Eaton Heavy Duty Hydrostatic Transmissions

Similar documents
Eaton Medium Duty Piston Pump. Repair Information. Model Variable Displacement Piston Pump

Eaton Medium Duty Piston Pump. Repair Information. Model Variable Displacement Piston Pump

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

Eaton Hydraulic Motor. Repair Information. 30 Series. July, 1996

Eaton Medium Duty Piston Pump. Repair Information. Model 72400

Eaton. Revised April, Directional Control Valves. Model 30540, 15 GPM Directional Control Valves. We Manufacture. Solutions

Eaton Hydraulic Motor. Repair Information. 45 Series. July, 1996

Char-Lynn Power Steering. Parts Information. 217 Series and 227 Series OUT OUT. November, Series (Gerotor Unit) 227 Series (Geroler Unit)

Eaton Hydraulic Motor. Repair Information. VIS 45 Series Two Speed Bearingless -001

Eaton. Repair Information Tandem. Model and 70344, 40.6 cm 3 /r [2.48 in 3 /r] Displacement Manually Variable Displacement Piston Pump

Eaton Inline Self-Level Valve

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Char-Lynn Hydraulic Motors: h y d r a u l i c s

Char-Lynn Power Steering. Parts Information. 110, 230, and 450 Series. July, 1999

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Char-Lynn Hydraulic Motors. h y d r a u l i c s. General Purpose Motors A Series

Eaton Hydraulic Motor. Repair Information. Series VIS 45. January, 2000

XCEL80 Steering Control Units

Char-Lynn HP 30 Motor

RE (Remote Electric) Control

Eaton Hydrostatic Transaxle. Parts Information. Transaxle Series 751. May, 1999

No EN-0800 (Replaces ) Eaton. Medium Duty Piston Pump. Repair Information. Model Servo Controlled Piston Pump v-04

Char-Lynn Hydraulic Motor. Parts Information. R Series General Purpose Geroler Motor January, 1995

Char-Lynn Steering Control Unit. Repair Information

EATON 751, 781 HYDROSATIC TRANSAXLE

Eaton Hydrostatic Variable Motors. Repair Information

VIS Standard and Wheel Motors 45 Series Parts and Repair Information -005

Vickers Counterbalance Valve. CB Series Mainfold Mounting 315 Bar SAE Flange Mounting L/min Subplate Mounting

Eaton. Revised June, Heavy Duty Hydrostatic Transmissions. l r. Models 33 through 76 Hydrostatic Transmissions. We Manufacture.

Global Gear Products. Brochure. SAE A-Aluminum (Group 2)

s Eaton Light Duty Hydrostatic h y Hydrostatic Transmissions Models 6, 7, and 11 Ball Piston Pumps Models 7 and 11 We Manufacture Solutions

Mobile Valves Proportional - Load Sensing

Fixed Displacement Swing Drive Motor. JMF Axial Piston Motor Peak Pressure: 385 bar Displacement 29~250 cc/r

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Char-Lynn. h y d r a u l i c s. W Series Geroler Motors. Spool Valve Hydraulic Motors

Pressure Gauge Kit and Test Couplings

Char-Lynn Hydraulic Motor. Repair Information Series. April, 1997

Solutions. We Manufacture. H y d r a u l i c s. Eaton Light Duty Hydrostatic. h y d r a u l i c s

Heavy Duty Hydrostatic Transmissions

EATON 750, 780 HYDROSTATIC TRANSAXLE

Standard Power Units Start-Up and Maintenance

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed Circuits

Sepehr Hydraulic Asia

Eaton Contamination Control Products FT1455-L4 Bench mount launcher operating instructions

MDG Mobile Directional Valve Build Kit. MDG for Mobile Equipment Flows to 60 I/min (15.8 US gpm)

620 Mobile open circuit Piston pump service manual ADY074 ADY098

Eaton Contamination Control Products FT1455-L3 Hand held launcher operating instructions

Eaton Contamination Control Products FT1455-L2 Hand Held Launcher Operating Instructions

220 Piston pump Service manual AEC 028

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

Axial Piston Pumps and Motors Service Manual

Series 20 Axial Piston Pumps. Technical Information

Solutions. ydraulics. Manufacture. H y d r a u l i c s. Eaton Hydrostatic Transaxles. h y d r a u l i c s

Constant Speed Control

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

A better solution for your toughest light-duty motor challenges.

Superior performance and reliability. Eaton Xcel Series Low-Speed High-Torque Motors

Ultronics ZTS16 Twin Spool Valve

FT1455-L3 Hand Launcher Operating Instructions

FT1455-L2 Hand Launcher Operating Instructions

Series 20 Axial Piston Pumps. Technical Information

VIS (Valve-In-Star) Hydraulic Motor

Piston Pumps Series P2 / P3 Variable Displacement

Series 1 Model Codes

Heavy-Duty Series 2 Hydrostatic Piston Pumps. Model 5422 Model Model 3322 Model 3922 Model Parts and Service

Section 5: Hydraulic Pump SAUER DANFOSS. SERVICE MANUAL Property of American Airlines. 5-5 Page 1 September 09 HYDRAULIC PUMP

420 Mobile Piston Pump

Series 1 shaft seal installation instructions

Hydraulic Maintenance & Troubleshooting. Content - Norman Kronowitz Presenter Jim Trinkle

PUMP SCPD 56/26 DIN BY-PASS

Troubleshooting the Transmission Hydraulic System

BDU-10/21 Hydrostatic Transmissions Service and Repair Manual

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

Section 3.2. Machine Maintenance - Hydraulic Oil and Tank Information

Eaton Electronic Proportional (EP) Control for Medium Duty Piston Pumps

VIS 40 Series Brake Motors Parts and Repair Manual -004

Instruction manual. Installation requirements. Power Take-Off. Pump mounting: Spline shaft DIN 5462 / ISO 14. Mounting flange ISO 7653-D.

EN Char-Lynn. Spool Valve Hydraulic Motors. Parts Information. W Series Geroler Motors with Parking Brake 004

CMA200 Advanced Subject Independent-Metering title Mobile Valve. 200LPM 440 bar CAN Bus

Solenoid Operated Directional Valve

420 Mobile piston pump Service manual

Heavy Duty Hydrostatic Transmissions

CLS180 Proportional Load Sensing Mobile Valve

How to Identify Fluid Ports and Connectors

Servo-Performance Proportional Directional Valves with Feedback Pressures to 315 bar (4500 psi) KBSDG4V-5 1* Series

Series TMM Axial Piston Motor. Technical Information

Series 2 Variable Displacement Piston Pump

Electronic Proportional (EP) Control for Heavy Duty Series 0/1 Piston Pumps Model 33 Model 39 Model 46. Model 54 Model 64 Model 76

Electronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33

Fixed Displacement Gear Pumps

Char-Lynn T-Series General Purpose Geroler Motor

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

Eaton Fixed Displacement HHD Motor and Variable ACA Pump

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Eaton Directional Control Valves. h y d r a u l i c s. Models and 31930

Eaton Weatherhead ET4001 Crimp Machine Operator's Manual

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm)

Electronic Proportional (EP) Control for Medium Duty Piston Pumps

No July, Eaton. Hydraulic Motor. Repair Information. 30 Series VIS Bearingless Motor 002

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Mobile Directional Valve. Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm)

G.O. 80w90. Product Data. Premium Extreme Pressure Gear Oil. Typical Gear Box Problems: 4 Dry Starts. 4 Upper and Middle Gear Failure

Axial Piston Variable Pumps Series 40 M46 Tandem

Transcription:

Eaton Heavy Duty Hydrostatic Transmissions July, 1995 Ready Mix Concrete Troubleshooting Guide f Eaton Hydrostatic Transmissions used on Concrete Mixers

Contents Introduction... 2 Typical Hydrostatic System... 3 Gauge Requirements, Gauge Pt Size and Locations...4-5 Typical Pressure Readings... 6 Fault-Logic Troubleshooting...7-11 Action Step Comments...12-13 Hydraulic Fluid Recommendations...14-15 Introduction This manual provides troubleshooting infmation f a typical hydrostatic system. It will help you to diagnose min problems that may occur with Eaton Heavy Duty Hydrostatic Transmissions. The following publications are also available f Eaton Heavy Duty Hydrostatic Transmissions: Technical Data f Hydrostatic Closed-Circuit Schematics... No. 3-403 Eaton Heavy Duty Hydrostatic Start-Up Procedure... No. 2-402 Eaton Hydrostatic Variable Pump Manual (Series 0)... No. 7-603 Eaton Hydrostatic Variable Pump Manual (Series 1)... No. 7-606 Eaton Hydrostatic Fixed Pump Manual (Series 0)... No. 7-122 Eaton Hydrostatic Fixed Pump Manual (Series 1)... No. 7-127 2

Typical Hydrostatic System Variable Pump-Fixed Mot 11 12 9 10 3 4 5 6 7 1 8 2 1 Variable Displacement Pump 2 Fixed Variable Displacement Mot 3 Reservoir 4 Shut-off Valve (Optional) 5 Filter 6 Charge Pump Inlet Line 7 Pump and Mot Case Drain Lines 8 High Pressure Lines 9 Heat Exchanger 10 Heat Exchanger By-pass Valve 11 Reservoir Return Line 12 Reservoir fill Cap and Breather 3

Gauge Requirements, Gauge Pt Size and Locations Variable Displacement Pumps Charge Pressure Gauge 0-37 bar [0-600 PSI ] Inlet Vacuum Gauge -1 to + 2 bar [- 30 to + 30 in. Hg (Mercury)] ( Compound Gauge ) 300 200 400 10 0 5 10 15 100 500 PSI 0 600 20 20 Compound 25 30 30 Vac Press Charge Pressure B A 7/16-20 UNF 2B - 4 SAE O-Ring Pt 1-5/16-12 UN 2B -16 SAE O-RIng Pt Optional Power Limiter Valves Customer must supply fitting Fixed Displacement Mot Case Pressure Gauge 0-20 bar [0-300 PSI] System Pressure Gauges ( 2 ) 0-610 bar [0-10,000 PSI] 150 100 200 5000 4000 6000 3000 7000 5000 4000 6000 3000 7000 Customer must supply Fitting 50 250 PSI 0 300 2000 8000 1000 0 PSI 10000 9000 2000 8000 1000 0 PSI 10000 9000 1-1/16-12 UN 2B - 12 SAE O-Ring Pt Charge Pressure Relief Valve 7/16-20 UNF 2B - 4 SAE O-Ring Pts B A Optional Case Pressure Gauge Location Optional Speed Sens Shuttle Valve High Pressure (A Pt) High Pressure (B Pt) 4

Gauge Requirements, Gauge Pt Size and Locations Fixed Displacement Mots (with Integral Shuttle) Case Pressure Gauge 0-20 bar [0-300 PSI] System Pressure Gauges ( 2 ) 0-610 bar [0-10,000 PSI] 150 100 200 5000 4000 6000 3000 7000 5000 4000 6000 3000 7000 Customer must supply Fitting 50 250 PSI 0 300 2000 8000 1000 0 PSI 10000 9000 2000 8000 1000 9/16-18 UNF 2B - 6 SAE O-Ring Pts 0 PSI 10000 9000 1-1/16-12 UN 2B - 12 SAE O-Ring Pt System Pressure Gauge Pt (B) System Pressure Gauge Pt (A) Shuttle Valve B A Optional Case Pressure Gauge Location Optional Speed Sens Charge Pressure Note: To protect your instrumentation, all gauges should be dampened ( snubbed) and mounted with flexible lines. 5

Pressure Readings The pressures given in this manual are gauge pressures delta pressures. A pressure gauge reads zero when connected to atmospheric pressure. Any reading above below this zero point is referred to as gauge pressure (bar [PSI]). Delta pressure is the difference of two gauge pressures in a hydraulic circuit. Example: Charge pressure reading of 16,5 bar [240 PSI] - Case pressure reading of 1,5 bar [20 PSI] Differential pressure of 15,0 bar [220 PSI] Typical hydrostatic circuits usually include a inlet pressure, case pressure, low charge pressure and system high pressure. These pressures will vary per each individual application and operating conditions. Nominal Operating Pressures (At Nmal Operating Temperature) Inlet Vacuum: Case pressure: Should not exceed 254 mm [10 in.] mercury (Hg.) f an extended period of time Should not exceed 2,8 bar [40 PSI] f an extended period of time Charge Pressure:* Neutral 15,2 bar [220 PSI] Fward Reverse 11,0 bar [160 PSI] *Charge Pressure Relief valves are facty preset to their nominal setting with a 7,6 l/min [2 GPM] flow rate. The iginal valve pressure will increase approximately,45 bar per 3,8 l/min [6.5 PSI per 1 GPM] additional flow over the valve. The charge pressures given above are typical. Higher charge pressures may be set at the facty f your particular application. 6

Fault-Logic Troubleshooting This guide is designed as a diagnostic aid f the user to locate possible transmission problems. Match the transmission symptoms with the problem statements and follow the action steps shown in the box diagrams. This will help in crecting min problems, eliminating unnecessary mixer down time. Following the fault-logic diagrams are diagram action comments to further help explain the action steps shown in the diagrams. Where applicable, the action comment number of the statement appears in the action block of the diagram. Action Step Comment Number Decision Symptom: 1? Ok Solution Neutral Difficult Impossible to Find 1 External Pump Control Linkage (if Used) Pump Control Valve 2 Pump 7

Drum Turns in One Direction Only External Pump Control Linkage (if Used) 2 Pump Control Valve 3 System Relief Power Limiter Valves 1 Pump Charge Check Valves 5 Shuttle Valve 4 8

Check Oil Level in Reservoir 6 Below Level Fill to Proper Level Transmission (Pump & Mot) Charge Pump 14 Hydraulic System Operating Hot 9 Check Engine R.P.M. 7 Heat Exchanger Low Clogged Increase Engine R.P.M. Clean System Relief Power Limiter Valves 3 Inlet Filter 10 Charge (At Pump) 12 Clogged 8 Heat Exchanger By-Pass Valve (if Used) Check Charge Pressure 11 Low in Neutral,Fward Reverse Low in Fward Reverse Charge (At Mot) 13 9

13 Check Charge Pressure Low In Neutral Charge 12 (At Pump) Drum Response Sluggish 2 Pump Control Valve Low in Fward Reverse Low in Neutral,Fward Reverse Charge 13 (At Mot) Charge 12 (At Pump) 10 Inlet Filter Clogged Transmission (Pump & Mot) 14 Charge Pump 10

Drum Stalls Will Not Turn In Either Direction Check Oil Level in Reservoir 1 External Pump Control Linkage (if Used) 9 Check Engine R.P.M. 11 Check Charge Pressure 6 Below Level Low Fill to Proper Level Increase Engine R.P.M. Low in Neutral,Fward Reverse Low in Fward Reverse Charge Pump 14 Inlet Filter 10 Charge (At Pump) 12 Charge (At Mot) 13 Clogged Transmission (Pump & Mot) Pump Control Valve 2 System Relief Power Limiter Valves 3 11

Diagram Action Step Comments 1. External Pump Control Linkage f: (Manual Operated Controls) A. Misadjusted disconnected B. Binding, bent broken (Electrical Operated Controls) A. Disconnected electrical signal connection 2. Pump Control Valve f: (Manual Operated Controls) A. Plugged control ifice B. Damaged mounting gasket C. Misadjusted, damaged broken neutral return spring D. Broken control connect pin E. Broken missing control linkage pin(s) F. Galled, stuck bent control spool (Electrical Operated Controls) A. Plugged control ifice B. Damaged mounting gasket C. Galled, stuck bent control spool D. Stuck solenoid valve(s) E. solenoid coil(s) F. Misadjusted speed sens (when used) G. speed sens (when used) H. electronics module NOTE: When the electronic transit mixer control is used, follow the control box fault dect instructions. 3. System Relief Power Limiter Valves f: (System s) A. Improper pressure relief setting (Consult owners/operat manual f system relief valve settings.) B. Damaged missing O-ring and/ back-up ring(s) C. Plugged ifice D. Piston galled stuck E. Valve poppet held off seat (Power Limiter Valves) A. Improper pressure relief setting (Consult owners/operat manual f power limiter valve settings.) B. Broken spring C. Valve held off seat 4. Shuttle Valve f: A. Bent broken return centering spring B. Galled stuck shuttle spool C. Bent broken shuttle spool 5. Charge Check Valves f: A. Damaged missing O-ring and/ back-up ring(s) B. Damaged check ball seat C. Stuck check ball 6. Check Oil Level in Reservoir: A. Consult owner/operats manual f the proper type fluid and level. 7. Heat Exchanger f: A. Obstructed air flow (air cooled) B. Obstructed water flow (water cooled) C. Improper Plumbing (inlet to outlet) D. Obstructed insufficient fluid flow E. Cooling fan Failure (if used) 8. Heat Exchanger By-Pass Valve f: A. Improper pressure setting B. Stuck broken valve 9. Check Engine R.P.M. A. Consult owner/operats manual f minimum engine rpm. 10. Inlet Filter f: A. Plugged clogged filter B. Obstructed inlet outlet C. Collapsed inlet line to charge pump D. Open inlet to charge pump 11.* Check Charge Pressure: A. Consult page 4 in this manual f charge pressure gauge installation location. B. Consult owner/operats manual f charge relief valve settings. 12.* Charge f: (at Pump) A. Improper charge relief pressure setting B. Plugged Orifice C. Piston galled stuck open and/ closed D. Damaged missing O-ring E. Valve poppet held off seat 12

Diagram Action Step Comments 13.* Charge f: (at Mot) A. Improper charge relief pressure setting B. Plugged Orifice C. Piston galled stuck open and/ closed D. Damaged missing O-ring E. Valve poppet held off seat 14. Charge Pump f: (Standard and A-Pad Pumps) A. Broken drive tang B. Damaged missing o-ring(s) C. Broken drive key E. Galled broken gerot set (B-Pad Pumps) A. Stripped broken drive coupling B. Stripped broken drive spline C. Damaged missing o-ring(s) D. Broken drive key F. Galled broken gerot set *System / Charge Pressure Setting Identification The system and charge pressure relief valves are all facty preset. F identification, a pressure code is stamped on the hex plug located on the end of the system and charge pressure valve cartridges. This same code is also used on the power limiter valves. The code number is stamped on the end of the valve cartridge. (Power limiter valves must be removed to view pressure code.) To determine the pressure setting of each valve, add a zero to the right of the stamped coded number. Charge Pressure Valve Examples 016 = 160 PSI Setting [ 11,0 bar ] 022 = 220 PSI Setting [ 15,2 bar ] System and Power Limiter Valve Pressure Examples 400 = 4000 PSI Setting [ 275 bar ] 500 = 5000 PSI Setting [ 345 bar ] 13

Hydraulic Fluid Recommendations Introduction The ability of Eaton hydraulic components to provide desired perfmance and life expectancy depends largely on the fluid used. The purpose of this document is to provide readers with the knowledge required to select the appropriate fluids f use in systems that employ Eaton hydraulic components. One of the most imptant characteristic to consider when choosing a fluid to be used in a hydraulic system is viscosity. Viscosity choice is always a compromise; the fluid must be thin enough to flow easily but thick enough to seal and maintain a lubricating film between bearing and sealing surfaces. Viscosity requirements f each of Eaton s product lines are given on the back of this document. Viscosity and Temperature Fluid temperature affects viscosity. In general, as the fluid warms it gets thinner and its viscosity decreases. The opposite is true when fluid cools. When choosing a fluid, it is imptant to consider the start-up and operating temperatures of the hydraulic system. Generally, the fluid is thick when the hydraulic system is started. With movement, the fluid warms to a point where a cooling system begins to operate. From then on, the fluid is maintained at the temperature f which the hydraulic system was designed. In actual applications this sequence varies; hydraulic systems are used in many environments from very cold to very hot. Cooling systems also vary from very elabate to very simple, so ambient temperature may affect operating temperature. Equipment manufacturers who use Eaton hydraulic components in their products should anticipate temperature in their designs and make the appropriate fluid recommendations to their customers. Cleanliness Cleanliness of the fluid in a hydraulic system is extremely imptant. Eaton recommends that the fluid used in its hydraulic components be maintained at ISO Cleanliness Code 18/13 per SAE J1165. This code allows a maximum of 2500 particles per milliliter greater than 5 µm and a maximum of 80 particles per milliliter greater than 15 µm. When components with different cleanliness requirements are used in the same system, the cleanest standard should be applied. OEM s and distributs who use Eaton hydraulic components in their products should provide f these requirements in their designs. A reputable filter supplier can supply filter infmation. Fluid Maintenance Maintaining crect fluid viscosity and cleanliness level is essential f all hydraulic systems. Since Eaton hydraulic components are used in a wide variety of applications it is impossible f Eaton to publish a fluid maintenance schedule that would cover every situation. Field testing and moniting are the only ways to get accurate measurements of system cleanliness. OEM s and distributs who use Eaton hydraulic components should test and establish fluid maintenance schedules f their products. These maintenance schedules should be designed to meet the viscosity and cleanliness requirements laid out in this document. Fluid Selection Premium grade petroleum based hydraulic fluids will provide the best perfmance in Eaton hydraulic components. These fluids typically contain additives that are beneficial to hydraulic systems. Eaton recommends fluids that contain anti-wear agents, rust inhibits, anti-foaming agents, and oxidation inhibits. Premium grade petroleum based hydraulic fluids carry an ISO VG rating. SAE grade crankcase oils may be used in systems that employ Eaton hydraulic components, but it should be noted that these oils may not contain all of the recommended additives. This means using crankcase oils may increase fluid maintenance requirements. Hydraulic fluids that contain V.I. (viscosity index) improvers, sometimes called multi-viscosity oils, may be used in systems that employ Eaton hydraulic components. These V.I. improved fluids are known to shear-down with use. This means that their actual viscosity drops below the rated value. Fluid maintenance must be increased if V.I. improved fluids are used. Automotive automatic transmission fluids contain V.I. improvers. Synthetic fluids may be used in Eaton hydraulic components. A reputable fluid supplier can provide infmation on synthetic fluids. Review applications that require the use of synthetic fluids with your Eaton representative. 14

Viscosity Requirements ISO Optimum Cleanliness Product Line Minimum Range Maximum Requirements Comments Heavy Duty Piston 60 SUS 80-180 SUS 10,000 SUS 18/13 Pumps and Mots [10 cst] [16-39 cst] [2158 cst] Additional Notes: Fluids too thick to flow in cold weather start-ups will cause pump cavitation and possible damage. Mot cavitation is not a problem during cold start-ups, except f two speed mots. Thick oil can cause high case pressures which in turn can blow mot shaft seals. When choosing a hydraulic fluid, all the components in the system must be considered and the optimum viscosity range adjusted accdingly. F example, when a medium duty piston pump is combined with a Geroler mot the optimum viscosity range becomes 100-150 SUS [20-32 cst] and viscosity should never fall below 70 SUS [13 cst]. If the natural col of the fluid has become black it is possible that an overheating problem exists. If the fluid becomes milky, water contamination may be a problem. Take fluid level reading when the system is cold. Contact your Eaton representative if you have specific questions about the fluid requirements of Eaton hydraulic components. 15

Eaton Fluid Power Group Hydraulics Business USA 14615 Lone Oak Road Eden Prairie, MN 55344 USA Tel: 952-937-9800 Fax: 952-294-7722 www.eaton.com/hydraulics Eaton Fluid Power Group Hydraulics Business Europe Route de la Longeraie 7 1110 Mges Switzerland Tel: +41 (0) 21 811 4600 Fax: +41 (0) 21 811 4601 Eaton Fluid Power Group Hydraulics Business Asia Pacific 11th Flo Hong Kong New Wld Tower 300 Huaihai Zhong Road Shanghai 200021 China Tel: 86-21-6387-9988 Fax: 86-21-6335-3912 2008 Eaton Cpation All Rights Reserved Printed in USA Document No. E-PUPI-TM009-E Supersedes 03-406 November 2008