Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification ATEX, IECEx, EAC or CULUS certification

Similar documents
DHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W

Solenoid directional valves type DHAL8 and DHWL8 direct operated, ISO 4401 size 06, ex-proof or intrinsically safe, low leakage execution

Ex-proof ISO cartridge valves multicertification ATEX, IECEx, EAC or North American certification CULUS directional control, ISO 7368

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

ISO cartridge valves type LIDD and LIQV Flow control, ISO 7368 sizes 16 63

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

Safety cartridge valves with poppet position monitoring

ISO cartridge valves type LIDEW* and LIDBH*

Solenoid directional valves Pmax 420 bar direct operated, ISO 4401 size 06 and size 10

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06

SOLENOID DIRECTIONAL VALVE

Pressure control valves type AGIR, AGIS, AGIU two stage, subplate mounting, ISO 5781 sizes 10, 20 and 32

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES

ISO cartridge valves type LIM*, LIRA, LIC*

Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - ATEX or IECEx certification

Pressure relief valves type ARAM

Proportional relief valves

Safety directional valves with spool position monitoring

Proportional reducing valves

Solenoid directional valves type DPHI and DPHE two stage, ISO 4401 size 10, 16, 25 and 32

Proportional reducing valves

Proportional relief valves with integral pressure transducer

Proportional reducing valves with integral pressure transducer

Proportional reducing valves

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

Proportional relief valves with integral pressure transducer

2/2 Solenoid Cartridge Valve, Size 6

VSD*HL-*-KD2 - HAZARDOUS LOCATION, SOLENOID, DIRECT & PILOT OPERATED VALVES

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

Q max (see specifications table)

Proportional flow valves

DXPE*J /117 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 31

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Directional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents. RE Edition: Replaces:

p max (see table of performances) Q max (see table of performances) MD1K MD1KD bar

Directional Control Valve

Directional spool valves, direct operated, with solenoid actuation. Type WE

Chapter 2: Directional Control Valves

Proportional relief valves with integral pressure transducer

VALIADIS S.A. HELLENIC MOTORS

Directional spool valves, direct operated, with solenoid actuation. Type WE. Contents. Features. RE Edition: Replaces:

solenoid valves

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

Complementary safety valves with /FC mechanical microswitches conforming to Machine Directive 2006/42/CE

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min

DFE. solenoid control monoblock valve. Content. Working conditions Hydraulic circuit DFE052. Dimensional data Ordering codes...

Proportional pressure reducing valve, pilot operated. Type DRE(M) and DRE(M)E. Features. Contents. RE Edition: Replaces: 11.

Solenoid directional valves type DPHI, DPHE, DPHER two stage, ISO 4401 size 10, 16, 25 and 32

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Explosion-Proof Valves. According to Directive 94/9/EC (ATEX) and IECEx Requirements

Directional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

Directional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents. RE Edition: Replaces: 04.

Directional Control Valve Series D3W Soft Shift

Solenoid directional valves type DPHI, DPHU

Safety valves direct, pilot operated and cartridge execution

Proportional pressure reducing valve, pilot operated

Proportional directional valves digital, direct operated, open loop, with positive spool overlap

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

3/2 directional spool valve, direct operated with solenoid actuation

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

3/2 and 4/2 directional seat valves with solenoid actuation

INSTRUCTION MANUAL (ATEX / IECEx)

EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 5X CENELEC STANDARD & ATEX DIRECTIVE

Directional Control Valve Series D1VW

Proportional Flow-Control Cartridges, Size 5

VED*MJ PILOT OPERATED DIRECTIONAL CONTROL VALVES WITH OBE & FEEDBACK

General Specifications DRV DRV-Exm DRV-Exd

2/2 directional seat valve, direct operated with solenoid actuation

Proportional pressure reducing cartridges type LIRCZO normally closed, ISO 7368 sizes from 16 to 40

VER03MP CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED VER03MP - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED

VS6M - SOLENOID OPERATED DIRECTIONAL VALVES

Ex-proof proportional valves multicertification ATEX, IECEx, EAC

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

VED05MG CONTINENTAL HYDRAULICS PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE VED05MG - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve

VSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES

Pressure reducing valve, direct operated

VSD*S -MONITORED DIRECTIONAL CONTROL VALVES

SOLENOID VALVES no voltage release (lever type) manual reset construction 1/4 to 1/2

VSD05M-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVES

Check valve, pilot operated

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN>

INSTRUCTION MANUAL (ATEX / IECEx)

VED*MJ - PILOTED PROPORTIONAL DIRECTION CONTROL VALVES WITH OBE & FEEDBACK

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Ex m Solenoid Operator Type 0519

Pilot-Operated Directional Control Valves Series D3 - D11

Proportional pressure control cartridges with integral pressure transducer

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

3/2 and 4/2 directional seat valves with solenoid actuation

Transcription:

www.atos.com Table TE137-1/E Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification TEX, IECEx, EC or CULUS certification Ex-proof solenoid Valve body Solenoid plunger Spool / poppet Spring Manual override pin Cable entrance Standard solenoid DHXW4-07*/M DHOXW-* New line of directional solenoid valves with stainless steel internal parts for application with water base fluids. Features: These valves are made by selected inoxidizable materials for internal parts to withstand applications with water base fluids or just pure water. External components are derived from standard valves. Two basic versions are available, poppet type, 3-way leak free (suitable for accumulator systems) or spool type, 4- way on-off valves. The valves are available with standard or ex-proof solenoids, these last certified according to: - Multicertification TEX, IECEx, EC - CULUS certification ISO standard subplate mounting. Options for ex-proof version: Handwheel manual override (option /V) Manual reset (option /R) for safety applications Horizontal cable entrance. Common pplications: Steel plants, die casting, foundry. 1 STINLESS STEEL VLVES: MIN DT Code (1) DHOXW DLOHXW DLOHMXW DLOPXW DHXW6 DHXW4 DLHXW6 DLHXW4 DLHMXW6 DLHMXW4 DLPXW6 Voltages Multicertification Description ISO size DC C T class (2) Input 50/60Hz Standard Option /7 Power 4 way, spool type piloted solenoid valve 4 way, spool type piloted solenoid valve no no 24 110 220 24 48 110 220 24 110 230 T6 T6 T6 T6 32 W (only for and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W 8 W 25 W 8W 25 W 8 W T class (2) T6, T5 T6, T5 T6, T5 T6, T5 CULUS Input Power W 33 W W 33 W W 33 W W Max flow l/min 60 25 220 60 70 10 25 30 220 Dp Max pressure (at max flow) bar (3) bar see diagram at section 8 350 350 350 350 250 Notes: 1) XW6 and XW4 versions differ only for the coil power (see Input Power) 2) Solenoid temperature class, see section 3 3) Max pressure on T port = 110 bar Valves are provided by HNR seals, which allow min ambient temperature down to -40 C (max oil viscosity = 380 cst). The min ambient temperature for valves with PE option (FPM seals) is -20 C. Max ambient temperature without solenoids is 70 C TE137

2 MTERILS SPECIFICTION Valve type DHXW DHOXW DLOHXW DLOHMXW DLHXW DLHMXW DLOPXW DLPXW solenoid housing Cast iron Cast iron valve body ISI 316L ISI 630 internal parts + Cast iron ISI 316L ISI 316L, 420, 440C, 430F ISI 302 HNR (buna) FPM (viton) ISI 316L, 420, 440C, 430F ISI 316L, 420, 440C, 430F spring ISI 302 ISI 302 std HNR (buna) HNR (buna) seals /PE FPM (viton) FPM (viton) 3 EX-PROOF SOLENOIDS: MIN DT VLVE TYPE DHXW6 DLHXW6 DLHMXW6 DLHPXW6 DHXW4 DLHXW4 DLHMXW4 Solenoid code Cable entrance and electrical wiring Metod of protection Multicertification CULUS Multicertification Temperature class mbient temperature OXW/WP Notes: (1) 48DC and 5DC only for Multicertification For alternating current supply a rectifier bridge is integrated in the solenoid Ex d OKXW/WP CULUS OXWUL/WP OKXWUL/WP Voltage VDC ±10% DC, 24DC, 48DC (1), 110DC, 5DC (1), 220DC code VC 50/60 Hz ±10% C, 24C, 110-0C, 230-240C Power Multicertification 8W 25W consumption CULUS W 33W Coil insulation Class H Protection degree IP /67 ccording to IEC 144 when correctly coupled with the relevant cable gland, see table K600 Duty factor 100% Mechanical construction Multicertification Flame proof housing classified Ex d, according to EN 60079-0: 20, EN 6079-1: 2007 CULUS Flame proof housing classified according to UL 03 and UL429, CS 22.2 n 30-1986 and CS 22.2 n 139-13 Internal terminal board for cable connection threaded connection for cable entrance vertical (standard) or Horizontal (option /O) Temperature class mbient temperature T6 ( 85 C) ( 135 C) ( 135 C) ( 200 C) -40 +45 C -40 +70 C -40 +40 C -40 +70 C T6 ( 85 C) T5 ( 100 C) ( 200 C) -40 +70 C -40 +55 C -40 +70 C 4 MIN CHRCTERISTICS, SELS ND HYDRULIC FLUIDS - for other fluids not included in below table, consult our technical office ssembly position / location ny position for all valves Subplate surface finishing Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101) Seals, recommended fluid temperature HNR seals (standard) = -40 C +60 C, with HFC hydraulic fluids = -40 C +50 C FKM seals (/PE option) = -20 C +80 C Recommended viscosity 15 100 mm 2 /s - max allowed range 2.8 500 mm 2 /s Fluid contamination class ISO 44 class 21/19/16 NS 1638 class 10, in line filters of 25 mm (b10 _>75 recommended) Hydraulic fluid Suitable seals type Classification Ref. Standard Mineral oils HNR, FKM HL, HLP, HLPD, HVLP, HVLPD DIN 51524 Flame resistant without water FKM HFDU, HFDR Flame resistant with water HNR HFC ISO 922

5 CULUS CERTIFICTION CULUS marking EXMPLE OF NMEPLTE MRKING Class I Division 1 Groups C&D Groups II&II T6/T5 = Equipment for famable gas and vapours = Possibility of explosive atmosphere during normal functioning = tmosphere containing flamable gas = Gas group = Temperature class of solenoid surface referred to +55 C / +70 C ambient temperature Marking according to UL Directive Notified body and certificate number 6 MULTICERTIFICTION TEX, IECEx, EC In the following are resumed the valves marking according to multicertifications for Group II GROUP II, TEX, marking II 2 G = Solenoid for surface plants with gas and vapors environment, category 2, suitable for zone 1 and zone 2 Ex d = Explosion-proof equipment II C = Equipment of group IIC suitable for substances (gas) of group IIC T6/ = Solenoid temperature class (maximum surface temperature) Gb = Equipment protection level, high level protection for explosive Gas atmospheres = Mark of conformity to the applicable European directives II 2 D = Solenoid for surface plants with dust environment, category 2, suitable for zone 21 and zone 22 Ex d = Explosion-proof equipment III C = Suitable for conductive dust (applicable also III and/or III) IP/67 = Protection degree T85/T135 = Maximum surface temperature (Dust) Db = Equipment protection level, high level protection for explosive Dust atmospheres = Mark of conformity to the 94/9/CE directive and to the technical norms GROUP II, IECEx marking Ex d = Explosion-proof equipment IIC = Equipment of group IIC suitable for substances (gas) of group IIC T6/ = Solenoid temperature classes (Gas) Gb = Equipment protection level, high level protection for explosive Gas atmospheres Ex tb = Equipment protection by enclosure tb IIIC = Suitable for conductive dust (applicable also III and/or III) T85 C/T135 C = Maximum surface temperature (Dust) Db = Equipment protection level, high level protection for explosive Dust atmospheres IP/67 = Protection degree tex notified body and certificate number Marking according to TEX Directive IECEx notified body and certificate number Marking according to IECEx Directive Russian notified body and certificate number Marking according to TEX Directive EXMPLE OF NMEPLTE MRKING 6.1 EC marking EC certification acknowledges the whole TEX Directive 94/9/EC. This certification is available only for gas environment (not for dust). II 2 G = Solenoid for surface plants with gas and vapors environment, category 2, suitable for zone 1 and zone 2 Ex d = Explosion-proof equipment II C = Equipment of group IIC suitable for substances (gas) of group IIC T6/ = Solenoid temperature class (maximum surface temperature) = Mark of conformity to the 94/9/CE directive and to the technical norms

7 SPOOL TYPE DIRECTIONL SOLENOID VLVES: MODEL CODE DH XW 4 * - 0 63 1/2 - M / V 24DC ** Spool type - direct = ex-proof solenoids O = standard solenoids /* Seals material, see section 4: - = NR PE = FKM Stainless steel execution for internal parts Series number Temperature class, see sect. 1 (only for DH) 4 = 6 = T6 Certification type - omit for Multicertification /UL = CULUS with 1 m cable lenght, factory wired Voltage code - see section 1 Options: = solenoid at side of port Options (only for DH): V = with handweel manual override O = horizontal cable entrance Size: 0 = Solenoid threated connection (only for DH): M = M20x1,5 UNI-4535 (6H/6g) Valve configuration, see section 7.1 NPT = 1/2 NPT NSI/SME.1 (tapered) only for /UL 61, 63, 71, 75 (configurations 63 and 75 are available only with spool type 1/2) Spool type, see section 7.1 7.1 Hydraulic configuration Configuration for DH Spools for DH Configuration for DH Spools for DH -1* 1 0 0 1 0 2-3* 1 2 1/2 1 0 2-1*/ 1 0 2 1 2 3-3*/ 1 0 2-071* 6-075 1 2 7 8 POPPET TYPE LEK FREE DIRECTIONL SOLENOID VLVES: MODEL CODE Standard solenoid DLOH = direct ( l/min) DLOHM = direct (25 l/min) DLOP = electro-hydraulically piloted Ex-proof solenoid DLH = direct (10 l/min) DLHM = direct (25 l/min) DLP = electro-hydraulically piloted Stainless steel execution for internal parts Temperature class, see sect. 1 (only for ex-proof solenoids) 4 = (for DLH and DLHM) 6 = T6 (for all ex-proof models) Certification type - omit for Multicertification /UL = CULUS with 1 m cable lenght, factory wired 3 = three way DLOH XW 6 * - 3 - M / V 24DC ** /* Valve configuration, see section 8.1 = to T in rest position Series number Voltage code - see section 1 Options (only for ex-proof solenoids): R = with solenoid manual reset V = with handweel manual override O = Horizontal cable entrance Only for DLPXW D = internal drain E = external pilot pressure Seals material, see section 4: - = NR PE = FKM Solenoid threated connection (only for ex-proof solenoids): M = M20x1,5 UNI-4535 (6H/6g) NPT = 1/2 NPT NSI/SME.1 (tapered) only for /UL C = P to in rest position 8.1 Hydraulic configuration DLHXW*-3/M/V DLHXW*-3C/M DLHMXW*-3/M-O/R DLHMXW*-3C/M-O P T P T P T P T DLPXW6-3/M DLPXW6-3C/M P T X Y P T X Y TE137

9 Q/Dp DIGRMS (based on mineral oil ISO VG at 50 C) DHOXW, DHXW4 DLOHXW, DLHXW DLOHMXW, DLHMXW valve pressure drop [bar] valve pressure drop [bar] C valve pressure drop [bar] F E D DLOPXW, DLPXW DHOXW, DHXW -T P- Flow direction P P T T PT Spool type 0 1, 1/2 3 6 Flow direction P Valve type (P ) DLOHXW-3 C DLOHXW-3C DLOHMXW-3 F T ( T) E 7 DLOHMXW-3C E D 10 OPERTING LIMITS OF ON/OFF DIRECTIONL CONTROLS (based on mineral oil ISO VG at 50 C) The diagram have been obtained with warm solenoids and power supply at lowest value (Vnom -10%). For DHXW valves the curves refer to application with symmetrical flow through the valve (i.e. P and T). In case of asymmetric flow the operating limits must be reduced. DHOXW, DHXW4 DHXW6-O DLOHXW, DLHXW4 S M S M 3 3C M = Spools 0, 1 S = Spools 1/2, 3, 6, 7 M = Spools 0, 1 S = Spools 1/2, 3, 6, 7 DLOHMXW, DLHMXW DLHXW6 DLOPXW, DLPXW6 3 3C minimum piloting pressure Piloting pressure [bar] DLOHMXW-3 and DLOKXW4-3-O DLOHMXW-3C and DLOKXW4-3C-O DLOHMXW6-3(3C)-O 10.1 Internal leakages internal leakage of DLOHXW, DLOHMXW, DLOPXW: less than 5 drops/min (0,36 cm 3 /min) at max pressure. 10.2 Piloting pressure (DLOPXW) - max piloting pressure = bar - min piloting pressure = see diagram

11 CLE GLNDS ND WIRING 11.1 Cable glands - only for Multicertification Cable glands with threaded connections M20x1,5 for standard or armoured cables have to be ordered separately, see tech. table K600 11.2 Ex proof solenoid wiring Multicertification CULUS certification CH 3 n 4 M4x20 locking torque 4Nm CH 3 M4 locking torque 4Nm Standard version Option /O Standard version Option /O cover with threaded connection for vertical cable gland fitting cover with threaded connection for horizontal cable gland fitting terminal board for cables wiring screw terminal for additional equipotential grounding standard manual override 1 = Coil 2 = GND 3 = Coil PC 3 poles terminal board suitable for wires cross sections up to 2,5 mm 2 (max WG14) Power supply: section of coil connection wires = 2,5 mm 2 Grounding: section of internal ground wire = 2,5 mm 2 section of external ground wire = 4 mm 2 Wiring specifications Power supply: section of coil connection wires = 2,5 mm 2 Grounding: section of internal ground wire = 2,5 mm 2 The additional equipotential grounding can be also performed by the user on the external facility provided on the solenoid case. Section of external ground wire = 4 mm 2 cover with threaded connection for vertical cable gland fitting cover with threaded connection for horizontal cable gland fitting terminal board for cables wiring standard manual override 1 = Coil + 2 = GND 3 = Coil - PC 3 poles terminal board suitable for wires cross sections up to 2,5 mm 2 (max WG14) (2) = alternative GND screw terminal connected to solenoid housing Cable Specification: Power supply and transducer cables have to comply with following characteristics Suitable for use in Class I Division 1, Gas Groups C rmored Marine Shipboard Cable which meets UL 1309 Tinned Stranded Copper Conductors ronze braided armor Overall impervious sheath over the armor ny Listed (UVZ/ UVZ7) Marine Shipboard Cable rated 300 V min, 15 min. 3C 2,5 mm 2 (14 WG) having a suitable service temperature range of at least -25 C to +110 C ( /T Models require a temperature range from -40 C to +110 C) For Class I wiring the 3C 1,5 mm 2 WG 16 cable size is admitted only if a fuse lower than 10 is connected to the load side of the solenoid wiring. Note: a Loctite sealant type 545, should be used on the cable gland entry threads 11.3 Cable temperature The cable must be suitable for the working temperature as specified in the safety instructions delivered with the first supply of the products. For Multicertification Max ambient temperature [ C] Temperature class Surface temperature [ C] Cable temperature 45 C T6 85 C not prescribed 70 C 135 C 90 C For culus Max ambient temperature [ C] Temperature class Surface temperature [ C] Cable temperature 55 C T6 85 C 100 C 70 C T5 100 C 100 C TE137

INSTLLTION DIMENSIONS OF DHOXW [mm] ISO 4401: 2005 Mounting surface: 4401-03-02-0-05 4 socket head screws M5x50 class.9 Tightening torque = 8 Nm Seals: 4 OR 108 Ports P,,,T: Ø = 7.5 mm (max). P = PRESSURE PORT, = USE PORT T = TNK PORT For the max pressures on ports, see section 4 DHOXW- DHOXW-07 Mass: 1,9 kg Mass: 2,6 kg Overall dimensions refer to valves with connectors type 6 13 INSTLLTION DIMENSIONS OF DLOHMXW [mm] DLOHMXW-3* ISO 4401: 2005 Mounting surface: 4401-03-02-0-05 4 socket head screws M5x50 class.9 Tightening torque = 8 Nm Seals: 4 OR 108 Ports P,,, T: Ø = 7,5 mm (max) DLOHMXW-3C DLOHMXW-3 P = PRESSURE PORT = USE PORT = CLOSED T = TNK PORT Mass: 1,6 Kg Mass: 1,6 Kg Overall dimensions refer to valves with connectors type 6 14 INSTLLTION DIMENSIONS OF DLOPXW [mm] Mounting surface of DLOPXW is not ISO standard 4 socket head screws M10x70-4-70 Tightening torque = 40 Nm Seals: 3 OR 3081; 2 OR 108 Ports P,,T: Ø = 16 mm (max) Ports X, Y: Ø = 7 mm (max) DLOPXW-3* Mass: 7 kg Overall dimensions refer to valves with connectors type 6

15 INSTLLTION DIMENSIONS OF EX-PROOF DHXW [mm] horizontal cable entrance option /O 115 31.75 0.75 ø5.5 40.5 30.2.7 5.1 15.5 25.9 31 ISO 4401: 2005 Mounting surface: 4401-03-02-0-05 4 socket head screws M5x50-4-70 Tightening torque = 5,5 Nm Seals: 4 OR 108 Ports P,,,T: Ø = 7.5 mm (max). P = PRESSURE PORT, = USE PORT T = TNK PORT DHXW**-* DHXW**-*/V 111 Mass: 2,9 kg 11 150 Mass: 3 kg 11 DHXW**-07* DHXW**-07*/V 111 Mass: 4,6 kg 111 150 Mass: 4,8 kg 150 16 INSTLLTION DIMENSIONS OF EX-PROOF DLHXW ND DLHMXW [mm] horizontal cable entrance option /O 113.5 31.75 0.75 ø5.5 40.5 30.2.7 5.1 15.5 25.9 31 ISO 4401: 2005 Mounting surface: 4401-03-02-0-05 4 socket head screws M5x50-4-70 Tightening torque = 5,5 Nm Seals: 4 OR 108 Ports P,,,T: Ø = 7.5 mm (max). P = PRESSURE PORT, = USE PORT T = TNK PORT DLHXW*-3/M/V DLHXW*-3C/M 150 Mass: 3 kg 111 Mass: 2,9 kg DLHMXW*-3/M/R DLHMXW*-3C/M 99 156.5 Mass: 3,8 kg.5 111 Mass: 2,9 kg TE137

17 INSTLLTION DIMENSIONS OF EX-PROOF DLPXW [mm] Mounting surface DLPX(S)6 and DLPX(S) not ISO standard 4 socket head screws M10x70-4-70 Tightening torque = 40 Nm Seals: 3 OR 3081; 2 OR 108 Ports P,,T: Ø = 16 mm (max) Ports X, Y: Ø = 7 mm (max) 50 25 9 T 105 P 35 40 61 80.5 70 14 option /O 115 181 DLPXW6-3/M DLPXW6-3C/M (dotted line) option /V 153 165 (culus) 153 165 (culus) 85 105 25 215 70 5 05/17