Remote engine start. Function

Similar documents
Remote engine start. Function. Behaviour. The remote engine start function is used to start the engine from outside the cab.

Split shaft power take-off activation. General information

Remote activation of visibility and lighting functions

Activation of EG power take-off. Function

Activation of a split shaft power take-off. Function

Foot plate activation according to EN Function

Speed limiter. General information on the functions. Order of priority between the speed limiters

Parameters Powertrain

Bodywork interface. Description. Bodywork interface. BCI (Bodywork Communication Interface)

Side marker lamps from the factory. General information

Split shaft power take-off activation via BWS. General information about the function. Operation with the vehicle in motion and stationary

Bodywork information in the instrument cluster

Release Notes. Scania Diagnos & Programmer 3 Version 2.28

Adjustable parameters Signalling and visibility systems

Tail lift preparation. General information about the preparation. Vehicles manufactured as from September 2015

Parameters Chassis. Introduction

List of notes Powertrain

Weighing equipment. Installation of weighing cells

Release notes for Scania Diagnos & Programmer 3, version 1.17

Connecting additional side marker lamps. Description. Activation

Operator's manual ATSc Instrumentation en-gb

C494 Connector for cable harness from cab to frame

16: Communication problems. Help when troubleshooting. Issue 1. Scania CV AB 2004, Sweden

Commander 15i Container and Pallet Loader. Property of American Airlines

Grounding and power supply. General information. Grounding in chassis frame. This document contains information on the following:

05/01/06 1er mai 2006 Cruise Control - Diagnostic Updates General Service Procedure Service Procedure Speed Control Diagnostic Tips Additional

Subject: Power Take Off (PTO) Models Affected: ADVISORY:

Trucks with a fixed flatbed body

ADD-ON REMOTE STARTER TO AFTERMARKET SYSTEM

Tail lamps Execution Note:

MaxxForce DT, 9, 10 ( )

Components for hydraulic equipment. General. Actions before starting a new hydraulic system

DASSAULT AVIATION Proprietary Data

ATA 49 AUXILIARY POWER UNIT

The parking brake is an electrically actuated system that operates drum brakes integrated into the rear brake discs. The

Bulk tankers. General information General information. Scania Truck Bodybuilder 22: Issue Scania CV AB 2017, Sweden 1 (11)

2002 F-150 Workshop Manual

MaxxForce DT, 9, 10 ( )

INSTALLATION GUIDE Table of Contents

General information on fuel consumption. Air resistance. This document summarises and explains the factors that affect a vehicle s fuel consumption.

For the most current information, visit the Roadranger web site at

Legal requirements. More information on laws and regulations is found in the following documents:

Versaguard MAX Console OEM Guide

2003 F-Super Duty /Excursion Workshop Manual

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100

MaxxForce 7 (2010) Engine Warning & Protection System Navistar, Inc.

International A26 (2017)

GTWY505 Fast Idle, Shift Interlock, I/O Ford E-Series

OPER:03. Questions about Operational Analysis. en-gb. Issue Scania CV AB Sweden

GTWY515, GTWY516* Fast Idle, Shift Interlock, I/O Ford Transit Introduction

POWER LOCK SYSTEMS 8P - 1 POWER LOCK SYSTEMS TABLE OF CONTENTS

ECO3-601/602 EcoStar III * Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications

MaxxForce 11 and 13 ( )

Service Bulletin Buses

DTC P1518 Throttle Actuator Control (TAC) Module Serial Data Circuit

The engine is running. DTC P0351, P0352, P0353, and P0354 run continuously once the above condition has been met.

International A26 (2017)

556L General Motors Passlock Interface Module

CHIME/BUZZER WARNING SYSTEMS

Service Bulletin Buses

Holden VZ 3.6L ECU & Powertrain Interface Module Linking Instructions

FOR AUTOMATIC TRANSMISSION AND DIESEL ENGINE VEHICLES

DATE: 7/29/99. PAGE: 1 of 32

Senior Swing Control Box. Table of Contents

An ISO 9001:2008 Registered Company

The information in these instructions was up to date when it was printed. VBG reserves the right to make technical changes without prior notice.

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

GM PTO. Systems; Part 2 of 2

5 FEATURES DDEC FOR MBE900 AND MBE4000

KEYLESS ENTRY SYSTEM & TIRE PRESSURE MONITOR ACCESSORIES & EQUIPMENT General Motors Corp. - Remote Keyless Entry System

GTWY605 Fast Idle, Shift Interlock, I/O Chevy 610 Van - 6.0L and 6.6L Engines Contact InterMotive for additional vehicle applications.

CA-510a Installation Instructions

Property of American Airlines

Cabling and cable harnesses. General

VOLVO C30, S40 & V50 drive OWNERS MANUAL SUPPLEMENT

Model AS-9234E. Owners Guides

2007 W-SERIES (CHEVROLET & GMC) N-SERIES (ISUZU) 274

An ISO 9001:2015 Registered Company

HL515-B Fast Idle, Lift Interlock Ford Transit

Automated Control Electronics (ACE ) System Operation and Diagnostics


GUARDIAN 401 A - Symptom Flow Chart - Lift Interlock Condition Possible Causes Action No prove out of LED's

xpressstart Mercedes Solution Sprinter Installation Instructions

4.2 Component Identification

MaxxForce 15 (2011) Overview: Idle Shutdown Timer (including Certified Clean Idle) 2011 Navistar, Inc.

Loose Ship Park Assist and Park View System

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

3 Channel Remote Start / Keyless Entry System Installation Instructions

Exterior Lighting Systems Description and Operation. Exterior Lamps. The exterior lighting system consists of the following lamps: The headlamps

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

Parking Brake Indicator Is Flashing

Model PRO 9246CH Installation Manual

Tires are available in a number of sizes and tread patterns dependent on the vehicle usage. Tire sizes are as follows:

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

MaxxForce DT, 9, 10 (2010)


PowerCommand 2100 digital generator set control

Deep Sea Electronics Plc

Removing the engine. General. Tools. Work description. Preparatory work

Sequential manual transmission (SMG) E60. VS-22 je Baugruppe/Group: (044) 10/2003. Introduction

Transcription:

Function Remote engine start is used to start the engine without turning the starter key to the start position, for example by using a switch outside the cab. Function There is also a function called Inhibit remote engine start which is used to inhibit engine start by remote activation. However, the function does not inhibit engine start by the starter lock. WARNING! For safety reasons, it must be possible to shut down the engine in close vicinity to the location where the engine is started. Information on remote engine shutdown is found in the document Remote engine shutdown. Scania CV AB 2016, Sweden 1 (12)

Behaviour Behaviour When remote engine start is activated, the system gives a visual acknowledgement of the start attempt by using the direction indicator lamps. The vehicle has the following acknowledgement signals from the factory: When the activation conditions are fulfilled and the engine starts: The direction indicator lamps flash When the activation conditions are not fulfilled and the engine fails to stary: The direction indicator lamps come on with a steady light The acknowledgement function can be turned off by using SDP3 for bodybuilders (Scania Diagnos and Programmer 3). Scania CV AB 2016, Sweden 2 (12)

Chassis conditions Chassis conditions Preparations from the factory Option Alternative Variant code BCI a functionality With 5837A Remote engine start Prepared 3313B If required Cable harness from cab to frame 7+7+7-pin 2411F Extension cable harness on frame 2 m 3023A 8 m 3023D 12 m 3023C a. Bodywork Communication Interface Information on cable harness from cab to frame and extension cable harnesses on the frame is found in the document Cable harnesses for bodywork functions. Scania CV AB 2016, Sweden 3 (12)

Activation Activation The functions Remote engine start and Inhibit remote engine start are controlled by the BCI control unit. The functions can either be activated by using internal vehicle signals, analogue signals or external CAN network (Controller Area Network). Signal type Type of activation Internal vehicle signal Analogue signal External CAN network Activation method Signal from a factory-fitted function. Signal from a retrofitted function. Connected by the bodybuilder via connector C259 in the bodywork console. CAN message Information on CAN messages is found in the document External CAN Communication Specification. Scania CV AB 2016, Sweden 4 (12)

Activation using internal vehicle signals and analogue signals Different functions in the vehicle are factors that affect the activation. Activation Internal signals in the vehicle come from a function fitted at the factory. Examples of factors that can affect the activation by using internal signals are applied parking brake or activated power take-off. Use analogue signals when a factor does not generate an internal signal as above. Examples of factors that can affect the activation by using analogue signals are an activated switch in the instrument panel or a deactivated sensor in the bodywork. Define when and how the activation is to take place by using BICT (Bodywork Interface Configuration Tool) and SDP3 for bodybuilders: 1. Create a logic diagram in BICT that defines which factors shall affect the activation. 2. Define parameters in SDP3 for bodybuilders which state the conditions for how and when the different factors shall affect the activation. The logic diagram is transferred, together with the parameters, to the vehicle s BCI control unit using SDP3 for bodybuilders. More information on BICT is found in the document BCI, Bodywork Communication Interface. Scania CV AB 2016, Sweden 5 (12)

Activation by using external CAN network Activation When a vehicle is equipped with BCI functionality, a connection to the external CAN network via connector C493 for bodywork is included. The external CAN network is activated by using SDP3 for bodybuilders. A CAN message defines when and how the function is to be activated. Activation conditions Components and cable harnesses for the activation conditions are included in the factory-fitted options required for connection of the function. Information on the options is found under the heading Chassis conditions. The following activation conditions must be fulfilled to allow Remote engine start to be activated: The Inhibit remote engine start function deactivated Starter key in drive position Engine shut down No engine shutdown functions activated Parking brake activated Drive mode selector and gearbox in neutral position The Inhibit remote engine start function has no activation conditions. The Remote engine start switch must be spring-loaded. When starting the engine, the starter button must be held depressed for a certain time after the engine has started. If the starter button is released too quickly, the start attempt will be interrupted and the engine stops. The default factory setting is that the starter button must be held depressed for 1 second after the engine has started. The time can be changed by using SDP3 for bodybuilders. Scania CV AB 2016, Sweden 6 (12)

If the starter button is held depressed for longer than 10 seconds after the engine has started, the engine shuts down. Activation When a start attempt is interrupted, either the stop symbol in the instrument cluster s main display or one of the indicator lamps in the instrument cluster comes on depending on the vehicle s configuration. Activation conditions with or without EXT switch With EXT switch The EXT switch must be activated after the starter key has been turned to the drive position. Only then can the function be activated. Without EXT switch Activation of the function is not dependent on the EXT switch. Scania CV AB 2016, Sweden 7 (12)

Parameters that can be adjusted by using SDP3 for bodybuilders Parameters that can be adjusted by using SDP3 for bodybuilders Contact a Scania dealer if access to SDP3 for bodybuilders is missing. Adjust the parameters under Functions in SDP3 for bodybuilders. Parameter Explanation Possible value From factory Group Remote engine start, visual confirmation Confirms both successful and failed engine starts. With With Remote engine start, verification period EXT switch a a. The parameter setting affects all functions that are dependent on the EXT switch. More information on the parameters is found in the following documents: Parameters Powertrain Parameters Bodywork adaptation Defines for how long the Remote engine start switch must be held depressed for the engine not to be shut down when the switch is released. Controls whether the EXT switch should be active or not Without 0.5-5 s 1 s Without Powertrain With With Bodywork adaptation Without Scania CV AB 2016, Sweden 8 (12)

Connection Connection The following example of connections applies to both the Remote engine start and Inhibit remote engine start functions. Example of an analogue connection using BICT This description shows a connection inside the cab with activation to +24 V or ground. Information on how to make the connection with extension cable harness on the chassis frame is found in the document Cable harnesses for bodywork functions. Proceed as follows: 1. Connect the activation cable to any position in connector C259. 2. Assign function to the selected position using BICT. 3. Transfer the logic diagram from BICT to the vehicle s BCI control unit using SDP3 for bodybuilders. The function is ready for activation. Scania CV AB 2016, Sweden 9 (12)

Connection Part information and connection points 1 Pos. Designation Description 1 Fuse 5 A +24 V Fitted in the bodywork central electric unit by the bodybuilder. 2 3 2 For example, a switch Connected from +24 V or ground to any position in C259. 3 Cable Minimum permitted cable cross section is 0.75 mm². C259 4 C259 Fitted by the bodybuilder. 4 C259 Located in the bodywork console. Connect the cable to the contact housing. 5 Ground Ground rail, G70, in bodywork central electric unit. Activation by +24 V. 1 10 373 296 The parts are available from Scania dealers. Signal type Activation method 5 Analogue From +24 V to selected position in C259 or Grounding of selected position in C259 2 3 C259 4 C259 1-10 Activation by grounding. 373 297 Scania CV AB 2016, Sweden 10 (12)

Example of a logic diagram in BICT Connection 1a Vehicle function 2 Activate remote engine start 1b 2 C259-X BCI master, C259-X, high ( ) Activate remote engine start 377 355 Pos. Description Options 1a and 1b Factors that will affect the activation of the function. 1a. A specific function in the vehicle. 1b. A signal via optional position in C259 with connection to the BCI control unit. Settings: Position in C259, 1-10 High or low signal Rewrite the text in the grey box so that it is clear from where the signal comes, for example a specific switch or sensor. 2 The function to be activated if all conditions are met. Activate Remote engine start or Inhibit remote engine start. The behaviour is configured by using SDP3 for bodybuilders. Scania CV AB 2016, Sweden 11 (12)

Example of connection via external CAN network Connection To be able to make the connection via external CAN network, the following is required: The vehicle is equipped with BCI functionality. The parameter for external CAN network is activated. Connect the external CAN network directly to connector C493. More information on connection to C493 is found in the document Connector C493 BCI-controlled bodywork functions. C493 Signal type Message CAN CAN message More information is found in the following documents: CAN interface for bodywork External CAN Communication Specification General information on CAN Installing expansion unit Cable harness for bodywork functions Activation via external CAN network. 373 298 Scania CV AB 2016, Sweden 12 (12)