GQA DC-DC Power Module Series

Similar documents
HQA DC-DC Power Module Series

HQA DC-DC Power Module Series

Advance Data Sheet: i3a Series 1/32 nd brick Power Module. I3A Series DC/DC Power Modules 9-53V Input, 8A Output 100W 1/32nd Brick Power Module

Advance Data Sheet: Metamere iba Series Non-isolated SMT Power Module PicoBrick

Advance Data Sheet: i6a Series 1/16 th brick Power Module. I6A Series DC/DC Power Modules 9-53V Input, 20A Output 250W 1/16 th Brick Power Module

Datasheet DC-DC Power Modules Xeta ihg Half Brick 48V Input, 12V/25A Output

Advance Data Sheet: Metamere iac Series Non-isolated SMT Power Module

Data Sheet: Asceta TM iql Series Single Output Quarter Brick. Asceta iql Series DC/DC Power Modules 48V Input, 12V / 25A /300W Output Quarter Brick

Data Sheet: Supereta TM iqn Series Single Output Quarter Brick. Supereta iqn Series DC/DC Power Modules 48V Input, 28V / 7A Output Quarter Brick

Data Sheet: Asceta TM iql Series Single Output Quarter Brick. Asceta iql Series DC/DC Power Modules 48V Input, 12V / 25A /300W Output Quarter Brick

Advance Data Sheet: idq Series Filter Module. idq Series Filter Module 75V Input, 10A Output

Output Current. Output Unit. Feature Set i 6A A 033 V R TDK- Lambda Dallas Technical Center. 14 Amps 3.3V Single

S24SP15004 series 60W Single Output DC/DC Converter

S24SP series 40W Single Output DC/DC Converter

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

DH50 SERIES. DATASHEET Rev. A

2W, Low Cost DIP, Dual Output DC/DC Converters

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Delphi NC30 Series Non-Isolated Point of Load DC/DC Power Modules: 12Vin, 0.9V-5Vout, 30A

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

QHW050F1, QHW075F1, and QHW100F1 Power Modules: dc-dc Converters; 36 to 75 Vdc Input, 3.3 Vdc Output; 33 W to 66 W

(typ.) (Range) ±18 330# 89 MPW MPW

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

Delphi Series V48SH, 1/16 th Brick 100W DC/DC Power Modules: 48V in, 1.8V, 30A out

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

PG02S Series 2W DC/DC CONVERTER, SIP-Package

Delphi D12S Non-Isolated Point of Load

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

(typ.) (Range) Load

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Delphi Series V48SC, 1/16th Brick 120W DC/DC Power Modules: 48V in, 12V, 10A out

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

EB Series Eighth - Brick Up to 100 Watt DC-DC Converter

HBC DC-DC Series Data Sheet 300-Watt Half-Brick Converters

APPLICATIONS: AVAILABLE OPTIONS

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

North America Asia-Pacific Europe, Middle East

Delphi Series IPM, Non-Isolated, Integrated

NES50-48 : High efficient DC/DC converters

ISOLATED DC-DC Converter EC2SB SERIES APPLICATION NOTE

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

Features. Applications

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction

Asia-Pacific Europe, Middle East North America Bel Power Solutions, Inc. BCD.

SH01S/D Series 1W DC/DC CONVERTER, SMD-Package

SQ24 Series DC-DC Converter Data Sheet VDC Input; Standard Outputs from 1-12 VDC

Delphi NE Series Non-Isolated Point of Load DC/DC Modules: 3.1~13.8Vin, 0.59V-5.1Vout, 6Aout

YM12S05 DC-DC Converter Data Sheet Vdc Input; Vdc 5A

FW250R1 and FW300R1 Power Modules: dc-dc Converters: 36 Vdc to 75 Vdc Input, 28 Vdc Output; 250 W to 300 W

VP ELECTRONIQUE MASSY CEDEX

PL10S-12 Non Isolated DC/DC Converters Long Form Datasheet

MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options

OSR03-24 S 05 A Series Name Input Output Output Assembly Voltage Quantity Voltage Option PART NUMBER STRUCTURE

NXJ1 Series Isolated 1W Single Output SM DC-DC Converters

HAE S 05 - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current

IND065BLV Hornet: Non-Isolated DC-DC Voltage Regulator Modules

MTU1 Series Isolated 1W Single & Dual Output SM DC/DC Converters

Delphi NE Series Non-Isolated Point of Load

NCS12 Series Isolated 12W 4:1 Input Single & Dual Output DC/DC Converters

HAE S 05 W - P HS Series Name Input Output Output Input Ctrl and Assembly Option Voltage Quantity Voltage Range Pin Options

DORADO MV DC/DC CONVERTERS 24V Input 12VDC 8A Output

NXE1 Series Isolated 1W Single Output SM DC/DC Converters

CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters

HAE S 05 W - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

MEE1 Series Isolated 1W Single Output DC/DC Converters

1000 WATT 24S12.84FXM DC/DC CONVERTER

Output Current Input Current Over Voltage. VDC VDC ma ma(typ.) ma(typ.) VDC μf % MKZI10-24S

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Order Code. Voltage range. Reflected ripple current. Isolation test voltage

Maximum Input Current Vin=18V, 100% Load A Vin=24V ma No-Load Input Current

NXJ2 Series Isolated 2W Single Output SM DC-DC Converters

Sixteenth brick format 4:1 input voltage range 2.25kV basic isolation Remote ON/OFF and trim pins UVLO, OTP, OVP, OCP and SCP Efficiency up to 91%

B70SR12424A/B/C/D 12V Output DC/DC Converter, Box Type Package

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Input Voltage Continuous 0 80 VDC. Operating Ambient Temperature C Storage Temperature C. Operating Input Voltage Range VDC

Volant NEA/NEF010 Series

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current

DVFL2800S Series HIGH RELIABILITY HYBRID DC-DC CONVERTERS DESCRIPTION FEATURES

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 150 WATT RAILWAY APPLICATIONS HWB150 SERIES

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

B70SR24125A/B/C/D 24V Output DC/DC Converter, Box Type Package

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

NDS6 Series Isolated 6W Wide Input Single & Dual Output DC/DC Converters

RCD15W Series PART NUMBER STRUCTURE

PARAMETER NOTES MIN TYP MAX UNITS. Input Voltage Continuous 0 40 VDC. Operating Ambient Temperature C. Storage Temperature C

NXE1 Series Isolated 1W Single Output SM DC-DC Converters

Efficiency Model dependant 86 ~ 88% Isolation. Isolation Cap. Switching Freq. Safety. Case Material Base Material Potting.

NOT RECOMMENDED FOR NEW DESIGNS

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Reflected ripple current. Case Temperature rise above ambient ABSOLUTE MAXIMUM RATINGS

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

Transcription:

GQA DC-DC Power Module Series 9-36V Wide Input, 1W Output Quarter Brick The GQA Series of dc-dc converters offers a high performance quarter brick package with true usable power, a wide range input voltage operation range, and a broad selection of operating output voltages. A robust package design with multiple baseplate options make GQA modules suitable for use in a wide variety of demanding environments. Features Size 6.6mm x 49.5 mm x 1.7 mm (.39 in. x 1.95 in. x.5 in.) flanged base plate Through hole pins 4.57mm tail length Up to 1W of output power Negative logic on/off Low output noise Output voltage adjustment Constant switching frequency Remote Sense (selected models) Full, auto-recovery protection: o Input under voltage o Output Over current o Short circuit o Over Temperature ISO Certified manufacturing facilities Options Size - 6.6mm x 39.5 mm x 1.7 mm (.39 in. x 1.56 in. x.5 in.) nonflanged base plate Clock Synchronization Case and Potting for additional protection against environment 3KVdc input to output isolation 1/37

Ordering information: Product Identifier Package Size Platform Input Voltage Output Current/ Power Output Units Main Output Voltage # of Outputs Feature Set Indicator G Q A W 4 A 8 V - 7 - R G-series Quarter brick A series W - 9-36V 4 18-36 5-5 1-1 A Amps W Watts 48-48 8 8 4 4 15-15 1 1 5 5 V Single 7 Standard Screening Indicator R-RoHS 6 Option Table: Feature Set Negative Logic On/Off.18 Pin Length Flanged Base Plate Non- Flanged Base Plate Case & Potting 3KV isolation Case & Potting 7 X X X N7 X X X P7 X X X X NP7 X X X X Product Offering: Code Vin Vout Iout (A) Maximum Output Power (W) Remote Sense GQA43A48V-7-R 18-36 48.5 1 No GQAW4A8V-7-R 9-36 8 4.8 1 No GQAW5A4V-7-R 9-36 4 5 1 No GQAW8A15V-7-R 9-36 15 8 1 Yes GQAW1A1V-7-R 9-36 1 1 1 Yes GQAW4A5V-7-R 9-36 5 4 1 Yes 41 Mile Cars Way, Suite 15 National City, CA 9195 Phone (8)56-34 Toll Free Lambda.TechSupport@us.tdk-lambda.com www.us.tdk-lambda.com/lp/ /37

Mechanical Specification: (with flange) Dimensions are in mm [in]. Unless otherwise specified tolerances are: x.x [x.xx] ±.5 [.], x.xx [x.xxx] ±.5 [.1] 3/37

Mechanical Specification: (no flange) Dimensions are in mm [in]. Unless otherwise specified tolerances are: x.x [x.xx] ±.5 [.], x.xx [x.xxx] ±.5 [.1] To avoid damaging components, do not exceed 3.mm [.1 ] depth for M3 screws 4/37

Mechanical Specification: (with flange - potted) Dimensions are in mm [in]. Unless otherwise specified tolerances are: x.x [x.xx] ±.5 [.], x.xx [x.xxx] ±.5 [.1] 5/37

Mechanical Specification: (no flange - potted) Dimensions are in mm [in]. Unless otherwise specified tolerances are: x.x [x.xx] ±.5 [.], x.xx [x.xxx] ±.5 [.1] To avoid damaging components, do not exceed 3.mm [.1 ] depth for M3 screws 6/37

Recommended Hole Pattern: (top view with flange) (without flange) Pin Assignment: PIN FUNCTION PIN FUNCTION 1 Vin(+) 5 sense (-), select models On/Off 6 Trim 3 Vin(-) 7 sense (+), select models 4 Vo(-) 8 Vo(+) Pin base material is tellurium copper with tin over nickel plating; the maximum module weight is 85g (3oz) 7/37

Absolute Maximum Ratings: Stress in excess of Absolute Maximum Ratings may cause permanent damage to the device. Characteristic Min Max Unit Notes & Conditions Continuous Input Voltage -.5 4 Vdc Transient Input Voltage 5 Vdc (t < 1s) Isolation Voltage *Engineering estimate Input Characteristics: Unless otherwise specified, specifications apply over all Rated Input Voltage, Resistive Load, and Temperature conditions. Characteristic Min Typ Max Unit Notes & Conditions Operating Input Voltage 1 36 Vdc All except 48Vout Operating Input Voltage (48Vout) 18.5 36 Vdc Maximum Input Current 17 A Vin = to Vin,max; all except 48Vout Maximum Input Current (48Vout) 1 A Vin = to Vin,max Turn-on Voltage 9.5 1.5 Vdc All except 48Vout Turn-on Voltage (48Vout) 17 18 Vdc Turn-off Voltage 8.5 9 Vdc All except 48Vout Turn-off Voltage (48Vout) 15.5 17.5 Vdc Hysteresis 1 Vdc Startup Delay Time from application of input voltage 5 ms Vo = to.1*vo,nom; on/off =on, Io=Io,max, Tc=5 C Startup Delay Time from on/off 5 ms Vo = to.1*vo,nom; Vin = Vi,nom, Io=Io,max,Tc=5 C Output Voltage Rise Time ms Io=Io,max,Tc=5 C, Vo=.1 to.9*vo,nom Inrush Transient.3 A s Input Reflected Ripple 15* mapp See input/output ripple and noise measurements figure; BW = MHz Input Ripple Rejection 55* db @1Hz *Engineering estimate 15 Vdc Input to Output Storage Temperature -55 15 C Operating Temperature Range (Tc) 5 Vdc Input to Output (-NP7) 3 Vdc Input to Output (-P7) option 15 Vdc Baseplate to Input or Output 5 Vdc Baseplate to Input or Output (-P7, -NP7) -4 15* C Measured at the location specified in the thermal measurement figure. Maximum temperature varies with model number, output current, and module orientation see curve in thermal performance section of the data sheet. Caution: The power modules are not internally fused. An external input line normal blow fuse with a maximum value of 3A is required, see the Safety Considerations section of the data sheet. 8/37

GQA4A48V: 48V,.5A Output Characteristic Min Typ Max Unit Notes & Conditions Output Voltage Initial Setpoint 46.6 48 49.5 Vdc Vin=Vin,nom; Io=Io,max; Tc = 5 C Output Voltage Tolerance 46.1 48 49.9 Vdc Over all rated input voltage, load, and temperature conditions to end of life Efficiency 91.5 % Vin=Vin,nom; Io=Io,max; Tc = 5 C Line Regulation.5 % Vin=Vin,min to Vin,max Load Regulation.3 % Io=Io,min to Io,max Temperature Regulation.5 % Tc=Tc,min to Tc,max Output Current.5 A Output Current Limiting Threshold 4 A Vo =.9*Vo,nom, Tc<Tc,max Short Circuit Current.1 A Vo =.5V, Tc = 5 C Output Ripple and Noise Voltage 15 3* mvpp 35 mvrms Measured across one uf and one.1uf ceramic capacitor see input/output ripple measurement figure; BW = MHz Output Voltage Adjustment Range 95 11 %Vo,nom Adjustment range is reduced at input voltages below V Dynamic Response: Recovery Time Transient Voltage 1 3 ms mv di/dt =.1A/uS, Vin=Vin,nom; load step from 5% to 75% of Io,max Output Voltage Overshoot during startup 5 % Vin=Vin,nom; Io=Io,max,Tc=5 C Switching Frequency 7 khz Fixed Output Over Voltage Protection 54 V External Load Capacitance 1& uf Isolation Capacitance.1 uf Isolation Resistance 1 MΩ Ra 61.9 kω Required for trim calculation Rb 6.19 kω Required for trim calculation * Engineering estimate & Contact TDK-Lambda for applications that require additional capacitance or very low esr 9/37

Electrical Characteristics: GQA43A48V: 48V,.5A Output Efficiency, h(%) 94 9 9 88 86 84 8 8.1.34.58.8 1.6 1.3 1.54 1.78..6.5 Vin = 18V Vin = 8V GQA43A48V Typical Efficiency vs. Input Voltage at Ta=5 degrees. Power Dissipation (W) 16 14 1 1 8 6 4.1.34.58.8 1.6 1.3 1.54 1.78..6.5 Vin = 18V Vin = 8V Vin = 4V GQA43A48V Typical Power Dissipation vs. Input Voltage at Ta=5 degrees Input Current (A) 9 8 7 6 5 4 3 1 14 16. 18.4.6.8 5 7. 9.4 31.6 33.8 36 Input Voltage (V) Io_min =.1A Series Io_max =.5A GQA43A48V Typical startup characteristic from on/off at full load. Blue trace - on/off signal, red trace output voltage GQA43A48V Typical Input Current vs. Input Voltage Characteristics GQA43A48V Typical startup characteristic from input voltage application at full load. Red trace - output voltage, blue trace input voltage GQA43A48V Typical transient response. Output voltage response to load step from 5% to 75% of full load with output current slew rate of.1a/us. 1/37

Electrical Characteristics (continued): GQA43A48V: 48V,.5A Output 5 Output Voltage (V) 48 46 44 4 4 38.1 1.1.1 3.1 4.1 5.1 Vin = 18V Vin = 8V Vin = 3V GQA43A48V Typical Output Current Limit Characteristics vs. Input Voltage at Ta=5 degrees. Output Voltage (V) 49 48.8 48.6 48.4 48. 48 47.8 47.6 47.4 47. 47.1.34.58.8 1.6 1.3 1.54 1.78..6.5 GQA43A48V Typical Output Ripple at nominal Input voltage and full load at Ta=5 degree % Change of Vout Trim Down Resistor % Change of Vout Trim Up Resistor -5% 1154K +5% 9.3K e.g. trim up 5% Rup :=.6 61.9 5.4 48 6.19 1 +1% 1.55K Vin = 4V GQA43A48V Typical Load Regulation Characteristics at Ta=5 degrees. GQA43A48V Calculated resistor values for output voltage adjustment Intentionally blank 11/37

Thermal Performance: GQA43A48V: 48V,.5A Output 3.5 1.5 1.5 5 35 45 55 65 75 85 95 15 115 Temperature ( C) GQA43A48V maximum output current vs. baseplate temperature GQA43A48V thermal measurement location top view 3.5 1.5 1.5 NC.5 m/s (1 LFM) 1. m/s ( LFM) 1.5 m/s (3 LFM). m/s (4 LFM) TC, Thermal Limits 5 35 45 55 65 75 85 95 15 115 Temperature ( C) GQA43A48V maximum output current vs. ambient temperature at 8V input for airflow rates natural convection (6lfm) to 4lfm with airflow from pin 3 to pin 1 GQA43A48V typical temperature derating versus input voltage output with 1m/s ( lfm) airflow from pin 3 to pin 1. The thermal curves provided are based upon measurements made in TDK Lambda s experimental test setup that is described in the Thermal Management section. Due to the large number of variables in system design, TDK Lambda recommends that the user verify the module s thermal performance in the end application. The critical component should be thermo-coupled and monitored, and should not exceed the temperature limit specified in the derating curve above. It is critical that the thermocouple be mounted in a manner that gives direct thermal contact or significant measurement errors may result. TDK Lambda can provide modules with a thermocouple pre-mounted to the critical component for system verification tests. 1/37

Electrical Data: GQAW4A8V: 8V, 4.A Output Characteristic Min Typ Max Unit Notes & Conditions Output Voltage Initial Setpoint 7.16 8 8.84 Vdc Vin=Vin,nom; Io=Io,max; Tc = 5 C Output Voltage Tolerance 6.88 8 9.1 Vdc Over all rated input voltage, load, and temperature conditions to end of life Efficiency 89 % Vin=Vin,nom; Io=Io,max; Tc = 5 C Line Regulation.5 % Vin=Vin,min to Vin,max Load Regulation.3 % Io=Io,min to Io,max Temperature Regulation.5 % Tc=Tc,min to Tc,max Output Current 4. A Output Current Limiting Threshold 5.1 A Vo =.9*Vo,nom, Tc<Tc,max Short Circuit Current.1 A Vo =.5V, Tc = 5 C Output Ripple and Noise Voltage 1 5* mvpp 35 mvrms Measured across one uf and one.1uf ceramic capacitor see input/output ripple measurement figure; BW = MHz Output Voltage Adjustment Range 9 11 %Vo,nom Adjustment range is reduced at input voltages below 1V Dynamic Response: Recovery Time Transient Voltage 1 4 ms mv di/dt =.1A/uS, Vin=Vin,nom; load step from 5% to 75% of Io,max Output Voltage Overshoot during startup 5 % Vin=Vin,nom; Io=Io,max,Tc=5 C Switching Frequency 7 khz Fixed Output Over Voltage Protection 35 V External Load Capacitance 1& uf Isolation Capacitance.1 uf Isolation Resistance 1 MΩ Ra 36.5 kω Required for trim calculation Rb 3.1 kω Required for trim calculation * Engineering estimate & Contact TDK-Lambda for applications that require additional capacitance or very low esr 13/37

Electrical Characteristics: GQAW4A8V: 8V, 4.A Output Efficiency, η(%) 94 9 9 88 86 84 8 8.1.51.9 1.33 1.74.15.56.97 3.38 3.79 4. Vin = 1V Vin = 8V Vin = 3V Vin = 4V Power Dissipation (W) 18 16 14 1 1 8 6 4.1.51.9 1.33 1.74.15.56.97 3.38 3.79 4. Vin = 1V Vin = 8V Vin = 3V Vin = 4V GQAW4A8V Typical Efficiency vs. Input Voltage at Ta=5 degrees. GQAW4A8V Typical Power Dissipation vs. Input Voltage at Ta=5 degrees 14 Input Current (A) 1 1 8 6 4 8 1 16 4 8 3 36 Input Voltage (V) Io_min =.1A Io_mid =.1A Io_max = 4.A GQAW4A8V Typical startup characteristic from on/off at full load. Blue trace - on/off signal, red trace output voltage GQAW4A8V Typical Input Current vs. Input Voltage Characteristics GQAW4A8V Typical startup characteristic from input voltage application at full load. Red trace - output voltage, blue trace input voltage GQAW4A8V Typical transient response. Output voltage response to load step from 5% to 75% of full load with output current slew rate of.1a/us. 14/37

Electrical Characteristics (continued): GQAW4A8V: 8V, 4.A Output Output Voltage (V) 8.5 8 7.5 7 6.5 6 5.5 5 4.5 4.1.1 4.1 6.1 8.1 Vin = 1V Vin = 4V Vin = 3V GQAW4A8V Typical Output Current Limit Characteristics vs. Input Voltage at Ta=5 degrees. GQAW4A8V Typical Output Ripple at nominal Input voltage and full load at Ta=5 degree Output Voltage (V) 8. 8.15 8.1 8.5 8 7.95 7.9 7.85 7.8.1.9 1.74.56 3.38 4. Vin = 1V Vin = 4V Vin = 3V % Change of Vout Trim Down Resistor % Change of Vout Trim Up Resistor -5% 675K +5% 1.6K -1% 317.6K +1% 4.8K e.g. trim up 5% Rup :=.6 36.5 9.4 8 3.1 1 GQAW4A8V Typical Load Regulation Characteristics at Ta=5 degrees. GQAW4A8V Calculated resistor values for output voltage adjustment Intentionally blank 15/37

Thermal Performance: GQAW4A8V-7: 8V, 4.8A Output 4.5 4 3.5 3.5 1.5 1.5 5 45 65 85 15 15 Temperature ( C) GQAW4A8V maximum output current vs. baseplate temperature GQAW4A8V-7 thermal measurement location top view 4.5 4 3.5 3.5 1.5 1.5 NC.5 m/s (1 LFM) 1. m/s ( LFM). m/s (4 LFM) TC, Thermal Limits 5 45 65 85 15 15 Temperature ( C) GQAW4A8V maximum output current vs. ambient temperature at 8V input for airflow rates natural convection (6lfm) to 4lfm with airflow from pin 3 to pin 1 GQAW4A8V typical temperature derating versus input voltage output with 1m/s ( lfm) airflow from pin 3 to pin 1. The thermal curves provided are based upon measurements made in TDK Lambda s experimental test setup that is described in the Thermal Management section. Due to the large number of variables in system design, TDK Lambda recommends that the user verify the module s thermal performance in the end application. The critical component should be thermo-coupled and monitored, and should not exceed the temperature limit specified in the derating curve above. It is critical that the thermocouple be mounted in a manner that gives direct thermal contact or significant measurement errors may result. TDK Lambda can provide modules with a thermocouple pre-mounted to the critical component for system verification tests. 16/37

GQAW5A4V: 4V, 5A Output Characteristic Min Typ Max Unit Notes & Conditions Output Voltage Initial Setpoint 3.8 4 4.7 Vdc Vin=Vin,nom; Io=Io,max; Tc = 5 C Output Voltage Tolerance 3.4 4 4.96 Vdc Over all rated input voltage, load, and temperature conditions to end of life Efficiency 87 % Vin=Vin,nom; Io=Io,max; Tc = 5 C Line Regulation.5 % Vin=Vin,min to Vin,max Load Regulation.3 % Io=Io,min to Io,max Temperature Regulation.5 % Tc=Tc,min to Tc,max Output Current 5 A Output Current Limiting Threshold 6. A Vo =.9*Vo,nom, Tc<Tc,max Short Circuit Current.1 A Vo =.5V, Tc = 5 C Output Ripple and Noise Voltage 1 5* mvpp 35 mvrms Measured across one uf and one.1uf ceramic capacitor see input/output ripple measurement figure; BW = MHz Output Voltage Adjustment Range 9 11 %Vo,nom Adjustment range is reduced at input voltages below 1V Dynamic Response: Recovery Time Transient Voltage 1 4 ms mv di/dt =.1A/uS, Vin=Vin,nom; load step from 5% to 75% of Io,max Output Voltage Overshoot during startup 5 % Vin=Vin,nom; Io=Io,max,Tc=5 C Switching Frequency 7 khz Fixed Output Over Voltage Protection 3 V External Load Capacitance 1& uf Isolation Capacitance.1 uf Isolation Resistance 1 MΩ Ra 36.5 kω Required for trim calculation Rb 3.1 kω Required for trim calculation * Engineering estimate & Contact TDK-Lambda for applications that require additional capacitance or very low esr 17/37

Electrical Characteristics: GQAW5A4V: 4V, 5A Output 95 5 Efficiency, η(%) 9 85 8 75 7.1.59 1.8 1.57.6.55 3.4 3.53 4. 4.51 5 Vin = 1V Vin = 8V Vin = 3V Vin = 4V Power Dissipation (W) 15 1 5.1.59 1.8 1.57.6.55 3.4 3.53 4. 4.51 5 Vin = 1V Vin = 8V Vin = 3V Vin = 4V GQAW5A4V Typical Efficiency vs. Input Voltage at Ta=5 degrees. GQAW5A4V Typical Power Dissipation vs. Input Voltage at Ta=5 degrees Input Current (A) 15 1 5 6 11 16 1 6 31 36 Input Voltage (V) Io_min =.1A Io_mid =.5A Io_max = 5A GQAW5A4V Typical startup characteristic from on/off at full load. Blue trace - on/off signal, red trace output voltage GQAW5A4V Typical Input Current vs. Input Voltage Characteristics GQAW5A4V Typical startup characteristic from input voltage application at full load. Red trace - output voltage, blue trace input voltage GQAW5A4V Typical transient response. Output voltage response to load step from 5% to 75% of full load with output current slew rate of.1a/us. 18/37

Electrical Characteristics (continued): GQAW5A4V: 4V, 5A Output 4.5 4 Output Voltage (V) 3.5 3.5 1.5 1.1 1.1.1 3.1 4.1 5.1 6.1 7.1 8.1 Vin = 1V Vin = 3V Vin = 4V GQAW5A4V Typical Output Current Limit Characteristics vs. Input Voltage at Ta=5 degrees. GQAW5A4V Typical Output Ripple at nominal Input voltage and full load at Ta=5 degree % Change of Vout Trim Down Resistor % Change of Vout Trim Up Resistor -5% 675K +5% 1.6K -1% 317.6K +1% 4.8K e.g. trim up 5% Rup :=.6 36.5 9.4 8 3.1 1 GQAW5A4V Typical Load Regulation Characteristics at Ta=5 degrees. GQAW4A8V Calculated resistor values for output voltage adjustment Intentionally blank 19/37

Thermal Performance: GQAW5A4V: 4V, 5A Output 6 5 4 3 1 5 35 45 55 65 75 85 95 15 115 Temperature ( C) GQAW5A4V maximum output current vs. baseplate temperature at nominal line GQAW5A4V-7 thermal measurement location top view 5 4 3 1 NC.5 m/s (1 LFM) 1. m/s ( LFM). m/s (4 LFM) 3. m/s (6 LFM) TC Limits 4 6 8 1 1 Temperature ( C) GQAW5A4V maximum output current vs. ambient temperature at 8V input for airflow rates natural convection (6lfm) to 6lfm with airflow from pin 3 to pin 1 GQAW5A4V typical temperature derating versus input voltage output with m/s (4 lfm) airflow from pin 3 to pin 1. The thermal curves provided are based upon measurements made in TDK Lambda s experimental test setup that is described in the Thermal Management section. Due to the large number of variables in system design, TDK Lambda recommends that the user verify the module s thermal performance in the end application. The critical component should be thermo-coupled and monitored, and should not exceed the temperature limit specified in the derating curve above. It is critical that the thermocouple be mounted in a manner that gives direct thermal contact or significant measurement errors may result. TDK Lambda can provide modules with a thermocouple pre-mounted to the critical component for system verification tests. /37

Electrical Data: GQAW8A15V: 15V, 8A Output Characteristic Min Typ Max Unit Notes & Conditions Output Voltage Initial Setpoint 14.55 15 15.45 Vdc Vin=Vin,nom; Io=Io,max; Tc = 5 C Output Voltage Tolerance 14.4 15 15.6 Vdc Over all rated input voltage, load, and temperature conditions to end of life Efficiency 89 % Vin=Vin,nom; Io=Io,max; Tc = 5 C Line Regulation.5 % Vin=Vin,min to Vin,max Load Regulation.3 % Io=Io,min to Io,max Temperature Regulation.5 % Tc=Tc,min to Tc,max Output Current 8 A At loads less than Io,min the module will continue to regulate the output voltage, but the output ripple may increase Output Current Limiting Threshold 1 A Vo =.9*Vo,nom, Tc<Tc,max Short Circuit Current.1 A Vo =.5V, Tc = 5 C Output Ripple and Noise Voltage 8 * mvpp 1 mvrms Measured across one uf and one.1uf ceramic capacitor see input/output ripple measurement figure; BW = MHz Output Voltage Adjustment Range 9 11 %Vo,nom Adjustment range is reduced at input Output Voltage Sense Range 1 %Vo,nom voltages below 1V Dynamic Response: Recovery Time Transient Voltage.6 35* ms mv di/dt =.1A/uS, Vin=Vin,nom; load step from 5% to 75% of Io,max Output Voltage Overshoot during startup 5 % Vin=Vin,nom; Io=Io,max,Tc=5 C Switching Frequency 7 khz Fixed Output Over Voltage Protection 18 V External Load Capacitance 15& uf Isolation Capacitance.1 uf Isolation Resistance 1 MΩ Ra 36.5 KΩ Required for trim calculation Rb 1 KΩ Required for trim calculation * Engineering estimate & Contact TDK-Lambda for applications that require additional capacitance or very low esr 1/37

Electrical Characteristics: GQAW8A15V: 15V, 8A Output Efficiency, h(%) 96 94 9 9 88 86 84 8 8 1 3 4 5 6 7 8 Vin = 1V Vin = 8V Vin = 4V Power Dissipation (W) 16 9 1 3 4 5 6 7 8 Vin = 1V Vin = 8V Vin = 4V Vin = 4V GQAW8A15V Typical Efficiency vs. Input Voltage at Ta=5 degrees. GQAW8A15V Typical Power Dissipation vs. Input Voltage at Ta=5 degrees Input Current (A) 15 1 5 8 1 16 4 8 3 36 Input Voltage (V) Io_min =.1A Io_mid = 4A Io_max = 8A GQAW8A15V Typical startup characteristic from on/off at full load. Lower trace - on/off signal, upper trace output voltage GQAW8A15V Typical Input Current vs. Input Voltage Characteristics GQAW8A15V Typical startup characteristic from input voltage application at full load. Red trace - output voltage, Blue trace input voltage GQAW8A15V Typical output voltage response to load step from 5% to 75% of full load with output current slew rate of.1a/us and Cext = 1uF /37

Electrical Characteristics (continued): GQAW8A15V: 15V, 8A Output Output Voltage (V) 16 15 14 13 1 11 1 9 8 8 9 1 11 1 13 14 15 16 Vin = 1V Vin = 8V Vin = 4V GQAW8A15V Typical Output Current Limit Characteristics vs. Input Voltage at Ta=5 degrees. Output Voltage (V) 15.1 15.5 15 14.95 14.9 1 3 4 5 6 7 8 GQAW8A15V Typical Output Ripple at nominal Input voltage and full load at Ta=5 degree % Change of Vout Trim Down Resistor % Change of Vout Trim Up Resistor -5% 654K +5% 19.K -1% 34K +1% 4.6K e.g. trim up 5% Rup :=.6 36.5 15.75 15 1 1 Vin = 4V GQAW8A15V Typical Load Regulation Characteristics at Ta=5 degrees. GQAW8A15V Calculated resistor values for output voltage adjustment Intentionally blank 3/37

Thermal Performance: GQAW8A15V: 15V, 8A Output 8 6 4 NC.5 m/s (1 LFM) 1. m/s ( LFM) 1.5 m/s (3 LFM). m/s (4 LFM) TC Limits 5 35 45 55 65 75 85 95 15 115 Temperature ( C) GQAW8A15V maximum output current vs. ambient temperature at 8V input for airflow rates natural convection (6lfm) to 4lfm with airflow from pin 3 to pin 1 GQAW8A15V thermal measurement location top view 1.4 9 8 Derating Factor 1. 1..8.6 1 1 14 16 18 4 6 8 3 3 34 36 Line Voltage (V) 7 6 5 4 3 1 5 35 45 55 65 75 85 95 15 115 15 Temperature ( C) GQAW8A15V typical temperature derating versus input voltage output with 1m/s ( lfm) airflow from pin 3 to pin 1. GQAW8A15V maximum output current vs. baseplate temperature at nominal line The thermal curves provided are based upon measurements made in TDK Lambda s experimental test setup that is described in the Thermal Management section. Due to the large number of variables in system design, TDK Lambda recommends that the user verify the module s thermal performance in the end application. The critical component should be thermo coupled and monitored, and should not exceed the temperature limit specified in the derating curve above. It is critical that the thermocouple be mounted in a manner that gives direct thermal contact or significant measurement errors may result. TDK Lambda can provide modules with a thermocouple pre-mounted to the critical component for system verification tests. 4/37

Electrical Data: GQAW1A1V: 1V, 1A Output Characteristic Min Typ Max Unit Notes & Conditions Output Voltage Initial Setpoint 11.64 1 1.36 Vdc Vin=Vin,nom; Io=Io,max; Tc = 5 C Output Voltage Tolerance 11.54 1 1.48 Vdc Over all rated input voltage, load, and temperature conditions to end of life Efficiency 89 % Vin=Vin,nom; Io=Io,max; Tc = 5 C Line Regulation.5 % Vin=Vin,min to Vin,max Load Regulation.3 % Io=Io,min to Io,max Temperature Regulation.5 % Tc=Tc,min to Tc,max Output Current 1 A At loads less than Io,min the module will continue to regulate the output voltage, but the output ripple may increase Output Current Limiting Threshold 14.5 A Vo =.9*Vo,nom, Tc<Tc,max Short Circuit Current.1 A Vo =.5V, Tc = 5 C Output Ripple and Noise Voltage 4 18* mvpp 1 mvrms Measured across one uf and one.1uf ceramic capacitor see input/output ripple measurement figure; BW = MHz Output Voltage Adjustment Range 9 11 %Vo,nom Adjustment range is reduced at input Output Voltage Sense Range 1 %Vo,nom voltages below 1V Dynamic Response: Recovery Time Transient Voltage.8 1* ms mv di/dt =.1A/uS, Vin=Vin,nom; load step from 5% to 75% of Io,max Output Voltage Overshoot during startup 5 % Vin=Vin,nom; Io=Io,max,Tc=5 C Switching Frequency 7 khz Fixed Output Over Voltage Protection 15 V External Load Capacitance 18& uf Isolation Capacitance.1 uf Isolation Resistance 1 MΩ Ra 36.5 KΩ Required for trim calculation Rb 1 KΩ Required for trim calculation * Engineering estimate & Contact TDK-Lambda for applications that require additional capacitance or very low esr 5/37

Electrical Characteristics: GQAW1A1V: 1V, 1A Output Efficiency, η(%) 94 9 9 88 86 84 8 8.1 1.9.8 3.7 4.6 5.5 6.4 7.3 8. 9.1 1 Vin = 1V Vin = 8V Vin = 4V Power Dissipation (W) 18 16 14 1 1 8 6 4.1 1.9.8 3.7 4.6 5.5 6.4 7.3 8. 9.1 1 Vin = 1V Vin = 8V Vin = 4V Vin = 4V GQAW1A1V Typical Efficiency vs. Input Voltage at Ta=5 degrees. GQAW1A1V Typical Power Dissipation vs. Input Voltage at Ta=5 degrees Input Current (A) 18 16 14 1 1 8 6 4 8 1 16 4 8 3 36 Input Voltage (V) Io_min =.1A Io_mid = 5A Io_max = 1A GQAW1A1V Typical startup characteristic from on/off at full load. Lower trace - on/off signal, upper trace output voltage GQAW1A1V Typical Input Current vs. Input Voltage Characteristics GQAW1A1V Typical startup characteristic from input voltage application at full load. Red trace - output voltage, Blue trace input voltage GQAW1A1V Typical output voltage response to load step from 5% to 75% of full load with output current slew rate of.1a/us and Cext = 5uF 6/37

Electrical Characteristics (continued): GQAW1A1V: 1V, 1A Output 1.5 To be provided in future revision Output Voltage (V) 1 11.5 11 1.5 1.1 5.1 1.1 15.1.1 Vin = 1V Vin = 4V Vin = 3V GQAW1A1V Typical Output Current Limit Characteristics vs. Input Voltage at Ta=5 degrees. GQAW1A1V Typical Output Ripple at nominal Input voltage and full load at Ta=5 degree Output Voltage (V) 1.1 1.8 1.6 1.4 1. 11.98 1 11.96 11.94 11.9 11.9.1 1.9.8 3.7 4.6 5.5 6.4 7.3 8. 9.1 1 Vin = 1V Vin = 4V Vin = 3V % Change of Vout Trim Down Resistor % Change of Vout Trim Up Resistor -5% 647K +5% 6.5K -1% 3K +1% 8.5K e.g. trim up 5% Rup :=.6 36.5 1.6 1 1 1 GQAW1A1V Typical Load Regulation Characteristics at Ta=5 degrees. GQAW1A1V Calculated resistor values for output voltage adjustment Intentionally blank 7/37

Thermal Performance: GQAW1A1V-7: 1V, 1A Output 1 1 8 6 4 NC.5 m/s (1 LFM) 1. m/s ( LFM) 1.5 m/s (3 LFM). m/s (4 LFM) TC Limits 5 45 65 85 15 15 Temperature ( C) GQAW1A1V maximum output current vs. ambient temperature at 4V input for airflow rates natural convection (6lfm) to 4lfm with airflow from pin 3 to pin 1 GQAW1A1V thermal measurement location top view 1 1 8 6 4 5 35 45 55 65 75 85 95 15 115 15 Temperature ( C) GQAW1A1V typical temperature derating versus input voltage output with m/s (4 lfm) airflow from pin 3 to pin 1. GQAW1A1V maximum output current vs. baseplate temperature at nominal line The thermal curves provided are based upon measurements made in TDK Lambda s experimental test setup that is described in the Thermal Management section. Due to the large number of variables in system design, TDK Lambda recommends that the user verify the module s thermal performance in the end application. The critical component should be thermo coupled and monitored, and should not exceed the temperature limit specified in the derating curve above. It is critical that the thermocouple be mounted in a manner that gives direct thermal contact or significant measurement errors may result. TDK Lambda can provide modules with a thermocouple pre-mounted to the critical component for system verification tests. 8/37

Electrical Data: GQAW4A5V-7: 5V, 4A Output Characteristic Min Typ Max Unit Notes & Conditions Output Voltage Initial Setpoint 4.85 5 5.15 Vdc Vin=Vin,nom; Io=Io,max; Tc = 5 C Output Voltage Tolerance 4.8 5 5. Vdc Over all rated input voltage, load, and temperature conditions to end of life Efficiency 9 % Vin=Vin,nom; Io=Io,max; Tc = 5 C Line Regulation.5 % Vin=Vin,min to Vin,max Load Regulation.3 % Io=Io,min to Io,max Temperature Regulation.5 % Tc=Tc,min to Tc,max Output Current.1 4 A At loads less than Io,min the module will continue to regulate the output voltage, but the output ripple may increase Output Current Limiting Threshold 37 A Vo =.9*Vo,nom, Tc<Tc,max Short Circuit Current.3 A Vo =.5V, Tc = 5 C Output Ripple and Noise Voltage 4 15* mvpp 15 mvrms Measured across one uf and one.1uf ceramic capacitor see input/output ripple measurement figure; BW = MHz Output Voltage Adjustment Range 9 11 %Vo,nom Adjustment range is reduced at input Output Voltage Sense Range 1 %Vo,nom voltages below 1V Dynamic Response: Recovery Time Transient Voltage.8 1* ms mv di/dt =.1A/uS, Vin=Vin,nom; load step from 5% to 75% of Io,max Output Voltage Overshoot during startup 5 % Vin=Vin,nom; Io=Io,max,Tc=5 C Switching Frequency 7 khz Fixed Output Over Voltage Protection 6.5 V External Load Capacitance 47 4& uf Isolation Capacitance.1 uf Isolation Resistance 1 MΩ Ra 1 KΩ Required for trim calculation Rb 4. KΩ Required for trim calculation * Engineering estimate & Contact TDK-Lambda for applications that require additional capacitance or very low esr 9/37

Electrical Characteristics: GQAW4A5V-7: 5V, 4A Output Efficiency, η(%) 94 9 9 88 86 84 8 8.4 4.8 7. 9.6 1 14.4 16.8 19. 1.6 4 Power Dissipation (W) 18 16 14 1 1 8 6 4.4 4.8 7. 9.6 1 14.4 16.8 19. 1.6 4 Vin = 1V Vin = 8V Vin = 1V Vin = 8V GQAW4A5V Typical Efficiency vs. Input Voltage at Ta=5 degrees. GQAW4A5V Typical Power Dissipation vs. Input Voltage at Ta=5 degrees Input Current (A) 18 16 14 1 1 8 6 4 8 1 16 4 8 3 36 Input Voltage (V) Io_min =.1A Io_mid = 1A Io_max = 4A GQAW4A5V Typical startup characteristic from on/off at full load. Lower trace - on/off signal, upper trace output voltage GQAW4A5V Typical Input Current vs. Input Voltage Characteristics GQAW4A5V Typical startup characteristic from input voltage application at full load. Red trace - output voltage, Blue trace input voltage GQAW4A5V Typical output voltage response to load step from 5% to 75% of full load with output current slew rate of 1A/uS and Cext = uf 3/37

Electrical Characteristics (continued): GQAW4A5V-7: 5V, 4A Output Output Voltage (V) 5.35 5.3 5.5 5. 5.15 5.1 5.5 5 4 6 8 3 3 34 36 38 4 Vin = 1V Vin = 8V GQAW4A5V Typical Output Current Limit Characteristics vs. Input Voltage at Ta=5 degrees. Output Voltage (V) 5.1 5.8 5.6 5.4 5. 5 4.98 4.96 4.94 4.9 4.9.4 4.8 7. 9.6 1 14.4 16.8 19. 1.6 4 GQAW4A5V Typical Output Ripple at nominal Input voltage and full load at Ta=5 degree % Change of Vout Trim Down Resistor % Change of Vout Trim Up Resistor -5% 16K +5% 19.8K -1% 73.8K +1% 7.8K e.g. trim up 5% Rup :=.6 1 5.5 5 4. 1 Vin = 1V Vin = 8V GQAW4A5V Typical Load Regulation Characteristics at Ta=5 degrees. GQAW4A5V Calculated resistor values for output voltage adjustment Intentionally blank 31/37

Thermal Performance: GQAW4A5V-7: 5V, 4A Output 3 5 15 1 5 NC.5 m/s (1 LFM) 1. m/s ( LFM). m/s (4 LFM) 3. m/s (6 LFM) TC Limits 5 35 45 55 65 75 85 95 15 115 Temperature ( C) GQAW4A5V maximum output current vs. ambient temperature at 8V input for airflow rates natural convection (6lfm) to 6lfm with airflow from pin 3 to pin 1 GQAW4A5V thermal measurement location top view Derating factor 1. 1.1 1.9.8.7.6 3 5 15 1 5.5 5 1 15 5 3 35 4 Vin 5 35 45 55 65 75 85 95 15 115 Temperature ( C) GQAW4A5V typical temperature derating versus input voltage output with m/s (4 lfm) airflow from pin 3 to pin 1. GQAW4A5V maximum output current vs. baseplate temperature at nominal line The thermal curves provided are based upon measurements made in TDK Lambda s experimental test setup that is described in the Thermal Management section. Due to the large number of variables in system design, TDK Lambda recommends that the user verify the module s thermal performance in the end application. The critical component should be thermo coupled and monitored, and should not exceed the temperature limit specified in the derating curve above. It is critical that the thermocouple be mounted in a manner that gives direct thermal contact or significant measurement errors may result. TDK Lambda can provide modules with a thermocouple pre-mounted to the critical component for system verification tests. 3/37

Thermal Management: Adjacent PCB An important part of the overall system design process is thermal management; thermal design must be considered at all levels to ensure good reliability and lifetime of the final system. Superior thermal design and the ability to operate in severe application environments are key elements of a robust, reliable power module. The mechanical design provides a low impedance thermal path from hot components to the base plate, which reduces areas of heat concentration and resulting hot spots. AIRFLOW Module Centerline 76 (3.) A I R F L O W 1.7 (.5) Test Setup: The thermal performance of the power module was evaluated both in cold plate, conduction cooling environments and also in wind tunnel tests using the setup shown in the wind tunnel figure. The thermal test setups are intended to replicate some of the typical thermal environments that could be encountered in modern electronic systems. The power module, as shown in the figure, is mounted on a printed circuit board (PCB) and is vertically oriented within the wind tunnel. The cross section of the airflow passage is rectangular. The spacing between the top of the module and a parallel facing PCB is kept at a constant (.5 in). The power module s orientation with respect to the airflow direction can have an impact on the module s thermal performance. Thermal Derating: For proper application of the power module in a given thermal environment, output current derating curves are provided as a design. The module temperature should be measured in the final system configuration to ensure proper thermal management of the power module. Air Velocity and Ambient Temperature Measurement Location Air Passage Centerline Wind Tunnel Test Setup Figure Dimensions are in millimeters and (inches). In all conditions, the power module should be operated below the maximum operating temperature shown on the derating curve. For improved design margins and enhanced system reliability, the power module may be operated at temperatures below the maximum rated operating temperature. In convection applications, heat transfer can be enhanced by increasing the airflow rate that the power module experiences. The maximum output current of the power module is a function of ambient temperature and airflow For thermal performance verification, the module temperature should be measured at the base plate location indicated in the thermal measurement location figure on the thermal performance page for the power module of interest. 33/37

Operating Information: Over-Current Protection: The power modules have current limit protection to protect the module during output overload and short circuit conditions. During overload conditions, the power modules may protect themselves by entering a hiccup current limit mode. The modules will operate normally once the output current returns to the specified operating range. Output Over-Voltage Protection: The power modules have a maximum duty cycle limit to help reduce the risk of over voltage appearing at the output of the power module during fault conditions. If there is a fault in the voltage regulation loop, the protection circuitry will cause the power module to limit the output voltage. When the condition causing the over-voltage is corrected, the module will operate normally. Thermal Protection: When the power modules exceed the maximum operating temperature, the modules may turn-off to safe-guard against thermal damage. The module will auto restart as the unit is cooled below the over temperature threshold. Remote On/Off: - The power modules have an internal remote on/off circuit. The user must supply an open-collector or compatible switch between the Vin(-) pin and the on/off pin. The maximum voltage generated by the power module at the on/off terminal is 15V. The maximum allowable leakage current of the switch is 5uA. The switch must be capable of maintaining a low signal Von/off < 1.V while sinking 1mA. The standard on/off logic is negative logic. The power module will be off if terminal is left open and will be on if terminal is connected to terminal 3. If the on/off feature is not being used, terminal should be shorted to terminal 3. Vin (+) On/ Off Vin(-) On/Off Circuit for negative logic Output Voltage Adjustment: The output voltage of the power module may be adjusted by using an external resistor connected between the Vout trim terminal (pin 6) and either the Sense (+) or Sense (-) terminal or the Vout(+) and Vout(-) terminals if the sense feature is not populated. If the output voltage adjustment feature is not used, pin 6 should be left open. Care should be taken to avoid injecting noise into the power module s trim pin. Vout(+) Sense(+) Trim Sense(-) Vout(-) Circuit to increase output voltage With a resistor between the trim and Sense (+) or Vout(+) terminals, the output voltage is adjusted down. To adjust the output voltage down a percentage of Vout (%Vo) from Vo,nom, the trim resistor should be chosen according to the following equation: Rdown := Ra ( Votrimdown.6) Vonom Votrimdown Rb 1 34/37

The current limit set point does not increase as the module is trimmed down, so the available output power is reduced. Vout(+) Sense(+) Remote Sense: Some GQA power modules feature remote sense to compensate for the effect of output distribution drops. The output voltage sense range defines the maximum voltage allowed between the Trim Sense(-) Vout(-) Circuit to decrease output voltage With a resistor between the trim and sense (-) or Vout (-) terminals, the output voltage is adjusted up. To adjust the output voltage up a percentage of Vout (%Vo) from Vo,nom the trim resistor should be chosen according to the following equation: For all outputs:.6 Ra Rup := Rb ( Votrimup Vonom) 1 The maximum power available from the power module is fixed. As the output voltage is trimmed up, the maximum output current must be decreased to maintain the maximum rated power of the module. As the output voltage is trimmed, the output over-voltage set point is not adjusted. Trimming the output voltage too high may cause the output over voltage protection circuit to be triggered. To avoid possible damage, care should be taken not to connect the sense (+) or Vout (+) terminals directly to the module s trim pin. output power terminals and output sense terminals, and it is found on the electrical data page for the power module of interest. If the remote sense feature is not being used, the Sense(+) terminal should be connected to the Vo(+) terminal and the Sense (-) terminal should be connected to the Vo(-) terminal. The output voltage at the Vo(+) and Vo(-) terminals can be increased by either the remote sense or the output voltage adjustment feature. The maximum voltage increase allowed is the larger of the remote sense range or the output voltage adjustment range; it is not the sum of both. As the output voltage increases due to the use of the remote sense, the maximum output current must be decreased for the power module to remain below its maximum power rating. EMC Considerations: TDK-Lambda power modules are designed for use in a wide variety of systems and applications. For assistance with designing for EMC compliance, please contact technical support. Input Impedance: The source impedance of the power feeding the DC/DC converter module will interact with the DC/DC converter. To minimize the interaction, a minimum 1uF input capacitor is recommended. 35/37

Input/Output Ripple and Noise Measurements: Battery 1 1uH 1 uf esr<.1 1KHz 1 33uF + Vinput Voutput esr<.7 1KHz - - + 1 Cext 1 RLoad Ground Plane The input reflected ripple is measured with a current probe and oscilloscope. The ripple current is the current through the 1uH inductor. The output ripple measurement is made approximately 9 cm (3.5 in.) from the power module using an oscilloscope and BNC socket. The capacitor Cext is located about 5 cm ( in.) from the power module; its value varies from code to code and is found on the electrical data page for the power module of interest under the ripple & noise voltage specification in the Notes & Conditions column. Reliability: The power modules are designed using TDK-Lambda s stringent design guidelines for component derating, product qualification, and design reviews. Early failures are screened out by both burn-in and an automated final test. Improper handling or cleaning processes can adversely affect the appearance, testability, and reliability of the power modules. Contact technical support for guidance regarding proper handling, cleaning, and soldering of TDK Lambda s power modules. 36/37

Safety Considerations: As of the publishing date, certain safety agency approvals may have been received on the GQA series and others may still be pending. Check with TDK Lambda for the latest status of safety approval on the GQA product line. For safety agency approval of the system in which the DC-DC power module is installed, the power module must be installed in compliance with the creepage and clearance requirements of the safety agency. The isolation is operational insulation. Care must be taken to maintain minimum creepage and clearance distances when routing traces near the power module. As part of the production process, the power modules are hi-pot tested between primary and secondary and from primary and secondary to base plate. To preserve maximum flexibility, the power modules are not internally fused. An external input line normal blow fuse with a maximum value of 3A is required by safety agencies. A lower value fuse can be selected based upon the maximum dc input current and maximum inrush energy of the power module. The power module meets all of the requirements for SELV, provided that the input meets SELV requirements. Warranty: TDK Lambda s comprehensive line of power solutions includes efficient, high-density DC- DC converters. TDK Lambda offers a three-year limited warranty. Complete warranty information is listed on our web site or is available upon request from TDK Lambda. 41 Mile Cars Way, Suite 15 National City, CA 9195 Phone (8)56-34 Toll Free Lambda.TechSupport@us.tdk-lambda.com www.us.tdk-lambda.com/lp/ Information furnished by TDK Lambda is believed to be accurate and reliable. However, TDK Lambda assumes no responsibility for its use, nor for any infringement of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TDK Lambda. TDK components are not designed to be used in applications, such as life support systems, wherein failure or malfunction could result in injury or death. All sales are subject to TDK Lambda s Terms and Conditions of Sale, which are available upon request. Specifications are subject to change without 37/37