Power Supplies. Series FLEX Power Supplies...P2 Technical Information & Dimensions (Online)...P5. ADEL Power Supplies

Similar documents
CBI All in One DC UPS Power Solutions

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

INDUSTRIAL POWER SUPPLIES SFL-SERIES

All In one uninterruptible power supply solutions

SHORT-FORM DATA MARKINGS

Power Supplies. SDN-C Compact DIN Rail Series

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

SHORT-FORM DATA MARKINGS

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

Phoenix Inverter

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

DC/DC converters - MINI-PS DC/ 5-15DC/

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

1 Phase electronic contactor (SC 1)

C B. Operating up to 5000m altitude 5 year product warranty Models

Industrial Power Supplies

PEL power supplies. 24 Vdc 18 Vdc 12 Vdc SWITCHED MODE POWER SUPPLIES/ PEL SERIES

Electronic Circuit Breaker ESS20-0..

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

1606-XLE240E 24V,10A Single Phase Input

Electronic Circuit Breaker ESS20

Efficiency Model dependant 86 ~ 88% Isolation. Isolation Cap. Switching Freq. Safety. Case Material Base Material Potting.

Glossary/Technical appendix

Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester. Charge & Testing. Integrated Electronic Solutions

1606-XLE240EN 24V,10A Single Phase Input

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Series L9 UL-489 Miniature Circuit Breakers

MD60 Series 60W DINergy Power Supply

CS5.241, CS5.241-C1, CS5.241-S1

DC POWER SUPPLY SYSTEMS

MODEL SELECTION TABLE Open Frame Models. MODEL SELECTION TABLE U-Chassis Models. MODEL SELECTION TABLE Enclosed Models

SHORT-FORM DATA MARKINGS

TDK-Lambda ZWS240BP/A SPECIFICATIONS

POWER SUPPLY CS5.241-S1 CS5.244

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Switching Power Supplies

POWER SUPPLY CS S1 CS10.481

CB Type Intelligent Battery Chargers

RWS50B RWS100B RWS150B RWS300B RWS600B

QS20.241, QS C1

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

2W, Low Cost DIP, Dual Output DC/DC Converters

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES*

Installation Instructions

SOLSTART Instruction Manual

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

Unit/Comments. %; Equal Output Loads %; Equal Output Loads Full Load

CB Type Intelligent Battery Chargers

Series L9 UL489 Miniature Circuit Breakers

Uninterruptible Power Supplies

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

POWER SUPPLY SHORT-FORM DATA MAJOR AGENCY APPROVALS

Open Frame Power Supplies

Fuse holders and fuses

Uninterruptible power supplies (UPS)

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

QUINT-PS/24DC/24DC/20

1.1 Caution Statements

SHORT-FORM DATA MARKINGS

QUINT-PS/24DC/48DC/ 5

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

Power Supplies PSS Series

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

SECTION DC POWER SUPPLY/BATTERY CHARGER

Bulletin 1606 Switched Mode Power Supplies

Lockout Hysteresis Voltage VDC Maximum Input Current Vin=18V, 100% Load A

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

RVS-AX Instruction Manual

QUINT-PS/24DC/24DC/10

D R C- 4 0 s e r i e s

Power Supplies. 11/2 Introduction

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

Maximum Input Current Vin=18V, 100% Load A Vin=24V ma No-Load Input Current

Solid State Relays contactor with Integrated Fuse Type RGC1F

Bulletin 1489 Circuit Breakers. Selection Guide

Thermal Circuit Breaker 3120-F...

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

DIN Rail Power Supplies

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

Application example of a motor controlled by MCD100 and protected by a circuit breaker

Technical Information

Thermal Overcurrent Circuit Breaker 3120-F...

Transcription:

ower Supplies Series...2 Technical Information & Dimensions (Online)...5 ADEL ower Supplies 1

Flexible Switching ower Supplies Sprecher + Schuh is proud to bring you a Flexible ower Supply from the best in AC to DC power supplies, Adel System. High Quality AC to DC power with power boost up to 15% of rated Output to 6ºC 3-Year Warranty Solutions for ower Supply Continuity The FLEXline DC ower Supplies offer more power and flexibility for all your power needs. FLEX units are power rated from 1 to 15%, have a voltage input from 115V to 5V, and three modes of output circuit protection. The extremely compact housings offer a variety of features. Unparalleled Benefits ADEL system ower Supplies offer unparalleled benefits in the industry: High quality AC to DC power boost with up to 15% of rated output to 6ºC 1- and 2-phase input from 23V to 5V AC eliminates the need for control transformers Hiccup, Manual Reset and Continuous Output protection modes Operating temperature range of -25/+7ºC Metal Case I 2 provides excellent heat dissipation Built-in overload protection LED status indicator for all models Internally fused for short-circuit protection Easy Installation, DIN Rail Mountable Three year warranty One Solution, Many Applications ADEL system ower Supplies can apply to numerous applications and industries: LC and Smart Relay power roximity Switches Light Curtains Textile & Robotic Machinery Material Handling Equipment Metal & Wood Working Freezers & Refrigerators Building Automation Air Cleaning Systems acking Equipment 2

"ower Good" Contacts Output (Load side) Enable arallel Connection Adjust Output 22 27 VDC LED Status "OK" Field selectable via factory supplied jumper Three Modes of rotection With the exception of FLEX624A, all Flex Models are field selectable via a factory supplied jumper for the three protection modes as described below. Automatic Restart This is the default factory setting of all FLEX units. In case of short-circuit or overloading, the output current is interrupted. The device tries again to re-establish output voltage and normal condition about every 2 seconds until the problem is cleared. Hiccup Manual Continuous Mode Restart Output (default) (C.O.) Set Voltage Selection - Slide switch in casing - Some models are automatic or bridge only Input (Input voltage) Manual Reset In case of short-circuit or overload, the output current is interrupted. In order to restart the output it is necessary to switch-off the input circuit for about 1 minute. This protection mode is particularly suggested in applications where safety procedures require that reset be carried out only by an authorized person. Continuous Output mode In case of short-circuit or overload, the output current is kept at high values with near zero voltage. In case of short circuit the current can reach up to 3 times the rated current at 6 C. This protection mode is used to meet the requirements of demanding loads such as motors, solenoid valves, lamps, LC with highly capacitive input circuits and other loads with marked transient overload behavior. FLEX624A is factory set to continuous output (C.O.) mode only. Manual Reset Continuous Output 3

Technical Information Flexible Switching Mode ower Supplies Input Voltage Input Voltage Output Output Amps ower Catalog Watts Good AC Selection VDC @4ºC @6ºC Contact ➎ Number ➍ rice Single hase 115 23 Automatic 36 72 2 ➊ 1.5 ➋ ~ FLEX624A 166 115/23 Selectable ➌ 96/12 5 4 FLEX924A 213 115/23 Selectable ➌ 12/18 24 7.5 5 FLEX1724A 35 115/23 Selectable ➌ 24/336 14 1 FLEX2824A 36 115/23 Bridge only ➏ 48/6 25 2 FLEX524A 827 Two hase 23/4 5 Selectable ➌ 96/12 5 4 FLEX924B 234 23/4 5 Selectable ➌ 12/18 24 7.5 5 FLEX1724B 386 23/4 5 Selectable ➌ 24/336 14 1 FLEX2824B 416 Three hase 4 5 Automatic 48 6 24 25 2 FLEX524B 583 3-Year Warranty Norms and certifications The CE mark in According to EMC 24/18/EC and the Low voltage directive 26/95/EC Electrical Safety According to UL58, UL file E38682, IEC/EN 695 (VDE 85) e EN 5178 (VDE 16) for assembling device. The unit must be installed according to IEC/EN 695. Input / Output separation: SELV EN695-1 and ELV EN 624-1. Double or reinforced insulation. EMC Immunity EN 61-4-2, EN 61-4-3, EN 61-4-4, EN 61-4-5, EN 61-4-6, EN 61-6-2 EMC Emission: EN 61-6-4, EN61-3-2 Standards Conformity EN 624-1 Safety of Electrical Equipment Machines ➊ 115V Amp Rating shown; 3A @ 23V (72 W) ➋ 115V Amp Rating shown; 2.5@ 23V @ 5ºC (6 W) ➌ Input voltage selectable via slide switch located below input terminals inside metal casing. ➍ With the exception of Flex624A, all models are capable of being set to hiccup mode, manual reset or Continuous mode via factory supplied jumper. ➎ The NO ower Good signal contact Closes when the output power is OK and Opens when the output voltage falls below 2V DC. ➏ For 115V input voltage jumper is required between "bridge only" terminals. 4

FLEX624A Input: single-phase 115 23 V AC Output: One output 24 V DC 5ºC Efficiency up to 85% Strong overload without switch-off up Flexible power continuity: 36 to 72 W Input Nominal Input Voltage (2 x Vac) 115 23 Vac Input Voltage range (Vac) 9 264 19 A 5 msec. Input Current (115 23 Vac) 1.7 A T 4 A External Fuse (recommended) 6 A (MCB curve B) Output Output Voltage (Vn) Factory Setting 3% 24 Vdc Start up with Strong Load (capacitive load) 5. µf Turn-On delay after applying mains voltage 1.5 sec. () Continuous Current at 24 V < 4 C (In) 2 A (115) 3 A (23) Continuous Current at 24 V < 5 C (In) 1.5 A (115) 2.5 A (23) ower Boost Current at 24 Vdc 5 C(In) 3.5A 3 min. Current. Overload 4Vdc (permanent) I = In 5 C x (1.8-2.2) Max current Short Circuit (Icc) 7 A Typ. 2 msec 8 mvpp Efficiency 85 % Over temperature rotection. Shut-down output and Short-circuit protection, Dissipation power load (W) 13, (typ. 35 Vdc) arallel connection Climatic Ambient Temperature operation -25 up to +7 C (>5 derating 2.5% C) Ambient Temperature Storage -4 up to +85 C 3 Vac Isolation Voltage (In / E) 165 Vac Isolation Voltage (Out / E) 5 Vac rotection Class (EN/IEC 6529) I 2 Reliability: MTBF IEC 6179 > 5. h ollution Degree Environment 2 rotection class I with E connected 5x12x5 mm.3 kg approx. Solid (mm 2 ) Stranded (mm 2 ) AWG Torque (NM) Stripped Length: Input:.2-2.5.2-2.5 24-14.5-.6 7 mm Output:.2-2.5.2-2.5 24-14.5-.6 7 mm 1-H 72W Output derating Curve Continuous Load % 16 14 12 1 8 6 4 2-1 1 2 3 4 5 6 7 C 28 24 2 16 12 8 4 Out Voltage UL File E38682 Technical Information "VDC ok" LED indicator Output Voltage vs. Output Current, typ. Continuou... 1 2 3 4 5 6 7 Load (A) 5

Technical Information FLEX924A Input: single-phase 115 / 23 V AC Output: One output 24 V DC 6ºC Efficiency up to 89% Strong overload without switch-off, up to 5% Flexible power continuity: 96 to 12 W "ower Good" Contact Selectable rotection Mode: Hiccup, & Restart after Main Input Nominal Input Voltage (2 x Vac) 115 / 23 Vac Manual select Input from 115 to 23 Input Voltage range (Vac) 9 135 (115) 17 264 (23) 36 A 5 msec. Input Current (115 23 Vac) 1.91.96 A T 4 A External Fuse (recommended) 1 A (MCB curve B) Output Output Voltage (Vn) Factory Setting ±3% 24 Vdc Start up with Strong Load (capacitive load) 5. µf Turn-On delay after applying mains voltage 1 sec. () Continuous Current at 24 V < 4 C (In) 5 A (permanent) Continuous Current at 24 V < 5 C (In) 4.5 A (permanent) Continuous Current at 24 V < 6 C (In) 4 A (permanent) ower Boost Current at 24 Vdc 6 C(In) In (6 C) x 1.5 3 min. Current. Overload ~ = 4Vdc (permanent) I = In 6 C x (1.8-2.2) 12 A ermanent : Mode Typ. 2 msec 8 mvpp Efficiency 89 % Over temperature rotection. Shut-down output and Dissipation power load (W) 15 (typ. 35 Vdc) arallel connection ower Good contact rating (EN6947.4.1): Max. DC1: 3VDC 1S; AC1: 6 VAC 1A Climatic Ambient Temperature operation -25 up to +7 C (>6 derating 2.5% C) Ambient Temperature Storage -4 up to +85 C 3 Vac Isolation Voltage (In / E) 165 Vac Isolation Voltage (Out / E) 5 Vac rotection Class (EN/IEC 6529) I 2 Reliability: MTBF IEC 6179 > 5. h ollution Degree Environment 2 rotection class I with E connected 55x11x15 mm.5 kg approx. Input:.2-2.5.2-2.5 24-14.5-.6 7 mm Output:.2-2.5.2-2.5 24-14.5-.6 7 mm 1-H 12W UL File E38682 6

FLEX1724A Input: single-phase 115 / 23 V AC Output: 24 V DC 6ºC Efficiency up to 89% Strong overload without switch-off, up to 5% Flexible power continuity: 12 to 18 W "ower Good" Contact Selectable rotection Mode: Hiccup, & Restart after Main Input Nominal Input Voltage (2 x Vac) Manual select Input from 115 to 23 115 / 23 Vac Input Voltage range (Vac) 9 135 (115) 17 264 (23) 36 A 5 msec. Input Current (115 23 Vac) 2.8 1.3 A T 4 A External Fuse (recommended) 1 A (MCB curve B) Output Output Voltage (Vn) Factory Setting ±3% 24 Vdc Start up with Strong Load (capacitive load) 5.mF Turn-On delay after applying mains voltage 1 sec. () Rated Current at 24 V < 4 C (In) 7.5 A (permanent) Rated Current at 24 V < 5 C (In) 6 A (permanent) Rated Current at 24 V < 6 C (In) 5 A (permanent) ower Boost Current at 24 V 6ºC(In) In (6ºC) x 1.5 3 min. Current. Overload ~ = 4Vdc (permanent) I = In 6 C x (1.8-2.2) 16A ermanent: mode Typ. 2 msec 8 mvpp Efficiency 89 % Over temperature rotection. Shut-down output and Dissipation power load (W) 22 (typ. 35 Vdc) arallel connection ower Good contact rating (EN6947.4.1): Max. DC1: 3VDC 1S; AC1: 6 VAC 1A Climatic Ambient Temperature operation -25 up to +7 C (>6 derating 2.5% C) Ambient Temperature Storage -4 up to +85 C 3 Vac Isolation Voltage (In / E) 165 Vac Isolation Voltage (Out / E) 5 Vac rotection Class (EN/IEC 6529) I 2 Reliability: MTBF IEC 6179 > 5. h ollution Degree Environment 2 rotection class I with E connected 55x11x15 mm.6 kg approx. Input:.2-2.5.2-2.5 24-14.5-.6 7 mm Output:.2-2.5.2-2.5 24-14.5-.6 7 mm 1-H 18W Technical Information Output derating Curve Continuous Load % 16 14 12 1 8 6 4 2-1 1 2 3 4 5 6 7 C Out Voltage UL File E38682 Output Voltage vs. Output Current, typ. 28 24 2 16 12 8 4 16; 5 1 15 2 Load (A) 7

FLEX2824A Input: single-phase 115 / 23 V AC Output: 24 V DC 6ºC Efficiency up to 89% Strong overload without switch-off, up to 5% Flexible power continuity: 24 to 336 W "ower Good" Contact Selectable rotection Mode: Hiccup, & Restart after Main Input Nominal Input Voltage (2 x Vac) Manual select Input from 115 to 23 115 / 23 Vac Input Voltage range (Vac) 9 135 (115) 17 264 (23) 42 A 5 msec. Input Current (115 23 Vac) 3.3 2.2 A T 6.3 A External Fuse (recommended) 16 A (MCB curve B) Output Output Voltage (Vn) Factory Setting ±3% 24 Vdc Start up with Strong Load (capacitive load) 5.mF Turn-On delay after applying mains voltage 1 sec. () Rated Current at 24 V < 4 C (In) 14 A (permanent) Rated Current at 24 V < 5 C (In) 12 A (permanent) Rated Current at 24 V < 6 C (In) 1 A (permanent) ower Boost Current at 24 V 6ºC(In) In (6ºC) x 1.5 3 min. Current. Overload ~ = 4Vdc (permanent) I = In 6 C x (1.8-2.2) 3A ermanent: mode Typ. 2 msec 8 mvpp Efficiency 89 % Over temperature rotection. Shut-down output and Dissipation power load (W) 42 (typ. 35 Vdc) arallel connection, "Easy arallel" ower Good contact rating (EN6947.4.1): Max. DC1: 3VDC 1S; AC1: 6 VAC 1A Climatic Ambient Temperature operation -25 up to +7 C (>6 derating 2.5% C) Ambient Temperature Storage -4 up to +85 C 3 Vac Isolation Voltage (In / E) 165 Vac Isolation Voltage (Out / E) 5 Vac rotection Class (EN/IEC 6529) I 2 Reliability: MTBF IEC 6179 > 5. h ollution Degree Environment 2 rotection class I with E connected 72x115x135 mm.65 kg approx. Input:.2-2.5.2-2.5 24-14.5-.6 7 mm Output:.2-2.5.2-2.5 24-14.5-.6 7 mm Signal:.2-2.5.2-2.5 24-14.5-.6 7 mm 1-H 336W % 16 14 12 1 8 6 4 2 Out Voltage UL File E38682 Technical Information Output derating Curve Continuous Load C -1 1 2 3 4 5 6 7 Output Voltage vs. Output Current, typ. 28 24 2 16 12 8 4 1 2 3 4 Load (A) 8

Technical Information FLEX524A Input: single-phase 115 / 23 V AC Output: 24 V DC 6ºC Efficiency up to 9% Strong overload without switch-off, up to 5% Flexible power continuity: 48 to 6 W "ower Good" Contact Selectable rotection Mode: Hiccup, & Restart after Main Input Nominal Input Voltage (2 x Vac) Bridge for 115V 115 / 23 Vac Input Voltage range (Vac) 9 135 (115) 17 264 (23) 8 A 5 msec. Input Current (115 23 Vac) 8 4.2 A T 1 A External Fuse (recommended) 16 A (MCB curve B) Output Output Voltage (Vn) Factory Setting ±3% 24 Vdc Start up with Strong Load (capacitive load) 5.mF Turn-On delay after applying mains voltage 1 sec. () Rated Current at 24 V < 4 C (In) 25 A (permanent) Rated Current at 24 V < 5 C (In) 22 A (permanent) Rated Current at 24 V < 6 C (In) 2 A (permanent) ower Boost Current at 24 V 6ºC(In) In (6ºC) x 1.5 3 min. Current. Overload ~ = 4Vdc (permanent) I = In 6 C x (1.8-2.2) 6A ermanent: mode Typ. 2 msec 8 mvpp Efficiency 9 % Over temperature rotection. Shut-down output and Dissipation power load (W) 62 (typ. 35 Vdc) arallel connection, "Easy arallel" ower Good contact rating (EN6947.4.1): Max. DC1: 3VDC 1S; AC1: 6 VAC 1A Climatic Ambient Temperature operation -25 up to +7 C (>6 derating 2.5% C) Ambient Temperature Storage -4 up to +85 C 3 Vac Isolation Voltage (In / E) 165 Vac Isolation Voltage (Out / E) 5 Vac rotection Class (EN/IEC 6529) I 2 Reliability: MTBF IEC 6179 > 5. h ollution Degree Environment 2 rotection class I with E connected 85x12x14 mm.75 kg approx. Input: 4. 6. 3-1.8-1. 7 mm Output: 4. 6. 3-1.8-1. 7 mm Signal:.2-2.5.2-2.5 24-14.5-.6 7 mm 1-H 6W UL File E38682 9

Technical Information FLEX924B Input: two-phase 23 / 4 5 V AC Output: 24 V DC 6ºC Efficiency up to 89% Strong overload without switch-off, up to 5% Flexible power continuity: 96 to 12 W "ower Good" Contact Selectable rotection Mode: Hiccup, & Restart after Main Input Nominal Input Voltage (2 x Vac) Manual select Input from 23 to 4-5 23 / 4 5 Vac Input Voltage range (Vac) 187 264 (23) 33 55 (4-5) 17 A 5 msec. Input Current (23/4 5 V AC) 1..58.46 A T 4 A External Fuse (recommended) 1 A (MCB curve B) Output Output Voltage (Vn) Factory Setting ±3% 24 Vdc Start up with Strong Load (capacitive load) 5.mF Turn-On delay after applying mains voltage 1 sec. () Rated Current at 24 V < 4 C (In) 5 A (permanent) Rated Current at 24 V < 5 C (In) 4.5 A (permanent) Rated Current at 24 V < 6 C (In) 4 A (permanent) ower Boost Current at 24 V 6ºC(In) In (6ºC) x 1.5 3 min. Current. Overload ~ = 4Vdc (permanent) I = In 6 C x (1.8-2.2) 12A ermanent: mode Typ. 2 msec 8 mvpp Efficiency 89 % Over temperature rotection. Shut-down output and Dissipation power load (W) 12 (typ. 35 Vdc) arallel connection, "Easy arallel" ower Good contact rating (EN6947.4.1): Max. DC1: 3VDC 1S; AC1: 6 VAC 1A Climatic Ambient Temperature operation -25 up to +7 C (>6 derating 2.5% C) Ambient Temperature Storage -4 up to +85 C 3 Vac Isolation Voltage (In / E) 165 Vac Isolation Voltage (Out / E) 5 Vac rotection Class (EN/IEC 6529) I 2 Reliability: MTBF IEC 6179 > 5. h ollution Degree Environment 2 rotection class I with E connected 55x11x15 mm.5 kg approx. Input:.2-2.5.2-2.5 24-14.5-.6 7 mm Output:.2-2.5.2-2.5 24-14.5-.6 7 mm 2-H 12W UL File E38682 1

FLEX1724B Input: two-phase 23 / 4 5 V AC Output: 24 V DC 6ºC Efficiency up to 89% Strong overload without switch-off, up to 5% Flexible power continuity: 12 to 18 W "ower Good" Contact Selectable rotection Mode: Hiccup, & Restart after Main Input Nominal Input Voltage (2 x Vac) Manual select Input from 23 to 4-5 23 / 4 5 Vac Input Voltage range (Vac) 187 264 (23) 33 55 (4-5) 28 A 5 msec. Input Current (23/4 5 V AC) 1.45 -.83 -.68 A T 4 A External Fuse (recommended) 1 A (MCB curve B) Output Output Voltage (Vn) Factory Setting ±3% 24 Vdc Start up with Strong Load (capacitive load) 5.mF Turn-On delay after applying mains voltage 1 sec. () Rated Current at 24 V < 4 C (In) 7.5 A (permanent) Rated Current at 24 V < 5 C (In) 6 A (permanent) Rated Current at 24 V < 6 C (In) 5 A (permanent) ower Boost Current at 24 V 6ºC(In) In (6ºC) x 1.5 3 min. Current. Overload ~ = 4Vdc (permanent) I = In 6 C x (1.8-2.2) 16A ermanent: mode Typ. 2 msec 8 mvpp Efficiency 89 % Over temperature rotection. Shut-down output and Dissipation power load (W) 22 (typ. 35 Vdc) arallel connection ower Good contact rating (EN6947.4.1): Max. DC1: 3VDC 1S; AC1: 6 VAC 1A Climatic Ambient Temperature operation -25 up to +7 C (>6 derating 2.5% C) Ambient Temperature Storage -4 up to +85 C 3 Vac Isolation Voltage (In / E) 165 Vac Isolation Voltage (Out / E) 5 Vac rotection Class (EN/IEC 6529) I 2 Reliability: MTBF IEC 6179 > 5. h ollution Degree Environment 2 rotection class I with E connected 55x11x15 mm.6 kg approx. Input:.2-2.5.2-2.5 24-14.5-.6 7 mm Output:.2-2.5.2-2.5 24-14.5-.6 7 mm 2-H 18W Technical Information Output derating Curve Continuous Load % 16 14 12 1 8 6 4 2-1 1 2 3 4 5 6 7 C Out Voltage UL File E38682 Output Voltage vs. Output Current, typ. 28 24 2 16 12 8 4 16; 5 1 15 2 Load (A) 11

FLEX2824B Input: two-phase 23 / 4 5 V AC Output: 24 V DC 6ºC Efficiency up to 89% Strong overload without switch-off, up to 5% Flexible power continuity: 24 to 336 W "ower Good" Contact Selectable rotection Mode: Hiccup, & Restart after Main Input Nominal Input Voltage (2 x Vac) Manual select Input from 23 to 4-5 23 / 4 5 Vac Input Voltage range (Vac) 187 264 (23) 33 55 (4-5) 34 A 5 msec. Input Current (23/4 5 V AC) 2.49-1.44-1.15 A T 4 A External Fuse (recommended) 16 A (MCB curve B) Output Output Voltage (Vn) Factory Setting ±3% 24 Vdc Start up with Strong Load (capacitive load) 5.mF Turn-On delay after applying mains voltage 1 sec. () Rated Current at 24 V < 4 C (In) 14 A (permanent) Rated Current at 24 V < 5 C (In) 12 A (permanent) Rated Current at 24 V < 6 C (In) 1 A (permanent) ower Boost Current at 24 V 6ºC(In) In (6ºC) x 1.5 3 min. Current. Overload ~ = 4Vdc (permanent) I = In 6 C x (1.8-2.2) 3A ermanent: mode Typ. 2 msec 8 mvpp Efficiency 89 % Over temperature rotection. Shut-down output and Dissipation power load (W) 4 (typ. 35 Vdc) arallel connection ower Good contact rating (EN6947.4.1): Max. DC1: 3VDC 1S; AC1: 6 VAC 1A Climatic Ambient Temperature operation -25 up to +7 C (>6 derating 2.5% C) Ambient Temperature Storage -4 up to +85 C 3 Vac Isolation Voltage (In / E) 165 Vac Isolation Voltage (Out / E) 5 Vac rotection Class (EN/IEC 6529) I 2 Reliability: MTBF IEC 6179 > 5. h ollution Degree Environment 2 rotection class I with E connected 72x115x135 mm.65 kg approx. Input:.2-2.5.2-2.5 24-14.5-.6 7 mm Output:.2-2.5.2-2.5 24-14.5-.6 7 mm Signal:.2-2.5.2-2.5 24-14.5-.6 7 mm 2-H 336W Technical Information Output derating Curve Continuous Load % 16 14 12 1 8 6 4 2-1 1 2 3 4 5 6 7 C Out Voltage UL File E38682 Output Voltage vs. Output Current, typ. 28 24 2 16 12 8 4 1 2 3 4 Load (A) 12

Technical Information FLEX524B Input: three-phase 4 5 V AC Output: 24 V DC 6ºC Efficiency up to 91% Strong overload without switch-off, up to 5% Flexible power continuity: 48 to 6 W "ower Good" Contact Selectable rotection Mode: Hiccup, & Restart after Main Input Nominal Input Voltage (3 x Vac) 4 5 Vac Input Voltage range (Vac) 33 55 35 A 5 msec. Input Current (4 5 V AC) 1.27-1.1 A T 6.3 A External Fuse (recommended) 16 A (MCB curve B) Output Output Voltage (Vn) Factory Setting ±3% 24 Vdc Start up with Strong Load (capacitive load) 5.mF Turn-On delay after applying mains voltage 1 sec. () Rated Current at 24 V < 4 C (In) 25 A (permanent) Rated Current at 24 V < 5 C (In) 22 A (permanent) Rated Current at 24 V < 6 C (In) 2 A (permanent) ower Boost Current at 24 V 6ºC(In) In (6ºC) x 1.5 3 min. Current. Overload ~ = 4Vdc (permanent) I = In 6 C x (1.8-2.2) 6A ermanent: mode Typ. 2 msec 8 mvpp Efficiency 91 % Over temperature rotection. Shut-down output and Dissipation power load (W) 54 (typ. 35 Vdc) arallel connection ower Good contact rating (EN6947.4.1): Max. DC1: 3VDC 1S; AC1: 6 VAC 1A Climatic Ambient Temperature operation -25 up to +7 C (>6 derating 2.5% C) Ambient Temperature Storage -4 up to +85 C 3 Vac Isolation Voltage (In / E) 165 Vac Isolation Voltage (Out / E) 5 Vac rotection Class (EN/IEC 6529) I 2 Reliability: MTBF IEC 6179 > 5. h ollution Degree Environment 2 rotection class I with E connected 85x12x14 mm.75 kg approx. Input: 4. 6. 3-1.8-1. 7 mm Output: 4. 6. 3-1.8-1. 7 mm Signal:.2-2.5.2-2.5 24-14.5-.6 7 mm 3-H 6W UL File E38682 13

Technical Information Dimensions Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. FLEX WIDTH HEIGHT DETH FLEX624A 5 (1.97) 12 (4.72) 5 (1.97) FLEX924A, 1724A FLEX924B, 1724B 55 (2.17) 11 (4.33) 15 (4.13) FLEX2824A & B 72 (2.83) 115 (4.53) 135 (5.31) FLEX524A & B 85 (3.35) 12 (4.72) 14 (5.51) Electrical Connection Input - Output power connection: Input: FLEXxxxxxA series 1 hase Switching ower Supplies L, N, E. FLEXxxxxxB series 1hase Switching ower Supplies L, N, E. FLEXxxxxxB series 2 hase Switching ower Supplies L1, L2, E. FLEX5xxB series 3 hase Switching ower Supplies L1, L2, L3, E. Output: 24 Vdc is made via the (+), (-). 1 hase L N E 1 hase L NE 2hase 3 hase Signaling: Red LED (DC OK) Status: Output voltage OK: Lights up permanently Switch OFF, in Overload and Short Circuit conditions Blink, in Overload and Short Circuit conditions Hiccup Mode Jumper Setting Manual Reset Continuous Mode arallel Connection, to Increase Output ower: Made parallel connection with same model of power supply to increase the output power. Adjust the output approximately to the same value (± 2mV) applying 1-2 A load to all devices output before connecting them in parallel. Easy parallel connections Jumper. In FLEX28xxX and FLEX5xxX for more power, you must change position of the jumper to enable parallel connection. In this mode you can put in parallel up to 4 power supply Serial Connection: a) It is possible to connect as many units in series as needed, providing the sum of the output voltage does not exceed 15Vdc. b) Voltages with a potential above 6Vdc are not SELV any more and can be dangerous. Such voltages must be installed with a protection against touching. c) For serial operation use power supplies of the same type. d) Grounding of the output is required when the sum of the output voltage is above 6Vdc. e) Keep an installation clearance of 15mm (left/right) between two power supplies and avoid installing the power supplies on top of each other. Note: Avoid return voltage (e.g. from a decelerating motor or battery) which is applied to the output terminals. 14