LK Shunt Cabinet VS2, Shunt Cabinet VS2 Prefab

Similar documents
LK Manifold Shunt VS2

LK Manifold RF. Design. Requirements

LK Manifold Shunt VS 2-2,5

C15C C15C. Page 1 of 20

Installation Instructions Table of Contents

LK Manifold RF. Design. Requirements. Documentation

Subaru Front Mount Intercooler Kit STI Subaru Front Mount Intercooler Kit STI

METTEC DESK CASES DESK CASES

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

LPE C5 Battery Relocation Kit

Duct System for Danfoss Air Units

INSTRUCTION MANUAL SVEA-ALLROUND GRAIN AUGER 152 mm

CENTRAL VACUUM SYSTEMS

Maintenance instruction

Blanking plate: To incorporate spare positions. 1. With M6 screws for installation from the connection blocks.

920 Remote Control Switches

BESTEEL 170 SERIES CURTAIN TRACKS

LiteDOT Installation Document

BLACKBIRD INSTALLATION SUPPLEMENT

Ropox Shower & Changing Bed

ITEM QTY CHECK PART NUMBER DESCRIPTION. NOTE: This package does not include any accessories for gauge installation

ITEM QTY CHECK PART NUMBER DESCRIPTION

10. Installation Instruction

Security Is So Square

Raw Designs Scorpion Tips Install

CBC-A Air curtain cabinet

Hinges and Flap Fittings Application Matrix

Flue installation instructions. Air flue duct for use with ecomax and ecotec boilers. For the installer

Installing Your 220v J-POD Kit

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Cable-Tight Wire Management System

ARQUA STATION DF4 + DF7

DUETTE POWERRISE SHADES

Document: 3 inch Vane Pump System-in-a-Box Assembly Instructions SPS100370

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL

OVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM INSTALLATION INSTRUCTIONS

UTV Universal Stronghold Auto- Latch Double Boot Mount

SolarSheat Wall Installation Manual

MANIFOLDS & WATER TEMPERATURE CONTROL

INSTALLATION INSTRUCTIONS BULL BAR DODGE RAM 1500 PART # B-D1091;B-D2091

INSTALLATION INSTRUCTIONS FRONT RUNNER GRILLE GUARD 2015 TRANSIT VAN (FULL SIZE)

ABOVE-GROUND AUTOMATIC POOL COVERS

Glass & Wooden Door Fittings

SERIES II WALVIT + CUBE. 1.28/0.8 Gal (4.8/3 Litre)

MAKING MODERN LIVING POSSIBLE. Danfoss Air. Installation manual for Danfoss Air Flex duct systems DANFOSS HEATING SOLUTIONS

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

1464. Interior Installation. Cover Rear Seat Support Cut the vinyl to approximately the size of the rear seat support.

THE ENCLOSURE HARDWARE SUPPLIER

INSTALLATION INSTRUCTIONS FORD F-150 2WD & 4WD RETAINS FACTORY TOW HOOKS PART #P3063

ROWEKO LOAD-SECURING EQUIPMENT

House Hydrant Installation Instructions

file://c:\program Files\tsocache\OFFICE_5416\SY1~us~en~file=SY131B46.htm~gen~ref...

Gun Port Patterns (Part 1 of 2)

Bridge Overhang Brackets

The M7 Direct Flow Intercooler (DFIC) Installation Guide

Installation instruction do88 performance Intercooler for Volvo S60/V60 T6 MY10-

M-5230-V6 Mustang V6 Dual Exhaust Kit INSTRUCTION SHEET

Lifting height 5.5" - 72" with adapters " Height overall 165" Width between columns 122" Drive through 109" Width overall 151.

Contractors Guide Central Inverter System Installation

Sport Model with an easy-lube spindle

deutsch Taifun GT II Bedienungsanleitung User Manual english

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

IMPORTANT WARRANTY & INSTALLATION INSTRUCTIONS ATTACHED

Flexible ducting system FlexPipe plus Round 75 mm Ø in combination with Oval 51 x 114 mm

piece of straight pipe with a minimum length of 25 cm. (see figure 13) For this purpose the 45 long bend is included in the Wavin AS program.

Auto-Lift Operating System

55-64 Full Size Chevy Installation Instructions Standard Disc Conversion

Installation Instructions

SYSTEM KAN-therm. Underfloor heating. Comfort and efficiency TECHNOLOGY OF SUCCESS ISO 9001

PARTS LIST: 8581 DODGE LONG ARM BRACKETS 03-13

GT Mustang Shaker

A Assembly Instructions Trampoline Piccolo Art with Special Installation Frame

9-I DUETTE SHADES POWERVIEW MOTORISATION

Installation Guide Current Ford F-250 & Ford F-350 Super Duty. Product Code: 109 & 119

SolarSheat Wall Installation Manual

ABS Dry Installed Waste Water Pumps Series FR

HP-2 / HP-6 Direct Installation Instructions Overview

Personal Protection Equipment (PPE) Safety Glasses Protect eyes Welding Mask Protect eyes and face

Tools Required. Metric Wrench Set Screwdriver Set Metric Socket Set Pliers Heavy duty hydraulic Jack and Car Stands Box knife or similar Hacksaw WD40

All cores due 30 days after invoice date - no credit after 60 days.

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

ATTENTION. 1. Do not attempt to use the power unit to extend your cylinder. This must be done manually.

ROUSSILLON MODEL Motor inside shaft 250 Nm

US FUTABA ESTABLISHED 1983 NEW IN THIS SECTION OFFICE LINE. Short Type 4 5-1/8" ( mm) 23.5 Ø /4" 45 mm. 1-3/16" 30 mm 5/8" 15.

12 6mm x 22mm OD x 2mm Flat Washers mm x 40mm Button Head Bolt Plates 12 6mm Hex Nuts 6 12mm Plastic Retainers

Maintenance Instructions

1501 Industrial Way N., Toms River, NJ Fax: PACKING LIST

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PIPE WORK. This work covers part of outcome 2 of the Edexcel standard module:

1501 Industrial Way N., Toms River, NJ Fax: PACKING LIST INSTALLATION INSTRUCTIONS

SS732HF NISSAN D40 NAVARA / R51 PATHFINDER 4.0Ltr V6 Petrol (VQ40 Engine) Built: Nissan Motor Iberica, S.A.

11 - Fairings. Fairings. February XLF Page 11-1

deutsch Taifun GSL Bedienungsanleitung User Manual english

Recommended Tools: 3/8 drive ratchet 3/8 drive 13mm socket 3/8 drive 15mm deep socket 10 3/8 ratchet extension Grommet pullers

2 of 10. Bronco Parts. Dana 44 Yukon Hardcore Chrome Moly Axle Set $ Dana 44 Chrome Moly 4340 Axle Set With $325.00

GENERAL INSTALLATION MANUAL

Construction/Installation Manual Glareshield & Cabinet

BLACKBIRD INSTALLATION SUPPLEMENT

Installation Instructions

ACCESSORIES FOR SZE2 CABINETS

Transcription:

LK Shunt Cabinet VS2, Shunt Cabinet VS2 Prefab Design LK Shunt Cabinet VS2 The LK Shunt Cabinet VS2 is designed to be used when you wish to hide the LK Manifold RF and LK Manifold Shunt VS2. The cabinet has a sealed base with rubber pipe grommets. The base of the cabinet is fitted with a drainage opening which allows any water leakage to drain to a location that can be inspected in accordance with industry practices. The cabinet is made from 1 mm powder coated steel plate, RAL 9016. The cabinet can either be built into a wall or externally on a wall. The minimum stud-frame thickness when builtin is 95 mm. The cabinet is intended for right mounting, i.e. the primary shunt connection is from the right side via the cabinet base. The cabinet should be supplemented with a frame/hatch. There are two types of frame/hatch depending on whether the cabinet is built into or installed externally on an inner wall. LK Shunt Cabinet VS2 For external mounting, the cabinet should also be supplemented with a base to hide the pipes between the cabinet and floor. The LK Shunt Cabinet VS2 is supplied with pipe grommets, a bellow sleeve for drainage, 1.5 metres conduit for drainage, a drainage elbow with outlet plate, cable grommets for room control, spray guard and installation instructions. The back of the cabinet has four prefitted M8 nuts, which can be attached to the LK Cabinet Stand if you wish to install the cabinet before a concrete base is cast. LK Shunt Cabinet VS2 Prefab The upper side of the cabinet includes knock-out holes if needed for cable grommets for room control. LK Shunt Cabinet VS2 Prefab The LK Shunt Cabinet VS2 Prefab has an identical design to the above but with a pre-installed LK Manifold Shunt VS2 and the LK Manifold RF. The manifold is fitted with the LK Connection Couplings for PE-X/PAL pipes dim. 16. 1 (11)

LK Frame/hatch GV The LK Frame/hatch GV is intended for use with the LK Shunt Cabinet VS2. On delivery, the hatch is fitted with a screwdriver latch and a key latch is available as an accessory. The LK Shunt Cabinet VS2 should be supplemented with a frame/hatch. There are two types of frame/hatch. When the cabinet is built into a wall, the LK Frame/hatch UFH INB is used which has a precipitating frame in order to cover the hole around the cabinet. The frame covers an area of 15 mm beyond the edge of the cabinet. When the cabinet is installed externally on a wall, the LK Frame/hatch UFH UTV is used, which fits edge to edge with the outsides of the cabinet. Assembly requirements Assembly in stud-frame For installation in a wall, a minimum stud-frame thickness of 95 mm is required. In cases where the cabinet is in a wet room, the cabinet must not be placed with its opening in wet zone 1. See image below from the Swedish industry rules on Säker vatteninstallation for a definition of wet zone 1. 1,0 m våtzon 1 1,0 m Wet zone 1 Installation height when installing in a stud-frame In order to assemble and leave space for the drainage pipe then the cabinet must be mounted at least 250 mm between the bottom of the cabinet base and the installed floor. The drainage pipe should be installed with a slope. LK Frame/hatch INB LK Base The LK Base is used when the Shunt Cabinet VS2 is installed externally on a wall. The LK Base hides the pipe installation between the cabinet and floor. The base can slide for heights from 220 to 280 mm. The base includes holes for installing cabinet drainage. If an alternative placement is used for cabinet drainage, the supplied cover plug can be used to hide the hole in the base. Installation height when installing ext. on a wall When installing externally on an inner wall the cabinet should be placed 250 (± 20) mm above the completed floor in order to provide space for the base. Assembly in stud-frame LK Base Assembly near a wall When installing near a wall in a stud-frame, at least 35 mm is required from the outside of the cabinet to adjoining walls to provide space for the LK Frame/hatch INB. 2 (11)

Supplied with product 1 2 17 3 16 4 15 14 13 12 5 6 7 8 11 10 9 No. Name Quantity Article no 1 Shunt Cabinet 1 pcs - 2 Bracket, manifold 2 pcs incl. in package 33950 3 Bellow Sleeve 25 1 pcs 33402 (also incl. in package 188 21 43) 4 Conduit Ø25 1.5 m 187 06 65 5 Seal for Drainage Elbow 1 pcs incl. in package 188 21 43 6 Assembly screws for Drainage Elbow (4.2 x 65 mm) 2 pcs incl. in package 188 21 43 7 Drainage Elbow 1 pcs incl. in package 188 21 43 8 Outlet Plate White 1 pcs 188 21 44 (also incl. in package 188 21 43) 9 Cable Grommet 10 pcs 33952 (also incl. in package 33950) 11 Pipe Grommet 8-20 16 pcs (800) 26 pcs (1050) 33401 12 Pipe Grommet supply pipe 12-34 2 pcs 187 44 84 13 Washer M5 4 pcs - 14 Bolt M5 4 pcs - 15 Washer M6 4 pcs incl. in package 33953 16 Butterfly nut M6 4 pcs incl. in package 33953 17 Wood screws (5 x 35 mm) 4 pcs incl. in package 33953 18 Seal for wood screws 4 pcs incl. in package 33953 - Spray Guard (705 x 397 mm) 2 pcs (800) 3 pcs (1050) - Spray Guard (705 x 197 mm) 1 pcs (800) 0 pcs (1050) 33951-3 (11)

Working procedure 1 - Prepare pipe grommets Prepare pipe grommets for feed pipes and underfloor heating pipes by adapting/cutting grommets to the correct dimension based on the pipe dimension use If the seal for the pipe dimension is damaged when cutting, then it must be replaced with a new seal. Sealing Cutting pipe grommet. 1 Sealing A cross-section of the pipe grommet shows the placement of the pipe seal. 2 3 4 Cutting pipe grommet. Cutting level Dim. Pipe Dim. Conduit (PiP) 1 Ø12 2 Ø16-20 3 Ø25 Ø25 4 Ø32 Ø34 A cross-section of the pipe grommet shows the placement of the pipe seal. 4 (11)

2 - Knock-out Remove the required number of knock-out holes for cables to room control. Install the cable grommets. If the feed pipes are to be connected from the side, the knock-out holes are removed from the side of the cabinet. The pipe grommets are then installed for the feed pipes. 4 - Install the cabinet Install the cabinet in the stud-frame externally on an existing wall taking into account the headings above regarding assembly height, wet zone 1 and installation near a wall. Fix the manifold cabinet in the building structure. For wood stud constructions, use the screws and sealing plates supplied. The cabinet can also be fixed using the LK Leg Stand. Pay attention to the depth of the cabinet's placement so there is also space for any pipe insulation. The cabinet should never be installed further out than edge to edge with the stud-frame, so the Frame/hatch GV INB can be installed. If the cabinet is placed on an outer wall, it should be installed on the warm side of the construction, inside the airtight foil. Remove the knock-out holes using a hammer and screwdriver 3 - Assemble the pipe grommets and sealing plugs Fit the adapted pipe grommets and the LK Sealing Plug before the cabinet is installed in its final location. Pay particular attention during the assembly of pipe grommets and sealing plugs so the cabinet base is sealed. LK Sealing Plugs are fitted so the LK Logo can be seen inside the cabinet. Securing the cabinet in a stud-frame 5 - Assemble the manifold & manifold shunt Assemble the bracket attachments on the cabinet's rail. Refer to picture below, Assembling the LK Manifold RF. LK Manifold RF is then mounted on the bracket attachments (when installing the LK Shunt Cabinet VS2 Prefab, the manifold is already mounted). Follow then the included instructions for installation of the manifold and pressure and tightness testing of its pipe connections. Install the shunt bracket at the assigned place in the cabinet. Then install the shunt group in the bracket. Push the manifold to the shunt group and tighten the unit. Assemble the pipe grommets and sealing plugs 5 (11)

Assembling the LK Manifold RF Leak testing of the cabinet base 8 - Install cabinet drainage Note that any leakage should be easy to quickly discover, which you should take into account when deciding where to have the outlet. Two different types of drainage elbows can be used, see below. Assembling the LK Manifold Shunt VS2 6 - Pipe grommets Pull the underfloor heating pipes through the pipe grommets. This is easier if the pipes have been lubricated with soapy water or similar. The pipes are then connected to the manifold in accordance with the instructions for the manifold. 7 - Leak testing of the cabinet base Connect the conduit with the bellow sleeve to the cabinet's drainage opening. Bind the conduit so its opening is slightly above the base of the cabinet, or alternatively, use the LK Bottom Plug in a drainage elbow or manifold cabinet. Pour water up to the edge of the cabinet base and wait about 10 minutes. Then check that the cabinet base is sealed. Look at the underside of the cabinet base to be sure there is no trace of water. When the cabinet seal has been checked, the cabinet drainage is assembled as below. A leak test is always carried out on the cabinet base before the wall covering is mounted. Drainage elbow directly joined to the cabinet's outlet drainage The drainage is from the wall surface under the cabinet. Ensure that the white rubber seal is correctly mounted in the drainage elbow. Connect the drainage elbow directly to the cabinet's outlet drainage. For cabinets mounted externally on the wall, the drainage elbow runs through the pre-drilled hole in the base. The drainage elbow connected via a conduit. Connect the conduit with the bellow sleeve to the cabinet's drainage opening. Ensure that the white rubber seal is correctly mounted in the drainage elbow. Then connect the drainage elbow to the conduit. Note that the pipe should rest in the drainage elbow, about 40 mm deep. Fix the drainage elbow in a suitable location against the wall or floor beam. Use the two screws supplied in securing holes of your choice. Max. length for the conduit should not exceed 1.5 m and should have at most one 90º elbow. Ensure that the conduit is installed with a slope towards the outlet and the conduit is fixed. 6 (11)

Install the LK Outlet Plate in the outlet pipe. If necessary, the inside of the outlet pipe can be lubricated with soapy water or something similar. A more exclusive finish is available as an accessory with the LK Outlet Plate Chrome (Article no. 188 09 99). Drainage elbow directly joined to the cabinet's outlet drainage Assembly of the LK Outlet Plate 10 - Install Spray Guard Assemble the spray guard supplied. Be careful that the guard is pushed out to the side so the entire cabinet width is covered by the guard. The drainage elbow connected via a conduit 9 - Install outlet plate Install the wall board with holes for the drainage elbow's outlet pipe. Hole diameter approx. 26 mm. Connect any sealing layer in accordance with instructions from the supplier. The LK Pipe Membrane can be obtained from LK Systems (Article no. 481 43 82), but the sealing contractor should carry out the assembly and be responsible for the adhesiveness of the seal in line with the Swedish industry regulations from Byggkeramikrådet (BBV), GVK (Säkra Våtrum) and Måleribranschens våtrumskontroll (MVK). Upon completing installation of the wall covering, cut the length of the drainage elbow using the LK Pipe Mill DB, or cut the pipe to a suitable length using a hacksaw blade or knife. Ensure that the surface is not damaged, leave 1-2 mm of the outlet pipe outside the wall surface. 11 - Install Frame/hatch There are two types of frame/hatch depending on whether the cabinet is built into or installed externally on an inner wall. On delivery the hatch is fitted with a screwdriver latch, though an LK key latch is also available as an accessory (LK-no 327 85). 11a - Install Frame/hatch UFH INB When the cabinet is built into a wall, the LK Frame/hatch UFH INB is used which has a precipitating frame in order to cover the hole around the cabinet. The frame covers an area of 15 mm beyond the edge of the cabinet. Install the LK Frame/hatch using the M5 screws provided. If the cabinet is installed so far into the construction that the screws are too short, then these should be replaced with longer screws (not included). 11b - Install Frame/hatch UFH UTV When the cabinet is installed externally on a wall, the LK Frame/hatch UFH UTV is used, which fits edge to edge with the outsides of the cabinet. 7 (11)

Installation of LK Shunt Cabinet VS2 Prefab The cabinet is installed in accordance with the instructions above with the exception of the installation of the LK Manifold RF and the LK Manifold Shunt VS2, which are already assembled on delivery. Plate and screws for the LK Frame/hatch UFH UTV Install the frame using the screws and mounting plate provided, see picture above. Fit the four white cover plugs on the end of the cabinet. Assembly aids Assembly is easier with the LK Cabinet Stand The back of the cabinet is fitted with four anchor points (M8 nuts) which can be used to assemble the cabinet before the concrete base is cast. The LK Cabinet Stand can be used as an aid and is assembled as below. 12 - Install Base With an external installation of the LK Shunt Cabinet VS2, install the LK Base by first pushing the upper part of the base into the intended grooves in the cabinet frame. Also ensure that the drainage elbow runs through the intended hole. The lower part of the base is then pulled out to the floor. When the correct height is reached, then the installation is fixed using screws on the front of the base. Adapt the length of the drainage elbow to the outside of the base and install the outlet plate. LK Cabinet Stand with anchor clips. LK Base installation Outlet plate fitted on base Mount the four M8 nuts provided in the back of the cabinet. Attach pipe fixings to the extended bolts. Slip on the round bar and attach the conduit pieces provided with the stand. The conduits stop the stand from becoming set in the concrete, making it reusable. Knock down the round bars through the insulation and into the sand until the installation feels stable. Lift up the cabinet to a suitable height and tighten the fixings. Tape the conduits to the legs of the stand to stop the conduits from moving when pouring the concrete. 8 (11)

Mounted cabinet stand. LK Leg Stand Close-up of fastening to cabinet. Assembly is easier with the LK Leg Stand The LK Leg Stand simplifies cabinet assembly on prefabricated concrete joists. Manufactured from galvanised steel plate. Supplied in pairs with 4 self-tapping screws to fix to the manifold cabinet. The feet have 6 mm holes for fixing to the concrete floor structure. The legs are secured using a bolt or metal nail plug (not supplied). In cases where the manifold cabinet is not adequately secured by the leg stand, then the cabinet should also be secured to the wall 9 (11)

77 47,5 735 710 214 257 100 520 90 25 39 700 740 Assembly instructions LK Shunt Cabinet VS2, Shunt Cabinet VS2 Prefab Dimension drawings LK Frame/hatch UFH, UTV 30 14 B1 LK Frame/hatch UFH, INB 65 14 B2 8 44 2 LK Shunt Cabinet VS2 Ø 40 x Hål 50 100 88 174 95 50 337 B1 24 36 15 B4 15 Ø 40x2 Knockouts 24 25 30 Ø 20x10 Knockouts LK Base 96 26 B3 Ø 28 Cabinet type B1 mm B2 mm B3 mm No. of holes B4 mm 800 800 840 803 14 + 2 770 1050 1050 1090 1053 24 + 2 1020 10 (11)

Pipe dimensions The table shows which dimensions and pipe types that can be connected to the LK Shunt Cabinet VS2/ LK Shunt Cabinet VS2 Prefab. Pipe grommet PE pipes Metal pipes Pipe-in-Pipe conduit dimension Pipe Grommet 8-20 8, 12, 16 & 20 mm - - Pipe Grommet 20-34 for supply pipes in PE 20, 25 & 32 mm 22 & 28 mm 34 mm LK Pipe Grommet 8, Quattro* 8 mm - - LK Pipe Grommet 32, Pipe-in-Pipe* 32 mm - 40-44 mm * ordered separately. Article data Name Article no Comment LK Shunt Cabinet VS2 800 243 53 61 For LK Manifold Shunt VS2 and VKF-RF 2-7 LK Shunt Cabinet VS2 1050 243 53 62 For LK Manifold Shunt VS2 and VKF-RF 2-12 LK Shunt Cabinet VS2 800 Prefab -2 243 53 79 With installed LK Manifold Shunt VS2 and VKF-RF 2 LK Shunt Cabinet VS2 800 Prefab -3 243 53 80 With installed LK Manifold Shunt VS2 and VKF-RF 3 LK Shunt Cabinet VS2 800 Prefab -4 243 53 81 With installed LK Manifold Shunt VS2 and VKF-RF 4 LK Shunt Cabinet VS2 800 Prefab -5 243 53 82 With installed LK Manifold Shunt VS2 and VKF-RF 5 LK Shunt Cabinet VS2 800 Prefab -6 243 53 83 With installed LK Manifold Shunt VS2 and VKF-RF 6 LK Shunt Cabinet VS2 800 Prefab -7 243 53 84 With installed LK Manifold Shunt VS2 and VKF-RF 7 LK Shunt Cabinet VS2 1050 Prefab -8 243 53 85 With installed LK Manifold Shunt VS2 and VKF-RF 8 LK Shunt Cabinet VS2 1050 Prefab -9 243 53 86 With installed LK Manifold Shunt VS2 and VKF-RF 9 LK Shunt Cabinet VS2 1050 Prefab -10 243 53 87 With installed LK Manifold Shunt VS2 and VKF-RF 10 LK Shunt Cabinet VS2 1050 Prefab -11 243 53 88 With installed LK Manifold Shunt VS2 and VKF-RF 11 LK Shunt Cabinet VS2 1050 Prefab -12 243 53 89 With installed LK Manifold Shunt VS2 and VKF-RF 12 LK Frame/hatch GV 800 INB 243 46 79 Intended for GV 800 cabinets built into the wall LK Frame/hatch GV 1050 INB 243 53 63 Intended for GV 1050 cabinets built into the wall LK Frame/hatch GV 800 UTV 243 46 78 Intended for GV 800 cabinets installed externally on the wall LK Frame/hatch GV 1050 UTV 243 53 64 Intended for GV 1050 cabinets installed externally on the wall LK Base 800 (depth 95) 243 46 88 Accessories for external installation LK Base 1050 (depth 95) 243 53 65 Accessories for external installation LK Lock with key 327 85 Accessories LK Pipe Grommet 8-20 334 01 Spare part LK Pipe Grommet 20-34 187 44 84 Spare part LK Sealing Plug 40 339 32 Spare part LK Bottom Plug 188 84 88 Accessories LK Pipe Grommet 32 Pipe-in-Pipe with 40 mm conduit 241 95 95 Accessory (sold in pairs) LK Pipe Grommet 8 mm, Quattro 241 94 61 Accessories LK Outlet Plate chrome 188 09 99 Accessories LK Sealing Membrane 481 43 82 Accessories LK Pipe Mill DB 243 46 08 Accessories LK Cabinet Stand 241 88 94 Accessories LK Plastic Clips conduit 25 188 07 62 Spare part LK Leg Stand 187 82 02 Accessories LK Systems AB, Box 66, 161 26 Bromma, Sweden www.lksystems.se/en 11 (11)