Solenoid Valves Type 3963

Similar documents
Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Limit Switch Type 3776

Solenoid Valve Island Type 3965

3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4" and 1 /2" 5/2 Way Solenoid Valve 1 /4" 6/2 Way Solenoid Valve 1 /4" 5/3 Way Solenoid Valve 1 /4"

Series 3730 Electropneumatic Positioner Type

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Limit Switch Type 3776

Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Limit Switch Type 4747

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Type 4746 Electric or Pneumatic Limit Switch

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Mounting and Operating Instructions EB 5868/5869 EN

Electronic Limit Switch Type

EB EN. Translation of original instructions. Type 3766 Pneumatic Positioner

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

Solenoid Valve Type 3962

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

Type Electronic Limit Switch

Type 3967 Solenoid Valve

Electropneumatic Positioner Type Fig. 1 Type Mounting and Operating Instructions EB EN

Series 3730 Type Electropneumatic Positioner. Fig. 1 Type Mounting and Operating Instructions EB EN ( )

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

HERION SERIES Indirect solenoid actuated soft seal

Our policy is one of continued research and development. We therefore reserve the right

97100 NAMUR. Technical data

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

System 6000 Electropneumatic Converters for DC ranges I/P Converter Type 6102 Type 5288

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

Our policy is one of continued research and development. We therefore reserve the right

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

97105 Inline. Ordering information. Technical data. Accessories See page 5

TZIM. Electropneumatic Analog Positioner 10/ EN

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

Mounting and Operating Instructions EB EN ( ) Series 3730 Type Electropneumatic Positioner

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Mounting and Operating Instructions EB EN ( ) Series 3730 Type Electropneumatic Positioner. with PROFIBUS-PA communication

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Assembly. Trunk IN + - S U, I U, I. Spur 1

Series 240 Type Gas and Type Gas Automatic Shut-off Valves for Gases (valve class D)

Electropneumatic positioner APIS

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Mounting and Operating Instructions EB 8392 EN. Series 3710 Type 3710 Reversing Amplifier

Pneumatic control unit for decentralized automation of ELEMENT process valves

24010, 3/2 Direct solenoid actuated poppet valve

Series 240 Pneumatic Control Valves Type and Type Three-way Valve Type 3244

4.3 MSK SWITCH BOX MSK (SIZE I) FEATURES ADVANTAGES

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

Mounting and Operating Instructions EB EN. Series 3730 Electropneumatic Positioner Type with HART communication and pressure sensors

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

Type 3379 Pneumatic Actuator. Mounting and Operating Instructions EB 8315 EN

Series 240 Pneumatic Control Valve Type and Type Three-way Valve Type 3244

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

Mounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type

Series 240 Type and Type Pneumatic Control Valves Type 3347 Hygienic Angle Valve

Data Sheet T EN

Competence in Functional Safety MANUAL. principle and typical applications

T 8053 EN Type and Type Pneumatic Control Valves Type 3252 High-pressure Valve

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Pneumatic Control Valve Assembly Type 3331/3278

Series 250 Pneumatic Control Valve Type and Type High Pressure Valve Type 3252

Typetested for liquid fuels and liquefied petroleum gas (LPG) in the liquid phase (see Data Sheet T 8022 EN) Version according to ANSI standards

Series Level-Trol Electronic Liquid Level Transmitters

Series 250 Pneumatic Control Valves Type and

Valve Accessories. Limit switches, solenoid valves, lock-up valves, supply pressure regulators, volume boosters, quick exhaust valves, applications

Series 240 Pneumatic Control Valve Type and Type Globe Valve Type 3241

Flow direction: Fixed. G1/4, G1/2 NAMUR G1/ Aluminium xxxx***** G1/4, G1/2 NAMUR G1/ Stainless steel xxxx*****

Maxifluss Rotary Plug Valves VETEC Types 73.3/M and 73.7/M

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Pneumatic Controller for Temperature. Type Pneumatic Controller for Temperature. Type Mounting and Operating Instructions EB 7065 EN

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Series W&T Pneumatic Control Valve Type RVG Globe valve and angle valve

Series 430 Type 3430 Pneumatic Indicating Controller for Temperature with Capillary Sensor Type 3432 Controller Station Type 3436 Transmitter Module

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Transcription:

Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate storage are assumed. The air supply must not exceed the maximum permissible pressure and, if necessary, it must be limited by a pressure reducer. The devices can be mounted in any desired position. The filter in the enclosure cover and the cable gland M 20 1.5 must be installed hanging downwards, or if this is not possible, horizontally. The required degree of protection according to IEC 60529:1989 can be only guaranteed with attached enclosure cover, integrated exhaust air filters and proper installation of the connections. On mounting, make sure that a clearance of minimum 300 mm above the enclosure cover is kept. In locations where there is a risk of mechanical damage to the enclosure, the enclosure must be fitted with additional protection to fulfill the Edition: March 2009 requirements in paragraph 6 of EN 61241-0: 2006 ( Electrical apparatus for use in the presence of combustible dust ). If the device is mounted to a rotary actuator or linear actuator with positioner, it is necessary to change over the air supply to an external supply at connection 9 (see page 7 ff.). The minimum permissible ambient temperature is 20 C (Type 3963-XXXXXXXXXXXX0) and 45 C (Type 3963-XXXXXXXXXXXX1). The permissible ambient temperature is lowered for intrinsically safe devices in accordance with the EC Type Examination Certificate PTB 01 ATEX 2085 and the Statement of Conformity PTB 01 ATEX 2086 X (see pages 10 and 11). Refer to Data Sheet T 3963 EN for technical data, ordering data, spare parts and accessories. Contents General Page 1 Mounting Page 2 Air connection Page 6 Electrical connection Page 9 Approvals Page10 EB 3963 EN

Mounting Rail mounting Type 3963-XXX0011/-XXX0012/ -XXX0111/-XXX1011/ -XXX8011 These devices can be attached with two mounting bases for G-profile rail 32 according to EN 50 035 or top hat rail 35 according to EN 50 022 (Fig. 2). Wall mounting Mounting base for G-profile rail 32 (Order no. 1400-5930) 38 63 M 3 x 8 DIN 84 Mounting base for top hat rail 35 (Order no. 1400-5931) 38 Type 3963-XXX0011/-XXX0012/ -XXX0111/-XXX1011/ -XXX8011 These devices can be attached to a wall mounting plate (Fig. 2). Type 3963-XXXX013/-XXXX014 These devices can be attached with screws through bore holes (Fig. 3). 63 Wall mounting plate (Order no. 1400-6726) ø6 38 M 3 x 8 DIN 84 M 3 x 8 DIN 912 25 63 82 94 Fig. 2 Dimensions in mm Type 3963-XXXX014 Type 3963-XXXX013 63 29 29 63 29 63 189 169 22 5 1 3 4.3 4 2 22 4.3 5 4 1 3 32 2 50.8 244 7 21 21 32 52 61 30 52 3 45 32 50.8 Fig. 3 Dimensions in mm EB 3963 EN 2

Mounting to rotary actuators with NAMUR interface according to VDI/VDE 3845 Type 3963-XXXXX0 These devices can be directly attached to rotary actuators with NAMUR interface (Fig. 4). Before mounting, check that the two O-rings are positioned correctly. The operation direction is determined by a threaded coding pin M5 10 DIN 916 on the mounting flange of the rotary actuator. The device is attached with two screws M 5 35 ISO 4762. The mounting accessories are delivered together with the device. Mounting to restrictor block for single-acting rotary actuators with NAMUR interface according to VDI/VDE 3845 NAMUR interface according to VDI/VDE 3845 32 24 Type 3963-XXX1003 These devices can be attached to a restrictor block for rotary actuators with NAMUR interface (Fig. 5). The restricting function can be identified from the symbol indicated on the device. Different closing and opening times can be adjusted in a ratio of 1:15 by turning the restricting screws clockwise or counterclockwise with a screwdriver. 12 8M 5 Threaded coding pin G 1 / 4 2 Fig. 4 Dimensions in mm Mounting to restrictor block (Order no. 1400-6763) for single-acting rotary actuators 29 63 96 9 122 5 1 3 4 2 5 1 47 55 25.4 75 Fig. 5 Dimensions in mm 3 EB 3963 EN

Mounting with adapter plate to linear actuators with NAMUR rib according to IEC 60534-6-1 Type 3963-XXX0X0 These devices can be mounted with an adapter plate (Fig. 6) to linear actuators with a NAMUR rib. When both a positioner and limit switch are to be mounted on linear actuators with nominal size DN 50, a bracket (Order no. 0320-1416) is required. Mounting with CrNiMo steel pipe fittings to linear actuators Adapter plate NAMUR rib/namur interface (Order No. 1400-6751) 60 15 30 1.3 2.3 92 30 Type 3963-XXX0X1X0/-XXX0X142 These devices can be mounted using a CrNiMo steel pipe fitting to linear actuators, e. g. SAMSON Type 3271 or 3277 (Fig. 7). Refer to Mounting and Operating Instructions EB 8310 EN and EB 8311 EN. G 1 / 2 M 8 x 35 DIN 912 10 25 25 12 12 2.3 ø8 1.3 M 5 14 32 Fig. 6 Dimensions in mm Mounting with CrNiMo steel pipe fittings to linear actuators A 97 45 Actuator size Connection A Order no. 80/240 cm 2 G 1 / 4 / 1 / 4 64 1400-6759 350/700 cm 2 G 3 / 8 / 1 / 4 75 1400-6761 G 3 / 8 / 1 / 2 64 1400-6735 Actuator size Connection Order no. 1400 cm 2 G 3 / 4 / 1 / 2 1400-6736 2100 cm 2 G 1 / 1 / 2 1400-6737 2800 cm 2 Fig. 7 Dimensions in mm EB 3963 EN 4

Mounting to connection block for SAMSON Type 3277 Linear Actuator Type 3963-XXX0X3 These devices can be mounted to a connection block for SAMSON Type 3277 Linear Actuator with SAMSON Type 3730-X, 3731-X, 3766, 3767 or 378X Positioner (Fig. 8). Before mounting, check that the four O-rings are positioned correctly on the mounting flange. The device is attached with two screws M 5 55 ISO 4762. The mounting accessories are delivered together with the device. Refer to mounting and operating instructions of the corresponding SAMSON devices. Mounting to linear actuators with NAMUR rib according to IEC 60534-6-1 Type 3963-XXX002 This device can be directly mounted to a linear actuator with NAMUR rib. The device is attached with a screw M 8 35 ISO 4762 which is delivered with the device. Mounting to connection block for SAMSON Type 3277 Linear Actuator A B Type 3963-XXX0X3 Connection block G 1 / 4 (Order no. 1400-8813) 1 / 4 NPT (Order no. 1400-8814) with piping kit for "Stem retracts" A-B Mounting flange 190 390* *Clearance for mounting of enclosure cover Fig. 8 Dimensions in mm 29 90 5 EB 3963 EN

Air connection The air supply pipes and screw fittings must be mounted by experienced personnel only. They must be regularly checked for leakage and damage, and if necessary, repaired. Before starting any repair work, all supply pipes which are to be opened must be depressurized. The air connections are G (NPT) 1 / 4 or G (NPT) 1 / 2 tapped holes depending on the version. The exhaust air connections must be protected against water and dust by using filters or other suitable measures. Note: The K vs value of a pressure reducer connected upstream must be at least 1.6 times larger than the K vs value of the device. Supply pipe The minimum required nominal size of the supply pipe is shown in the following table: Nominal size (Supply pipe length 2 m) Press- K vs value ure 0.16 1.4 4.3 0.32 Connection (bar) 4 1 and 3 4 9 1.4 DN 6 DN 8 DN10 DN 4 2.5 DN 4 DN 6 DN 8 6 DN 4 DN 6 Note: Larger nominal sizes must be used for supply pipe lengths over 2 meters. Operating medium for the booster valve With internal air supply: Instrument air, free of corrosive particles, or nitrogen, pressure 1.4 to 6 bar. With external air supply via connection 9 (see page 7 ff.): Instrument air, free of corrosive particles, oilcontaining air or noncorrosive gases, pressure 0 to 6 bar (0 to 10 bar for K vs value 1.4 or 4.3 with air supply via connection 4). Air supply for the pilot valve Instrument air, free of corrosive particles, or nitrogen, pressure 1.4 to 6 bar. Quality of compressed air according to ISO 8573-1 Particle size Oil contents Pressure and density dew point Class 4 Class 3 Class 3 5 µm 1 mg/m 3 20 C or at and least 10 K 1 000/m 3 below the lowest ambient temperature to be expected Note for using nitrogen: When the devices are to be mounted in closed, unventilated rooms, the exhaust air of pilot valves or booster valves must be vented to the outside over a central pipe. Type 3963-XXXX0X3/-XXXX014 In the aboved listed devices, it is possible to check whether the nominal size of the supply pipe is sufficient as follows: 1. Unscrew the screw plug covering connection 9 and connect a pressure gauge. 2. The nominal size of the supply pipe proves to be sufficient when there is a pressure of 1.3 bar during the switching process. EB 3963 EN 6

Conversion to external air supply via connection 9 When the output signal (0 to 6 bar) of a positioner has to be switched by the solenoid valve, the air supply is to be connected external via connection 9. Installation of the gasket for Type 3963-XXXX004/-XXXX007/ -XXXX014 Type 3963-XXXX004/-XXXX007/ -XXXX014 In these devices, if not otherwise specified, the air supply is connected internally via connection 4. It can be converted to an external air supply via connection 9 (Fig. 9) as follows: 1. Unscrew the filister head screw and remove plate and gasket from the connecting plate. 2. Turn gasket by 90. The tab of gasket is then placed in cutout 9 of the connecting plate. 3. Refasten plate and gasket to the connecting plate. Note: In these devices, the flat gasket must be inserted as described for Internal air supply via connection 4 (Fig. 11, page 8). Type 3963-XXXX0X3/-XXXX006 In these devices, if not otherwise specified, the air supply is connected internally via connection 1 or 3. It can be converted to an external air supply via connection 9 (Fig. 10) as follows: 1. Unscrew the filister head screw and remove plate and gasket from the connecting plate. 2. Turn gasket by 180. The tab of gasket is then placed in cutout 9 of the connecting plate. 3. Refasten plate and gasket to the connecting plate. Note: In case of double actuated booster valves, this conversion must be performed in both pilot valves. Fig. 9 Installation of the gasket for Type 3963-XXXX0X3/-XXXX006 Fig. 10 7 EB 3963 EN

Type 3963-XXX0002/-XXX0012/ -XXX0022/-XXX1011 In these devices, if not otherwise specified, the air supply is connected internally via connection 4. It can be converted to an external air supply via connection 9 (Fig.11) as follows: 1. Unsrew the four filister head screws and remove enclosure cover. 2. Unsrew the three hexagon socket head screws and remove solenoid valve from the adapter plate. 3. Turn flat gasket by 180. The tab of the flat gasket is then placed in cutout 9 of the enclosure. 4. Refasten solenoid valve and adapter plate. Type 3963-XXX0001/-XXX0011/ -XXX0032/-XXX0101/ -XXX0111/-XXX0131/ -XXX1001/-XXX1201/ -XXX8001 The air supply cannot be diverted in these devices. The flat gasket, if provided, must be inserted as described for Internal air supply via connection 4 (Fig. 11). Exhaust air return Installation of the flat gasket for Type 3963-XXX0002/-XXX0012/ -XXX0022/-XXX1011 Int Fig. 11 [3] Internal air supply via connection 4 Setting of the restrictors [3] External air supply via connection 9 9 Type 3963-XXX0013X The connection 4 is sealed by a screw plug in the delivered state. If the exhaust air return is used for spring-loaded actuators, the screw plug must be removed and connection 4 must be connected to the spring chamber of the actuator by a hose with nominal size DN 4 to 10 (depending on the actuator size). 2.3 _ + 1.3 Manual operation (optionally) Restrictors Type 3963-XXXX1/-XXXX2/-XXXX3 These devices have one or two restrictors. The restricting function can be identified from the symbol indicated on the device. Different closing and opening times can be adjusted in a ratio of 1:15 by turning the restricting screws clockwise or counterclockwise with a screwdriver. The restricting screws can be found underneath the enclosure cover or at the adapter plate (Fig. 12). Type 3963-XXXX1/-XXXX2 1.3 4 Type 3963-XXXX3 Fig. 12 EB 3963 EN 8

Electrical connection As far as the electrical installation of the device is concerned, the relevant electrotechnical regulations and the accident prevention regulations of the country in which the device is used must be observed. In Germany these are the VDE regulations and the accident prevention regulations of the employers liability insurance association. For installation in hazardous areas, the respective national regulations of the country in which the device is used applies. In Germany these are VDE 0165/EN 60079. For connection to certified intrinsically safe electric circuits, the EC Type Examination Certificate PTB 01 ATEX 2085 for Zone 1 and Certificate of Conformity PTB 01 ATEX 2086 X for Zone 2 or 22 applies (see pages 10 to11). On connecting DC voltage signals, observe the correct polarity. Do not tamper with painted screws in the enclosure. Connection diagrams 81 82 + _ Terminals in the enclosure 8 2 7 6 5 3 4 + _ blue brown The power supply is connected either through a cable gland M 20 1.5 to the terminals in the enclosure or with a plug-type connector (Fig. 13). Female connector (manufactured by Harting) Cable It is recommended that connecting cables with a conductor cross-section of 0.5 to 2.5 mm 2 are used. Connecting cables with an external diameter of 6 to 12 mm are suitable for the cable gland M 20 1.5. blue _ 2 1 3 + brown Degree of protection Female connector acc. to EN 175301-803 The devices can be changed from degree of protection IP 54 to degree of protection IP 65 by exchanging the filter in the enclosure cover. Manual operation The devices have a manual operation as an alternative to allow the device to be manually operated when a nominal signal is not available: Switch in the enclosure cover Push button in the enclosure cover Pushbutton underneath enclosure cover (see page 8, Fig. 12) Note: For safety circuits, only devices without manual operation should be used. blue _ + 2 1 3 4 Female connector M 12 1 Fig. 13 brown 9 EB 3963 EN

Approvals EC Type Examination Certificate PTB 01 ATEX 2085 dated 08.08.2001 (extract) for Type 3963-1X Solenoid Valve (device index 13 or higher) II 2 G EEx ia IIC T6 for use in hazardous areas (Zone 1) The correlation between version, temperature class, permissible ambient temperature and maximum permissible power dissipation is shown in the following table: Type 3963-11 3963-12 3963-13 Nominal signal U N 6 V DC 12 V DC 24 V DC Ambient temperature *) 45 to 60 C (temperature class T6) 45 to 70 C (temperature class T5) 45 to 80 C (temperature class T4) Power dissipation P i 250 mw No limitation Internal inductance L i Negligible Internal capacitance C i Negligible *) The minimum permissible ambient temperature is limited to 20 C for Type 3963-1XXXXXXXXXXX0 due to the materials of the filter and the electrical connection used For connection to a certified intrinsically safe circuit the permissible maximum values are shown in the following table: Voltage U i 25 V 27 V 28 V 30 V 32 V Current I i 150 ma 125 ma 115 ma 100 ma 90 ma Note: The EC Type Examination Certificate is available on request. For use in hazardous areas (Zone 21) a manufacturer s declaration is available on request. Model number and device index The model number and the device index are shown on the nameplate: 3963-XXXXXXXXXXXXXXXXX XX Model number Device index EB 3963 EN 10

Statement of Conformity PTB 01 ATEX 2086 X dated 14.11.2001 (extract) for Type 3963-8X Solenoid Valve (device index 13 and higher) II 3 G EEx na II T6 for use in hazardous areas (Zone 2 or 22) The correlation between version, temperature class and permissible ambient temperature is shown in the following table: Type 3963-81 3963-82 3963-83 Nominal signal U N 6 V DC 12 V DC 24 V DC Ambient temperature *) 45 to 60 C (temperature class T6) 45 to 70 C (temperature class T5) 45 to 80 C (temperature class T4) *) The minimum permissible ambient temperature is limited to 20 C for Type 3963-8XXXXXXXXXXX0 due to the materials of the filter and the electrical connection used Special conditions The required degree of protection IP 54 according to IEC 60529:1989 is only guaranteed with correct installation of the enclosure cover and electrical connection. The wiring shall be connected in such a manner that the connecting cables are not subjected to tensile and torsional load. Model number and device index The model number and the device index are shown on the nameplate: 3963-XXXXXXXXXXXXXXXXX XX Model number Device index 11 EB 3963 EN

Addendum to EB 3963 EN (Revisions Control Number: 1 May 2005) Installation directions for devices certified by CSA for use in hazardous locations The devices may be installed in intrinsically safe circuits only when used in conjunction with the CSA certified devices (see Fig. 14). The permissible maximum values of U i or V max,i i or I max,p i or P max,c i and L i for the intrisically safe circuit are shown in the following table: Solenoid valve Type U i or V max I i or I max P i or P max C i L i 3963-11 ( 6 V DC) 28 V 784 ma 250 mw 0 nf 0 µh 3963-12 (12 V DC) 28 V 240 ma No limitation 0 nf 0 µh 3963-13 (24 V DC) 28 V 240 ma No limitation 0 nf 0 µh Note: U 0 or V 0C U i or V max / I 0 or I max I i or I max / P 0 P i or P max / C 0 C i / L 0 L i For barrier selection see the following table. In case of doubt as regards barrier selection, contact the manufacturer. Solenoid valve Supply barrier Evaluation barrier Type V max R min V max 3963-11 ( 6 V DC) 28 V 280 28 V Diode return 3963-12 (12 V DC) 28 V 280 28 V Diode return 3963-13 (24 V DC) 28 V 280 28 V Diode return The correlation between temperature class and permissible ambient temperature is shown in the following table: Temperature class Permissible ambient temperature T 6 45 to 60 C T 5 45 to 70 C T 4 45 to 80 C Installation shall be in accordance with the Canadian Electrical Code Part. Use only supply wires suitable for 5 C above ambient temperature. EB 3963 EN 12

Connection diagrams CSA certified for hazardous locations: Ex ia IIC; Class I, Zone 0 Class I; Groups A, B, C, D Class II; Groups E, F, G; Class III Type 4 enclosure Hazardous Location Safe Location Type 3963-3 Solenoid Valve 81 82 Solenoid valve circuit Relay or transistor output Supply barrier Evaluation barrier Note: Cable entry only rigid metal conduit according to drawings 1050-0539 T and 1050-0540 T Intrinsically safe ground CSA certified for hazardous locations: Class I; Division 2, Groups A, B, C, D Class II; Division 2, Groups E, F, G; Class III Type 4 enclosure Hazardous Location (Div. 2) Safe Location Type 3963-3 Solenoid Valve 81 82 Valve Circuit Unspecified apparatus, e.g. transistor relay, transmitter Note: Cable entry only rigid metal conduit according to drawings 1050-0539 T and 1050-0540 T Ground Fig. 14 13 EB 3963 EN

Addendum to EB 3963 EN (Revisions Control Number: 1 August 2004) Installation directions for devices certified by FM for use in hazardous locations The devices may be installed in intrinsically safe circuits only when used in conjunction with the FM certified devices (see Fig. 15). The permissible maximum values of U i or V max,i i or I max,p i or P max,c i and L i for the intrisically safe circuit are shown in the following table: Solenoid valve Type U i or V max I i or I max P i or P max C i L i 3963-11 ( 6 V DC) 28 V 784 ma 250 mw 0 nf 0 µh 3963-12 (12 V DC) 28 V 240 ma No limitation 0 nf 0 µh 3963-13 (24 V DC) 28 V 240 ma No limitation 0 nf 0 µh Note: U 0 or V 0C U i or V max / I 0 or I max I i or I max / P 0 P i or P max / C 0 C i / L 0 L i The devices may be installed in intrinsically safe circuits only when used in conjunction with the FM approved safe barrier. In case of doubt as regards barrier selection, contact the manufacturer. For the permissible barrier parameters for the circuit see the following table: Solenoid valve Supply barrier Evaluation barrier Type V 0C R min I 0C V 0C R min I 0C 3963-11 ( 6 V DC) 28 V 784 115 ma 28 V # 0 ma 3963-12 (12 V DC) 28 V 240 115 ma 28 V # 0 ma 3963-13 (24 V DC) 28 V 240 115 ma 28 V # 0 ma The correlation between temperature class and permissible ambient temperature is shown in the following table: Temperature class Permissible ambient temperature T 6 45 to 60 C T 5 45 to 70 C T 4 45 to 80 C Installation shall be in accordance with the National Electrical Code ANSI/NFPA 70 and ANSI/ISA RP 12.06.01. Use only supply wires suitable for 5 C above ambient temperature. EB 3963 EN 14

Connection diagrams FM approved for hazardous locations: A Ex ia IIC T6; Class I, II, III, Division 1, Groups A, B, C, D, E, F, G NEMA 4X Hazardous Location Safe Location Type 3963-3 Solenoid Valve 81 82 Solenoid valve circuit Relay or transistor output Supply barrier Evaluation barrier Note: Cable entry only rigid metal conduit according to drawings 1050-0539 T and 1050-0540 T Intrinsically safe ground FM approved for hazardous locations: Class I; Division 2, Groups A, B, C, D Class I, Class II; Division 2, Groups F, G Class III NEMA 4X Hazardous Location (Div. 2) Safe Location Type 3963-3 Solenoid Valve 81 82 Valve Circuit Unspecified apparatus, e.g. transistor relay, transmitter Note: Cable entry only rigid metal conduit according to drawings 1050-0539 T and 1050-0540 T Ground Fig. 15 15 EB 3963 EN

Specifications subject to change without notice. SAMSOMATIC GMBH A member of the SAMSON GROUP Weismüllerstraße 20 22 60314 Frankfurt am Main Germany Phone: 49 69 4009-0 Fax: 49 69 4009-1644 E-mail: samsomatic@samson.de Internet: http://www.samsomatic.de 2009-03 EB 3963 EN