A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

Similar documents
A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities.

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL

SECTION MOTOR REQUIREMENTS for HVAC

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

SECTION MOTORS & MOTOR CONTROLLERS

SECTION OWNER FURNISHED EQUIPMENT

SECTION GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT

SECTION MOTOR CONTROL

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base

Modifiable TITAN Horizontal Motors Accessories and Modifications

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Horizontal Motors Conversions & Accessories Descriptions & Adders

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES

SUBMERSIBLE PUMPS DRAINER SUMP/EFFLUENT

SUPER-MAX INDUCTION MOTOR

AC Induction Motors. Installation and operating instructions

Use the following standards for system design and performance requirements.

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

Large AC Motors. Synchronous Reluctance Kiln Duty Submersible Accessories & Kits. Large AC Motors. Modifications Large AC M-211

GENERAL Proposal 1) Bid Sheet REPLACE -Section Page 12 & 13 of Section 0300 BID SHEET with the attached revised document.

Severe Duty / IEEE TEFC Motors SD100 IEEE841 / RGZEESDX

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

MAX-E1 HIGH EFFICIENCY. Severe Duty

ABMA , Radial Bearings of Ball, Cylindrical Roller and Spherical Roller Types Metric Design.

NEMA Premium Efficiency T-Frame Motors. Three-Phase, TEFC Enclosures RELIABILITY MATTERS

NEMA & IEC Product Features and Benefits

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 92

Climas y Proyectos Leyco, S.A. de C.V.

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA MG1 (2003) Part 31,

Industrial Control Transformers

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2

SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

ROGERS MACHINERY COMPANY, INC

XLE50 FLOW RATE (LPM) Flow Rate (GPM)

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

ROGERS MACHINERY COMPANY, INC

Severe duty cast iron frame motors

7.0 High HP Low and Medium Voltage

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

DSZ3. EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

Horizontal Circuit Switchers

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

Horizontal Circuit Switchers

Integral Horsepower AC Induction Motors ODP Enclosure TEFC Enclosure

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

INDUCTION MOTOR. There is no physical electrical connection to the secondary winding, its current is induced

General purpose aluminum frame motors. The right choice for efficiency and performance. SIMOTICS NEMA Low Voltage Motors.

REVISIONS App PC. App Sud. App Thom TC 2014/03/25

Design Standard. Purpose: Design Standard:

Dry Type Distribution Transformers

PERFORMANCE DATA 3-PHASE INDUCTION MOTOR

INDEX NEMA PREMIUM EFFICIENCY

AF series contactors (9 2650)

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

SKHS SERIES 2 HP 1-1/2 HP 1 HP 1/2 HP CAPACITY-U.S. G.P.M.

SPD50H/100H. Performance Data SPD100H SPD50H. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

Maximum operating temperature for standard motors = 110 C. Shut down temperature in case of a malfunction = 115 C.

Pump Specifications 250 Series Submersible Sump / Effluent Pump

Starting of Induction Motors

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

General purpose cast iron frame motors. The right choice for optimal durability, efficiency and performance. SIMOTICS NEMA Low Voltage Motors

Overload Relay Heater Tables

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

EPACT ENERGY POLICY ACT OF 1992: THE SCOPE OF ELECTRIC MOTORS SUBJECT TO EFFICIENCY STANDARDS ON OCTOBER

Over 525 Stock Motor Ratings. The Right Pump Motor for your Application. Leadership in Premium Efficiency. 1

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM

Motor Basics AGSM 325 Motors vs Engines

Integral Horsepower AC Induction Motors ODP, WPI, WPII Enclosure TEFC Enclosure Explosion Proof

Pump Installation and Service Manual HRS Hydromatic Retractable System

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR CLASSIFICATION. 2010, The McGraw-Hill Companies, Inc.

GE Energy. X$D Ultra 841. NEMA Premium Extra Severe Duty Motors Frame HP

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

SKV40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 2" Solids: 2" GPM: TDH:

EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

Pump Specifications. ELV Series Submersible Sump Pump with OilTector Control. ELV250 1/3 hp ELV280 1/2 hp ELV290 3/4 hp

Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power.

JDL SYSTEMS Submersible Sump / Sewage Pumps Table of Contents Project: Model: Chk d: Date:

Single and Three Phase General Purpose Motors

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

PERFORMANCE DATA 3-PHASE INDUCTION MOTOR

X$DUltra NEMA Premium 7 Extra Severe Duty Motors Frame 3/4-250 HP

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

SECTION ELECTRIC MOTORS

Stearns Heavy Duty Clutches & Brakes... Rugged, Reliable

Generator Fire Safety: Generator assemblies should be located outside the building.

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

Transcription:

PART 1: GENERAL 1.01 This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is to apply the principles of this section such that the University may achieve a level of quality and consistency in the design and construction of their facilities. Deviations from these guidelines must be justified through LCC analysis and submitted to the University for approval. 1.02 Standards A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents. 1.04 Warranties 1 NEMA MG 1 - Motors and Generators. 2. ANSI/IEEE 112 - Test Procedures for Motors / Generators. 3. UL 1004 - Motors, Electric. 4. UL 674 - Motors, Generators, Electric, for Use in Hazardous Locations: Class I, Groups C and D; Class II, Groups E, F, and G. 5. Provide minimum nominal motor efficiency per the latest version of ASHRAE 90.1. A. Vendor shall provide the standard form of written guarantee and warranty covering defects in materials and workmanship for the equipment. Said guarantee and warranty shall be for a period of one year from the date of final acceptance of the equipment by The University. Date of acceptance shall be defined as the date that The University assumes operation of the unit. PART 2: PRODUCTS 2.01 Motors Less Than 1/2 Hp A. Unless otherwise specified, motors less than 1/2 hp shall be squirrel-cage, induction type, capacitor start with copper stator windings as the Standard low-horsepower motor. B. Motors shall be continuously rated with 1.15-service factor for operation at 115 volts, single-phase, 60 Hz. C. The driven load for constant speed applications shall not exceed the motor's continuous nameplate rating, exclusive of any service factor, under any normal operating condition. Design & Construction Standards, Revised November 2007 5.26.60-1

2.02 Motors Larger Than 1/2 Hp Through 250 Hp A. Motors shall be 3-phase, continuously rated, squirrel-cage, random-wound copper, induction motors designed for 460 volt, 60 Hz operation. Provide motors rated for continuous operation with 1.15-service factor. Motors 7.5 HP and larger shall be 3- phase 480 volt only. B. Provide motors with Class F insulation and a Class B temperature rise based on 40 degrees C ambient. When ambient temperatures exceed 40 degrees C, temperature rise shall be adjusted according to MG 1-12. Locked Rotor Current: Provide motors with locked rotor starting currents not exceeding Code L under 3 hp, Code K for 3 and 5 hp, Code H for 7-1/2 and 10 hp, and Code G for 15 hp and above. C. Provide motors meeting the energy efficiency and power factor requirements of ASHRAE 90.1 Table 6.8 Minimum Equipment Efficiency Tables for minimum nominal efficiency, when tested in accordance with NEMA MG 1-12.53a and IEEE Standard 112, Test Method B. D. Provide motors rated for continuous operation with 1.15-service factor. For constant speed motors, the driven load shall not exceed the motor's brake horsepower nameplate rating, exclusive of any service factor, under any normal operating condition. E. Provide all TEFC motors with anti-friction grease lubricated ball bearings, with a bearing AFBMA B-10 life of 100,000 hours, and sealed from the environment. Provide factory lubrication of all motors prior to shipment. Provide all grease-lubricated bearings with relief fittings. F. Provide all ODP motors with sealed anti-friction grease lubricated ball bearings, with a bearing AFBMA B-10 life of 100,000 hours. Provide factory lubrication of all motors prior to shipment. Provide all grease-lubricated bearings with relief fittings. G. Motors which are located outside or wherever specified shall be provided with space heaters sized to prevent moisture condensation, rated 120 volts, with a separate conduit box for heater leads only. H. For motors 5 horsepower and larger, provide a snap action normally closed Klixon embedded in the stator winding at the 12:00 position with tee leads wired out to the wiring compartment. The temperature of the Klixon shall be set for 25% of the insulation temperature rating. I. Provide motors with conduit boxes that are fully rotatable, diagonally split, including gasket between cover and box, and box and frame, with threaded hubs and a grounding lug located within the box for ground conductor connection. J. Provide nameplates of stainless steel or other approved corrosion resistant material to Design & Construction Standards, Revised November 2007 5.26.60-2

provide a permanent legible marking, containing NEMA data plus guaranteed minimum efficiency. Attach nameplates and connection plates to the motor frame by rivets or screws. K. Variable torque, inverter duty rated motors shall be provided for variable speed applications. Insulated bearings shall be used for motors driven by variable frequency drives. 2.03 Motor Types A. The following Standard motor types shall conform to the following requirements: 1. Horizontal Dripproof: Provide horizontal motors with an enclosure that meets NEMA Standard MG 1 for open, dripproof construction. Provide screen over all air openings. 2. Horizontal Totally Enclosed Fan-Cooled: Provide totally enclosed fan-cooled (TEFC) motors with frame sizes 182 and larger with cast iron frames and end shields. Smaller frame sizes may be constructed of rolled steel with cast metal end shields. Provide motors with condensate drain holes. For frame size 286 and larger, provide automatic breather/drain device in drain hole. 3. Vertical Weather Protected Type I: Provide vertical motors with an enclosure that meets NEMA Standard MG 1 for weather protected Type I (WP-I) enclosure. Provide screens over all air openings. 4. Vertical Totally Enclosed Fan-Cooled: Provide vertical motor with an enclosure identical to the requirements for the horizontal TEFC motors. 5. Explosion proof: Provide all horizontal and vertical motors with TEFC explosion proof enclosures, UL listed for Class 1, Division 1, Group D hazardous atmosphere. Provide motors manufactured by Reliance Electric, or equal. 6. Submersible: Submersible motors UL listed for explosion proof atmospheres in accordance with subsequent sections of this specification. In addition, provide submersible motors with two mechanical seals; the lower one outside the motor and protecting the upper one, which is in an oil filled chamber. Provide moisture detector probes in the oil filled seal chamber to indicate the presence of moisture in the seal chamber. Provide a temperature detector and switch rated 3 amperes, 120 volts minimum, set to operate when the internal motor temperature exceeds a preset limit. Provide any relays or solid-state controls for separate mounting. 7. Horizontal, Totally Enclosed, Fan-Cooled, Severe Duty: Provide horizontal (TEFC), severe duty motors suitable for contaminated environments, including gasketed conduit box, stainless steel drains, double-shielded bearings, and corrosion resistant paint. Provide motors manufactured by Reliance Electric SXT-XT-XE, Century Type SCE E-Plus, or equal. 8. Vertical, Totally Enclosed, Fan-Cooled, Severe Duty: Provide vertical (TEFC), severe duty motors with the requirements identical to horizontal (TEFC), severe Design & Construction Standards, Revised November 2007 5.26.60-3

severe duty motors, above. 2.04 Motors For Use With Variable Frequency Drives A. Motor Application Considerations: 1. NEMA Standard MG1 definite purpose inverter duty rated motors shall used for all variable frequency drive installations. The inverter duty motors shall be able to withstand voltages greater than 1600 volts peak and rise times of 0.1 microsecond. 2. Applications where the motor specification does not meet NEMA MG1 Part 31 (1600V peak and 0.1 microsecond rise time), and the cable length between the inverter and motor exceeds the drive manufacturer recommended maximum cable length; load sideline reactors shall be used. The load sideline reactor shall be design and constructed to operate with variable frequency inverter drives with switching frequencies up to 20 Khz. Line reactor insulation dielectric strength shall be greater than or equal to 4000 volts and shall carry a UL506 & UL508 approval. 3. Insulated or isolated bearings shall be used for the inverter duty rated motors. 4. The inverter duty motor shall be constructed with triple film wire, increased winding slot insulation, increased insulation between phases, and increased first turn insulation. The inverter duty motor shall use slot fillers as required to avoid loose windings. 5. The inverter duty motor insulation class shall be class F insulation and a class B temperature rise based on 40 degrees C. 6. The inverter duty motor nameplate shall indicate that the motor is an inverter duty motor. 2.05 Motors and Motor Starters A. Specific motors are not generally specified within this section. Refer to appropriate mechanical design requirements for specifics on motors. B. Coordinate with mechanical designer to require only NEMA premium efficiency motors with guaranteed efficiency at least equal to NEMA standards. C. Motors 5 HP or smaller shall have sealed, lubricated-for-life bearings. Motors 71/2 HP or larger shall have antifriction ball or roller bearings, oil or grease lubricated. D. Motors 10 HP and larger shall be 480V, 3 phase; Motors 7 1/2 HP to 1 HP can be 208V, 3 phase motors less than 1 HP can be 120V, single phase. Design & Construction Standards, Revised November 2007 5.26.60-4

E. Motor Starters: Motor starters shall contain a NEMA integer sized contactor; one overload relay per phase; 120 Volt coil for external control power; interlock on disconnect switch to de-energize external voltage control. Where external control power is not provided, include a fused control power transformer, 120 Volt secondary mounted in the starter cabinet only. Starter shall provide for the field installation of up to 3 NO and 4 NC interlocks in addition to the hold-in interlock. Fan starters are to have safety switches on the line side of the motor and/or Variable Frequency Drive. The safety switch is to be located inside large air handler units and close to the air handler unit on small units. Where start/stop functions are controlled through control system, provide a relay in the automatic circuit of the control coil such that a 24V signal will actuate the starter. PART 3: EXECUTION 3.01 Pump Motor Requirements: 1. Wiring Requirements: (a) (b) (c) Connect all pump motors rated at 25 amps or below with a flexible power cord no longer than 3 feet. The cord shall be hard service SO cord, rubber insulated with a neoprene jacket, rated at 90 C, 600V, oil resistant. It should be sized for the motor nameplate amperage: Duplex sump pumps and condensate return pumps should be wired so that each pump is on a separate dedicated circuit. A mechanical alternator is to be provided to alternate operation of the pumps. There should be three floats in the sump; the lowest to energize the first pump, the next highest to energize both pumps, and the highest to operate a N.O. set of contacts for alarm purposes. Some pumps may require emergency power. Coordinate with University of Texas representative for special requirements. 2. Electrical engineer to coordinate cord and NEMA plug/receptacle requirements with mechanical engineer and pump manufacturer. 3.02 Motors and Motor Starters A. Variable speed drives shall be installed on the load side of the motor starter with an internal bypass. B. Single-line diagram shall indicate motor and motor starter size information. If motor starter information is shown on mechanical coordinate such that no Design & Construction Standards, Revised November 2007 5.26.60-5

discrepancies will exist. C. Circuit information for motors may be shown either on panel schedules or the floorplan, but not both to eliminate potential for discrepancies. END OF STANDARD Design & Construction Standards, Revised November 2007 5.26.60-6