LK Manifold Shunt VS 2-2,5

Similar documents
LK Manifold Shunt VS2

underfloor heating PRODUCTS FOR UNDERFLOOR HEATING

Products for underfloor heating

LK Manifold RF. Design. Requirements

LK Manifold RF. Design. Requirements. Documentation

LK 820 ThermoVar. Technical Data. Thermic Valves and Check Valves. Opening temperatures 45 C, 55 C, 61 C, 66 C, 72 C or 80 C.

LK Shunt Cabinet VS2, Shunt Cabinet VS2 Prefab

PRODUCTS FOR HEATING AND TAP WATER SYSTEMS. Product Catalogue

AV 23 Balancing valves SETTER Inline

LK Control v.3 & LK Control v.3 - RA

DISTRIBUTION GROUP WITH THERMOSTATIC REGULATION. Upper connections G1 F Without fittings Fittings with running connection* Without pump

Premounted Midi Shunts

COMPONENTS FOR SOLAR THERMAL SYSTEMS

FCU Floor Control Unit

Electrically operated valves Series KM-09, 5/2- and 5/3-way G1/8 680 to 950 Nl/min (0.691 to Cv)

Floor heating manifold with automatic flow control

Pump Stations for Heating Circuits

MANIFOLDS & WATER TEMPERATURE CONTROL

MrPEX 1 ¼ Stainless Steel Manifold Installation Guide

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB

Controls and valves for heating systems

Pressure independent combined control and balancing valves with independent EQM characteristics

Premounted Midi Shunts

2-Way & 3-Way Non Spring Return Characterized Ball Valves

PRO-BALANCE 1 1/4 IN. BRASS MANIFOLD. Product Instructions

4-Way Mixing Panel Submittal - Page 1 of 6

Thermostatic radiator valves with presetting

T2 Wall Hung Radiator & UFH Manifolds

CALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.

Delta HE 35-XX, 55-XX

AIR COOLED CHILLERS WATER COOLED CHILLERS

COMPONENTS FOR SOLAR THERMAL SYSTEMS

KS Pump Stations. Engineering Submittal Sheet. Installation Sets for Collectors

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components

Components for central heating

THE NEW GENERATION MIXING VALVES. NEWS LK 840 ThermoMix 2.0 LK 841 ThermoMix 2.0

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

ZTV/ZTR. Externally threaded 2- and 3-way zone valves. Function. No leakage in closed position

PRESSURE CONTROL VALVES SABS 198

dynacon floor heating manifold with automatic flow control

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

USER GUIDE 12 V Lead acid batteries Ah

TA-FUS1ON-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

EV RANGE MULTI-SPEED GLANDLESS CIRCULATORS

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

CPLab / CP Factory. Application module magazine. Data sheets

Manifolds series 73A and 77A. Instruction manual

Maximum output power with circulator Wo 6 kw. Maximum output power without circulator Wo 5 kw

Art.918C Pre-assembled manifold with flow meters, air

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

RADIATOR VALVES / RADIATOR VALVES WITH PRESETTING

Thermal flow sensor TFS-35

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

Data sheet: Wilo-Yonos PICO 25/

Series description: Wilo-Stratos ECO-STG

lindab comfort Regula Control er

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

2- and 3-port valves with flanged connections, PN 16

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

CALEFFI. HydroMixer motorized temperature mixing unit. 167 series 01239/13 NA. Function

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

Data sheet: Wilo-Stratos PICO 25/1-6

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

ZONE CONTROLE / 2-WAY

Fan-coil valves Series

Data sheet: Wilo-Stratos PICO 25/

HERZ-Motorised flow controler

Manifold Isolation Valves

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

CALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB

HKV 1 1/4 in. Brass Manifold Product instructions. Construction Automotive Industry

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

ΑΥΤΟΜΑΤΗ ΣΤΡΑΤΣΩΝΑ ΕΛΕΓΚΤΕΣ

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Data sheet: Wilo-TOP-S 40/10 (1~230 V, PN 6/10)

ARM1000/2000. Standard Specifications

Powers Controls Powermite Two-Way Flared Valves Normally Open/Normally Closed

CALEFFI. Manifolds in composite specifically designed for radiant panel systems. 670 series 01126/05 GB. Function

Grundfos Home Booster

Composite PEX-AL-PEX Tubing

Operating Instructions for Paddle Bellows Flow Monitor. Model: FPS-P...

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

Installation and Operation Instructions K38 HeatBloC - DN 32

CALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function

2- and 3-port valves with flanged connections, PN 16

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Data sheet: Wilo-TOP-S 40/4 (1~230 V, PN 6/10)

VZ*19* VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C

Series P255MM/ML Single/Dual Pressure Input Condenser Fan Speed Controllers For Three Phase Motors (incl. built-in RFI suppression filter)

Produkt informatie COSTER T.E.

Product and installation manual. Underfloor Heating Composite Manifold

Han K 3/0, K 3/2 / Han HC Modular. Contents Technical characteristics Han K 3/0, Han K 3/ Inserts Han K 3/0, Han K 3/

Transcription:

LK Manifold Shunt VS 2-2,5 Design LK Manifold Shunt VS (Variable Speed) is a water temperature control pack complete with two way control valve used in systems with a primary pump. The shunt unit is mountable from both the left and right of LK Manifolds. The shunt unit is fitted as standard with manual controls for both flow (speed and temperature) and high limit temperature settings. 12 11 13 8 9 2 The shunt unit is preferably installed in systems with a weather compensated primary flow temperature; alternatively, LK Manifold Shunt VS may be supplemented with LK Control v.3, (see more under section LK Control v.3 below). Where other electronic control is required, LK can supply suitable valve actuators of 230V or 0-10V. The shunt unit, by use of the built-in max temperature thermostat, may also be used in systems with constant flow temperatures. The VS (Variable Speed) version is supplied complete with an automatic speed-controlled pump for reduced energy consumption and more quiet operation. Guideline capacity of this shunt unit is 200 m 2 floor surface. The capacity is dependent on the primary temperature, pressure, floor heating installing system, etc. 1. Supply flow from primary circuit ¾ BSP female. 2. Supply flow to manifold 1 BSP male. 3. Return flow connection to primary circuit ¾ BSP female. 4. Return flow from the manifold 1 BSP male. 5. 2-port Control valve, Kvs 2.5 The control valve is manually adjusted for flow temperature, or may be replaced by motorized valve actuators (see LK Control v.3). 9 5 1 6 10 7. Isolation & flow control valve - primary return Valve for adjustment and control of the primary flow, also used as isolation valve. 8 mm hexagonal socket. 8. VF valve The valve is used in systems where the primary side pump cannot provide adequate drive pressure; progressive closing (choking) the valve enables the shunt s pump to draw water from the primary side. 8mm hexagonal socket. 9. Thermometers Built in thermometers to flow and return lines. 10. Built-in check valve 11. Temperature controller Factory-set to 50 C. Adjustable between 30-65 C (see table below). 12. Circulation pump Circulation pump, Grundfos Alpha 2L 15-60 with automatic speed control. 13. Wall fixing plate 3 4 7 6. Isolation valve - primary supply 8mm hexagonal socket. 1 (6)

Recommendations The manual control version of LK Manifold Shunt VS is best used in systems with external temperature (weather) compensation. Check the settings of the temperature limit control. Otherwise, it is advisable to fit the shunt unit with LK Control v.3 to ensure optimum operational comfort and low energy consumption. Assembly in LK Manifold Cabinet The shunt unit can be assembled to LK Manifold in specially designed wall mounted or built in cabinets. LK Shunt Cabinet UFH LK Shunt Cabinet UFH fulfils Sweden s plumbing safety regulations. The heating system should be fully flushed and cleaned before assembly and must be free of any contamination or particles, which may damage LK Manifold Shunt VS. Max 50% glycol mix. At assembly, ensure that the pump axle is in the horizontal plane. Valve actuators must not be located below the control valve. Carefully consider positioning of the shunt unit to minimize structural transmitted sound. Assembly LK Shunt Cabinet UFH 800 holds LK Manifold Shunt VS and LK Manifold RF 2-5 LK Shunt Cabinet UFH 1150 holds LK Manifold Shunt VS and LK Manifold RF 2-12 The shunt unit can be mounted directly to LK Manifolds from both the right and left. To facilitate this, two Manifold Supply Pipes of different lengths are supplied. The longer pipe is used for right mounting to LK Manifold (see illustration above). When fitting from the left, reposition the thermometer through 180º and rotate the pump. By-pass LK Manifold Shunt VS (Variable Speed) is supplied, as standard, with an automatic speed controlled pump; thus the manifold does not require a mechanical By-Pass. Note! At installation of LK Shunt Cabinet UFH in a wall, a minimum stud-frame thickness of 120 mm with 13 mm wall covering is required. The shunt unit is placed on the right hand side of the manifold, see instruction LK Shunt Cabinet UFH. The LK Shunt Cabinet UFH can be mounted on an existing wall by using LK Base UFH. LK Manifold Cabinet INB/UTV The following cabinet does not fulfill Sweden s plumbing safety regulations, and therefore normally is not sold on the Swedish market. LK Manifold Cabinet INB 800 holds LK Manifold Shunt VS and LK Manifold RF 2-5 LK Manifold Cabinet INB 1150 holds LK Ma nifold Shunt VS and LK Manifold RF 2-5 LK Manifold Cabinet UTV 1150 holds LK Manifold Shunt VS and LK Manifold RF 2-12 2 (6)

Note! When installing LK Manifold Cabinet INB, a minimum stud-frame thickness of 120 mm with 13 mm wall covering is required. Circulation pump LK Manifold Shunt VS circulation pump is supplied with automatic speed control. This ensures reduced energy consumption and efficient operation as the pump adjusts the flow to the requirement of the system. A cast arrow on the pump housing shows the direction of flow. For floor heating, it is advisable to set the pump on constant pressure regulation; please refer to the capacity chart below. Select the constant pressure curve which best matches the design system flow and pressure drop, choose curve Cp1 or Cp2. The electrical connection is easily set up with the accompanying plug-in. The plug-in replaces the 2-poled power switch. The plug has built-in cable strain relief for the supply cable. The circulation pump has built-in thermal motor protection. Ensure that the pump never runs dry and that the system is de-aerated before operation. Capacity chart P (kpa) 60 50 40 30 20 10 III Cp2 Cp1 II I POWER ON III II I Cp1 Cp2 0 0 5 10 15 20 25 30 Q (l/min) Setting for the temperature controller The temperature controller can be set between 30-65 C. The factory setting is set at 50 C. Always check the setting at the time of installation; please refer to the table below. Setting Temperature Min 30 C 1 36 C 2 38 C 3 42 C 4 46 C 5 50 C Max 65 C Systems with constant flow temperature The shunt unit can be used in systems where constant flow temperature is needed. Close the control valve. Set the temperature controller at the projected flow temperature e.g. 45 ºC (but see LK design data). Subsequently, open the control valve until (example) 45 C is read off the flowside thermometer. Variable flow valve Return line primary circuit The primary flow can be adjusted by adjusting the flow control valve in line with the table below. Revol Kv(m 3 /h) 2 0,4 3 0,7 4 1,2 5 1,7 6 2,2 7 2,7 8 3,2 9 3,7 10 4,1 11 4,5 12 5,0 Kvs 3 (6)

LK Control v.3 (accessory) LK Control v.3 LK Control v.3 is a complete unit for outdoor temperature (weather) compensated heat regulation, adapted and pre-programmed for LK s floor heating systems. LK Control v.3 consists of a control unit, valve actuator as well as a flow and outdoor temperature sensor. As an option, LK Control v.3 can be supplemented with LK Room Unit v.3 for regulating room temperature to the control unit s heat curve. This function is similar to a room thermostat, but with the possibility of remote control of the control unit. LK Room Unit v.3 is often used in areas with an open floor plan where only one room sensor is needed. When mounting LK Control v.3 the shunt group's hand actuator must be removed and replaced with the valve actuator, which is enclosed with LK Control v.3. See pictures below for placement. Troubleshooting The floor heating circuit is not heating up or not heating sufficiently Check that primary isolation valves are open. Check settings on the control valve. Check the manifold actuator and adjustment valves are open. Check the temperature controller setting. Check that the correct pump curve is selected. If the above checks have been completed and the heat to the manifold is still insufficient, this may point to too little drive (operating) pressure from the primary side main circulation pump (normally at the boiler). Check the main circulation pump operation and, whether pump speed can be increased. If that does not help, the shunt unit s circulation pump can help draw water from the primary side to the manifold by progressively closing the VF valve until the required temperature is reached. Remove the hand actuator with polygrip pliers towards the knurled brass ring. Replace with the valve actuator. 4 (6)

Technical data Article no. 241 85 12 Maximum operating pressure 0,6 Mpa Operating temperature secondary Max 65 C Operating temperature primary Max 80 C Ambient temperature Max 40 C Control valve Kvs 2,5 Isolation & flow control valve Kvs 5,0 Material Nickel-plated brass MS58, stainless acid-proof steel Maximum glycol mixture 50 % Circulation pump Grundfos Alpha 2L 15-60, with cast iron pump housing Voltage 1 phase 230V AC, -10 % / +6 %, 50 Hz, PE Load Max 45 W Current Max 0,38 A Encapsulation class IP42 Insulation class F Relative humidity Max 95 % Flow diagram Outdoor sensor Control unit Supply line sensor Control unit for remote control Secondary side under floor heating system T Primary side with main pump 5 (6)

Dimensions 393 309 213 93 188 60 124 66 36 24 105 25 255 339 213 93 24 36 66 124 60 188 105 25 6 (6) LK Systems AB, Box 66, 161 26 Bromma, Sweden www.lksystems.se