320R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev.

Similar documents
660R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev F

Product Features: Removes 99% of free water. Available with 2, 10, or 30 micron Aquabloc II media

120RMAM Marine Series Fuel Filter/Water Separators

75500MAX Series and 75500MAXM Series

Racor 75500FGX Turbine Series fuel

Marine Gasoline Products

400 Series Spin-on Fuel Filter/Water Separators

Product Features. Easy installation. Pump adds only 3.3 to the overall assembly height. 60 GPH (227 LPH) flow rate while in priming mode.

900MA/MAM and 1000MA/MAM (for marine applications)

Marine Fuel Filtration Marine 800 Series

Marine Fuel Filtration. Marine FBO. Features:

Marine Fuel Filtration. Marine Turbine Series. Stage One: Separation. Stage Two: Coalescing. Stage Three: Filtration. And more

General The Racor Marine Diesel Spin--on Series feature a variety of compact sizes to fit most installations and cramped engine compartments.

All Racor filter materials and seals are compatible with ultra-low sulphur diesel (ULSD) fuel and B2 to B20 Biodiesel. See Racor bulletin 7679.

Marine Turbine Series

Gasoline Fuel Filters. For Marine Applications

900FH and 1000FH Turbine Series Fuel Filter/Water Separators Installation, Operation, and Service Information

Introduction. Marine Turbine Series. Model Illustrations. Special Notes. Specifications 77/1000MA 73/1000MA 75/500MAX 75/900MAX 79/1000MAV 75/1000MAX

Section: B Marine Fuel Filtration

Maintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

DY Series 1-Piece Ball Valves. Catalog 1001C-A. July 2012 欧陆传动

Maintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC

High Pressure Gear Pumps & Motors Series PZG Pumps Series MZG Motors

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

GARDEN HOSE UTILITY PUMP

Models P, P, P, , DANGER

18324 INSTALLATION INSTRUCTIONS 65 PONTIAC LEMANS

Figure 1: HB Series Ball Valve Cross Sectional View DISASSEMBLY WARNING: MAKE CERTAIN THE SYSTEM IN WHICH THE VALVE IS INSTALLLED IS EXHAUSTED OF ALL

MARINE. Diesel Fuel/Water Separators. Installation. Operation. Parts. Service Information

PARTS AND INSTALLATION MANUAL

INSTRUCTION MANUAL G-Surge Tank #40007, #40008 & #40009

Viscount I Hydraulic Motor and Displacement Pump

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Gauge Adapter Instruction Manual

Pulse Width Modulation Valves. Models SPW-0 thru -7

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Operation and Maintenance Manual

Installation & Service Instructions

D Instructions/Parts. Siphon Feed Detail Spray Gun D

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

FUEL KITS P/N & 526-4

Flow Control Valves Check Valves Gauge Control Valves. Colorflow Valves

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

AEROMOTIVE Part # Mustang 5.0L Fuel System Kit INSTALLATION INSTRUCTIONS

Installation and Maintenance Manual

T1-Titanium Non-HVLP Spray Gun

Voltmaster Centrifugal Trash Pumps

STC 2L Series Solenoid Valves

SHOP PRO FXP 95 TECHNICAL MANUAL

# and # FAST Fuel System Kits

Sinclair Collins. Process Control Valves. For Steam, Hot and Cold Liquids -40 to 450 F up to 500 psi. Catalog SCV-100/USA April 2001

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

HP-100 Dual-Flo Petroleum Hand Pump

M39075 ( IF- 1) Integra- Fuse Rivet Tool

Manifold w/ Needle Valve Instruction Manual

SNAPP. The One-Piece, High-Performance Snap-In Fuel Filter Water Separator

Operating and Installation Instructions

Owner s Manual Supplement. Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.

STC 2W Series Solenoid Valves

SUBMERSIBLE SUMP PUMPS

FOR TECHNICAL ASSISTANCE

Fuel Pro Series Filter/Separator/Warmer Installation Instructions

WARNING User Responsibility

Dual Flow Manifold Systems Instruction Manual

BMK-30. Heavy-Duty By-Pass Filtration System Installation and Servicing Instructions

3V SERIES SOLENOID VALVE

AEROMOTIVE Part # Generic EFI Fuel System INSTALLATION INSTRUCTIONS

FPS-500. Fuel Polishing System Eliminates Microbial Contamination. Operating Manual

SHOP PRO FXP TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT TABLE OF CONTENTS

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

Snap-tite Quick Disconnect Couplings for Applications Requiring Virtually No Air Inclusion or Spillage

Operating instructions Form no safety definitions

SHOP PRO ST TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT TABLE OF CONTENTS

Rotary Plug Valves (PR Series) Catalog 4126-PR Revised, July 2003

Installation and Startup Manual Hydraulic Pumps Series VP1-095 /-110/ -130

SNAPP. The One-Piece, High-Performance Snap-In Fuel Filter Water Separator. Next

RECYCOIL Used Oil Tank

45 VALVE SERIES. 2-Position 4-Way 5-Ports, Installation & Service Instructions. Valve with Stem Operator, Installation & Service Instructions

Quick Coupling Products

FUEL KITS P/N & 526-2

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

AEROMOTIVE Part # & Generic Fuel System Kit INSTALLATION INSTRUCTIONS

Installation, Operating and Maintenance Manual

4V130P-430P SERIES AIR PILOT VALVE

11101, & INSTALLATION INSTRUCTIONS

18660, 18661, & Stealth Fuel Cell INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

G8 Portable Fuel Transfer Pump Owner s Manual

DAVCO SHOP PRO FXP FOR MX ENGINES WITH REGULATOR TECHNICAL MANUAL

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

SUBMERSIBLE SUMP PUMPS

PORTABLE TRASH PUMPS MTP200 MTP300 MTP400

Parker Hannifin Filtration Group Racor Division DUAL FBO OPERATION AND MAINTENANCE INSTRUCTIONS SPARE PARTS

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Models GP5132, GP5136, GP5142 & GP5145. Triplex Ceramic Plunger Pump Operating Instructions / Manual

FOR TECHNICAL ASSISTANCE

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Transcription:

30R-RAC Series Gasoline Fuel Filter/Water Separators Instruction Part Number 37 Rev. D Overview: Racor 30R-RAC series filters are designed for high-performance applications, which means your engine will perform better than ever with clean, water-free fuel. The spin-on filter is simple to replace and reuseable clear plastic (or metal) contaminant collection bowl features a self-venting drain (or metal plug) for removing unwanted muck and water. Contact Information: Parker Hannifin Corporation Racor Division P.O. Box 308 3400 Finch Road Modesto, CA 95353 phone 800 344 386 09 51 7860 fax 09 59 378 racor@parker.com www.parker.com/racor www.parker.com/racorproducts Product Features: 30R-RAC-0 is UL listed and USCG approved for inboard marine use High-capacity 10 micron Aquabloc II media 60 GPH (7 LPH) maximum flow rate Superior corrosion resistance with electrostatic powder coating 3-port die-cast aluminum mounting head with 1/4-18 NPTF threads Removes 99% of free water

Mounting Information Top View IN IN.0 in. (5.1 cm) OUT 3/8 (1.0 cm) diameter clearance for fasteners Installation Diagram Fuel tanks above filter head pressure should not exceed maximum PSI of filter. Fuel Tank (Pressure Side Installation) Optional Bypass Installation and Operation (allows user to service filter without shutting down engine.) Valves 1 3 Unit On-line Open Open Closed Unit Off-line Closed Closed Open Install a shut-off valve when fuel tank is higher than filter Optional fuel transfer pump not to exceed maximum PSI or flow rate of filter. Not ideal - pumps emulsify water hindering filter performance. Fuel Tank (Ideal Vacuum Side Installation) Valve 1 Valve Engine Install a check valve (with light or no restriction) when tank is lower than filter to main prime. Fuel transfer pump (IDEAL vacuum side installation) Fuel Tank (Vacuum Side Installation) Fuel tank below filter lift should not exceed 4 inhg. Valve 3 Maintain a service clearance below filter assembly of at least 1 in. (.5 cm)

Installation Guidelines Danger! Great care must be exercised to avoid potential fire hazards during installations on gasoline fuel systems. Do not smoke or permit open flames or sparks near the fuel system. 1. Any secondary or pressure side filters located between pump and engine should be serviced and left in place.. Mount unit vertically on suction side of fuel pump, transfer pump, or nonremovable filters, whichever comes first. 3. Ensure a suitable pipe thread sealing compound is used on NPT threads of fitting prior to installation into head. For mounting flexibility, there are two inlet ports and one outlet port. Plated steel fittings are recommended. Plug unused port with provided steel NPT plug - do not use tapes on NPT threads. 4. Use quality fuel hose in maximum fuel line size applicable to reduce potential fuel flow restrictions. Note: USCG accepted hose recommended. Contact your Racor distributor for your application requirements. Priming The Unit 1. Carefully spin off bowl/filter as one and fill both with clean fuel (use a strap wrench near top of element to remove and avoid damage).. Spin bowl/filter onto mounting head and tighten snugly by hand - do not use tools to tighten. 3. Start engine and check for leaks. If engine is difficult to start or runs rough, check that drain, bowl, filter, and port plug are securely tightened. Check all connections for security and hoses to ensure there are no kinks or sharp bends that would create excessive restriction. Service Danger! When servicing gasoline fuel systems, extreme care must be exercised to avoid potential fire hazards. Do not smoke or permit open flames near fuel system during servicing procedures. Draining the Collection Bowl Water is heavier than fuel and will settle at bottom of bowl and appear different in color. In extremely humid conditions, take a fuel sample (in clear container) frequently, daily, if needed and drain as required if water is present. 1. Place a suitable container below unit to collect contaminants.. Close fuel tank valve (if applicable), then open Racor self-venting drain (-01 model) or loosen/remove drain plug (-0 model) at bottom of bowl. Note: a UL listed drain valve kit is available for -0 models, order part no. RK 1949. 3. Prime fuel system following the manufacturer s procedure - refer to Priming The Unit. Filter Replacement Filter replacement frequency is determined by contamination levels in fuels. Fuel flow to engine becomes restricted as filter slowly plugs with contaminants, resulting in noticeable power loss and/ or hard starting. Replace filter annually, every 100 hours, or when there is a noticeable power loss, whichever comes first. Change filter as soon as possible. Note: always carry extra replacement filters as one tankful of excessively contaminated fuel can plug a filter. Clean any debris or dirt away from Racor head/filter joint prior to removal. 1. Place a suitable container below unit to collect contaminants.. Close valve at fuel tank (if applicable) open or remove drain (plug) to empty Racor filter of fuel. 3. Spin filter and bowl off together (use a strap wrench on filter), then remove bowl from filter. 4. Clean, bowl O-ring gland and sealing surface of mounting head, of dirt, debris, or gums. 5. Apply lube oil to new seal and bowl O-ring supplied with new filter. 6. Place new seal onto top of new filter and O-ring into bowl gland. 7. Spin bowl onto filter, then both onto head. Tighten snugly by hand do not use tools to tighten. 8. Prime fuel system following manufacturer s procedure - refer to Priming The Unit.

Troubleshooting Procedures A major cause of power loss or hard starting is result of an air leak (or clogged filter). If your unit will not prime or fails to hold prime, check that drain, bowl, and filter are properly tightened. Next, check all fitting connections and ensure fuel lines are not pinched or clogged with contaminants. If problems persist (and filter is new) call Racor Technical Service for assistance: (800) 344-386 or (09) 575-7555. Applies to all models Specifications 30R-RAC-01 30R-RAC-0 Application: Inboard Outboard Maximum Flow Rate 60 GPH (7 LPH) 60 GPH (7 LPH) Center Threads 1-14 1-14 Port Size 1/4-18 NPTF 1/4-18 NPTF Number of Ports: Inlets Outlets Height 9.3 in. (3.6 cm) 9.0 in. (.8 cm) Width 4.0 in. (10. cm) 4.0 in. (10. cm) Depth 4.0 in. (10.cm) 4.0 in. (10.cm) Weight (dry).0 lb (0.90 kg).0 lb (0.90 kg) Clean Pressure Drop 0.61 PSI (4.3 kpa) 0.61 PSI (4.3 kpa) Maximum Pressure 7 PSI (0.5 bar) 7 PSI (0.5 bar) Underbowl Clearance 1.0 in. (.5 cm) 1.0 in. (.5 cm) Water Removal Efficiency 99% 99% Ambient Temperature Range -40 to +55 F (-40 to +14 C) Maximum Fuel Temperature 190 F (3 C) No Yes 1 Yes Yes 1

Accessories Hose Racor fuel hose is fire resistant and meets SAE J157 Type A class and SAE J194 standards. This hose delivers test proven performance in a wide operating temperature range, constant working pressure in popular sizes, long-lasting reinforced construction, kink and Part Number Hose ID Working Pressure Burst Pressure Min. Bend Radius CGH-5 1/4 (6.3 mm) 500 PSI (3.5 MPa) 000 PSI (14 MPa) 1 (5 mm) CGH-6 5/16 (8 mm) 500 PSI (3.5 MPa) 000 PSI (14 MPa) 1 1/4 (30 mm) CGH-8 13/3 (10 mm) 500 PSI (3.5 MPa) 000 PSI (14 MPa) 1 3/4 (45 mm) Note: Additional sizes may be available - call Racor at 1.800.344.386 cut resistance, and compatibility with a variety of standard fittings. Additional Features High-tensile steel wire braid. No-Skive - does not require the removal of outer cover to install. USCG-rated for gasoline, diesel, lube oil and hydraulic systems. Working temperature of -4 F to +1 F (-0 C to +100 C). Drain Valve Kit UL Listed drain valve kit is available for -0 models. Part number RK 1949. RK 68 Bowl Wrench Hand wrench to removes all metal and clear spin-on bowls that feature external ribs. Performance Information Test results are from controlled laboratory testing. Field results may vary. 1.0 8 0.75 6 PSI* 0.50 PSI* 4 0.5 0.0 0 15 30 45 60 0 10 0 30 40 50 60 70 Flow (GPH) SAE J905 Fuel Flow Restriction Grams Racor Gasoline Solid Capacity Test (using SOFTC-A; 10 micron Element) *PSI x.036 = inhg. (PSI x 6.895 = kpa)

30R-RAC-01 Replacement Parts Part No. Description 1. RK 0180 Mounting Head Kit 1. 0707 Gasket Kit 3. S37 10 Micron Replacement Filter 4. RK 44 Bowl O-ring Kit 5. RK 30475 Clear Bowl Kit 6. RK 30476 Self-venting Drain Kit 3 4 5 6

30R-RAC-0 Replacement Parts Part No. Description 1. RK 0180 Mounting Head Kit 1. 0707 Gasket Kit 3. S38 UL 10 Micron Replacement Filter 4. RK 44 Bowl O-ring Kit 5. RK 30473-0 Metal Bowl Kit 6. 918-N6 Steel Port Plug 3 4 5 6

Limited Warranties Statement All products manufactured or distributed by Racor are subject to the following, and only the following, LIMITED EXPRESS WARRANTIES, and no others: For a period of one (1) year from and after the date of purchase of a new Racor product, Racor warrants and guarantees only to the original purchaser-user that such a product shall be free from defects of materials and workmanship in the manufacturing process. The warranty period for pumps and motors is specifically limited to ninety (90) days from date of purchase. A product claimed to be defective must be returned to the place of purchase. Racor, at its sole option, shall replace the defective product with a comparable new product or repair the defective product. This express warranty shall be inapplicable to any product not properly installed and properly used by the purchaser-user or to any product damaged or impaired by external forces. THIS IS THE EXTENT OF WARRANTIES AVAILABLE ON THIS PRODUCT. RACOR SHALL HAVE NO LIABILITY WHATSOEVER FOR CONSEQUENTIAL DAMAGES FLOWING FROM THE USE OF ANY DEFECTIVE PRODUCT OR BY REASON OF THE FAILURE OF ANY PRODUCT. RACOR SPECIFICALLY DISAVOWS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED INCLUDING, WITHOUT LIMITATION, ALL WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE (EXCEPT FOR THOSE WHICH APPLY TO PRODUCT OR PART THEREOF THAT IS USED OR BOUGHT FOR USE PRIMARILY FOR PERSONAL, FAMILY, OR HOUSEHOLD PURPOSES), WARRANTIES OF DESCRIPTION, WARRANTIES OF MERCHANTABILITY, TRADE USAGE OR WARRANTIES OR TRADE USAGE. Warning Failure or improper selection or improper use of the products and/or systems described herein or related items can cause death, personal injury and property damage. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the applications are met. The products described herein, including with limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. The following statement is required pursuant to proposition 65, applicable in the State of California: This product may contain a chemical known to the State of California to cause cancer or reproductive toxicity. 008 Parker Hannifin Corporation May 008