Wiring Diagram Index Find product, model #, and wiring diagram # Then find wiring diagrams on pgs.06-7 Architectural Diagram # Accessories NTR-5-6 NTR-5-GFCI- 7 NTR-5-IG-OR- 6 NTR-0-6 NTR-0-GFCI- 7 NTR-0-IG-OR- 6 NT-CJ- NT-PJ- NT-PJ8CJ- 5 NT-PJ8X- 5 NT-PJ8X-, 5 Ariadni Diagram # AY-600P- AY-600PNL- AY-60P-, 6, 7 AY-60PNL-, 6, 7 AY-0P- AY-0PNL- AY-0P-, 6, 7 AY-0PNL-, 6, 7 AYLV-600P- AYLV-60P-, 6, 7 AYF-0P- 8, 9 AYFSQ-F-, 6, 7 AY-LFSQ- 0 Designer Diagram # Accessories CA-PSH- SC-PS- CA-PSH-, 6, 7 SC-PS-, 6, 7 CA-PSH- 7 SC-PS- 7 CAR-5H- 6 SCR-5-6 SCR-0-6 CAR-5-GFCIH- 7 SCR-5-GFCI- 7 SCR-0-GFCI- 7 CA-CJH- SC-CJ- CA-PJH- 5 SC-PJ- 5 Diva Diagram # DVW-600PH- DVW-60PH-, 6, 7 DV-600P- DVSC-600P- DV-60P-, 6, 7 DVSC-60P-, 6, 7 DV-0P- DVSC-0P- DV-0P-, 6, 7 DVSC-0P-, 6, 7 DVELV-00P- DVSCELV-00P- DVELV-0P-, 5 DVSCELV-0P-, 5 DVLV-600P- DVSCLV-600P- DVLV-60P-, 6, 7 DVSCLV-60P-, 6, 7 DVLV-0P- DVSCLV-0P- DVLV-0P-, 6, 7 DVSCLV-0P-, 6, 7 DVF-0P- 8, 9 DVSCF-0P- 8, 9 DVFTU-5AP-, 6, 7 DVSCFTU-5AP-, 6, 7 DVFSQ-F-, 6, 7 DVSCFSQ-F-, 6, 7 DVFSQ-F-HO-, 6, 7 DVSCFSQ-F-HO-, 6, 7 Faedra Diagram # FA-600- FA-600M- 8, 9, 0 FA-000- FA-000M- 8, 9, 0 FALV-600- FALV-600M- 8, 9, 0 FALV-000- FALV-000M- 8, 9, 0 FAELV-500- FAELV-500M-, FA-S6A- FA-S6AM-, FA-AD- 9, 0, FA-AS- Glyder Diagram # GL-600- GL-600P- GL-60P-, 6, 7 GL-000- GL-0P- GL-0P-, 6, 7 GLV-600- GFS-5E- 7, 8 GRAFIK Eye Diagram # 000 Series Unit Power and Wiring 8 Unit to Wallstation Wiring 9 Unit to Unit Wiring 0 000 Series System Wiring GRX-VDC Power-supply Wiring GRX-AV Interface Wiring GRX-RS Interface Wiring 5 Unit to HP- 6 Wiring 6 Power Booster/Interface Wiring 7 Unit to FDBI Power Interface Wiring 8 HP- 6 7 NGRX-PB-WH, 7 ELVI-000, 7 GRX-FDBI-6A-0 5, 8 GRAFIK Eye Diagram # 000 Series Unit Power,, and Wallstation Wiring Interfaces Diagram # HP- 6 6, 7 NGRX-PB-WH ELVI-000 GRX-FDBI-6A-0 5 Maestro Diagram # MAW-600H- MAW-60-RH- 8, 9, 0 MA-600-8, 9, 0 MSC-600M- 8, 9, 0 MA-000-8, 9, 0 MSC-000M- 8, 9, 0 MAELV-600-, MSCELV-600M-, MALV-600-8, 9, 0 MSCLV-600M- 8, 9, 0 MALV-000-8, 9, 0 MSCLV-000M- 8, 9, 0 MA-R- 9, 0, MSC-AD- 9, 0, MA-S8AM-, MSC-S8AM-, MA-AS- MSC-AS- 0 Technical Support Hours/7 Days 800 5 966 www.lutron.com
Wiring Diagram Index Find product, model #, and wiring diagram # Then find wiring diagrams on pgs.06-7 NovaTa Diagram # NT-PS- NT-PS-, 6, 7 NT-PS- 7 NT-600- NT-60P-, 6, 7 NT-000- NT-00P-, 6, 7 NT-500- NT-50P-, 6, 7 NT-000- NTA-- 5 NTB-600-5 NTB-000-5 NTLV-600- NTLV-60P-, 6, 7 NTLV-000- NTLV-00P-, 6, 7 NTLV-500- NTLV-50P-, 6, 7 NTELV-00- NTELV-600- NTF-0-0 NTF-0P- 8, 9 NTFTU-5A- NTFSQ- NTFS-6E- 7, 8 NTFS-E- 7, 8 NT-DPDT-CO-MO- 6 NT-DPDT-CO-MA- 6 Qoto Diagram # Q-600P- Q-60P-, 6, 7 Q-0P- Q-0P-, 6, 7 QLV-600P- QLV-60P-, 6, 7 Q-PS- Q-PS-, 6, 7 RadioRA Diagram # RA-6D- 8, 9, 0 RA-0D- 8, 9, 0 RA-6ND-, RA-5NE-, RA-AD- 9, 0, RA-AS- RALB-5W-RL- RALB-5W-AO- RALB-W-SD- RAMC-5W- RAMC-5W-RL- RAMC-0W- RAMC-0W-RL- RAMC-5W- RAMC-5W-RL- RA-6ND- with ELVI-000/ NGRX-PB-WH RA-6ND- with GRX-FDBI-6A-0 5 RA-8ANS-, RA-GRXI- with GRX-06 9 RA-GRX-- 8-0, -8 RA-GRX-- 8-0, -8 RA-GRX-6-8-0, -8 Skylark Diagram # S-600- S-600P- S-600PNL- S-60P-, 6, 7 S-60PNL-, 6, 7 S-000- S-0P- S-0PNL- S-0P-, 6, 7 S-0PNL-, 6, 7 SLV-600P- SLV-60P-, 6, 7 SELV-00P- SELV-0P-, 5 SF-0P- 0 SF-0P- 8, 9 SFTU-5AP-, 6, 7 SFS-5E- 7, 8 SFSQ-F- SFSQ-F-HO- SFSQ-LF- 7, 8 S-L- 9 S-LF- 0 S-LFSQ- 0 Spacer Diagram # SP-600-HTH- SP-60-HTH- 8, 9, 0 SP-600- SP-600M- 8, 9, 0 SP-000- SP-000M- 8, 9, 0 SPLV-600- SPLV-600M- 8, 9, 0 AD- 9, 0 Spacer Diagram # System SPS-5WC- SPS-5WCR- SPS-600- SPS-600M- 8, 9, 0 SPS-000- SPS-000M- 8, 9, 0 SPSLV-600- SPSLV-600M- 8, 9, 0 SPSLV-000- SPSLV-000M- 8, 9, 0 SPSELV-600- SPSELV-600M-, SPSFTU-5A- SPSF-6A- 0 SPSF-6AM-, SPSF-S6A- SPSF-S6AM-, SPS-AD- 9, 0,, SPS-AS- Vareo Diagram # V-600-8, 9, 0 V-000-8, 9, 0 VF-0-, VETS-000-8, 9, 0 VETS-000-SL-, VETS-A-SL- VETS-R- 9, 0,, 5, VETN-000-,,, 5 Wiring Diagram Index Rotary Diagram # D-600P- D-600R- D-60P-, 6, 7 DNG-600P- DNG-60P-, 6, 7 FSQ-F- FS-5E- 7, 8 FS-5F- To Order/Customer Service 8am 8pm ET (US/CAN) 888 LUTRON 05
Wiring Diagram # Single-pole wiring, Switch, Fan * or * Wiring Diagram # Single-pole wiring of -way control *, Switch, Fan ** ** or Fan ** *** or Fan **or Brass screw terminal **or screw terminal *** or Copper/ screw terminal *** or Brass screw terminal *** or screw terminal or / stripe (cap off) Wiring Diagram # Single-pole wiring with neutral wire connection, Switch or Yellow Wiring Diagram # Single-pole wiring of -way control with neutral wire connection ** Yellow * ** *** or Copper/ screw terminal *** or Brass/Gold screw terminal or / stripe (cap off) Wiring Diagram #5 -way wiring with neutral wire connection Side -Way Switch ** * ** Yellow * * ** *** or Copper/ screw terminal *** or Brass/Gold screw terminal or / stripe (cap off) Note:. Only one dimmer can be used per -way circuit. Follow this diagram when incorporating a -way on/off switch with the dimmer. The -way switch must be wired on line side of the dimmer. 06 Technical Support Hours/7 Days 800 5 966 www.lutron.com
Wiring Diagram #6 -way wiring Line Side, Switch, Fan ** * * -Way Side -Way Switch Switch * ** ** * *** *** OR *** *** or Fan * *, Switch, Fan * ** * or Fan Wiring Diagrams *** or Brass/Gold screw terminal *** or Copper/ screw terminal *** or screw terminal or / stripe Wiring Diagram #7 -way wiring Line Side, Switch, -Way -Way Fan Switch Switch ** * * ** * ** * * *** *** ** * or Fan Side -Way Switch ** * * OR -Way Switch, Switch, Fan ** * ** * * ** * *** or Fan *** or Copper/ screw terminal *** or Brass/Gold screw terminal *** or screw terminal or / stripe To Order/Customer Service 8am 8pm ET (US/CAN) 888 LUTRON 07
Wiring Diagram #8 Single-location wiring of multi-location control, Tapswitch Cap Off Wiring Diagram #9 Line side multi-location wiring Line Side Accessory Accessory Accessory :, Smart, Tapswitch Accessory: Accessory, Auxiliary Tapswitch Up to Nine Total Accessories Wiring Diagram #0 side multi-location wiring Side Accessory Accessory Accessory :, Smart, Tapswitch Accessory: Accessory, Auxiliary Tapswitch Up to Nine Total Accessories 08 Technical Support Hours/7 Days 800 5 966 www.lutron.com
Wiring Diagram # Single-pole wiring of multi-location control with neutral wire connection 0/77VAC Cap Off or Fan Wiring Diagrams :, Smart, Electronic Switch, Tapswitch Wiring Diagram # Line side multi-location wiring with neutral wire connection Line Side Tapswitch Auxiliary Tapswitch Up to Nine Total Auxiliary Tapswitches Wiring Diagram # Multi-location switch wiring with neutral wire connection Side Accessory Accessory Accessory or Yellow 0/77VAC or Fan Up to Nine Accessories :, Smart, Electronic Switch, Tapswitch Accessory: Accessory, Accessory Switch, Auxiliary Tapswitch To Order/Customer Service 8am 8pm ET (US/CAN) 888 LUTRON 09
Wiring Diagram # Vareo switch wiring with neutral wire connection Line Side VETS-000-SL VETS-A-SL VETS-A-SL or Fan Up to Four Total VETS-A-SL Units Side VETS-A-SL OR VETS-A-SL VETS-000-SL or Fan Up to Four Total VETS-A-SL Units Wiring Diagram #5 Omnislide wiring Base Line Side Base Auxiliary Base Side Auxiliary Base OR 0 Technical Support Hours/7 Days 800 5 966 www.lutron.com
Wiring Diagram #6 AC motor wiring of double-pole, double-throw switch Motor Lower Raise Rear View of NT-DPDT-CO-MO-, NT-DPDT-CO-MA- A L B A L B Lower Raise Motor Wiring Diagrams Wiring Diagram #7 Single-pole wiring, fan only Fan Wiring Diagram #8 Single-pole wiring, fan and light Fan to Fan Yellow (Cap off) * Fan Yellow to Light * Incandescent Fan * Switched full voltage only * Switched full voltage only Wiring Diagram #9 Single-pole wiring, dual light control Dual Light Wiring Diagram #0 Single-pole wiring, dual fan/light control Dual Yellow to Fan Yellow to Light Fan To Order/Customer Service 8am 8pm ET (US/CAN) 888 LUTRON
Wiring Diagram # Wall-mounted master control wiring Master Rear View of Spacer System s and SPS-5WC- Ganged Together << >>>>>>>> SPS-5WC- emits signal that travels up to dimmers in either direction. Wiring Diagram # Remote-mounted master control wiring with infrared blaster Wall-Mounted Master Spacer System Infrared Blaster Master / Stripe Traveler / Stripe / Stripe Traveler / Stripe Rear View of 5 Spacer System s Ganged Together < < < > > > Spacer System Wallbox Wallbox Spacer System Infrared Blaster (Optional) Infrared Blaster emits signal that travels up to dimmers in either direction. Traveler / Stripe Traveler / Stripe Spacer System Wallbox Technical Support Hours/7 Days 800 5 966 www.lutron.com
Wiring Diagram # Cable jack wiring Cable Jack 75-Ohm Cable 75-Ohm Cable Wiring Diagram # Telephone jack wiring, 6-conductor 6-Conductor Telephone Jack* Jack Position * accepts most -conductor jacks Wire Color 5 Yellow 6 Wiring Diagrams Wiring Diagram #5 Telephone jack wiring, 8-conductor 8-Conductor Telephone Jack* Wire Color 5 6 Yellow 7 Brown 8 Jack Position * accepts most - or 6-conductor jacks Wiring Diagram #6 Receptacle wiring Brass Screws Receptacle (5A Shown) Nickel Plated Screws **for split circuit wiring, break off tab on brass side only * Screw Building (to metal box) or Isolated Wiring Diagram #7 GFCI receptacle wiring Receptacle (5A Shown) Not Protected GFCI Receptacle (5A Shown) Protected Brass Screws Receptacle (5A Shown) Protected Nickel Plated Screws To Order/Customer Service 8am 8pm ET (US/CAN) 888 LUTRON
Wiring Diagram #8 Single-pole wiring of -way, -wire fluorescent control Yellow or Violet or * or Brown ** * Dimming Ballast or Brown ** Dimming Ballast To Additional Ballasts *** must use lamp disconnect sockets with magnetic dimming ballasts *** or Yellow/ or Yellow/ when used with magnetic dimming ballasts Wiring Diagram #9 -way wiring of -wire fluorescent control Side -Way Switch* Violet or Yellow or ** or Brown *** Dimming Ballast ** or Brown *** Dimming Ballast To Additional Ballasts * -Way switch must be wired on line side of dimmer *** must use lamp disconnect sockets with magnetic dimming ballasts *** or Yellow/ or Yellow/ when used with magnetic dimming ballasts or Copper/ screw terminal or Brass/Gold screw terminal Technical Support Hours/7 Days 800 5 966 www.lutron.com
Wiring Diagram #0 Single-pole wiring of -wire fluorescent control Yellow or or Brown * ** or Brown * ** Dimming Ballast Dimming Ballast Wiring Diagrams To Additional Ballasts *** or Yellow/ or Yellow/ when used with magnetic dimming ballasts *** must use lamp disconnect sockets with magnetic dimming ballasts Wiring Diagram # Single-pole wiring of multi-location -wire fluorescent control To Additional Ballasts Dimming Ballast Dimming Ballast Wiring Diagram # Multi-location wiring of -wire fluorescent control Side Accessory Accessory Up to Nine Total Accessories Accessory: Accessory, Auxiliary Tapswitch To Additional Ballasts Dimming Ballast Dimming Ballast To Order/Customer Service 8am 8pm ET (US/CAN) 888 LUTRON 5
Wiring Diagram # Single-pole wiring of magnetic dimming ballast control For more information about products that control magnetic dimming ballasts contact Lutron Customer Service. Yellow Brown * ** Brown * ** Fixture equipped with Magnetic Dimming Ballast Fixture equipped with Magnetic Dimming Ballast To Additional Ballasts ** or Yellow/ or Yellow/ ** must use lamp disconnect sockets with magnetic dimming ballasts Wiring Diagram # Power Booster (PB) and Electronic Low-Voltage Interface (ELVI) wiring Rear View of PB/ELVI Zone Out /Live Earth/ Zone In N to From Distribution Panel Wire single-pole, -way, or multi-location dimmer as normal except run the load wire to the PB/ELVI zone in terminal. s 6 Technical Support Hours/7 Days 800 5 966 www.lutron.com
Wiring Diagram #5 Fluorescent Dimming Ballast Interface (FDBI) interface wiring Wiring Diagrams SW /Live Zone In N Rear View of FDBI Zone Out /Live Earth/ to From Distribution Panel *** or Yellow/ or Yellow/ when used with magnetic dimming ballasts *** must use lamp disconnect sockets with magnetic dimming ballasts Dimming Ballast Dimming Ballast Wire single-pole, -way, or multi-location dimmer as normal except run the load wire to the FDBI zone in terminal. or Brown * ** or Brown * ** To Additional Ballasts To Order/Customer Service 8am 8pm ET (US/CAN) 888 LUTRON 7
Wiring Diagram #6 Single-pole wiring to a Hi-Power 6 dimming module Hi-Power 6 Circuit Terminals N N H H DH From Distribution Panel /Live To additional HP 6 Dimming Modules (Five Maximum) Single-Pole /Live Dimmed Wiring Diagram #7 -way wiring to a Hi-Power 6 dimming module Hi-Power 6 Circuit Terminals N N H H DH From Distribution Panel /Live To additional HP 6 Dimming Modules (Five Maximum) or / -Way Switch /Live Dimmed 8 Technical Support Hours/7 Days 800 5 966 www.lutron.com
Wiring Diagram #8 GRAFIK Eye 000 Series control unit power and load wiring Earth/ from Distribution Panel Distribution Panel # AWG Zone Zone Zone 5 Zone Zone CU Wire Only Zone 6 # AWG # AWG # AWG 5 # AWG # AWG 6 # AWG /Live (.5mm ) (.5mm ) USA Class IEC PELV /Live CLASS (.5mm ) /Live Rear View of GRAFIK Eye Unit (GRX-06 shown) Note:. Each line voltage terminal can accept up to two # AWG (.5mm ) wires.. Each Class /PELV terminal can accept up to two #8 AWG (.0mm ) wires.. For non-dim relay wiring, see GRAFIK SYSTEMS Technical Reference Guide, P/N 60-95. For load-side emergency transfer wiring, see GRAFIK SYSTEMS Technical Reference Guide, P/N 60-95 5. Input wiring for Lutron Tu-Wire ballasts is the same as wiring shown above for loads -6. Wiring Diagrams To Order/Customer Service 8am 8pm ET (US/CAN) 888 LUTRON 9
Wiring Diagram #9 GRAFIK Eye 000 Series control unit to wallstation wiring Earth/ from Distribution Panel Rear View of GRAFIK Eye Unit (GRX-06 shown) Distribution Panel /Live # AWG (.5mm ) Line Voltage Wiring /Live Class /PELV Wiring : Common : VDC Zone Zone CU Wire Only Zone 6 Lutron Cable, GRX-CBL-6S (non-plenum) /Live CLASS USA Class IEC PELV Data Link : MUX : MUX Zone Zone Zone 5 Wallstation Wallstation Wallstation 56 56 56 NTGRX-S (0 Maximum) Note:. For other possible NTGRX-S wiring configurations, see GRAFIK Eye Application Notes available at www.lutron.com.. The NTGRX-S is for use with -, -, and 6-zone control units only.. Each control unit can power up to three Class /PELV wallstations/control interfaces. If more than three need to be connected to one control unit, install an external VDC power supply as shown in Wiring Diagram #.. Class /PELV non-plenum cable is available from Lutron, order GRX-CBL-6S-500 (non-plenum rated cable) or GRX-PCBL-6S-500 (plenum-rated cable). 0 Technical Support Hours/7 Days 800 5 966 www.lutron.com
Wiring Diagram #0 GRAFIK Eye 000 Series control unit to control unit wiring Rear View of GRAFIK Eye Unit (GRX-06 shown) Rear View of GRAFIK Eye Unit (GRX-06 shown) Zone Zone Zone 5 Zone Zone CU Wire Only Zone 6 Zone Zone Zone 5 Zone Zone CU Wire Only Zone 6 USA Class IEC PELV /Live CLASS USA Class IEC PELV /Live CLASS Note:. Each control unit has its own power supply.. Do not connect terminal No. when wiring between GRAFIK Eye 000 Series control units.. Class /PELV cable is available from Lutron, order GRX-CBL-6S-500 (non-plenum rated cable) or GRX-PCBL-6S-500 (plenum-rated cable). Wiring Diagram # GRAFIK Eye 000 Series control unit wiring and NTGRX-S- wallstation wiring Earth/ from Distribution Panel Distribution Panel # AWG Zone Zone Zone Zone CU Wire Only # AWG # AWG # AWG (.5mm ) (.5mm ) # AWG /Live USA Class IEC PELV /Live CLASS (.5mm ) /Live Rear View of GRAFIK Eye Unit (GRX-06 shown) Note:. The NTGRX-S- is for use with -zone and -zone control units only. NTGRX-S (0 Maximum) Wiring Diagrams To Order/Customer Service 8am 8pm ET (US/CAN) 888 LUTRON
A A 5 A and A have their own power supplies No terminal No. connection A powers Wallstations,, and No terminal No. connection between Wallstations and 5 6 Total Class /PELV wiring length is,000 (600m) maximum Maximum length of T-tap is 8 (.5m) A powers only terminal No. connection terminates at Wallstation 7 A powers Wallstations 5, 6, and 7 A A Wiring Diagram # GRAFIK Eye 000 Series system wiring Rear View of GRAFIK Eye Unit (GRX-06 shown) Rear View of GRAFIK Eye Unit (GRX-06 shown) Rear View of GRAFIK Eye Unit (GRX-06 shown) No terminal No. connection between Wallstations and 5 Rear View of GRAFIK Eye Unit (GRX-06 shown) Note:. Each control unit can power up to three Class /PELV wallstations/control interfaces. If more than three need to be connected to one control unit, install an external VDC power supply as shown in Diagram #.. Do not connect terminal No. between GRAFIK Eye 000 Series control unit and GRX-VDC power supply.. Up to eight GRAFIK Eye 000 Series control units and 6 wallstations/control interfaces can be daisy chained together in one system.. Class /PELV non-plenum cable is available from Lutron, order GRX-CBL-6S-500 (non-plenum rated cable) or GRX-PCBL-6S-500 (plenum-rated cable). Technical Support Hours/7 Days 800 5 966 www.lutron.com
Wiring Diagram # GRAFIK Eye 000 Series GRX-VDC power-supply wiring Wiring Diagrams Rear View of GRAFIK Eye Unit (GRX-06 shown) Zone Zone CU Wire Only Zone 6 Zone Zone Zone 5 Lutron cable, GRX-CBL-6S (non-plenum) /Live CLASS USA Class IEC PELV Wallstation 56 Wallstation 56 One twisted pair #8 AWG (.0mm ) Two twisted pair #8 AWG (.0mm ) Wallstation Wallstation 56 56 One #8 AWG (.0mm ) To Power Source Common (+) VDC Wallstations/ Interfaces (6 Maximum) GRX-VDC Note:. Do not connect terminal No. between GRAFIK Eye 000 Series control unit and GRX-VDC power supply.. Class /PELV non-plenum cable is available from Lutron, order GRX-CBL-6S-500 (non-plenum rated cable) or GRX-PCBL-6S-500 (plenum-rated cable). To Order/Customer Service 8am 8pm ET (US/CAN) 888 LUTRON
Wiring Diagram # GRAFIK Eye 000 Series GRX-AV control interface wiring /Live Zone Zone Zone CU Wire Only CLASS Rear View of GRAFIK Eye Unit (GRX-0 shown) USA: Class IEC: PELV Lutron Cable, GRX-CBL-6S Customer-Supplied Equipment Input Input Input Input Input 5 Output Output Output Output Output 5 Power Supply 5 + V LEDs (Status Lights) MUX Link COM +V MUX MUX Program Switch C 5 5 C Inputs Outputs GRX-AV To additional Wallstations/ Interfaces (6 Maximum; three from one Unit without external VDC power supply) Wiring Diagram #5 GRAFIK Eye 000 Series GRX-RS control interface wiring /Live Zone Zone Zone CU Wire Only CLASS Rear View of GRAFIK Eye Unit (GRX-0 shown) USA: Class IEC: PELV Lutron Cable, GRX-CBL-6S MUX Link 50' (5m) Maximum 5 RS Link COM TxD RxD GRX-RS/GRX-PRG PC Computer or Audio/Visual Equipment To additional Wallstations/ Interfaces (6 Maximum; three from one Unit without external VDC power supply) Technical Support Hours/7 Days 800 5 966 www.lutron.com
Wiring Diagram #6 GRAFIK Eye 000 Series control unit to Hi-Power 6 wiring Feed from Distribution Panel To additional loads Circuit Feed: /Live Dimmed /Live Zone Zone Zone Hi-Power 6 5 Circuit Terminals CU Wire Only N N H H DH CLASS USA: Class IEC: PELV To additional HP 6 Modules (Five Maximum) Wiring Diagrams Rear View of GRAFIK Eye Unit, (GRX-0 shown) Note:. circuit feed is shown coming from the GRAFIK Eye control unit feed. The load on the dimmer for each Hi-Power 6 module connected is 0W/VA. Hi-Power 6 has a special active load which will meet the minimum load requirements for any Lutron dimmer. If the circuit does not have sufficient capacity to support the load of the module(s), the Hi-Power 6 control circuit feed can be supplied from any circuit with sufficient capacity as long as it is on the same phase as the GRAFIK Eye control unit. Do not use Hi-Power 6 with generator-supplied power.. type should be set as incandescent on the GRAFIK Eye control unit.. Dimmed hot is shown connected to Zone in the diagram, but can be connected to any zone on the control unit.. For GRAFIK Eye 000 Series control units, refer to GRAFIK Eye 000 Instruction Sheet (P/N 0-08) for the remainder of control unit wiring. 5. Refer to Hi-Power 6 Instruction Sheet (P/N 00-5) for the remainder of Hi-Power 6 wiring. To Order/Customer Service 8am 8pm ET (US/CAN) 888 LUTRON 5
Wiring Diagram #7 GRAFIK Eye 000 Series control unit to PB/ELVI power booster/interface wiring Wiring Diagram #8 GRAFIK Eye 000 Series control unit to FDBI power interface wiring Rear View of PB/ELVI /Live Zone Zone Zone CU Wire Only /Live Feed from Distribution Panel /Live Feed from Distribution Panel /Live Feed from Distribution Panel Zone Out /Live Earth/ SW /Live Zone In Lutron Dimming Ballast Rear View of FDBI Earth/ Rear View of GRAFIK Eye Unit (GRX-0 Shown) USA: Class IEC: PELV USA: Class IEC: PELV Zone Out Live Earth/ Do Not Use Zone In N Rear View of GRAFIK Eye Unit (GRX-0 Shown) /Live Feed from Distribution Panel Note:. Each terminal can accept up to two #AWG (.5mm ) wires.. PB/ELVI /Live can be on the same phase or different phase than the GRAFIK Eye 000 Series control unit /Live.. Up to two PB/ELVI interfaces can be wired to a single GRAFIK Eye zone. Note:. Each terminal can accept up to two # AWG (.5mm) wires.. FDBI /Live can be on the same phase or different phase than the GRAFIK Eye 000 Series control unit /Live.. Lutron Tu-Wire ballasts do not require the use of FDBI Power Interface.. Up to two FDBI interfaces can be wired to a single GRAFIK Eye zone. /Live Zone Zone Zone CU Wire Only 6 Technical Support Hours/7 Days 800 5 966 www.lutron.com
Wiring Diagram #9 RadioRA /GRAFIK Eye interface wiring RA-GRXI with GRX-06 (typical) GRX-06 Zone Zone Zone 6 /Live Class /PELV Power Wiring : Common : VDC Class USA CLASS IEC PELV Data Link : MUX : MUX Zone Zone Zone 5 RadioRA/ GRAFIK Eye Interface Wiring Diagrams Yellow Wiring Diagram #50 GRAFIK Eye 000 Series control unit to GRX-IRI infrared interface Rear View of GRAFIK Eye Unit (GRX-500 shown) Zone Zone Zone 6 CU Wire Only Zone Zone Zone 5 /Live CLASS Class /PELV Wiring : Common : VDC Lutron Cable, GRX-CBL-6S (non-plenum) USA Class IEC PELV Data Link : MUX : MUX GRX-IRI To additional Wallstations Infrared Transmitter (Provided by others) To Order/Customer Service 8am 8pm ET (US/CAN) 888 LUTRON 7