Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Similar documents
Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

DHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W

Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification ATEX, IECEx, EAC or CULUS certification

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

Solenoid directional valves type DHAL8 and DHWL8 direct operated, ISO 4401 size 06, ex-proof or intrinsically safe, low leakage execution

Ex-proof ISO cartridge valves multicertification ATEX, IECEx, EAC or North American certification CULUS directional control, ISO 7368

Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - ATEX or IECEx certification

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06

Pressure control valves type AGIR, AGIS, AGIU two stage, subplate mounting, ISO 5781 sizes 10, 20 and 32

Pressure relief valves type ARAM

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES

SOLENOID DIRECTIONAL VALVE

Solenoid directional valves type DPHI and DPHE two stage, ISO 4401 size 10, 16, 25 and 32

Proportional reducing valves

Proportional relief valves

Proportional pressure reducing cartridges type LIRCZO normally closed, ISO 7368 sizes from 16 to 40

INSTRUCTION MANUAL (ATEX / IECEx)

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

INSTRUCTION MANUAL (ATEX / IECEx)

VSD*HL-*-KD2 - HAZARDOUS LOCATION, SOLENOID, DIRECT & PILOT OPERATED VALVES

ISO cartridge valves type LIM*, LIRA, LIC*

Proportional reducing valves

ISO cartridge valves type LIDD and LIQV Flow control, ISO 7368 sizes 16 63

VALIADIS S.A. HELLENIC MOTORS

Proportional reducing valves

ISO cartridge valves type LIDEW* and LIDBH*

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

Proportional relief valves with integral pressure transducer

Q max (see specifications table)

ADVANTAGES. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

Proportional reducing valves with integral pressure transducer

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

2/2 Solenoid Cartridge Valve, Size 6

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

Ex m Solenoid Operator Type 0519

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Terminal Boxes Series 8125

Safety cartridge valves with poppet position monitoring

Complementary safety valves with /FC mechanical microswitches conforming to Machine Directive 2006/42/CE

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Proportional relief valves with integral pressure transducer

High Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"

Proportional flow valves

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 5X CENELEC STANDARD & ATEX DIRECTIVE

CCAI, CCAIF, CCAIF..H

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Solenoid coils VACF Type codes

Chapter 2: Directional Control Valves

General Specifications DRV DRV-Exm DRV-Exd

Directional spool valves, direct operated, with solenoid actuation. Type WE. Contents. Features. RE Edition: Replaces:

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

Proportional directional valves type DHZO-AES and DKZOR-AES direct operated, without position transducer, ISO 4401 size 06 and 10

Load disconnect switch Series 8146/5-V11

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Proportional relief valves with integral pressure transducer

Type Z & Ex pz purge and pressurization system

Directional Control Valve Series D1VW

Explosion and flame-proof cast iron electric motors

High voltage flameproof induction motors The simplest solution for hazardous environments

Directional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents. RE Edition: Replaces:

Ex-proof proportional valves multicertification ATEX, IECEx, EAC

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES

YFC. Limit switch. Ex d. 24 operating head types

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

3/2 and 4/2 directional seat valves with solenoid actuation

Modular Explosion Proof Brakes. IECLine rev 0

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

Operating Instructions

HERION SERIES Indirect solenoid actuated soft seal

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4

Explosion protected hydraulic products. Product overview industrial and mobile hydraulics

Proportional Solenoid for Hydraulics ATEX + IECEX

Sentronic PLUS 614 Series

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Solenoid directional valves type DPHI, DPHU

Terminal Boxes Series 8125

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min

ExBin-P Pressure switches 5 Pa Pa

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

M-0. M-0... series control, monitoring and signalling devices. Ex e

Explosion and flame-proof single phase electric motors

Solenoid directional valves Pmax 420 bar direct operated, ISO 4401 size 06 and size 10

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

Safety directional valves with spool position monitoring

Assembly. Trunk IN + - S U, I U, I. Spur 1

Safety valves direct, pilot operated and cartridge execution

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Zone 1 Linear Range - Installation Guide

Pneumatic control unit for decentralized automation of ELEMENT process valves

Transcription:

www.atos.com Table TF040-2/E Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 A B DHRZO-A-012/25 A B DHRZA-A-010/25 DHRZ* are 3 way, proportional pressure reducing valves, direct operated, with standard ISO 4401 size 06 mounting surface Technical characteristics They provide the pressure reduction on ports A, or B or A and B, depending on the valve model. The direct execution performs low internal leakages, fast response and low hysteresis. The valves are available in different executions: - standard proportional solenoids with separated (-A) or integral (-AE) electronics - ex-proof solenoids certified : Multicertifications for solenoids group II for surface plants with gas, vapours and dust environment ATEX 94/9/EC Ex II 2 GD Ex d IIC T6/T4 Ex td A21 IP67 - category 2, zone 1, 2, 21 & 22 IECEx worldwide recognized safety certification, Ex d IIC T6/T4, Ex td A21 IP67 Rostechnadzor Russian Certification Ex d IIC T6/T4 Multicertifications for solenoids group I for surface, tunnels or mining plants ATEX 94/9/EC: Ex I M2 Ex d I Mb IECEx: EX d I Mb CULUS UL1002 and CSA 22.2 n 139-1982 Standard, Class I, Groups C&D (Groups IIA & IIB to NEC 505-7) Typical applications Pressure reduction in low flow systems Pilot stage for proportional valves DPZO-A* and QVMZO-A* 1 MODEL CODE DHRZA - A - 010 / 25 / PA - GK / O /* ** /PE Proportional pressure reducing valve DHRZO = standard version Ex-proof, Multicertification ATEX, IECEx, Rost DHRZA = Group II DHRZA/M = Group I (Mining) Ex-proof, CULUS certification DHZA/UL A = without integral electronic AE = with integral electronic (not for DHRZA*) P * = pilot valve (consult our technical office) 010= reduced port A 012= reduced ports A and B 25 = reduced pressure range 3 25 bar Optional cable gland (only for DHRZA*, not for /UL): PA = with threated cable gland, see section 10 (1) Only for DHRZA, not for Group I, Atex (mining) Series Seals material: - = NBR PE = FKM BT = HNBR Only for -A execution - = standard coil for 24VDC Atos drivers 6 = optional coil for 12VDC Atos drivers 18 = optional coil for low current drivers 24 = with 24 VDC coils (only for DHRZA) Options: B = for reduced port B only for DHRZO-AE: I = current reference (4 20 ma) Q = enable signal only for DHRZA*: O = horizontal cable entrance (not for DHRZA/M) WP = prolongued manual override protected by metallic cap Solenoid threated connection, only for DHRZA: GK = GK-1/2 ISO/UNI-6125 (tapered) - not for /UL NPT = 1/2 NPT ANSI/ASME B1.20.1 (tapered) M = M20x1,5 UNI-4535 (6H/6g) - not for /UL TF040

2 CERTIFICATIONS FOR DHRZA In the following are resumed the valves marking Multicertifications Group II and Group I (mining) or CULUS 2.1 GROUP II, ATEX marking II 2 G = Solenoid for surface plants with gas and vapors environment, category 2, suitable for zone 1 and zone 2 II C = Equipment of group IIC suitable for substances (gas) of group IIC T6/T4 = Solenoid temperature class (maximum surface temperature) Gb = Equipment protection level, high level protection for explosive Gas atmospheres = Mark of conformity to the applicable European directives II 2 D = Solenoid for surface plants with dust environment, category 2, suitable for zone 21 and zone 22 III C = Suitable for conductive dust (applicable also IIIB and/or IIIA) T85/T135 = Maximum surface temperature (Dust) Db = Equipment protection level, high level protection for explosive Dust atmospheres = Mark of conformity to the 94/9/CE directive and to the technical norms 2.2 GROUP II, IECEx marking IIC = Equipment of group IIC suitable for substances (gas) of group IIC T6/T4 = Solenoid temperature classes (Gas) Gb = Equipment protection level, high level protection for explosive Gas atmospheres Ex tb = Equipment protection by enclosure tb IIIC = Suitable for conductive dust (applicable also IIIB and/or IIIA) T85 C/T135 C = Maximum surface temperature (Dust) Db = Equipment protection level, high level protection for explosive Dust atmospheres 2.3 ROSTECHNADZOR marking Rostechnadzor certification acknowledges the whole ATEX Directive 94/9/EC. This certification is available only for gas environment (not for dust). II 2 G Ex d II C = Solenoid for surface plants with gas and vapors environment, category 2, suitable for zone 1 and zone 2 = Explosion-proof equipment = Equipment of group IIC suitable for substances (gas) of group IIC T6/T4 = Solenoid temperature class (maximum surface temperature) = Mark of conformity to the 94/9/CE directive and to the technical norms 2.4 GROUP I, ATEX (mining) = ATEX identification for explosive atmospheres equipments I = Group I for mines and surface plants M2 = High protection (equipment category) I = Gas group (Methane) Mb = Equipment protection level, high level protection for explosive atmospheres Atex notified ATEX Directive IECEx notified IECEx Directive Russian notified ATEX Directive Atex notified Atex Directive IECEx notified IECEx Directive Note: According to EN60079-0 the valves with Atex certification can be coated with a non-metallic material (for ex. paintened), observing the maximum thickness: Group IIC = 0,2 mm max 2.5 GROUP I, IECEx (mining) I = Group I for mines and surface plants M2 = High protection (equipment category) I = Gas group (Methane) Mb = Equipment protection level, high level protection for explosive atmospheres 2.6 CULUS Class I Division 1 Groups C&D Groups IIA&IIB T4 = Equipment for famable gas and vapours = Possibility of explosive atmosphere during normal functioning = Gas group ( UL 1002) = Gas group ( NEC 505-7) = Temperature class of solenoid surface referred to +70 C ambient temperature Note: According to EN60079-0 the valves with Atex certification can be coated with a non-metallic material (for ex. paintened), observing the maximum thickness: Group IIC = 0,2 mm max NEC 505-7 norms UL 1002 norms CULUS identification mark WARNING: service work provided on the valve by the end users or not qualified personnel invalidates the certification

3 HYDRAULIC CHARACTERISTICS Hydraulic symbols Coil resistance R at 20 C Max solenoid current Max power Duty factor DHRZO-A(E)-010/25* DHRZA-A-010/25* Max regulated pressure (Q = 1 l/min) [bar] Min. regulated pressure (Q = 1 l/min) [bar] Max. pressure at port P [bar] Max. pressure at port T [bar] Max. flow [l/min] Response time 0-100% step signal (depending on installation) [ms] Hysteresis [% of the max pressure] Linearity [% of the max pressure] Repeatability [% of the max pressure] DHRZO-A(E)-010/25/B* DHRZA-A-010/25/B* Above performance data refer to valves coupled with Atos electronic drivers, see section 25 3 315 210 DHRZO-A(E)-012/25* DHRZA-A-012/25* 3 3,3 Ω for standard 12 VDC coil; 2 2,2 Ω for 6 VDC coil; 13 13,4 Ω for 18 VDC coil; 2,6 A for standard 12 VDC coil; 3,5 A for 6 VDC coil; 1,5 A for standard 18 VDC coil; 40 Watt Continuous rating (ED=100%) 24 45 1,5 3 2 4 MAIN CHARACTERISTICS, SEALS AND HYDRAULIC FLUID - for other fluids not included in below table, consult our technical office Assembly position / location Any position for all valves Subplate surface finishing Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101) NBR seals (standard) = -20 C +60 C, with HFC hydraulic fluids = -20 C +50 C Seals, recommended fluid temperature FKM seals (/PE option) = -20 C +80 C HNBR seals (/BT option) = -40 C +60 C, with HFC hydraulic fluids = -40 C +50 C Recommended viscosity 15 100 mm 2 /s - max allowed range 2.8 500 mm 2 /s Fluid contamination class ISO 4406 class 21/19/16 NAS 1638 class 10, in line filters of 25 μm (β10 _>75 recommended) Hydraulic fluid Suitable seals type Classification Ref. Standard Mineral oils NBR, FKM, HNBR HL, HLP, HLPD, HVLP, HVLPD DIN 51524 Flame resistant without water FKM HFDU, HFDR Flame resistant with water NBR, HNBR HFC ISO 12922 5 EXPLOSION PROOF SOLENOIDS FOR DHRZA: MAIN DATA SOLENOID TYPE PROPORTIONAL without transducer Solenoid Multicertification for Group II OA code Multicertification for Group I (mining) OAM Voltage VDC ±10% 12DC, 24DC, 28DC, 48DC, 110DC, 125DC, 220DC code VAC 50/60 Hz ±10% 12AC, 24AC, 110-120AC, 230-240AC (1) Power consumption 8W Coil insulation Class H Protection degree IP 66/67 According to IEC 144 when correctly coupled with the relevant cable gland PA*, see section 16 Duty factor 100% Mechanical construction Flame proof housing classified Ex d, EN 60079-0: 2006, EN 60079-1: 2007 Cable entrance and Internal terminal board for cable connection. Threaded connection for cable entrance, electrical wiring vertical (standard) or horizontal (option /O). See section 26 for cable gland Method of protection Ex d Temperature class (only for Group II) T6 T4 Surface Multicertification for Group II 85 C 135 C temperature Multicertification for Group I (mining) 150 C Ambient Multicertification for Group II -40 +45 C (2) -40 +70 C (2) temperature Multicertification for Group I (mining) -20 +70 Temperature class (only for CULUS) T4 (with +70 C ambient temperature) Surface temperature 135 C Ambient temperature -40 +70 C (1) The Group II solenoids are certified ATEX and IECEx for minimum ambient temperature -40 C. In case the complete valve must withstand with minimum ambient temperature of -40 C, select /BT in the model code TF040

6 DIAGRAMS based on mineral oil ISO VG 46 at 50 C [A-T] [B-T] [P-A] [P-B] Regulated pressure [bar] Pressure reduced [bar] Reference signal [% of max] Flow [l/min] 7 INSTALLATION DIMENSIONS FOR DHRZO [mm] M ISO 4401: 2005 Mounting surface: 4401-03-02-0-05 (see table P005) Fastening bolts: 4 socket head screws M5x50 class 12.9 Tightening torque = 8 Nm Seals: 4 OR 108; Diameter of ports A, B, P, T: Ø 7,5 mm (max) DHRZO-A-010/25* DHRZO-AE-010/25* 8 DHRZA SOLENOIDS DIMENSIONS [mm] AND WIRING FOR MULTICERTIFICATION OZA-A Option /O Option /WP Option /OWP = screw terminal for additional equipotential grounding = Solenoid wiring 1 = Coil 2 =GND 3 = Coil

9 DHRZA SOLENOIDS DIMENSIONS [mm] AND WIRING FOR UL OZAUL-A Option /O Option /WP Option /OWP Screw terminal for additional equipotential grounding Solenoid wiring red = Coil green = GND black = Coil The valves are supplied with 1,07m (42 inches) cable lenght, factory wired 10 CABLE GLAND FOR DHRZA Cable gland PAMC/* (IP66/67) for valves with multicertification Group II PAMC/M PAMC/NPT PAMC/GK Cable size 6,5 to 11,9 mm The cable glands PAMC, are Multicertified : ATEX: EN 60079-0, EN 60079-1, EN 60079-7 and EN 60079-31 IECEx: IEC 60079-0, IEC 60079-1, IEC 60079-7 and IEC 60079-31 Rost: EN60079-0 and EN60079-1 ~35 ~55 CH.24 Following codes have to be specified for spare cable glands: PAMC/GK =with threated connection GK-1/2 ISO/UNI-6125 (tapered) PAMC/NPT =with threated connection 1/2 NPT ANSI B2.1 (tapered) PAMC/M =with threated connection M20x1,5 UNI-4535 (6H/6g). M20x1.5 or 1/2 NPT CH.24 1/2 GK CH.30 The cable must be suitable for the working temperature as specified in the safety instructions delivered with the first supply of the products. Additional equipotential grounding can be also performed by the user on the external facility provided on the solenoid case. Minimum section of external ground wire = 4 mm 2. Minimum section of internal ground wire = the same of supply wire. The cable glands must be blocked with loctite or similar or with a lock nut. The valves must be connected to the power supply using the terminal board inside the solenoid. 01/15