PERFORMANCE DATA 3-PHASE INDUCTION MOTOR

Similar documents
PERFORMANCE DATA 3-PHASE INDUCTION MOTOR

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS. Frames 143T - 449T

AC Induction Motors. Installation and operating instructions

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL

SECTION MOTOR REQUIREMENTS for HVAC

RGZESDI Inverter Duty AC Induction Motors

MAX-E1 HIGH EFFICIENCY. Severe Duty

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

3 Phase AC Induction Motors

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities.

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS

1329R Small AC Motors

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

MARLEY ENGINEERED PRODUCTS OPERATING INSTRUCTIONS AND PARTS LIST

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

Motor Installation And Maintenance Instructions

Modifiable TITAN Horizontal Motors Accessories and Modifications

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

Mounting & Maintenance Instructions OMT1 & OMT2 Motors

DATA SHEET. Three Phase Induction Motor - Squirrel Cage. Customer : Product code : : W22 NEMA Premium Efficiency Three-Phase

PERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

Powerful + Efficient + Reliable

Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F

MOUNTING & MAINTENANCE INSTRUCTIONS FOR

Integral Horsepower AC Induction Motors ODP Enclosure TEFC Enclosure

Product Information Packet ECP50504L-4 500HP,1789RPM,3PH,60HZ,5010,TEFC,F1

Maximum operating temperature for standard motors = 110 C. Shut down temperature in case of a malfunction = 115 C.

Section 5 Reports Installation & Start Up Reports... Reports 1-3 Maintenance Report Warranty & RGA Information Contact Information

SECTION ELECTRIC MOTORS

Ariel Performance Compressor Data: Driver Data: Services Service 1 Stage Data: Cylinder Data: Throw 1 Throw 2 BOLD BOLD

Motor Protection Fundamentals. Motor Protection - Agenda

Installation & Maintenance Manual

SUPER-MAX INDUCTION MOTOR

Transformer Installation, Operation, and Maintenance Manual

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev

OPERATION & MAINTENANCE MANUAL

Chapter 5 FOUNDATION. 2010, The McGraw-Hill Companies, Inc. 2010, The McGraw-Hill Companies, Inc.


Integral Horsepower DC Motor & Generator Application Data CA608D

FLEXIDYNE PH Couplings

INSTALLATION, OPERATION AND CARE OF INTEGRAL HORSEPOWER INDUCTION MOTORS ( FRAMES) NAVY A-C MOTORS

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications

Table 1. Lubrication Guide

Electric Motor. Owner s Manual

Energy Saving Three Phase Motors

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

DATA SHEET. Three Phase Induction Motor - Squirrel Cage. Customer : Product code : : W22 NEMA Premium Efficiency Three-Phase

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base

SIGNAL WORDS QUALIFIED PERSON

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES

RVS-AX Instruction Manual

ELECTRIC MOTOR. Owner s Manual

PERFORMANCE - DELTA CONNECTION LOAD HP AMPERES RPM % % SPEED TORQUE - WYE / DELTA CONNECTION RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT 61 / 219

SECTION GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT

SUBMERSIBLE PUMPS DRAINER SUMP/EFFLUENT

PERFORMANCE DATA 3-PHASE INDUCTION MOTOR

Quick Engineering Facts Decimal Metric

PERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE VOLT CONNECTION(S). IF OTHER VOLTAGE CONNECTIONS ARE AVAILABLE, THE AMPERES WILL

Integral Horsepower AC Induction Motors ODP, WPI, WPII Enclosure TEFC Enclosure Explosion Proof

PRIMELINE. Induction Generator. Now Introducing Single Bearing Designs. Simple, Reliable Power For Wind or Engine Driven Applications

5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA MG1 (2003) Part 31,

AC Immersible Type Continuous In Air Motors Frame VAC and less Installation & Operating Manual

Integral Horsepower AC Induction Motors ODP, WPI, WPII Enclosure TEFC Enclosure Explosion Proof Installation & Operating Manual

IMPORTANT! READ BEFORE PROCEEDING! PAF Axial Propeller Fans

MAIN ELECTRIC MOTOR 900 HP 4000 V 60 HZ MAKE: RELIANCE ELECTRIC

SOLSTART Instruction Manual

Instruction Manual for FLEXIDYNE Couplings Sizes 9C and 11C

INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For THREE-PHASE INDUCTION MOTORS TYPE HJN / HJA

Installation, Operation And Maintenance of. AC and DC Mine Motors

Product Information Packet EM4410T-4 125HP,1785RPM,3PH,60HZ,444T,TEFC,F1

IMPORTANT! READ BEFORE PROCEEDING! PHR Axial Flow Hooded Roof Ventilators

INTER PLANT STANDARD STEEL INDUSTRY. Corresponding IS does not exist

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

Product Information Packet VM HP,1725RPM,3PH,60HZ,56C,3413M,TEFC,F1

VEM motors Thurm GmbH

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 92

Product Information Packet EM4313T 75HP,3550RPM,3PH,60HZ,365TS,1464M,TEFC,F

Starting of Induction Motors

Eclipse Hermetic Gas Boosters

DODGE No. 9D FLEXIDYNE Drive

DOCUMENTATION PACKAGE

DOCUMENTATION PACKAGE

Integral Horsepower AC Induction Motors Installation & Operating Manual

DATA SHEET CP MOTORIZED PUMP UNITS 3CP1120, 3CP1130, 3CP1140 5CP2140WCS, 5CP2150W

WELDING FUME EXHAUSTERS & ARMS

FAN ENGINEERING. Application Guide for Selecting AC Motors Capable of Overcoming Fan Inertia ( ) 2

Medium Voltage Induction Motors. 21-L Series New High Efficiency Design for High Capacity Applications 450 kw 18,500 kw (600 HP 25,000 HP)

Full Voltage Starting (Number of Starts):

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

THREE PHASE INDUCTION MOTORS

Product Information Packet ECP4410T-4 125HP,1785RPM,3PH,60HZ,444T,A44076M,TEFC

Product Information Packet EM3611T 3HP,1760RPM,3PH,60HZ,182T,3632M,TEFC,F1

Transcription:

ISSUED TYPE OUTPUT HP KW 10 7.5 8/15/2014 AEHH8N POLE 4 FRAME SIZE 215T PERFORMANCE DA 3-PHASE INDUCTION MOTOR NAMEPLE INFORMION RED INS. NEMA AGE HZ AMBIENT CLASS DESIGN 230/460 60 40 o C F B TIME RING CONT. ENCLOSURE CALOG# TEFC EP0104 SERVICE FACTOR 1.15 HZ 3~60 HP 0.0013~10 VARIABLE TORQUE RPM 90~1800 VARIABLE FREQUENCY DRIVE SERVICE TORQUE (lb-ft) 0.076~29.92 OHMS/PHASE EQUIVALENT WYE CIRCUIT ( RED OPERING TEMPERURE 25 o C) R1 R2 X1 X2 0.5301 0.6748 1.849 2.5705 X m 77.076 HZ 6~60 CONSTANT TORQUE CONSTANT HORSEPOWER TORQUE TORQUE HP RPM HZ HP RPM (lb-ft) (lb-ft) 1~10 180~1800 29.92 60~120 10 1800~3600 29.92~14.96 FULL LOAD RPM 1755 EFFICIENCY TYPICAL PERFORMANCE POWER FACTOR FULL LOAD 3/4 LOAD 1/2 LOAD FULL LOAD 3/4 LOAD 1/2 LOAD MIN.% NOM.% % % % % % 90.2 91.7 91 91 88 84 75.5 SOUND PRESSURE LEVEL @ 3 FT Db(A) 60 NO LOAD CURRENTS FULL LOAD 208 230 460 208 230 6.17 6.74 3.37 25.70 23.30 LOCKED ROTOR 460 208 230 460 11.60 146.5 162.0 81 NEMA KVA CODE LETTER H SAFE STALL TIME IN SECONDS COLD HOT 40 28 TORQUE INERTIA ACCEL TIME (DOL) ALLOWABLE STARTS PER HOUR FULL LOAD (lb-ft) LOCKED ROTOR %FLT PULL UP %FLT BREAK DOWN %FLT 29.92 250 145 260 ROTOR WR 2 (lb-ft 2 ) NEMA LOAD WK 2 (lb-ft 2 ) 1.082 51 MAX ALLOWABLE WK 2 (lb-ft 2 ) 175 NEMA LOAD WK 2 Sec 4.31 MAX ALLOWABLE WK 2 Sec 14.58 COLD 2 HOT 1 APPROVED: M. PRER DRAWING NO. 31057EP0104 REVISION: 1

DE: June 22, 2005 CONNECTION DIAGRAM CALOG NO.: EP0104 SCHEMIC - Δ / Y CONNECTION ACROSS THE LINE CONNECTION LINE 230 CONNECTION LINE 460 CONNECTION WYE START-DELTA RUN CONNECTION LINE LINE LINE LINE 230 START 230 RUN 460 START 460 RUN DWG NO. DAC-1565-4

INSTALLION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512

RECEIVING 1. Check nameplate data. 2. Check whether any damage has occurred during transportation. 3. After removal of shaft clamp, turn shaft by hand to check that it turns freely. 4. If motor is to be reshipped (alone or installed to another piece of equipment) the shaft must again be clamped to prevent axial movement. Note: Remove the bearing clamp before turning the shaft on 284T-449TZ frame motors. WARNING THE FOLLOWING SAFETY PRECAUTIONS MUST BE OBSERVED: 1. Electric rotating machinery and high voltage can cause serious or fatal injury if improperly installed, operated or maintained. Responsible personnel should be familiarized with NEMA MG-1; Safety Standards for Construction and Guide Selection. Installation and Use of Electric Motors and Generators; National Electric Code and all local safety requirements. 2. When servicing, all power sources to the motor and to the accessory devices should be de-energized and disconnected and all rotating parts should be at standstill. 3. Lifting means, when supplied, are intended for lifting the motor only. When two lifting devices are supplied with the motor a dual chain must be used. 4. Suitable protection must be used when working near machinery with high noise levels. 5. Safeguard or protective devices must not be by-passed or rendered inoperative. 6. The frame of this machine must be grounded in accordance with the National Electric Code and applicable local codes. 7. A suitable enclosure should be provided to prevent access to the motor by other than authorized personnel. Extra caution should be observed around motors that are automatically or have automatic re-setting relays as they may restart unexpectedly. 8. Shaft key must be fully captive or removed before motor is started. 9. Provide proper safeguards for personnel against possible failure of motor-mounted brake, particularly on applications involving overhauling loads. 10. Explosion proof motors are constructed to comply with the label service procedure manual, repair of these motors must be made by TECO-Westinghouse Motor Company or U/L listed service center in order to maintain U/L listing. LOCION 1. Drip-proof motors are intended for use where atmosphere is relatively clean, dry, well ventilated and non-corrosive. 2. Totally enclosed motors may be installed where dirt, moisture, or dust are present and in outdoor locations. 3. Explosion-proof motors are built for use in hazardous locations as indicated by Underwriters label on the motor. 4. Chemical duty enclosed motors are designed for installation in high corrosion or excessive moisture locations. Note: in all cases, no surrounding structure should obstruct normal flow or ventilating air through or over the motor.

MOUNTING 1. Mount motor securely on a firm, flat base. All ball bearing normal thrust motors up to and including 256T frame size may be side-wall or ceiling mounted; all others check nearest TECO-Westinghouse office for mounting recommendations. 2. Align motor accurately, using a flexible coupling if possible. For drive recommendations, consult with drive or equipment manufacturer, or TECO-Westinghouse. 3. Mounting bolts must be carefully tightened to prevent changes in alignment and possible damage to the equipment. The recommended tightening torque s for medium carbon steel bolts, identified by three radial lines at 120 degrees on the head, are: Bolt Size Recommended Torque (Ft-lb.) Minimum Maximum 2/8 25 37 1/2 60 90 5/8 120 180 3/4 210 320 4. V-belts Sheave Pitch Diameters should not be less than those shown in Table 1 (NEMA recommended values) 5. Tighten belts only enough to prevent slippage. Belt speed should not exceed 5000 ft. per min. TABLE 1. V-Belt Sheave Pitch Diameters (MG1-14.42) Horsepower at Frame Synchronous Speed, RPM Number 3600 1800 1200 900 Conventional A, B, C, D AND E Minimum Pitch Diameter *Maximum Width V-Belt Sheave Narrow 3V, 5V, AND 8V Minimum Outside Diameter **Maximum Width 143T 1.5 1.75.5 2.2 4.25 2.2 2.25 145T 2-3 1.5-2 1.75 2.4 4.25 2.4 2.25 182T 3 3 1.5 1 2.4 5.25 2.4 2.75 182T 5......... 2.6 5.25 2.4 2.75 184T...... 2 1.5 2.4 5.25 2.4 2.75 184T 5......... 2.6 5.25 2.4 2.75 184T 7.5 5...... 3.0 5.25 3.0 2.75 213T 7.5-10 7.5 3 2 3.0 6.5 3.0 3.375 215T 10... 5 3 3.0 6.5 3.0 3.375 215T 15 10...... 3.8 6.5 3.8 3.375 254T 15... 7.5 5 3.8 7.75 3.8 4 254T 20 15...... 4.4 7.75 4.4 4 256T 20-25... 10 7.5 4.4 7.75 4.4 4 256T... 20...... 4.6 7.75 4.4 4 284T...... 15 10 4.6 9 4.4 4.625 284T... 25...... 5.0 9 4.4 4.625 286T... 30 20 15 5.4 9 5.2 4.625

TABLE 1. V-Belt Sheave Pitch Diameters (MG1-14.42) Horsepower at Frame Synchronous Speed, RPM Number 3600 1800 1200 900 Conventional A, B, C, D AND E Minimum Pitch Diameter V-Belt Sheave *Maximum Width Narrow 3V, 5V, AND 8V Minimum Outside Diameter **Maximum Width 324T... 40 25 20 6.0 10.25 6.0 5.25 326T... 50 30 25 6.8 10.25 6.8 5.25 364T...... 40 30 6.8 11.5 6.8 5 364T... 60...... 7.4 11.5 7.4 5.785 365T...... 50 40 8.2 11.5 8.2 5.785 365T... 75...... 9.0 11.5 8.6 5.785 404T...... 60... 9.0 14.25 8.0 7.25 404T......... 50 9.0 14.25 8.4 7.25 404T... 100...... 10.0 14.25 8.6 7.25 405T...... 75 60 10.0 14.25 10.0 7.25 405T... 100...... 10.0 14.25 8.6 7.25 405T... 125...... 11.5 14.25 10.5 7.25 444T...... 100... 11.0 16.75 10.0 8.5 444T......... 75 10.5 16.75 9.5 8.5 444T... 125...... 11.0 16.75 9.5 8.5 444T... 150......... 16.75 10.5 8.5 445T...... 125... 12.5 16.75 12.0 8.5 445T......... 100 12.5 16.75 12.0 8.5 445T... 150......... 16.75 10.5 8.5 *Max. Sheave width = 2(N-W) -.25 **Max Sheave width = N-W ***Sheave ratios grater than 5:1 and center-to-center distance less than the diameter of the large sheave should be referred to TECO-Westinghouse. POWER SUPPLY & CONNECTIONS 1. Wiring of motor and control, overload protection and grounding should be in accordance with National Electrical Code and all local safety requirements. 2. Nameplate voltage and frequency should agree with power supply. Motor will operate satisfactorily on line voltage within ±10% of nameplate voltage; or frequency with ±5% and with a combined variation not to exceed ±10%. 230-volt motors can be used on 208-volt network systems, but with slightly modified performance characteristics as shown on the nameplate. 3. Dual voltage and single voltage motors can be connected for the desired voltage by following connection diagram shown on the nameplate or inside of the conduit box. 4. All Explosion Proof motors have Temperature Limiting Devices in the motor enclosure to prevent excessive external surface temperature of the motor in accordance with U/L standards. Terminals of thermal protectors (P1 & P2) should be connected to the motor control equipment, according to the connection diagram inside of the conduit box. 5. Standard connection diagram for three phase, not thermally protected, dual rotation motors are shown in diagrams A through E. (Note: To change rotation, Interchange any two line leads)

*Important: For Part Winding Start, M2 contactor should be closed within two (2) seconds after M1 contactor is closed. Only 4 pole and above (e.g., 6P, 8P...) motors are satisfactory for Part Winding Start at low voltage. START UP 1. Disconnect load and start motor. Check direction of rotation. If rotation must be changed, ALLOW THE MOTOR TO STOP COMPLETLEY. Interchange any two leads of a three-phase motor. 2. Connect load. The motor should start quickly and run smoothly. If no, shut power off at once. Recheck the assembly including all connections before restarting. 3. If excessive vibration is noted, check for loose mounting bolts too flexible motor support structure or transmitted vibration from adjacent machinery. Periodic vibration checks should be made; foundations often settle. 4. Operate under load for short period of time and check operating current against nameplate. TESTING If the motor has been in storage for an extensive period or has been subjected to adverse moisture conditions, it is best to check the insulation resistance of the stator winding with a megometer. Depending on the length and conditions of storage it may be necessary to regrease or change rusted bearings. If the resistance is lower than one megohm the windings should be dried in one of the following two ways: 1. Bake in oven at temperatures not exceeding 194 F until insulation resistance becomes constant. 2. With rotor locked, apply low voltage and gradually increase the current through windings until temperature measured with a thermometer reaches 194 F. Do not exceed this temperature.

MAINTENANCE INSPECTION Inspect motor at regular intervals. Keep motor clean and ventilation openings clear. LUBRICION 1. Frame 143T-256T: Double shielded and pre-lubricated ball-bearing motors without grease fittings and don t need re-lubrication, except on MAX-E1 and MAX-E2 products which have re-greasable features. 2. Frames 280TS, 320-449TZ(TS): Motors having grease fittings and grease discharge devices at brackets. Motors are shipped with grease for initial running. It is necessary to re-lubricate anti-friction bearing motors periodically, depending on size and type of service. See Table 2 to provide maximum bearing life. Excessive or too frequent lubrication may damage the motor. TABLE 2 Horsepower Standard Conditions Severe Conditions Extreme Conditions 1 Thru 30 Hp, 1800 rpm and below 7 years 3 years 180 days 40 Thru 75 Hp, 1800 rpm and below 210 days 70 days 30 days 100 Thru 150 Hp, 1800 rpm and below 90 days 30 days 15 days 1 Thru 20 Hp, 3600 rpm 5 years 2 years 90 days 25 Thru 75 Hp, 3600 rpm 180 days 60 days 30 days 100 Thru 150 Hp, 3600 rpm 90 days 30 days 15 days Note: A. Standard conditions: 8 hours operation per day, normal or light loading, clear and 40 C ambient conditions. B. Severe conditions: 24-hour operation per day or light shock loading, vibration or in dirty or dusty conditions. C. Extreme conditions: With heavy shock loading or vibration or dusty conditions. D. For double shielded bearings, above data (lubrication frequency) means that the bearing must be replaced. 3. Be sure fittings are clean and free from dirt. Using a low-pressure grease gun, pump in the recommended grease until new grease appears at grease discharge hole. 4. Use the POLYUREA grease unless special grease is specified on the nameplate. 5. If re-lubrication is to be performed with the motor running, stay clear of rotating parts. After re-greasing, allow the motor to run for ten to thirty minutes.

RENEWAL PARTS 1. Use only genuine TECO-Westinghouse renewal parts or as recommended by TECO- Westinghouse Motor Company. 2. When you order renewal parts please specify complete information to TECO-Westinghouse office/agent such as type, frame no., poles, horsepower, voltage, series no., quantity, etc. FOR FURTHER INFORMION PLEASE CONTACT TECO-WESTINGHOUSE MOTOR COMPANY Round Rock, TX 800-873-8326