Kuhlman Electric Corporation Volt Instrument Transformers

Similar documents
Kuhlman Electric Corporation Volt Instrument Transformers

Volt Instrument Transformers

Kuhlman Electric Corporation. Engineered Designs Instrument Transformers

REFERENCE GUIDE INSTRUMENT TRANSFORMERS INDOOR / OUTDOOR CAST RESIN CONSTRUCTION

Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

Technical Specification for Pole Mounted Capacitor Rack

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability.

Type IMC Indoor current transformer

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

Instrument Transformer Reference. Meter and Relay Applications for the Electrical Industry

TYPE BLT DISCONNECT SWITCHES

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

Howard Industries. Single-Phase Step

Advance 27 ANSI 27 kv switchgear

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

25 kv Apparatus Bushings

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

Q pole Pole Mounted Capacitor System

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Technical Specification For Outdoor Substation Harmonic Filter Banks

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

15 kv and 25 kv Thru-Bushings

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

MAX-VH. Vertical Hollow Shaft Motors

35-kV Safefront 200 Amp SuperWell Primary Capacitor Station Pad-Mounted Outdoor

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

CURRENT TRANSFORMER MODEL N. SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.25 x 0.50 SLOT (2 PLACES)

Excitation system is of Static Silicon Excitation System, including excitation transformer, thyristors, and AVR.

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

Midwest Dry Type Transformers

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

A 1.2 kv class externally removable secondary bushing

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

IEC Separable Connectors 17.5 kv/24 kv, 630A

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

TYPE V CENTER BREAK SWITCH

Product Specifications for Aluminum Vertical Break Switches

dfdf 34.5 kv and 69 kv, Type O Plus C II Condenser Bushings Technical Guide

Power Voltage Transformers for Air Insulated Substations

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Solid Dielectric, Single Phase Recloser

Bushings for High Voltage AC Applications

Industrial Control Transformers

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

Unit Substation Transformers 5 and 15 KV Class

Three-Phase Pole Mounted Recloser

Switchgear Skid, C1192

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

Features and Benefits

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Design Standard. Purpose: Design Standard:

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Load Break Switch Type LBOR-II, Oil Immersed PTAT-LIR975 IZUA Technical Guide Nut Mount Weld Mount

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

JOSLYN. Underground Cable Accessories. Table of Contents. JPT/JIPT Polymer Terminations. ShrinkTite Sealing Kits. Easy-On II Terminations

Submersible Vacuum Fault Interrupters

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Types VSA12, VSA12B, VSA16, VSA20, and VSA20A; three-phase; air-insulated; electronically controlled recloser

Cobra-S. Catalog Cobra-S

Distribution transformers Efficiency over life-cycle

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1

EMPAC Metal enclosed capacitor bank for wind applications

Copper Double Break Switch

M-Force three-phase switch

15-kV Live Terminal Primary Metering Station Pad-Mounted Outdoor

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

43-SDMS-01 SPECIFICATIONS FOR

CITY OF MARYVILLE ELECRIC DEPARTMENT Maryville, Tennessee SPECIFICATIONS FOR 15KV POWER CIRCUIT BREAKERS. September 2018

HPS EnduraCoil. Cast Resin Transformer

Publication No.: PSG

Transcription:

Kuhlman Electric Corporation 34500 Volt Instrument Transformers

34500 Volt Table of Contents Description Model Page Wound, Dry-Type VT Y (High Accuracy available) PTT-200-9710(H) 3-4 Wound, Oil-Filled VT ZZ, Distribution Class (High Accuracy available) SPOF-200 (DB) 5-6 Wound, Oil-Filled VT ZZ, Substation Class (High Accuracy available) POF-200 (DB) 7-8 Wound, Dry-Type CT Standard Range (High Accuracy available) BB-34-975(H) 9-10 Wound, Dry-Type CT Extended Range BB-34-976 11-12 4 ½ Window CT Single, Dual & Multi Ratio (High Accuracy available) LG(X)-34-879 13-14 Wound, Oil-fi lled CT (High Accuracy available) COF(CXM)-200 15-16 Wound, Dry-Type, Single Phase Metering Unit KM-34-976 17-18 Wound, Oil-Filled, Single Phase Metering Unit (High Accuracy available) JS(JXM)-200 19-20 Wound, Oil-Filled, Three Phase Metering Unit (High Accuracy available) MVCT(MXM)-200 21-22 Wound, Dry-Type, Three Phase CT/VT Metering Rack (High Accuracy available) ME-034 23-24 Wound, Dry-Type, Three Phase Metering Unit Metering Rack MK-34 25-26 2

SPOF 200 (DB) Voltage Transformer Outdoor 34.5kV, 200kV BIL, Single & Dual Ratios (w/ Tertiary) Oil-Filled, Wound Type, Metering/Relaying application The SPOF-200 (DB) outdoor voltage transformer is rated for use on 34,500 volt systems with 200kV BIL. Primary voltage ratios are available from 140:1 to 520:1 for use on 34,500 volt systems, at 60 Hertz (Hz). This oil-fi lled voltage transformer will operate with high accuracy for metering or relay applications. 34500 Volt mechanical description The tank is a standard distribution transformer tank made of heavy gauge sheet steel with a seam welded bottom plate and a dome shaped cover. The tank is washed and coated with anticorrosive iron phosphate and then fi nished with a Munsel 70 Gray bakedon electrostatic polyester powder. The primary bushing(s) are high strength porcelain with tin plated bronze, eye bolt terminal(s) that accept #8 - #2 AWG conductors and are locked with silicon bronze locking hardware. The secondary terminals consist of a feed thru block with ¼ -20 copper studs and associated hardware located inside a removable terminal box with three (3) 1 ½ NPT conduit hubs. The ground terminal is a ½ -13 pad. The unit is fi tted with a pressure relief valve. accuracy performance The SPOF-200 (DB) will operate with 0.3 Class accuracy for metering applications with burdens of 0, W, X, M, Y, Z and ZZ. Upon request, 0.15 metering accuracy is available for burdens of 0, W, X, M, Y and Z, as well as 0.3 ZZ. The transformer is accurate from 90% to 110% of rated primary voltage. mounting The SPOF is designed for mounting on poles or substation structures in an upright position with ANSI type A hanger brackets or optional mounting feet. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Additional tests include dissipation and partial discharge tests. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 135% of the nominal system voltage. options The SPOF is available in single or double bushing models, with NEMA 4-hole Primary Terminal(s), Mounting Feet, a 5kV H 0 Bushing, Stainless Steel Tank, Oil Level Gauge, Oil Drain Valve, and/or -50 C oil. Contact factory for other needs. ORDERING INFO FOR SPOF-200 (DB) Ratio Primary Secondary Catalog Number 1 Bushing 2 Bushing Accuracy/ HIGH ACCURACY SPOF-200 (DB) Catalog Number Accuracy/ 127/220:1:1 15240 120/69.3 & 120/69.3 G830220TA -- 0.3 0 to Z/ZZ Add 0.15 0 to Y/Z 140/240:1:1 16800 120/70 & 120/70 G830240TA -- 0.3 0 to Z/ZZ AAEW to 0.15 0 to Y/Z 175/300:1:1 20125 115/67.08 & 115/67.08 G830300TA G840300TA 0.3 0,W,X,M,Y,Z,ZZ the end of 0.15 0 to Z, 0.3 ZZ 300/520:1:1 34500 115/66.4 & 115/66.4 -- G840520TA 0.3 0,W,X,M,Y,Z,ZZ the std cat # 0.15 0 to Z, 0.3 ZZ - Thermal (Typical): 5000VA. - Overvoltage : 1.1x cont., 1.9x 8 hours (single bushing designs). 5

34500 Volt SPOF 200 (DB) Voltage Transformer 6 NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS.

POF 200 (DB) Voltage Transformer Outdoor 34.5kV, 200kV BIL, Single & Dual Ratios (w/ Tertiary) Oil-Filled, Wound Type, Metering/Relaying application The POF-200 (DB) outdoor voltage transformer is rated for use on 34,500 volt systems with 200kV BIL. Primary voltage ratios are available from 140:1 to 520:1 for use on 34,500 volt systems, at 60 Hertz (Hz). This oil-fi lled instrument voltage transformer will operate with high accuracy for metering or relay applications. 34500 Volt mechanical description The tank and expansion chambers are steel plate, pressure and vacuum tight and hermetically sealed at the factory to prevent breathing and oil contamination. Expansion chambers allow for the expansion/contraction of oil for temperature and load fl uctuations. Tank components are washed and coated with anticorrosive iron phosphate and then fi nished with ANSI 70 Gray baked-on electrostatic polyester powder. The primary bushing(s) are ANSI 70 Gray, high strength porcelain with a high degree of stability for transportation and seismic withstand. The primary terminal(s) are stainless steel NEMA 4-hole pad(s). The secondary terminals are ¼ -20 copper studs with associated hardware located inside a removable terminal box with three (3) 1 ½ NPT conduit hubs. The ground terminal is a stainless steel NEMA 2-hole pad. The unit is fi tted with a 5kV H 0 Bushing (for single bushing designs), pressure relief valve, oil level indicator, ¾ oil fi ll plug, and ½ drain valve. accuracy performance The POF-200 (DB) will operate with 0.3 Class accuracy for metering applications with burdens of 0, W, X, M, Y, Z and ZZ. Upon request, 0.15 Class metering accuracy is available with burdens of 0, W, X, M, Y and Z, as well as 0.3 ZZ. The transformer is accurate from 90% to 110% of rated primary voltage. mounting The POF is designed for mounting on substation structures with mounting feet in an upright position. Single bushing units can be mounted on poles with ANSI type A hanger brackets. NOTE: Must be installed per NESC electrical clearances. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Additional tests include dissipation and partial discharge tests. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 135% of the nominal system voltage. options The POF is available in single or double bushing models, with Extra Creep Bushing(s), Polymer Bushing(s), Stainless Steel Tank, and/or -50 C oil. Contact factory for other needs. ORDERING INFO FOR POF-200 (DB) Ratio Primary Secondary Catalog Number 1 Bushing 2 Bushing Accuracy/ HIGH ACCURACY POF-200 (DB) Catalog Number Accuracy/ 138/240:1:1 16560 120/69 & 120/69 *G710240TA -- 0.3 0 to Z/ZZ 0.15 0 to Y/Z Add 16560 120/69 & 120/69 138/240:1:1 -- **G820240TA 0.3 0,W,X,M,Y,Z AAEW 0.15 0 to Y, 0.3 Z or 28800 or 120 & 120 to the 175/300:1:1 20125 115/67.08 & 115/67.08 G710300TA G820300TA 0.3 0,W,X,M,Y,Z,ZZ end 0.15 0 to Z, 0.3 ZZ 175/300:1:1:1 20125 (3) 115/67.08 TBD TBD 0.3 0,W,X,M,Y,Z,ZZ of the 0.15 0 to Z, 0.3 ZZ 300/500:1:1 34500 115/69 & 115/69 -- G820500TA 0.3 0,W,X,M,Y,Z,ZZ standard 0.15 0 to Z, 0.3 ZZ catalog 175/300:1 20125 115/67.08 & 115 0.3 0,W,X,M,Y,Z 0.15 0 to Y, 0.3 Z -- G820520TA number & 300/520:1 or 34500 or 115 & 115/66.4 0.3 0,W,X,M,Y,Z,ZZ 0.15 0 to Z, 0.3 ZZ - Thermal (Typical): 5000VA. Dual primary units (4000VA L-G, 7000VA L-L). - Overvoltage : 1.1x cont., 1.9x 8 hours (single bushing desings). - IC Approval *(AE-0888), **(AE-0752). 7

34500 Volt POF 200 (DB) Voltage Transformer 8 NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS.

LG(X) 34 879 Current Transformer Outdoor 34.5kV, 200kV BIL, Single, Dual & Multi Ratios Molded Resin, Window Type, Metering/Relaying 34500 Volt application The LG(X)-34-879 outdoor, window-type current transformer is rated for use on 34,500 volt systems with 200kV BIL. Primary current ratios are available from 200:5 to 10,000:5 at 60 Hertz (Hz) with a of up to 4.0. This dry-type, solid-cast current transformer will operate with high accuracy for metering or relay applications. mechanical description The core and coil assembly is wound and encapsulated in a molded cast resin with a 4 ½ window porcelain primary bushing to provide high withstand capabilities. The high strength porcelain has a semi conductive interior with a pigtail lead to be connected to the primary conductor to equalize the voltage and prevent radio interference and corona. An optional primary bus bar with NEMA 4-hole pads can also be provided. The secondary terminals are ¼ -20 copper studs with associated hardware located inside a removable terminal box with two (2) 1 NPT conduit hubs. accuracy performance The LG-34-879 will operate with 0.3 Class accuracy for metering with burdens of B0.1 to B1.8 and up to C800 for some relay applications. The transformer is accurate through its, and can be used continuously to this level. The LGX- 34-879 will operate with 0.15 Class high accuracy for metering applications with burdens of B0.1 up to B1.8. The transformer maintains 0.3 accuracy from 1% of I nom through its, and can be used continuously to this level (for 0.15 accuracy range, see ratings specifi c to each ratio). mounting The LG is designed for mounting in the upright or underhung position with the tube horizontal, or in the cantilever position with the tube vertical. CAUTION: Do not mount in the cantilever position with the tube horizontal, the base plate can collapse. Mounting holes are punched in the aluminum base plate. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. The unit is tested above operating voltage for traces of corona. A corona free label is bonded to the completed transformer as a guarantee of trouble-free service. options The LG is available with a primary bus bar kit or conductive bird guards to prevent foreign objects from entering the porcelain window. The unit can be offered in single, dual or multiple core designs. Contact factory for other needs. ORDERING INFO FOR LG-34-879 Catalog Accuracy/ Ratio Number Metering Relay HIGH ACCURACY LGX-34-879 Catalog Number 0.15/0.3 @ 0.15/0.3 Acc Range 200:5 G092015S159-1 0.3 B0.1 C150 2.0 -- -- -- -- 300:5 G093015S209-1 0.3 B0.2 C200 2.0 -- -- -- -- 400:5 G094015S309-1 0.3 B0.5 C300 2.0 G094015X050-1 B0.5/B0.9 400/4 to 1200A 3.0 600:5 G096015S409-1 0.3 B1.8 C400 2.0 G096015X090-1 B0.9/B1.8 600/6 to 2400A 4.0 800:5 G098015S609-1 0.3 B1.8 C600 2.0 G098015X090-1 B0.9/B1.8 800/8 to 3200A 4.0 1000:5 G091025S809-1 0.3 B1.8 C800 2.0 G091025X180-1 B1.8 10 to 4000A 4.0 1200:5 G091225S809-1 0.3 B1.8 C800 2.0 G091225X180-1 B1.8 12 to 4800A 4.0 1500:5 G091525S809-1 0.3 B1.8 C800 2.0 G091525X180-1 B1.8 15 to 4500A 3.0 2000:5 G092025S809-1 0.3 B1.8 C800 2.0 G092025X180-1 B1.8 20 to 4000A 2.0 2500:5 G092525S809-1 0.3 B1.8 C800 2.0 -- -- -- -- 3000:5 G093025S809-1 0.3 B1.8 C800 1.5 -- -- -- -- 4000:5 G094025S809-1 0.3 B1.8 C800 1.5 -- -- -- -- 5000:5 G095025S809-1 0.3 B1.8 C800 1.5 -- -- -- -- 6000:5 G096025S809-1 0.3 B1.8 C800 1.5 -- -- -- -- 8000:5 G098025S809-1 0.3 B1.8 C800 1.25 -- -- -- -- 10000:5 G091035S809-1 0.3 B1.8 C800 1.0 -- -- -- -- 200/400:5 G092015D109-1 0.3 B0.5/B0.9 C100/C200 2.0/2.0 -- -- -- -- 300/600:5 G093015D209-1 0.3 B0.5/B1.8 C200/C400 2.0/2.0 -- -- -- -- 400/800:5 G094015D309-1 0.3 B0.9/B1.8 C300/C600 2.0/2.0 -- -- -- -- 600/1200:5 G096015D409-1 0.3 B1.8/B1.8 C400/C800 2.0/2.0 -- -- -- -- 1000/2000:5 G091025D409-1 0.3 B1.8/B1.8 C400/C800 2.0/2.0 -- -- -- -- 1500/3000:5 G091525D809-1 0.3 B1.8/B1.8 C800/C800 2.0/1.5 -- -- -- -- - Available in multi-ratio designs (full tap ratings same as single ratio above). - 1 Second Thermal/Mechanical : 80x full winding I nom / Unlimited mechanical. - Available with a primary bar kit (maximum 5500A). Change last digit of catalog from 1 to 3. 13

34500 Volt LG(X) 34 879 Current Transformer 14 NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS.

COF(CXM) 200 Current Transformer Outdoor 34.5kV, 200kV BIL, Single, Dual & Multi Ratios Oil-Filled, Wound Type, Metering/Relaying application The COF(CXM)-200 outdoor current transformer is rated for use on 34,500 volt systems with 200kV BIL. Primary current ratios are available from 5:5 to 3000:5 at 60 Hertz (Hz) with a of up to 4.0 (3200A max). This oil-fi lled current transformer will operate with high accuracy for metering or relay applications. 34500 Volt mechanical description The tank dome is fabricated from carbon or stainless steel, depending on current rating. The units are pressure and vacuum tight and hermetically sealed at the factory to prevent breathing and oil contamination. Tank components are washed and coated with anticorrosive iron phosphate and then fi nished with ANSI 70 Gray baked-on electrostatic polyester powder. The bushing is ANSI 70 Gray, high strength porcelain with a high degree of stability for transportation and seismic withstand. The primary terminals are tin plated aluminum, NEMA 4-hole pads for units rated 400A (copper for units rated 2000A) and NEMA 2-hole pads for units rated <400A. A bypass protector is provided for all units rated below 1200:5 to protect from transients. The secondary terminals are #10 slotted screws on a short circuiting terminal block located behind a removable cover in the CT base with three (3) 1 ½ NPT conduit hubs. The ground terminal is a stainless steel NEMA 2-hole pad. The unit is fi tted with a pressure relief valve, oil level gauge, and ½ drain valve. accuracy performance The COF-200 will operate with 0.3 Class accuracy for metering applications with burdens of B0.1 to B1.8. The unit can be designed with relay accuracy up to C800. The transformer is accurate through its, and can be used continuously to this level. The CXM-200 will operate with 0.15 Class high accuracy for metering applications with burdens of B0.1 to B1.8. The transformer maintains 0.15 Class accuracy from 0.5% of I nom through its, and can be used continuously to this level. ORDERING INFO FOR COF-200 Ratio Catalog Number* Accuracy/ mounting The COF(CXM) is designed for mounting on substations structures in an upright position with four mounting holes in the base. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Additional tests include dissipation and partial discharge tests. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 135% of the nominal system voltage. options The COF(CXM) is available with an Extra Creep Bushing, Polymer Bushing, Stainless Steel Tank, 4kV spark gap and/or -50 C oil. The unit can be offered in single, dual or multiple core designs. Contact factory for other needs. HIGH ACCURACY CXM-200 Catalog Number 0.15 B1.8 Acc Range 5:5 G950005SA 0.3 B1.8 1.5 G890005SA 0.025 to 20A 4.0 10:5 G950010SA 0.3 B1.8 1.5 G890010SA 0.05 to 40A 4.0 150:5 G950150SA 0.3 B1.8 1.5 G890150SA 0.75 to 600A 4.0 200:5 G950200SA 0.3 B1.8 1.5 G890200SA 1 to 800A 4.0 3000:5 G953000SA 0.3 B1.8 1.0 G893000SA 15 to 3200A 1.07 5/10:5 G950010DA 0.3 B1.8/B1.8 2.0/1.5 -- -- -- 10/20:5 G950020DA 0.3 B1.8/B1.8 2.0/1.5 -- -- -- -- -- -- 100/200:5 G950200DA 0.3 B1.8/B1.8 2.0/1.5 -- -- -- 150/300:5 G950300DA 0.3 B1.8/B1.8 2.0/1.5 -- -- -- -- -- -- 1000/2000:5 G952000DA 0.3 B1.8/B1.8 2.0/1.5 -- -- -- 1500/3000:5 G953000DA 0.3 B1.8/B1.8 2.0/1.0 -- -- -- - Available in multi-ratio designs (full tap ratings same as single ratio above). - 1 Second Thermal/Mechanical : Single Ratio (150x l nom ), Dual Ratio (75x full winding I nom ), 144kA max. * IC Approval AE-0600 Rev. 3 for 1200:5 MR. 15

34500 Volt COF(CXM) 200 Current Transformer 16 NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS.

JS(JXM) 200 1 Ø Metering Unit Outdoor 34.5kV, 200kV BIL, Single, Dual & Multi Ratios Oil-Filled, Wound Type, 1Ø Metering application The JS(JXM)-200 outdoor single phase metering unit is rated for use on 34,500 volt systems with 200kV BIL. Primary current ratios are 5:5 to 1200:5 at 60 Hertz (Hz) with a of up to 4.0 (1200A max). Primary voltage ratios are available from 140:1 to 300:1 for use on 34,500 volt, Grd Y systems. This oilfi lled metering unit will operate with high accuracy for metering applications. mechanical description The tank is a standard distribution transformer tank made of heavy gauge sheet steel with a seam welded bottom plate and a dome shaped cover. The tank is washed and coated with anticorrosive iron phosphate and then fi nished with an ANSI 70 Gray bakedon electrostatic polyester powder. The primary bushings are ANSI 70 Gray, high strength porcelain with a tin plated bronze, NEMA 1-hole primary terminal. NEMA 4-hole primary terminals are provided for units rated above 200A. A bypass protector is provided for all units rated below 1200:5 to protect from transients. A 5kV H 0 Bushing is included for power factor measurements and is connected to the tank ground, a tin plated bronze eyebolt. The secondary terminals consist of a feed thru block with ¼ -20 copper studs and associated hardware located inside a removable terminal box with three (3) 1 ½ NPT conduit hubs. The unit also includes a pressure relief valve. accuracy performance The JS-200 will operate, for the current transformer, with 0.3 Class accuracy for metering with burdens of B0.1 to B1.8. The CT is accurate through its, and can be used continuously to this level. The unit will operate, for the voltage transformer, with 0.3 Class accuracy for metering with burdens of 0, W, X, M, Y, Z and ZZ. The VT is accurate from 90% to 110% of rated primary voltage. The JXM-200 will operate, for the current transformer, with 0.15 Class accuracy for metering with burdens of B0.1 to B1.8. The CT maintains 0.15 Class accuracy from 0.5% of I nom through its, and can be used continuously to this level. The unit will operate, for the voltage transformer, with 0.15 Class accuracy for metering with burdens of 0, W, X, M, Y and Z, as well as 0.3 ZZ. The VT is accurate from 90% to 110% of rated primary voltage. mounting The JS(JXM) is designed for mounting on poles or substation structures in an upright position with ANSI type A hanger brackets or optional mounting feet. NOTE: Must be installed per NESC electrical clearances. 34500 Volt testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Additional tests include dissipation and partial discharge tests. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 135% of the nominal system voltage. options The JS(JXM) is available with Lighting Arrestors, NEMA 4-hole Primary Terminals, NEMA 2-hole Ground Pad, Mounting Feet, Stainless Steel Tank, 4kV Spark Gap, Oil Level Indicator, Oil Drain Valve, and/or -50 C oil. Contact factory for other needs. ORDERING INFO FOR JS-200 HIGH ACCURACY JXM-200 Voltage Ratio* - 175:1 Accuracy/ Accuracy/ s Pri*:Sec - 20125:115 0.3 0,W,X,M,Y,Z,ZZ 0.15 0,W,X,M,Y,Z, 0.3 ZZ Current Ratio Catalog Number Accuracy/ Catalog Number 0.15 B1.8 Acc Range 10:5 G80001S17EA 0.3 B1.8 1.5 G79001S17EA 0.05 to 40A 4.0 20:5 G80002S17EA 0.3 B1.8 1.5 G79002S17EA 0.1 to 80A 4.0 150:5 G80015S17EA 0.3 B1.8 1.5 G79015S17EA 0.75 to 600A 4.0 200:5 G80020S17EA 0.3 B1.8 1.5 G79020S17EA 1 to 800A 4.0 1000:5 G80100S17EA 0.3 B1.8 1.2 G79100S17EA 5 to 1200A 1.2 1200:5 G80120S17EA 0.3 B1.8 1.0 G79120S17EA 6 to 1200A 1.0 5/10:5 G80001D17EA 0.3 B1.8/B1.8 2.0/1.5 -- -- -- 10/20:5 G80002D17EA 0.3 B1.8/B1.8 2.0/1.5 -- -- -- -- -- -- 500/1000:5 G80100D17EA 0.3 B1.8/B1.8 2.0/1.2 -- -- -- 600/1200:5 G80120D17EA 0.3 B1.8/B1.8 2.0/1.0 -- -- -- - Available in multi-ratio designs. - Thermal (Typical): 4000VA. - Overvoltage : 1.1x cont., 1.9x 8 hours. - 1 Second Thermal/Mechanical : Single Ratio (150x l nom ), Dual Ratio (75x full winding I nom ), 144kA max. * Other Primary Voltage s Available, contact factory. 19

34500 Volt JS(JXM) 200 1 Ø Metering Unit 20 NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS.

MVCT(MXM) 200 3 Ø Metering Unit Outdoor 34.5kV, 200kV BIL, Single, Dual & Multi Ratios Oil-Filled, Wound Type, 3Ø Metering application The MVCT(MXM)-200 outdoor three phase metering unit is rated for use on 34,5000 volt systems with 200kV BIL. Primary current ratios are 5:5 to 1200:5 for 60 Hertz (Hz) with a of up to 4.0 (1200A max). Primary voltage ratios are available from 140:1 to 520:1 for use on 34,500 volt systems. This oilfi lled metering unit will operate with high accuracy for 2, 2 ½ or 3 element metering applications. mechanical description The unit is built of heavy walled steel construction similar to proven distribution and small power transformer construction and is strongly braced to withstand both electrical and mechanical stresses. The tank is washed and coated with anticorrosive iron phosphate and then fi nished with an ANSI 70 Gray baked-on electrostatic polyester powder. The primary bushings are ANSI 70 Gray, high strength porcelain with tin plated bronze, NEMA 4-hole primary terminals. The secondary terminals consist of a feed thru block with ¼ -20 copper studs and associated hardware located inside a terminal box with three (3) 1 ½ NPT conduit hubs. The ground terminal is a stainless steel NEMA 2-hole pad. The unit includes a pressure relief valve, CT by-pass protectors, 5kV H 0 Bushing (for 3P 4W designs), ½ oil drain valve, and a magnetic type oil level gauge which is easily read from a distance. accuracy performance The MVCT-200 will operate, for the current transformers, with 0.3 Class accuracy for metering with burdens of B0.1 to B1.8. The CT s are accurate through their, and can be used continuously to this level. The unit will operate, for the voltage transformers, with 0.3 Class accuracy for metering with burdens of 0, W, X, M, Y, Z and ZZ. The VT s are accurate from 90% to 110% of rated primary voltage. The MXM-200 will operate, for the current transformers, with 0.15 Class high accuracy for metering applications with burdens of B0.1 to B1.8. The transformer maintains 0.15 Class accuracy from 0.5% of I nom through its, and can be used continuously to this level. The unit will operate, for the voltage transformers, with 0.15 Class accuracy for metering with burdens of 0, W, X, M, Y and Z, as well as 0.3 ZZ. The VT s are accurate from 90% to 110% of rated primary voltage. 34500 Volt mounting The MVCT(MXM) is designed for overhead mounting on poles or substation structures in an upright position with ANSI type C hanger brackets or four mounting holes in the base. NOTE: Must be installed per NESC electrical clearances. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Additional tests include dissipation and partial discharge tests. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 135% of the nominal system voltage. options The MVCT(MXM) is available with a Stainless Steel Tank, 4kV Spark Gaps and/or -50 C oil. Contact factory for other needs. ORDERING INFO FOR MVCT-200 HIGH ACCURACY MXM-200 Voltage Ratio* - 175:1 Accuracy/ Accuracy/ s Pri*:Sec - 20125:115 0.3 0,W,X,M,Y,Z,ZZ 0.15 0,W,X,M,Y,Z, 0.3 ZZ Current Ratio Catalog Number (3P 4W)** Accuracy/ Catalog Number (3P 4W) 0.15 B1.8 Acc Range 10:5 G88001S17CA 0.3 B1.8 1.5 G86001S17CA 0.05 to 40A 4.0 20:5 G88002S17CA 0.3 B1.8 1.5 G86002S17CA 0.1 to 80A 4.0 150:5 G88015S17CA 0.3 B1.8 1.5 G86015S17CA 0.75 to 600A 4.0 200:5 G88020S17CA 0.3 B1.8 1.5 G86020S17CA 1 to 800A 4.0 1000:5 G88100S17CA 0.3 B1.8 1.2 G86100S17CA 5 to 1200A 1.2 1200:5 G88120S17CA 0.3 B1.8 1.0 G86120S17CA 6 to 1200A 1.0 5/10:5 G88001D17CA 0.3 B1.8/B1.8 2.0/1.5 -- -- -- 10/20:5 G88002D17CA 0.3 B1.8/B1.8 2.0/1.5 -- -- -- -- -- -- 500/1000:5 G88100D17CA 0.3 B1.8/B1.8 2.0/1.2 -- -- -- 600/1200:5 G88120D17CA 0.3 B1.8/B1.8 2.0/1.0 -- -- -- - Available in multi-ratio designs. - Thermal (Typical): 6000VA (2000VA/phase). - Overvoltage : 1.1x cont., 1.9x 8 hours (3P 4W). - 1 Second Thermal/Mechanical : Single Ratio (150x l nom ), Dual Ratio (75x full winding I nom ), 144kA max. * Other Primary Voltage s Available, contact factory. ** For 3P 3W, change catalog digits 88 to 87. 21

34500 Volt MVCT(MXM) 200 3 Ø Metering Unit 22 NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS.