WHITE OAK RIDGE PROJECT NO. 53B2384 D-1 DETAIL STANDARD NOTES AND TYPICAL SECTION CITY OF MADISON

Similar documents
2011 LOCAL STREET IMPROVEMENTS

Project Book Worksheet for Cost Estimation

2150 F&I 4" PVC pipe LF 100 $ F&I 6" PVC pipe LF 100 $ F&I 8" PVC pipe LF 100 $ 90.00

DESIGN STANDARDS SECTION DS 3 STREETS

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS

Steese Rd - Curb & Sidewalk Improvement

STREET IMPROVEMENTS PROPOSAL BID ITEMS

For Conduit Inspections

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS

THORNTON ROAD WIDENING PROJECT NO. PW1428 B I D D I N G S C H E D U L E

Austin Constructors, LLC S FM N. Richey 9810 FM 969. Pasadena, TX Austin, TX 78724

HILLS MATERIALS COMPANY UNIT COST TOTAL COST UNIT COST TOTAL COST UNIT COST $294, $294, $74, $74, $35, $35,000.

County of Santa Cruz 0579

SUBTOTAL SITE WORK & DEMOLITION (UTILITIES) $180, $348, $319,943.71

SECTION 17 FIRE HYDRANT ASSEMBLIES General


DELETE first sentence of first paragraph that reads: REPLACE with the following:

CP #CP218 NAIL SOFT GROUND N= E= ELEV= GUY WIRE. + WV CP #CP175 Old Magnail N= E= ELEV=858.

BIDDER'S PROPOSAL (continued) CITY OF BERKELEY BID PROPOSAL ITEM NO. A: BASE BID

Ohio Department of Transportation Official Bid Tabulation Jolene M. Molitoris, Director

CITY AND COUNTY OF DENVER DEPARTMENT OF PUBLIC WORKS Engineering Division PROJECT NO INCA STREET MULTI-USE PATH 38 TH AVE. TO 43 RD AVE.

Units Est. Qty. Unit Price Total Price Unit Price Total Price Unit Price Total Price Unit Price Total Price Unit Price Total Price

CITY OF ESTHERVILLE, IOWA MISCELLANEOUS FEES & CHARGES. At Sewer Main.. $

CITY OF PORTSMOUTH DEPARTMENT OF PUBLIC WORKS (DPW) DRIVEWAY RULES AND PROCEDURES

STANDARD DRAWING INDEX

CITY OF ALAMO HEIGHTS WATER, STREET AND SIDEWALK CAPITAL IMPROVEMENT PROJECTS

Fertilizer Type B 2 CWT $ $ $60.00 $ $60.00 $ Sod Water 60 MGAL $60.60 $3, $30.00 $1, $30.00 $1,

3. Application Fees, Certificate Of Insurance & Performance Bond

Town of Medley Office of Capital Projects & Development Services 7777 NW 72 Avenue, Medley, Florida 33166

BID ITEM ESTIMATED UNIT TOTAL UNIT TOTAL UNIT TOTAL NO. QUANTITY UNIT ITEM COST COST COST COST COST COST

ALEXANDRIA, VIRGINIA PRINCE ST. SUITE 114. ADG, INC. COPYRIGHT c. PH

Date: 04/20/2018 City Project No.: Addendum No.: 4. The following changes shall be made to the project plans and specifications:

CENTENNIAL PARK EXPANSION

(1 ) Active Construction Inc River Road East Tacoma, WA AMOUNT , , ,

Federal Project No.: STP-5128(388)

SPECIAL GRADING INTERSECTION IMPROVEMENT JOHN WARD RD AT IRWIN RD REVISION DATES

SALEM CITY POWER ELECTRICAL REQUIREMENTS & STANDARDS MANUAL

800 Access Control, R/W Use Permits and Drive Design

Grays Ferry Cost Estimate Breakdown Budgetary Numbers for Machinery Drive Options 10 Nov 14

McCRORY & WILLIAMS, INC. HILLCREST ROAD CONNECTOR MCR ROADWAY ITEMS

BID PROPOSAL. Item Description Unit Quantity Unit Price Total Price No. (Unit Price to be written in Words) (Figures) (Figures)

Federal Project No.: OC-095-1(348)

Licensed Class C Virginia Contractor No.

St. Johns River State College BID-SJR Addendum Three ADDENDUM THREE DATED JUNE 13, 2016

PROPOSED 5' HIGH RETAINING KEYSTONE WALL WITH WROUGHT IRON FENCE ON TOP OF WALL PROPOSED SITE LIGHT (TYP.) PROPOSED FIRE HYDRANT 7.0' 9.

BID TABULATION REPORT McKINNEY STREET DRAINAGE IMPROVEMENTS PROJECT No. PWDR10012 BID OPENED : TUESDAY, AUGUST 13, :00 P.M.

Macomb County Department of Roads Bid Comparison

PARKING LOT REHABILITATION PROJECT FOR: SJRSC PALATKA CAMPUS

City of Grand Island Tuesday, February 13, 2018 Council Session

UTILITY CROSSING DETAIL

PROPOSED AMENDMENTS TO RESIDENTIAL PARKING STANDARDS

SAN ANTONIO WATER SYSTEM

METRO Magnolia Transit Center - Bid Tab

VALVES, FIRE HYDRANTS, AND APPURTENANCES

CHAPTER 140 DRIVEWAYS

DRIVEWAY GUIDE. Transportation, Engineering and Development (T.E.D.) Business Group

CONTRACTOR'S REQUEST FOR PAYMENT CHASKA VETERANS PARK IMPROVEMENTS STANTEC PROJECT NO

S T A T E O F M I N N E S O T A D E P A R T M E N T O F T R A N S P O R T A T I O N DATE : 05/01/00 PAGE : 1 TABULATION OF BIDS

Temporary Sales Trailer Application

Installing or Rebuilding Your Electric Service

HARDEE COUNTY ROAD AND BRIDGE DEPARTMENT Driveway-Culvert Installation Permit

Ingham County Request for Proposals Okemos Road and Sandhill Road Widening, Packet #15-15

Oaks Commerce Center

DIVISION 4: STREET. Improvement Design Standards City of Dundee Oregon. Division 4 : Street Page 1

DESCRIPTION QUANTITY PRICE TOTAL

U:\0-PROJECT\Groton - sidewalk\main STREET\MAIN ST CONST-PLAN.dwg, 4/26/ :07:22 AM, AutoCAD PDF (General Documentation).pc3

Patton Hill Road (Four Inch Main), Project No

Ohio Department of Transportation Official Bid Tabulation James G. Beasley, P.E., P.S., Director

PERMANENT RESIDENTIAL UNDERGROUND SERVICE

Purpose: General Provisions:

COMMERCIAL QUICK REFERENCE

Lake County Building Department

VILLAGE OF KENILWORTH, ILLINOIS

ATTACHMENT I BID SCHEDULE IFB NO , CHURCH FARMS EAST STORAGE TANK AND BOOSTER PUMP STATION

SECTION FIRE HYDRANTS WITH HYDRANT LOCKS

Ohio Department of Transportation Official Bid Tabulation Jerry Wray, Director

CITY OF SAN MARCOS ENGINEERING DIVISION

Wentzville Parkway South Phase 2 & 2A

Franklin County Engineer's Office - Highway Design ALKIRE RD & DEMOREST RD ROUNDABOUT CR NO. 11 & CR NO. 25 Bid Tabulation

City of Houston Fondren Road Paving and Drainage

ARTICLE 4 RIGHT-OF-WAY UTILIZATION

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

Application for Service Residential Subdivision / Development

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

PLEASE SUBMIT THE CORRECT PERMIT FEE WITH PAGES 1 & 3 OF APPLICATION TO: OCONTO COUNTY HIGHWAY DEPT, P.O. BOX 138, OCONTO, WI 54153

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (MEAN ROUGHNESS INDEX ACCEPTANCE CRITERIA)

DRIVEWAY/APPROACH PERMIT APPLICATION Applicant Type: Architect/Engineer Contractor Owner

Riverside County Transportation Department Summary of Bids

CT Consultants, Inc.

DRIVEWAY/SIDEWALK PERMIT APPLICATION

Public Works Operations Manual Standard Operating Procedures for Water and Sewer WS - B311 Sanitary Sewer Connection Repair

STATE OF MINNESOTA DEPARTMENT OF TRANSPORTATION - TABULATION OF BIDS. Start Dt: 05/15/17 Comp. Dt: 08/04/17. Contract Time: Min: Max:

SPEED CUSHION POLICY AND INSTALLATION PROCEDURES FOR RESIDENTIAL STREETS

ADDENDUM NO REFERENCE: FORM OF AGREEMENT, Schedule 2 List of Contract Drawings C C C C

BARRETT ROAD (C.R. 178) ROADWAY RESURFACING FROM LEWIS ROAD TO SPAFFORD ROAD IN OLMSTED TOWNSHIP, OHIO ITEMIZED UNIT PRICE BID ROADWAY

Ohio Department of Transportation Official Bid Tabulation Jerry Wray, Director

CITY OF DAVIS PUBLIC WORKS DEPARTMENT STANDARD SPECIFICATIONS

KENT COUNTY ROAD COMMISSION

ORDINANCE NO

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Transcription:

WHITE OAK RIDGE D-1 DETAIL STANDARD NOTES AND TYPICAL SECTION ORIGINATOR:, STREETS DIVISION REV. DATE: PLOT NAME: PLOT SCALE: THE LOCATION AND INFORMATION FOR PROPOSED NEW TREES, IN THE PUBLIC RIGHT OF WAY OR ON PUBLIC LANDS ARE APPROXIMATE AND ARE SHOWN FOR REFERENCE ONLY. THE LOCATIONS, SPECIFICATIONS AND PLANTING METHODS OF ALL PROPOSED NEW OR REPLACEMENT TREES IN THE PUBLIC RIGHT OF WAY OR ON PUBLIC LANDS SHALL BE APPROVED BY THE CITY FORESTER PRIOR TO INSTALLATION. NO TREES IN THE RIGHT OF WAY OR ON PUBLIC LANDS SHALL BE TRIMMED, PRUNED, REMOVED OR ADVERSELY AFFECTED IN ANY WAY UNTIL THE DEVELOPER HAS RECEIVED WRITTEN PERMISSION FROM THE CITY ENGINEER OR CITY FORESTER. SAID WRITTEN PERMISSION SHALL INCLUDE LANGUAGE INDICATING THAT SECTION 10.101 OF THE MADISON GENERAL ORDINANCES AND ADMINISTRATIVE PROCEDURE MEMORANDUM NO. 6-2, REFERING TO NOTIFICATION OF PROPERTY OCCUPANTS AND/OR OWNERS, HAS BEEN COMPLIED WITH. ALL PAVEMENT WITHIN THE DAVENPORT RIGHT-OF-WAY SHALL BE TYPE A PAVEMENT. ALL GUTTERS SHALL DRAIN WITH A MINIMUM GRADES OF 0.5% TOWARD STORM SEWER INLETS. THE CROSS SLOPE OF SIDEWALKS AND BARRIER FREE SIDEWALK CURB RAMPS SHALL BE 2%. THE LONGITUDINAL GRADE OF BARRIER FREE SIDEWALK CURB RAMPS SHALL NOT EXCEED 8.33%. ALL SIDEWALK RAMPS SHALL BE CONSTRUCTED ACCORDING TO S.D.D. 3.03. AT ALL OTHER LOCATIONS THE LONGITUDINAL GRADE OF SIDEWALKS SHALL NOT EXCEED 5.0 % OR THE ADJACENT STREET GRADE WHICHEVER IS GREATER NOR BE LESS THAN 0.4% AND SHALL DRAIN TOWARD STORM SEWER INLETS. SIDE SLOPES WITHIN TEN FEET OF A PUBLIC SIDEWALK SHALL NOT EXCEED 4.00:1. ALL SIDEWALK AND SIDEWALK RAMP ELEVATIONS AND GRADES SHALL BE FIELD VERIFIED AND SET TO COMPLY WITH THE STANDARD SPECIFICATIONS AND THE A.D.A. GUIDELINES. OBTAIN A PRINT OUT OF THE ALIGNMENT FROM THE CITY ENGINEER PRIOR TO STAKING THIS PROJECT. CURB STATION AND OFFSETS SHALL BE TO THE FACE OF CURB UNLESS OTHERWISE INDICATED. CURB ELEVATIONS SHALL BE TO THE TOP OF CURB (OR EXTENDED TOP OF CURB FOR DRIVEWAYS OR RAMPS) UNLESS OTHERWISE INDICATED. POWER POLES AND OTHER OBSTRUCTIONS SHALL BE MOVED TO PROVIDE 2 FEET MINIMUM OF CLEAR DISTANCE FROM ANY FACE OF CURB OR EDGE OF SIDEWALK. ANY INFORMATION SHOWN ON THIS PLAN, WHICH IS NOT PART OF THIS PROJECT, IS PRELIMINARY AND NOT FOR CONSTRUCTION. THERE MAY BE EXISTING UTILITIES OR OTHER FEATURES WHICH ARE EITHER NOT SHOWN OR SHOWN INCORRECTLY ON THIS PLAN. IT IS THE RESPONSIBILITY OF THE DEVELOPER TO LOCATE AND IDENTIFY ALL UTILITIES AND TOPOGRAPHY WHICH MAY AFFECT THE CONSTRUCTION OF THESE IMPROVEMENTS. ALL PERMANENT SIGNING AND POSTING WILL BE DETERMINED AND PROVIDED BY THE TRAFFIC ENGINEERING DIVISION, FOLLOWING CONSTRUCTION OF THESE IMPROVEMENTS. THE DEVELOPER SHALL PROVIDE, INSTALL AND MAINTAIN ALL STREET END BARRICADES, SIGNING AND TRAFFIC CONTROL, AS REQUIRED BY THE CITY TRAFFIC ENGINEER. PAVEMENT SAWCUTS SHALL BE AS DIRECTED BY THE CITY CONSTRUCTION ENGINEER. SAWCUTS SHOWN ON THE PLAN ARE APPROXIMATE. DAMAGE TO ANY EXISTING CURB, PAVEMENT, SIDEWALK, ETC. THAT IS TO REMAIN SHALL BE REPAIRED BY THE DEVELOPER/CONTRACTOR AS DIRECTED BY THE ENGINEER. M:\DESIGN\Projects\53B2384\Streets\Design\53B2384EN_Details##.dgn DATE: 9/29/2014

WHITE OAK RIDGE D-2 DETAIL ROW 60' ROW TYPICAL SECTION CL 0.67' 5.33' 8' 16' 16' 8' 5.33' 0.67' POINT REFERRED INSTALL 5" CONC. SIDEWALK 2.00% 4% VAR. TO ON PROFILE VAR. 4% 2.00% INSTALL 5" CONC. SIDEWALK ORIGINATOR:, STREETS DIVISION REV. DATE: PLOT NAME: PLOT SCALE: TYPE ROW VAR., 8.00% MAX * MINIMUM PAVEMENT DESIGN CRUSHED AGG. BASE COURSE LOWER LAYER GRADATION 1 UPPER LAYER GRADATION 2 A 6" 4" B 6" 4" C 6" 4" 4" TOPSOIL, SEED & MAT (TYP.) TYPE 'A' CONCRETE CURB & GUTTER VAR. 14'-16' 4" TOPSOIL, SEED & MAT (TYP.) TYPE 'A' CONCRETE CURB & GUTTER ASPHALTIC CONCRETE PAVEMENT LOWER LAYER UPPER LAYER TYPE THICKNESS TYPE THICKNESS E-0.3 1.75" E-0.3 1.75 " E-1 2.50" E-1 1.75 " E-3 3.50" E-3 1.75 " VAR. CRUSHED AGGREGATE BASE COURSE (TYP)* ASPHALTIC CONCRETE PAVEMENT UPPER LAYER (TYP)* ASPHALTIC CONCRETE PAVEMENT LOWER LAYER (TYP)* TYPICAL SECTION DAVENPORT DRIVE STA 12+69 TO STA 12+84 NOT TO SCALE VAR. 60'-100' CL VAR. 16'-35.5' VAR. 16'-35.5' POINT REFERRED TO ON PROFILE CRUSHED AGGREGATE BASE COURSE (TYP)* ASPHALTIC CONCRETE PAVEMENT UPPER LAYER (TYP)* ASPHALTIC CONCRETE PAVEMENT LOWER LAYER (TYP)* TYPICAL SECTION DAVENPORT DRIVE STA 12+84 TO STA 13+83 NOT TO SCALE VAR. 4" TOPSOIL, SEED & MAT (TYP.) TYPE 'A' CONCRETE CURB & GUTTER ROW VAR. 14'-16' VAR., 8.00% MAX 4" TOPSOIL, SEED & MAT (TYP.) TYPE 'A' CONCRETE CURB & GUTTER NOTES: * A PAVEMENT DESIGN IN ACCORDANCE WITH STANDARD DETAIL DRAWING 4.06 IS REQUIRED ON ALL PROJECTS TYPE 'A' PAVEMENT SHALL BE USED ON DAVENPORT DRIVE M:\DESIGN\Projects\53B2384\Streets\Design\53B2384EN_TypSection.dgn DATE: 10/1/2014

WHITE OAK RIDGE P-1 PLAN AND PROFILE DAVENPORT DRIVE EX-WELL 1 2 EX-SEPTIC VENT REV. DATE: PLOT NAME: PLOT SCALE: 0708-361-0913-6 WALLACE, DAVID R & LAUREN A TREPANIER 6202 DAVENPORT DR 0708-361-1002-6 MCLAUGHLIN, SEAN P NICHOLE A WEINFURTNER 6201 DAVENPORT DR 0708-361-0914-4 BEAULIEU, ANDREW P 6110 DAVENPORT DR 0708-361-1001-8 WS EX-SAN. MH RIM=1058.78 (W) INV.=1050.64 (E) INV.=1050.64 6-IN C.I. (1961) WELLINGTON VENTURES LLC # 113 6109 DAVENPORT DR SAN 7 6 5 3 20' WIDE PRIVATE WATER MAIN AND SANITARY SEWER EASEMENT. SEE SEPERATE EASEMENT AGREEMENT FOR ADDITIONAL RIGHTS AND RESPONSIBILITIES. DAVENPORT DR 12+00 13+00 14+00 15+00 16+00 17+00 17+49 1085 1080 STA 12+63.70, LT 16.00' MATCH EX. CURB STA 12+63.70, RT 16.00' MATCH EX. CURB STA 12+84.21, LT 29.33' 1059.30 BW/KEYSTONE STA 12+69.21, LT 29.33' MATCH EX. SIDEWALK SAW CUT STA 12+69.21, RT 28.88' MATCH EX. SIDEWALK STA 12+84.21, RT 28.88' 1059.30 BW/KEYSTONE STA 12+98.70, LT 16.00' 1059.74 TC/PT R 36.5' STA 13+23.68, LT 25.89' 1061.14 TC/PRC R 36.5' STA 13+23.68, RT 25.89' 1061.14 TC/PRC STA 12+98.70, RT 16.00' 1059.74 TC/PC TY 'A' CURB STA 13+62.07, LT 32.58' 1062.52 TC/QC R35.5' STA 13+83.47, 0.00 1063.17 TC/MC HI POINT STA 13+62.07, RT 32.58' 1062.52 TC/QC 1085 1080 10' NOTE: INSTALL MOUNTABLE CURB ON CUL-DE-SAC PER S.D.D. 3.05 4 17+49.38 POE 1075 1075 ORIGINATOR:, STREETS DIVISION 1070 1065 1060 1055 1050 1045 1040 1055.67 1056.63 1057.75 EX. GROUND PROFILE AT CENTERLINE VPI 12+63.70 1058.32 PR. CENTERLINE ELEVATION EX. GROUND ELEVATION AT CENTERLINE 1058.73 1058.88 1061.63 12+00 13+00 14+00 1060.13 VPI 13+13.00 1060.78 1062.86 1061.26 VPI 13+48.00 1062.18 4.99% 4.00% 3.00% 1065.73 1062.24 1070.35 VPI 13+81.00 1063.17 PR. CENTERLINE PROFILE 1062.99 1074.80 1070 1065 1060 1055 1050 1045 1040 M:\DESIGN\Projects\53B2384\Streets\Design\53B2384EN-PnP-Davenport.dgn DATE: 10/1/2014

WHITE OAK RIDGE U-1 1 2 DAVENPORT DR UTILITY PLAN AND PROFILE 0708-361-0912-8 DUNN TRUST, THOMAS &JOAN 6206 Davenport Dr 0708-361-0913-6 WALLACE, DAVID R &LAUREN A TREPANIER 6202 DAVENPORT DR 0708-361-0914-4 BEAULIEU, ANDREW P 6110 DAVENPORT DR 3 4 REV. DATE: PLOT NAME: PLOT SCALE: 0708-361-1003-4 MORGAN, RICHARD &JO ANN 6205 Davenport Dr 1085 1080 DAVENPORT DR WS 6-IN C.I. (1961) 7 6 5 20' WIDE PRIVATE WATER MAIN AND SANITARY SEWER EASEMENT. SEE SEPERATE EASEMENT AGREEMENT FOR ADDITIONALRIGHTS AND RESPONSIBILITIES. 11+00 12+00 13+00 14+00 15+00 16+00 0708-361-1002-6 MCLAUGHLIN, SEAN P EX 8" SAN VP NICHOLE A WEINFURTNER 6201 DAVENPORT DR 0708-361-1001-8 WELLINGTON VENTURES LLC # 113 6109 DAVENPORT DR SAS #1 SAN REM EX SAS #3063-005 95' - 8"PVC @ 2.00% PROPOSED WATER (SEE WATER PLAN) SAS #2 4" STUBS 10' INSTALL 4" SAN LATERAL 3' OFF EASEMENT CENTERLINE NOTE: LATERAL LOCATIONS TO BE DETERMINED BY DEVELOPER'S ENGINEER. 1085 1080 1075 EXISTING R.L. GRADE 1075 1070 PROPOSED R.L. GRADE 1070 ORIGINATOR:, STREETS DIVISION 1065 1060 1055 1050 1045 1040 EX 8"SAN VP REM EX SAS #3063-005 STA 12+75.15, RT-0.22' EX RIM = 1058.78 EI(E) = 1050.64 (8") EI(W) = 1050.64 (8") PROPOSED WATER (SEE WATER PLAN) 95' - 8"PVC @ 2.00% SAS #2 STA 13+70.07, RT-4.09' SAS #1 RIM = 1062.90 STA 12+75.00, RT-0.22' EI(W) = 1052.65 (8") RIM = 1058.89 EI(N) = 1052.75 (4") LAT EI(W) = 1050.64 (8") EI(E) = 1052.75 (4") LAT. EI(E) = 1050.75 (8") EI(S) = 1052.75 (4") LAT. 11+00 12+00 13+00 14+00 15+00 16+00 1065 1060 1055 1050 1045 1040 M:\DESIGN\Projects\53B2384\Sanitary\Design\53B2384SAN-PnP##1.dgn DATE: 9/30/2014

1020 1101 1022 1025 1013 74 1026 1017 P LO T S C A LE: WHITE OAK RIDGE WATER IMPACT PLAN W-2 80 32 1025 1109 1102 1113 1106 6210 6206 6202 6110 V-3 36 1110 DAVENPORT DR R E V. D A T E: P LO T N A M E: 1125 1121 1117 1118 1122 1114 HATHAW AY DR 6209 6210 6202 6205 6201 6109 CUT-IN 6-IN VALVE -TURN VALVES: *V-3 -NOTIFY: *DAVENPORT DR. (ALL) 40 1126 1121 6201 6026 6022 6014 6010 6006 6002 O R IG IN A T O R : C IT Y O F M A D IS O N, S T R E E T S D IV IS IO N 6301 1125 DISCLAIMER NOTE: THE WATER IMPACT PLAN IS PROVIDED FOR REFERENCE PURPOSES TO AIDE PLANNING CONNECTION POINT ISOLATION AND PREPARING NOTIFICATION LISTS DURING PLANNED OUTAGES. REQUEST ANY ALTERNATIVE CONNECTION METHODS IN WRITING, PER SPECS. 6217 6202 6205 DATE: 1106 1110 1102 1109 6025 6017 6013 6009 6005 1101 1105

M:\DESIGN\Projects\53B2384\Water\Design\53B2384WU-Materials.dgn 9/5/2014 WHITE OAK RIDGE W-3 CONSTRUCTION NOTES: WATER ESTIMATE OF MATERIALS 1. CONSTRUCT NEW WATER MAIN 6.0 BELOW FINISHED GRADE, UNLESS OTHERWISE NOTED. INSULATE MAIN WITH POLYSTYRENE BOARD AT UTILITY CROSSINGS OR OTHER AREAS IDENTIFIED BY ENGINEER AS HAVING INADEQUATE COVER. 2. VERIFY SIZE OF EXISTING WATER SERVICES AND RECONNECT SERVICES AS INDICATED. 3. MINIMIZE DISTRUPTION OF SERVICE TO EXISTING CUSTOMERS. NOTIFY PER CONTRACT REQUIREMENTS OF ANY PLANNED WATER OUTAGE. WN1 REPLACE THE EXISTING LEAD SERVICE WITH A NEW COPPER SERVICE. WN2 EXTEND AND RECONNECT THE EXISTING COPPER SERVICE TO THE NEW WATER MAIN. WN3 EXISTING SERVICE TO BE ABANDONED WHEN THE WATER MAIN IS CUT OFF. WN4 DISCONNECT FROM THE OLD WATER MAIN AND RECONNECT THE EXISTING COPPER WATER SERVICE LATERAL TO THE NEW WATER MAIN. WN5 RELOCATE THE EXISTING FIRE HYDRANT. REQUIRED BEARING AREA PER STANDARD SPECIFICATION SECTION 703 REV. DATE: PLOT NAME: PLOT SCALE: 4. THE EXISTING UTILITIES SHOWN ON THIS PLAN REPRESENT THE BEST INFORMATION AVAILABLE TO THE WATER UTILITY AT THE TIME OF PLAN PREPARATION. CONTRACTOR IS RESPONSIBLE FOR HAVING EACH UTILITY LOCATED PRIOR TO COMMENCING WORK. ESTIMATE OF MATERIALS SUPPLIED BY CONTRACTOR: * ESTIMATE OF MATERIALS IS FOR INFORMATION ONLY. ENGINEER DOES NOT GUARANTEE ACCURACY OF MATERIAL TAKE-OFF. 40-FT - 6-IN PIPE 110-FT - 8-IN PIPE 180-FT - POLYWRAP 2-6-IN VALVE & BOX 1-6-IN 90 BEND 1-8-IN 45 BEND 1-8-IN X 6-IN TEE WN6 ABANDON WATER VALVE ACCESS STRUCTURE. WN7 FURNISH AND INSTALL THE NEW TOP SECTION FOR THE WATER ACCESS STRUCTURE. WN8 ABANDON THE VALVE BOX. WN9 FURNISH THE DITCH, COMPACTION, AND ALL MATERIALS AND LABOR FOR THE INSTALLATION OF NEW SERVICE LATERAL. WN10 REMOVE AND SALVAGE EXISTING HYDRANT WN11 REPLACE THE EXISTING COPPER SERVICE WITH A COPPER SERVICE WN20+ SEE WATER IMPACT PLAN FOR CONNECTION POINT ISOLATION AND WATER SHUT-OFF NOTFICATION INFORMATION. MIN. 24" OR AS REQUIRED BYDRAWINGS OR FIELD CONDITIONS. BURY LINE ON HYDRANT SHALL BE AT FINISHED GRADE OR WITHIN +3 INCHES. DO NOT DISH OUT OR BUILD UP GRADE AROUND HYDRANT TO MEET REQUIREMENT. GROUND RoDon HIGH- VISIBILITY LOCATING DEVICE W/ A BOLT-ON FLAT STEEL MOUNTING BRACKET. STANDARD 5 LENGTH. FOR MORE DETAILS SEE RoDonCorp.com BENDS TEE REVISED 12/2013 UNDISTURBED SOIL PLUGGED CROSS POURED CONCRETE HYDRANT PLUGGED TEE WATER UTILITY STANDARD CONCRETE BLOCK THRUST RESTRAINT STANDARD DETAIL DRAWING 7.03 (A) 1-8-IN X 6-IN REDUCER ORIGINATOR:, STREETS DIVISION DISCLAIMER NOTE: 1-8-IN MJ PLUG 1-5-IN HYDRANT 1-IN COPPER TUBING (AS REQUIRED) 1 -IN COPPER TUBING (AS REQUIRED) SALVAGED MATERIALS 1-5-IN HYDRANT UTILITY LOCATIONS SHOWN ARE APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR S RESPONSIBILITY TO DETERMINE THE EXACT HORIZONTAL AND VERTICAL LOCATION OF ALL EXISTING UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO COMMENCING WORK. TO OBTAIN LOCATION OF PARTICIPANTS UNDERGROUND FACILITIES BEFORE YOU DIG IN WISCONSIN CALL DIGGERS HOTLINE TOLL FREE 811 OR 1-800-242-8511 FAX-A-LOCATE 1-800-338-3860 TDD (FOR HEARING IMPAIRED) 1-800-542-2289 WIS. STATUTE 182.0175 (1974) REQUIRES MIN. OF 3 WORK DAYS NOTICE BEFORE YOU EXCAVATE. ONE CALL SY MEMBER STEMS INTER NATIONAL 6" VALVE & BOX (IF INDICATED ON PLAN DRAWINGS) HYDRANT LEAD 6-0" MIN. RESTRAIN ENTIRE LENGTH OF HYDRANT LEAD FROM THE TEE THROUGH THE VALVE TO THE HYDRANT AS SPECIFIED USING RESTRAINED JOINT FLANGES PER SPECIFICATION 702.6, SEE DRAWING 7.03. JOINT REDTRAINTS, PER DRAWING 7.03. SOLID CONCRETE MASONRY UNIT 4 X4 MIN SIZE, 6 MIL. POLY- ETHYLENE FILM OR GEOTEXTILE FABRIC. 1" WASHED STONE, 1 MIN. 2 C.Y. POURED CONCRETE OR SOLID CON- CRETE BLOCK TO UNDISTURBED SOIL. WATER UTILITY TYPICAL HYDRANT INSTALLATION REVISED 12/2013 STANDARD DETAIL DRAWING 7.04 STYROFOAM SHEET 2" THICK X 4 WIDE X 8 LONG (TYPICAL) NOTES: 1) ALL STYROFOAM TO BE 2" HIGH DENSITY POLYSTRENE BOARD REVISED 1/2009 4 2 6" MIN. COVER VARIES WATER UTILITY TYPICAL STYROFOAM INSTALLATION STANDARD DETAIL DRAWING 7.05 DATE: