Hydropak Booster Systems. Series motralec

Similar documents
Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

SUBMITTAL DATA WATER PRESSURE BOOSTER SYSTEMS

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

900 Series Split Case Fire Pump Systems

390 Series Multi-Stage Vertical In-Line Centrifugal Pumps

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

Duplex Commercial Pressurizer -DCP

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

Series CC Condensate Units

Cavern Electrical Submersible Pumps

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

University of Houston Master Construction Specifications Insert Project Name

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Packaged Design Day Tank Systems

SMN Double-Suction Axially Split Pump

Series MSC Sewage Chopper Pumps

One & Two Stage Turbine Type Pumps

September 22, 2016 To: All Contractors Re: Boiler Back-Up Fuel Tank System Renovation. Dear Sir:

1000 Series Neptune Booster Systems. Flows to: 20,000+ GPM Heads to: 700+ PSI Temperatures to: 250 F

MODEL 10LH SPECIFICATION

Reliable Packaged Solutions in Plumbing

AquaBoost Packaged Systems

W4100, W4200 & W4300 Electric Pump

Series 4600F. HSC Fire Pumps & Packaged Systems

Commercial Pressure Booster Systems

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

PATTERSON PUMP COMPANY

Goulds 3640 ISO nd Edition/API th Edition API BB2 Two-Stage, Between-Bearing, Radially Split

LPG Pump Catalogue. Auto Gas. Bottling. Transfer. Sterling Fluid Systems Group motralec

ANDRITZ High-Pressure Pump MP Series

SECTION VARIABLE FREQUENCY DRIVE UNITS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

FIRE PUMPS & PACKAGED

Series VSPV-Simplex Booster System

BERMAD Waterworks. Booster Pump Control Valve Active Check Valve. 700 Series. Model 740. Features and Benefits. Major Additional Features

Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover

ITT. Goulds Pumps. AquaForce PRESSURE BOOSTING SIZING GUIDE. Engineered for life. Building and Municipal Applications.

WG / WGS HIGH PRESSURE BOOSTER PUMPS

SECTION MOTORS & MOTOR CONTROLLERS

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

NOVAPLEX Integral. Process Diaphragm Pumps. motralec

DW-DW VOX RICAMBI/SPARE PARTS DWG N 01357

Direct Gas-Fired Heating

BoosterpaQ Hydro MPC-ED Guide Specification

XLE50 FLOW RATE (LPM) Flow Rate (GPM)

SECTION MOTOR CONTROL

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

Multiple vacuum pumps and associated equipment ASME air receiver NEMA 12 multiplex control panel

SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

TECHNICAL BROCHURE BAQUACPC. Aquavar CPC VARIABLE SPEED CENTRIFUGAL PUMP CONTROLLER

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

CLOSED COUPLED CENTRIFUGAL PUMPS

SUBMERSIBLE PUMPS

Series 774 Automatic Skid Package

LIQUID PETROLEUM GAS TANKS. Specialist for liquid petroleum gas tanks 2/3. Production and quality 4/5. Heavy-duty and liquid gas tanks 6

Peerless Pump FIRE PUMPS. Horizontal Split-Case, Vertical Turbine, In-Line and End Suction. Sterling Fluid Systems (USA), Inc.

SERIES: WG6-2 SELF-PRIMING CENTRIFUGAL PUMPS

BRAQCPC IT T. Goulds Pumps AQUAVAR CPC. Variable Speed Centrifugal Pump Controller. Engineered for life

Duplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, with Steel Cover

Deep Well Pump Control Valve

Multiple vacuum pumps and associated equipment ASME air receiver NEMA 12 multiplex control panel

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

ELECTRIC AND ELECTRONIC ACCESSORIES. motralec

Series: G5-1¼, G6-1¼ RPM - 60Hz. CAPACITIES TO 80 GPM (5 LPS) HEADS TO 135 FEET (41 M)

SECTION H3 TRAYMASTER SERIES DEAERATORS

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

Series: GA6-1½, GA6-2, GA7-1¼, GA7-1½

Mizer Single Pump and Starter Box

motralec KRAL Pumps with Magnetic Coupling for Marine Applications.

SUGGESTED SPECIFICATIONS Pump Frames NS3 thru OMC5

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM. franklinwater.com

UD SERIES COMPRESSORS

Series: GA6-1½, GA6-2, GA7-1¼, GA7-1½

SINCE Double Suction Split Case Fire Pump. Series 4800 & (New Generation) 001-cat f

Application Engineering

Series: G5-1¼, G6-1¼ RPM - 60Hz. CAPACITIES TO 80 GPM (5 LPS) HEADS TO 135 FEET (41 M)

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM

Multi-Institutional Academic Health Science & Research Center Evansville, IN

ROGERS MACHINERY COMPANY, INC

MAN. Single-channel open impeller. motralec. electrical submersible pumps. General characteristics

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

DSZ3. EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

BOOSTER PUMPS PRODUCT FAMILY APPLICATIONS FAMILY COMPARISON CHART

Peerless Pump FULL PRODUCT LINE. Brochure B Sterling Fluid Systems (USA), Inc.

TECHNICAL BROCHURE B36/3742 R2 3642/3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

Axial and Mixed Flow Pumps for Large Volume Pumping

Climas y Proyectos Leyco, S.A. de C.V.

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

TYPE PC Propeller Condensate Pumps

Contents. Identification

Installation, Operation & Maintenance Manual Control Panels for Automatic Self-Cleaning Strainers Model 596 and Model 2596

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

Transcription:

Series 6000 Hydropak Systems motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com FILE NO: 62.10 DATE: May 23, 2008 SUPERSEDES: 62.10 DATE: Feb. 15, 1999

Series 6000 Engineered, Compact, Ready to Install and Factory Tested System. Model 6722 Armstrong introduces the Series 6000 Hydropak line of packaged booster systems. Series 6000 Hydropak applications include commercial, high rise, industrial and other installations requiring a boost in water pressure. The Series 6000 Hydropak fulfills the need for an engineered, compact, ready to install and factory tested booster system. Responding to flow & pressure demands, the Hydropak is equipped with an autonomous, state of the art control system that provides uninterrupted, unattended pump operation in the most energy efficient way. Benefits Single source responsibility. Fully factory assembled, tested, and UL labeled. Quality engineered components. Compact design minimizes floor space. Standard Series 6500 & 6600 systems for flows up to 500 usgpm are engineered to fit through 34 doorways. Angled Pressure Reducing Valves (PRV s) minimize internal pressure drops. Available piping materials are copper, stainless steel or galvanized steel. Headers are available in copper, stainless steel, steel and cast iron. Header connections supplied grooved or flanged. Savings of up to 30% on annual energy operating costs. Proven Armstrong vertical in-line, end suction (horizontal or vertical), or vertical MultiStage pumps.

Series 6000 Selection Criteria Standard Series 6000 Hydropak packages are designed to satisfy most applications and offer choices as to pump model and type with a basic control logic to allow worry free operation and respond to varying load demands. Series 6500 Maximum flow/usgpm 500 * Pump Series of Pumps Model No. Maximum boost/psi 140 Header sizes - 3 or 4 PRV or check valve sizes 1 1 /2-4 4270 2 6524 3 6534 4280 2 6525 3 6535 Series 6600 Maximum flow/usgpm 1000 Maximum boost/psi 190 Header sizes - 3, 4 or 6 PRV or check valve sizes 1 1 /2-4 * Pump Series of Pumps Model No. 4270 1 6614 2 6624 3 6634 4280 1 6615 2 6625 3 6635 4030 1 6616 2 6626 3 6636 Series 6700 Maximum flow/usgpm 1000 Maximum boost/psi 240 Header sizes - 3, 4 or 6 PRV or check valve sizes 1 1 /2-4 * Pump Series of Pumps Model No. 4360 1 6711 2 6721 3 6731 4380 1 6712 2 6722 3 6732 4300 1 6713 2 6723 3 6733 4700 1 6717 2 6727 * For selection use ArmCalc or ACE Pump select software. 3 6737

Hydropak Systems Custom Packages Armstrong recognizes the need for customized packages. Our team of systems engineers working with the latest technology in Computer Aided Drawing will recommend the optimal system for your specific application, including 50 cycle operation. Model Selection 6XXX Series Of Pumps Series of Pump 1-Simplex 2-Duplex 3-Triplex 5, 6, 7 (See Chart to left) 1-Pump Series 4360 2-Pump Series 4380 3-Pump Series 4300 4-Pump Series 4270 5-Pump Series 4280 6-Pump Series 4030 7-Pump Series 4700 Hydropak Hydrosaver Conventional sizing criteria using equal capacity pumps to satisfy water demand in a multipump system may not result in the most energy efficient arrangement for applications with fluctuating load demands. Hydropak Hydrosaver is a tailored approach to pump selection intended to reduce energy consumption by 5-30% according to the specific duty cycle. A conven tional duplex system, with equal capacity pumps, is limit ed to 2 step operation (50-100%) of demand. For the same application the Hydrosaver would provide 3 step operation (33-67-100%) of demand. Respectively in a triplex system the conventional is limit ed to 3 step (33-67-100%) versus 5 step (20-40-60-80-100%) for the Hydrosaver. Hydropak Standard Equipment Included Pump inlet & outlet isolation valves. Pilot operated pressure reducing valves. Common headers complete with interconnecting pipes & fittings. Thermal bleed circuit consisting of emersion aquastat and solenoid valve. Inlet and outlet pressure gauges. Factory wiring. Calibration and testing of system. Factory mounting and painting of pumps, valves, piping and control panel on base.

Options No flow shut down with drawdown tank (mounted or supplied loose). Allows pumps to be shutdown during periods of no demand. Non-slam check valves in place of pressure reducing valves. Gate valves in place of standard ball valves. Choice of piping and header materials. Individual pump thermal protection. Controls Panel Standard Features UL508/CSA approved. Nema 1 enclosure. Single power supply connection. Across the line magnetic starters. 3 leg motor overload protection (internal reset). Electrical interlock between starters. Current sensing relay sequencing. Motor protector circuit breakers. Minimum run timers. Thermal bleed circuit to activate emersion aquastat and solenoid valve. Low suction pressure protection with indicating light. Power on pilot light. Individual pump running light. Control Panel Options Automatic pump alternation. 24-Hour weekly time clock. Pump elasped time meter. NEMA 12, 3, 4x enclosures. Programmable logic controller. Flow sequencing with impeller wheel type instrument. Pressure sequencing. High suction pressure cut-out. High discharge pressure cut-out. Lead pump failure protection (low discharge pressure). Nighttime shutdown with pressure override. Remote signaling and alarm contacts. Hydrosaver duplex units with 3-step staging. Hydrosaver triplex units with 4-step staging. Hydrosaver triplex units with 5-step staging.

Typical Specifications 1.0 General Furnish and install, as shown on the plans and specifications, an Armstrong Model (Simplex, Duplex or Triplex) Packaged System. Designed for a total system capacity of USgpm with a total discharge head of psi, including a minimum suction pressure of psi. 1.1 Pumps The pumps shall be Armstrong series (4360, 4380, 4300, 4270, 4280, 4030 and 4700) complete with bronze (or resin) fitted dynamically balanced impellers, mechanical seal, (125 or 250) psi suction and discharge flanges, pumps (vertically or horizontally) mounted with (ODP or TEFC) squirrel-cage induction motors suitable for operation with volts, 3 phase, 60 hertz power supply. Pumps shall be of the (vertical in-line, end suction, or vertical multi-stage) design, single stage centrifugal type with cast iron casing. Pumps shall be manufactured by the booster supplier. 1.2 Pumping Details P1 Series: Size:, Capacity: USgpm at feet of head with hp, rpm motor. P2 Series: Size:, Capacity: USgpm at feet of head with hp, rpm motor. P3 Series: Size:, Capacity: USgpm at feet of head with hp, rpm motor. 1.3 Assembly All interconnecting piping to be (type L or K copper, galvanized steel or stainless steel). Common suction and discharge (type L or K copper, galvanized steel, stainless steel, or cast iron) headers with (grooved ends or flange adapter). The assembly shall be complete with bronze ball valves, epoxy coated cast iron combination pilot operated pressure reducing and check valves, 4 diameter 0-200 psi suction and 0-300 psi dis-charge pressure gauges, pump thermal relief circuit including aquastat, solenoid valve, and wiring conduits. 1.4 Control Panel The control panel shall be of the (current sensing relay sequencing or pedal wheel type flow sequencing based on pressure for lead pump and flow for remaining pumps). The complete control panel assembly and all internal devices shall be UL508/CSA approved. The panel shall be complete with NEMA (1, 12, 3 or 4X) enclosure and include door interlocked main disconnect and magnetic motor starters with (fused or fuseless) motor protectors, adjustable time delays, H-O-A selector switch for each pump, power on light, minimum run timers, low suction pressure switch and pilot light, 120 V control transformer with protected control circuit. Control circuit to include fault relay circuit to turn on the next pump should the lead pump fail. 1.5 Testing The system shall be factory assembled, wired, performance tested, calibrated and shipped ready to receive piping and wiring. The entire package shall be UL listed and shall be assembled at an ISO 9001 manufacturing Facility. motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com