Mounting and Operating Instructions EB 8392 EN. Series 3710 Type 3710 Reversing Amplifier

Similar documents
Type 3379 Pneumatic Actuator. Mounting and Operating Instructions EB 8315 EN

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

Type 3271 Pneumatic Actuator. Actuator area: cm². Mounting and Operating Instructions EB EN

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

Strainers with flanged connections Type 2 N Type 2 NI. Type 2 N/2 NI Strainers. Mounting and Operating Instructions EB 1015 EN

Series 250 Pneumatic Control Valves Type and

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Mounting and operating instructions EB 8220 EN. Pneumatic Butterfly Valve Type 3335/AT and Type 3335/3278. Fig. 2 Type 3335/AT

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Series V2001 Valves Clean Tech Type 3321CT Globe Valve with pneumatic actuator

Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175 and 750 cm². Type 3271 Type Mounting and Operating Instructions EB EN

Series 240 Type 3351 Pneumatic On/off Valve

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

Pneumatic Controller for Temperature. Type Pneumatic Controller for Temperature. Type Mounting and Operating Instructions EB 7065 EN

Type 3273 Hand-operated Actuator Type 3273 Side-mounted Handwheel

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

System 6000 Electropneumatic Converter for Direct Current Signals i/p Converter Type 6126

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Pneumatic Rotary Actuator Type 3278

Type Electronic Limit Switch

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Mounting and operating instructions EB 8093 EN. Series 240 Pneumatic Control Valve for Cryogenic Temperatures. Type and

Series 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve

T 8053 EN Type and Type Pneumatic Control Valves Type 3252 High-pressure Valve

Series 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Series 240 Type Gas and Type Gas Automatic Shut-off Valves for Gases (valve class D)

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Pneumatic Control Valve Assembly Type 3331/3278

Mounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Series 240 Types PSA, -7 PSA, -9 PSA Pneumatic Control Valves Type 3241 PSA Globe Valve

Pneumatic Shut-off Butterfly Valve Type 3335/BR 31a

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Type 4746 Electric or Pneumatic Limit Switch

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

Mounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Series 3730 Electropneumatic Positioner Type

T 8321 EN Type 3278 Pneumatic Rotary Actuator

Pneumatic Butterfly Valve Type 3335 / AT

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Series 240 Pneumatic Control Valve Type and Type Three-way Valve Type 3244

Electric Actuators Type SAM Linear Actuator

Data Sheet T EN

Series W&T Pneumatic Control Valve Type RVG Globe valve and angle valve

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Mounting and operating instructions EB EN. Differential Pressure and Temperature Regulator with Flow Limiter Type 2479/2430 K

Mounting and Operating Instructions EB 5868/5869 EN

Series 240 Type 3349/3379 Pneumatic Control Valve Type 3349 Aseptic Angle Valve

Valve Series V2001 Three-way Valve Type 3323

Series 430 Type 3430 Pneumatic Indicating Controller for Temperature with Capillary Sensor Type 3432 Controller Station Type 3436 Transmitter Module

Pneumatic Butterfly Valve Pfeiffer Type BR 14b/AT

ANSI version. The valve closes when the differential pressure rises

Limit Switch Type 3776

Series 240 Type and Type Pneumatic Control Valves Type 3347 Hygienic Angle Valve

Series 240 Pneumatic Control Valve Type DWA, -7 DWA, -9 DWA Globe Valve Type 3241 DWA

T EN Type 3347/3379 Pneumatic Control Valve Type 3347 Hygienic Angle Valve

Self-operated Temperature Regulators Type 1u Temperature Regulator

Mounting and Operating Instructions EB EN. Type 3271 Pneumatic Actuator. Actuator area: 1000 cm². Translation of original instructions

Series 240 Pneumatic On-off Valve Type 3351

Mounting and Operating Instructions

Maxifluss Rotary Plug Valves VETEC Types 72.3/R and 72.4/R

Maxifluss Rotary Plug Valves VETEC Types 73.3/M and 73.7/M

Maxifluss Rotary Plug Valve. VETEC Type 72.1/R, Type 72.3/R and Type 72.4/R

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Pressure Reducing Valve Type 2114/2415

Typetested for liquid fuels and liquefied petroleum gas (LPG) in the liquid phase (see Data Sheet T 8022 EN) Version according to ANSI standards

Mounting and Operating Instructions EB EN. Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175v2, 350v2, and 750v2 cm²

Series 240 and 250 Valves with perforated plug

Mounting and operating instructions EB Pneumatic Control Valve Type and Type Globe Valve Type 3522 ANSI Class 300

System 6000 Electropneumatic Converters for DC ranges I/P Converter Type 6102 Type 5288

Series 3331 Pneumatic Control Butterfly Valve Type 3331/BR 31a

Series 240 Pneumatic Control Valves Type and Type Three-way Valve Type 3244

Differential Pressure and Flow meters Accessories for the Media Series

Self-operated Temperature Regulators Type 1u Temperature Regulator

Electronic Limit Switch Type

Pneumatic Control Valve Type and Type Micro-flow Valve Type 3510

Series 240 Pneumatic Control Valve Type and Type Globe Valve Type 3241

Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767

Series 3730 Type Electropneumatic Positioner. Fig. 1 Type Mounting and Operating Instructions EB EN ( )

Type 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN

Series 240 Pneumatic Control Valve Type and Type Globe Valve Type 3241

Transcription:

Series 3710 Type 3710 Reversing Amplifier Type 3710 Reversing Amplifier in standard version with pressure gauges for Y 1 and Y 2 Mounting and Operating Instructions EB 8392 EN Edition December 2012

Note on these mounting and operating instructions These mounting and operating instructions (EB) assist you in mounting and operating the device safely. The instructions are binding for handling SAMSON devices. For the safe and proper use of these instructions, read them carefully and keep them for later reference. If you have any questions about these instructions, contact SAMSON's After-sales Service department (aftersalesservice@samson.de). Referenced documentation The documents for the devices used in combination with the reversing amplifier apply in addition to these mounting and operating instructions. The mounting and operating instructions for all supplied devices are included in the delivery. The latest versions of the documents are available on our website at www.samson.de > Product documentation. Definition of signal words DANGER! Hazardous situations which, if not avoided, will result in death or serious injury WARNING! Hazardous situations which, if not avoided, could result in death or serious injury NOTICE Property damage message or malfunction Note: Additional information Tip: Recommended action 2 EB 8392 EN

Contents 1 General safety instructions...4 2 Markings on the device...5 2.1 Article code...5 2.2 Nameplate...5 3 Design and principle of operation...6 3.1 Technical data...7 3.2 Materials...7 4 Attachment to positioners and limit switches...8 4.1 Attachment to positioners and limit switches (device index.05 and higher)...8 4.2 Attachment to positioners and limit switches (below device index.05)...8 4.3 Attachment to Type 3725 Positioner...8 4.4 Note on attachment to rotary actuators according to VDI/VDE 3845...10 4.5 Attachment with Type 4708-54 Supply Pressure Regulator...11 4.5.1 Note on attachment to Type 3275 Piston Actuator...12 5 Pneumatic connections...12 5.1 Pressure gauges...12 6 Malfunctions...14 7 Accessories for Type 3710...16 8 Dimensions in mm...17 EB 8392 EN 3

General safety instructions 1 General safety instructions For your own safety, follow these instructions concerning the mounting, start-up, and operation of the device: The device is to be mounted, started up or operated only by trained and experienced personnel familiar with the product. According to these mounting and operating instructions, trained personnel refers to individuals who are able to judge the work they are assigned to and recognize possible dangers due to their specialized training, their knowledge and experience as well as their knowledge of the applicable standards. To avoid damage to any equipment, the following also applies: Proper shipping and storage are assumed. 4 EB 8392 EN

Markings on the device 2 Markings on the device 2.1 Article code Reversing amplifier Type 3710-1 x x 1 0 x x 0 Housing material Aluminum 0 Stainless steel 1 3 Connecting thread ISO 228/1-G ¼ 1 ¼-18 NPT 2 Ambient temperature range 25 to +80 C 0 50 to +80 C 1 3 60 to +80 C 2 3 Degree of protection IP 65, filter check valve made of polyamide 2 IP 65, filter check valve made of stainless steel 1.4305 3 2.2 Nameplate 3710-3- Var.-ID 1 2 3 4 Made in France 1 Article code 2 Production ID 3 Permissible ambient temperature 4 Configuration ID EB 8392 EN 5

Design and principle of operation 3 Design and principle of operation The reversing amplifier allows double-acting pneumatic actuators to be operated using single-acting positioners or limit switches. The positioner creates an output signal pressure Y 1, to which the air pressure Y 2 is added. The reversing amplifier uses the supply pressure Z as auxiliary power. The following rule applies: Y 1 + Y 2 = Z Example: Y 1 of the positioner Supply pressure Z Resulting Y 2 1 bar 6 bar 5 bar Positioner Reversing amplifier Supply air (max. 6 bar) Z Z Output 38 Supply 9 Y 1 Y 1 Y 2 Chamber 1 1) Pneumatic rotary actuator (doubleacting) Pressure is added to Y 1 to create 6 bar Chamber 2 2) Vent plug (IP 65) C Y 1 Y 2 Supply air Output signal pressure Resulting (opposing) signal pressure 1) Air chamber 1 opens the valve when the pressure rises 2) Air chamber 2 closes the valve when the pressure rises Fig. 1: Schematic diagram of Type 3710 Reversing Amplifier 6 EB 8392 EN

Design and principle of operation 3.1 Technical data Type 3710 Reversing Amplifier Permissible supply pressure 6 bar K V to fill the actuator with air 0.11 coefficient to vent the actuator 0.12 Leakage Z to Y 2 20 l/h when Y 2 = 0 bar and Z = 6 bar Y 2 to vent plug 40 l/h when Y 1 = 0 bar and Y 2 = 6 bar Connections ¼-18 NPT ISO 228/1-G ¼ Degree of protection IP 65 Compliance Permissible ambient temperature 25 to +80 C 13 to +176 F Low-temperature version: 50 to +80 C 58 to +176 F 60 to +80 C 67 to +176 F Weight 0.5 kg 1.2 kg for stainless steel version 3.2 Materials Materials Housing and cover Diaphragm plate Seat and plug Diaphragms Powder-coated aluminum Special version in stainless steel 1.4404 Aluminum, yellow chromated Brass Silicone rubber FVMQ PTFE for low-temperature version EB 8392 EN 7

Attachment to positioners and limit switches 4 Attachment to positioners and limit switches The description in section 4.1 and 4.2 applies to the following devices: Type 3730 Positioner Type 3731 Positioner Type 3766 Positioner Type 3767 Positioner Type 3768 Limit Switch Check device index before attachment. Note: See the last two figures of the configuration ID written on the nameplate for the device index. 4.1 Attachment to positioners and limit switches (device index.05 and higher) 1. Fasten the reversing amplifier directly to the positioner/limit switch using two M5 screws. On mounting the device, make sure that the two O-rings (1.2 in Fig. 2 left) are inserted properly into their groove. Tip: If you lose any O-rings for the reversing amplifier, you can order more (order number 8421-9064). 4.2 Attachment to positioners and limit switches (below device index.05) Required accessories: Connecting plate (1400-9621) (2 in Fig. 2) 1. Screw the special nuts (1) included in the accessories for the connecting plate (2) into the holes of the positioner. 2. Insert the O-rings (1.2) into the grooves of the connecting plate (2). Slide the hollow bolts (1.3) into the threaded ports and fasten tight. 3. Fit O-rings (1.2) on the reversing amplifier. Place it on the connecting plate (2) and fasten tight. 4.3 Attachment to Type 3725 Positioner Required accessories: Connecting plate (1402-0512) (1 in Fig. 3) 1. Fasten the connecting plate (1) between the positioner and the reversing amplifier using two M5 x 50 screws (2). Note: The screws supplied with the connecting plate have a TORX PLUS profile and must be tightened using a suitable tool. 8 EB 8392 EN

Attachment to positioners and limit switches 1.4 1.2 Y 1 Output Supply 1.4 Y 2 1 Special nuts 1.2 O-rings 1.3 Hollow bolts 1.4 Fastening holes 2 Connecting plate 1 1.2 2 1.3 1.2 Attachment to Types 3730, 3731, 3766, and 3767 as well as Type 3768 Limit Switch below device index.05 Fig. 2: Attachment to Types 3730, 3731, 3767, and 3766 Positioners as well as Type 3768 Limit Switch Type 3725 Positioner 1 Reversing amplifier 2 1 Connecting plate 2 M5 x 50 screws (screw head with TORX PLUS profile) Fig. 3: Attachment to Type 3725 Positioner EB 8392 EN 9

Attachment to positioners and limit switches 4.4 Note on attachment to rotary actuators according to VDI/VDE 3845 The description applies to the following devices: Type 3730 Positioner (angle of rotation >90 ) Type 3766 Positioner Type 3767 Positioner Type 3768 Limit Switch For the attachment of the reversing amplifier to the above listed devices with mounting kit 1400-8815, remove the vent plug (6) from the intermediate piece (5) and insert into the positioner (see Fig. 4): 1. Place the O-ring (3) onto the screw plug (1). 2. Screw the screw plug (1) into the vent opening of the intermediate piece (5). 3. Thread the threaded bushing (2) and retaining washer (4) into the free cable gland of the positioner. 4. Screw vent plug (6) into the threaded bushing (2). 5. Fasten the reversing amplifier directly to the positioner/limit switch using two M5 screws. Note: The vent plug included in the mounting kit (1400-8815) has IP 54 degree of protection. For a higher degree of protection, select a suitable vent plug from the accessories listed in section 7. 6 2 4 1 Screw plug 2 Threaded bushing 3 O-ring 4 Retaining washer 5 Intermediate piece 6 Vent plug 5 31 Fig. 4: Relocating the vent plug on attachment to rotary actuators according to VDI/VDE 3845 10 EB 8392 EN

Attachment to positioners and limit switches 4.5 Attachment with Type 4708-54 Supply Pressure Regulator Required accessories: Bolts with special nuts (1400-7806) (1 in Fig. 6) 1. Screw special nuts (1) into the holes in the reversing amplifier. 2. Insert gasket (3) into the recess of the supply pressure regulator and slide the special hollow bolts (2) into the holes for Output and Supply. 3. Position reversing amplifier and fasten using the hollow bolts (2). Fig. 5: Reversing amplifier with supply pressure regulator mounted onto positioner and rotary actuator 1 1 Special nuts 2 Hollow bolts 3 Gasket 3 2 Fig. 6: Mounting the reversing amplifier onto Type 4708-54 Supply Pressure Regulator EB 8392 EN 11

Pneumatic connections 4.5.1 Note on attachment to Type 3275 Piston Actuator When mounting the reversing amplifier with the Type 4708-54 Supply Pressure Regulator and positioner onto a Type 3275 Piston Actuator: Mount the positioner in such a manner that the pneumatic connections are located on the left side (Fig. 7). The supply pressure regulator can only be mounted onto the reversing amplifier in this mounting position. 5 Pneumatic connections The air connections are designed either with ¼-18 NPT or G ¼ threads. Customary fittings for metal or copper tubing or plastic hoses can be used. Signal pressure connections See dimension diagram on page 15 for connections Y 1 : Connect output Y 1 to the signal pressure connection on the actuator that causes the valve to open when the pressure rises. Y 2 : Connect output Y 2 to the signal pressure connection on the actuator that causes the valve to close when the pressure rises. 5.1 Pressure gauges The Type 3710 Reversing Amplifier is designed with connections for two pressure gauges on both sides. The connections are sealed with screw plugs G 1 / 8 when a pressure gauge is not installed. Y 1 Fig. 7: Type 3710 Reversing Amplifier, Type 4708-54 Supply Pressure Regulator with Type 3730 Positioner mounted on Type 3275 Piston Actuator Fig. 8: The pressure gauges indicate the signal pressure at the outputs. Y 2 12 EB 8392 EN

Malfunctions Technical data Pressure gauge Ø 40 mm Indicating 0 to 6 bar 0 to 90 psi range Connection G 1 /8 Materials Housing Measuring unit and connection Stainless steel, device free of copper Stainless steel, free of copper Nickel-plated brass connection Mounting the pressure gauges 1. Remove the screw plug G 1 / 8 from the reversing amplifier. 2. Insert the seals supplied with the reversing amplifier. 3. Screw the pressure gauges into the corresponding connections. 4. Tighten the lock nuts of the pressure gauges leaving a 2 to 3 mm gap between the lock nut and pressure gauge s square end. Always use screw plugs G 1 / 8 to seal any unused pressure gauge connections. 6 Malfunctions The reversing amplifier is maintenance-free. If there is leakage between reversing amplifier and pneumatic connections, check the pipe fittings for leaks. If there is leakage between reversing amplifier and positioner, check correct seating of O-rings and replace them with new ones, if necessary. In case of other malfunctions, contact SAMSON's After-sales Service department: aftersalesservice@samson.de EB 8392 EN 13

Accessories for Type 3710 7 Accessories for Type 3710 Accessories Order number O-rings (included in the scope of delivery). See Fig. 2 on page 9. 8421-9064 Accessories for attachment to Type 3725 Positioner Connecting plate (including two self-tapping screws M5 x 50) 1402-0512 Pressure gauge (order number applies to one piece) Pressure gauge 0 to 6 bar/psi/kpa; completely made of stainless steel, 1402-1337 including pressure compensation element Pressure gauge 0 to 6 bar/psi/kpa; stainless steel/nickel-plated brass connection, including pressure compensation element 1402-1338 Seal with spacer 1099-4305 Mounting kit for Type 4708-54 Supply Pressure Regulator with Type 3710 Reversing Amplifier Bolts with special nuts 1400-7806 Filter check valves IP 65, 1.4404 1790-7253 NEMA 4, polyamide 1790-9645 NEMA 4, 1.4404 1790-9646 IP 65, polyamide 1790-7408 Connecting plate for older models of Types 3766, 3767, and 3780 Positioner as well as Type 3768 Limit Switch (below device index.05) Connecting plate 1400-9621 14 EB 8392 EN

Dimensions in mm 8 Dimensions in mm Type 3710 Reversing Amplifier with pressure gauges, mounted on Type 3730 Positioner 52 Output Y 1 Supply (9) 90 86 56 80 30 86 Ø101 80 130 166 Output Y 2 Output Y 1 Output Y 2 164 164 15 Mounted using a connecting plate (order no. 1400-9621) onto Type 3766, 3767 or Type 3780 Positioners (below device index.05, see section 4.2) Type 3710 Reversing Amplifier with pressure gauges, mounted on Type 3725 Positioner 22 108 29.5 M20 x 1.5 87 EB 8392 EN 15

SAMSON AG MESS- UND REGELTECHNIK Weismüllerstraße 3 60314 Frankfurt am Main, Germany Phone: +49 69 4009-0 Fax: +49 69 4009-1507 samson@samson.de www.samson.de EB 8392 EN 2017-12-21 English