OHIO MODEL RD-2A AUTO/MANUAL DROP MAGNET CONTROLLER INSTALLATION, MAINTENANCE, AND PARTS BULLETIN

Similar documents
OHIO MODELCDS AUTO/MANUAL DROP MAGNET CONTROLLER DESCRIPTION INSTALLATION PROCEDURES INSTALLATION, MAINTENANCE, AND PARTS BULLETIN

SERVICE AND REPAIR PARTS NEMA SIZE 5, SINGLE POLE, NORMALLY CLOSED, P/N SERIES NEMA SIZE 5A, SINGLE POLE, NORMALLY CLOSED, P/N SERIES

SERVICE AND REPAIR PARTS NEMA SIZE 3, SINGLE POLE, NORMALLY OPEN, P/N SERIES NEMA SIZE 4, SINGLE POLE, NORMALLY OPEN, P/N SERIES

SERVICE AND REPAIR PARTS NEMA SIZE 5, SINGLE POLE, NORMALLY OPEN, P/N SERIES NEMA SIZE 5A, SINGLE POLE, NORMALLY OPEN, P/N SERIES

Euclid Full Voltage Magnet Controller

OHIO MODEL MC-1A AUTO/MANUAL DROP MAGNET CONTROLLER

Syntron EB-00 Vibratory Parts Feeder GENERAL MANUAL

Service Instructions. Syntron Light-Capacity Electromagnetic Model: F-T01-A DF-T01-A

DESCRIPTION OHIO MODEL MC-1A AUTO / MANUAL DROP MAGNET CONTROLLER INSTALLATION PROCEDURES INSTALLATION, MAINTENANCE, AND PARTS BULLETIN

OHIO MODEL RD-1W AUTO / MANUAL DROP MAGNET CONTROLLER

4.0 OPERATION Type ITH-T Relay

Service Instructions. Syntron TJ-2-B Jogger

Service Instructions. Syntron Electromagnetic Feeder Model: F-010-B DF-010-B

WESTERN-CULLEN-HAYES, INC.

NOTE: Local safety codes and regulations must be considered when installing and/or operating this unit.

DRUM BRAKE ADJUSTMENTS, MODELS #90, #100, #110 & #120 # BRAKE MONITOR

Service Instructions. Syntron Jogger Model: J-1-B

Section 6 Exploded Views and Parts Lists. 42 Generac Power Systems, Inc.

Crane Control. Crane Control 1. Contents. Description Heavy-Duty Brakes Shoe Brakes Magnetically Operated Master and Limit Switch Family

Technical Service Parts Breakdown

80 Series 4 Post Brake Instructions

C.E. Niehoff & Co. C703/C703A and C706 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

MODEL D ELECTRIC TWO-STAGE HYDRAULIC PUMP

DIRECT DRIVE CONCRETE TROWELS F30, F36, & F46 PARTS MANUAL MASTER EQUIPMENT MASTER EQUIPMENT

Spare Parts List. EW-3500-C and D EW-4200-C and D Marine Diesel Generators

Service Instructions. V-9-D Vibrator

Heavy Duty DC Battery Disconnecting Switches

Section 7 Exploded Views and Parts Lists. 40 Generac Power Systems, Inc.

Lincolnweld AC-1000 POWER SOURCE

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

CD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK

C802/C802D/C802TD/C820 Alternators Troubleshooting Guide

Instruction Sheet. 7 x 22 (178 x 559 mm) Rear Roller Brush Product No WARNING Rev A

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK

Service Instructions. Syntron Vibrating Feeder Model: F-010-BM

C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING

Model 5-025, 5-050, &

Service Instructions. Syntron Electromagnetic Vibratory Feeder Model: F-212-B

Control Relays Overview

CR193 Vacuum Limitamp* Contactors

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION

Parts Catalog SLICING MACHINES

Section 7 Exploded Views and Parts Lists IMPACT-36 plus II Recreational Vehicle Generator Control Panel Drawing No. 0E7560

EXPLODED VIEW BASE AND PULLEYS Drawing No

Illustrated Parts List for GPU-400

Operations & Maintenance Manual and Parts Bulletin

Guardmatic Masonry / Refractory Saw Gasoline Model Parts List

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

ALTERNATOR - BOSCH 35/75-AMP & 40/90-AMP

Parts Catalog. S-Series Slicer Automatic. Model:

PRIME 3-BURNER PROPANE BARBECUE Assembly Manual

Parts Catalog. S-Series Slicer Standard Automatic Frozen Option S13A. Model:

Model 10 Crossing Signal

Thermal. Dimensions Torque Rotating. Rotating Capacity lb.ft. HPS/Min. Lb-Ft

Automotive Parts. Charging & Starting Systems

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS

Series 20 Installation Instructions

INSTALLATION AND PARTS MANUAL

REV: 000. Super Seca Flash Cure Units

C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

PARTS LIST FOR RED-D-ARC DC-400 DC-400

Syntron F-450-C Electromagnetic Vibratory Feeder

ELECTRICAL. CDTA Technical Training Center

Parts Catalog. S-Series Slicer Standard Automatic S13A. Model:

DIRACT BRAKES 70 SERIES 4 POST BRAKE INSTRUCTIONS

Lumina 20 Brush Drive Battery Burnisher Parts and Instruction Manual

THE BATTERY CHARGER OF RON PUGH

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

Mig 5000i, Mig U5000i 400 V version. Spare parts list. Edition Valid for serial no. 803 xxx xxxx,

Yaskawa Electric America Unit Troubleshooting Manual Section One: Introduction & Checks Without Power GPD 506/P5 and GPD 515/G5 (0.

ELITE 2-BURNER PROPANE BARBECUE Assembly Manual

C627, C628, C631, C656, C657, C658, C671 and C680 Alternator Troubleshooting Guide

C.E. Niehoff & Co. C840D Alternator Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

Electronic Service Manuals

B CW POWER RELAY

SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP)

XENON POWER SUPPLY 4000 Watt Gladiator IV

MINE CHARGER INSTALLATION AND OPERATION MANUAL MODEL NUMBERS: MSP MSQ MSR MSS

IPL MODEL SWZV ILLUSTRATED PARTS LIST. with a serial number of E to E THIS MANUAL CONTAINS THE ILLUSTRATED PARTS LIST FOR MODELS:

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AC Contactors. Type IC5181. Ward Leonard Electric Company Inc. 401 Watertown Road Thomaston, CT USA Tel:

SELECT 3-BURNER PROPANE BARBECUE Assembly Manual

Issue/Rev. 0.3 (2/04) Bulletin P

Installation of Hydraulic Kit STD Controls w/ standard pump/manifold location

Installation Sheet January, 2016 Supersedes February, 2013

This Kit Is for Use with Types RE, RVE, WE, WVE, VWE, VWVE27, and VWVE38 Reclosers.

ALTERNATOR - CHRYSLER 40/90-AMP & 50/120 AMP

TYPE KF UNDER-FREQUENCY RELAY A. Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) Front View Rear View

Cross Reference Listing of Caterpillar parts to Kress parts for Kress 200C II Coal Haulers (Serial Numbers HND-M096, HND-M097, & HND-M098)

ILLUSTRATED PARTS LIST MODEL NO CUSTOMER CATALOG NO. MOWCART 66 PRODUCT NO Rev 2

CHEVROLET/GMC K10 - K20 - K BLAZER/JIMMY/SUBURBAN/CREWCAB CAB CHASSIS 4X ATTACHMENT KIT

MCS-203 Dancer Control

RZT TWIN STICK HYDRO DRIVE 250 Z 44" & 50" SERIES 0

Parts Catalog. S-Series Slicer Standard Automatic S13A. Model:

Section 6 Exploded Views and Parts Lists IMPACT-36 plus II Recreational Vehicle Generator Control Panel Drawing No. 0E7560

TS-E TURBO STEAM ELECTRIC COUNTERTOP CONVECTION STEAMER PARTS AND SERVICE MANUAL

Service Instructions. Syntron Electromagnetic Feeder Model:BF-4-ALF and BF-4-ASLF (stainless steel hardware)

VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines

XENON POWER SUPPLY Watt

Transcription:

OHIO MODEL RD-2A AUTO/MANUAL DROP CONTROLLER INSTALLATION, MAINTENANCE, AND PARTS BULLETIN OPERATING RANGE 100-150 A (COLD CURRENT) DESCRIPTION The RD-2A Controller is a heavy duty magnet controller used for magnets whose cold current ranges from 100 A to 150 A dc. Cold current references the current flowing through the magnet when the magnet temperature is 25 C throughout. AUTOMATIC DROP A reverse current adjustment provides for a fast, clean drop of the magnet over a complete range of magnetic material with one movement of the master switch or push button. MANUAL DROP Allows for partial dropping of the load by controlling the amount of reverse current to the magnet. A drop position on the master switch or a push button that is spring returned to off, gives the operator complete control of the drop cycle. INSTALLATION PROCEDURES Mount the controller to a solid surface with the mounting bars provided. The controller must be mounted vertically with the TOP up to operate properly. Mount the controller away from sources of heat and direct exhaust of engines. Allow enough room around the controller for air circulation. Route electrical wires through bottom of the enclosure and connect securely to the terminals. All electrical circuits must be free from grounds and shorts. Remove shipping material from the arc shields before operating the controller. Adjust the reverse current control rheostat to provide enough reverse current to cleanly drop the magnet load. Procedure Start with the dial set at low range. Pick up and drop a load of the material to be handled. If the material does not completely fall off the magnet, increase the adjustment and try another load. If the material drops off and then some jumps back up to the magnet before it can fall free, reduce the adjustment and try another load. When all the material falls cleanly from the magnet, the controller is properly set.

RD-2A SUBASSEMBLIES 018B0217A 27 018B5074X 31 33 018C0216X 28 018B1478X 018D3090B 35 29 018B2966V

OHIO MODEL RD-2A AUTO/MANUAL DROP CONTROLLER RD-2A CONTROLLER EXPLODED ASSEMBLY VIEW NOTES: WIRE KIT: WIREKIT-RD2A RD-2A AUTOMATIC Controller Shown Complete Resistor Assembly: 018A8101A NOT SHOWN 018A8101G 7 Req d Resistor 3.2 Ohms 018A8101E 2 Req d Connector 018A8101F 5 Req d Terminals 018A8101D 3 Req d Connector 018A8101C 28 Req d Mica Washers

RD-2A HARDWARE SPECIFICATIONS LIST ITEM PART NUMBER QTY. DESCRIPTION MAT L 44 A-900007-02 4 SCR HX HD 5/16-18 UNC x 3/4" STEEL 46 A-900007-05 4 SCR HX HD 5/16-18 UNC x 1-1/4" STEEL 47 A-900007-06 5 SCR HX HD 5/16-18 UNC x 1-1/2" STEEL 49 A-900007-08 1 SCR HX HD 5/16-18 UNC x 2" STEEL 50 A-900008-08 1 SCR HX HD 3/8-16 UNC x 1-3/4" STEEL 51 A-900010-09 1 SCR HX HD 1/2-13 UNC x 2-1/2" STEEL 52 A-900416-05 3 SCR RH SLTD M4 x 0.7 x 10 mm STEEL 55 A-900023-07 2 SCR RH SLTD #10-32 UNF x 7/8" STEEL 56 A-900023-09 7 SCR RH SLTD #10-32 UNF x 1-1/4" STEEL 59 A-900023-14 10 SCR RH SLTD #10-32 UNF x 3/8" BRASS 60 A-900023-15 2 SCR RH SLTD #10-32 UNF x 1/2" BRASS 62 A-900023-25 2 SCR RH SLTD #10-32 UNF x 1-3/4" BRASS 63 A-900023-28 1 SCR RH SLTD #10-32 UNF x 1-3/8" STEEL 64 A-900025-16 2 SCR RH SLTD 1/4-20 UNC x 3/8" BRASS 65 A-900025-17 4 SCR RH SLTD 1/4-20 UNC x 1/2" BRASS 67 A-900025-22 4 SCR RH SLTD 1/4-20 UNC x 1-3/4" BRASS 68 A-900061-02 1 SCR SET HX SOC CP PT #10-32 x 1/4" STEEL 70 A-900106-38 3 NUT HX M4 x 0.7 mm STEEL 71 A-900106-03 5 NUT HX #10-32 UNF STEEL 72 A-900106-05 8 NUT HX 1/4-20 UNC STEEL 74 A-900108-11 2 NUT HX JAM 1/4-20 UNC BRASS 75 A-900108-12 4 NUT HX JAM 5/16-18 UNC BRASS 76 A-900172-07 20 NUT HX JAM 3/8-16 UNC BRASS 77 A-900115-28 5 M4 SPLIT LOCKWASHER STEEL 78 A-900115-03 25 #10 SPLIT LOCKWASHER STEEL 79 A-900115-05 22 1/4" SPLIT LOCKWASHER STEEL 80 A-900115-06 19 5/16" SPLIT LOCKWASHER STEEL 81 A-900115-07 10 3/8" SPLIT LOCKWASHER STEEL 82 A-900115-09 1 1/2" SPLIT LOCKWASHER STEEL 83 A-900118-03 11 #10 FLATWASHER STEEL 84 A-900118-05 14 1/4" FLATWASHER STEEL 85 A-900118-06 8 5/16" FLATWASHER STEEL 86 A-900118-07 10 3/8" FLATWASHER STEEL 87 A-900118-09 3 1/2" FLATWASHER STEEL 88 A-900118-18 10 #10 FLATWASHER BRASS 89 A-900118-20 2 1/4" FLATWASHER BRASS 90 A-900021-23 2 SCR RD SLTD #8-32 UNF x 3/4" BRASS 91 A-900219-02 2 EXT. RET. RING 1/4" SHAFT STEEL 94 A-900219-09 2 EXT. RET. RING 1/2" SHAFT STEEL 96 A-900118-21 4 3/8" FLATWASHER BRASS 97 A-900023-12 2 SCR RD SLTD #10-32 UNF x 1/4" BRASS 98 A-900118-27 2 #10 FLATWASHER BRASS 99 A-900115-18 2 #10 SPLIT LOCKWASHER BRASS ITEM PART NUMBER REQ. DESCRIPTION Man/Auto 1 A-900118-21 4 3/8" FLATWASHER 2 A-900215-02 4 CABLE CONNECTOR (#2-#8) 3 A-900228-01A 0/1 RHEOSTAT DIAL 4 A-900229-02 0/1 RHEOSTAT MNTG. KIT. 5 A-900232-04 0/1 RHEOSTAT 0.5-150 W 6 A-900233-02 0/1 RHEOSTAT KNOB 7 018A0123X 2 BLOWOUT BLT. W/STUD 8 018A0124X 2 BLOWOUT BLT. 9 018A0140C 1 ARM PIN 1/2" DIA. (Ø12 mm) 10 018A0151F 1 MAIN COIL 230 V 11 018A0152X 2 INSULATING WASHER 12 018A0154A 1 CORE ASSEMBLY 13 018A0317D 2 SHUNT ASSEMBLY 14 018A2615X 1 SWITCH FRAME 15 018A2622X 1 SWITCH ARM ASSEMBLY 16 018A2623A 1 ARM PIN 1/4" DIA. (Ø6 mm) 17 018A2637X 1 SPRING WASHER 18 018A2720X 2 SHUNT ASSEMBLY 19 018A2866X 1 CLAMP WASHER 20 018A2977X 2 SEPARATOR WASHER 21 018A3010X 8/10 TERMINAL STUD 22 018A3075X 0/1 REVERSE SWITCH CORE 22a 018A6209A 1/0 REVERSE CORE ASSEMBLY 23 018A3878A 4 TERMINAL STUD 2-1/2" (65 mm) 24 018A3878X 2 TERMINAL STUD 2-3/4" (70 mm) 25 018A3882X 3/2 TERMINAL STUD 26 018B0116X 1 MAIN FRAME 27 018B0217A 2 BLOWOUT COIL ASSEMBLY 27a 018A0125X 2 CONTACT TIP 28 018B1478X 2 BLOWOUT COIL ASSEMBLY 28a 018A0803X 4 ARC SHIELD SIDE 28b 018A1443X 2 CONTACT TIP 28c 018A1503X 2 ARC SHIELD SPACER 28d 018A1523X 2 DOWEL 28e 018B2727X 2 BLOWOUT COIL ASSEMBLY 29 018B2966V 1 DIODE ASSEMBLY 29a A-900565-18 1 HEAT SINK DRILLED 29b A-900550-26 1 DIODE MODULE 29c 018A2966Q 2 MOV SUPPRESSOR ASSEMBLY 30 018A2966Z 1 CONTROL DIODE 31 018B5074X 1 SWITCH ARM ASSEMBLY 31a 018A1443X 2 CONTACT TIP 31b 018A2604A 1 CONTACT BRACKET 31c 018A2605A 1 CONTACT BRACKET 31d 018A2614A 2 CONTACT ARM ASSEMBLY 31e 018A2614X 2 CONTACT ARM 31f 018A2618X 1 REVERSE ARM SHAFT 31g 018A2625X 2 CONTACT SPRING 31h 018A2631X 2 SPACER WASHER 32 018A1508A 1/0 REVERSE SWITCH COIL 36 V 32a 018B6156X 0/1 DROP COIL 33 018C0216X 2 ARC SHIELD ASSEMBLY 33a 018A0120X 4 BLOWOUT EAR 33b 018A0126X 2 SPACER 33c 018A0130X 4 BLOWOUT SHIELD 33d 018A0139X 4 STUD 3-1/8" (80 mm) 33e 018A1362X 16 WASHER 34 018C5184X 1 PANEL 35 018D3090B 1 MAIN ARM ASSEMBLY 35a A-900221-05 2 HAIR PIN CLIP Ø3/8" (Ø10 mm) SHAFT 35b 018A0104X 1 SPRING LEFT 35c 018A0118X 2 CONTACT ARM MACHINED 35d 018A0121X 1 SPRING RIGHT 35e 018A0125X 2 CONTACT TIP 35f 018A0128A 2 ARM INSULATION 35g 018A0129X 2 STOP WASHER 35h 018A0135X 2 SPRING PIN 35k 018A0138X 1 STOP 35p A-900298-02 2 BEARING SELF LUBRICATING 35q 018A5645X 1 THREADED ROD 35s 018B0219A 2 CONTACT ARM ASSEMBLY 35t 018C2992A 1 MAIN ARM MACH. 35u A-900298-03 2 BEARING SELF LUBRICATING

RD-2A WIRING DIAGRAM RD-2A AUTOMATIC CONTROLLER WIRE DIAGRAM P/N: 018B6155V RD-2A MANUAL CONTROLLER WIRE DIAGRAM P/N: 018B6155AA RESISTOR ASSEMBLY RESISTOR ASSEMBLY PANEL REAR VIEW PANEL REAR VIEW SCHEMATIC DIAGRAM SCHEMATIC DIAGRAM CONTROLLER CONTROLLER MASTER SWITCH MASTER SWITCH WIRING DIAGRAM WIRING DIAGRAM SYSTEMS DIAGRAM SYSTEMS DIAGRAM TABLE OF EQUIPMENT SYMBOL DESCRIPTION FUNCTION D REVERSE CONTACTOR DROP L MAIN CONTACTOR LIFT R1 3.2 RESISTORS DROP RESISTOR R2 3.2 RESISTORS DROP RESISTOR R3 3.2 RESISTORS DISCHARGE RESISTOR RHEO. 0.5 RHEOSTAT DROP ADJUSTMENT DM1 DIODE BLOCKING DIODE Z1-Z2 MOV SUPPRESSOR DIODE PROTECTION CR CONTROL RECTIFIER ANTI-REVERSE PROTECTION STEP BY STEP CONTROLLER OPERATION AUTOMATIC CONTROLLER 1. When a lift signal is given by closing the contacts between terminals F and U, the L coil is energized. 2. This closes the L contacts which supplies full power to the magnet. 3. When a drop signal is given the F to U contact is broken and the L coil is de-energized. 4. This opens the L contacts and at the same time allowing current to flow through blocking diode DM1. 5. A discharge circuit is set up through resistors R3 and the 4, 2 winding of the D coil, (energizing the coil). 6. This causes the energy in the magnet to be dissipated to the R3 resistor, and the D contacts to close. 7. Reverse voltage is then applied to the magnet through the R1 and R2 resistors. 8. When the proper amount of reverse current to the magnet, (as adjusted by the rheostat), is measured by the 4, 2 winding of the D coil, it cancels the affect of the 1, 3 winding of the D coil and the D contacts open. 9. This stops the flow of reverse current through the magnet.

STEP BY STEP CONTROLLER OPERATION MANUAL CONTROLLER 1. When a lift signal is given by closing the contacts between terminals F and U, the L coil is energized. 2. This closes the L contacts which supplies full power to the magnet. 3. When a drop signal is given the F to U contact is broken and the L coil is de-energized. 4. This opens the L contacts and allows current to flow through blocking diode DM1. 5. A discharge circuit is set up through resistor R3. 6. Energy in the magnet is dissipated to the R3 resistor. 7. Moving the master switch to the drop position or pushing the drop button, closes the contact between terminals F and D, energizing the D coil. 8. This closes the D contacts and provides reverse voltage to the magnet, through resistors R1 and R2. 9. To stop the build up of reverse current, release the master switch control and it will return to the off position, or release the drop push button. 10. This breaks the contact between the F and D terminals, de-energizes the D coil, (opening the D contacts), and stops the flow of reverse current through the magnet. MAINTENANCE AND TROUBLE SHOOTING Check all contact tips for excess wear or burning. Replace if needed. Check arc shields for burnt areas. Replace any that are badly burned. Check for burned or damaged insulation on shunts or wires. Replace if found. Check for carbon tracking on the base panel and insulating parts. If found, remove by filing or scraping. If carbon can not be removed, replace the part. Check gap ( 3 4" (20 mm) opening) between main contacts (#27a and #35e). Adjust by loosening screw (#46) on part (#35c) and turning the assembly. All pin connections should move easily, and contact springs should provide force when contacts are closed. If springs do not provide contact force, replace them. Check Power Diode Integrity (DM1) with a standard Digital Volt Meter (DVM), set to the diode check function. (See owner s manual for details.) Disconnect leads to the diode and remove suppressors MOV (Z1 and Z2) to isolate from the circuit. Place the red lead of meter on Terminal 1 of diode (number is stamped next to terminal) and the black lead on Terminal 2. Meter should read <1.0. Reverse leads and meter should read 1.(00). Repeat for Terminals 3 (red) and 1 (black). If the diode reads bad, replace. Reconnect wires and MOVS (Z1 and Z2). NOTE: Z1 and Z2 are MOV suppressors to help limit voltage spikes applied to DM1 and causing damage. EMERGENCY SPARE PARTS KITS AND /OR KITS Automatic #ESP-018M5154TI Contains the parts most likely to fail due to a system problem or a high voltage spike. It is recommended that one of these kits be kept on hand to avoid unnecessary down time. Conversion Kit #018M2966W Converts old style contact arm to diode. OHIO ICS PERFORMANCE ENGINEERED OHIO ICS, INC. SUBSIDIARY OF PEERLESS-WINSMITH, INC. 5400 DUNHAM ROAD, MAPLE HEIGHTS, OH 44137-3687 800/486-6446 216/662-8484 FAX: 216/662-9526 216/662-2911 216/662-3118 E-mail: salesohiomag1@qwest.net engohiomag1@qwest.net Web sites: ohiomagnetics.com stearnsmagnetics.com Sales Company Engineering OM-19235 November 2002 Printed in U.S.A.