Balancing Valves. Venturi Commissioning Valve (FODRV) & (DRV) Cu x Cu Compression DN10-DN50. BOSS TM 901SC Venturi DRV DN

Similar documents
950x. Description. Part List

9574P Cast Iron Variable Orifice Static Balancing Valve

Description. Ballorex Venturi. Versions. Benefits. Robinets manuels Balancing

Ballorex Venturi 3.1 Introduction

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

VE-S_15-32 Pressure Independent Balancing & Control Valves

Ballorex commissioning valves

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40

Pressure Independent Control Valve

Innovation + Quality. Valves, controls + systems Balancing and Control Valves

Direct/Factory Mounting Valve Set

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Pressure Independent Control Valve

Section 20. HVAC Valves & Products

TA-Mini-Fast-Fit. Prefab units Fabricated solutions for small terminal units

2-position electric actuators with Ball valves VBZ ½...11/4

4017 M HERZ Dimensions in mm

Innovation + Quality. Valves, controls + systems Balancing and Control Valves

FCU 6-PORT PICV VALVE SET MODULE BROCHURE

Terminator PICV. Technical Manual

ROTARY PRESSURE INDEPENDENT CONTROL VALVE TECHNICAL MANUAL

STAF-SG. ANSI flanges. Balancing valves DN

CIMBERIO VALVES. SAV Systems. Product Brochure.

Technote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.

R2F Compact Commissioning & 4 Port Control Valve Fan Coil Unit Valve Set Module

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

Manual Presetting Valves LENO MSV-B

SKU: DR4306. Fixed Orifice Double Regulating Valve

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

Manual presetting valves LENO MSV-BD

TA-6-way valve. Standard control valves 6-way valve for change-over systems

Components for central heating

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

Product Catalogue November 2017

Circuit Regulating Valve STRÖMAX GF

Valves, controls + systems Cast iron double regulating/ commissioning valves PN 16 Hydrocontrol G

STAF-SG. ANSI flanges. Balancing valves Size 3/4-16

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS

PCS. HVAC Products. Technical submission. Type of Product

502 brass ball valve with ADA pneumatic actuator

HERZ-Connect 4 / Compact Connect 4 & Commissioning Centres

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

CBV Series. Circuit Balancing Valves

Ballorex Vario. Description. Versions. Benefits. Applications. Balancing

Valid from

Butterfly valve with ADA pneumatic actuator

3-port seat valves, external thread, PN16

HERZ-Motorised flow controler

Automatic balancing valves ASV-PV DN (3rd gen.)

CONTENTS. Double Flow Measurement Device 1. Fixed Orifice Double Regulating Valve 3. Variable Orifice Double Regulating Valve 7

TOTAL PRODUCT O U R G E N I U S I S V A L V E S & P I P E F I T T I N G S W A T E R H E A T I N G V E N T I L A T I O N A I R C O N G A S

Valves for building. Y-strainers... page 204 PVC valves Ball valves... page 204 Butterfly valve... page 204 Ball check valve...

VALVES WITH UM ELECTRIC ACTUATOR

3-Port Seat Valves with Male Thread, PN 16

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

9500 VIR VALVOINDUSTRIA ING.RIZZIO SPA

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

3-port seat valves PN16 with flanged connection

9907T Straight DZR Brass Automatic Balancing Valve

PNEUMATICALLY ACTUATED 2-WAY

Valves for building. Y-strainers... page 272 PVC valves Ball valves... page 272 Butterfly valves... page 272 Ball check valves...

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

Valves, controllers + systems Double regulating and commissioning valves Hydrocontrol F cast iron, PN 16

VALVES WITH UV ELECTRIC ACTUATOR

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

715 XS BALL VALVE + ADA PNEUMATIC ACTUATOR

DESCRIPTION 9.4 G 3/4"M

2-port and 3-port ball valves PN 40

Serie Ekoflux S. Flanged balancing valve. Application fields. Regulation. Ekoflux.S_GB_22/04/2015 HEATING CONDITIONING

Cast-Iron Valves G101 DI BUTTERFLY VALVE LEVER... 2 G401 CI GLOBE VALVE CL G403 CI GLOBE VALVE PN G103 DI BUTTERFLY VALVE GEAR...

2-port ball valves with flanged connection, PN25

Butterfly valves PN6, PN10, PN16

Pressure Independent Control Valve AB QM, ½ thru 2 2½ thru 4 5 thru 10 Valve Size

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Valves. Valves Range 1340 Double Check Valves PN16. Material Specification

Cast Iron Valves. Product Information. It s all at Albion

Butterfly valve with ADA pneumatic actuator

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Combi valves, PN 25. for rooms, zones, ventilation and air-conditioning systems

771 XS BALL VALVE WITH ADA PNEUMATIC ACTUATOR

ZONE CONTROLE / 2-WAY

485 - NC NO/DA DN

Harmony Installation, Operation and Maintenance

BROEN BALLOREX Dynamic R E ADY STEADY GO!

VALVES WITH SA ELECTRIC ACTUATOR

502 VALVE WITH UM1.5 ELECTRIC ACTUATOR. Model/Ref:

Control valves with electric actuators up to 90 C PN

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

ABV 4-PORT VALVE SET MODULE

Pressure Independent Control Valve

Electric Actuated Butterfly Valves Ductile Iron Wafer Body ASME 150# 2 to 6 Pipe

Double regulating and commissionig valves Hydrocontrol F cast iron, PN 16 Hydrocontrol FR bronze, PN 16 Hydrocontrol FS nodular cast iron, PN 25

PL1 VALVE WITH UM ELECTRIC ACTUATOR

TECHNICAL SPECIFICATIONS 63/2E DN15 Kvmax /4"E. ( 3 4"x18) 3/4"E

Motorized Butterfly Valve

Transcription:

Venturi Commissioning Valve (FODRV) & (DRV) Cu x Cu Compression DN-DN Balancing Valves BOSS TM 900SC Venturi FODRV DN1- BOSS TM 901SC Venturi DRV DN1- Specification The commissioning station and DRV incorporates a characterised regulating needle combined with an isolating ball valve. The double regulating feature allows the valve to be isolated without movement of the set regulation point. The needle is regulated using an allen key. The valve is suitable for mounting in any orientation. The flow rate is measured using a fixed orifice Venturi cartridge with double seal test points inserted into the valve body. These functions are incorporated into a single fitting which contains any up and down stream lengths required for laminar flow conditions except when installed in close proximity to a pump. The commissioning valve should produce a signal of between except on the ultra low flow valves where the signal should be between 1 4.7. The valve is suitable for mounting with the test points pointing down. The commissioning station has an accuracy of +/-%. 4.1

Balancing Valves Technical Specification Cu x Cu Compression FODRV DRV Pressure & Temperature Classification Temperature Max (Max) 1ºC 1ºC Pressure (Max) Materials of Construction Valve body Spindle Ball & adjusting screw Gaskets O-rings (seals) Handle Measuring P/T plug Rubber in P/T plug DZR Brass CW2N CuZn6Pb2As DZR Brass CW2N CuZn6Pb2As DZR Brass CW2N CuZn6Pb2As Chromium Plated PTFE EPDM Polyamide P6.6 % Glass Reinforced DZR Brass CW2N CuZn6Pb2As EPDM Markings on Valves Valve Body (Compression & Female) DN & PN DN & PN Valve Body (Pressfit) DN & PN2 DN & PN2 Handle DN & Kvs Value DN Connection Compression Pressure Test According to EN124-2 ISO8:199E Range Cu x Cu Compression Connections FODRV DRV Valve Size Kvs Rates* Signal Head Loss Loss Valve Kvs Kvs Factor Size DN Description m h m h DN m h 1 Ultra Low 6 0.0076 to 1.2 to 9.8 26 2 Low 9 0.0172 to 0.074 1 to 29 1L 1.62 Standard 0.746 6 to 48 9 to 1 1.62 1 1S 2.11 High 1.6 0.074 to 2 to 6 2.49 9 Low 0.746 6 to 48 9 to 1 1.4 7 L 4.26 Standard 1.6 0.074 to 2 to 6 2.82 1 S 4.81 High 2.9 42 to to 4.72 7 2 Standard 2.9 42 to to 4 7.4 2S 9.94 High 6.01 9 to 1.2 to 6 12. 2 High 6.01 9 to 1.2 to 6 1. 1 2S 1. High 9.2 4 to 1.88 to 4 22.00 7 S 2. High 17.1 0.82 to.1 to 6.00 S. * The flow rates given in the table are for water flow in steel pipes which provide a pressure loss of to 0 Pa per metre of pipe. 4.2

A B C BOSS TM 900SC D Balancing Valves Weights & Dimensions FODRV Cu x Cu Compression Size Nominal A B C D Weight Product DN Size mm mm mm mm kg Code 1L 1mm 99 7 164 76 41 2729 1S 1mm 99 7 164 76 41 27 1H 1mm 99 7 164 76 41 2744 L 22mm 7 170 79 0.717 2769 S 22mm 7 170 79 0.717 2714 H 22mm 7 170 79 0.717 2744 2S 28mm 118 7 177 7 0.998 272 2H 28mm 118 7 177 8 0.998 2746 2H mm 1 122 241 9 1.806 276 H 42mm 149 122 2 11 2.8 2747 H 4mm 167 122 26 1.818 278 BOSS TM 901SC Weights & Dimensions DRV Cu x Cu Compression Size Nominal A B C D Weight Product DN Size mm mm mm mm kg Code 1L 1mm 62 7 128 76 66 274168 1S 1mm 62 7 128 76 66 2749 L 22mm 67 7 12 79 12 274190 S 22mm 67 7 12 79 12 2742 2S 28mm 81 7 1 8 0.798 27421 2S mm 9 122 199 9 1.46 274242 S 42mm 7 122 211 11 2.118 2742 S 4mm 126 122 224 1.248 274264 Measurement measurements are via the Venturi nozzle. The BOSS TM Venturi has two test points (P/T plugs). The high pressure test point is identified by the RED retaining clip and the low pressure test point is identified by the BLUE retaining clip. The pressure differential measured between these test points can be used to calculate the actual flow through the Venturi. This differential can be measured using a flow meter or other measuring device. This is converted into a flow rate of litres per second () or metres cubed per hour (m /h) either electronically or using a calculation formula. Valve Sizing Sizing disc available on request via your local BSS branch or BSS technical on 0116 26 702. Digital Manometer See Page 4.14 4.

Balancing Valves Venturi Commissioning Station (FODRV) & (DRV) Female x Female DN-DN BOSS TM 900S Venturi FODRV DN1- BOSS TM 901S Venturi DRV DN1- Specification The commissioning station and DRV incorporates a characterised regulating needle combined with an isolating ball valve. The double regulating feature allows the valve to be isolated without movement of the set regulation point. The needle is regulated using an allen key. The valve is suitable for mounting in any orientation. The flow rate is measured using a fixed orifice Venturi cartridge with double seal test points inserted into the valve body. These functions are incorporated into a single fitting which contains any up and down stream lengths required for laminar flow conditions except when installed in close proximity to a pump. The commissioning valve should produce a signal of between except on the ultra low flow valves where the signal should be between 1 4.7. The valve is suitable for mounting with the test points pointing down. The commissioning station has an accuracy of +/-%. 4.4

Balancing Valves Technical Specification Female x Female FODRV DRV Pressure & Temperature Classification Temperature Max (Max) 1ºC 1ºC Pressure (Max) 2 2 Materials of Construction Valve body Spindle Ball & adjusting screw Gaskets O-rings (seals) Handle Measuring P/T plug Rubber in P/T plug DZR Brass CW2N CuZn6Pb2As DZR Brass CW2N CuZn6Pb2As DZR Brass CW2N CuZn6Pb2As Chromium Plated PTFE EPDM Polyamide P6.6 % Glass Reinforced DZR Brass CW2N CuZn6Pb2As EPDM Markings on Valves Valve Body (Compression & Female) DN & PN DN & PN Valve Body (Pressfit) DN & PN2 DN & PN2 Handle DN & Kvs Value DN Connection Female thread Pressure Test According to ISO 7/1 Parallel ISO8:199E Range Female x Female Connections FODRV DRV Valve Size Kvs Rates* Signal HeadLoss Loss Valve Kvs Kvs Factor Size DN Description m h m h DN m h 1 Ultra Low 6 0.0072-0.00 1.2-9.8 26 2 Low 9 0.01-0.074 1-29 1L 1.62 Standard flow 0.746 0.062-48 9-1 1.62 1 1S 2.11 High 1.6 8-2 - 6 2.49 9 Low 0.746 0.062-48 9-1 1.4 7 L 4.26 Standard flow 1.6 8-2 - 6 2.82 1 S 4.81 High 2.9 8 - - 4.72 7 2 Standard flow 2.9 8 - - 4 7.4 2S 9.94 High 6.01 4-1.2-6 12. 2 High flow 6.01 4-1.2-6 1. 1 2S 1. High flow 9.2 0.81-1.88-4 22.00 7 S 2. High flow 17.1 1.2 -.1-6.00 S. * The flow rates given in the table are for water flow in steel pipes which provide a pressure loss of to 0 Pa per metre of pipe. 4.

A B C BOSS TM PS900S A B C D D Weights & Dimensions FODRV Female x Female Size Nominal A B C D Weight Product DN Size mm mm mm mm kg Code 1UL 1 2in 94 7 144 76 27188 1L 1 2in 94 7 1 76 27199 1S 1 2in 94 7 1 76 9 277 1H 1 2in 94 7 1 76 9 274 L 4in 7 144 79 2727 S 4in 7 144 79 9 27218 H 4in 7 144 79 9 27421 2S 1in 112 7 1 8 7 27229 2H 1in 112 7 1 8 7 2742 2H 1 1 4in 1 122 8 9 1.27 272 H 1 1 2in 1 122 21 11 1.66 2721 H 2in 16 122 221 1 2.7 27262 Weights & Dimensions DRV Female x Female Size Nominal A B C D Weight Product DN Size mm mm mm mm kg Code 1L 1 2in 7 7 4 76 27967 1S 1 2in 7 7 4 76 2706 L 4in 62 7 6 79 9 27989 S 4in 62 7 6 79 9 2717 2S 1in 7 7 11 8 7 2728 2S 1 1 4in 88 122 166 9 1 279 S 1 1 2in 122 171 11 11 1.24 27 S 2in 11 122 180 1 1.80 2761 BOSS TM 901S Measurement measurements are via the Venturi nozzle. The BOSS TM Venturi has two test points (P/T plugs). The high pressure test point is identified by the RED retaining clip and the low pressure test point is identified by the BLUE retaining clip. The pressure differential measured between these test points can be used to calculate the actual flow through the Venturi. This differential can be measured using a flow meter or other measuring device. This is converted into a flow rate of litres per second () or metres cubed per hour (m /h) either electronically or using a calculation formula. Valve Sizing Sizing disc available on request via your local BSS branch or BSS technical on 0116 26 702. Digital Manometer See Page 4.14 4.6

Balancing Valves Venturi Commissioning Station (FODRV) & (DRV) Pressfit Connections DN1-DN BOSS TM PS900S Venturi FODRV DN1- BOSS TM PS901S Venturi DRV DN1- Specification The commissioning station and DRV incorporates a characterised regulating needle combined with an isolating ball valve. The double regulating feature allows the valve to be isolated without movement of the set regulation point. The needle is regulated using an allen key. The valve is suitable for mounting in any orientation. The flow rate is measured using a fixed orifice Venturi cartridge with double seal test points inserted into the valve body. These functions are incorporated into a single fitting which contains any up and down stream lengths required for laminar flow conditions except when installed in close proximity to a pump. The commissioning valve should produce a signal of between except on the ultra low flow valves where the signal should be between 1 4.7. The valve is suitable for mounting with the test points pointing down. The commissioning station has an accuracy of +/-%. 4.7

Technical Specification Pressfit Connections FODRV DRV Pressure & Temperature Classification Temperature Max (Max) 1ºC 1ºC Pressure Female (Max) 16 16 Materials of Construction Valve body Spindle Ball & adjusting screw Gaskets O-rings (seals) Handle Measuring P/T plug Rubber in P/T plug DZR Brass CW2N CuZn6Pb2As DZR Brass CW2N CuZn6Pb2As DZR Brass CW2N CuZn6Pb2As Chromium Plated PTFE EPDM Polyamide P6.6 % Glass Reinforced DZR Brass CW2N CuZn6Pb2As EPDM Markings on Valves Valve Body (Compression & Female) DN & PN DN & PN Valve Body (Pressfit) DN & PN2 DN & PN2 Handle DN & Kvs Value DN Connection Pressfit (bronze) Pressure Test According to BS87: ISO8:199E 4.8

Range Pressfit Connections FODRV DRV Valve Size Kvs Rates* Signal HeadLoss Loss Valve Kvs Kvs Factor Size DN Description m h m h DN m h 1 Ultra Low 6 0.0072 -.0-9.8 26 2 Low 9 0.01-0.074.0-29 1L 1.62 Standard flow 0.746 0.062-48.0-1 1.62 1 1S 2.11 High 1.6 8-2.0-6. 2.49 9 1/18 Ultra Low 6 0.0072 -.0-9.8 29 2 Low 9 0.01-0.074.0-29 1/18L 1.62 Standard 0.746 0.062-48.0-1 1.6 1/18S 2. High 1.6 8-2.0-6. 2.49 9 Low 0.746 0.062-48.0-1 1.4 7 /1L 4.26 Standard flow 1.6 8-2.0-6. 2.82 1 /1S 4.79 High 2.9 8 -.0-4.72 7 /18 Low 0.746 0.062-48.0-1 1.4 7 /18L 4.26 Standard flow 1.6 8-2.0-6. 2.82 1 /18S 4.79 High 2.9 8 -.0-4.72 7 /22 Low 0.746 0.062-48.0-1 1.4 7 /22L 4.26 Standard flow 1.6 8-2.0-6. 2.82 1 /22S 4.81 High 2.9 8 -.0-4.72 7 2/28 Standard flow 2.9 8 -.0-4 7.4 2/28S 12.80 High 6.01 4-1.2.0-6 12. 2/ High flow 6.01 4-1.2.0-6 1. 1 2/S 1.28 /42 High flow 9.2 0.81-1.88.0-4 22.00 7 /42S 2. /4 High flow 17.1 1.2 -.1.0-6.00 /4S. * The flow rates given in the table are for water flow in steel pipes which provide a pressure loss of to 0 Pa per metre of pipe. Measurement measurements are via the Venturi nozzle. The BOSS TM Venturi has two test points (P/T plugs). The high pressure test point is identified by the RED retaining clip and the low pressure test point is identified by the BLUE retaining clip. The pressure differential measured between these test points can be used to calculate the actual flow through the Venturi. This differential can be measured using a flow meter or other measuring device. This is converted into a flow rate of litres per second () or metres cubed per hour (m /h) either electronically or using a calculation formula. Valve Sizing Sizing disc available on request via your local BSS branch or BSS technical on 0116 26 702. Digital Manometer See Page 4.14 4.9

BOSS TM PS900S Weights & Dimensions FODRV Pressfit Connections Size Nominal A B C D Weight Product DN Size mm mm mm mm kg Code 1/1UL 1 18 7 162 76 9 2771 1/1L 1 18 7 162 76 9 276 1/1S 1 18 7 162 76 9 2717 1/1H 1 18 7 162 76 9 2728 1/18UL 1 18 7 162 76 9 27742 1/18L 1 18 7 162 76 9 279 1/18S 1 18 7 162 76 9 27 1/18H 1 18 7 162 76 9 2761 /1L 14 7 166 79 1 2772 /1S 14 7 166 79 1 278 /1H 14 7 166 79 1 2794 /18L 14 7 166 79 1 272 /18S 14 7 166 79 1 2761 /18H 14 7 166 79 1 27624 /22L 147 7 166 79 2 276 /22S 147 7 166 79 2 27646 /22H 147 7 166 79 2 2767 2/28S 2 16 7 177 8 0.88 27668 2/28H 2 16 7 177 8 0.88 27679 2/H 2 188 122 27 9 1.62 27690 /42H 194 122 2 11 2.18 27709 /4H 2 122 26 1.8 277 BOSS TM PS901S Weights & Dimensions DRV Pressfit Connections Size Nominal A B C D Weight Product DN Size mm mm mm mm kg Code 1/1L 1 1 7 126 76 1 274 1/1S 1 1 7 126 76 1 27416 1/18L 1 1 7 126 76 1 27427 1/18S 1 1 7 126 76 2 2748 /1L 1 7 128 79 9 27449 /1S 1 7 128 79 9 274 /18L 1 7 128 79 9 27471 /18S 1 7 128 79 9 27482 /22L 9 7 128 79 2749 /22S 9 7 128 79 2741 2/28S 2 128 7 1 8 8 274412 2/H 2 146 122 19 9 1. 27442 /42H 172 122 198 11 1.77 27444 /4H 2 122 198 11 2.81 27444 4.

Venturi Commissioning Valve with Drain Balancing Valves BOSS TM 90 Venturi Specification The commissioning station and DRV incorporates a characterised regulating needle combined with an isolating ball valve. The double regulating feature allows the valve to be isolated without movement of the set regulation point. The needle is regulated using an allen key. The valve is suitable for mounting in any orientation. The flow rate is measured using a fixed orifice Venturi cartridge with double seal test points inserted into the valve body. These functions are incorporated into a single fitting which contains any up and down stream lengths required for laminar flow conditions except when installed in close proximity to a pump. The commissioning valve should produce a signal of between except on the ultra low flow valves where the signal should be between 1 4.7. The valve is suitable for mounting with the test points pointing down. The commissioning station has an accuracy of +/-%. Technical Specification Female x Female / Pressfit Connection Pressure & Temperature Classification Max Temperature 1ºC Min Temperature -ºC Max Pressure 2 (Pressfit to 16 ) Materials of Construction Valve Body Ball and Needle Valve Handle Sealings O-rings Gaskets Test Point Sealings Markings on Valve Valve Body KV Measuring Handle DZR Brass CW2N DZR Brass CW2N (chrome plated) Polyamide (PA6.6 %GF) EPDM PTFE Test Point Sealings EPDM DN, PN, Direction (KV-Measuring) DN, Version 4.11

Balancing Valves Range Female x Female / Pressfit Connections FODRV DRV Valve Size Kvs Rates* Signal HeadLoss Loss Valve Kvs Kvs Factor Size DN Description m h m h DN m h 1 Ultra Low 0.0076 -.0-9.8 26 2 Low 0.0172-0.074.0-29 1L 1.62 Standard flow 1.62 6-48.0-1 1.62 1 1S 2.11 High 2.49 0.074-2.0-6. 2.49 9 1/18 Ultra Low 0.0076 -.0-9.8 29 2 Low 0.0172-0.074.0-29 1/18L 1.62 Standard 1.62 6-48.0-1 1.6 1/18S 2. High 2.49 0.074-2.0-6. 2.49 9 Low 1.4 6-48.0-1 1.4 7 /1L 4.26 Standard flow 2.82 0.074-2.0-6. 2.82 1 /1S 4.79 High.72 42 -.0-4.72 7 /18 Low 1.4 6-48.0-1 1.4 7 /18L 4.26 Standard flow 2.82 0.074-2.0-6. 2.82 1 /18S 4.79 High.72 42 -.0-4.72 7 /22 Low 1.4 6-48.0-1 1.4 7 /22L 4.26 Standard flow 2.82 0.074-2.0-6. 2.82 1 /22S 4.81 High.72 42 -.0-4.72 7 2/28 Standard flow 7.4 42 -.0-4 7.4 2/28S 12.80 High 12.1 9-1.2.0-6 12. 2/ High flow 1.2 9-1.2.0-6 1. 1 2/S 1.28 /42 High flow 22.0 4-1.88.0-4 22.00 7 /42S 2. /4 High flow 6.0 0.82 -.1.0-6.00 /4S. * The flow rates given in the table are for water flow in steel pipes which provide a pressure loss of to 0 per metre of pipe. Weights & Dimensions Female x Female Size Nominal A B C D Weight Product DN Size mm mm mm mm kg Code 1UL 1mm 94 7 174 76 2748 1L 1mm 94 7 174 76 27419 1S 1mm 94 7 174 76 274 1H 1mm 94 7 174 76 27441 L mm 7 174 79 2742 S mm 7 174 79 2746 H mm 7 174 79 27474 2S 2mm 112 7 17 8 0.8 2748 2H 2mm 112 7 17 8 0.8 27496 2H 2mm 1 112 228 9 1. 2744 H mm 1 122 24 11 1.7 27461 H mm 16 122 28 1 2.4 274626 4.12

Weights & Dimensions Pressfit Connections Size Nominal A B C D Weight Product DN Size mm mm mm mm kg Code 1UL 1 x 1mm 14 7 174 76 27467 1L 1 x 1mm 14 7 174 76 274648 1S 1 x 1mm 14 7 174 76 27469 1H 1 x 1mm 14 7 174 76 274670 1UL 1 x 18mm 147 7 174 76 4 274681 1L 1 x 18mm 147 7 174 76 4 274692 1S 1 x 18mm 147 7 174 76 4 274700 1H 1 x 18mm 147 7 174 76 4 274711 L x 1mm 14 7 174 79 0.76 274722 S x 1mm 14 7 174 79 0.76 2747 H x 1mm 14 7 174 79 0.76 274744 L x 18mm 11 7 174 79 0.76 2747 S x 18mm 11 7 174 79 0.76 274766 H x 18mm 11 7 174 79 0.76 274777 L x 22mm 161 7 174 79 0.77 274788 S x 22mm 161 7 174 79 0.77 274799 H x 22mm 161 7 174 79 0.77 274807 2S 2 x 28mm 187 7 17 8 1 274818 2H 2 x 28mm 187 7 17 8 1 274829 2H 2 x mm 21 112 228 9 1.78 2748 H x 42mm 277 122 24 11 2.08 27481 H x 4mm 1 122 28 1.07 274862 Measurement measurements are via the Venturi nozzle. The BOSS TM Venturi has two test points (P/T plugs). The high pressure test point is identified by the RED retaining clip and the low pressure test point is identified by the BLUE retaining clip. The pressure differential measured between these test points can be used to calculate the actual flow through the Venturi. This differential can be measured using a flow meter or other measuring device. This is converted into a flow rate of litres per second () or metres cubed per hour (m/h) either electronically or using a calculation formula. Valve Sizing Sizing disc available on request via your local BSS branch or BSS Technical on 0116 26 702. 4.1

Manometer The Manometer (Balancing Computer BC2) is a compact handheld instrument for effective system commissioning. Smart menu for easy handling Valve images for fast identification Quick coupling pressure ports -value calculated and displayed directly Data logging function up to 000 records Up to 10 pre-programmed balancing valves Project commissioning with the possibility of printing balancing reports Anti-freeze media density correction Real time measurement recording Valve pre-setting calculation Technical Specification Product Code 274467 Pressure nominal range 0 Max. overpressure 1% of nominal range Linearity and hysteresis error % of nominal range Temperature error % of nominal range Media temperature - to 90ºC Operating temperature - to 90ºC Storage temperature - to 90ºC Power Internal 900 mah rechargeable Li-lon battery Power consumption 80 ma with active display Standby consumption µa Number of records 000 max. Number of valve producers Number of valves in the library 10 max. Charging/Communication Mini USB V/0 ma Display x 2 pixels, 6 K colours Keypad 9 keys Cover IP6 Calibration validity 12 months Mass 4 g 4.14

BOSS TM 900S, 900SC, 901S & 90 For calculation of flow rate formula see page 4. DN 1 diagrams DN 1UL - Ultra low flow 0.8 0.7 80 70 Pressure drop across valve Position 2.0.0 4.0.0 6.0 7.0 9.9 0.08 0.07 0.06 0.04 0.02 8 7 6 4 2 0.01 1 0.00 0.006 0.007 0.008 0.009 0.01 0.02 18.0 21.6 2.2 28.8 2.4 6.0 72.0 8.0 126.0 DN 1L - Low flow 0.8 0.7 80 70 Pressure drop across valve Position 2.0.0 4.0.0 6.0 9.9 7.0 0.08 0.07 0.06 0.04 0.02 8 7 6 4 2 0.01 1 0.01 0.02 0.04 0.06 0.074 6.0 72.0 8.0 144.0 180.0 216.0 266.4 4.1

BOSS TM 900S, 900SC, 901 & 90 DN 1 diagrams DN 1S - Standard flow 0.8 0.7 80 70 Pressure drop across valve Position 0.0 2.0.0 4.0 6.0 7.0 8.0 0.08 0.07 0.06 8 7 6 9.9 0.04 4 6 0.04 0.06 0.07 0.08 0.09 48 129.6 144.0 180.0 216.0 22.0 288.0 24.0.0 2.8 DN 1H - High flow Pressure drop across valve Position 0.8 0.7 80 70 0.0 2.0.0 4.0.0 6.0 8.0 9.0 9.9 0.08 0.07 0.06 8 7 6 0.04 4 0.074 0.08 0.09 2 266 288 24 7 80 1170 4.16

For calculation of flow rate formula see page 4. DN 1 Measuring signal diagrams DN 1UL - Ultra low flow 0.8 0.7 80 70 Pressure drop across valve 0.02 0.01 2 1 0.00 0.006 0.007 0.008 0.009 0.01 0.02 18.0 21.6 2.2 28.8 2.4 6.0 72.0 8.0 126.0 DN 1L - Low flow Pressure drop across valve 0.02 0.01 2 1 0.01 0.02 0.04 0.06 0.074 6.0 72.0 8.0 144.0 180.0 216.0 266.4 4.17

BOSS TM 900S, 900SC, 901 & 90 DN 1 Measuring signal diagrams DN 1S - Standard flow 0.7 70 Pressure drop across valve 6 0.04 0.06 0.07 0.08 0.09 48 129.6 144.0 180.0 216.0 22.0 288.0 24.0.0 2.8 DN 1H - High flow Pressure drop across valve 0.074 0.08 0.09 2 266 288 24 7 80 1170 4.18

For calculation of flow rate formula see page 4. DN diagrams DN L - Low flow 0.8 0.7 80 70 Pressure drop across valve Position 2.0.0 4.0.0 6.0 7.0 9.9 0.08 0.07 0.06 0.04 8 7 6 4 6 0.04 0.06 0.07 0.08 0.09 48 1 144 180 216 22 288 24 DN S - Standard flow Pressure drop across valve Position 0.8 0.7 80 70 0.0 2.0.0 4.0.0 6.0 7.0 8.0 9.9 0.08 0.07 0.06 0.04 8 7 6 4 0.07 0.09 2 266 24 7 80 1170 4.19

BOSS TM 900S, 900SC, 901 & 90 DN diagrams DN H - High flow 0.8 0.7 80 70 Pressure drop across valve Position 0.0 2.0.0 4.0.0 6.0 7.0 8.0 9.0 9.9 0.08 0.07 0.06 0.04 8 7 6 4 42 11.2 7 80 14 1800 2170 Calculation of flow rate Kvs P Q = 6 where Q = flow rate () P = Signal () Kvs = Signal coefficient 4.

For calculation of flow rate formula see page 4. DN Measuring signal diagrams DN L - Low flow 0.7 70 Pressure drop across valve 6 0.04 0.06 0.07 0.08 0.09 48 1 144 180 216 22 288 24 DN S - Standard flow Pressure drop across valve 0.07 0.09 2 270 24 7 80 1170 DN H - High flow Pressure drop across valve 42 11.2 7 80 14 1800 2170 4.21

BOSS TM 900S, 900SC, 901 & 90 DN 2 diagrams DN 2S - Standard flow 0.8 0.7 80 70 Pressure drop across valve Position 0.0 2.0.0 4.0.0 6.0 7.0 0.08 0.07 0.06 0.04 8 7 6 4 4 4 7 80 14 1800 2170 8.0 9.9 DN 2H - High flow Pressure drop across valve Position 0.8 0.7 80 70 0.0 2.0.0 4.0.0 6.0 7.0 8.0 9.0 9.9 0.08 0.07 0.06 0.04 8 7 6 4 9 0.7 0.8 0.9 1 1.2 44 14 1800 21 2 2880 2 0 4.22

For calculation of flow rate formula see page 4. DN 2 Measuring signal diagrams DN 2S - Standard flow Pressure drop across valve 4 4 7 80 14 1800 2170 DN 2H - High flow Pressure drop across valve 9 0.7 0.8 0.9 1 1.2 44 14 1800 21 2 2880 2 0 4.2

BOSS TM 900S, 900SC, 901 & 90 DN 2 diagrams DN 2H - High flow 0.8 0.7 0.08 0.07 0.06 0.04 80 70 8 7 6 4 Pressure drop across valve Position 0.0 9 0.7 0.8 0.9 1 1.2 44 14 1800 21 2 2880 2 0 2.0.0 4.0.0 6.0 7.0 8.0 9.0 9.9 DN 2 Measuring signal diagrams DN 2H - High flow Pressure drop across valve 9 0.7 0.8 0.9 1 1.2 44 14 1800 21 2 2880 2 0 4.24

For calculation of flow rate formula see page 4. DN diagrams DN H - High flow 0.8 0.7 80 70 Pressure drop across valve Position 0.0 2.0.0 4.0.0 6.0 7.0 8.0 0.08 0.07 0.06 0.04 8 7 6 4 4 0.7 0.8 0.9 1 1.88 184 1800 21 2 2880 2 0 6768 9.0 9.9 DN Measuring signal diagrams DN H - High flow Pressure drop across valve 4 0.7 0.8 0.9 1 1.88 184 1800 21 2 2880 2 0 6768 4.2

BOSS TM 900S, 900SC, 901 & 90 DN diagrams DN H - High flow 0.8 0.7 80 70 Pressure drop across valve Position 0.0 2.0.0 4.0.0 6.0 7.0 0.08 0.07 0.06 0.04 8 7 6 4 0.88 0.9 1 2.1 292 2 0 70 800 1266 8.0 9.0 9.9 DN Measuring signal diagrams DN H - High flow Pressure drop across valve 0.88 0.9 1 2.1 292 2 0 70 800 1266 4.26

Butterfly Venturi Commissioning Valve FODRV & DRV 6mm 0mm (PN16) Balancing Valves BOSS TM 900XSS Venturi FODRV DN6-0 BOSS TM 901XS Venturi DRV DN6-0 The larger sizes of the BOSS TM Venturi consist of a gear operated cast iron butterfly valve fitted with a double regulation feature mounted on a carbon steel tube fitted with the Venturi device. These Venturi valves are available with flanged connections in a long or short pattern. The range covers sizes from 6mm (2 1 2in) to 0mm (12in). This range of valves complement the DZR brass offering of Venturi valves and the long pattern version includes, within the valve, the upstream lengths which are required for accurate commissioning ( times the valve diameter). The flow is calculated based on the pressure differential across the nozzle. The measurement accuracy is better that +/-% and this accuracy is maintained over the entire measuring range from 1 to. The BOSS TM Venturi is available in two variations: FODRV: Includes regulation, isolation and a flow measurement unit. DRV: Includes regulation and isolation unit. Benefits Regulation, Isolation and flow measurement in one single unit Measurement across a nozzle measurement better than +/-% Same measuring accuracy across the entire measuring area from 1 Regulation setting remains unchanged when isolated 4.27

Butterfly Venturi Commissioning Valve (FODRV) Specification The commissioning station incorporates a characterised regulation butterfly valve close coupled to a fixed orifice Venturi flow measuring device with double seal test points. The double regulating feature allows the disc setting to be locked in position using an allen key and return to the exact position after isolation. The long pattern incorporates all upstream lengths required for greater accuracy of flow measurements except when installed in close proximity to a pump. BOSS TM 900XSL Long Pattern Butterfly Venturi DN6-0 FODRV DRV Pressure & Temperature Classification Temperature Max (Max) ºC ºC Pressure Flanged Connection (Max) 16 16 Materials of Construction Venturi pipe Carbon Steel ST7 Measuring P/T plug DZR Brass CW2N CuZn6Pb2As Rubber in P/T plug EPDM Butterfly Valve body Cast Iron, Fully Lugged ASTM A126KL.B Disc Stainless Steel ASTM A1 Shaft Stainless Steel ASTM A276 Backing ring EPDM Drive pin Stainless Steel ASTM A276 Gr16 Shaft seal NBR 1 Bearing Lubricated Bronze ASTM B62 Markings on Valves Venturi pipe Butterfly valve Connection Flanged Compression Pressure Test According to: PN16, ºC, St7 Valve Type, DN & Kvs Value BS44 PN16 EN124-2 ISO8:199E 4.28

Range Butterfly FODRV & DRV DN6-0 FODRV DRV Valve Size Kvs Rates* Signal Head Loss Loss Valve Kvs Kvs Factor Size DN Description m h m h DN m h 6 Standard & Extended 7..00-7.00 8-4 78. 4 6 148 80 Standard & Extended 72.90 6.00-1.00 9-169.00 9 80 27 Standard & Extended 129.00-26.00 9 -.00 12 Standard & Extended 190.00 17.00 -.00-7 2.00 4 12 888 1 Standard & Extended 48.00 24.00-7.00 6 -.00 2 1 241 0 Standard & Extended 86.00 42.00 -.00 7-8 19.00 0.09 0 284 2 Standard & Extended 8 67.00-17.00 8-4 2.00 1 2 449 0 Standard & Extended 11.00 94.00-226.00-29 48.00 0. 0 7761 * The flow rates given in the table are for water flow in steel pipes which provide a pressure loss of to 0 Pa per metre of pipe. Regulation/Operation The valve is adjusted by rotating the hand wheel on the gearbox. The water flow increases when the hand wheel is turned anti-clockwise and reduces when turned clockwise. By using a flow meter or other measuring device the flow rate through the BOSS TM Venturi can be measured and adjusted to meet the specific requirements of the system. The gearbox can be locked against the memory stop when the desired setting is achieved. Once locked the valve can be isolated and when re-opened cannot travel past the memory stop. Isolation The valve is isolated by turning the hand wheel clockwise up to the S position stamped on the gearbox. After isolation the valve is re-opened to the pre-set position when the indicator cam reaches the memory stop. Measurement measurements are via the Venturi nozzle. The BOSS TM Venturi has two test points (P/T plugs). The high pressure test point is identified by the RED retaining clip and the low pressure test point is identified by the BLUE retaining clip. The pressure differential measured between these test points can be used to calculate the actual flow through the Venturi. This differential can be measured using a flow meter or other measuring device. This is converted into a flow rate of litres per second () or metres cubed per hour (m /h) either electronically or using a calculation formula. Valve Sizing Sizing disc available on request via your local BSS branch or BSS technical on 0116 26 702. 4.29

Weights & Dimensions A B D C Standard Butterfly FODRV Venturi DN6 0 Size Nominal A B C D Number Weight Product DN Size in mm mm mm mm of bolts kg Code 6 2 1 2 182 18 28 4 1. 141 80 249 0 29 8 16.2 14121 4 2 2 1 8 2 1412 12 41 2 2 1 8 1414 1 6 4 28 1 8 6 1414 0 8 78 4 0 12 1416 2 411 46 0 12 78 14176 0 12 46 4 2 12 14187 BOSS TM 900XSS Standard Pattern D C BOSS TM 900XSL Long Pattern A B Extended Butterfly FODRV Venturi DN6 0 Size Nominal A B C D Number Weight Product DN Size in mm mm mm mm of Bolts kg Code 6 2 1 2 4 18 28 4 17. 10 80 70 0 29 8 22 114 4 7 2 1 8 4 12 12 86 2 2 1 8 47 16 1 6 28 1 8 6 147 4.

Butterfly Double Regulating Valve (PN16) 6mm 0mm Regulation/Operation The valve is adjusted by rotating the hand wheel on the gearbox. The water flow increases when the hand wheel is turned anti-clockwise and reduces when turned clockwise. The gearbox can be locked against the memory stop when the desired setting is achieved. Once locked the valve can be isolated and when re-opened cannot travel past the memory stop. Isolation The valve is isolated by turning the hand wheel clockwise up to the S position stamped on the gearbox. After isolation the valve is re-opened to the pre-set position when the indicator cam reaches the memory stop. Valve Sizing Sizing disc available on request from your local BSS branch or BSS technical on 0116 26 702. A B BOSS TM 901XS D C Standard Butterfly DRV DN6-0 Size Nominal A B C D Number Weight Product DN Size in mm mm mm mm of bolts kg Code 6 2 1 2 4 18 28 4 6.1 141 80 46 0 29 8 6. 14612 4 2 2 1 8.6 1462 12 2 2 1 8 12.6 1464 1 6 6 28 1 8 14.1 1464 0 8 4 0 12 14.1 1466 2 68 46 0 12.7 14667 0 12 78 4 2 12 48.7 14678 4.1

BOSS TM 900XSS & 900XSL FODRV Venturi Valve DN 6 flange/flange diagram 0.8 0.7 80 70 Pressure drop across valve.0 4.0.0 Position 6.0 7.0 0.08 0.07 0.06 0.04 8 7 6 4 1.8 2 4 6 7 8.0 9.0.0 6.48 7.2.8 14.4 18.0 21.6 2.2 m /h DN 6 flange/flange Measuring signal diagram Pressure drop across valve 1.8 2 4 6 7 6.48 7.2.8 14.4 18.0 21.6 2.2 m /h 4.2

DN 80 flange/flange diagram 0.8 0.7 80 70 Pressure drop across valve Position.0 4.0.0 6.0 7.0 0.08 0.07 0.06 0.04 8 7 6 4 8.0 9.0.0. 4 6 7 8 9 1 12.6 14.4 18.0 21.6 2.2 28.8 2.4 6.0 4.0 m /h DN 80 flange/flange Measuring signal diagram Pressure drop across valve. 4 6 7 8 9 1 12.6 14.4 18.0 21.6 2.2 28.8 2.4 6.0 4.0 m /h 4.

BOSS TM 900XSS & 900XSL FODRV Venturi Valve DN flange/flange diagram 0.8 0.7 80 70 Pressure drop across valve Position.0 4.0.0 6.0 7.0 0.08 0.07 0.06 0.04 8 7 6 4 6.2 7 8 9 26 22. 2.2 28.8 2.4 6.0 72.0 9.6 8.0 9.0.0 m /h DN flange/flange Measuring signal diagram Pressure drop across valve 6.2 7 8 9 26 22. 2.2 28.8 2.4 6.0 72.0 9.6 m /h 4.4

DN 12 flange/flange diagram 0.8 0.7 80 70 Pressure drop across valve Position.0 4.0.0 6.0 7.0 0.08 0.07 0.06 8 7 6 8.0 9.0.0 0.04 4 9 2.4 6.0 72.0 8.0 144.0 m /h DN 12 flange/flange Measuring signal diagram Pressure drop across valve 9 2.4 6.0 72.0 8.0 144.0 m /h 4.

BOSS TM 900XSS & 900XSL FODRV Venturi Valve DN 1 flange/flange diagram 0.8 0.7 80 70 Pressure drop across valve Position 4.0.0 6.0 7.0 0.08 0.07 0.06 0.04 8 7 6 4 16.8 7 6 72.0 8.0 144.0 180.0.0 8.0 9.0 m /h DN 1 flange/flange Measuring signal diagram Pressure drop across valve 16.8 7 6 72.0 8.0 144.0 180.0.0 m /h 4.6

DN 0 flange/flange diagram 0.8 0.7 80 70 Pressure drop across valve Position 4.0.0 6.0 7.0 0.08 0.07 0.06 0.04 8 7 6 4 28 70 80 90 1 8 144 180 216 22 288 24 8.0 9.0 m /h DN 0 flange/flange Measuring signal diagram Pressure drop across valve 28 70 80 90 1 8 144 180 216 22 288 24 m /h 4.7

BOSS TM 900XSS & 900XSL FODRV Venturi Valve DN 2 flange/flange diagram 0.8 0.7 80 70 Pressure drop across valve Position.0 4.0.0 6.0 7.0 0.08 0.07 0.06 0.04 8 7 6 4 41 70 80 90 17 148 180 216 22 288 24 6 8.0 9.0.0 m /h DN 2 flange/flange Measuring signal diagram Pressure drop across valve 41 70 80 90 17 148 180 216 22 288 24 6 m /h 4.8

DN 0 flange/flange diagram 0.8 0.7 80 70 Pressure drop across valve Position 4.0.0 6.0 7.0 8.0 0.08 0.07 0.06 0.04 8 7 6 4 72 80 90 0 226 29 288 24 7 814 9.0.0 m /h DN 0 flange/flange Measuring signal diagram Pressure drop across valve 72 80 90 0 226 29 288 24 7 814 m /h 4.9

Balancing Valves MVS (Modular Valve System) The MVS is a complete flushing bypass system incorporating the BOSS TM Venturi Commissioning Valve Range. It features a variety of interlinked valves and components which are assembled into a system allowing connection, isolation, flushing and draining. Pipe connections are made via Female BSP and terminal connections via flat face male, however pressfit or compression joints are also available. Fully assembled units are tested to BSEN 12266: 0 Prefabricated assemblies for Chilled Water and Heating terminal Units Supports a wide range of configurations Available with connections to most piping systems rates can be adjusted and set through the BOSS TM Venturi Commissioning Range Can be manufactured to include the BOSS TM PICV Test points can be included in the strainer to enable the coil pressure drop to be checked Strainer and Drain Cock are combined in a single unit, as is the ball valve Different components can be selected to attach to the body, depending on site specs The MVS reduces On Site time & labour costs 99mm Centres Technical Specification Maximum Pressure Maximum Temperature Minimum Temperature Body Material 16 1ºC at 6 -ºC at 6 Bronze/DZR Brass Rates Size Rate () DN1UL 0.00 to DN1L 0.01 to 0.074 DN1S 0.062 to 48 DN1H 0.074 to 2 DNL 0.062 to 48 DNS 8 to 2 DNH 6 to 4.

Red Handles - For Heating Applications Size Ball Valve Version Strainer Version DN1UL 229179 229190 DN1L 22906 22994 DN1S 22917 2292 DNL 22928 22911 DNS 2299 229124 DNH 2291 22922 Extended Blue Handles - For Chilled Water Applications Size Ball Valve Version Strainer Version DN1L 229 2291 DN1S 22961 229146 DNL 22972 22917 DNS 2298 229168 DNH 229212 22924 For more information on the BOSS TM MVS please contact your local BSS branch or BSS Technical on 0116 26 702. Typical layout of a multi circuit system Note This sketch is only intended to show possible locations of the commissioning valves, the designer should consider the need for isolating valve for the servicing of pumps, boilers, chillers etc. 4.41

Dynamic PICV 902 (Pressure Independent Control Valve) The BOSS TM Dynamic PICV 902 is a system balancing valve that combines a fixed orifice Venturi and a differential pressure control valve in one body. It is available with or without electrical actuation and has accurate flow measurement and direct flow measuring. When an electrical actuator is installed the PICV incorporates two port valve functionality. The actuators are available in 24VAC/DC On/Off, 2VAC On/Off and 24VDC Modulating Control. Features & Benefits: Direct flow measuring, built in pressure regulator which corrects pressure fluctuations. Full valve authority gives good thermal comfort (when used with a modulating actuator). Can be installed in any position, as long as flow direction is respected. No up/downstream pipe lengths required. Dynamic PICV 902 Dimensions Range A B C Weight Product Size Description Kvs mm mm mm kg Code DN1 Low 0.011-9 76 21906 DN1 Standard 0.78 0.02-2 9 76 21917 DN1 High 2. 0.08-9 9 76 21928 DN Standard 1.9 0.089-4 1 76 0.876 2199 DN High 4.7 2-17 1 76 0.876 219 DN2 Standard 4.98-127 81 6 1. 21961 DN2 High 8. 86-0.92 127 81 6 1. 21972 DN2 High 8. -1.222 127 81 6 1.77 2198 DN Standard 17.* 0.7-2.08 189. 11 8.6 21994 DN High 29.* 6-.47 19 11 8 4.1 2192 * Refers to the Kvm instead of the Kvs valve as this can fluctuate. Technical Specification Material DZR Brass CW2N Maximum Temperature 1ºC Minimum Temperature Minus ºC Maximum Pressure 2Bar Operating Pressure - 0 ( - 4Bar) Connections Female Thread to ISO7/1 Parallel Seals EPDM Membrane Reinforced EPDM Cartridge PPS 4.42

Dynamic Thermotecnic Actuator Actuator Type A B C Weight Product Type Description mm mm mm kg Code BOSS TM 902 24VAC/DC On/Off 8 44 47 4 2191 AT01 2VAC On/Off 8 44 47 18 219146 AE01 24VAC Modulating 44 64 8 21917 Actuator Specification Product Code Product Code Product Code 2191 219146 21917 BOSS TM 902 AT01 AE01 Operating Voltage 24 VAC/DC 0-Hz 2VAC -Hz 24VAC -Hz Operating Power 1.8W 1.8W 2W Base Position Normally Closed Normally Closed Normally Closed Closing & Opening Time mins (approx.) mins (approx.) Control Voltage 0-VDC Acting Force Nm +/-% Nm +/-% Nm +/-% Ambient Temperature 0 - +ºC 0 - +ºC 0 - +ºC Protection Class IP4 IP4 IP4 CE Conformity EN7 EN7 EN7 Cable Grey (1 metre) Grey (1 metre) White (1 metre) 4.4

Dynamic Electromechanical Actuator A 2 B C 74-80 Actuator Type A B C Weight Product Type Description mm mm mm kg Code AVUE 24VAC Modulating 1 76 21921 AVUX 24VAC On/Off 1 76 2192 AVUM 2VAC/DC On/Off 1 76 219242 Actuator Specification Product Code Product Code Product Code 21921 2192 219242 AVUE AVUX AVUM Operating Voltage 24VAC 24VAC 2VAC Operating Power.1 VA 2. VA.6 VA Acting Force 2N 2N 2N Ambient Temperature Operating 0-ºC 0-ºC 0-ºC Storage --70ºC --70ºC --70ºC Protection Class IP IP IP CE Conformity EN 7-1 EN 7-1 EN 7-1 Cable Colour-coded fly lead Colour-coded fly lead Colour-coded fly lead 1.m long, core 1.m long, core 1.m long, core Moulded plastic housing Moulded plastic housing Moulded plastic housing Cable colour: White Cable colour: White Cable colour: White 4.44

Product finder DN H DN S DN 2H DN 2H DN 2S DN H DN vs DN 1H DN 1S 0.01 6 DN 1L 0.02 72 8 0.04 144 0.09 24 0.08 288 0.07 22 0.06 216 180 7 80 14 0 0.9 2 0.8 2880 0.7 2 21 1800 2.0 70.0 800 4.0 I/s 140 I/h 4.4

Dynamic DN 1L female/female diagram % Valve setting 90 80 70 0 0.00 18 0.01 6 0.01 4 0.02 72 0.02 90 8 119.0 Measuring signal 2.0.0 1.0.0.0 0.0 0.00 18 0.01 6 0.01 4 0.02 72 0.02 90 8 119 4.46

Valve setting % 90 80 70 0 0.02 90 126 0.04 162 198 0.06 24 0.07 270 0.08 6 0.09 42 78 1 414 2 4 Measuring signal.0.0 2.0.0 1.0.0.0 0.0 0.02 90 126 0.04 162 198 0.06 24 0.07 270 0.08 6 0.09 42 78 1 414 2 4 DN 1S female/female diagram 4.47

Dynamic DN 1H female/female diagram % Valve setting 90 80 70 0 0.08 288 7 900 80 12 0. 14 2 112.0 Measuring signal 2.0.0 1.0.0.0 0.0 0.08 288 7 900 80 12 0. 14 2 112 4.48

4.49 Valve setting % 90 80 70 0 0.08 288 2 42 4 4 6 76 8 648 7 2 792 4 864 4 882 Measuring signal 2.0.0 1.0.0.0 0.0 0.08 288 2 42 4 4 6 76 8 648 7 2 792 4 864 4 882 DN S female/female diagram

Dynamic DN H female/female diagram % Valve setting 90 80 70 0 7 900 80 12 14 16 1800 1980 21 17 2221 2.0 Measuring signal.0 1.0.0.0 0.0 7 900 80 12 14 16 1800 1980 21 17 2221 4.

4.1 Valve setting % 90 80 70 0 7 900 80 12 14 16 1800 1980 21 2 Measuring signal 2.0.0 1.0.0.0 0.0 7 900 80 12 14 16 1800 1980 21 2 DN 2S female/female diagram

Dynamic DN 2H female/female diagram % Valve setting 90 80 70 0 16 1800 1980 21 2 0.70 2 0.7 2700 0.80 2880 0.8 0.90 2 0.92.0 Measuring signal 1.0.0.0 0.0 16 1800 1980 21 2 0.70 2 0.7 2700 0.80 2880 0.8 0.90 2 0.92 4.2

DN 2H female/female diagram % Valve setting 90 80 70 0 1800 21 0.70 2 0.80 2880 0.90 2 0 0 1. 9 1. 1.22 4 40.0 Measuring signal 1.0.0.0 0.0 1800 21 0.70 2 0.80 2880 0.90 2 0 0 1. 9 1. 4 1.22 40 4.

Dynamic DN S female/female diagram % Valve setting 90 80 70 0 0 1.2 4 1.4 1.6 7 1.8 6480 2.0 70 2.2 79 2.0 Measuring signal.0 1.0.0.0 0.0 0 1.2 4 1.4 1.6 7 1.8 6480 2.0 70 2.2 79 4.4

4. Valve setting % 90 80 70 0 1.4 1.6 7 1.8 6480 2.0 70 2.2 79 2.4 86 2.6 9 2.8 80.0 800.2 11.4 122.6 129 Measuring signal.0 1.0.0.0 0.0 1.4 1.6 7 1.8 6480 2.0 70 2.2 79 2.4 86 2.6 9 2.8 80.0 800.2 11.4 122.6 129 DN H female/female diagram

90 Series DZR Brass Metering Station Description DZR brass metering station Threaded M/F ISO7/1 Rp (F side threaded ISO 228/1 on DN1 and DN) Design according BS7 Tolerance on nominal K vs ±% (test according BS7) PN2 (Max 2 up to C, max at 1 C) Working conditions: Water: - C to +1 C below 0 C only for water with added antifreezing fluids over C only for water with added anti-boiling fluids Materials of Construction N. Part Material Norm 1 Body DZR Brass EN12164 CW2N 2 Venturi insert DZR Brass EN1216 CW2N Test point DZR Brass 1 EN12164 CW2N 1 Test points with EPDM gaskets and polypropylene ties Dimensions and Data DN G 1 H mm L mm BF mm BM mm I mm Weight kg Product Code 01 ULF ½" 7.2.0 17. 1.2 22 19 0.017-0.04 7000184 01 LF ½" 7.2.0 17. 1.2 22 17 1-0.074 700019 01 ½" 7.2.0 17. 1.2 22 1 0.062-48 2 7000 0 ¾".0 62.0 19.0 16. 22 4 8-2 2 7000214 02 1" 6. 67.6 22. 19.1 22 8-2 700022 02 1¼" 69.0 72.4 24.8 21.4 22 6-1.2 2 700026 0 1½" 72.0 72.4 24.8 21.4 22 1 0.8-1.880 2 7000247 0 2" 78.0 82.0 29.2 2.7 22 0.7 1.-. 2 700028 G BF L BM H 1 ISO7/1 Rp (F side threaded ISO 228/1 on DN1 and DN) 2 Suggested flow range applicability (BS7). If used with measuring manometers different from those proposed by BSS please verify that sensibility of the measuring device is compatible with indicated minimum flow (see flow measurement paragraph) I 4.6

Measurement.00.00 0 DN1ULF, K VS venturi DN1LF, K VS venturi 1.1 DN1, K VS venturi 2.80 DN, K VS venturi. DN2, K VS venturi 9.72 DN2, K VS venturi.2 DN, K VS venturi.2 DN, K VS venturi.07 0. 0.001 0.0 0. 00.000.000 Portata [] p TP Formula linking flow Q (in ) and Δp measured at test points (in ). Minimum flow that can be measured for each diameter may be calculated by using in the formula minimum Δp that can be measured by used manometer. Valves are anyway designed for best performances when used on range previously suggested and as indicated by BS7. High pressure test point Low pressure test point Headloss Calculation DN K V m /h 01 ULF 1 01 LF 1.2 01.6 0 7.6 02 1.61 02.78 0 48. 0 8.1 Installation Q (flow) p (headloss) Min xdn (xdn if installed on pump outlet) Q (flow) Formula linking flow Q (in ) and theoretical valve headloss Δp (in ). To obtain the best performances valve must be installed on a pipe with its same nominal size preceded and followed by straight pipe lengths as per figure indications. Min 2xDN 4.7

9 Series DZR Double Regulating Valve Description DZR brass double regulating valve Threaded F/F (ISO 228/1 for DN1 and DN, ISO7/1 RP above) Design according BS7 PN2 (Max 2 up to C, max at 1 C) Water: - C to +1 C below 0 C only for water with added antifreezingfluids over C only for water with addedanti-boiling fluids Materials of Construction N. Part Material Norm 1 Body DZR Brass EN1216 CW2N 2 Balancing cone DZR Brass EN12164 CW2N Gasket disc PTFE 4 Disc 1 DZR Brass EN12164 CW2N Disc O-ring 1 EPDM Perox 6 Disc stem DZR Brass EN12164 CW2N 7 Stem O-ring EPDM Perox 8 Union 1 DZR Brass EN1216 CW2N 9 Stem Brass EN12164 CW617N Bonnet DZR Brass EN12164 CW2N 11 Stop spring ring Spring steel 12 Screw Steel 1 Handwheel ABS (blue) 14 Nut Zinc plated steel EN2 Fe42 1 Only on DN2, DN and DN 4.8

Dimensions and Data DN G 1 H mm L mm B mm 1 ISO 228/1 for DN1 and DN, ISO7/1 Rp above 2 Suggested flow range applicability (BS7). ØV mm Wgt kg range Product Codes 01 LF ½".0 87.8 17. 70 2 0.017-0.074 70007 01 ½".0 87.8 17. 70 27 0.062-48 2 7000118 0 ¾".0 9.9 19.0 70 76 8-2 2 7000129 02 1".0.0 22. 70 0.700 8-2 70001 02 1¼" 12. 117. 24.8 70 1.14-1.2 2 700011 0 1½" 12.4 127.0 24.8 70 1.446 0.8-1.880 2 7000162 0 2" 1.6 14. 29.2 70 2.027 1.-. 2 700017 Headloss Calculation Handwheel Kv (m/h @ 1) position 01 LF 01 0 02 02 0 0 4 96 7 1.41 2.48 2.69 4.99 0.7 4 12 1.66 2.90.07.97 16 4 1 2.04.44.8 7.44 1. 79 1 0.722 2..92 4.16 9.28 1. 18 87 0.80 2.68 4.2 4.7.86 1.7 6 44 0.887.02 4.7.27 12. 2.0 0.72 2.66. 7.0 1. 2. 0.9 0.801 1.14 4. 6.79 9.81 18.9 2. 9 0.8 1.2 4.70 8.08 11.71.21 2.7 0.7 0.9 1.48 4.9 9.2 1.74 21.84.0 79 1.2 2.02.4.92 16. 2.98. 0.741 1.64 2.70.7 11.90 18.14 2.92. 0.78 1.9.16.99 12.1 18.80 27.14.7 0.82 2.14.7 6. 12.67 19. 28. 4.0 0.906 2..9 6. 1.18 19.7 29.67 4.4 0.91 2.6 4.09 6.74 Q (flow) p (headloss) Installation To obtain the best performances valve must be installed on a pipe with its same nominal size preceded and followed by straight pipe lengths as per figure indications. Min xdn (xdn if installed on pump outlet) Min 2xDN 4.9

Presetting of 9 Series By using diagram above is possible to esteem the presetting position of the valve with given design flowrate and headloss: 1) draw a straight line joining design flowrate and design headloss; 2) determine design Kv value as intersection of drawn line and Kv axis; ) draw a straight horizontal line from intersection previously identified and the specific valve DN Axis; 4) intersection determines handwheel position to use for presetting. In the example for a design flowrate of 2,m/h and design Δp handwheel position of 1, is determined for a DN2 valve 4.

Fixed Orifice DZR Brass Commissioning Set 91 Series Description Fixed orifice DZR brass commissioning set Threaded F/F (ISO 228/1 for DN1 and DN, ISO7/1 Rp above) Design according BS7 Tolerance on nominal K vs ±% (test according BS7) PN2 (Max 2 up to C, max at 1 C) Working conditions: Water: - C to +1 C below 0 C only for water with added antifreezing fluids over C only for water with added anti-boiling fluids Materials of Construction N. Part Material Norm 1 Venturi insert DZR Brass EN12164 CW2N 2 Body DZR Brass EN1216 CW2N Balancing cone DZR Brass EN12164 CW2N 4 Gasket disc PTFE Disc 1 DZR Brass EN12164 CW2N 6 Disc O-ring 1 EPDM Perox 7 Disc stem DZR Brass EN12164 CW2N 8 Stem O-ring EPDM Perox 9 Union 1 DZR Brass EN1216 CW2N Stem Brass EN12164 CW617N 11 Bonnet DZR Brass EN12164 CW2N 12 Stop spring ring Spring steel 1 Screw Steel 14 Handwheel ABS (blue) 1 Nut Zinc plated steel EN2 Fe42 16 Test point DZR Brass 2 EN12164 CW2N 1 Only on DN2, DN and DN 2 Test points with EPDM gaskets and polypropylene ties 4.61

Dimensions and Data G 1 H mm L mm B mm ØV mm I mm Wgt kg range Product Codes 01 ULF ½".0 87.8 17. 70 22 8 0.017-0.04 7000011 01 LF ½".0 87.8 17. 70 22 6 1-0.074 7000022 01 ½".0 87.8 17. 70 22 0.062-48 2 70000 0 ¾".0 9.9 19.0 70 22 8-2 2 7000044 02 1".0.0 22. 70 22 0.71 8-2 70000 02 1¼" 12. 117. 24.8 70 22 1.191-1.2 2 7000066 0 1½" 12.4 127.0 24.8 70 22 1.446 0.8-1.880 2 7000077 0 2" 1.6 14. 29.2 70 22 2.064 1.-. 2 7000088 G B L H V 1 ISO 228/1 for DN1 and DN, ISO7/1 Rp above 2 Suggested flow range applicability (BS7). If used with measuring manometers different from those proposed by BSS please verify that sensibility of the measuring device is compatible with indicated minimum flow (see flow measurement paragraph) Measurement DN1 UL,F K VS venturi DN1 L,F K VS venturi 1.1 DN1, K VS venturi 2.80 DN, K VS venturi. DN2, K VS venturi 9.72 DN2, K VS venturi.2 DN, K VS venturi.2 DN, K VS venturi.07 Formula linking flow Q (in ) and Δp measured at test points (in ). Minimum flow that can be measured for each diameter may be calculated by using in the formula minimum Δp that can be measured by used manometer. Valves are anyway designed for best performances when used on range previously suggested and as indicated by BS7. 4.62

Headloss Calculation Handwheel Kv (m/h @ 1) position 01 ULF 01 LF 01 0 02 02 0 0 8 1 1 1.47 2.6 2.72.6 0.7 78 61 1 7 1.7 2.92.12 6.4 4 48 8 2.09.42.69 8. 1. 86 41 2 0.70 2.44.88 4.29.4 1. 0.7 81 0.70 0.78 2.70 4.18 4.82 12.7 1.7 0.78 0.86.01 4.4.71 14.9 2.0 8 0.7 0.86 0.97.7.42 7.78 17.4 2. 42 79 0.9 8 4.18 6.76.4. 2. 47 2 1. 4.7 7.92 12.29 21.7 2.7 6 4 1.14 1. 4.87 9.0 14.1 2.06.0 87 0.716 1.8 1.94.27.6 16.4 24.84. 0.0 0.747 1.6 2.4.61 11.8 17.88 26.44. 14 0.771 1.76 2.9.74 12.06 18.6 27.44.7 1 0.800 1.8.24.88 12. 19.17 28.42 4.0 22 0.824 1.89.1 6.14 12.4 19.9 29.72 4.4 2 0.82 1.92.67 6.24 Calculation of flow rate Kvs P Q = 6 where Q = flow rate () P = Signal () Kvs = Signal coefficient Q (flow) p (Headloss) 4.6

Installation To obtain the best performances valve must be installed on a pipe with its same nominal size preceded and followed by straight pipe lengths as per figure indications. Min xdn (xdn if installed on pump outlet) Min 2xDN 4.64

Presetting of 91 By using diagram above is possible to esteem the presetting position of the valve with given design flowrate and headloss: 1) draw a straight line joining design flowrate and design headloss; 2) determine design Kv value as intersection of drawn line and Kv axis; ) draw a straight horizontal line from intersection previously identified and the specific valve DN Axis; 4) intersection determines handwheel position to use for presetting. In the example for a design flowrate of 2m/h and design Δp 1 handwheel position of 2,9 is determined for a DN2 valve 4.6

Differential Pressure Controls Valves Differential Pressure Controls Valves ½ to 2 (DN1-DN) BOSS TM DPCV and Partner Valve BOSS TM Differential Pressure Control Valves are used to maintain differential pressure. They are available in a number of pressure ranges and sizes depending on the specific requirements of the system. The 1/2 to 1 1/2 valves are supplied with internal female threads (ISO7/1) and the 2 valves are supplied with external male threads (ISO 229/1). The DPCV is mounted on the RETURN and is identified by a blue cap whilst the Partner Valve is mounted on the FLOW and identified by the red cap. Features Protects two port valve authority Maintains circuit loads Partner valve available to connect the impulse tube between flow and return providing isolation, measuring and regulating functions Offers three different differential pressure ranges Shut off function Constant performance Low noise emmission Pressures & Temperatures Maximum Working Pressure 16Bar Maximum Temperature 1ºC Application Pressure Range Pressure Range - 2 - Radiator - - Radiator, Fan Coil, Chilled Beam & Flat Stations - 7-0.7 Fan Coil, Chilled Beam & Flat Stations 4.66

Technical Specification ½ to 2 (D1 to DN) DPCV Differential Weight Product Size DN Pressure Range () Kv Value a L1 H1 H2 D1 D2 c S Kg Code ½ DN1-1.6 Rp ½ 6 2 1 28 61 G¾A 27 0.7 89706 ½ DN1-1.6 Rp ½ 6 2 1 28 61 G¾A 27 0.7 8972 ¾ DN - 2. Rp ¾ 7 128 18 76 G¾A 2 1.1 89717 ¾ DN - 2. Rp ¾ 7 128 18 76 G¾A 2 1.12 89711 1 DN2-4 Rp 1 8 16 2 4 98 G¾A 41 2.00 89728 1 DN2-4 Rp 1 8 16 2 4 98 G¾A 41 2.02 897124 1¼ DN2-6. Rp 1¼ 9 4 29 122 G¾A.6 8979 1¼ DN2-6. Rp 1¼ 9 4 29 122 G¾A. 8971 1¼ DN2-0.7 6. Rp 1¼ 9 4 29 122 G¾A 1.4 89744 1½ DN - Rp ½ 9 1 122 G¾A.69 897 1½ DN - Rp ½ 9 1 122 G¾A.7 897146 1½ DN -0.7 Rp ½ 9 1 122 G¾A 1.7 89744 2 DN - G2½A 1 22 61 1 G¾A n/a 6.1 89761 2 DN - G2½A 1 22 61 1 G¾A n/a 6.8 89717 Technical Specification BOSS TM Adjustment/Partner Valve Differential Weight Product Size DN Pressure Range () Kv Value a L1 H1 H2 D1 D2 c S Kg Code ½ DN1 n/a 1.6 Rp ½ 6 48 1 28 n/a n/a 27 8979 ¾ DN n/a 2. Rp ¾ 7 18 n/a n/a 2 0. 8972 1 DN2 n/a 4 Rp 1 8 7 2 4 n/a n/a 41 0.87 89721 1¼ DN2 n/a 6. Rp 1¼ 9 9 29 n/a n/a 1.7 897242 1½ DN n/a Rp 1½ 1 n/a n/a 1.49 8972 2 DN n/a 16 G2½A 1 6 8 n/a n/a 7 1. 897264 BOSS TM DPCV Partner Valve 4.67

Differential Pressure Controls Valves Differential Pressure Controls Valves 2½ to 4 (DN6 to DNPN16) BOSS TM Partner Valve BOSS TM Differential Pressure Control Valve BOSS TM Differential Pressure Control Valves are used to maintain differential pressure. They are available in a number of pressure ranges and sizes depending on the specific requirements of the system. The 2 1/2 to 4 valves are flanged PN16. The DPCV is mounted on the RETURN whilst the Partner Valve is mounted on the FLOW. Features Protects two port valve authority Maintains circuit loads Partner valve available to connect the impulse tube between flow and return providing isolation, measuring and regulating functions Offers three different differential pressure ranges Shut off function Constant performance Low noise emmission Pressures & Temperatures Maximum Working Pressure 16Bar Maximum Temperature 1ºC Application Pressure Range Pressure Range - - Radiator, Fan Coil, Chilled Beam & Flat Stations - 7-0.7 Fan Coil, Chilled Beam & Flat Stations - - 1 Large Terminal Units i.e Air Handling Units, Fan Coils etc 4.68

Technical Specification 2½ to 4 (DN6 to DN) DPCV Differential L1 H1 H2 D1 D2 D Weight Product Size DN Pressure Range () Kv Value Flanged mm mm mm mm mm mm Kg Code 2½ DN6 - PN16 290 8 9 68 14 42.00 897 DN80-48 PN16 90 68 218 1 48.00 89716 4 DN - 76 PN16 47 446 112 68 248 180 64.44 89727 2½ DN6-0.7 PN16 290 8 9 68 14 42.00 8978 DN80-0.7 48 PN16 90 68 218 1 48.2 89749 4 DN - 0.7 76 PN16 47 446 112 68 248 180 6.00 897 2½ DN6-1 PN16 290 8 9 68 14 41. 89771 DN80-1 48 PN16 90 68 218 1 48.00 89782 4 DN - 1 76 PN16 47 446 112 68 248 180 6.00 8979 Technical Specification BOSS TM Adjustment/Partner Valve Differential Kv L1 H1 H2 0D 0 Weight Product Size DN Pressure Range () Value Flanged mm mm mm mm mm Kg n-0d Code 2½ DN6 n/a 9.4 PN16 290 187 n/a 18 14 4 x 19 17.11 8971 DN80 n/a 122. PN16 n/a 0 1 8 x 19 26 897412 4 DN n/a 0 PN16 222 n.a 2 180 8 x 19 2. 89742 BOSS TM Differential Pressure Control Valve BOSS TM Partner Valve 4.69