1 Available online at ScienceDirect Procedia Technology 2 (216 ) Global Colloquium in Recent Advancement and Effectual Researches in Engineering, Science and Technology (RAEREST 216) Seasonal Loading Impact on Performance of Solar DG for Loss Reduction Based On Capacity Factor Ritu Sharma a, Atma Ram Gupta b* a,b Department of Electrical Engineering,National Institute of Technology Kurukshetra, Kurukshetra , India Abstract This paper proposed a methodology to study the seasonal impact on the performance of solar based Distributed Generator (DG) for loss reduction as a main objective. The random behavior of solar irradiance is modeled using beta probability density functions. IEEE RTS (Reliability Test System) data is used for load modeling. Different modules of solar have been studied and appropriate selection is made using capacity factor approach and VSI method is used for finding the optimum location for placement of SPV (Solar Photo Voltaic). An iterative forward backward/bibc load flow method is used for analysis. The proposed technique has been applied to IEEE 33, IEEE 69 and IEEE 12 bus system and significant reduction of active power losses has been achieved for different seasons of the year The The Authors. Authors. Published Published by Elsevier by Elsevier Ltd. Ltd. This is an open access article under the CC BY-NC-ND license ( Peer-review Peer-review under under responsibility responsibility of the of the organizing organizing committee committee of RAEREST of RAEREST Keywords: Solar photo voltaic; Wind power; Realiability test system; Voltage stability index 1. Introduction With rapidly increasing demand of electrical energy electric utilities are utilizing special technologies to meet the load demand without violating the system constraints; these new technologies include usage of decentralized plant for generation of electricity. Decentralized plants which include non conventional sources like wind and solar energy are generally adopted by utilities due to large abundance of these sources. Intermittent nature of wind and solar is a great challenge for the reliability of system. In literature different papers have been proposed to study this random behavior of the renewable energy sources. Beta modeling is employed to model the solar irradiance in [1]. * Corresponding author. Tel.: address: argupta@nitkkr.ac.in The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license ( Peer-review under responsibility of the organizing committee of RAEREST 216 doi:1.116/j.protcy
2 72 Ritu Sharma and Atma Ram Gupta / Procedia Technology 2 ( 216 ) Weibull distribution function is used in [2]. Optimal placement of DG units affects the system characteristics as explained in [3] therefore; this aspect should be included in the system. VSI and PSI method is used to place the DG optimally in the system as described in [4, ]. Various optimization methods for loss reduction are presented by different authors like genetic algorithm in [6] and PSO is used in [7]. Effect of penetration levels of DG on annual energy losses is studied in [8]. Forward-backward load flow method is explained to study the system performance in [9]. BIBC based load flow technique is explained in [1]. In this paper beta probability distribution function (PDF) is used to model the hourly solar irradiance for different solar modules. To calculate parameters of beta PDF historical data of Jaipur site is used [11]. Optimal module is selected out of several modules based on highest capacity factor [12]. VSI method is used to place the DG optimally in the system and losses are calculated for different seasons of the year. 2. Modeling of solar DG and load In this section models of SPV and load data are presented. Beta modeling is used for solar module and IEEE RTS data is used for load modeling Hourly historical data processing. A 1 year (1986-2) hourly historical data of the Jaipur site is used to determine the hourly solar irradiance. The data has given as per L.A.T (Local Apparent Time) for sunny hours i.e. from 6 am to 7 pm of that site. For performing this task one year is divided into four seasons, where each season consist of three months and further each season is represented by any day within that season. Now this typical day is divided into 24 segments representing each hour from (12am to 12pm) of the day, therefore one segment will consist of 9 irradiance data points (3month*3 days per month) approximately. From this data mean and standard deviations are obtained for each hour which will be utilized in beta modeling of SPV system Solar irradiance modeling It is a widely used function to model the randomness of solar irradiance; the equation which describes the solar irradiance modeling using beta PDF is given by [13] 1 1 s *(1 s) fb() s ( ) (1) ( )* ( ) * (2) 1 1 (1 ) * * Load Modeling The load data used for this system is IEEE-RTS data which supply hourly peak load in percent of daily peak load for each season for weekdays and weekends [14]. 3. Calculation of Output Power from a Solar module This model is one of best method and widely used to model the output power of a PV module. The output power of a PV module is given as follows [13] Ppv= N*FF*Vy*Iy (4) () (6) (3)
3 Ritu Sharma and Atma Ram Gupta / Procedia Technology 2 ( 216 ) I y S[I sc + ] (7) (8) Nomenclature Ppv output power of PV module in kw V oc open circuit voltage. V mpp voltage at maximum power point. N number of module I sc short circuit current. I mpp current at maximum power point FF fill Factor T cy cells temperature in degree celsius during state y. K i current temperature coefficient A/ C Vy voltage of cell during state y nominal operating temperature of cell K v voltage temperature coefficient V/ C. Iy Current of cell during state y s solar irradiance in w/m 2 T A cells temp. in degree Celsius during state y 4. Selection for optimum power module and optimum location 4.1. Capacity Factor The complete analysis is carried out for different modules. The selections for optimum module from different modules are based on capacity factor. The module having highest capacity factor is selected. Capacity factor [12] is given as: CF = (9) where P avg is the annual average power output of DG units and P rated is the rated power output 4.2. Optimum Location Once the module is selected its corresponding output power (for each season) is used to carry out the load flow but optimum location is also required to place the DG in IEEE 33 bus system. Voltage Stability Index method is used for this purpose as in [4]. VSI= (1). Results and discussion The results are obtained for IEEE 33, IEEE 69 and IEEE 12 bus radial distribution system (RDS) for hourly peak load in percent of daily peak (IEEE RTS) for each season using MATLAB software version 7.8, 29 [1]. The base MVA and base KV of the system are 1 MVA and KV respectively. For the system under study three different modules as shown in Table 1 are used to calculate the solar output power. Capacity factor is calculated for all these modules. Module A is having highest capacity factor and can be observed from Fig. 1 so output power of module A is taken for further analysis. To place SPV DG output power optimally in the system VSI method is used. VSI is maximum for bus 6 as observed from Fig. 2. So, 6 th bus is selected as optimal location to place SPV DG. The output power of module A for different seasons is as shown in Fig.3. to Fig.6. The active power losses are obtained without and for IEEE 33 bus with forward backward load flow method and for IEEE 69 and IEEE 12 bus with BIBC load flow method for winter, summer, spring and fall seasons for all 24 hours are as shown in figures from Fig. 7 to Fig. 3.
4 74 Ritu Sharma and Atma Ram Gupta / Procedia Technology 2 ( 216 ) capacity factor Capacity factor for different modules modules VSI branch number Fig.1.Capacity factor for all three modules Fig.2. VSI profile for IEEE33 bus system Pout(kw) Winter Season(Dec,Jan,Feb) Pout(kw) Summer Season(Jun,Jul,Aug) Fig.3 Output power for winter season Fig.4 Output power for summer season Pout(kw) Spring Season(Mar,Apr,May) Pout(kw) Fall Season(Sep,Oct.Nov) Fig. Output power for spring season Fig.6 Output power for fall season Table1. Characteristics of Different PV Modules Module characteristics Module type A B C Watt Peak (W) Open circuit voltage (V) Short circuit current (A) Voltage at maximum power (V) Current at maximum power (A) Voltage temperature coefficient (mv/ C) Current temperature coefficient (ma/ C) Nominal cell operating temperature ( C)
5 Ritu Sharma and Atma Ram Gupta / Procedia Technology 2 ( 216 ) losses losses losses losses Fig.7 Losses for IEEE33 bus for winter weekdays Fig.8 Losses for IEEE33 bus for winter weekends 4 losses losses 4 losses losses Fig.9 Losses for IEEE33 bus for summer weekdays Fig.1 Losses for IEEE33 bus for summer weekends 4 losses losses 4 losses losses Fig.11 Losses for IEEE33 bus for spring weekdays Fig.12 Losses for IEEE33 bus for spring weekends 4 losses losses 4 losses losses Fig.13 Losses for IEEE33 bus for fall weekdays Fig.14 Losses for IEEE33 bus for fall weekends
6 76 Ritu Sharma and Atma Ram Gupta / Procedia Technology 2 ( 216 ) Fig.1 Losses for IEEE69 bus for winter weekdays Fig.16 Losses for IEEE69 bus for winter weekends Fig.17 Losses for IEEE69 bus for summer weekdays Fig.18 Losses for IEEE69 bus for summer weekends Fig.19 Losses for IEEE69 bus for spring weekdays Fig.2 Losses for IEEE69 bus for spring weekends Fig.21 Losses for IEEE69 bus for fall weekdays Fig.22 Losses for IEEE69 bus for fall weekends
7 Ritu Sharma and Atma Ram Gupta / Procedia Technology 2 ( 216 ) Fig.23 Losses for IEEE12 bus for winter weekdays Fig.24 Losses for IEEE12 bus for winter weekends Fig.2 Losses for IEEE12 bus for summer weekdays Fig.26 Losses for IEEE12 bus for summer weekends Fig.27 Losses for IEEE 12 bus for spring weekdays Fig.28 Losses for IEEE 12 bus for spring weekends Fig.29 Losses for IEEE 12 bus for fall weekdays Fig.3 Losses for IEEE 12 bus for fall weekends
8 78 Ritu Sharma and Atma Ram Gupta / Procedia Technology 2 ( 216 ) From the obtained results a significant loss reduction has been observed for different seasons during the sunny hours i.e. from 6 am to 7 pm when SPV DG is providing the output power to the system. 6. Conclusion The main contributions from the studies that have been carried out in this paper are: SPV output power is calculated for different seasons of the year. Capacity factor is utilized to select the optimum SPV module. The optimum location is obtained using VSI. A significant reduction in losses has been obtained for different seasons after placement of SPV module. References [1] Borowy B. S., and Salameh Z. M. Optimum photovoltaic array size for a hybrid wind/pv system. IEEE Transactions on Energy Conversion;1994: 9(3), p [2] Liu Z., Wen F., Ledwich. G. Optimal Sitting and Sizing of Distributed Generators in Distribution Systems Considering Uncertainties. IEEE Transactions on Power Delivery ; 211: 26(4), p [3] Thakur D., Jiang J. Optimal Location and size of DG for enhancing loading margin and reducing system loss. in Power and Energy Society General Meeting (PES), IEEE, 213, p.1-. doi: 1.119/PESMG [4] Murty V.V.S.N., Kumar A. Optimal placement of DG in radial distribution systems based on new voltage stability index under load growth, International Journal of Electric Energy and Power System ; 214: 69, p [] Aman M.M., Jasmon G.B., Mokhlis H. and Bakar A.H.A. Optimal placement and sizing of a DG based on new power stability index and line losses. International Journal of Electric Energy and Power System; 212: 43, p [6] Borges C. L, Falcao D. M. Optimal distributed generation allocation for reliability, losses, and voltage improvement. International Journal of Electric Energy and Power System; 26: 28, p [7] Kayal P. and Chanda C.K. Placement of solar based DGs in distribution system for Power loss minimization and voltage stability improvement. International Journal of Electric Energy and Power System; 213, 3, p [8] Quezada, V. M., Abbad, J. R., & Román, T. G. S. Assessment of Energy Distribution Losses for Increasing Penetration of Distributed Generation. IEEE trans. on PowerSystems; 26: 21( 2), p [9] Ghosh S. and Das D. Method for load-flow solution of radial distribution Networks. IEE Proc. Gener. Transm. Distrib; 1999: 146(6), p [1] Teng J. H. A Direct Approach for Distribution System Load Flow Solutions. IEEE Transactions on Power delivery;23:18(3), p [11] A report on "Solar Radiant Energy over India ", Ministry of New and Renewable Energy, Govt. of India; 29. [12] Atwa Y.M., Saadany E.F.El, Salama M.M.A. and Seethapathy R. Distribution System Loss Minimisation Using Optimal DG Mix. in Power & Energy Society General Meeting, 29. PES '9. IEEE, p.1-6. doi: 1.119/PES [13] Hung D. Q., Mithulananthan N., K. Y. Lee Determining PV Penetration for Distribution Systems With Time-Varying Load Models. IEEE Transactions on Power Systems; 214,29(6), p [14] IEEE Commmitte Report. IEEE Reliability Test System. IEEE Transactions on Power Apparatus and Systems; 1979: PAS-98, 6, p [1] The MATLAB by Mathworks Corporation, MATLAB version 7.8, 29.
Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015
Available online at www.sciencedirect.com ScienceDirect Procedia Technology 21 (2015 ) 507 513 SMART GRID Technologies, August 6-8, 2015 Loss Reduction and Voltage Profile Improvement in a Rural Distribution
More informationAvailable online at ScienceDirect. Energy Procedia 36 (2013 )
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 36 (2013 ) 852 861 - Advancements in Renewable Energy and Clean Environment Introducing a PV Design Program Compatible with Iraq
More informationImproved PV Module Performance Under Partial Shading Conditions
Available online at www.sciencedirect.com Energy Procedia 33 (2013 ) 248 255 PV Asia Pacific Conference 2012 Improved PV Module Performance Under Partial Shading Conditions Fei Lu a,*, Siyu Guo a, Timothy
More informationAvailable online at ScienceDirect. Procedia Engineering 129 (2015 ) International Conference on Industrial Engineering
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 129 (2015 ) 201 206 International Conference on Industrial Engineering Simulation of lithium battery operation under severe
More informationAvailable online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015
Available online at www.sciencedirect.com ScienceDirect Procedia Technology 21 (2015 ) 619 624 SMART GRID Technologies, August 6-8, 2015 Battery Charging Using Doubly Fed Induction Generator Connected
More informationAvailable online at ScienceDirect. Procedia Engineering 170 (2017 )
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 170 (2017 ) 488 495 Engineering Physics International Conference, EPIC 2016 A Study on Integration of 1kW PEM Fuel Cell into
More informationNew York Science Journal 2017;10(3)
Improvement of Distribution Network Performance Using Distributed Generation (DG) S. Nagy Faculty of Engineering, Al-Azhar University Sayed.nagy@gmail.com Abstract: Recent changes in the energy industry
More informationAnalysis of Grid Connected Solar Farm in ETAP Software
ABSTRACT 2017 IJSRSET Volume 3 Issue 3 Print ISSN: 2395-1990 Online ISSN : 2394-4099 Themed Section: Engineering and Technology Analysis of Grid Connected Solar Farm in ETAP Software Komal B. Patil, Prof.
More informationPower Losses Estimation in Distribution Network (IEEE-69bus) with Distributed Generation Using Second Order Power Flow Sensitivity Method
Power Losses Estimation in Distribution Network (IEEE-69bus) with Distributed Generation Using Second Order Power Flow Method Meghana.T.V 1, Swetha.G 2, R.Prakash 3 1Student, Electrical and Electronics,
More informationThe Effect Of Distributed Generation On Voltage Profile and Electrical Power Losses Muhammad Waqas 1, Zmarrak Wali Khan 2
International Journal of Engineering Works Kambohwell Publisher Enterprises Vol., Issue 1, PP. 99-103, Dec. 015 www.kwpublisher.com The Effect Of Distributed Generation On Voltage Profile and Electrical
More informationScienceDirect. Energy Management of PV - Battery based Microgrid System
Available online at www.sciencedirect.com ScienceDirect Procedia Technology 21 (2015 ) 103 111 SMART GRID Technologies, August 6-8, 2015 Energy Management of PV - Battery based Microgrid System Sonal Gaurav
More informationDynamic Modelling of Hybrid System for Efficient Power Transfer under Different Condition
RESEARCH ARTICLE OPEN ACCESS Dynamic Modelling of Hybrid System for Efficient Power Transfer under Different Condition Kiran Kumar Nagda, Prof. R. R. Joshi (Electrical Engineering department, Collage of
More informationRemote Area Hybrid Solar-Diesel Power Systems in Tropical Australia
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 57 (2014 ) 1485 1491 2013 ISES Solar World Congress Remote Area Hybrid Solar-Diesel Power Systems in Tropical Australia Anil Chaudhary
More informationPower Flow Management and Control of Hybrid Wind / PV/ Fuel Cell and Battery Power System using Intelligent Control
I J C T A, 9(2) 2016, pp. 987-995 International Science Press Power Flow Management and Control of Hybrid Wind / PV/ Fuel Cell and Battery Power System using Intelligent Control B. Yugesh Kumar 1, S.Vasanth
More informationEnergy Management and Control System for Smart Renewable Energy Remote Power Generation
Available online at www.sciencedirect.com Energy Procedia 9 (2011 ) 198 206 9 th Eco-Energy and Materials Science and Engineering Symposium Energy Management and Control System for Smart Renewable Energy
More informationINTELLIGENT DC MICROGRID WITH SMART GRID COMMUNICATIONS: CONTROL STRATEGY CONSIDERATION AND DESIGN
INTELLIGENT DC MICROGRID WITH SMART GRID COMMUNICATIONS: CONTROL STRATEGY CONSIDERATION AND DESIGN Presented by: Amit Kumar Tamang, PhD Student Smart Grid Research Group-BBCR aktamang@uwaterloo.ca 1 Supervisor
More informationAnalysis and Design of the Super Capacitor Monitoring System of Hybrid Electric Vehicles
Available online at www.sciencedirect.com Procedia Engineering 15 (2011) 90 94 Advanced in Control Engineering and Information Science Analysis and Design of the Super Capacitor Monitoring System of Hybrid
More informationScienceDirect. Simulation and Testing of a Typical On-Board Charger for ITB Electric Vehicle Prototype Application
Available online at www.sciencedirect.com ScienceDirect Procedia Technology 11 ( 2013 ) 974 979 The 4th International Conference on Electrical Engineering and Informatics (ICEEI 2013) Simulation and Testing
More informationA Novel Distribution System Power Flow Algorithm using Forward Backward Matrix Method
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 10, Issue 6 Ver. II (Nov Dec. 2015), PP 46-51 www.iosrjournals.org A Novel Distribution System
More informationA STUDY ON ENERGY MANAGEMENT SYSTEM FOR STABLE OPERATION OF ISOLATED MICROGRID
A STUDY ON ENERGY MANAGEMENT SYSTEM FOR STABLE OPERATION OF ISOLATED MICROGRID Kwang Woo JOUNG Hee-Jin LEE Seung-Mook BAEK Dongmin KIM KIT South Korea Kongju National University - South Korea DongHee CHOI
More informationAvailable online at ScienceDirect. Physics Procedia 67 (2015 )
Available online at www.sciencedirect.com ScienceDirect Physics Procedia 67 (2015 ) 518 523 25th International Cryogenic Engineering Conference and the International Cryogenic Materials Conference in 2014,
More informationAvailable online at ScienceDirect. Procedia Engineering 129 (2015 ) International Conference on Industrial Engineering
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 129 (2015 ) 563 570 International Conference on Industrial Engineering Improved design of machine for cold cutting of oil pipes
More informationExperimental Study on Overflow Pipe Structure of the Rod Pump with Down-hole Oil-water Hydrocyclone
Available online at www.sciencedirect.com Procedia Engineering 18 (2011) 387 391 The Second SREE Conference on Oil and Gas Engineering Experimental Study on Overflow Pipe Structure of the Rod Pump with
More informationModelling of PV Array with MPP Tracking & Boost DC-DC Converter
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 10, Issue 1 Ver. IV (Jan Feb. 2015), PP 07-13 www.iosrjournals.org Modelling of PV Array with
More informationA Review on Grid Connected 100 kw Roof Top Solar Plant
International Journal of Recent Research and Review, Vol. X, Issue 3, September 2017 ISSN 2277 8322 A Review on Grid Connected 100 kw Roof Top Solar Plant Himanshu Bhardwaj, Tanuj Manglani, Neeraj Kumawat
More informationDesign and Simulation of Grid Connected PV System
Design and Simulation of Grid Connected PV System Vipul C.Rajyaguru Asst. Prof. I.C. Department, Govt. Engg. College Rajkot, Gujarat, India Abstract: In this paper, a MATLAB based simulation of Grid connected
More informationHybrid Energy Powered Water Pumping System
IOSR Journal of Engineering (IOSRJEN) ISSN (e): 2250-3021, ISSN (p): 2278-8719 Vol. 08, Issue 2 (February. 2018), V1 PP 50-57 www.iosrjen.org Hybrid Energy Powered Water Pumping System Naveen Chandra T
More informationAvailable online at ScienceDirect. Procedia Engineering 129 (2015 ) International Conference on Industrial Engineering
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 129 (2015 ) 166 170 International Conference on Industrial Engineering Refinement of hybrid motor-transmission set using micro
More informationDistribution System DER Hosting Capacity IEEE34 PV
Distribution System DER Hosting Capacity IEEE34 PV usa.siemens.com/digitalgrid Analysis Setup Hourly Load Flow Analysis Load Profile: Two Days Peak and Light For each class: Residential, Commercial, Industrial
More informationApplication of HOMER Software in Wind and Solar Resources Integration
IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 10 April 2016 ISSN (online): 2349-784X Application of HOMER Software in Wind and Solar Resources Integration T. Tharankumar
More informationTRANSNATIONAL ACCESS USER PROJECT FACT SHEET
TRANSNATIONAL ACCESS USER PROJECT FACT SHEET USER PROJECT Acronym REPRMs Title ERIGrid Reference 01.006-2016 TA Call No. 01 Reliability Enhancement in PV Rich Microgrids with Plug-in-Hybrid Electric Vehicles
More informationOptimal Placement of Distributed Generation for Voltage Stability Improvement and Loss Reduction in Distribution Network
ISSN (Online) : 2319-8753 ISSN (Print) : 2347-6710 International Journal of Innovative esearch in Science, Engineering and Technology Volume 3, Special Issue 3, March 2014 2014 International Conference
More informationAvailable online at ScienceDirect. Energy Procedia 100 (2016 )
Available oine at www.sciencedirect.com ScienceDirect Energy Procedia 100 (2016 ) 388 395 3rd International Conference on Power and Energy Systems Engineering, CPESE 2016, 8-12 September 2016, Kitakyushu,
More informationMaximization of Net Profit by optimal placement and Sizing of DG in Distribution System
Maximization of Net Profit by optimal placement and Sizing of DG in Distribution System K. Mareesan 1, Dr. A. Shunmugalatha 2 1Lecturer(Sr.Grade)/EEE, VSVN Polytechnic College, Virudhunagar, Tamilnadu,
More informationImpact of Distributed Generation on Reliability of Distribution System
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 8, Issue 1 (Nov. - Dec. 2013), PP 42-50 Impact of Distributed Generation on Reliability of
More informationDesign and Control of Hybrid Power System for Stand-Alone Applications
Design and Control of Hybrid Power System for Stand-Alone Applications 1 Chanumalla Laxmi, 2 Manidhar Thula Abstract: This work presents design and controlling of photovoltaic fuel cell and super capacitor
More informationAvailable online at ScienceDirect. Procedia Engineering 137 (2016 ) GITSS2015
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 137 (2016 ) 244 251 GITSS2015 Simulation Analysis of Double Road Train Adaptability of Highway in China Hao Zhang a,b,*, Hong-wei
More informationIMPROVEMENT OF LOADABILITY IN DISTRIBUTION SYSTEM USING GENETIC ALGORITHM
IMPROVEMENT OF LOADABILITY IN DISTRIBUTION SYSTEM USING GENETIC ALGORITHM Mojtaba Nouri 1, Mahdi Bayat Mokhtari 2, Sohrab Mirsaeidi 3, Mohammad Reza Miveh 4 1 Department of Electrical Engineering, Saveh
More informationClark W Gellings, P.E. Fellow National Conference of State Legislators Energy Supply Task Force August 18, 2014
Clark W Gellings, P.E. Fellow National Conference of State Legislators Energy Supply Task Force August 18, 2014 2014 Electric Power Research Institute, Inc. All rights reserved. Electric Power Research
More informationMPPT Control System for PV Generation System with Mismatched Modules
Journal of Energy and Power Engineering 9 (2015) 83-90 doi: 10.17265/1934-8975/2015.01.010 D DAVID PUBLISHING MPPT Control System for PV Generation System with Mismatched Modules Chengyang Huang 1, Kazutaka
More informationImpact of electric vehicles on the IEEE 34 node distribution infrastructure
International Journal of Smart Grid and Clean Energy Impact of electric vehicles on the IEEE 34 node distribution infrastructure Zeming Jiang *, Laith Shalalfeh, Mohammed J. Beshir a Department of Electrical
More informationImpact Analysis of Fast Charging to Voltage Profile in PEA Distribution System by Monte Carlo Simulation
23 rd International Conference on Electricity Distribution Lyon, 15-18 June 215 Impact Analysis of Fast Charging to Voltage Profile in PEA Distribution System by Monte Carlo Simulation Bundit PEA-DA Provincial
More informationEnhancing the Voltage Profile in Distribution System with 40GW of Solar PV rooftop in Indian grid by 2022: A review
Enhancing the Voltage Profile in Distribution System with 40GW of Solar PV rooftop in Indian grid by 2022: A review P. Sivaraman Electrical Engineer TECh Engineering Services Agenda Introduction Objective
More informationDesign and Development of Bidirectional DC-DC Converter using coupled inductor with a battery SOC indication
Design and Development of Bidirectional DC-DC Converter using coupled inductor with a battery SOC indication Sangamesh Herurmath #1 and Dr. Dhanalakshmi *2 # BE,MTech, EEE, Dayananda Sagar institute of
More informationA Novel Approach for Optimal Location and Size of Distribution Generation Unit in Radial Distribution Systems Based on Load Centroid Method
A Novel Approach for Optimal Location and Size of Distribution Generation Unit in Radial Distribution Systems Based on Load Centroid Method G.Rajyalakshmi, N.Prema Kumar Abstract Optimum DG placement and
More informationOptimum Matching of Electric Vehicle Powertrain
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 88 (2016 ) 894 900 CUE2015-Applied Energy Symposium and Summit 2015: Low carbon cities and urban energy systems Optimum Matching
More informationA novel use of the hybrid energy storage system for primary frequency control in a microgrid
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 103 (2016 ) 82 87 Applied Energy Symposium and Forum, REM2016: Renewable Energy Integration with Mini/Microgrid, 19-21 April 2016,
More informationDesign Modeling and Simulation of Supervisor Control for Hybrid Power System
2013 First International Conference on Artificial Intelligence, Modelling & Simulation Design Modeling and Simulation of Supervisor Control for Hybrid Power System Vivek Venkobarao Bangalore Karnataka
More informationImpacts of distributed photovoltaic generation on Jenin distribution network: voltage level, power losses, power factor and power quality
Impacts of distributed photovoltaic generation on Jenin distribution network: voltage level, power losses, power factor and power quality Maher Jalal Khammash and Marwan Mahmoud Electrical Engineering
More informationIntelligent Control Algorithm for Distributed Battery Energy Storage Systems
International Journal of Engineering Works ISSN-p: 2521-2419 ISSN-e: 2409-2770 Vol. 5, Issue 12, PP. 252-259, December 2018 https:/// Intelligent Control Algorithm for Distributed Battery Energy Storage
More informationDevelopment of Novel Connection Control Method for Small Scale Solar - Wind Hybrid Power Plant
Development of Novel Connection Control Method for Small Scale Solar - Wind Hybrid Power Plant Vu Minh Phap*, N. Yamamura, M. Ishida, J. Hirai, K. Nakatani Department of Electrical and Electronic Engineering,
More informationPerformance Analysis of 40 KW Solar Photovoltaic System at DTU
International Journal of Research and Scientific Innovation (IJRSI) Volume III, Issue VI, June 216 ISSN 2321 275 Performance Analysis of 4 KW Solar Photovoltaic System at DTU Dr. R. S. Mishra 1, Dr. J.
More informationField Verification and Data Analysis of High PV Penetration Impacts on Distribution Systems
Field Verification and Data Analysis of High PV Penetration Impacts on Distribution Systems Farid Katiraei *, Barry Mather **, Ahmadreza Momeni *, Li Yu *, and Gerardo Sanchez * * Quanta Technology, Raleigh,
More informationElectric Vehicles Coordinated vs Uncoordinated Charging Impacts on Distribution Systems Performance
Electric Vehicles Coordinated vs Uncoordinated Charging Impacts on Distribution Systems Performance Ahmed R. Abul'Wafa 1, Aboul Fotouh El Garably 2, and Wael Abdelfattah 2 1 Faculty of Engineering, Ain
More informationDesign, simulation and construction of a Savonius wind rotor for subsidized houses in Mexico
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 57 (2014 ) 691 697 2013 ISES Solar World Congress Design, simulation and construction of a Savonius wind rotor for subsidized houses
More informationPower Balancing Under Transient and Steady State with SMES and PHEV Control
International Journal of Innovative Research in Electronics and Communications (IJIREC) Volume 1, Issue 8, November 2014, PP 32-39 ISSN 2349-4042 (Print) & ISSN 2349-4050 (Online) www.arcjournals.org Power
More informationProcedia - Social and Behavioral Sciences 195 ( 2015 ) World Conference on Technology, Innovation and Entrepreneurship
Available online at www.sciencedirect.com ScienceDirect Procedia - Social and Behavioral Sciences 195 ( 2015 ) 2586 2591 World Conference on Technology, Innovation and Entrepreneurship Application of Finite
More informationOPTIMUM ALLOCATION OF DISTRIBUTED GENERATION BY LOAD FLOW ANALYSIS METHOD: A CASE STUDY
OPTIMUM ALLOCATION OF DISTRIBUTED GENERATION BY LOAD FLOW ANALYSIS METHOD: A CASE STUDY Wasim Nidgundi 1, Dinesh Ballullaya 2, Mohammad Yunus M Hakim 3 1 PG student, Department of Electrical & Electronics,
More informationModeling and Comparison of Dynamics of AC and DC Coupled Remote Hybrid Power Systems
Modeling and Comparison of Dynamics of AC and DC Coupled Remote Hybrid Power Systems Presenter: Tanjila Haque Supervisor : Dr. Tariq Iqbal Faculty of Engineering and Applied Science Memorial University
More informationMethodology for renewable power generation and optimization of hybrid solar / wind power system using IEEE load pattern
Methodology for renewable power generation and optimization of hybrid solar / wind power system using IEEE load pattern Ujwala V. Waghmare Department of Electrical engineering YCCE,Nagpur,Maharashtra,India
More informationRecent trends and Importance of Power Electronics: Dr. Siva Kumar K IIT Hyderabad
Recent trends and Importance of Power Electronics: Dr. Siva Kumar K IIT Hyderabad Need for going towards renewable energy sources: Fossil-fuel exhaustion environmental problems caused by conventional power
More informationVoltage Index Method for Optimal Allocation of DG Units in a Distribution system to improve the Voltage Stability Margin
Voltage Index Method for Optimal Allocation of DG Units in a Distribution system to improve the Voltage Stability Margin S.Sravanthi 1, B.Praveena 2 1 PG Scholar, Department of EEE, JNTU Anantapur, Andhra
More informationDecentralized Battery Energy Management for Stand-Alone PV- Battery Systems
Decentralized Battery Energy Management for Stand-Alone PV- Battery Systems Umarin Sangpanich (PhD.) Faculty of Engineering at Sriracha Kasetsart University (Sriracha campus) 19 May 2016 Outline A key
More informationCharacterization of Voltage Rise Issue due to Distributed Solar PV Penetration
Characterization of Voltage Rise Issue due to Distributed Solar PV Penetration Abdullah T. Alshaikh, Thamer Alquthami, Sreerama Kumar R. Department of Electrical and Computer Engineering, King Abdulaziz
More informationAvailable online at ScienceDirect. Procedia Engineering 68 (2013 ) 70 76
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 68 (2013 ) 70 76 Malaysian International Tribology Conference 2013 (MITC2013) The Effects of Oil Supply Pressure at Different
More informationAn approach for estimation of optimal energy flows in battery storage devices for electric vehicles in the smart grid
An approach for estimation of optimal energy flows in battery storage devices for electric vehicles in the smart grid Gergana Vacheva 1,*, Hristiyan Kanchev 1, Nikolay Hinov 1 and Rad Stanev 2 1 Technical
More informationOptimization of PID Parameters of Hydraulic System of Elevating Wheelchair Based on AMESim Hui Cao a*, Hui Guo b
Available online at www.sciencedirect.com Procedia Engineering 15 (2011) 3710 3714 Advanced in Control Engineering and Information Science Optimization of PID Parameters of Hydraulic System of Elevating
More informationDesign and Implementation of Reactive Power with Multi Mode Control for Solar Photovoltaic Inverter in Low Voltage Distribution System
Design and Implementation of Reactive Power with Multi Mode Control for Solar Photovoltaic Inverter in Low Voltage Distribution System K.Sudhapriya 1, S.Preethi 2, M.Ejas Ahamed 3 PG Scholar 1,2,3 Department
More informationA.Arun 1, M.Porkodi 2 1 PG student, 2 Associate Professor. Department of Electrical Engineering, Sona College of Technology, Salem, India
A novel anti-islanding technique in a Distributed generation systems A.Arun 1, M.Porkodi 2 1 PG student, 2 Associate Professor Department of Electrical Engineering, Sona College of Technology, Salem, India
More informationMuti-objective topology optimization of an electric vehicle s traction battery enclosure
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 88 (2016 ) 874 880 CUE2015-Applied Energy Symposium and Summit 2015: Low carbon cities and urban energy systems Muti-objective topology
More informationDISTRIBUTED GENERATION FROM SMALL HYDRO PLANTS. A CASE STUDY OF THE IMPACTS ON THE POWER DISTRIBUTION NETWORK.
DISTRIBUTED GENERATION FROM SMALL HYDRO PLANTS. A CASE STUDY OF THE IMPACTS ON THE POWER DISTRIBUTION NETWORK. N. Lettas*, A. Dagoumas*, G. Papagiannis*, P. Dokopoulos*, A. Zafirakis**, S. Fachouridis**,
More informationBehaviour of battery energy storage system with PV
IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. Issue 9, September 015. ISSN 348 7968 Behaviour of battery energy storage system with PV Satyendra Vishwakarma, Student
More informationSmart Home Renewable Energy Management System
Available online at www.sciencedirect.com Energy Procedia 12 (2011) 120 126 ICSGCE 2011: 27 30 September 2011, Chengdu, China Smart Home Renewable Energy Management System A. R. Al-Ali *, Ayman El-Hag,
More informationINSTALLATION OF CAPACITOR BANK IN 132/11 KV SUBSTATION FOR PARING DOWN OF LOAD CURRENT
INSTALLATION OF CAPACITOR BANK IN 132/11 KV SUBSTATION FOR PARING DOWN OF LOAD CURRENT Prof. Chandrashekhar Sakode 1, Vicky R. Khode 2, Harshal R. Malokar 3, Sanket S. Hate 4, Vinay H. Nasre 5, Ashish
More informationControl Strategies for Supply Reliability of Microgrid
Control Strategies for Supply Reliability of Microgrid K. M. Sathya Priya, Dept. of EEE Gvpcoe (A), Visakhapatnam. K. Durga Malleswara Rao Dept. of EEE GVPCOE (A), Visakhapatnam. Abstract-- Maintaining
More information*Author for Correspondence
OPTIMAL PLACEMENT OF VARIOUS TYPES OF DISTRIBUTED GENERATION (DG) SOURCES IN RADIAL DISTRIBUTION NETWORKS USING IMPERIALIST COMPETITIVE ALGORITHM (ICA) Hadi Abbasi,2 and * Mahmood Ghanbari 2 Department
More informationInternational Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)
Modeling and Control of Quasi Z-Source Inverter for Advanced Power Conditioning Of Renewable Energy Systems C.Dinakaran 1, Abhimanyu Bhimarjun Panthee 2, Prof.K.Eswaramma 3 PG Scholar (PE&ED), Department
More informationBIDIRECTIONAL DC-DC CONVERTER FOR INTEGRATION OF BATTERY ENERGY STORAGE SYSTEM WITH DC GRID
BIDIRECTIONAL DC-DC CONVERTER FOR INTEGRATION OF BATTERY ENERGY STORAGE SYSTEM WITH DC GRID 1 SUNNY KUMAR, 2 MAHESWARAPU SYDULU Department of electrical engineering National institute of technology Warangal,
More informationExperimental Study on Inlet Structure of the Rod Pump with Down-hole Oil-water Hydrocyclone
Available online at www.sciencedirect.com Procedia Engineering 18 (2011) 369 374 The Second SREE Conference on Oil and Gas Engineering Experimental Study on Inlet Structure of the Rod Pump with Down-hole
More informationOptimal sizing and Placement of Capacitors for Loss Minimization In 33-Bus Radial Distribution System Using Genetic Algorithm in MATLAB Environment
Optimal sizing and Placement of Capacitors for Loss Minimization In 33-Bus Radial Distribution System Using Genetic Algorithm in MATLAB Environment Mr. Manish Gupta, Dr. Balwinder Singh Surjan Abstract
More informationSimulation and design of wind-pv hybrid power generation systems
Simulation and design of wind-pv hybrid power generation systems Anumeha Awasthi 1, Kuldeep Sahay 2, Anuj Kumar Yadav 3 1 EEE Department RIETK, 2 EEE Department IET Lucknow, 3 CSE Department NITH, INDIA
More informationAn Optimization Model of EVs Charging and Discharging for Power System Demand Leveling
Journal of Mechanics Engineering and Automation 7 (2017) 243-254 doi: 10.17265/2159-5275/2017.05.001 D DAVID PUBLISHING An Optimization Model of EVs Charging and Discharging for Power System Demand Leveling
More informationPower Management with Solar PV in Grid-connected and Stand-alone Modes
Power Management with Solar PV in Grid-connected and Stand-alone Modes Sushilkumar Fefar, Ravi Prajapati, and Amit K. Singh Department of Electrical Engineering Institute of Infrastructure Technology Research
More informationCOMPARISON OF SOLAR TRACKING WITH FIXED PANEL POWER GENERATION (WITHOUT LOAD)
http:// COMPARISON OF SOLAR TRACKING WITH FIXED PANEL POWER GENERATION (WITHOUT LOAD) Navalgund Akkamahadevi 1, Dr. P. P Revenkar 2, Sanath Kumar T.P 3 1,2 Department of Energy System Engineering, BVBCET
More informationDesign of Three Input Buck-Boost DC-DC Converter with Constant input voltage and Variable duty ratio using MATLAB/Simulink
Design of Three Input Buck-Boost DC-DC Converter with Constant input voltage and Variable duty ratio using MATLAB/Simulink A.Thiyagarajan, B.Gokulavasan Abstract Nowadays DC-DC converter is mostly used
More informationModeling Distribution System Impacts of Solar Variability and Interconnection Location
Modeling Distribution System Impacts of Solar Variability and Interconnection Location Photos placed in horizontal position with even amount of white space between photos and header Matthew J. Reno 1,2,
More informationOPTIMIZATION OF SOLAR-WIND-DIESEL HYBRID POWER SYSTEM DESIGN USING HOMER. I. A. Wibowo *, and D.Sebayang
OPTIMIZATION OF SOLAR-WIND-DIESEL HYBRID POWER SYSTEM DESIGN USING HOMER I. A. Wibowo *, and D.Sebayang Department of Mechanical Engineering, Faculty of Engineering, Mercu Buana University Indonesia Abstract
More informationReal-Time Simulation of A Modular Multilevel Converter Based Hybrid Energy Storage System
Real-Time Simulation of A Modular Multilevel Converter Based Hybrid Energy Storage System Feng Guo, PhD NEC Laboratories America, Inc. Cupertino, CA 5/13/2015 Outline Introduction Proposed MMC for Hybrid
More informationDesign of Active and Reactive Power Control of Grid Tied Photovoltaics
IJCTA, 9(39), 2016, pp. 187-195 International Science Press Closed Loop Control of Soft Switched Forward Converter Using Intelligent Controller 187 Design of Active and Reactive Power Control of Grid Tied
More informationA Novel GUI Modeled Fuzzy Logic Controller for a Solar Powered Energy Utilization Scheme
1 A Novel GUI Modeled Fuzzy Logic Controller for a Solar Powered Energy Utilization Scheme I. H. Altas 1, * and A.M. Sharaf 2 ihaltas@altas.org and sharaf@unb.ca 1 : Dept. of Electrical and Electronics
More informationDesign and Installation of A 20.1 kwp Photovoltaic-Wind Power System
Mindanao Journal of Science and Technology Vol. 13 (2015) 228-237 Design and Installation of A 20.1 kwp Photovoltaic-Wind Power System Ambrosio B. Cultura II * and Maricel C. Dalde College of Engineering
More informationReliability Analysis of Radial Distribution Networks with Cost Considerations
I J C T A, 10(5) 2017, pp. 427-437 International Science Press Reliability Analysis of Radial Distribution Networks with Cost Considerations K. Guru Prasad *, J. Sreenivasulu **, V. Sankar *** and P. Srinivasa
More informationCASE STUDY OF POWER QUALITY IMPROVEMENT IN DISTRIBUTION NETWORK USING RENEWABLE ENERGY SYSTEM
CASE STUDY OF POWER QUALITY IMPROVEMENT IN DISTRIBUTION NETWORK USING RENEWABLE ENERGY SYSTEM Jancy Rani.M 1, K.Elangovan 2, Sheela Rani.T 3 1 P.G Scholar, Department of EEE, J.J.College engineering Technology,
More informationDesign and Analysis of Hybrid Renewable Microgrid Systems for United Nations WFP Humanitarian Locations in Developing Countries
Design and Analysis of Hybrid Renewable Microgrid Systems for United Nations WFP Humanitarian Locations in Developing Countries Denim D Dcosta MSPE Master s Thesis Exposé Supervisor: Prof. Dr.-Ing. Ulrich
More informationComputer Aided Transient Stability Analysis
Journal of Computer Science 3 (3): 149-153, 2007 ISSN 1549-3636 2007 Science Publications Corresponding Author: Computer Aided Transient Stability Analysis Nihad M. Al-Rawi, Afaneen Anwar and Ahmed Muhsin
More informationAssessing Feeder Hosting Capacity for Distributed Generation Integration
21, rue d Artois, F-75008 PARIS CIGRE US National Committee http : //www.cigre.org 2015 Grid of the Future Symposium Assessing Feeder Hosting Capacity for Distributed Generation Integration D. APOSTOLOPOULOU*,
More informationAnalysis of Variability of Solar Panels in The Distribution System
Analysis of ariability of Solar Panels in The Distribution System Tatianne Da Silva Jonathan Devadason Dr. Hector Pulgar-Painemal College of Electrical Engineering Research Assistant Assistant Professor
More informationCombination control for photovoltaic-battery-diesel hybrid micro grid system
, pp.93-99 http://dx.doi.org/10.14257/astl.2015.82.18 Combination control for photovoltaic-battery-diesel hybrid micro grid system Yuanzhuo Du 1, Jinsong Liu 2 1 Shenyang Institute of Engineering, Shenyang,
More informationSmart Operation for AC Distribution Infrastructure Involving Hybrid Renewable Energy Sources
Milano (Italy) August 28 - September 2, 211 Smart Operation for AC Distribution Infrastructure Involving Hybrid Renewable Energy Sources Ahmed A Mohamed, Mohamed A Elshaer and Osama A Mohammed Energy Systems
More informationAvailable online at ScienceDirect. Procedia Engineering 150 (2016 )
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 150 (2016 ) 1245 1251 International Conference on Industrial Engineering, ICIE 2016 Analysis of Possible Dynamic Vibration Dampers
More information