Winning Bid US Petroleum Equipment Walts Petroleum Northwest Petroleum Petro-Chemical Systems Kimberly Green Bay Wausau Fond Du Lac

Similar documents
SECTION VEHICLE FUEL DISPENSING EQUIPMENT

General information about underground storage tank (UST) fueling systems in every day language.

Aboveground Tank Equipment. Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co.

Code Requirements on Aboveground Storage Tanks Dispensing Fuels At Motor Vehicle Fuel-Dispensing Stations

ADDENDUM #1. A. Alternate Bid Item #3A - The procurement and installation of a new 12,000 gallon UL 2085 rated AGT tank for

New UST Installation Inspection Checklist

Fuel Storage Dec 2016

Earthsafe Systems, Inc. Emergency Power Fuel Systems Recommended System Standard

Leak Detector, Red Jacket #FX1V

ADDENDUM No. 8 TO THE CONTRACT DOCUMENTS

PEI/RP Recommended Practices for Installation of Bulk Storage Plants

NOW UL LISTED. Patented

INSTALLATION INSTRUCTIONS B-375-D Fiberglass DoubleWall Spill Bucket

Application for Permit to Install Underground Storage Tanks (Petroleum or Hazardous Substances) 1. Owner Information 2. Installation Site Information

GASBOY FLEET & COMMERCIAL

SECTION FUEL-OIL DISTRIBUTION (APPLIES TO FUEL TANKS FOR GENERATORS)

ANNUAL UST SYSTEM INSPECTION CHECKLIST

ADDENDUM NO. #1 ITB # FLORIDA A&M UNIVERSITY (FAMU) FUEL STORAGE TANK INSPECTIONS December 8, 2017

DESIGNER SUPPLEMENTAL INSTRUCTIONS DSI NO. MCA-DSI-0018

TRADE EXPERIENCE LOG BOOK CANADIAN PETROLEUM CONTRACTORS ASSOCIATION. Petroleum Mechanic Training & Certification

PREPACKAGED AVIATION FUEL TANKS AND EQUIPMENT CITY OF HORNELL, NEW YORK 82 MAIN STREET HORNELL, NEW YORK 14843

Fire & Rescue District

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

DEFENDER SERIES. 5 Gallon, Single Walled, Field Replaceable Spill Container Fiberglass Model Series INSTALLATION, OPERATION, & MAINTENANCE

9.21 Tank Program Guide NYS Office of Mental Health Tank System Installation Guide

FINAL UNDERGROUND STORAGE TANK RULE CHANGES. Heather Peters UST Compliance and Technology Unit

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

CONTENTS. Foreword...iii. 1. Introduction...1

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS

FUEL DISPENSING SYSTEMS SE-47. Component Details. 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System

Tank Filling Systems. for Petroleum Products

APPLICATION for BUSINESS LICENSE Licensing & Permits City of Williston PO Box 1306, Williston, ND

Test Date: 3/30/2018 Order Number: Dear Regulator, Enclosed are the results of recent testing performed at the following facility:

SAN ANTONIO WATER SYSTEM P. O. BOX 2449 SAN ANTONIO, TEXAS TABULATION OF BIDS

PROJECT: Springhill & Canal Development (1950 E. Springhill Drive, Terre Haute, IN 47802)

APPENDIX B. DYNAMIC PRESSURE PERFORMANCE TEST (taken from BAAQMD test procedure ST-27)

Provide the following information: Site Address: City: Zip: Project Contact Name: Phone No.: ( ) ext.

County of Yolo UNDERGROUND STORAGE TANK PROGRAM INSTALLATION/MODIFICATION/REPAIR APPLICATION

Underground Storage Tank Annual Compliance Inspection (Revised 1/2015)

Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD

CONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR

ADDENDUM NUMBER 2 (DATED May 7, 2012) TO THE CONTRACT DOCUMENTS AND CONSTRUCTION SPECIFICATIONS FOR WINDSOR CRUDE OIL TERMINAL

Tank Filling Systems for Petroleum Products

Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS

PEI/RP Recommended Practices for the Inspection and Maintenance of UST Systems

Changes to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC

Septic Tanks. Effluent Screen Cleaning. Effluent Screens. Surveying Abbreviations. Installation Keys. Septic Tanks, Holding Tanks & Pump Tanks

Installation & Maintenance Manual Green Machine PMC / ISD California

FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System

FUEL DISPENSING SYSTEMS SE-37. Component Details. 120V AC - 20 GPM Metered Tank-top Dispensing System

Stage I Vapor Recovery Testing

Removal of Underground Storage Tanks (UST) Encountered during Construction

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017

ER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products (VR-402-D) Single Wall Tank with Top Fill. 12 or 34. Pressure Vacuum Vent

Installation Manual ECS Membrane Processor: PMC and ISD

(Please type or use black ink)

Lorri Grainawi Steel Tank Institute. PA NISTM April 25, 2013 Harrisburg, PA

DEF Storage & Dispensing Equipment Price Catalog. Specialty Tanks. Turn-Key Systems Dispensers Mini-Bulk Tanks Bulk Tanks

40 CFR 63, Subpart CCCCCC

Earthsafe Systems, Inc. Page 1

Changes to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC

NYSDEC CBS Compliance Requirements

Ohio EPA. Division of Air Pollution Control. Engineering Guide #12

OPW Installation and Maintenance Instructions OPW Series Primary and Secondary Bucket Replacement Instructions

Enhanced Vapor Recovery and In-Station Diagnostics. Presented by: Matthew Schuessler, N Cal Territory Mgr 1

Understanding the Colorado Annual Compliance Package. William Holman & Robert Schlegel Inspectors Division of Oil and Public Safety

Frequent Mishaps and Solutions with Regulated Underground Storage Tanks in Pennsylvania


Jet Fuel Quality Control Inspection Checklist INSPECTION SIGNATURES INSPECTION CHECKLIST

Phase-Two Water Detector

The Better Dispensers by Bergquist

.4 Emergency and normal vents and terminations. .1 CAN/CSA-B139-09, Installation Code for Oil Burning Equipment.

MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES

3) Storage at construction sites for refueling construction equipment; or. 4) Storage at airports as addressed in Section of this Part.

Dispenser Containment Manual. Product Manual * Publication Number: DCM-0001 * Issue Date: 05/27/09 Supercedes: 11/01/07

WSB clean: Installation Manual

Underground Storage Tank Guidance for Commercial Building Inspectors

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual

OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF AST S AN OVERVIEW OF ABOVEGROUND STORAGE TANK REQUIREMENTS

Specification Sheet Form Rev

North Carolina Department of Environment and Natural Resources Division of Waste Management Underground Storage Tank Section

DEFENDER SERIES BELOW GRADE DOUBLE WALL SPILL CONTAINER INSTALLATION GUIDE

PENNSYLVANIA ABOVE GROUND STORAGE TANKS

This handbook is provided as a general guide. assistance/content/storage-tank-compliance

Fuel Systems GASOLINE FUEL SYSTEMS

Compliance Strategies and Benefits. Brian Derge Tanknology Inc. December 6, 2012

E. Section , Environmental Monitoring and Fuel Control System

Inspector's Initials: Tank Owner or Agent Signature: Title: Date:

COMPLIANCE WITH THIS PUBLICATION IS MANDATORY

Storage Tank Systems for Petroleum Products and Allied Petroleum Products Regulations

ER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products 8 5 (VR-402-B) Single Wall Tank with Top Fill. 26 Alarm. Pressure Vacuum Vent

Request For Bids. Sewer Cleaning Truck

PROCEDURE FOR THE HANDLING OF FUEL ON CONSTRUCTION SITES. Civil Engineering Sector Labour-Management Health and Safety Committee

P.O. Box 435 Saratoga Springs, NY 12866

MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES

Environment Canada (EC) Storage Tank System Identification Form

PUBLIC WORKS AND SERVICES PETROLEUM PRODUCTS DIVISION STANDARD DETAILED DRAWINGS FOR NORTHERN FUEL STORAGE AND DISTRIBUTION FACILITIES

KENDALL COUNTY HIGHWAY DEPARTMENT

New Tank Installations. Peter Rollo

Transcription:

Minimum Specifications/Questionnaire Bid Results for One (1) New Fuel Dispensing System-Larrabee Shop Winning Bid PERMIT FEES, FORMS, PLANS and NOTIFICATIONS Secure all necessary state and local permits for entire project including removal and disposal of old underground tanks, and complete installation of new above ground system, including canopy. Yes Yes Did not complete bid questionnaire Yes Notification to inspectors, and completion of required paperwork. Yes Yes Yes Draft a SPCC plan Yes Yes Yes REMOVAL & DISPOSAL Remove and dispose existing dispensers and concrete, and light fixture. Yes Yes Yes Remove and dispose existing below ground 10,000 gallon, single wall, fiberglass tank and plumbing. Yes Yes Yes Provide at least two (2) 55 gallon drums for disposal of non-hazardous in-tank sludge disposal. Disposal and cost is bidders responsibility Yes $230 per additional drum Yes $125 per additional drum Yes $475 per add. drum Specify cost of additional drums Backfill site to grade, providing 12 gravel top base, and compact Yes Yes Yes Provide assessment and documentation of soil contamination and Guidance. Yes Yes Yes Disconnect existing Fuel Master terminal and save for installation on new fueling system. Yes Yes Yes INSTALLATION Unload and set one (1) 12,000 gallon and one (1) 5,000 gallon aboveground double wall UL-142 tanks. Yes Yes Yes Install new above ground tanks. Yes Yes Yes Provide labor, tools, and equipment to plumb and install all proposed equipment. Yes Yes Yes Provide and install all necessary decals. Yes Yes Yes Setup, startup, testing, and calibration of equipment. Yes Yes Yes Perform tank and line tests using tank monitor. No Visual Monitor Yes No There is no tank monitor Furnish and install (1) fire extinguisher with cabinet. Yes Yes Yes Train owner on proper equipment use and maintenance. Yes Yes Yes Submit warranty paperwork to manufacturers. Yes Yes Yes Install existing Fuel Master terminal. Change terminal configuration from a single product dual dispenser, to a dual product, dual dispenser. Yes Yes Yes 1

ABOVE GROUND TANKS (AST) One (1) 12,000 gallon UL142 double wall vertical tank 12 diameter 14 tall, painted white, including ladder, railing, or any fall protection for tank top inspections, securable to prevent unauthorized access. (Diesel) Yes Yes Yes One (1) 5,000 gallon UL142 double wall vertical tank 9 diameter 10 6 tall, painted white, including ladder, railing, or any fall protection for tank top inspections, securable to prevent unauthorized access. (Gas) Yes Yes Yes GASBOY DISPENSING EQUIPMENT Two (2) Gasboy commercial 9853KXTW1 electric twin dispenser, (2) product (Diesel and No-Lead) side load, standard flow single pulse unit. Black top and sides with white doors. Yes Yes No Make and Model of dispensers Gasboy 9853KXTW2 Bennett 3722-SNR Specify dispenser warranty 1yr parts & labor-additional 5yr avail. 1 year Include No Smoking, Stop Engine, and Octane decals Yes Yes Yes EMERGENCY VALVES 2 Double poppet emergency valves Yes Yes Yes GAS HOSES, NOZZLES, SWIVELS Two (2) ¾ Automatic nozzles, breakaway connectors, swivel connectors, and 5/8 x 8-1/2 hoses. Yes Yes Yes DIESEL HOSES, NOZZLES, SWIVELS Two (2) 1 Automatic nozzles, breakaway connectors, swivel connectors, and 1 x 18 hoses. Yes Yes Yes Two (2) High hose retractors which include a hose bun, cables, base and Clamp for hose. Yes Yes Yes CENTERON TANK LEVEL MONITOR Remove existing Veeder Root TLS350 unit and probes Yes Yes Yes Install new tank radar level sensor and analog controller Yes Yes Yes Provide 500 analog calls Yes Yes Left line item blank Set up online monitoring to coincide with our existing New London site Which also uses Centeron system Yes Yes Yes SUBMERSIBLE EQUIPMENT One (1) 1 1/2 H.P. Red Jacket submersible pumps for diesel. Yes Yes Yes One (1) ¾ H.P. Red Jacket submersible pump for No-Lead Yes Yes Yes 2

CANOPY Erection of a four post canopy (45 x 15 ) to cover dispensing equipment and vehicles at dispensers. Clearence 15 6. Subset 1 6 Yes Yes Yes Canopy to include three (3) LED lights with photo eye. Yes Yes Yes Loads per state and local codes. Yes Yes Yes Footings installed per canopy specifications/state and local code Yes Yes Yes Includes all state and local permits Yes Yes Yes External downspouts, draining canopy to the surface Yes Yes Yes Width spacing 3, 9, 3 Yes Yes Yes Length spacing 15, 15, 15 Yes Yes Yes CONCRETE and CRASH PROTECTION One (1) concrete tank pad to support vertical tank system and equipment. 20 x 54 x 8 thick Yes Yes Yes Tank pad forms must be set at an elevation of 0.2 feet less than Designated benchmark marked with pink paint on the LR corner of the Scale platform as viewed from the road. After forms are set, prior to pouring concrete, proper elevation must be verified by Highway Dept. personnel. 24 hours prior notice of setting forms must be given. Yes Yes Yes Two (2) concrete fueling pads, 15 x 54 x 8 thick. Yes Yes Yes Fueling pads must a maximum of 1 percent slope down and away from Center tank pad. Yes Yes Yes Twenty six (26) 6 guard posts to protect equipment. Yes Yes Yes 16 W x 30 L x 6 H cyclone security fence with one (1) 3 wide lockable gate to secure tanks and fill box. Yes Yes Yes ELECTRICAL Two (2) Dispensers Yes Yes Yes Two (2) Submersibles Yes Yes Yes Two (2) Solenoid Valves Yes Yes Yes One (1) Card System Yes Yes No Removed in Spec One (1) Tank Level Monitor Yes Yes No Removed in Spec Two (2) Probes Yes Yes No Removed in Spec One (1) Overfill Alarm(s) & Acknowledgement Switch Yes Yes Yes Three (3) Canopy Lights Yes Yes Yes One (1) Emergency Shut Off Switch Yes Yes Yes 3

TANK EQUIPMENT and PIPING Two (2) 15 gallon ground level spill containers, 3 ball valve, 3 sing check valve, 3 male cam adaptor, and 3 fill cap. No 1 Fill for Both Yes Yes Two (2) Morrison #9095 3300AV 3 overfill valve or comparable. Yes Model 9095A Yes Yes Two (2) Morrison #419 3 aluminum drop tube or comparable. Yes Model 419 Yes Yes One (1) 3 Updraft vent and riser pipe. Yes Yes Yes One (1) 3 Pressure vacuum vent and riser pipe. Yes Yes Yes Four (4) 8 Emergency vents. Yes Yes Yes Two (2) OPW 200TG mechanical tank gauge or Two (2) Morrison #710 1-1/2 Anti-siphon solenoid valve or Two (2) OPW TGTA-0400 4 Tank bung gauge/alarm combo fitting or Two (2) OPW 44TA-LLFS 36 Liquid-Level float switch or One (1) OPW 444TA-0100 Four signal tank alarm or 3 Schedule 40 black pipe for product fill. Yes Yes Yes 2 Schedule 40 black pipe for product supply. Yes Yes Yes One (1) Aluminum emergency pump shut-off sign. Yes Yes Yes One (1) Aluminum tank alarm sign Yes Yes Yes Set of NFPA 704 and tank ID decals as required. Yes Yes Yes 4

PRICE PROPOSAL Permits and fees $5,325 $2,650 includes spec draft $1,450 $5,800 Removal and Disposal $10,050 $12,605.33 incl. $1460.22 site assessment $13,308.89 $9,500 Installation $13,600 $18,610 $36,500 $44,500 Tanks $38,400 $38.188.88 $37,488 $40,000 Dispensing Equipment $15,825 $13,602.24 $14,726 $15,450 Tank Level Monitor Equip. $2,800 $1,745 $4,318.48 $2,000 Submersible Equipment $3,025 $4242 $5,619.25 $4,000 Excavation and Concrete $23,525 $24,611.11 $28,742.50 $42,600 Electrical $13,100 $12,444 $12,583.23 $20,000 Tank Equipment and Piping $12,550 $23,816.07 $20,748.11 $55,950 Canopy & Lights $29,600 $22,613.88 $22,750.88 Other -$900 Trade in dispensers/tank monitor TOTAL BID COST $166,900 $175,128.51 $198,236.22 $239,800 PROJECT COMPLETION DATE: 90 days from award date June 1, 2016 No Date June 15, 2016 5