Energy Management and Control System for Smart Renewable Energy Remote Power Generation

Available online at ScienceDirect. Energy Procedia 36 (2013 )

Analysis and Design of the Super Capacitor Monitoring System of Hybrid Electric Vehicles

Architecture Design For Smart Grid

REMOTE MONITORING, DUST DETECTING AND CONTROLLING OF SOLAR PHOTOVOLTAIC USING IOT

Intelligent Power Management of Electric Vehicle with Li-Ion Battery Sheng Chen 1,a, Chih-Chen Chen 2,b

Available online at ScienceDirect. Procedia Engineering 170 (2017 )

Improved PV Module Performance Under Partial Shading Conditions

A Smart Prepaid Energy Meter System with GSM Technology

Experimental Study on Overflow Pipe Structure of the Rod Pump with Down-hole Oil-water Hydrocyclone

The microinverter The latest in solar technology

International Journal of Advance Engineering and Research Development. Demand Response Program considering availability of solar power

Experimental Study on Inlet Structure of the Rod Pump with Down-hole Oil-water Hydrocyclone

Remote Area Hybrid Solar-Diesel Power Systems in Tropical Australia

Battery to supply nonstop energy to load at the same time contingent upon the accessibility of the vitality sources. In

Passive Vibration Reduction with Silicone Springs and Dynamic Absorber

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

ScienceDirect. Simulation and Testing of a Typical On-Board Charger for ITB Electric Vehicle Prototype Application

Available online at ScienceDirect. Procedia Engineering 137 (2016 ) GITSS2015

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

A simulator for the control network of smart grid architectures

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Hard- and software implementation and verification of an Islanded House prototype

ANFIS CONTROL OF ENERGY CONTROL CENTER FOR DISTRIBUTED WIND AND SOLAR GENERATORS USING MULTI-AGENT SYSTEM

JJS EMBEDDED BASED AUTOMATIC SOLAR RADIATION TRACKER FOR FARMERS PUMP

Reva Electric Vehicle Conversion to a Hydrogen Fuel Cell Powered Vehicle

Available online at ScienceDirect. Procedia Engineering 129 (2015 ) International Conference on Industrial Engineering

DYNAMIC BEHAVIOUR OF SINGLE-PHASE INDUCTION GENERATORS DURING DISCONNECTION AND RECONNECTION TO THE GRID

SMART NANO GRID ASOLOUTION TO PAKISTAN ENERGY CRISIS

Vehicle-Grid Integration

Implementation of telecontrol of solar home system based on Arduino via smartphone

Optimal Sizing, Modeling, and Design of a Supervisory Controller of a Stand-Alone Hybrid Energy System

Intelligent Energy Management System Simulator for PHEVs at a Municipal Parking Deck in a Smart Grid Environment

CONTROL OF ELECTRICITY THEFT USING ARM7 BASED PREPAID METERING SYSTEM AND GSM MODULE

Sensing of Diesel Vehicle Exhaust Gases under Vibration Condition

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Available online at ScienceDirect. Procedia Technology 25 (2016 )

Applications of Frequency Conversion Technology in Aircompressor

Design and Installation of A 20.1 kwp Photovoltaic-Wind Power System

Feed-in management with Solar-Log

Power Grid and Alternating Current Distribution Research of Renewable Energy Generate Electric Power s Village System

Available online at ScienceDirect. Energy Procedia 42 (2013 ) Mediterranean Green Energy Forum MGEF-13

D-MESH EFFICIENT SOLUTION FOR SMART METERING

Research on Bill of Engineering Quantity and Calculation Standard for Power Grid Marketing Project Bin ZHU 1, Yun HE 1 and Zhang-hua CAI 2

Next-generation SCADA and Control Technologies for Large-scale Use of Photovoltaic Generation on Electric Power Grid

Design & Development of Regenerative Braking System at Rear Axle

Design of Remote Monitoring and Evaluation System for UPS Battery Performance

Optimization of PID Parameters of Hydraulic System of Elevating Wheelchair Based on AMESim Hui Cao a*, Hui Guo b

MPPT Control System for PV Generation System with Mismatched Modules

Abstract- In order to increase energy independency and decrease harmful vehicle emissions, plug-in hybrid electric vehicles

Laboratory Tests, Modeling and the Study of a Small Doubly-Fed Induction Generator (DFIG) in Autonomous and Grid-Connected Scenarios

A STUDY ON ENERGY MANAGEMENT SYSTEM FOR STABLE OPERATION OF ISOLATED MICROGRID

Implementation of Bidirectional DC/AC and DC/DC Converters for Automotive Applications

Optimum Matching of Electric Vehicle Powertrain

Hydraulic Characteristic of Cooling Tower Francis Turbine with Different Spiral Casing and Stay Ring

A conceptual solution for integration of EV charging with smart grids

Smart Operation for AC Distribution Infrastructure Involving Hybrid Renewable Energy Sources

Managing EV Load Workplace Charging Project Utility Perspective

Design and Implementation of an Automatic Power Supply from Four Different Source Using Microcontroller

A Novel DC-DC Converter Based Integration of Renewable Energy Sources for Residential Micro Grid Applications

Control System for a Diesel Generator and UPS

Design of Active and Reactive Power Control of Grid Tied Photovoltaics

Analysis and Design of Independent Pitch Control System

Integrated Monitoring System Design of Hybrid Aircompressors

The Research on Optimal Design of Large Metallurgical Crane

Imminent Smart DC Nano-Grid for Green Buildings A Contemplative View

Analysis of Grid Connected Solar Farm in ETAP Software

The Study of Thermoelectric Power Generation in The Cooling of Fin and Vibration Heat Pipe

Procedia - Social and Behavioral Sciences 195 ( 2015 ) World Conference on Technology, Innovation and Entrepreneurship

InovCity Évora Beyond metering, towards a smarter grid

COMPARISON OF SOLAR TRACKING WITH FIXED PANEL POWER GENERATION (WITHOUT LOAD)

Available online at ScienceDirect. Procedia Engineering 129 (2015 ) International Conference on Industrial Engineering

Multi-level Feeder Queue Dispatch based Electric Vehicle Charging Model and its Implementation of Cloud-computing

Electric Vehicles Coordinated vs Uncoordinated Charging Impacts on Distribution Systems Performance

Intelligent Control Algorithm for Distributed Battery Energy Storage Systems

Design and experiment of hydraulic impact loading system for mine cable bolt

SNMP dedicated to ORVALDI Solar Infini

OVER SPEED AVOIDANCE THROUGH INTELLIGENT SPEED BREAKING SYSTEM

Control Methodology for Peak Demand through Multi-Source Environment at Demand Side

5 kw Multilevel DC-DC Converter for Hybrid Electric and Fuel Cell Automotive Applications

Development of Novel Connection Control Method for Small Scale Solar - Wind Hybrid Power Plant

BMS-3923 Battery Monitoring System

GRAND RENEWABLE ENERGY 2018

Development of an Internet of Things based Electricity Load Management System

Power Flow Management and Control of Hybrid Wind / PV/ Fuel Cell and Battery Power System using Intelligent Control

GMLC Interoperability Technical Review Meeting Ecosystems Panel

A starting method of ship electric propulsion permanent magnet synchronous motor

MAX310 BEESMART SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY Apparent Power Control (APC)

A study on aerodynamic drag of a semi-trailer truck

Impact of Reflectors on Solar Energy Systems

Hardware Implementation of Power Generation using Attic Type Internally Braced Air Exhauster for Industrial Application

A novel use of the hybrid energy storage system for primary frequency control in a microgrid

Electric Vehicle-to-Home Concept Including Home Energy Management

RTOS-CAR USING ARM PROCESSOR

Smart Meter Impact: Enabling Smart Metering System for Consumption Optimisation and Demand Management. By Gregers Reimann

Helsinki Pilot. 1. Background. 2. Challenges st challenge

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

Maximum Solar Energy Saving For Sterling Dish with Solar Tracker Control System

Development of Higher-voltage Direct Current Power Feeding System for ICT Equipment

Driver roll speed influence in Ring Rolling process

Transcription:

Available online at www.sciencedirect.com Energy Procedia 12 (2011) 120 126 ICSGCE 2011: 27 30 September 2011, Chengdu, China Smart Home Renewable Energy Management System A. R. Al-Ali *, Ayman El-Hag, Mujib Bahadiri, Mustafa Harbaji, Yousef Ali El Haj American University of Sharjah, Sharjah, UAE Abstract One of the major attribute of the smart grid is to integrate renewable and storage energy resources at the consumption premises. This paper presents the design, implementation and testing of an embedded system that integrates solar and storage energy resources to a smart home. The proposed system provides and manages a smart home energy requirement by installing renewable energy; and scheduling and arranging the power flow during peak and off-peak period. In addition to that, a two-ways communication protocol is developed to enable the home owner and the utility provider to better optimize the energy flow and the consumption efficiency. A prototype for the proposed system was designed, implemented and tested using a controlled load bank to simulate a scaled random real house consumption behavior. Three different scenarios were tested and the results and findings are reported. 2011 Published by Elsevier Ltd. Open access under CC BY-NC-ND license. Selection 2011 Published and/or peer-review by Elsevier under Ltd. responsibility Selection and/or of University peer-review of Electronic under responsibility of ICSGCE 2011 Science and Technology of China (UESTC). Keywords: Automatic meter reading, component, energy magmanet system, smart gird, samrt home, solar energy 1. Introduction A smart home energy management system is a system capable of exchange commands between households and energy providers to optimize the energy consumptions. This type of collaboration between energy shareholders result in reducing the consumer electrical bill and better manage the peak loads by the electrical utilities [1]. Smart Grid is one of emerging R&D concepts that integrates traditional electrical grid with the recent development of information and telecommunications technologies to improve the efficiency of power generations, transmissions, distributions and consumptions systems [2-6]. One of the key features of the smart grid is the integration of renewable and storage energy resources at the consumption side [4-8]. Another key feature is to enable consumers and utility to communicate with each other to share the responsibility of managing the power flow and consumptions [4-8]. This * Corresponding author. Tel.: +00971-6-515-2939; fax: +00971-6-515-2979. E-mail address: aali@aus.edu. 1876-6102 2011 Published by Elsevier Ltd. Selection and/or peer-review under responsibility of University of Electronic Science and Technology of China (UESTC). Open access under CC BY-NC-ND license. doi:10.1016/j.egypro.2011.10.017

A. R. Al-Ali et al. / Energy Procedia 12 (2011) 120 126 121 paper presents the design of home energy management system that integrates the power resources from the traditional grid and renewable energy sources namely; solar energy and storage energy. A single chip microcontroller is used to multiplex the three power sources to supply the house with its required power based on a communication between the utility and the house owner. The communication protocol, energy flow, demand-response and billing system hardware and software are developed using a home gate and utility server. The home gateway (H-Gateway) is a single chip embedded system integrated with GSM modem and it is installed at the consumer premises. The utility server (U-Server) is a high-end PC and it is installed at the utility headquarter. Consumer and Utility can manage the energy follow and consumption by exchange message between the H-Gateway and U-Server via the GSM modem. Fig. 1 shows the proposed system conceptual model [8]. 2. System Requirements Fig. 1. Proposed system conceptual model. The functional and non-functional requirements of the system are described. To design an optimize hardware and software architectures, the following requirements must be satisfied: 2.1. Functional Requirements: The system s functional requirements are as follows: A two-way communication channel must be estab- lished between the H-Gateway and the U-Server using the GSM modem. Using the established channel, the H-Gateway must be able to get the forecasted peak intervals for the next day from the U-Server. The microcontroller needs to store the readings of the power consumption, measured by the instrument transformers. The microcontroller must take appropriate decisions, based on the peak intervals, to supply, use and control the alternative energy sources. The stored reading of the power consumptions must be sent from the H-Gateway and stored at the U- Server database. The software at the U-Server side must be running 24/7 to parse the readings received by the GSM modem and store them in the database accordingly. A Website must be hosted at the U-Server side to provide an interface for the home users to view their power consumption behavior. Extra layer of service can be added to control the loads at the house using SMS messages. 2.2. Non-Functional Requirements: The nonfunctional requirements of the system are concentrated more on the reliability and the maintainability of the system. Moreover, the look and feel of the provided services, such as the website, has to be user-friendly and accessible by all users. Finally, loading the web pages from the Web Server

122 A. R. Al-Ali et al. / Energy Procedia 12 (2011) 120 126 needs to be fast; hence hosting the Website in a near location. 3. Proposed System Hardware Architecture Based on the systems requirements, the proposed system hardware should have two basic building blocks namely; the H-Gateway and the U-Server. Fig. 2 shows the system hardware architecture. Fig. 2. Proposed system hardware architecture. The H-Gateway block consists of a solar cell, charge converter, battery, DC/AC inverter, energy meter and GSM modem. Details of the actual system hardware are shown in Fig. 3. Fig. 3. Experimental setup The house gets its power from two sources namely; the power grid and the solar cell. The solar cell energy is stored in a battery and then inverted to AC power. The battery can be charged from the solar cell whenever the sun is shining and from the power grid during the off-peak hours if needed. Scenarios for the charging and switching between the alternative power and grid power will be discussed in a later section. The GSM modem is used to provide the communication between the home owner and U-Server. It utilizes the public mobile networks that are managed by the mobile telephone service provider. The U-Server block is located at the utility headquarter. It is a high-end PC with internet access. It hosts the developed energy management system software. Utility personal and home owner are profiled in a way that allows accessing the server and the H-Gateway via the World Wide Web and mobile public networks. Each user has logon user name, password and level of privilege. The server software activities will be described in later section. Fig. 2 shows the system hardware layout.

A. R. Al-Ali et al. / Energy Procedia 12 (2011) 120 126 123 4. Proposed System Software Model The proposed system software is divided into three main functions: Energy-Flow-Control, Communication, and Service modules. The following is a brief description of each: 4.1. Energy-Flow-Control Module This module consists of three functions. It is installed in the H-Gateway controller at home: Random_Behaviour() function: it assigns some random behaviors to the loads; to simulate the loads at the house. Get_Power() function: it reads the current to calculate the power and hence the energy consumption. Switch_Source() function: it connects the load to the grid or to the alternative sources based on the peak hours. 4.2. Communication Module The primary function of this module is to provide the communication between the H-Gateway and U- Server to enable the homeowner and utility. It is used to exchange messages and commend to better optimize the home energy consumption. Below is a short description to each function. Connect_GSM() function: establish a two-way communication between the H-Gateways and the U- Server using the GSM modem. Send_Peak_Hours() function: send the peak hours from the U-Server database to the GSM modem at the H-Gateway.GSM modem. Receive_Peak_Hours() function: receive the peak hours from the U-Server and store them in the microcontroller for controlling purposes. Send_Consumptions(int[] consumption) function: sends the power consumption as an integer array of 24 element, each representing 1 hour of the 24 hours. 4.3. U-Service Module This module is developed and stored in the U-Sever. The following is brief description of this module: Store_Readings(int[] consumption) unction: store the readings in the appropriate record in the database at the U-Server. Display_Consumption() function: display the power consumption for the user on the Website. Create_User() function: creates a user and store his/her information in the database. SMS_Control(): control the loads in the house via SMSs. 5. Energy Flow Scenarios The communication between the utility and consumers decides the system action of sequences. As it is showing to figure 4, the following sequence of actions take place to better manage and optimize the power consumption: First establishes the communication between the H-Gateway and U-Server using the GSM modem. Then, the microcontroller will ask for the forecasted peak hours for the coming day, in order to control the power sources appropriately. Also, the U-Server will be updating the database for the peak

124 A. R. Al-Ali et al. / Energy Procedia 12 (2011) 120 126 hours every day, and it will send those values to all H-Gateways for all customers. After that, the microcontroller will make decisions, based on the retrieved peak hours, to supply power to the load from the grid, alternative sources or both. It will also determine when to charge the batteries and when to use its power. Readings of the power consumption will also be taken and stored by the microcontroller. At the end of 24 hours, those values will be sent to the U-Server and the information will be processed and stored in the correct record in the database. For the services that will be provided for the customers, the customers will be able to retrieve their bills and consumption behavior from the Website. Different types of charts for consumers consumption will be displayed in order to give the homeowner more information on how to manage his/her power consumption. The homeowners will also be able to control a specific load in their houses via SMS message. The message will be received by the H-Gateway and will be processed to turn ON/OFF any desired load. Fig. 4 shows the system sequence diagram. 6. Implementation and Testing Fig. 4. The system sequence diagram. In this study, the price model of Energy Australia demand intervals has been adapted [9]. The pricing intervals appear with the corresponding price model of cent/kwh is shown in Table 1. The system was run for three different random consumption behaviors with a fixed pricing interval. Figs. 5-7 show a time scaled simulation for the house consumption before and after applying the system to the load bank. The blue bars show the house demand curve before using the system, while the yellow bars show the house demand curve after using the system. The pricing of each figure is based on Table 1. As indicated previously, the price model was adopted from Energy Australia peak intervals. The pricings are kept in Australian Dollar, AUD. The following Cumulative Distribution Function (CDF) figures (Figures 8-10) correspond to the previous simulated load curves respectively. It is evident from Figs. 8-10 that a reduction in the consumer bill of 33.5%, 35.7%,

and 32.23% respectively has been achieved. A. R. Al-Ali et al. / Energy Procedia 12 (2011) 120 126 125 Table 1. Pricing Intervals Time Rate in cents/kwh Peak (2pm - 8pm) 40.04 Shoulder (7am to 2pm and 8pm to 10pm) 14.85 Off-peak (all other times) 8.36 Fig. 5. First simulation Fig. 6. Second Simulation Fig. 7. Third Simulation

126 A. R. Al-Ali et al. / Energy Procedia 12 (2011) 120 126 Fig. 8. CDF pricing chart for first simulation Fig. 9. CDF pricing chart for first simulation Fig. 10. CDF pricing chart for first simulation 7. Conclusion A renewable energy resource was integrated with the public power grid to better manage smart home power consumption. Switching between the power from the grid and the renewable energy resource controller was designed, implemented and tested. It was proven that communication between the utility server and home gateway result in managing the peak. Integrating the renewable energy source saved about 33% of the home energy bill. References [1] Molderink, A. Bakker, V. Bosman, M.G.C. Hurink, J.L. Smit, G.J.M, Management and Control of Domestic Smart Grid Technology, IEEE Transactions on Smart Grid, Vol.1, I 2. 2010. Page(s): 109 119. [2] Tongdan Jin; Mechehoul, M.; Ordering Electricity via Internet and its Potentials for Smart Grid Systems, IEEE Transactions on Smart Grid, Vol. 1, I. 3, 2010, Page(s): 302 310. [3] Hamilton, B.; Summy, M.; Benefits of the Smart Grid [In My View], IEEE Power and Energy Magazine, Vol. 9, I: 1, 2011, Page(s): 104-102 [4] Hamidi, V.; Smith, K.S.; Wilson, R.C.; Smart Grid technology review within the Transmission and Distribution sector, IEEE PES Innovative Smart Grid Technologies Conference Europe, 2010, Page(s): 1 8. [5] Radhika, N., Sivalingam, K., Anand, V., Network architecture for smart grids, International Conference on Computer, Communication and Electrical Technology (ICCCET, 2011, Page(s): 24-26 [6] Jinsoo Han; Haeryong Lee; Kwang-Roh Park; Remote-controllable and energy-saving room architecture based on ZigBee communication, IEEE Transactions on Consumer Electronics, Vol. 55, I. 1,2009, Pp: 264-268 [7] Liu, W.-H.E.; Liu, K.; Pearson, D., Consumer-centric smart grid, IEEE PES Innovative Smart Grid Technologies (ISGT), 2011, Page(s): 1 6. [8] Smart Grid Conceptual Framework [online], Accessed June 2011, http://smartgrid.ieee.org/smart-grid-framework-diagram. [9] http://www.energyaustralia.com.au/state/nsw/business/small-and-medium-business/business-products-andservices/electricity/powersmart-time-based-pricing.aspx