Issue Abbreviated MSP numbering system AUMA MATIC Types AM. Uncontrolled copy! EWH-25 GB-10. Quality Management System AUMA-Group

Similar documents
Issue Abbreviated SSP-numbering system AUMA SEMIPACT types SEM EWH-29 SHORT GB-01. Quality Management System AUMA-Group

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

ELECTRIC MULTI-TURN ACTUATORS for valve automation in the oil & gas industry with high torque requirements

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

Electric part-turn actuators

1/4 turn electric actuators (irreversible reducer with multi -turn electric actuator AUMA generation.2)

1/4 turn ACTELEC SG05.1 to SG12.1 (AUMA)

Electric Actuators Maximum in-lbs

Electric Actuators Maximum in-lbs

Part-turn actuators SQ 05.2 SQ 14.2/SQR 05.2 SQR 14.2 with actuator controls AUMA MATIC AM 01.1

1-3 MANUAL STARTERS EXERCISE OBJECTIVE. Examine and describe the operation of manual motor starters. DISCUSSION

CWM_N NEMA Rated Contactors

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

Electric multi-turn actuators

SELECTRIC, INC. Selectric (PX) Full Voltage Type Motor Control Panel Installation And Operation Manual

RVS-DN Digital Reduced Voltage Motor Starter

SELECTRIC, INC. Selectric (PA) Autotransformer Type Motor Control Panel Installation And Operation Manual

Controls and Instruments

For Operation in the Control Cabinet 3RW Soft Starters

Part-turn actuators SQEx 05.2 SQEx 14.2 SQREx 05.2 SQREx 14.2 with actuator controls AUMA MATIC AMExC 01.1

Multi-turn actuators. Product description

Delta Products VFD CP2000 Bypass Control Packages.

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Programmable Logic Controller. Mat Nor Mohamad

CK Range. Keeping the World Flowing. Spare Parts Manual. Modular Design Electric Valve Actuators

Multi-turn actuators SAEx 07.2 SAEx 16.2 SAREx 07.2 SAREx 16.2 with actuator controls AUMA MATIC BASIC AMBExC01.1

ABB Softstarter Benefits Charnchanok Thongprad

Exercise 1-3. Manual Starters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Direct-on-line (DOL) starters. Reversing starters

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (2 of 2) Lecture 6 Contactors and Motor Starters

Recommended spare parts and often used accessories

Components for EEx e Panels

Performance. Type NA006 NA009 NA015 NA019 NA028 NA038 NA050 NA060 NA080 NA100 NA150 NA200 NA250

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Air Circuit Breakers

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

MCD 200 Series Soft Starters

HVW701 HVAC Drive with By-Pass

Part-turn actuators SGExC 05.1 SGExC 12.1 AUMA NORM (without controls)

CTi Automation - Phone: Fax: Web:

Air Circuit Breakers

DEVICE STATE/BYPASSED FAILURE OVERLOAD

MCU/MCU+ 550(22) & 550(23) SERIES CONDENSING UNITS (Metal Lid)

ELECTRIC ACTUATORS. for industrial applications and civil vessels ELEKTRISCHE STELLANTRIEBE

Series A Electric Linear Actuators

RVS-DX Digital Reduced Voltage Motor Starter

ROBICON W120 enclosed drive

Industry Automation Control Components

Electric Actuator EQ Series

Technical Specification. RCS Electric Actuators with a ProfiBus Field Control and Communication Module

A Compact and Reliable Quarter-Turn Electric Actuator

Electric Actuator Options & Accessories

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

ECU1000 ELECTRONIC CONTROL UNIT

1.1 Caution Statements

ProMinent Pro M inent Sigma/ 3 Diaphragm Meter ing Pu mps. Diaphragm Rupture Warning System

3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008

Multi-turn actuators SAExC 07.1 SAExC 16.1 SARExC 07.1 SARExC 16.1 AUMA NORM (without controls)

F01 Electric Actuators

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

Induction Power Supplies

Series Village Lane Easley, SC Ph: (864) Fax: (864) Worm and Spur Gear Electric Actuators

3RW Soft Starters. General data. 6/4 Siemens LV

Motors Automation Energy Transmission & Distribution Coatings EDP11. Enclosed Drive Panel USA EDP11

MAQ Series Electric Actuator

PARKING LOT CONTROLLER WITH LOGIC & MAIN CONTACTOR

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Start-up instructions

Part-turn actuators SQEx 05.2 SQEx 14.2 SQREx 05.2 SQREx 14.2 with local controls AUMA SEMIPACT SEMExC 01.1

Recommended spare parts and often used accessories

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

AuCom - Soft Starters

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2008

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

* With I-Option card only (C. T. connection) Basic connections with isolated contacts

Actuator for power and water applications

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry.

12 Series Linear Electric Actuator Installation, Operation & Maintenance Manual

COMPLETE LISTING OF OPTIONS. Toggles, Lights

1/4 turn ACTELEC OA3 to BS100 (BERNARD)

TQ Series represents our devoted technology over 30 years of experience in the valve actuation, offering customer the reliable, quality assured, and

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase

Solid State Starters. Standard and Combination Packages. NEMA 4/ 12 Units are Designed for Crusher Applications

SECTION MOTOR CONTROL

MANUAL. MiniMax V / VK

THYRISTORS T2-2PH from 45A to 2700A Specifications Universal 2 Phase Thyristor Unit , March 2012

Features and Benefits. Control Features

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

High performance Vector Control. Ratings. System configuration

Power & Distribution Transformers

B BASIC HEAT TREATMENT CONSOLE

Multi-turn actuators SA 07.2 SA 16.2/SAR 07.2 SAR 16.2 with local control unit AUMA SEMIPACT SEM 01.1/SEM 02.1

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters

Instruction Manual. Q Series 2 Motor Control Modules - OEM

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Transcription:

Issue 2004-08-04 Abbreviated MSP numbering system Types AM Only for internal use EWH-25 GB-10 Distributor: Distributor to subsidiaries representatives according to separate list Uncontrolled copy! Issue 13 dated 2001-06-12 Dept. Name Date Reference issued PM Mr Rist checked AUM Actuators Inc. Mr Matthis checked EE Mr Th. Weber checked AA Mr Kempf

Page 1 of 18 Table of contents 1. Digit Housing 2. Digit Customer connections 3. Digit Type of motor 4. Digit Type of interface 5. Digit Input signals to interface board Input signals to positioner board 6. Digit Output signals from interface board Feedback (E2) to positioner board 7. Digit Input range for interface board Input range for positioner board 8. Digit - 9. Digit Power supply 10. Digit Motor controls 11. Digit Selector switch 12. Digit Pushbuttons and indication lights 13. Digit Heater and blinker transmitter 14. Digit Motor protection In general: Deviations to the regulations in EWH-01: - This specification is not released by AL-QW - In case of revisions single pages can be exchanged - The summary of changes to the previous issue is attached as appendix 1 - All pages of this procedure are informal with the auma logo - The procedure is copied according to the distributor - The document is not signed by SCK, SCM and WOF Notes: 1. The wiring diagrams MSP and the ordering codes are valid for the version AM 01.1 and AM 02.1 () AM Ex (C) 01.1 and AM Ex 02.1 ( Ex) AM FM 01.1 and AM FM 02.1 ( FM) 2. Specials which are required for certain projects/ plants are registered under the ordering codes XX.100 etc. (e.g. 41.100, 41.101 etc.) 1

Page 2 of 18 = 1. Digit: Housing Housing Wall Bracket XM connection XA connection 1 Water tight - Plug / Socket 3 Ex - Plug / Socket 5 Water tight Plug / Socket Plug / Socket 6 Water tight Plug / Socket and Terminals 8 Water tight Plug / Socket and Terminals Terminals Plug / Socket 9 Factory Mutual - Plug / Socket D ExIIC Plug / Socket, Wire Bung and Terminals Terminals E ExIIC - Terminals 2

Page 3 of 18 = 2. Digit: Customer connections 1 Plug / socket without torque switch bypass A Plug / socket with torque switch bypass, both directions 4 Terminals without torque switch bypass 0 Terminals with torque switch bypass, both directions 3 Terminals (explosion proof) without torque switch bypass 9 Special 2 Integral Circuit Breaker, plug / socket with torque switch bypass, both directions 7 Integral Disconnect Switch, plug / socket with torque switch bypass, both directions 3

Page 4 of 18 = 3. Digit: Type of motor 1 3-phase AC motors 3 Single phase motors type SK SG.1 actuator 7 Single phase motors type CSIR 230V (Leeson) Integral capacitors 8 Single-phase motors type PSC (ME and Leeson) Integral capacitors 9 Single-phase motors type CSIR 115V (Leeson) Integral capacitors E Single phase motors type SE SG.3 actuator 4

Page 5 of 18 = 4. Digit: Type of interface 0 Standard interface board 7 Positioner board - Profibus-DP or Modbus-RTU 6 Timer board 5

Page 6 of 18 = 5. Digit: Input signals to interface board K OPEN-STOP-CLOSE C OPEN-STOP-CLOSE/EMERGENCY-CLOSE (NC contact) EMERGENCY-CLOSED independent from selector switch position A OPEN-CLOSE STOP button not shown in wiring diagram D OPEN-STOP-CLOSE/EMERGENCY-OPEN (NC contact) EMERGENCY-OPEN independent from selector switch position 6

Page 7 of 18 = 5. Digit: Input signals to positioner board 0 E1 and E2 E1 = command signal, E2 = feedback signal Refer to digit 7 for input range 7

Page 8 of 18 = 6. Digit: Output signals from interface board C OPEN-CLOSE-LOCAL-REMOTE A OPEN-CLOSE Choose this for Timer Board 8

Page 9 of 18 6. Digit: Feedback signal (E2) to positioner 0 Potentiometer with no customer feedback or RWG for shared customer feedback. 0 Potentiometer to positioner. RWG for feedback to customer. Dual potentiometer with RWG 0 Potentiometer to positioner. Potentiometer for feedback to customer Dual potentiometer 9

Page 10 of 18 7. Digit: Input signals to interface board 3 24 Volt DC internal or external supply 5 110-125 V AC internal or external supply 10

Page 11 of 18 7. Digit: Input range for positioner board - Current Input (e.g., 4-20 ma) 1 Voltage Input (i.e., 0-5 V) 11

Page 12 of 18 8. Digit: - - Choose this for standard interface board or positioner board 1 Profibus-DP 2 Modbus-RTU 12

Page 13 of 18 9. Digit: Power supply - Standard, Interface Board 24 V DC / 24 V DC for customer Interface Board 115 V AC / 115 V AC for customer Positioner Board / no voltage for customer 1 Interface Board 24 V DC / 115 V AC for customer Positioner Board / 115 V AC for customer 2 Positioner Board / 24 V DC for remote command board, 24 V AC for customer 3 Interface Board 24 V DC / 24 V DC for control commands, 24 V AC for customer 13

Page 14 of 18 10. Digit: Motor controls A Thyristor unit (module) for 3-ph AC motors 208V 240V max. 0.37kW (0.5hp) 380V 500V max. 1.5kW (2hp) G Thyristor unit (4 single blocks) for 3-ph-AC motors 208V 240V max. 1.5kW (2hp) 380V 500V max. 5.5kW (7.5hp) D L Thyristor unit (2 single blocks) for 1-ph AC motors Main power connected to L1 and N (1 fuse on A21) Thyristor unit (2 single blocks) for 1-ph AC motors Main power connected to L1 and L2 (2 fuses on A21) ME/SE/SK motors: max. 0.37kW (0.5hp) Leeson PSC 230V motors: max. 0.75kW (1hp) Leeson PSC 110V motors: max. 0.75kW (1hp) ME/SE/SK motors: max. 0.37kW (0.5hp) Leeson PSC 230V motors: max. 0.75kW (1hp) F with contactors up to 7.5 kw 380 690V max. 7.5kW (10hp) 208 240V max. 3.0kW (4hp) H R W with contactors up to 7.5 kw, with auxiliary contacts - for each contactor 1 NO and 1 NC, wired to customer's plug/socket connector with contactors up to 7.5 kw, with auxiliary contacts - for each contactor 1 NO, wired to customer's plug/socket connector With contactors for 1-ph AC motors Main power connected to L1 and L2 380 690V max. 7.5kW (10hp) 208 240V max. 3.0kW (4hp) 380 690V max. 7.5kW (10hp) 208 240V max. 3.0kW (4hp) 14

Page 15 of 18 11. Digit: Selector Switch 0 No switch X No switch. Remote command board included. 1 Three position switch with no auxiliary contacts. Remote command board not included. 2 Three position switch with auxiliary contacts. Remote command board not included. 4 Three position switch with auxiliary contacts. Remote command board included. NO contact in both local and remote NO contact in both local and remote F G P H Three position switch with no auxiliary contacts. Reset function for PTC tripping device. Remote command board not included. Three position switch with auxiliary contacts. Reset function for PTC tripping device. Remote command board not included. Three position switch with auxiliary contacts. Reset function for PTC tripping device. Remote command board included. Two position switch with auxiliary contacts. Remote command board included. For Ex actuators For Ex actuators. NO contact in both local and remote For Ex actuators. NO contact in both local and remote NO contact in both local and remote J Two position switch with auxiliary contacts. NO contact in both local and remote 15

Page 16 of 18 12. Digit: Pushbuttons and indication lights 0 without pushbuttons and indication lights 7 pushbuttons OPEN, STOP, CLOSE without indication lights 8 pushbuttons OPEN, STOP, CLOSE indication lights OPEN: green, FAULT: red, CLOSE: yellow A J P pushbuttons OPEN, CLOSE, LOCK-OUT STOP indication lights OPEN: green, FAULT: red, CLOSE: yellow pushbuttons OPEN, STOP, CLOSE indication lights OPEN: red, FAULT: yellow, CLOSE: green pushbuttons OPEN, CLOSE, LOCK-OUT STOP indication lights OPEN: red, FAULT: yellow, CLOSE: green Not possible with thyristors Not possible with thyristors Q pushbuttons OPEN, CLOSE indication lights OPEN: green, FAULT: yellow, CLOSE: red S pushbuttons OPEN, CLOSE, LOCK-OUT STOP indication lights OPEN: green, FAULT: yellow, CLOSE: red Not possible with thyristors 16

Page 17 of 18 13. Digit: Heater and blinker transmitter E If None are required or if the following are needed: If Blinker Switch - not wired to customer connections If Control Unit Heater not powered by the customer If Motor Heater powered by customer H F T J Blinker Switch - wired to customer connections Control Unit Heater not powered by the customer Motor Heater not powered by the customer and Blinker Switch - not wired to customer connections Control Unit Heater not powered by the customer Motor Heater not powered by the customer and Blinker Switch - wired to customer connections Control Unit Heater not powered by the customer Motor Heater powered by customer Control Unit Heater powered by the customer No Blinker Switch 17

Page 18 of 18 14. Digit: Motor protection 1 Thermoswitch 2 Thermoswitch and thermal overload relay C PTC tripping device Mandatory for modulating Ex actuators with/without controls 18