MULTIPULSE PISTON POSITIVE DISPLACEMENT FLOWMETER

Similar documents
MULTIPULSE SAP SUPER ACID PROOF POSITIVE DISPLACEMENT FLOWMETER

QUALITY INDUSTRIAL FLOWMETERS

OM SERIES OVAL GEAR METERS. OM SERIES Oval Gear Meters

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

OVAL GEAR Medium capacity positive displacement flowmeters

MULTIPULSE PISTON POSITIVE DISPLACEMENT FLOWMETER

MULTIPULSE PISTON POSITIVE DISPLACEMENT FLOWMETER

BI-DIRECTIONAL INSERTION METER

OM004, OM006 & OM008 Oval Gear Meter

OVAL GEAR Medium capacity positive displacement flowmeter

RUN ACCUM. TOTAL STOP BAT LOW HIGH

I N S T R U C T I O N M A N U A L

Trimec Flow Products Pty. Ltd. Tel : /51 Kalman Drive, Fax : Effective : August 2013

OVAL GEAR. Medium capacity positive displacement Pulse flowmeters I N S T R U C T I O N M A N U A L

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

I N S T R U C T I O N M A N U A L

I N S T R U C T I O N M A N U A L 3 (080), 3 (080E), 4 (100), & 4 (100E)

OVAL GEAR Medium capacity positive displacement pulse flowmeter. Size : ½ ( 015mm)

QUALITY INDUSTRIAL FLOWMETERS

DUALPULSE BI-DIRECTIONAL INSERTION FLOW TRANSDUCER INSTRUCTION MANUAL IMDP DUALPULSE LOCK

OVAL GEAR Medium capacity positive displacement Mechanical flowmeters. Model: ½ (15m m)

I N S T R U C T I O N M A N U A L

OVAL GEAR. Large Capacity Positive Displacement Mechanical Flowmeters. Models: 3 (D-750), 3 (D-1000), 4 (D-1500) & 4" (D-2500)

POSITIVE DISPLACEMENT FLOWMETER I N S T R U C T I O N M A N U A L

Positive displacement flowmeter for continuous flow measurement

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

QUALITY INDUSTRIAL FLOWMETERS

OVAL GEAR. Medium Capacity Positive Displacement Mechanical Flowmeters. Models: 1 (D-150), 1½ (D-250), 2 (D-450) & 2" (D-580)

MX-SERIES OVAL GEAR FLOW METERS

DOR Insertion Paddle Wheel Flowmeter

I N S T R U C T I O N M A N U A L

PSF50 Paddle flow switch

DRT. Ring Piston Flow Meter. for low/high Viscous Liquids

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

Positive Displacement Flowmeters GM020 series instruction manual

Positive Displacement Flowmeters GM007 series instruction manual

IM SERIES BI-DIRECTIONAL INSERTION FLOWMETER. Instruction Manual. To the owner SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

POSITIVE DISPLACEMENT FLOWMETERS

INSTALLATION AND OPERATION

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

DOR. Insertion Paddle Wheel Flow Meter / Monitor. for Low Viscosity Liquids

Operating Instructions for Oval Wheel Flowmeter. Model: DOE

macnaught flow measurement

INSTRUCTION MANUAL MN7 series

INDUSTRIAL DYNAMICS CO

INSERTION flow sensor for continuous flow measurement

G2 Industrial Grade Meters

macnaught flow measurement

A1 Commercial Grade Meters

FPD1001B thru FPD1003B, FPD1102B and FPD1103B, FPD1201B thru FPD1203B SERIES LOW FLOW Positive Displacement Flowmeters

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

macnaught flow measurement

A1 Commercial Grade Meters

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Positive Displacement Flowmeters GM020 series instruction manual

The experts in fluid technology

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

RPFS. ROTA PULSE FLOW SENSOR (Slip Insertion Paddlewheel) DATASHEET FEATURES

The experts in fluid handling

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

POSITIVE DISPLACEMENT FLOW METERS

OVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 )

FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters

POSITIVE DISPLACEMENT FLOW METERS

MX06 - MX100 OVAL GEAR FLOWMETER SERIES

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

TYPE MP OSCILLATING PISTON FLOWMETER

WATER & IRRIGATION METERS QUALITY FLOW METERS FOR THE AGRICULTURE AND AQUIFER MANAGEMENT. Quality Engineered Systems

IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL

MX06 - MX100 OVAL GEAR FLOWMETER SERIES APPROVED FOR USE IN HAZARDOUS AREAS

OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1

Positive Displacement Flowmeters GM50 series instruction manual

Flow Sensors & Instruments

MODEL MX12 1/2 OVAL GEAR FLOWMETER

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

25 mm (1 in), 38 mm (1-1/2 in) & 50 mm (2 in) TYPE S FLOWMETERS WITH MODEL 157 AND 800 SERIES REGISTERS

Turbine flowmeters Series TM

MODEL MX75 3 OVAL GEAR FLOWMETER

PRECISION METERS & ACCESSORIES

Inline Ultrasonic Flowmeter

POSITIVE DISPLACEMENT FLOWMETER

Flow Meter Product Catalogue. JSG Industrial Systems quality industry solutions. Fire Extinguisher & Suppression Systems. Flow Measurement Systems

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Industrial OG meter series IOG Inline and flanged oval gear meter

For any information please contact: ASCO Pompe srl Control Division Tel.: (+39 02) (switchboard) Fax: (+39 02)

DOR. Insertion Paddle Wheel Flow Meter/Monitor. for Low Viscous Liquids. Flow range: l/s to l/s. Flow velocity range: 0.

INDUSTRIAL METER CATALOG version seven

Metal tube variable area flowmeter for gases, liquids and steam

Electromagnetic Flow Monitor magphant

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Variable Area Flowmeters Ori-Flowrator TM Meters

KDM ARMORED FLOW METER & SWITCH

PA - Turbine Flowmeter Range

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

High Performance Turbine Technology

유량계전문제조업체. Electro Magnetic FLOWMETER

Transcription:

MULTIPULSE PISTON POSITIVE DISPLCEMENT FLOWMETER models : MP015 MP025 MP040 MP050 TRIMEC INDUSTRIES Pty.Ltd. 1 / 19 Northumberland Road Caringbah NSW 2229 Sydney - USTRLI Tel : +61 2 9540 4433 Fax: +61 2 9525 9411 Email : sales@trimecind.com.au Website: www.trimecind.com Distributed by: INSTRUCTION MNUL TRIMEC Europe Ltd Floor 3, 5 Boltro Road Haywards Heath West Sussex, UNITED KINGDOM RH16 1BP Tel : +44 144-441-7880 Fax : +44 144-441-7668 Email : europe@trimecind.com Website : www.trimecind.com TRIMEC Inc. 916 Belcher Drive Pelham, L 35124 US Tel : +1 205 378 1050 Fax : +1 205 685 3001 Email : customerservice@trimecus.com Website : www.trimecind.com IMMP000-4106

1 Each meter has been calibrated on mineral oil and will contain a small amount of oil residue. The oil used is Castrol Diesel Calibration Fluid 4113 (product code 055830). I M P O R T N T CONTENTS Page 1.0 OVERVIEW 2 1.1 Model number designation 3 1.2 Specifications 4 1.3 Operating principle 5 2.0 INSTLLTION 6 2.1 Orientation 6 2.2 Meter location 6 2.3 By-pass installation 6 2.4 Strainers 6 2.5 Commissioning 7 2.6 Reverse flow (Bi-directional flow) 7 3.0 ELECTRICL CONNECTIONS 8 3.1 Instrument cable 8 3.2 Pulse output selection (for pulse meters) 8 3.3 Pulse output boards 9 3.4 Output schematics 9 3.5 Hazardous area wiring 10 4.0 MINTENNCE 11 4.1 Dismantling 11 4.2 Inspecting 11 4.3 Re-assembling 11 5.0 CLENING IN-SITU 11 6.0 SPRE PRTS 12 6.1 Spare parts list 12 6.2 Spare parts diagram 13

2 1.0 OVERVIEW The Multipulse flow meter is a precision machined positive displacement flow meter incorporating the oscilating piston principal. These meters are capable of measuring most clean liquid flows irrespective of their chemical or physical properties. Multipulse flowmeters are available as blind pulse output meters or are available with integral or remote instruments including totalisers, flowrate displays or preset batch controllers. These instruments provide local display and are available with monitoring and control outputs including 4~20m, scaled pulse output, flow alarms and batch control outputs. If your flowmeter is fitted with or supplied with an instrument refer to the instrument instruction manual and I.S. supplement if fitted with an I.S. certified instrument. 316 stainless steel flow meters are suitable for a broad selection of water based products & chemicals, luminum meters are suitable for fuels & lubricants. flameproof option is available on all stainless steel and aluminum blind meters with pulse output. The Multipulse is also intrinsically safe when the reed switch pulse output is used in conjunction with an approved electrical safety barrier or when fitted with an intrinsically safe instrument. Typical I.S. barriers include: - MTL Model 5011 or 5012 - P & F Model KHD2-OT1-Ex1 1.1 Model number designation Size MP 015 1/2" ( 15mm ) 10~600 l/hr ( 0.04~2.7 USGM ) 025 1" ( 25mm ) 120~3000 l/hr ( 0.5~13.2 USGM ) 040 1 1/2" ( 40mm ) 250~8000 l/hr ( 1.1~35 USGM ) 050 2" ( 50mm ) 700~20000 l/hr ( 3~88 USGM ) Body material S 316L Stainless Steel luminium H High Pressure 316SS Piston material 2 PEEK ( polyetheretherkeytone - 150ºC [300ºF] max.) 3 CFT ( carbon filled teflon - 120ºC [212ºF] max.) Partition material 1 Ceramic - for abrasive or low lubricity liquids 2 316L Stainless Steel O-ring material 1 Viton ( standard - 150ºC [300ºF] max.) 2 EPR - ( Ethylene Propylene Rubber - 150ºC [300ºF] max.) 3 Teflon encapsulated viton ( 150ºC [300ºF] max.) 4 Buna-N ( Nitrile - 120ºC [212ºF] max.) Temperature limits - 2 120ºC (212ºF) max. - no integral cooling fin - 3 150ºC (300ºF) max. - Peek piston & Hall Effect output only - 5 120ºC (212ºF) max. - includes integral cooling fin Process connections 1 BSP-RP female threaded 2 NPT female threaded 3 Tri-clamp ferrules ( ferrules are 1/2" larger than meter size ) 4 NSI-150 RF flanges 5 NSI-300 RF flanges 6 PN16 DIN flanges 7 PN40 DIN flanges X Customer nominated ( covered under SB option ) Cable entries 0 3~6mm cable gland (exclusive to BT option) 1 M20 x 1.5mm 2 1/2" NPT Integral options GRN terminal cover (note 1) L luminum terminal cover SS Stainless terminal cover QP Quadrature pulse output E* Explosion proof ~ Exd Q* Exd with Quadrature pulse B2 BT11 dual totaliser B3 Intrinsically safe BT11 (I.S.) R2 RT12 Flow Rate Totaliser R3 Intrinsically safe RT12 (I.S.) E0 EB10 batch controller M o d e l N o. E x a m p l e SB Specific build requirement 3 MP 015 S 2 2 1-5 1 1 R2 Special Build No. : SB Quote special build & serial No's when ordering spares Note : 1) Standard meters are supplied with a GRN terminal cover ( glass re-inforced nylon ).

4 5 Specifications Model prefix MP015 MP025 MP040 MP050 Nominal size ( inches ) 15mm ( ½" ) 25mm ( 1" ) 40mm ( 1½" ) 50mm ( 2" ) Flow range ( litres / min ) 0.2 ~ 10 2 ~ 50 4 ~ 140 12 ~ 330 Flow range ( US gal / min ) 0.05 ~ 2.7 0.5 ~ 13 1.1 ~ 37 3.2 ~ 90 * Maximum flow ( fuels ) 12 L / min 80 L / min 160 L / min 350 L / min ( 3.2 gpm ) ( 21 gpm ) ( 42 gpm ) ( 92 gpm ) ccuracy @ 3cp ±1% o.r. ** ± 0.5% of reading Improved accuracy Repeatability Temperature range ± 0.2% of rate with optional RT12 using NLC typically ± 0.03% -40ºC ~ +200ºC ( -40ºF ~ +390ºF ) Maximum pressure ( threaded meters ) bar ( PSI ) aluminium 30 ( 440 ) 80 ( 1200 ) 30 ( 440 ) 20 ( 300 ) 316L stainless 100 ( 1500 ) 100 ( 1500 ) 100 ( 1500 ) 38 ( 560 ) high pressure stainless 350 ( 5150 ) 200 ( 2950 ) 250 ( 3700 ) Materials Body materials Terminal cover materials Piston materials Ertalyte PPS, PEEK or carbon filled teflon (CFT) O-ring materials viton, nitrile, EPR or teflon encapsulated viton Electrical - for pulse meters (see also optional outputs) Output pulse resolution ( nominal ) : pulses / litre ( pulses / US gallon ) N/ aluminum or 316 stainless steel ( PVDF also available ) GRN (std.), optional stainless steel or aluminum Reed switch 200 ( 760 ) 20 ( 76 ) 7.3 ( 28 ) 2.5 ( 9.5 ) Hall effect 400 ( 1520 ) 100 ( 380 ) 44 ( 167 ) 20 ( 76 ) # Reed switch output Hall effect output Electrical entry 30Vdc x 200m max. 3 wire open collector, 5~24Vdc max., 20m max. M20 x 1.5mm pitch or ½" NPT female threaded Physical Process connections Protection class Dimensions Pressure drop chart Chemical resistance chart BSPP or NPT, NSI or DIN flanges, hygienic IP66/67 (NEM4X) optional Exd IIB T6 or I.S. refer <www.trimecind.com> refer <www.trimecind.com> refer <www.trimecind.com> Recommended filtering 150 micron 250 micron 500 micron (minimum) ( 100 mesh ) ( 50 mesh ) ( 25 mesh ) 1.3 OPERTING PRINCIPLE The Multipulse flow meter utilises the oscillating piston principle, where the passage of liquid causes a piston to oscillate smoothly in a circular motion inside a round measuring chamber. Each piston cycle displaces a known volume of liquid from the inlet port to the outlet port. Small high energy magnets located within the piston activate the integral electronics which in turn generate high resolution pulse outputs suitable for remote flow integration instruments, computers and PLC's. 1) The liquid flows through inlet into the inner area of the piston causing the piston to move in the direction arrowed. B B Piston 2) The volume outside the piston, to the right, is displaced & exits through opening B. Liquid also flows through inlet into the left-hand outer area. B B * Maximum flow on fuels may be maintained for intermittent periods of refuelling. * Maximum flow is to be reduced as viscosity increases, max. pressure drop 280Kpa. (40psi) ** Within nominal spans of MP015 ( 0.17~1.7, 1.7~5 & 5~10 litres/min ) # Maximum thermal shock 10ºC (50ºF) / min. applies to the reed switch Flowmeter label The label plate identifies the flowmeter model number, serial number, temperature & pressure ratings. Temperature & pressure ratings are maximum and must not be exceeded. 3) The inner area of the piston is completely cut off. The liquid flowing through into the outer area moves the piston forward. 4) the volume of liquid within the piston flows through outlet B.

6 2.0 INSTLLTION 2.1 Orientation The flow meter can be mounted in any orientation. However, for optimum performance and ease of inspection, it is desirable to mount the flow meter in a horizontal section of pipe. This also ensures the rotating piston is not influenced by gravity when at rest. 2.2 Meter location The flow meter should be fitted upstream of any flow control or cut-off valve. This prevents free discharge from the flow meter and minimises the risk of drainage and air entrapment which will cause erroneous readings on start up. The Multipulse positive displacement flow meter does not require any flow conditioning, therefore straight runs of pipe before and after the flow meter are not necessary. The flow meter is not to be exposed to any form of hydraulic shock nor at any time over speeding as this could damage the internals. 2.3 By-pass Installation It is our recommendation the flow meter be installed in a by-pass section of pipe with isolation valves to enable the flow meter to be isolated during pipeline purging. If a by-pass is impractical, flush the pipe work to purge out foreign matter such as rust, welding slag and sealing compound prior to installing the flow meter or temporarily remove the piston, partition and centre bearing (if fitted) to allow free passage of the foreign matter. 2.5 Commissioning Immediately after installation or after long periods of shut down, the flow meter must be slowly purged of air. This can be achieved by allowing the liquid to flow through the flow meter at a slowly increasing rate until the air is released. When metering liquids with a viscosity greater than that of water, the maximum flow rate may need to be reduced to a level that will produce a pressure drop across the flow meter no greater than 280 kpa ( 2.8 bar ). The flow meter is now ready to be wired for service after which it will accurately measure all liquids passing through it, provided it is not operated outside its specified limits. 2.6 Reverse flow (bi-directional flow) The flow meter is capable of accurately measuring flow in the reverse direction. Where reverse flow is not to be registered it is wise to install a check valve upstream of the flow meter. Meters fitted with the QP output option (quadrature pulse output) may be interfaced with the Pulse Discriminator Module (PD1) to separate forward & reverse flow output pulses for input to the appropriate totalising registers or add and subtract counter input. It is important to note that the Quadrature Pulse outputs are NPN open collectors from the hall sensor however the outputs have the same pulse resolution (pulses/unit volume) as that of the reed switch for each size Multipulse flowmeter. 7 The by-pass configuration should also be used if the system is exposed to periodic steam or air purging. ( See 5.0 Cleaning In-Situ ) 2.4 Strainers It is recommended to locate a suitably sized strainer immediately upstream of the flow meter. Required strainer mesh sizes are. Model No. Mesh size Microns MP015 100 150 MP025 & MP040 50 250 MP050 25 500 range of strainers are available to suit both the Multipulse PD and Turbopulse turbine meter range. Flowmeter with QP outputs Reg Reg X X 5~24Vdc maximum supply Output Signal 1 (forward flow) Output Signal 2 (reverse flow) Ground Vdc + + 10 9 7 6 PD1 Pulse Discriminator +Vdc Sig.1 Sig.2 +8~24Vdc Forward flow Sig. Output signals Reverse flow Sig. 5 4 2 1

8 3.0 ELECTRICL CONNECTIONS 3.1 Instrument cable Twisted pair low capacitance shielded instrument cable 7 x 0.3mm (0.5mm²) should be used for electrical connection between the flow meter and remote instrumentation. The screen should be earthed at the readout instrument only to protect the transmitted signal from mutual inductive interference. The cable should not be run in a common conduit or parallel with power and high inductive load carrying cables as power surges may induce erroneous noise transients onto the transmitted pulse signal or cause damage to the electronics. Run the cable in a separate conduit or with low energy instrument cables only. 3.2 Pulse output selection ( for pulse meters ) Each flow meter has two independent pulse output signals that are linearly proportional to volumetric flow. Pulse transmission can be up to 1000 metres providing that wiring runs are in accordance with good wiring practices (see 3.1). Reed switch : voltage free contact closure output providing a regular frequency ideally suited for frequency to analog conversion & instantaneous flow rate indication. The Reed Switch can also be used for integrating and batching applications & can be connected into an approved intrinsically safe barrier when used in hazardous locations. Reed temperature gradient should not exceed 10ºC (50ºF) / minute. Maximum load is 24Vdc~100m &, a 0.25w x 500Ω current limiting resistor may be placed in series to protect the reed against higher potential spikes or loads. Hall Effect sensor : high resolution, solid state, 3 wire NPN open collector requiring 5~24 Vdc max. (20m max.), produces a pre-shaped and amplified square wave more suited to small volume batching applications requiring high levels of repeatability. The square wave pulses are unevenly spaced due to the cyclic motion of the piston but like the reed switch each pulse is representative of an equal volume. Pulse output resolution : Each flow meter is individually calibrated and supplied with a calibration certificate showing the number of pulses per unit volume for the Hall sensor and the reed switch output. Nominal figures are shown below. Model No. Hall Sensor Reed Switch Quadrature hall ( pulses / USgal ) ( pulses / USgal ) ( pulses / USgal ) MP015 400 PPL (1520) 200 PPL ( 760 ) 200 PPL ( 760 ) MP025 100 PPL ( 380 ) 20 PPL ( 76 ) 20 PPL ( 76 ) MP040 44 PPL ( 167 ) 7.3 PPL ( 28 ) 7.3 PPL ( 28 ) MP050 20 PPL ( 76 ) 2.5 PPL ( 9.5 ) 2.5 PPL ( 9.5 ) 3.3 Pulse output boards REED SW1 MP015 MP050 + VDC -OV SIG -OV VDC + SIG REED SW 3.4 Output schematics REED SWITCH REG 8 7 6 Solder pads Reed = 2 & 3 Hall = 1,2 & 3 OUTPUT output selector NPN PNP + output + input 8~30Vdc supply 500Ω MP025 -OV + VDC SIG REED SW Ground X Output Signal 5~24 Vdc MX. voltage HLL EFFECT (NPN open collector) Optional PR1 pulse repeater / isolator +24Vdc out Reed Sw Reed Sw + Vdc 3 2 1 + -OV SIG MP040 VDC REED SW Note on REED SWITCH : The reed switch is sensitive to thermal shock & may fail if subjected to temperature gradients greater than 10ºC (50ºF) / minute. Bridge solder pads when the 500Ω current limiting resistor is not required, (only applies to meters fitted with the resistor). Important: Hall effect supply voltage is to be limited to 24Vdc maximum, should it be possible for the voltage to spike beyond 24Vdc install the PR1 pulse repeater / isolator module as shown below. 9

10 3.5 Hazardous area wiring If the flow meter has been supplied with the "explosion proof option" Exd IIB T4/T6, then the following points must be observed: 1) Wiring techniques must be in accordance with the rules, regulations & requirements applying to the territory in which the meter is installed. The units should only be connected and set up by qualified staff. The qualified staff must have knowledge of protection classes, regulations and provisions for the apparatus in hazardous areas. 2) When using shielded cable do not use the shield as an electrical earthing conductor. Be sure to isolate the shield / screen from any contact with the flow meter. The shield / screen is to be connected to the instrument earth only to protect the transmitted signal from mutual inductive interference. Electrical earthing lugs are located within the terminal housing cover & on the underside of the manifold. Use a separate earth within the cable making sure that the earth conductor does not come in electrical contact with the cable shield / screen. 3) Use only high temperature cable at the flow meter if the unit is being used to measure process liquids above 85 C. 4) For Exd explosion proof versions only, the output board has been assembled into the flow meter terminal housing using a small amount of potting solution. If the output board is to be replaced in an Exd version, remove the two PCB screws and then the output board (force will be needed to break the PC board away from the potting solution). Clear away all remaining potting solution. To fit the new output board first fill the recesses in the bottom of the terminal housing with a small amount of potting solution ( approximately 2ml ) so that there is about 2mm depth of coverage within the recess slots then fit new output board and allow time for potting solution to set. Use 3M Scotch guard 2130 potting solution or similar. I.S. wiring using the reed switch as a simple apparatus must be in accordance with the rules, regulations & requirements applying to the territory in which the flowmeter is being installed. If the flowmeter is fitted with an intrinsically safe instrument refer to the appropriate instrument instruction manual & I.S. supplement for wiring of power connections & outputs. 4.0 MINTENNCE 4.1 Dismantling The Multipulse has been constructed in such a way that the flow meter manifold need not be disturbed when servicing the flow meter in-situ. Isolate the flow meter from its source of supply and allow any excess liquid to drain out. Remove the cap screws located around the flow meter body and gently lever the body off the manifold at the slots provided on either side. Caution: Lever action needs to be even on both sides so as to avoid 'walking' the body from side to side. This inturn could damage the ceramic partition or piston spigot, for this reason ceramic partitions are not covered by warranty. 4.2 Inspecting Lift the piston out of the flow meter and inspect for signs of wear or damage. Ensure that no particles are impinged into the piston walls and remove any foreign material inside the flow meter. Inspect the O-ring and centre bearing for damage or wear. Replace any suspect parts (refer 6.0 Spare Parts). 4.3 Re-assembling Replace the bearing (when fitted) & piston and rotate it by hand to ensure freedom of movement. lign the slot in the body with the partition plate and firmly press the body evenly onto the manifold. smear of lubricant on the O-Ring will assist. CUTION, the partition plate is rectangular on all models & must be assembled with the long face to the centre boss of the manifold. 5.0 CLENING IN-SITU When a system is to be cleaned in place (CIP), sterilised or purged without removal of the flow meter, it is advisable to provide a by-pass around the flow meter to avoid damaging the piston unless the following recommendations are adhered to. 1) The cleaning fluid must be compatible with the piston and O-ring materials. 2) During steam sterilising ensure the steam temperature does not exceed the maximum operating temperature of the flow meter. 3) The velocity of the steam (also applies to air or gas ) must be carefully restricted to ensure the velocity of the piston never exceed the equivalent of maximum flow rate of he meter. The purge period must not exceed 30 seconds as the meter piston is without lubrication during the purge cycle. 11

13 12 6.2 Spare parts diagram 6.0 SPRE PRTS ( see notes ) Item Description MP015 MP025 MP040 MP050 1 Piston Part No. Part No. Part No. Part No. Ertalyte 60ºC 1424104 1424105 1424106 1424107 Ertalyte 120ºC 1424094 1424095 1424096 1424097 R PEEK 60ºC 1424011 1424016 1424021 1424026 E PEEK 120ºC 1424012 1424017 1424022 1424027 C PEEK 150ºC 1424013 1424018 1424023 1424028 O CFT 60ºC 1424014 1424019 1424024 1424029 M CFT 120ºC 1424015 1424020 1424025 1424030 M 2 Partition E ceramic 1310001 1310003 1310005 1310007 N stainless steel 1310002 1310004 1310006 1310008 D 3 Manifold bearing E PEEK BG - 1321003 1321005 1321007 D CFT - 1321004 1321006 1321008 4 Manifold O-ring (size BS130) (size BS148) (size BS241) (size BS250) S viton 13031301 13031481 13032411 13032501 P EPR 13031302 13031482 13032412 13032502 teflon encapsulated viton 13031303 13031483 13032413 13032503 R buna-n 13031304 13031484 13032414 13032504 E 5 Pulse output board S aluminum & stainless meters 1412001 1412003 1412004 1412019 Quadrature pulse meters ( QP ) - 1412047-1412044 PCB potting solution ( Exd models ) 1325001 1325001 1325001 1325001 6 Output board screw M3 x 4mm cheese head 130803101 130803101 130803101 130803101 7 Terminal cover GRN glass re-inforced (M20) 1306012 1306012 1306012 1306012 GRN glass re-inforced (1/2" NPT) 1306018 1306018 1306018 1306018 aluminum (M20) 1306003 1306003 1306003 1306003 aluminum (1/2" NPT) 1306006 1306006 1306006 1306006 stainless steel (M20) 1306001 1306001 1306001 1306001 stainless steel (1/2" NPT) 1306008 1306008 1306008 1306008 8 Terminal cover screw M5 x 12mm socket head 130805105 130805105 130805105 130805105 9 Terminal cover O-ring for metal covers (BS132) 13031321 13031321 13031321 13031321 for GRN covers (BS032) 13030321 13030321 13030321 13030321 10 Body stainless steel 1402029 1402032 1402016 1402022 aluminum 1402030 1402033 1402017 1402023 11 Body screw stainless steel screws 130806101 130806101 130808101 130808102 high tensile (high pressure meters) 130806118 130806123 - - 12 Manifold ( refer factory for flanged or other non-threaded manifolds ) stainless ( BSP-RP ) 1401062 1401005 1401009 1401013 stainless ( NPT ) 1401063 1401006 1401010 1401014 aluminum ( BSP-RP ) 1401069 1401007 1401011 1401015 aluminum ( NPT ) 1401070 1401008 1401012 1401016 5 11 2 4 RIMEC BR CL 3 8 7 9 6 10 1 Item 3 not included on models MP015 supplied after May 04 New style O-ring configuration from year 2000 on 12 note : Meters with model number ending in "SB" (specific build) & serial number ending in "X" may require special parts, advise factory of serial number when ordering parts for these meters. Meters with model No.s ending in QP require special parts, contact factory for details. CL