OVERFILL PROTECTION WHILE TOP-LOADING RAILCAR OR TANK-TRUCK PHONE FAX: (8) -0 0 Mattox Road Kansas City, MO 0 www.civacon.com 80-0 BCU- 00HS-0 00KMLS-0 00RHS-00 SS Probe Tip Shown 00RKMLS-00 0-0 0-8x0 KEY PRODUCT LOADING STYLE PRODUCT # DESCRIPTION RACK MONITOR 80-XXX CANE PROBE (select ) OPEN LOADING CLOSED LOADING 00HS-0 00RHS-00 Optic (-) Rack Monitor with Ground Verification and Red & Green Indicator Lights. Available in 0 (-0) or 0 (-0) Volt Optic Cane Probe (Aluminum) 0" Standard Length with Universal Clamp, 0' Coiled Cord and -Pin Plug Optic Cane Probe (Stainless Steel) 0 Standard length with universal Clamp, 0 Coiled Cord and -Pin Plug 00KMLS-0 Optic Cane Probe (Aluminum) 0 Standard Length with Kamlok Coupler, 0 Coiled Cord and -Pin Plug 00RKMLS-00 Optic Cane Probe (Stainless Steel) 0" Standard Length with Kamlok Coupler, 0' Coiled Cord and -Pin Plug 0-0 0-8X0 OPTION BCU- Junction Box with -pin socket for Cane Probe (For use when Optional BCU- Bypass Authorizer Option is NOT planned) Junction Box with -pin socket for Cane Probe WITH Bypass Port for the 80 Monitor BCU- Overfill Bypass Authorizer Electronic Overfill Bypass Authorizer for 80 Optic Rack Monitors (Requires 0-8X0 Junction Box) NOTE: Does Not Bypass Ground Verification Function of 80 - ONLY Overfill Detection Function Ground Verification Connectors, Cables and Accessories continued on next page Copyright 0, OPW Fluid Transfer Group Printed in USA /
GROUND VERIFICATION (WITH OVERFILL) WHILE TOP-LOADING RAILCAR OR TANK-TRUCK PHONE FAX: (8) -0 0 Mattox Road Kansas City, MO 0 www.civacon.com 90-90 90-COIL 00-00 90-90 90-COIL 0-0 0-COIL 0-0 0-COIL (Two Shown) KEY PRODUCT CONNECTION STYLE PRODUCT # DESCRIPTION GROUND VERIFCATION CONNECTOR, CABLE & ASSEMBLIES (Rail Car & Tanker Use) (For Tankers with Dual Balls) 90-90 Ground Verification Clamp with 0' straight cord and 00-00 Junction Box 90-COIL Ground Verification Clamp with 0' coiled cord and 00-00 Junction Box 90-90 Ground Verification Dual Ball Plug with 0' straight cord and 00-00 Junction Box 90-COIL Ground Verification Dual Ball Plug with 0' coiled cord and 00-00 Junction Box ONLY Plain Cover, Non-Breakaway 00-00 Junction Box Assembly (Non-Breakaway), for use with any Ground Clamp & Cable Below REPLACEMENT CONNECTOR & CABLE ASSEMBLIES ACCESSORY ITEM APPLICATION NOTES: 0-0 Ground Verification Clamp with 0' straight cord 0-COIL Ground Verification Clamp with 0' coiled cord 0-0 Ground Verification Dual Ball with 0' straight cord 0-COIL Ground Verification Dual Ball Plug with 0' coiled cord Brass Ground Stud with Nut and Lockwasher. (Two Needed per Tanker - for Use with Dual Ball Connector). The Isolated Jaw Clamp Connection is typically used on rail cars and on tankers where no permanent ground connection point is provided.. The Dual Ball Connector can only used on tankers which are already equipped with dual brass ground studs per TTMA Recommended Practice RP with Balls spaced -/ (.mm) apart. Copyright 0, OPW Fluid Transfer Group Printed in USA /
BOTTOM-LOADING TRUCK RACK MONITOR SYSTEMS (TYPICAL EASTERN USA & EASTERN CANADA) PHONE FAX: (8) -0 0 Mattox Road Kansas City, MO 0 www.civacon.com 80 SERIES 880 SERIES 80 SERIES 90S-000 9S-000 90S-000 9S-000 9SR-9 9SR-9 RACK MONITOR PLUG &CABLE ASSEMBLIES INCLUDING (ALSO AVAILABLE SEPARATELY ON NEXT PAGE) USA - East of Rockies 80-80 Opti/Therm Rack Monitor with Ground Verification, Channel and Key Bypass - (USA Only) USA - East of Rockies 880 Opti/Therm Rack Monitor with Ground Verification, Channel, LED Display and Bypass - (Eastern USA Only) Canada - East of Rockies 880C Opti/Therm Rack Monitor with Ground Verification, 8 Channel, LED Display and Bypass - (Canada Only) USA - East of Rockies 80-80 Thermistor (-) Only Rack Monitor with Ground Verification, Channel and Key Bypass - (USA Only) Canada - East of Rockies 80C-80 Thermistor (-) Only Rack Monitor with Ground Verification, 8 Channel and Key Bypass - (Canada Only) With Green API Thermistor Standard Plug & Cables Standard Plug & Cables (Not for Use with 80 Series) With Plug & Cables 90S-000 Green, Locking Pin,Thermistor Plug with 0' 0-Conductor Orange Coiled Cable and 00 Junction Box Assembly 9S-000 Green, Locking Pin, Thermistor Plug with 0' 0-Conductor Orange Coiled Cable and 0T Breakaway Junction Box Assembly 90S-000 Blue, Locking Pin, Optic Plug with 0 0-Conductor Orange Coiled Cable and 00 Junction Box Assembly 9S-000 Blue, Locking Pin, Optic Plug with 0 0-Conductor Orange Coiled Cable and 0 Breakaway Junction Box Assembly 9SR-000 9SR-000 (Not for Use with 80 Series) Green, Locking Pin, Thermistor Plug with 0' 0-Conductor Orange Coiled Cable (with Shielded #9 ) and 0T Breakaway Junction Box Assembly (Plug & Cable Construction Equivalent to Scully P/N 88) Blue, Locking Pin, Optic Plug with 0' -Conductor Blue Coiled Cable (with Shielded #9 ) and 0 Breakaway Junction Box Assembly (Plug & Cable Construction Equivalent to Scully P/N 8) Replcement Plug and Cable Assemblies and Accessories continued on next page Copyright 0, OPW Fluid Transfer Group Printed in USA /
BOTTOM-LOADING TRUCK RACK PLUG & CABLES (TYPICAL EASTERN USA & EASTERN CANADA) PHONE FAX: (8) -0 0 Mattox Road Kansas City, MO 0 www.civacon.com 00-00 00C-00 0-0 00SR-00 0SR-0 00-00 0-0 00SR-00 0SR-0 00-00 0T-0 0-0 0-0 0-0 8-8 00-00 Thermistor Plug with 0' 0-Conductor Coiled Cable With Green API Thermistor Standard Plug 00C-00 Thermistor Plug with 0' 0-Conductor Coiled Cable (Canada only) 0-0 Thermistor Plug with 0' 0-Conductor Coiled Cable and -Pin Breakaway Connector (for use with 0T J-Box) 00SR-00 Thermistor Plug with 0' 0-Conductor Coiled Cable (with Shielded #9 - Replaces Scully P/N 88) PLUG AND CABLE Standard Plug 00-00 Optic Plug with 0' 0-Conductor Coiled Cable 0-0 Optic Plug with 0' 0-Conductor Coiled Cable and -Pin Breakaway Plug (for use with 0 J-Box) 00SR-00 Optic Plug with 0' -Conductor Blue Coiled Cable (with Shielded #9 - Replaces Scully P/N 8) 0SR-0 0SR-0 Thermistor Plug with 0' 0-Conductor Coiled Cable (with Shielded #9 ) and -Pin Breakaway Connector (use with 0T J-Box) Optic Plug with 0' -Conductor Blue Coiled Cable (with Shielded #9 ) and -Pin Breakaway Plug (use with 0 J-Box) Plain Cover, Non- Breakaway 00-00 Junction Box Assembly (Non-Breakaway), for use with any Non-Breakaway Optic Plug and Cables Above Thermistor Breakaway 0T-0 Junction Box Assembly (Optic Breakaway), with -Pin Socket for Thermistor Breakaway Plug and Cables Above Optiic Breakaway 0-0 Junction Box Assembly (Optic Breakaway), with -Pin Socket for Optic Breakaway Plug and Cables Above 0-0 Thermistor Plug Storage Hanger (Bolts to Rack Stucture) Plug Storage Hangers ACCESSORY ITEMS 0-0 Optic Plug Storage Hanger (Bolts to Rack Stucture) Rack Tester 8-8 Thermistor & Optic Rack Monitor Tester (Includes Ground Verifacction Test) Copyright 0, OPW Fluid Transfer Group Printed in USA /
BOTTOM-LOADING TRUCK RACK MONITORS (TYPICAL WESTERN USA & WESTERN CANADA) PHONE FAX: (8) -0 0 Mattox Road Kansas City, MO 0 www.civacon.com 80-0 80-0 90S-000 9S-000 9SR-9 BCU- RACK MONITOR PLUG & CABLE ASSEMBLIES INCLUDING (ALSO AVAILABLE SEPARATELY ON NEXT PAGE) USA & CANADA - West of Rockies USA & CANADA - West of Rockies Standard Plug & Cables With Plug & Cables 80-XXX 80-XXX Optic (-) Rack Monitor with Ground Verification, Red/Green Indicator Lights. Available in 0 (-0) or 0 (-0) Volt Optic (-) Rack Monitor with Ground Verification, Red/Green Indicator Lights. Available in 0 (-0) or 0 (-0) Volt. Including the 0-0 Junction Box and One BCU- Bypass Authorizer 90S-000 Blue, Locking Pin, Optic Plug with 0 0-Conductor Orange Coiled Cable and 00 Junction Box Assembly 9S-000 OPTION Overfill Bypass Authorizer BCU- 9SR-000 Blue, Locking Pin, Optic Plug with 0 0-Conductor Orange Coiled Cable and 0 Breakaway Junction Box Assembly Blue, Locking Pin, Optic Plug with 0' -Conductor Blue Coiled Cable (with Shielded #9 ) and 0 Breakaway Junction Box Assembly (Plug & Cable Construction Equivalent to Scully P/N 8) Electronic Overfill Bypass Authorizer for 80 Optic Rack Monitor (Requires 0-0 or 0-8x0 Junction Box) NOTE: Does Not Bypass Ground Verification Function of 80 - ONLY Overfill Detection Function Replcement Plug and Cable Assemblies and Accessories continued on next page Copyright 0, OPW Fluid Transfer Group Printed in USA /
BOTTOM-LOADING TRUCK RACK PLUG & CABLES (TYPICAL WESTERN USA & WESTERN CANADA) PHONE FAX: (8) -0 0 Mattox Road Kansas City, MO 0 www.civacon.com 00-00 0-0 0-0 0-8x0 00-00 0-0 00SR-00 0SR-0 0-0 8-8 PLUG AND CABLE Plain Cover, Non-Breakaway 00-00 Junction Box Assembly (Non-Breakaway), for use with any Non-Breakaway Optic Plug and Cables Below Optiic Breakaway 0-0 Junction Box Assembly (Optic Breakaway), with -Pin Socket for Optic Breakaway Plug and Cables Below With Bypass Port for BCU- Use (Order Plug & Cable Separately on Next Page) Standard Plug 0-0 0-8X0 Junction Box Assembly (Non-Breakaway) with BCU- Port, for use with any Non-Breakaway Optic Plug and Cables Below Junction Box Assembly (Optic Breakaway) with BCU- Port, with -Pin Socket for Optic Breakaway Plug and Cables Below 00-00 Optic Plug with 0' 0-Conductor Coiled Cable 0-0 Optic Plug with 0' 0-Conductor Coiled Cable and -Pin Breakaway Plug (for use with 0 J-Box) 00SR-00 Optic Plug with 0' -Conductor Blue Coiled Cable (with Shielded #9 - Replaces Scully P/N 8) 0SR-0 Optic Plug with 0' -Conductor Blue Coiled Cable (with Shielded #9 ) and -Pin Breakaway Plug (use with 0 J-Box) Plug Storage Hanger 0-0 Optic Plug Storage Hanger (Bolts to Rack Stucture) ACCESSORY ITEMS Rack Tester 8-8 Thermistor & Optic Rack Monitor Tester (Includes Ground Verifacction Test) Copyright 0, OPW Fluid Transfer Group Printed in USA /
GROUND VERIFICATION ONLY FOR TOP-LOADING RAILCAR OR TANK-TRUCK (OR OFF-LOADING) PHONE FAX: (8) -0 0 Mattox Road Kansas City, MO 0 www.civacon.com 800-0 90-90 90-COIL 00-00 90-90 90-COIL 0-0 0-COIL 0-0 0-COIL (Two Shown) KEY PRODUCT CONNECTION STYLE PRODUCT # DESCRIPTION GROUND VERIFICATION MONITOR 800-0 Ground Monitor, with Red/Green Status Lights Available in 0 or 0 Volt GROUND VERIFCATION CONNECTOR, CABLE & ASSEMBLIES REPLACEMENT CONNECTOR & CABLE ASSEMBLIES (Rail Car & Tanker Use) (For Tankers with Dual Balls) ACCESSORY ITEM APPLICATION NOTES: 90-90 Ground Verification Clamp with 0' straight cord and 00-00 Junction Box 90-COIL Ground Verification Clamp with 0' coiled cord and 00-00 Junction Box 90-90 Ground Verification Dual Ball Plug with 0' straight cord and 00-00 Junction Box 90-COIL Ground Verification Dual Ball Plug with 0' coiled cord and 00-00 Junction Box 0-0 Ground Verification Clamp with 0' straight cord 0-COIL Ground Verification Clamp with 0' coiled cord 0-0 Ground Verification Dual Ball with 0' straight cord 0-COIL Ground Verification Dual Ball Plug with 0' coiled cord Brass Ground Stud with Nut and Lockwasher. (Two Needed per Tanker - for Use with Dual Ball Connector). The Isolated Jaw Clamp Connection is typically used on rail cars and on tankers where no permanent ground connection point is provided.. The Dual Ball Connector can only used on tankers which are already equipped with dual brass ground studs per TTMA Recommended Practice RP with Balls spaced -/ (.mm) apart. Copyright 0, OPW Fluid Transfer Group Printed in USA / 8