OVERFILL PROTECTION WHILE TOP-LOADING RAILCAR OR TANK-TRUCK

Similar documents
OVERFILL PROTECTION & GROUND VERIFICATION TOP OR BOTTOM-LOADING RAILCAR AND TANK-TRUCK SYSTEMS, PARTS AND ACCESSORIES

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

8460SRC Replacement Chassis for Scully ST-6 and Biclops Monitors

Electronic Overfill Systems

O-Ring Swivel Joints

Single Point Overfill Prevention Control Monitor Model: ST-15C Series Technical Manual

INTELLITROL. scully. Scully s Intellitrol System. Intellitrol is a state of the art microprocessor based system that provides:

MULTIRACK GARNET. Optic / Thermistor Rack Control for Trucks MODEL 688S / 688D MANUAL. 688 Manual. Page 1. Printed in Canada

Dixon Bayco Supertanker Options

MULTIRACK. Optic / Thermistor Rack Control for Trucks MODEL 688S / 688D MANUAL. Printed in Canada

TANK TRUCK COMPONENTS CATALOGUE

Bottom Load Adaptors. API Adaptors 891 Series. API Bottom Loading Adaptor L

METERING REQUIREMENTS

Electronic Rack Equipment (240VAC FM Approved Models)

T195SV Vapor Recovery Vent

OPW Fluid Transfer Group Europe BV

TRANSPORT YOU CAN TRU S T PRODUCT CATALOG

ROMLink Installation Manual

KAMLOK AUTOLOK QUicK coupler SySTeMS

CPCS the U.S.A.

3500 Series & ProTrap Wiring Lead & Pup Trailer. P/N Rev. A

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.a June 1998

TANKER & STORAGE TANK PRODUCTS

Liquids Handling Control and Safety Systems. scully

PRODUCTS for PRESSURE RAILCARS For the Safe Loading, Transport and Unloading of Hazardous Materials

TMS Series MP46x Flex Probes* Installation Instructions

SAFETY SOCKET BOX. Note 8 3" MIN. 3" Max. (200 A)

ERD/ERC SERIES ELECTRIC FRYERS

FEEDMAX W/ SHUTTLE IJ SERIES. Parts Manual

MDT5N25 & MTD5N40 SERVICE PARTS

INSTALLATION AND SERVICE MANUAL FOR TURBO-CARB HIGH CAPACITY CARBONATOR

REPLACEMENT PARTS ILLUSTRATION

Mechanical Petroleum Tank-Truck Parts/Products Catalog

VAPOUR RECOVERY SYSTEM TO COMPLY EMISSION NORMS AT TALEGAON

Replacement Parts List FI 4009 & FI 4009C. SUPERSEDES: April 28, 2016 EFFECTIVE: October 18, 2016

ColVic Tanker Fittings

Sure Seal Tri-Set Rotary Process Valve

2500/2700 Series Gas Convection Oven

Spare Parts List. EW-3500-C and D EW-4200-C and D Marine Diesel Generators

INSTA-CHAIN 2009 CATALOG

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS

Electrostatic System Checks

OPW Emergency Safety Disconnector. Safety Breakaway Coupling Type NTS-PU Series (Pull-Away) Sizes 1-4 (DN25 DN100) Page 1

PARTS LIST. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

Instruction Manual. Q Series 2 Motor Control Modules - OEM

INSTRUCTION PLASTIC BATTERY BOX & CHARGER KIT

List prices are for individual parts See following pages for illustration of parts by number

EST Electrical Service Technician Answer Schedule

Total Front Access Wall Mount Fuse Panel Installation Guide. Document INS This manual covers the following part numbers

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters

NEW SYSTEM SPECIFICATIONS AND DIAGRAMS

Troubleshooting manual for Sanuvox R+ Air Purifier

92 Years of Manufacturing Heritage in the USA...

MDT5N25 & MTD5N40 SERVICE PARTS

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

SERVICE MANUAL / PARTS LIST

PARTS LIST CONTROL PANEL COMPONENTS

REAR SUSPENSION GROUP CONTENTS GENERAL DESCRIPTION TRAILING ARM REAR SUSPENSION DIAGNOSIS TOE CONTROL ARM...

TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL. TPM 001 Revision 0.1

IN-LINE HYDRAULIC FLOW TESTER

Specification Sheet Form Rev

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

TPM/GMT Panel Installation Guide

CFES365EB6 CFES365ES6

IN-LINE HYDRAULIC FLOW TESTER 75 GPM, 300 I/min.

IN-LINE HYDRAULIC FLOW TESTER 75 GPM, 300 I/min.

KEY PART # DESCRIPTION KEY PART # DESCRIPTION

MARINE ILLUSTRATED PARTS MANUAL

Lincolnweld AC-1000 POWER SOURCE

Automatic Powder Spray Gun Extruded Support Kits

Wine Cellar Adjustable Shelf

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

Specification Sheet Form Rev

Three-Way Metal Seated Ball Valve Type 21-M

Installing Power Components

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

Actuators for small valves

CATALOG OF REPLACEMENT PARTS

INSTA-CHAIN INTRODUCTION INTRODUCTION

Parts Reference. 5.1 Series Computerized Wheel Balancer FORM 5163

TS Series TS Series

STERILMATIC DIGITAL ELECTRIC STERILIZER PARTS AND SERVICE MANUAL

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2011

Sport Coil Springs Chysler 300C SRT-8 05 Dodge Charger SRT-8

Connector Systems Inc. SS-20 MACHINE MANUAL

KEY PART # DESCRIPTION KEY PART # DESCRIPTION

HEG HIGH VOLUME SERIES HOT WATER PRESSURE WASHERS

AMENDMENT ELECTRIC SERVICE MANUAL 2014

COMMERCIAL AUTOMATIC WASHER

Champion Series Zero-Turn Riders & Mower Decks

DR30D, DR30DI, DR30IH, DR30DH Range

Self-Stabilizing Hand Truck Table of Contents:

C C

Information on Aluminum Heater Core and/or Radiator Replacement # (Feb 24, 2005)

McQuay Climate Control Singer

Model Insulation Tester / Megohmmeter. User Manual

Sport Coil Springs Dodge Magnum, Chrysler 300C Dodge Challenger SRT Dodge Challenger R/T

E2000 SERIES ELECTRIC BAKE/ROAST DECK OVENS

NTC Thermistor Assemblies

DIAGNOSIS AND TESTING

Transcription:

OVERFILL PROTECTION WHILE TOP-LOADING RAILCAR OR TANK-TRUCK PHONE FAX: (8) -0 0 Mattox Road Kansas City, MO 0 www.civacon.com 80-0 BCU- 00HS-0 00KMLS-0 00RHS-00 SS Probe Tip Shown 00RKMLS-00 0-0 0-8x0 KEY PRODUCT LOADING STYLE PRODUCT # DESCRIPTION RACK MONITOR 80-XXX CANE PROBE (select ) OPEN LOADING CLOSED LOADING 00HS-0 00RHS-00 Optic (-) Rack Monitor with Ground Verification and Red & Green Indicator Lights. Available in 0 (-0) or 0 (-0) Volt Optic Cane Probe (Aluminum) 0" Standard Length with Universal Clamp, 0' Coiled Cord and -Pin Plug Optic Cane Probe (Stainless Steel) 0 Standard length with universal Clamp, 0 Coiled Cord and -Pin Plug 00KMLS-0 Optic Cane Probe (Aluminum) 0 Standard Length with Kamlok Coupler, 0 Coiled Cord and -Pin Plug 00RKMLS-00 Optic Cane Probe (Stainless Steel) 0" Standard Length with Kamlok Coupler, 0' Coiled Cord and -Pin Plug 0-0 0-8X0 OPTION BCU- Junction Box with -pin socket for Cane Probe (For use when Optional BCU- Bypass Authorizer Option is NOT planned) Junction Box with -pin socket for Cane Probe WITH Bypass Port for the 80 Monitor BCU- Overfill Bypass Authorizer Electronic Overfill Bypass Authorizer for 80 Optic Rack Monitors (Requires 0-8X0 Junction Box) NOTE: Does Not Bypass Ground Verification Function of 80 - ONLY Overfill Detection Function Ground Verification Connectors, Cables and Accessories continued on next page Copyright 0, OPW Fluid Transfer Group Printed in USA /

GROUND VERIFICATION (WITH OVERFILL) WHILE TOP-LOADING RAILCAR OR TANK-TRUCK PHONE FAX: (8) -0 0 Mattox Road Kansas City, MO 0 www.civacon.com 90-90 90-COIL 00-00 90-90 90-COIL 0-0 0-COIL 0-0 0-COIL (Two Shown) KEY PRODUCT CONNECTION STYLE PRODUCT # DESCRIPTION GROUND VERIFCATION CONNECTOR, CABLE & ASSEMBLIES (Rail Car & Tanker Use) (For Tankers with Dual Balls) 90-90 Ground Verification Clamp with 0' straight cord and 00-00 Junction Box 90-COIL Ground Verification Clamp with 0' coiled cord and 00-00 Junction Box 90-90 Ground Verification Dual Ball Plug with 0' straight cord and 00-00 Junction Box 90-COIL Ground Verification Dual Ball Plug with 0' coiled cord and 00-00 Junction Box ONLY Plain Cover, Non-Breakaway 00-00 Junction Box Assembly (Non-Breakaway), for use with any Ground Clamp & Cable Below REPLACEMENT CONNECTOR & CABLE ASSEMBLIES ACCESSORY ITEM APPLICATION NOTES: 0-0 Ground Verification Clamp with 0' straight cord 0-COIL Ground Verification Clamp with 0' coiled cord 0-0 Ground Verification Dual Ball with 0' straight cord 0-COIL Ground Verification Dual Ball Plug with 0' coiled cord Brass Ground Stud with Nut and Lockwasher. (Two Needed per Tanker - for Use with Dual Ball Connector). The Isolated Jaw Clamp Connection is typically used on rail cars and on tankers where no permanent ground connection point is provided.. The Dual Ball Connector can only used on tankers which are already equipped with dual brass ground studs per TTMA Recommended Practice RP with Balls spaced -/ (.mm) apart. Copyright 0, OPW Fluid Transfer Group Printed in USA /

BOTTOM-LOADING TRUCK RACK MONITOR SYSTEMS (TYPICAL EASTERN USA & EASTERN CANADA) PHONE FAX: (8) -0 0 Mattox Road Kansas City, MO 0 www.civacon.com 80 SERIES 880 SERIES 80 SERIES 90S-000 9S-000 90S-000 9S-000 9SR-9 9SR-9 RACK MONITOR PLUG &CABLE ASSEMBLIES INCLUDING (ALSO AVAILABLE SEPARATELY ON NEXT PAGE) USA - East of Rockies 80-80 Opti/Therm Rack Monitor with Ground Verification, Channel and Key Bypass - (USA Only) USA - East of Rockies 880 Opti/Therm Rack Monitor with Ground Verification, Channel, LED Display and Bypass - (Eastern USA Only) Canada - East of Rockies 880C Opti/Therm Rack Monitor with Ground Verification, 8 Channel, LED Display and Bypass - (Canada Only) USA - East of Rockies 80-80 Thermistor (-) Only Rack Monitor with Ground Verification, Channel and Key Bypass - (USA Only) Canada - East of Rockies 80C-80 Thermistor (-) Only Rack Monitor with Ground Verification, 8 Channel and Key Bypass - (Canada Only) With Green API Thermistor Standard Plug & Cables Standard Plug & Cables (Not for Use with 80 Series) With Plug & Cables 90S-000 Green, Locking Pin,Thermistor Plug with 0' 0-Conductor Orange Coiled Cable and 00 Junction Box Assembly 9S-000 Green, Locking Pin, Thermistor Plug with 0' 0-Conductor Orange Coiled Cable and 0T Breakaway Junction Box Assembly 90S-000 Blue, Locking Pin, Optic Plug with 0 0-Conductor Orange Coiled Cable and 00 Junction Box Assembly 9S-000 Blue, Locking Pin, Optic Plug with 0 0-Conductor Orange Coiled Cable and 0 Breakaway Junction Box Assembly 9SR-000 9SR-000 (Not for Use with 80 Series) Green, Locking Pin, Thermistor Plug with 0' 0-Conductor Orange Coiled Cable (with Shielded #9 ) and 0T Breakaway Junction Box Assembly (Plug & Cable Construction Equivalent to Scully P/N 88) Blue, Locking Pin, Optic Plug with 0' -Conductor Blue Coiled Cable (with Shielded #9 ) and 0 Breakaway Junction Box Assembly (Plug & Cable Construction Equivalent to Scully P/N 8) Replcement Plug and Cable Assemblies and Accessories continued on next page Copyright 0, OPW Fluid Transfer Group Printed in USA /

BOTTOM-LOADING TRUCK RACK PLUG & CABLES (TYPICAL EASTERN USA & EASTERN CANADA) PHONE FAX: (8) -0 0 Mattox Road Kansas City, MO 0 www.civacon.com 00-00 00C-00 0-0 00SR-00 0SR-0 00-00 0-0 00SR-00 0SR-0 00-00 0T-0 0-0 0-0 0-0 8-8 00-00 Thermistor Plug with 0' 0-Conductor Coiled Cable With Green API Thermistor Standard Plug 00C-00 Thermistor Plug with 0' 0-Conductor Coiled Cable (Canada only) 0-0 Thermistor Plug with 0' 0-Conductor Coiled Cable and -Pin Breakaway Connector (for use with 0T J-Box) 00SR-00 Thermistor Plug with 0' 0-Conductor Coiled Cable (with Shielded #9 - Replaces Scully P/N 88) PLUG AND CABLE Standard Plug 00-00 Optic Plug with 0' 0-Conductor Coiled Cable 0-0 Optic Plug with 0' 0-Conductor Coiled Cable and -Pin Breakaway Plug (for use with 0 J-Box) 00SR-00 Optic Plug with 0' -Conductor Blue Coiled Cable (with Shielded #9 - Replaces Scully P/N 8) 0SR-0 0SR-0 Thermistor Plug with 0' 0-Conductor Coiled Cable (with Shielded #9 ) and -Pin Breakaway Connector (use with 0T J-Box) Optic Plug with 0' -Conductor Blue Coiled Cable (with Shielded #9 ) and -Pin Breakaway Plug (use with 0 J-Box) Plain Cover, Non- Breakaway 00-00 Junction Box Assembly (Non-Breakaway), for use with any Non-Breakaway Optic Plug and Cables Above Thermistor Breakaway 0T-0 Junction Box Assembly (Optic Breakaway), with -Pin Socket for Thermistor Breakaway Plug and Cables Above Optiic Breakaway 0-0 Junction Box Assembly (Optic Breakaway), with -Pin Socket for Optic Breakaway Plug and Cables Above 0-0 Thermistor Plug Storage Hanger (Bolts to Rack Stucture) Plug Storage Hangers ACCESSORY ITEMS 0-0 Optic Plug Storage Hanger (Bolts to Rack Stucture) Rack Tester 8-8 Thermistor & Optic Rack Monitor Tester (Includes Ground Verifacction Test) Copyright 0, OPW Fluid Transfer Group Printed in USA /

BOTTOM-LOADING TRUCK RACK MONITORS (TYPICAL WESTERN USA & WESTERN CANADA) PHONE FAX: (8) -0 0 Mattox Road Kansas City, MO 0 www.civacon.com 80-0 80-0 90S-000 9S-000 9SR-9 BCU- RACK MONITOR PLUG & CABLE ASSEMBLIES INCLUDING (ALSO AVAILABLE SEPARATELY ON NEXT PAGE) USA & CANADA - West of Rockies USA & CANADA - West of Rockies Standard Plug & Cables With Plug & Cables 80-XXX 80-XXX Optic (-) Rack Monitor with Ground Verification, Red/Green Indicator Lights. Available in 0 (-0) or 0 (-0) Volt Optic (-) Rack Monitor with Ground Verification, Red/Green Indicator Lights. Available in 0 (-0) or 0 (-0) Volt. Including the 0-0 Junction Box and One BCU- Bypass Authorizer 90S-000 Blue, Locking Pin, Optic Plug with 0 0-Conductor Orange Coiled Cable and 00 Junction Box Assembly 9S-000 OPTION Overfill Bypass Authorizer BCU- 9SR-000 Blue, Locking Pin, Optic Plug with 0 0-Conductor Orange Coiled Cable and 0 Breakaway Junction Box Assembly Blue, Locking Pin, Optic Plug with 0' -Conductor Blue Coiled Cable (with Shielded #9 ) and 0 Breakaway Junction Box Assembly (Plug & Cable Construction Equivalent to Scully P/N 8) Electronic Overfill Bypass Authorizer for 80 Optic Rack Monitor (Requires 0-0 or 0-8x0 Junction Box) NOTE: Does Not Bypass Ground Verification Function of 80 - ONLY Overfill Detection Function Replcement Plug and Cable Assemblies and Accessories continued on next page Copyright 0, OPW Fluid Transfer Group Printed in USA /

BOTTOM-LOADING TRUCK RACK PLUG & CABLES (TYPICAL WESTERN USA & WESTERN CANADA) PHONE FAX: (8) -0 0 Mattox Road Kansas City, MO 0 www.civacon.com 00-00 0-0 0-0 0-8x0 00-00 0-0 00SR-00 0SR-0 0-0 8-8 PLUG AND CABLE Plain Cover, Non-Breakaway 00-00 Junction Box Assembly (Non-Breakaway), for use with any Non-Breakaway Optic Plug and Cables Below Optiic Breakaway 0-0 Junction Box Assembly (Optic Breakaway), with -Pin Socket for Optic Breakaway Plug and Cables Below With Bypass Port for BCU- Use (Order Plug & Cable Separately on Next Page) Standard Plug 0-0 0-8X0 Junction Box Assembly (Non-Breakaway) with BCU- Port, for use with any Non-Breakaway Optic Plug and Cables Below Junction Box Assembly (Optic Breakaway) with BCU- Port, with -Pin Socket for Optic Breakaway Plug and Cables Below 00-00 Optic Plug with 0' 0-Conductor Coiled Cable 0-0 Optic Plug with 0' 0-Conductor Coiled Cable and -Pin Breakaway Plug (for use with 0 J-Box) 00SR-00 Optic Plug with 0' -Conductor Blue Coiled Cable (with Shielded #9 - Replaces Scully P/N 8) 0SR-0 Optic Plug with 0' -Conductor Blue Coiled Cable (with Shielded #9 ) and -Pin Breakaway Plug (use with 0 J-Box) Plug Storage Hanger 0-0 Optic Plug Storage Hanger (Bolts to Rack Stucture) ACCESSORY ITEMS Rack Tester 8-8 Thermistor & Optic Rack Monitor Tester (Includes Ground Verifacction Test) Copyright 0, OPW Fluid Transfer Group Printed in USA /

GROUND VERIFICATION ONLY FOR TOP-LOADING RAILCAR OR TANK-TRUCK (OR OFF-LOADING) PHONE FAX: (8) -0 0 Mattox Road Kansas City, MO 0 www.civacon.com 800-0 90-90 90-COIL 00-00 90-90 90-COIL 0-0 0-COIL 0-0 0-COIL (Two Shown) KEY PRODUCT CONNECTION STYLE PRODUCT # DESCRIPTION GROUND VERIFICATION MONITOR 800-0 Ground Monitor, with Red/Green Status Lights Available in 0 or 0 Volt GROUND VERIFCATION CONNECTOR, CABLE & ASSEMBLIES REPLACEMENT CONNECTOR & CABLE ASSEMBLIES (Rail Car & Tanker Use) (For Tankers with Dual Balls) ACCESSORY ITEM APPLICATION NOTES: 90-90 Ground Verification Clamp with 0' straight cord and 00-00 Junction Box 90-COIL Ground Verification Clamp with 0' coiled cord and 00-00 Junction Box 90-90 Ground Verification Dual Ball Plug with 0' straight cord and 00-00 Junction Box 90-COIL Ground Verification Dual Ball Plug with 0' coiled cord and 00-00 Junction Box 0-0 Ground Verification Clamp with 0' straight cord 0-COIL Ground Verification Clamp with 0' coiled cord 0-0 Ground Verification Dual Ball with 0' straight cord 0-COIL Ground Verification Dual Ball Plug with 0' coiled cord Brass Ground Stud with Nut and Lockwasher. (Two Needed per Tanker - for Use with Dual Ball Connector). The Isolated Jaw Clamp Connection is typically used on rail cars and on tankers where no permanent ground connection point is provided.. The Dual Ball Connector can only used on tankers which are already equipped with dual brass ground studs per TTMA Recommended Practice RP with Balls spaced -/ (.mm) apart. Copyright 0, OPW Fluid Transfer Group Printed in USA / 8