660R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev F

Similar documents
320R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev.

120RMAM Marine Series Fuel Filter/Water Separators

Product Features: Removes 99% of free water. Available with 2, 10, or 30 micron Aquabloc II media

75500MAX Series and 75500MAXM Series

Racor 75500FGX Turbine Series fuel

400 Series Spin-on Fuel Filter/Water Separators

Marine Gasoline Products

Product Features. Easy installation. Pump adds only 3.3 to the overall assembly height. 60 GPH (227 LPH) flow rate while in priming mode.

900MA/MAM and 1000MA/MAM (for marine applications)

Marine Fuel Filtration Marine 800 Series

Marine Fuel Filtration. Marine FBO. Features:

Marine Fuel Filtration. Marine Turbine Series. Stage One: Separation. Stage Two: Coalescing. Stage Three: Filtration. And more

General The Racor Marine Diesel Spin--on Series feature a variety of compact sizes to fit most installations and cramped engine compartments.

All Racor filter materials and seals are compatible with ultra-low sulphur diesel (ULSD) fuel and B2 to B20 Biodiesel. See Racor bulletin 7679.

Marine Turbine Series

Gasoline Fuel Filters. For Marine Applications

900FH and 1000FH Turbine Series Fuel Filter/Water Separators Installation, Operation, and Service Information

Introduction. Marine Turbine Series. Model Illustrations. Special Notes. Specifications 77/1000MA 73/1000MA 75/500MAX 75/900MAX 79/1000MAV 75/1000MAX

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

Maintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

Section: B Marine Fuel Filtration

Maintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC

MARINE. Diesel Fuel/Water Separators. Installation. Operation. Parts. Service Information

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

18324 INSTALLATION INSTRUCTIONS 65 PONTIAC LEMANS

DY Series 1-Piece Ball Valves. Catalog 1001C-A. July 2012 欧陆传动

High Pressure Gear Pumps & Motors Series PZG Pumps Series MZG Motors

GARDEN HOSE UTILITY PUMP

Gauge Adapter Instruction Manual

PARTS AND INSTALLATION MANUAL

INSTRUCTION MANUAL G-Surge Tank #40007, #40008 & #40009

Viscount I Hydraulic Motor and Displacement Pump

Installation & Service Instructions

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

Operation and Maintenance Manual

Models P, P, P, , DANGER

FPS-500. Fuel Polishing System Eliminates Microbial Contamination. Operating Manual

Figure 1: HB Series Ball Valve Cross Sectional View DISASSEMBLY WARNING: MAKE CERTAIN THE SYSTEM IN WHICH THE VALVE IS INSTALLLED IS EXHAUSTED OF ALL

Manifold w/ Needle Valve Instruction Manual

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

11101, & INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # Mustang 5.0L Fuel System Kit INSTALLATION INSTRUCTIONS

BMK-30. Heavy-Duty By-Pass Filtration System Installation and Servicing Instructions

M39075 ( IF- 1) Integra- Fuse Rivet Tool

Pulse Width Modulation Valves. Models SPW-0 thru -7

Dual/Triple Manifold Water Filtration Systems Instruction Manual

AEROMOTIVE Part # CHEVY/GMC Duramax Fuel System Kit RETRO FIT KIT FOR ½ LINES INSTALLATION INSTRUCTIONS

D Instructions/Parts. Siphon Feed Detail Spray Gun D

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

FUEL KITS P/N & 526-4

Operating and Installation Instructions

Installation and Maintenance Manual

Owner s Manual Supplement. Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.

AEROMOTIVE Part # Generic EFI Fuel System INSTALLATION INSTRUCTIONS

Fuel Pro Series Filter/Separator/Warmer Installation Instructions

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Voltmaster Centrifugal Trash Pumps

Flow Control Valves Check Valves Gauge Control Valves. Colorflow Valves

11104 & Installation Instructions

Operating instructions Form no safety definitions

T1-Titanium Non-HVLP Spray Gun

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

FOR TECHNICAL ASSISTANCE

STC 2L Series Solenoid Valves

SHOP PRO FXP 95 TECHNICAL MANUAL

# and # FAST Fuel System Kits

Sinclair Collins. Process Control Valves. For Steam, Hot and Cold Liquids -40 to 450 F up to 500 psi. Catalog SCV-100/USA April 2001

Moduflow Series IL2/RF2/CF2 Low Pressure Filters

Moduflow. ILP and RFP Low Pressure Filters. Series

HP-100 Dual-Flo Petroleum Hand Pump

Pneumatic High-Viscosity Filtration System Instruction Manual

AEROMOTIVE Part # & Generic Fuel System Kit INSTALLATION INSTRUCTIONS

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Installation, Operating and Maintenance Manual

18660, 18661, & Stealth Fuel Cell INSTALLATION INSTRUCTIONS

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

SNAPP. The One-Piece, High-Performance Snap-In Fuel Filter Water Separator

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

Lube Level Maintainer

STC 2W Series Solenoid Valves

SUBMERSIBLE SUMP PUMPS

FOR TECHNICAL ASSISTANCE

AEROMOTIVE Part # FORD POWERSTROKE Fuel System Kit INSTALLATION INSTRUCTIONS

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Dual Flow Manifold Systems Instruction Manual

Models GP5132, GP5136, GP5142 & GP5145. Triplex Ceramic Plunger Pump Operating Instructions / Manual

3V SERIES SOLENOID VALVE

WARNING User Responsibility

PORTABLE TRASH PUMPS MTP200 MTP300 MTP400

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

18318 INSTALLATION INSTRUCTIONS CHEVROLET IMPALA

SHOP PRO FXP TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT TABLE OF CONTENTS

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

Installation and Startup Manual Hydraulic Pumps Series VP1-095 /-110/ -130

SNAPP. The One-Piece, High-Performance Snap-In Fuel Filter Water Separator. Next

SHOP PRO ST TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT TABLE OF CONTENTS

Transcription:

660R-RAC Series Gasoline Fuel Filter/Water Separators Instruction Part Number 1385 Rev F Overview: Don t be caught in the water without one of these Racor gasoline spin on series filters. These filters are designed for high-performance applications, which means your engine will perform better than ever with clean, water-free fuel. The spin-on filter is simple to replace and reuseable clear plastic (or metal) contaminant collection bowl features a self-venting drain (or metal plug) for removing unwanted muck and water. Contact Information: Parker Hannifin Corporation Racor Division P.O. Box 308 3400 Finch Road Modesto, CA 95353 phone 800 344 386 09 51 7860 fax 09 59 378 racor@parker.com www.parker.com/racor Product Features: Removes 99% of free water 660R-RAC-0 is UL listed and USCG approved for inboard marine use 4-port, die-cast aluminum mounting head with 3/8-18 NPTF threads 90 GPH (340 LPH) maximum flow rate Superior corrosion resistance with electrostatic powder coating High-capacity, 10 micron Aquabloc II media

Mounting Instructions Top View OUT OUT.5 in. (5.7 cm) IN IN 3/8 (1.0 cm) diameter clearance for fasteners Installation Diagram Optional Bypass Installation and Operation (allows user to service filter without shutting down engine.) Fuel Tank (Pressure Side Installation) Pressure Side: Fuel transfer pump not to exceed maximum PSI or flow rate of filter. Not ideal - pumps emulsify water hindering filter performance. Valves 1 3 Unit On-line Open Open Closed Unit Off-line Closed Closed Open Suction (vacuum) Side: Primary (first) filter - use 30 micron. If it is the only filter in the system, use or 10 micron. Fuel Tank (Ideal Vacuum Side Installation) Valve Engine Install a check valve (with light or no restriction) when tank is lower than filter to main prime. Fuel Tank (Vacuum Side Installation) Fuel tank below filter Do not exceed 5 (1.5m) of lift or 4 inches of mercury (inhg) of inlet piping restrictions Valve 3 Maintain a service clearance below filter assembly of at least 1 in. (.5 cm) for draining and servicing the bowl. Fuel transfer pump (IDEAL vacuum side installation)

Installation Guidelines Danger! Great care must be exercised to avoid potential fire hazards during installations on gasoline fuel systems. Do not smoke or permit open flames or sparks near the fuel system. 1. Any secondary or pressure side filters located between the pump and engine should be serviced and left in place.. Mount the unit vertically on the suction side of fuel pump, transfer pump, or nonremovable filters, whichever comes first. 3. Ensure a suitable pipe thread sealing compound is used on the NPT threads of fitting prior to installation into the head. For mounting flexibility there are two inlet ports and outlet ports. Plated steel fittings are recommended. Plug unused ports with the provided steel NPT plugs - Do not use thread tapes on NPT threads. 4. Use quality fuel hose in the maximum fuel line size applicable to reduce potential fuel flow restrictions. Note: USCG accepted hose recommended. Contact your Racor distributor for your application requirements. Priming The Unit 1. Carefully spin-off bowl/ element as one and fill both with clean fuel (use a strap wrench near top of element to remove and avoid damage).. Spin Bowl/Element onto mounting head and tighten snugly by hand - do not use tools to tighten. 3. Start engine and check for any leaks. If engine is difficult to start or runs rough, check that drain, bowl, element and port plug are securely tightened. Check all connections for security and hoses to ensure there are no kinks or sharp bends that would create excessive restriction. Service Danger! When servicing gasoline fuel systems, extreme care must be exercised to avoid potential fire hazards. Do not smoke or permit open flames near fuel system during servicing procedures. Draining the Collection Bowl Water is heavier than fuel and will settle at bottom of bowl and appear a different color. In extremely humid conditions, take a fuel sample (in clear container) frequently, daily, if needed and drain as required if water is present. 1. Place a suitable container below unit to collect contaminants.. Close fuel tank valve (if applicable), then open Racor self-venting drain (or loosen/ remove drain plug) at bottom of bowl. Note: a UL listed drain valve kit is available for 0 models, order part no. RK 1949. 3. Prime the fuel system following the manufacturer s procedure - refer to Priming The Unit. Element Replacement Element replacement frequency is determined by contamination levels in fuels. Fuel flow to engine becomes restricted as element slowly plugs with contaminants, resulting in noticeable power loss and/or hard starting. Replace element annually, every 100 hours, or when there is a noticeable power loss, whichever comes first. Change element as soon as possible. Note: Always carry extra replacement elements as one tankful of excessively contaminated fuel can plug a fuel filter. Clean any debris or dirt away from Racor head/filter joint prior to removal. 1. Place a suitable container below unit to collect contaminants.. Close valve at fuel tank (if applicable) open or remove drain (plug) to empty Racor filter of fuel. 3. Spin element and bowl off together (use a strap wrench on element), then remove bowl from element. 4. Clean, bowl O-ring gland and sealing surface of mounting head, of dirt, debris or gums. 5. Apply lube oil to new seal and bowl O-ring supplied with element. 6. Place new seal onto top of new element and O-ring into bowl gland. 7. Spin bowl onto element, and then both onto head. Tighten snugly by hand do not use tools to tighten. 8. Prime fuel system following manufacturer s procedure - refer to Priming The Unit.

Troubleshooting Procedures A major cause of power loss or hard starting is result of an air leak (or clogged filter). If your filter will not prime or fails to hold prime, check that drain, bowl and filter are properly tightened. Next, check all fitting connections and ensure fuel lines are not pinched or clogged with contaminants. If problems persist (and filter is new) call Racor Technical Support for assistance: 800 344 386 or 09 575 7555. Applies to all models Specifications 660R-RAC-01 660R-RAC-0 Application: Inboard Outboard Maximum Flow Rate 90 GPH (340 LPH) 90 GPH (340 LPH) Center Threads 1-14 1-14 Port Size 3/8-18 NPTF 3/8-18 NPTF Number of Ports: Inlets Outlets Height 11.0 in. (7.9 cm) 10.5 in. (6.7 cm) No Yes Yes Yes Width 4. in. (10.7 cm) 4. in. (10.7 cm) Depth 4.5 in. (11.4 cm) 4.5 in. (11.4 cm) Weight (dry) 3.0 lb (1.4 kg) 3.0 lb (1.4 kg) Clean Pressure Drop 0.61 PSI (4.3 kpa) 0.61 PSI (4.3 kpa) Maximum Pressure 7 PSI (0.5 bar) 7 PSI (0.5 bar) Underbowl Clearance 1.0 in. (.5 cm) 1.0 in. (.5 cm) Water Removal Efficiency 99% 99% Ambient Temperature Range -40 to +55 F (-40 to +14 C) Maximum Fuel Temperature 190 F (3 C)

Accessories Vacuum Gauges Vacuum gauges are available to monitor element condition and as the filter element slowly becomes clogged with contaminates the restriction (resistance to flow) increases. The fuel pump still tries to draw fuel (suction) but because of restriction, less fuel is delivered to engine and instead more air is pulled from it (fuel de-gassing). Results can cause engine to lose power and eventually stall. By installing a vacuum gauge in the fuel system on the outlet side of the filter, visual monitoring of element condition is possible. Specifications Description Threads Dimensions Dial Weight 1606B Includes gauge and two fittings. Instrument panel installation. 1/4 NPT back bracket mount..0 W x 1.9 D in. 0.4 lb (0. kg) Special Notes: For severe vibration applications, mount gauge on stable, remote location and connect using flexible tubing. Additional gauges available - contact your local distibutor. Hose Racor fuel hose is fire resistant and meets SAE J157 Type A class and SAE J194 standards. This hose delivers test proven performance in a wide operating temperature range, constant working pressure in popular sizes, long-lasting reinforced construction, kink and Part Number Hose ID Working Pressure Burst Pressure Min. Bend Radius CGH-5 1/4 (6.3 mm) 500 PSI (3.5 MPa) 000 PSI (14 MPa) 1 (5 mm) CGH-6 5/16 (8 mm) 500 PSI (3.5 MPa) 000 PSI (14 MPa) 1 1/4 (30 mm) CGH-8 13/3 (10 mm) 500 PSI (3.5 MPa) 000 PSI (14 MPa) 1 3/4 (45 mm) Note: Additional sizes may be available - call Racor at (800) 344-386 Drain Valve Kit UL Listed drain valve kit is available part number RK 1949. cut resistance, and compatibility with a variety of standard fittings. Additional Features High-tensile steel wire braid. No-Skive - does not require the removal of outer cover to install. USCG-rated for gasoline, diesel, lube oil and hydraulic systems. Working temperature of -4 F to +1 F (-0 C to +100 C). Performance Information Test results are from controlled laboratory testing. Field results may vary. 1.0 8 0.75 6 PSI* 0.50 PSI* 4 0.5 0.0 0 30 45 60 0 10 0 30 40 50 60 70 Flow (GPH) SAE J905 Fuel Flow Restriction Grams Racor Gasoline Solid Capacity Test (using SOFTC-A; 10 micron Element) *PSI x.036 = inhg. (PSI x 6.895 = kpa)

660R-RAC-01 Replacement Parts Part No. Description 1. RK 1411 Mounting Head Kit 1. 0707 Gasket Kit 3. Replacement Elements S33 10 Micron 4. RK 44 Bowl O-ring Kit 5. RK 30475 Clear Bowl Kit 6. RK 30476 Self-venting Drain Kit 3 4 5 6

660R-RAC-0 Replacement Parts Part No. Description 1. RK 1411 Mounting Head Kit 1. 0707 Gasket Kit 3. Replacement Elements S33 UL 10 Micron (UL Marine) 4. RK 44 Bowl O-ring Kit 5. RK 30473-0 Metal Bowl Kit 6. 918-N6 Steel Port Plug 3 4 5 6

Limited Warranties Statement All products manufactured or distributed by Racor are subject to the following, and only the following, LIMITED EXPRESS WARRANTIES, and no others: For a period of one (1) year from and after the date of purchase of a new Racor product, Racor warrants and guarantees only to the original purchaser-user that such a product shall be free from defects of materials and workmanship in the manufacturing process. The warranty period for pumps and motors is specifically limited to ninety (90) days from date of purchase. A product claimed to be defective must be returned to the place of purchase. Racor, at its sole option, shall replace the defective product with a comparable new product or repair the defective product. This express warranty shall be inapplicable to any product not properly installed and properly used by the purchaser-user or to any product damaged or impaired by external forces. THIS IS THE EXTENT OF WARRANTIES AVAILABLE ON THIS PRODUCT. RACOR SHALL HAVE NO LIABILITY WHATSOEVER FOR CONSEQUENTIAL DAMAGES FLOWING FROM THE USE OF ANY DEFECTIVE PRODUCT OR BY REASON OF THE FAILURE OF ANY PRODUCT. RACOR SPECIFICALLY DISAVOWS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED INCLUDING, WITHOUT LIMITATION, ALL WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE (EXCEPT FOR THOSE WHICH APPLY TO PRODUCT OR PART THEREOF THAT IS USED OR BOUGHT FOR USE PRIMARILY FOR PERSONAL, FAMILY, OR HOUSEHOLD PURPOSES), WARRANTIES OF DESCRIPTION, WARRANTIES OF MERCHANTABILITY, TRADE USAGE OR WARRANTIES OR TRADE USAGE. Warning Failure or improper selection or improper use of the products and/or systems described herein or related items can cause death, personal injury and property damage. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the applications are met. The products described herein, including with limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. The following statement is required pursuant to proposition 65, applicable in the State of California: This product may contain a chemical known to the State of California to cause cancer or reproductive toxicity. 008 Parker Hannifin Corporation May 008