Temperature Sensors. Information Sheet

Similar documents
REQUIRED TOOLS 3 mm screw driver Wrench Crosstip screwdriver

Temperature sensors. and accessories for heat and cooling measurement points. Applications. Benefits. Features

Fluxi 2000/TZ Turbine Gas Meter

Delta Commercial & Industrial Rotary Meter

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

SSV SL-022 Safety Shut-off Valve

zelsius Installation and operating manual All that counts EnergyMetering

Delta Commercial & Industrial Rotary Meter

zelsius Installation and operating manual All that counts. EnergyMetering

Heat Meter Integrator

Measuring capsule heat meter G54 / G55

COMPONENTS FOR SOLAR THERMAL SYSTEMS

LEAKAGE CLASS ACHIEVED? Wöhler DP 700 LEAKAGE TEST ON VENTILATION SYSTEMS AND COMPONENTS. The Measure of Technology GRAPHIC COLOR DISPLAY GRAPHIC

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Heating and Cooling Catalog

Installation & Maintenance Instructions MULTICAL 403. Supplied by. .com. Call us on +44 (0)

WZMC-402 Ultrasonic Apartment Energy Meters

SITRANS P measuring instruments for pressure

Conductivity Measurement CLM 280

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-USA

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG

Compact System NRGS 11-2 NRGS Original Installation Instructions English

A and B Series Sensors for Humidity and Temperature for industrial applications from C and up to 25 bar

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Manual motor starter MS132

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

product catalogue Q116 ISO 9001:2008 certified

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

High-Flow. Type TK16 H 2. WEH - We Engineer Hightech WEH H 2. Fuelling Nozzle with Data Interface DATA SHEET

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Product specification

CONA -control Monitoring system for steam traps

A and B Series Sensors for Humidity and Temperature for industrial applications from C and up to 25 bar

Operating manual. ba55321de LRD Conductivity measuring cell to be installed in pipelines. ba55321de01 12/00

Product specification

HLX771/772. Inline Flowmeter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) Typical Applications

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

N086, N186, N786. Pressure retaining valve, Plastic

JUMO MIDAS S05 Pressure transmitter Type

PPU, PHU Piston Pumps for progressive grease and oil systems, pneumatically or hydraulically actuated

Fluxi 2000/TZ Turbine Gas Meter

Swivel Joints Rotary Unions

Flow measurement FlexFlow PF20H Hygienic flow sensor

product catalogue Q215 ISO 9001:2008 certified

MULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Differential Pressure and Flow meters Accessories for the Media Series

Rosemount Multipoint Thermocouple and RTD Profiling Sensors

Thermowell for temperature sensors omnigrad M TW 13

Differential Pressure Sensors

RTD Temperature Sensor omnigrad T -TR 470

ALLWEILER. Block Macerators Series ABM Designs S and I. Design I with controller and seal water unit

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

Electromagnetic Flow Monitor magphant

BUTTERFLY VALVES + NA ELECTRIC ACTUATOR

gskin Instruction Manual gskin Heat Flux Sensors for greenteg AG Technoparkstrasse 1 greenteg.com

Tina 4A Connection block

PRODUCT SPECIFICATION. Foot Switches. Series.

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

For high-viscosity oils and fluid grease of NLGI grades 000, 00 For use in SKF MonoFlex single-line centralized lubrication systems

A and B Series Sensors for Humidity and Temperature for industrial applications from C and up to 25 bar

CAV-S Mechanical constant volume fl ow controller, steel

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

Product specification

Grey cast iron Fig. 600 Page 2. Forged steel High temperature steel Stainless steel Fig. 600/601 (Y) DN15-25 Page 4 DN40-50 Page 6

Temperature Sensors. Description. Specification

FL series position switches

MBN Multistage Ring Section Pumps

Technical Data and Operating Instructions Thermal Dry Running Protection ATLS-T1

DatA sheet. D-2011/05/ Date: 02/2013. Type TK10 CNG. CNG Fuelling Nozzle. for cars FUTURE. TECHNOLOGY. TODAY.

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

VALVES WITH SA03 ELECTRIC ACTUATOR

Solutions in Rail Heating Systems. Rail Heating Proposal. Innovations in heat tracing

NTC Thermistors, 2-Point Radial Leaded, Automotive Grade

Differential-Pressure Flow Meter

Manual motor starter MS132

mass flowmeter for compressed air

Gas-actuated thermometer with switch contacts Model 73, stainless steel version

SENSOR MUT2200EL. Electromagnetic flowmeter. The electromagnetic flowmeter for all applications DS100-6-ENG

Manual motor starter MS132

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0

aquaconcept Product features Customer benefits

Pressure transmitter UNIVERSAL CA

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

Service - Safety Manual

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

COMPONENTS FOR SOLAR THERMAL SYSTEMS

Operating Instructions TF04

OPERATORS MANUAL FOR USE WITH MAGNETIC/HEATED STIRRER MG200

2/2-way Globe Valve for media up to +180 C, DN

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Hello, I am the new Zelsius C5 heat meter. The new generation of ultrasonic heat and cooling meters for precise energy consumption measurement.

High temperature steel Fig. 600 Page 8. High temperature steel Fig. 600 Page 10. High temperature steel Fig. 600 Page 12

V-MV Variables Mooney Viskosimeter. Testing instruments. Laboratory Equipment. Software systems. Service. Consulting

Transcription:

Temperature Sensors Information Sheet Itron temperature sensors are built in highest quality for various applications. A wide selection of direct and pocket installed sensors are a great complement of our thermal energy meters. All temperature sensors are delivered paired, verified by the MID initial calibration. Furthermore, all sensors meet the requirements of DIN EN 1434. CHARACTERISTICS» Your benefi ts Highest accuracy Smallest measuring errors Great response behavior Exact instantaneous values Different versions Always the right solution» Properties Temperature sensors Pt 100 and Pt 500 Paired acc. EN1434 Standard DIN EN 1434 and AGFW CE conform (MID)» Field of applications Direct installation and pocket installation Temperature measurement in closedloop pipe systems of building service areas to measure cooling- and heating energy Temperature measurement for energy measurements for district heating and cooling INFORMATION knowledge to shape your future

TEMPERATURE SENSORS OVERVIEW Direct Installation TDF 27 TDF 38 TDF 85/120/210 TDF 91/146 Measuring resistance Pt 100 / Pt 500 Pt 100 Pt 100 Pt 100 Standard compliance EN 1434 / EN 60751 EN 1434 / EN 60751 EN 1434 / EN 60751 EN 1434 / EN 60751 Connection 2-wire 2-wire 2-/4-wire 2-wire Temperature range 0 to 150 C 0 to 150 C 0 to 180 C 0 to 180 C Temperature difference 3 to 150 K 3 to 150 K 3 to 180 K 3 to 180 K Responce time T0,5 2 s 2 s 6 s 6 s Environmental temperature 0 to 70 C 0 to 70 C 0 to 70 C 0 to 70 C Sleeve diameter 5,4 / 3,6 mm 5,4 / 3,3 mm 8 / 6 mm 6 mm Fitting length 27,5 mm 38 mm 85 / 120 / 210 mm 91 / 146 mm Connection thread M10x1 M10x1 G 1/2 G 1/4 Connection cable Silicone Silicone Silicone Silicone Cable lengths 1,75 / 2,5 / 5* / 10* m 2,5 m Head Type 2,5 m Wire cross section 2x0,34 mm² 2x0,34 mm² 2x/4x0,75 mm² 2x0,34 mm² Protection class IP 65 IP 65 IP 65 IP 65 * only for Pt 500 2

TEMPERATURE SENSOR FOR DIRECT INSTALLATION TDF 27 Technical Data Measuring resistance Pt 100 / Pt 500 Standard compliance EN 1434 / EN 60751 Connection 2-wire Temperature range 0 to 150 C Temperature difference 3 to 150 K Response behavior T0,5 2 s Environmental temperature 0 to 70 C Sleeve diameter 5,4 stepped down to 3,6 mm Fitting length 27,5 mm Connection thread M10x1 Connection cable Silicone Cable lengths 1,75 / 2,5 / 5* / 10* m Wire cross section 2x0,34 mm² Protection class IP 65 * only for Pt 500 Items Type Cable length Article-No. TDF 27 1,75 m Pt 100 2961830006 TDF 27 2,50 m Pt 100 2961831306 TDF 27 1,75 m Pt 500 2961837006 TDF 27 5,00 m Pt 500 2961837506 TDF 27 10,0 m Pt 500 2961837706 Adapters for direct sensors acc. EN1434 Article-No. M10x1 G3/8 M10 / 3/8 IG 4825 M10x1 G½ M10 / ½ IG 5239 M10x1 screw-in fi tting M10 / M10 0930 4825 5239 0930 Accessories Ball valves Article-No. Ball valve ½ -D-complete ½ IG 10195 Ball valve ¾ -D-complete ¾ IG 2671 Ball valve 1 -D-complete 1 IG 4795 Technical Data ball valves Temperature range -20 to 150 C Maximum pressure 16 bar (150 C) 25 bar (110 C) 10195 2671 4795 3

TEMPERATURE SENSOR FOR DIRECT INSTALLATION TDF 38 Technical Data Measuring resistance Pt 100 Standard compliance EN 1434 / EN 60751 Connection 2-wire Temperature range 0 to 150 C Temperature difference 3 to 150 K Response behavior T0,5 2 s Environmental temperature 0 to 70 C Sleeve diameter 5,4 stepped down to 3,6 mm Fitting length 27,5 mm Connection thread M10x1 Connection cable Silicone Cable lengths 2,5 m Wire cross section 2x0,34 mm² Protection class IP 65 Items Type Cable length PT* Article-No. TDF 38 2,50 m Pt 100 2853831306 *PT500 and other length available on request Adapters for direct sensors acc. EN1434 Article-No. M10x1 G3/8 M10 / 3/8 IG 4825 M10x1 G½ M10 / ½ IG 5239 M10x1 screw-in fi tting M10 / M10 0930 SW24 M10x1 SW 22 M10x1 Ø14 6 5.5 SW14 16.5 17.5 19.5 G3/8 M10x1 4825 5239 0930 G1/2 Accessories Ball valves Article-No. Ball valve 1 ¼ -D-complete 1 ¼ IG 14575 Ball valve 1 ½ -D-complete 1 ½ IG 14573 Technical Data ball valves Temperature range -20 to 150 C Maximum pressure 16 bar (150 C) 25 bar (110 C) 14575 14573 4

TEMPERATURE SENSOR FOR DIRECT INSTALLATION TDF 85 / 120 / 210 Technical Data Measuring resistance Pt 100 Standard compliance EN 1434 / EN 60751 Connection 2-wire 4-wire Temperature range 0 to 180 C Temperature difference 3 to 180 K Response time T0,5 6 s Environmental temperature 0 to 70 C Sleeve diameter 8 stepped down to 6 mm Fitting length 85 / 120 / 210 mm Connection thread G 1/2 Connection cable Silicone Wire cross section 2x/4x0,75 mm² Protection class IP 65 Items Type* PT Article-No. TDF 85 Pt 100 2951513006 TDF 120 Pt 100 2952513006 TDF 210 Pt 100 2953513006 *without connection cable, please see accessoriies for possible connection cables TDF 85 TDF 120 Accessories TDF 210 Welding Sleeve Article-No. AM ½ x44 mm / 45 0649 Connection Cable Cable length 2/4-wire Article-No. 3 m 2-wire 0973 5 m 2-wire 4490 10 m 2-wire 4491 10 m 4-wire 10344 5

COMBINED TEMPERATURE SENSOR TDF 91 / 146 - DIRECT & POCKET INSTALLATION - REPLACES VARIOUS ON MARKET USED TEMPERATURE SENSORS Technical Data Measuring resistance Pt 100 Standard compliance EN 1434 / EN 60751 Connection 2-wire Temperature range 0 to 180 C Temperature difference 3 to 180 K Response time T0,5 6 s Environmental temperature 0 to 70 C Sleeve diameter 6 mm Fitting length 91 / 146 mm Connection thread G 1/4 Connection cable Silicone Cable lengths 2,5 m Wire cross section 2x0,34 mm² Protection class IP 65 Items Type Cable length PT Article-No. TDF 91 2,50 m Pt 100 5524531306 TDF 146 2,50 m Pt 100 5525531306 Accessories Pockets PN Article-No. TH ½" x 91 mm PN 40 11278 TH ½" x 146 mm PN 40 11690 TDF 91 TDF 146 11278 11690 6

Pocket Installation THF 50 THF 105/140/230 THF C105/C140/C230 Measuring resistance Pt 100 / Pt 500 Pt 100 Pt 100 / Pt 500 Fulfi lled regulations EN 1434 / EN 60751 EN 1434 / EN 60751 EN 1434 / EN 60751 Measuring insert 2-wire 2-wire 2-/4-wire Temperature range 0 to 150 C 0 to 150 C 0 to 150 C Temperature difference 3 to 150 K 3 to 150 K 3 to 150 K Response time T0,5 2 s 6 s 6 s Climatic conditions 0 to 70 C 0 to 70 C 0 to 70 C Sleeve diameter 6 mm 6 mm 6 mm Fitting length 50 mm 105 / 140 / 230 mm 105 / 140 / 230 mm Connection thread M10x1 M16x1,5 M16x1,5 Connection cable Silicone Silicone Silicone Cable lengths 1,75 / 2,5 / 5* / 10* m Head Type 2,5 / 5 m Wire cross section 2x0,34 mm² 2x0,34 mm² 2x/4x0,34 mm² Protection class IP 65 IP 65 IP 65 * only for Pt 500 7

TEMPERATURE SENSOR FOR POCKET INSTALLATION THF 50 Technical Data Measuring resistance Pt 100 / Pt 500 Standard compliance EN 1434 / EN 60751 Connection 2-wire Temperature range 0 to 150 C Temperature difference 3 to 150 K Response time T0,5 2 s (installed in pocket 15 s) Environmental temperature 0 to 70 C Sleeve diameter 6 mm Fitting length 50 mm Connection thread M10x1 Connection cable Silicone (Spiral = PUR) Cable lengths 1,75 / 2,5 / 5 / 10 m Wire cross section 2x0,34 mm² (spiral cable 2x0,25 mm²) Protection class IP 65 Maximum pressure PN 25 Items Type Cable length Pt Article-No. THF 50 1,10 m* Pt 100 2960230006 THF 50 1,75 m Pt 100 2960830006 THF 50 2,50 m Pt 100 2960831306 THF 50 1,75 m Pt 500 2960837006 THF 50 5,00 m Pt 500 2960837506 THF 50 10,0 m Pt 500 2960837706 *Spiral cable Accessories Pockets AG PN Article-No. TH M10 x 1 x 28,5 mm M10 AG PN 10 9079 TH 3/8" x 33 mm 3/8" AG PN 10 9080 TH 3/8" x 75 mm 3/8" AG PN 10 9089 TH ¼ x 28 mm ¼ AG PN 10 6811 TH ½" x 33,5 mm ½" AG PN 10 2680 TH ½ x 75 mm ½ AG PN 10 15141 9079 9080 6811 2680 9089 15141 8

TEMPERATURE SENSOR FOR POCKET INSTALLATION THF 50 Welding Sleeves Article-No. AM 3/8" x 12 mm for TH 3/8" x 40 9082 AM 3/8" x 37 mm / 45 for TH 3/8" x 75 9090 9082 9090 Supply pipe pockets PN Article-No. VTTH ½" ½" IG PN 10 13861 VTTH ¾" x 38 mm ¾" IG PN 10 1838 VTTH 1" x 46 mm 1" IG PN 10 9166 13861 1838 9166 9

TEMPERATURE SENSOR FOR POCKET INSTALLATION THF 105 / 140 / 230 Technical Data Measuring resistance Pt 100 Standard compliance EN 1434 / EN 60751 Connection 2-wire Temperature range 0 to 150 C Temperature difference 3 to 150 K Response time T0,5 6s (installed in pocket 12s) Environmental temperature 0 to 70 C Sleeve diameter 6 mm Fitting length 105 / 140 / 230 mm Connection thread M16x1,5 Connection cable Silicone Wire cross section 2x0,75 mm² Protection class IP 65 Items Type* Pt Article-No. THF 105 Pt 100 5520833006 THF 140 Pt 100 5521833006 THF 230 Pt 100 5522833006 *without connection cable, please see accessories for possible connection cables THF 105 THF 140 THF 230 10

TEMPERATURE SENSOR FOR POCKET INSTALLATION THF 105 / 140 / 230 Accessories Connection Cable Cable length 2/4-wire Article-No. 3 m 2-wire 0973 5 m 2-wire 4490 10 m 2-wire 4491 10 m 4-wire 10344 Pockets AG PN Article-No. TH ½" x 85 mm ½ AG PN 25 7265 TH ½" x 120 mm ½" AG PN 25 7266 TH ½" x 210 mm ½" AG PN 40 13802 7265 7266 13802 Welding Sleeves Article-No. AM ½" x 44 mm / 45 0649 44 G1/2 Ø27 45 11

TEMPERATURE SENSOR FOR POCKET INSTALLATION THF C105 / C140 / C230 Technical Data Measuring resistance Pt 100 / Pt 500 Standard compliance EN 1434 / EN 60751 Connection 2-wire 4-wire 0 to 150 C Temperature range 0 to 150 C Temperature difference 3 to 150 K Response time T0,5 6s (installed in pocket 12s) Environmental temperature 0 to 70 C Sleeve diameter 6 mm Fitting length 105 / 140 / 230 mm Connection thread M16x1,5 Connection cable Silicone Cable lengths 2,5 / 5 m Wire cross section 2x/4x0,34 mm² Protection class IP 65 Items Type Cable length* Pt 2/4-wire Article-No. THF-C105 2,50 m Pt 100 2-wire 5530831306 THF-C105 5,00 m Pt 100 4-wire 5530838506 THF-C105 2,50 m Pt 500 2-wire 5529837106 THF-C105 5,00 m Pt 500 4-wire 5529839506 THF-C105 10,00 m Pt 500 2-wire 5529837706 THF-C140 2,50 m Pt 100 2-wire 5531831306 THF-C140 5,00 m Pt 100 4-wire 5531838506 THF-C140 2,50 m Pt 500 2-wire 5531837106 THF-C140 5,00 m Pt 500 4-wire 5531839506 THF-C140 10,00 m Pt 500 2-wire 5531837706 THF-C230 2,50 m Pt 100 2-wire 5532831306 THF-C230 5,00 m Pt 100 4-wire 5532838506 THF-C230 2,50 m Pt 500 2-wire 5532837106 THF-C230 5,00 m Pt 500 4-wire 5532839506 *other cable length on request 12

TEMPERATURE SENSOR FOR POCKET INSTALLATION THF C105 / C140 / C230 Accessories Pockets AG PN Article-No. TH ½" x 85 mm ½ AG PN 25 7265 TH ½" x 120 mm ½" AG PN 25 7266 TH ½" x 210 mm ½" AG PN 40 13802 SW22 SW22 SW27 120 133 12 15 12 15 15 12 G1/2B G1/2B 85 98 G1/2 B R0, 5 Ø8 213 7265 R0, 5 Ø8 7266 Ø10 Ø1 2 13802 Welding Sleeves Article-No. AM ½" x 44 mm / 45 0649 13

MOUNTING OPTIONS FOR TEMPERATURE SENSORS 1 Option 1 Installation in threaded pipe fitting and ball valve» direct installation» probe axis perpendicular to axis of fi tting and in same plane 2 Option 2 Installation in Bend» direct installation» pocket installation» probe axis coincident with pipe axis 3 Option 3 Installation in angled probe» direct installation» pocket installation» temperature sensing element inserted to pipe axis or beyond 4 Option 4 Installation in perpendicular probe» direct installation» pocket installation» probe axis perpendicular to pipe axis and in the same plane RECOMMENDATIONS FOR INSTALLATION OF THE TEMPERATURE SENSORS» Temperature sensors for thermal energy applications are paired according to EN1434 accuracy requirements. In case of change the complete pair must be changed.» One temperature sensor should be installed near to the outlet of the fl ow meter. Flow meters DN15 and 20 offer a measuring point directly integrated in the fl ow meter (downstream position).» Both supply and return temperature sensors should be installed in a similar way to ensure symmetric measurement and therefore best accuracy. Don t mix direct installation with installation in pockets.» In 2-wire measurement the connection cable of both temperature probes must have the same cable length (same wire resistance).» When laying the cables a minimum distance of 50 mm to main power cables and/or sources of electromagnetic interferences should be respected.» In case of strong sources for electromagnetic disturbances (e.g. high power machines and pumps, frequency and power converters, power switches, neon tubes) it s recommended to increase the minimum distance to meter signal cables to 50 cm.» To achieve highest accuracy, the tip of the probes/pockets should reach the center of the pipe. 14

DN AND CORRESPONDING TEMPERATURE SENSOR Type Installation in Termowells/Pockets Direct Installation DN 15 - DN 25 THF 50 with dedicated Accessories DN 32 - DN 40 THF 50 with dedicated Accessories DN 50 - DN 80 THF 105 THF C105 DN 100 - DN 200 THF 140 THF C140 DN 250 - DN 500 THF 230 THF C230 TDF 27 TDF 38 TDF 85 TDF 120 TDF 210 ACCURACY PAIR OF TEMPERATURE SENSORS 4,00% 3,00% 2,00% 1,00% Error in % 0,00% 0 20 40 60 80 100 120 140 160 180 200-1,00% -2,00% -3,00% -4,00% dt (K) 15

INSTALLATION KITS Direct installation Kits Type Article-No. EBS DN15 G¾ x110-d-kh J 2433000106 EBS DN15 G¾ x110-d I 2434000106 EBS DN20 G1 x130-d-kh J 2431000106 EBS DN20 G1 x130-d I 2432000106 EBS DN20 G1 x190-d-kh J 2481000106 EBS DN20 FL 190-D K 2483000106 EBS DN25 G1¼ x150-d-kh O 2426007006 EBS DN25 G1¼ x 260-D-KH O 2426007006 EBS DN25 G1¼ -D-KH N 2436007206 EBS DN25 FL 260-D-KH P 2484007006 EBS DN25 FL-D-KH Q 2436007306 EBS DN32 G1½ x -D-KH N 2437007206 EBS DN40 FL 300-D-KH P 2485007006 EBS DN40 FL-D-KH Q 2438007306 EBS DN40 G2 x 200-D-KH O 2430007006 EBS DN40 G2 -D-KH N 2438007206 EBS DN40 G2 x 300-D-KH O 2427007006 Pocket installation Kits Type Article-No. EBS DN50 FLx270 G 2451000006 EBS DN50-80 H 2463000006 EBS DN50 FLx200 G 2455000006 EBS DN65 FLx200 G 2456000006 EBS DN65 FLx300 G 2452000006 EBS DN80 FLx300 G 2453000006 EBS DN80 FLx225 G 2457000006 EBS DN100 FLx250 G 2458000006 EBS DN100 FLx360 H 2454000006 EBS DN100-200 Tauchh. H 2464000006 Kits G H I J K N O P Q Ball valve with DS measuring entry a a a a a a a 2 x Ball valve a 2 x Ball valve (one with DS measuring entry) a a a a 2 x Pocket and welding piece a a Connector set a a a Distance pipe a a a a a a 16

TEMPERATURE SENSORS INSTALLATION HEATING APPLICATION COOLING APPLICATION Integrator Integrator Supply Hot Sensor Supply Cold Sensor Cold Sensor Flow meter Return Hot Sensor Flow meter Return > Temperature sensors installation best practices for Heating application - Sensor pockets and connected sleeves must be installed head upwards. > Temperature sensors installation best practices for Cooling and Combined applications - To prevent water condensation, sensor pockets and connected sleeves must be installed head downwards. - To prevent rusted terminals, head temperature sensors should be potted with resin. - Never use oil or grease to lubricate pockets. Use silicon instead. 17

Itron is a global technology company. We build solutions that help utilities measure, manage and analyze energy and water. Our broad product portfolio includes electricity, gas, water and thermal energy measurement and control technology; communications systems; software; and professional services. With thousands of employees supporting nearly 8,000 utilities in more than 100 countries, Itron empowers utilities to responsibly and effi ciently manage energy and water resources. Join us in creating a more resourceful world; start here: www.itron.com Although Itron makes every effort to ensure that the content of marketing material is as up-to-date and accurate as possible, Itron cannot be held responsible for the accuracy, completeness or suitability of this material. Itron expressly disclaims any liability for errors or omissions. No responsibility can be taken for this marketing material, neither explicitly nor implicitly or by statute, including, but not restricted to, warranties of any kind regarding non-infringement of rights and claims of third parties or regarding usability and suitability for a certain purpose. Copyright 2014, all rights reserved. P0752 WA-0108.0-EN-04.14 Subject to alterations. Technical status: June 2014 ITRON ALLMESS GMBH Am Voßberg 11 23758 Oldenburg i.h. Germany Tel: +49 (0) 43 61/62 5-0 Fax: +49 (0) 43 61/62 5-250 www. itron.com