STARTERS (AMPGARD) MEDIUM VOLTAGE

Solid-State Relays. Solid-State Relays. Features. Description. Overview

Instructions for AMPGARD 400A medium voltage starter

MaxPak Plus Analog DC V S Drive

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

Power/Vac OEM Express Switchgear

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Industry Automation Control Components

Bolted contact switches. Pringle switches

LG HRC Power Fuses ISO 9001 ISO 14001

AF40... AF96 3-pole contactors Technical data

Industrial Products Pipeline Solutions

Low-Peak 600V Class RK1

3TM Vacuum Contactors

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B

CI-TI Contactors and Motor Starters Type CI 6-50

AF series contactors (9 2650)

Unitole UP kv Primary substations Motor control centres

Transcription:

MEDIUM VOLTAGE VACUUM CONTACTOR T300MVi JK OEM POWER CELLS Reliability in motion Reliability in motion 400 AMPERE AT 2300-6600 VOLTS (7200 VOLT MAX) DRAWOUT AND FIXED APPLICATIONS

JK OEM PART NUMBER DESCRIPTION APPLICATION Fix type OEM Motor hp rating up to 1500hp GCV5084L03G01 with single Fix type OEM Motor hp rating up to 3000hp GCV5084L03G02 with double GCV5084L03G03 Fix type for CPT/PT/CB Includes Toshibaʼs Isolation Bolted Pressure Switch for disconnecting CPT/PTʼs Provision to fix mount 1 or 2 CPT/PTʼs w/mounting provision for secondary low voltage circuit breaker. Fix type for CPT/PT/LS Includes Toshibaʼs Isolation GCV5084L03G04 Bolted Pressure Switch for disconnecting CPT/PTʼs Provision to fix mount 1 or 2 CPT/PTʼs w/ limit switch. Drawout type without Used when up stream protection GCV5084L04G00 GCV5084L04G01 GCV5084L04G02 GCV5084L05G01 GCV5084L05G02 GCV5084L06G01 GCV5084L06G02 fuses Drawout type OEM with single Drawout type OEM with double Fix latched type OEM with single Fix latched type OEM with double Drawout latched type OEM with single Drawout latched type OEM with double is provided. Motor hp rating up to 1500hp Motor hp rating up to 3000hp For distribution loads (400 A For distribution loads (400 A For distribution loads ( 400 A For distribution loads (400 A New application using JK OEM Power Cell for outdoor skid mounted compressor

CONTACTOR RATINGS Rated Voltage Rated Current HCV-5HA Interrupting Capacity Permissible Switching Frequency Mechanical Life Electrical Life Closing Time Opening Time 7200 Volts 400 Amps 7000A RMS Symmetrical @5000V Max. 4500A RMS Symmetrical @7200V Max. 1200/Hour 2,500,000 Operations 250,000 Operations 80 ms or less 25 ms or less Arcing Time Pick-Up Voltage AC or DC Drop-Out Voltage AC or DC Rated Control Voltage AC Rated Control Voltage DC Coil Circuit Inrush Coil Circuit Holding Auxiliary Contact Arrangement 10 ms or less 85% Rated (Hot) - 70% Rated (Cold) 50% Rated (Hot) - 40% Rated (cold) 115/120 or 230/240 V 50/60 Hz 120/125 or 240/250 V 670 VA AC (700 W DC) 85 VA AC (85 W DC) 3 N.O. - 3 N.C. Auxiliary Contact Rating 10 A, 600 V (NEMA Class A600) HCV-5HAL (Latched Type Only) Permissible Switching Frequency Mechanical Life Tripping Voltage Tripping Current 300/Hour 250,000 Operations 40-60% Rating DC 4.8 A DC Max System Voltage 2.2-2.5kV 3.0-3.3kV 4.0-5.0kV 6.0-6.6kV 0.8PF Ind/Syn Motor 1750HP 2250HP 3000HP 4500HP General Application and Load Data 1.0PF Syn Motor 2000HP 2500HP 3500HP 5000HP 3 Phase Transformer 1500kVA 2000kVA 3000kVA 4000kVA 3 Phase Capacitor 1500kVAR 2000kVAR 2000kVAR 2000kVAR The above table is based on general load data and standard application. Lower limitations may apply on specific applications (i.e. applications above 6600 feet elevations). CTi Automation - Phone: CONTACTOR 800.894.0412 RATINGS- Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

JK OEM Power Cells installed and connected in customers existing cabinetry. This Pumping Station is equipped with Air Contactor Type Across the Line Starters and was faced with the high cost of replacement parts and un-scheduled downtimes. Local OEM modified the existing cubicles and replaced two of the six old style starters with the JK OEM Power Cells. The remainders of the old style Air Contactors were replaced during scheduled maintenance shut downs. Modified Starter Cubicles with the JK OEM Power Cells The Power Cells was used to replace old style AIR DRAWOUT CIRCUIT BREAKER Controlgear protecting and controlling motor loads within an existing facility. The continuous failure of the mechanical mechanisms and costly electrical contact replacement forced the user to consider replacing the entire existing Controlgear. Valuable real-estate and labor dollars was saved by reusing the existing cabinets and conduits plus upgrade to current vacuum technology electrical controllers. Existing Air Breaker Cubicle with the Old Style Air Circuit Breaker installed JK OEM Power Cell installed in Existing Cubicle Viewing Window to view the position of the Isolation Switch Blades Viewing Port for Fuses Isolation Bolted Pressure Switch Operating Handle

LOCKED POWER ISOLATION SWITCH O N O FF F POWER ISOLATION SWITCH O N F F O The JK OEM Power Cells are UL Listed The compact design will allow for either motor or distribution applications. Design can be totally front accessible. The OEM Power Cells are designed to replace existing air or old vacuum contactor applications when used for motor or small distribution feeders. The kit provides you with state-of-the-art Toshiba vacuum technology and the patented bolted pressure isolation switch. Standard features include: Patented bolted pressure isolation switch Main power fuse clips (single or double barrel) Mechanical interlocking system Toshiba HCV-5HA vacuum contactor The JK OEM Power Cells will allow the customer to use their standard cubicles, wiring methods and components. 5.00 5.00 8.67 32.56 DRAWOUT CONFIGURATION 1.00 2.25 4.50 29.29 21.05 22.73 20.03 LINE TERMINALS 15.86 14.58 8.98 26.53 31.80 TOP VIEW 23.83 RIGHT SIDE FRONT VIEW 26.220 FIXED MOUNTED CONFIGURATION 2.25 4.50 29.29 O F FF F 20.03 LINE TERMINALS 20.03 LINE TERMINALS 22.06 19.71 14.58 3.62 3.000 22.06 FRONT VIEW 31.80 SIDE VIEW 26.225 TOP VIEW

Houston,Texas G7 Drive Low Voltage Motor UPS Product Warranty Toshiba offers a comprehensive warranty program on its full line of industrial products. Consult your salesperson or the factory for specific information. Customer Support Services Toshiba offers 24-hour service nationwide. For assistance of any type, Medium Voltage Drive Need to Know More? With more than a half a million square feet under one roof, Toshiba s facility in Houston, Texas is one of the largest drive and motor manufacturing facilities in the U.S. From this facility, Toshiba offers solutions which include integrated motor drive packages, turnkey bypass assemblies and custom jobs built to your specification. Be sure to visit out web site for the lat-est information on Toshiba products. Exceed all Expectations. Medium Voltage Motor At Toshiba drives are what we do best. In an effort to significantly reduce the long lead-times and expensive custom engineering often associated with the manufacture of medium voltage drives, Toshiba now offers a line of products to meet the ever changing needs of out most valuable assets: our diverse, worldwide customer base. Through intense interaction with our customers we have been able to develop the best product for medium voltage motor applications Reliability in motion