Power Challenges Faced by Vehicle Applications

Similar documents
CradlePoint Vehicle Best Practices Installation Guide

OIS21C. Optical smart sensor for hydraulic cylinders. General Description. Features. Applications. Pin Functions. Ordering Information

APPLICATION NOTE. Selecting Inductors for DC-DC Converters and Filters in Automotive Applications INTRODUCTION. 9/13 e/ic1338

Power Quality and Energy Management

Background. Voltage Transient Emission Setup Requirement. Transient Immunity Setup up Requirement Performance Criteria ISO :2004.

AEC Weekend Seminars OV Protection Firewall against failure... OV Protection

European Technical Standard Order (ETSO)

Switching & Protecting Electronics in Battery-Powered Systems

M3-ATX 6-24V Intelligent ATX Power Supply

NO-BREAK KS. Dynamic UPS system PRESENTATION

Stay in power. Battery consumption awareness

Diesel Technology: Electrical and Electronic Systems

Inverter User Manual

PowerCommand 2100 digital generator set control

Tools and Techniques for Ensuring Automotive EMC Performance and Reliability

INSTALLATION INSTRUCTIONS

ELECTRICAL POWER, DIRECT CURRENT, SPACE VEHICLE DESIGN REQUIREMENTS

AUML Varistor Series. Surface Mount Varistors

MGL Avionics EFIS G2 and iefis

Airpax Dimensions, Inc.

A: ENGINE CONTROL MODULE (ECM) I/O SIGNAL FOR MT VEHICLES. Signal (V) Ignition SW ON (Engine OFF) B B B

MULTIPOINT FUEL INJECTION (MPI) <4G9>

Measuring Battery Life on Battery Powered Medical Devices

HARDWIRE VS. WIRELESS FAILSAFE CONTROL SYSTEM. The answer is No.

Automotive Parts. Charging & Starting Systems

(electronic Access & Security Keyless-entry)

Uninterruptible Power System

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Transforming Transforming Advanced transformer control and monitoring with TEC

ATD WATT INVERTER

Owner s Guide. DC TO AC Power Inverter

Unit AE01K Knowledge of Locating and Correcting Simple Electrical Faults in the Automotive Workplace

TECHNICAL DATA SHEET KVA UPS Systemss

3000W POWER INVERTER. User Manual

Handout Activity: HA061

Automotive Electronics/Connectivity/IoT/Smart City Track

200 kva* Noise level (Generator online) Fuel tank size (approx. 5.5 hours autonomy) 1400 liters 308 gallons /370 US gallons

PI1500X Power Inverter User s Manual

5. Engine Control Module (ECM) I/O Signal

Electric Power Marketing Spec Sheet Continuous Power Module CPM250

Common Mistakes in Battery Pack Development (And how to avoid them) By Katherine Mack, Rose Electronics

12V SPLIT CHARGER SYSTEM DIY INSTALLATION KIT INSTRUCTION MANUAL

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Platform Battery Drain Diagnosis Procedure - keywords accessory aftermarket generator low operation regulator volt voltage #PIC3589A - (06/14/2006)

POWER PROFET A simpler solution with integrated protection for switching high-current applications efficiently & reliably

Reach Beyond Traditional Powering Scenarios with New Ultralow I Q Buck-Boost Converters

5. Engine Control Module (ECM) I/O Signal S008526

Chapter 10. Introduction. Electrical Systems. Electrical and Electronic Systems

Diesel generator set QSX15 series engine

Integrated Back-up Battery System

P0750-LR SOLENOID CIRCUIT

Electrical Systems. Introduction

MP-4000 Motor Protection

Model #: APS V DC or 120V AC input; 120V AC output (hardwired) Auto Transfer Switching option for battery backup / UPS operation

LITHIUM / THIONYL CHLORIDE High Power Type ER18505M BRIEF SPECIFICATION

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

USER S MANUAL TUBE SEALER. Model SE700. No. CAT.SE70011Ce

Suppression Products. Overvoltage Suppression Products: Introduction Industrial Varistor Products 173

Sola/Hevi-Duty S3K Series Mini-Tower UPS

TABLE OF CONTENTS. Understanding the Troubleshooting Instructions...2 Signal Light...2 Harness Connections...2 Inspection...2

LITHIUM / THIONYL CHLORIDE Energy Type ER10250 BRIEF SPECIFICATION

A Comparison of Typical UPS Designs in Today s Markets

Relay Retrofit Program Cutting Tool Safety Guide

ATD WATT INVERTER

VariStroke II Electro hydraulic Actuator

Diesel generator set QSX15 series engine

24V TO 13.5V FIXED OUTPUT VOLTAGE CONVERTER

Battery Power Inverters

Elmdene International Ltd

Wired Real Time GPS Installation Instructions

Alternator charging and power distribution system

Error codes Diagnostic plug Read-out Reset Signal Error codes

Testing Lead-acid fire panel batteries

Owner s Manual. PowerVerterDC-to-AC Inverter

Stratomaster Maxi Single

Uninterruptible Power System

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS

HYDRO - 200CX HZ

Diesel generator set QSK23 series engine

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

LITHIUM THIONYL CHLORIDE Computer Back-up Type ER14250-CB BRIEF SPECIFICATION

Potential Electronic Causes of Unintended Acceleration

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

5. Engine Control Module (ECM) I/O Signal

International Telecommunication Union European Diesel Heavy-Duty OBD

Contents. DX Ignition Page 2

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Fuel System Diagnosis

Power Electronics. Motor brake relay GA 9031 ministop

ATOTH-G Series BLDC Motor Controller. User s Manual

DG SYNCHRONIZING &AMF PANEL

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Kart Team. Project Plan: Group 13-22

Battery, Mounting and Cables - Battery and Cables Description and Operation

2003 Explorer/Mountaineer Workshop Manual

Installation Guide for the Header Tank Automatic Fill Relay. (model: HTAF2)

Spark-ignited generator set

Dealing with customer concerns related to electronic throttle bodies By: Bernie Thompson

Transcription:

Power Challenges Faced by Vehicle Applications Written by: Chijen Li, Advantech Corporation, Industrial Mobile Computing Many challenges are faced when designing in vehicle computers: temperature extremes, vibration and shock, RF technologies, and so on. The most important one is related to dirty power. Standard IT products are not suitable for use in vehicles as transient power conditions may damage equipment or even cause explosions. Therefore, the first priority for the in vehicle environment is solving the crucial problems presented by dirty power conditions. The automotive environment is fraught with electrical hazards. These hazards, including electromagnetic interference, electrostatic discharges and other electrical disturbances, are generated by various vehicle sub systems such as ignition, relay contacts, alternator, injectors, and other accessories. These generated hazards can occur directly in the wiring harness in case of conducted hazards, or may affect electronic modules indirectly via induction. The hazards can impact the electronics in two ways either on the data lines or on the power rail wires, depending on the environment. In determining the kinds of factors that will cause problems, the first priority for the in vehicle environment is solving critical problems introduced by dirty power sources. In most present day motorized vehicles, the DC power source is provided by a lead acid rechargeable battery, and that battery is charged by the engine and a generator or alternator. The DC voltage in such an environment is seriously impacted by ignition signals, motor RPMs (speeding up or slowing down), loading devices (audio system, MOD, PND, lamps, horn, etc).

The severest transients result from either a load dump condition or a jump start overvoltage condition. Other transients may also result from relays and solenoids switching on and off, and from fuses opening. Load Dump A load dump condition is caused from a vehicle battery disconnect. When a vehicle battery is disconnected while the alternator is still generating a charging current, the current will raise the voltage to a high level in a short time, causing damage to electronic equipment. The severity of a load dump pulse is determined by the alternator speed and the level of the alternator field excitation at the moment of battery disconnect. Cable corrosion, a poor connection or an intentional battery disconnect might lead to a load dump condition. The image below shows the typical waveform of a load dump pulse and its peak voltage, which could reach 174 volts with duration of 400 milliseconds. Although load dump conditions don t happen often, they are of

concern as their high voltage and huge energy surges are unbearable for most transient protection components, and can result in permanent damage to in vehicle electronic devices. Jump Start A jump start is a condition that occurs when two batteries are connected in series to provide the higher voltage needed to start an engine when it is cranked in cold weather, and the engine oil is very thick. In a nominal 12 volt vehicle system, the jump start voltage would be 24 volts. If the electronic devices are not designed with this in mind, a jump start condition will lead to damage. Cold Crank A cold crank condition occurs when a car s engine is started at cold temperature. Engine oil viscosity is high requiring more current from the battery to start the engine. The large current load will cause battery voltage to drop below 5 volts. The image below illustrates the cold crank waveform. For a general vehicle computing device, especially a PC based one, 5 volt power is a very crucial power rail, and should remain as stable as possible. When faced with cold crank conditions, maintaining a 5 volt power rail becomes a challenge.

Reverse Battery Connection Reverse battery connections are common occurrences in the automotive environment. Designing electronic devices with protection against this condition is a basic requirement. Inductive load Switching Transient Inductive load devices are widely used in the automobile environment for such things as warmup devices, air conditioners, wipers, sprayers, electrical fans, power doors and windows, and so on. These devices will generate switching transients on the power rail while they are operating. The type of transient can range from 200 to +200 volts, in hundreds of milliseconds, and exceeds the bearable voltage levels for general electronic components. Transient voltage can cause severe damage and failure of electrical devices.

Low Power Consumption During Standby or Power Off For electronic devices that are connected to a vehicle battery and drain power directly, ensuring that there is enough power in reserve to start the engine is important. In some cases, the user will operate the electronic devices while the vehicle engine is shut off, and they will consume power without a vehicle charge. If no criterion exists for protection in this circumstance, the vehicle battery will discharge completely. Electronic devices can even consume power while in standby or shut off. To avoid battery discharge, the standby and the quiescent current of electronic devices must be kept as low as possible. When facing the problems mentioned above, it is apparent that in vehicle, electronic device design must include solutions to counteract specific power problems that can occur in an automotive environment. Transient Protection The first solution is transient protection, designed to handle load dump, inductive load switching, jump start conditions, and so on. The transient protection circuits should protect electronic devices from over voltage spikes, and maintain stable power output, to keep the system working even when a transient condition occurs. Power Noise Filtering The switching noise from devices on a vehicle s main power rail might be too high even after it is regulated by a DC DC convertor. This might cause an audible hum in audio output, video or display interference, or even lead to a malfunction of the electronic device. For in vehicle signage, surveillance, or infotainment applications, this is a critical issue. Power noise frequency ranges are different for different kinds of vehicles, and from different power sources.

Wide Range DC Input Vehicle power systems supply different voltages with 12 volt, 24 volt and 48 volt being the most common. To ease the installation of in vehicle applications, a wide input range is necessary. This not only reduces risk from installation mistakes, but also improves resistance against cold crank conditions, jump starts, and load dump conditions. Vehicle Power Management Since electronic devices will drain power from the vehicle battery directly, ensuring battery power is enough to start the engine is a top priority. In the real world, electronic devices might hang or malfunction due to unforeseen conditions. Operating system halts, required responses from application programs or outright failures, will leave a device powered on, continuously consuming power until the battery is complete discharged. This is one of the most critical conditions in which an in vehicle device can cause trouble resulting in a huge loss of time and money. Vehicle power management (VPM) systems must be included to manage the working status of electronic devices to respond to user events (like a change in ignition status) or application programs/operating system activities. The diagram below illustrates how VPM system works.

Vehicle Power Management (VPM) Initial System is OFF Count down to 0 Ignition ON Power Button is Pressed ON_DELAY LOW_HARD_DELAY Count down to 0 Countdown to 0 Count down to 0 System is ON Car_batt_Vol < Batt_Threshold Car_batt_Vol > Batt_Threshold LOW_DELAY Ignition ON Ignition OFF OFF_EVENT_DELAY Count down to 0 HARD_OFF_DELAY

Certifications Certification standards have been developed to ensure the power design of electronic devices is robust enough to pass real world trials for different kinds of applications. These standards have strictly defined the test methodologies that simulate the possible hazards in automotive environments. Below are some of the most common certification standards: emark: A mark of consistency, governed by European Union Directives for conformity of vehicles and vehicle components. An emark indicates conformity to these standards and directives. ISO 7637 2: Road Vehicles A standard test mechanism to measure electrical disturbances from conduction and coupling; Part 2, is concerned with electrical transient conduction along supply lines on vehicles with a nominal 12 volt or 24 volt supply. The second edition is dated 2004. SAE J1455: Recommended environmental practices for electronic equipment design in heavyduty vehicle applications. SAE J1113: Electromagnetic susceptibility measurement procedures for vehicle components (aircraft excluded).

Advantech Solution for Vehicle Power Management Advantech has implemented a complete solution of vehicle power management on TREK series products; this solution is robust again the severe automotive environment and it also passes the certifications mentioned above. The diagram below illustrates the architecture of this VPM solution. The image below shows a real case in TREK products.

Advantech Offers Solutions Advantech industrial mobile computing solutions provide a wide range of products for a variety of vertical markets. Advantech offers integrated solutions for all aspects of industrial mobile computing: systems that work under a wide range of temperatures; certified power systems; x86 and RISC based architectures; a full suite of RF protocols; standardized vehicle diagnostic tools; rich I/O connectors; vibration and shock resistance; and a comprehensive software developer kit to facilitate application development, speeding up time to market for system integrators, and helping reduce costs. For more information, visit www.advantech.com