Dangerous Goods. Transport Tanks

Similar documents
Dangerous Goods. Transport Tanks

Vehicle Care and Maintenance

EXPLANATORY NOTE LIQUIFIED PETROLEUM GASES TRANSPORTED IN STATIONARY TANKS PERMANENTLY MOUNTED ON TRAILERS

Types Of Containers. Introduction. Multi Mode. Standard. The Standard International Box. Emergency Response Solutions

In addition to the definitions contained in 171.8, (a) and of this subchapter, the following definitions apply to this subpart:

June 22, 2017 Nashville, TN

LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001)

Fuels Safety Division. Propane Code Adoption Document Amendment

ENVIRONMENTAL FIELD PROCEDURE EFP 06 FUEL HANDLING

2 2 Small Mobile (Truck Box) Tanks 450L Ancillary tank located in the box of a pickup truck used to transport, store and dispense fuel

Outline. Purpose. TDG Regulatory Update

Federal Motor Carrier Safety Regulations

Rules Respecting Key Trains and Key Routes

Permit Holder. Permitted Equipment

Provincial Railway Guides Section:

RULE LIQUEFIED PETROLEUM GAS TRANSFER OR DISPENSING (Adopted 1/13/2015)

Environmental Management System

Awareness Session - Proposed Regulatory Changes. AAR BOE Hazmat Seminar May 2014

APPROVAL GUIDE CSA 3.16

Transportation of Dangerous Goods (TDG) - Transport des marchandises dangereuses (TMD)

TRANSFER FLOW INCORPORATED INSTRUCTION SHEET NUMBER 374 IS DEPARTMENT OF TRANSPORTATION SPECIAL PERMIT SP

Tax and Revenue Administration (TRA)

BUREAU OF STANDARDS. Effective Date: 8/19/2016 Section No. 4. Version: 1.2 Procedure No. 3

Natural Gas for Transportation Codes & Standards Issues

Equivalency Certificate (Approval issued by the competent authority of Canada)

Portable. Storage and Transport Dewars. CL/CLPB Series, CH Series, CFN/CFL Series

Transportation and Transfer

These regulations are created pursuant to and of the Colorado Revised Statutes.

PRESSURE EQUIPMENT EXEMPTION ORDER

.4 Emergency and normal vents and terminations. .1 CAN/CSA-B139-09, Installation Code for Oil Burning Equipment.

Date. Director c/o Petroleum Storage Program Manitoba Conservation and Water Stewardship 1007 Century Street Winnipeg, MB R3H 0W4

North American Automatic Manual Reset and Motorized Valves

Fuel Tank Management: PBS, USTs and the Energy Policy Act of 2005

Permit Holder. Permitted Equipment

TRANSFER OF ORGANIC COMPOUNDS INTO MOBILE TRANSPORT TANKS (Effect: 5/6/77: Rev. Effect. 7/26/00)

ASSOCIATION OF AMERICAN RAILROADS BUREAU OF EXPLOSIVES

New West Partnership Deliverables July 2011/2012 Reporting

PETROLEUM PRODUCTS ACT REGULATIONS

MSC Guidelines for Fired Thermal Fluid Heaters Procedure Number: E1-28 Revision Date: April 20, 2018

Western Plant Health Association Anhydrous Ammonia Facility / Field Tank Safety Self Inspection Safety Checklist Form

TECHNICAL SPECIFICATION CLIENT : MCM

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT. Guideline for Expedited Application Review (GEAR) Oil Field Sump Replacement Tanks

4. No person shall install a coaxial Phase I vapor recovery system unless the system was certified by CARB after January 1, 1994.

Report No.: Name of Ship: Plans referred during Initial Survey:

e-cfr data is current as of January 5, 2017

Silhouettes of Rail Cars, Tank Trucks and Chemical Tanks

Mandatory Entry Level Training for Class 1 drivers Agriculture industry

NZ Oil Industry Safe Loading Pass Guide Notes. Mounted Tank, Trailer, Semi Trailer and Ancillary

Summaries for Gasoline Distribution Facilities and Gasoline Dispensing Facilities 40 CFR 63 subpart BBBBBB and 40 CFR 63 subpart CCCCCC

The purpose of this rule is to limit VOC emissions from the transfer of organic liquids.

Transportation and Transfer

Joint Meeting Standards Working Group Report of the second meeting, Bern, March 2003

Dairy Transport Assurance Scheme

1) Activity Description: Management of Petroleum Storage Tanks and Containers

Powered Industrial Trucks

Propane 101. Study Guide. Course Code: 8517

Laboratory Evaluation Report for: Backflow Preventer for Beverage Dispensing Equipment

Weight Allowance Reduction for Quad-Axle Trailers. CVSE Director Decision

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

ALBERTA CARBON LEVY. Impact of Producers, Marketers and Users of Fuel. December 15, 2016 Craig McDougall, QC / Peter Mitchell, CA Felesky Flynn LLP

AST REGISTRATION PIPE INSPECTION PE REQUIREMENTS. David D. Bradeson, P.E. Chemung Contracting Corporation

49 CFR Updates Dangerous Goods Symposium September 6, Brian Beetz Manager, Regulatory Affairs & Corporate Responsibility

HOLY SPIRIT RCSRD NO.4 BUS DRIVER S GUIDE

Module 4: Weights and Dimensions

CHAPTER 115 LEAK DETECTION AND REPAIR (LDAR) PROGRAM CHANGES

CHAPTER 403. HAZARDOUS MATERIAL TRANSPORTATION

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

Grant Guidelines To States For Implementing The Secondary Containment Provision Of The Energy Policy Act Of 2005

for the DOT Safety Audit (SA) Compliance Review (CR) or New CSA Streamlined Review (SR)

Chapter 2. The Vehicle-Tank Metering System

Agency Information Collection Activity Under OMB Review. AGENCY: National Highway Traffic Safety Administration (NHTSA),

Tank Truck Product Integrity Protection Guidelines 4 th Edition, Revision 1 August 27, Normal Alpha Olefins Polyalphaolefins

Specification Sheet Form Rev

SPCC Regulation Integrity and Leak Testing Methods

Nurse Tank Inspection Report Instructions

Multi-Sector Air Pollutants Regulations (MSAPR) May 2017

Rule No. 1. Scope Definitions Periodicity of technical inspections Technical inspection Inspection requirements...

Type 5 10k 700 cc PED DOT TC

CLOSURE DIMENSIONS SIZES 6-12 CLASS 150/900TV VERTICAL WITH HINGE SIZES 6-12 CLASS 150/900TH HORIZONTAL WITH HINGE

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

IFC Chapter 61, NFPA 58 LP Gas

Worcester Controls Directional Ball Valves

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

Specification Sheet Form Rev

Codes, Standards and Advisories Applicable to Natural Gas Vehicles and Infrastructure (N.B. This list is not all-inclusive)

SPECIFICATION S 42m3 Tridem

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

TROXELL COMPANY, INC E. HWY. 114 RHOME, TEXAS 76078

Polypropylene Piston Drum Pumps

ANNUAL REPORT TO THE LEGISLATIVE ASSEMBLY FOR 2016 UNDER THE TRANSPORTATION OF DANGEROUS GOODS ACT

Part Inspection, Repair, and Maintenance

Licence No. / Licence no MBC Issue Date / Date de deliverance Revised Revised Revised Revised

Powered Industrial Vehicle Policy

Electrical Power Generator Use and Procurement Guidance

August 31, 2011 CPC-1232

RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF SHIPS IDENTIFIED BY THEIR MISSIONS CHAPTERS APPROACH

STATIONARY GAS TURBINE ENGINES - REASONABLY AVAILABLE CONTROL TECHNOLOGY (Adopted & Effective 9/27/94) (Rev. Adopted & Effective 12/16/98)

TIME TASK FORCE. Guidelines for the Mitigation of Motor Vehicle Fluid Spills at Crash Scenes (Non-Cargo)

Boyd Stephenson Director of Hazmat & Driver Licensing American Trucking Associations

Requirements for Dispensing of Compressed Natural Gas. Yvonne Espinoza, PE Austin Fire Department Engineering Services

Transcription:

Dangerous Goods and Rail Safety Dangerous Goods, Rail Safety & 511 A Technical Publication from the Co-ordination and Information Centre Dangerous Goods Transport Tanks July 2017

- 1 - This material is meant as a guide to certain parts of the Transportation of Dangerous Goods Regulations and is not meant to be a substitute for them. It is the responsibility of handlers, offerers and transporters of dangerous goods to consult the Regulations for the exact requirements. The Coordination and Information Centre of can provide accurate information regarding the Regulations 24 hours a day. Co-ordination and Information Centre Dangerous Goods and Rail Safety Main Floor, Twin Atria Building 4999 98 Avenue Edmonton, Alberta, T6B 2X3 Tel. Edmonton: (780) 422 9600 Tel. Province-wide: 1 (800) 272 9600 Fax: (780) 427 1044 These telephone lines are recorded to assist in responding to the emergency (natural/manmade) and/or inquiry regarding dangerous goods and to ensure that the information is accurate. Direct any questions regarding the recording to the Compliance Officer responding to your call or contact the Manager of the CIC at 780-427-8660. Legal Authority: Dangerous Goods Transportation and Handling Act, Section 13(1).

- 2 - Bulk Transport Tanks There are two pieces of legislation which cover the use of bulk tanks for transporting dangerous goods: the federal Transportation of Dangerous Goods Regulations; and the Dangerous Goods Transportation and Handling Regulation. The provincial regulations adopt the federal regulations to maintain consistency of the rules within all of Canada for moving dangerous goods. Federal Legislation Part 5.10 requires that anyone offering for transport or transporting Class 2 gases in large tanks comply with the selection and use criteria set out in CSA Standard B622. Part 5.14 requires that anyone offering for transport or transporting Class 3, 4, 5, 6.1, 8 and 9 dangerous goods in large tanks comply with the selection and use criteria set out in CSA Standard B621. These two standards allow the shipper and the carrier of dangerous goods to select the correct type of tank to use for each dangerous good. Both standards refer to the manufacturing standard CSA B620, which outlines how a tank must be constructed and maintained for continued dangerous goods service. All tanks constructed after July 1, 1995 must be built to standard. Only facilities that are registered with Transport Canada can manufacture, assemble, modify, repair or test tanks that are used to transport dangerous goods. A list of registered facilities is available on the Transport Canada website. http://wwwapps.tc.gc.ca/saf-sec-sur/3/fdr-rici/highway/tanks.aspx US Tanks Tanks built in the US to the US Department of Transport standard set out in the Code of Federal Regulations (CFR) Title 49 will have information on identification plates that is similar to their Canadian equivalent tanks. They will be marked MC or DOT instead of the TC mark used in Canada. These tanks are considered equivalent to a tank designed to the Canadian standard and, providing they are built in the US or built before August 31, 2008 in Canada, they can be used in Canada. After August 31, 2008 tanks manufactured in Canada, for use in Canada, must be constructed and maintained according to CSA B620.

- 3 - Tank Types TC 406/306 low pressure, oval shaped, highway tank for general flammable liquids including gasoline, crude oil and diesel. They operate at about atmospheric pressure or 21 kpa (3 psi). It should be noted that TC 406 and TC 306 used in petroleum crude oil service may differ from units used for gasoline and other flammable liquids. There may be design changes such as no internal automatic safety shut off valves. These units are marked TC 306 Crude or TC 406 Crude and are to be used solely for the purposes of transporting crude oil, tars, asphalts, oils, bitumen and cutbacks. Safety features on these tanks include rollover protection by means of a trough at the top of the tank to prevent damage to manholes and vents. Other features include high strength bumpers, safety relief vents and internal baffles to minimize liquid surge and provide added strength to the barrel of the tank. Some tanks have more than one compartment. A void section often separates these compartments to prevent contamination between compartments. These voids must be open to atmosphere. There is a hole at the top and bottom of the void, which must not be plugged. Sometimes the presence of a plug indicates damage to the internal integrity of the tank. A tank found by enforcement staff with a plug will be placed out of service until the unit is repaired at a registered facility.

- 4 - TC 407/307 circular tank. These tanks are capable of operating at pressures higher than those set down for TC 406/306 tanks at 138 kpa (20 psi). They can be constructed to take all flammable liquids including the more volatile Packing Group I liquids, sour crude oil and some corrosives such as CORROSIVE LIQUIDS N.O.S (HYDROCHLORIC ACID). TC 412/312 circular tank. These tanks are capable of operating at pressures higher than those set down for TC 406/306 tanks. Some are steel with large outer stiffening rings and are often lined. The type of lining may prevent the construction of internal baffles in these units and hence they are usually long and narrow to minimize surging. Some tanks constructed to this standard are manufactured from fibreglass reinforced plastic. This type of tank is often used in dual service because it can handle both corrosive liquids and, with suitable grounding capabilities, flammable liquids such as crude oil.

- 5 - TC 331 is a high pressure tank designed for liquefied gases such as propane and anhydrous ammonia. They are designed for high pressures around 1723 kpa (250 psi) depending upon the liquefied gas. Additional features on these tanks may include off tank shutdown systems in the event of a failure during loading or offloading. TC 338 cryogenic gas insulated highway tanks. These are used for cold liquefied gases such as Nitrogen. A variation on this design is the TC 341, another cryogenic unit generally used for Oxygen. Both these types of tanks are designed in a similar manner to a Thermos bottle. They are engineered to keep the cold in and the heat out of the product by having a tank within a tank with a vacuum in-between to lessen heat transfer. They are not designed for high pressure service and operate at pressures of about 345 kpa (50psi) and above depending upon the product. These units often periodically vent gases to maintain the pressure in the tank, especially on hot days.

- 6 - TC 407/412/350 vacuum truck. These tanks are commonly designed with a characteristic large rear door, which opens for dumping. They are generally used for cleanup of chemical spills, oil spills and cleanout of storage tanks. They are also haul crude oil and water from the oil separation process at well heads. A unit dedicated to hauling crude oil may be designated as a TC 350 Crude and the certification plate on the tank would be marked accordingly. A full specification TC 350 tank must have a thermal and remote shutoff installed on all product outlet points, including mud gates, unless it is marked as a TC 350 Crude. As with TC 406/306 Crude tanks, only crude oil or water/oil mixtures from an oil well would be allowed in one of these units. TC 3AXM/3AAXM/3T tube trailers are specialized units that are designed to the CSA B340 Standard used for cylinders. They hold gases, which cannot be easily liquefied, such as natural gas, at very high pressure. These units are usually re-tested using acoustic methods under permits issued by Transport Canada. U.S. DOT units are allowed if they were constructed and in service in Canada prior to January 1, 1993.

- 7 - Identification Plates All tanks used in the service of transporting dangerous goods must have a plate attached to the shell or an integral part of the structure of the tank. The plate must be constructed of a metal that is not subject to corrosion and it must be located on the left side of the tank near the front or, prior to 1 July 1985, on the right side near the front. The plate must be legible. A tank built after 1 July 1995 must be built to the CSA B620 standard and must have a plate attached to it with at least the following information (5.1.6.1.6 in CSA B620): TC Specification e.g. TC 406 or TC 406 Crude; tank vehicle assembler (Tank veh. assembler); tank vehicle serial number; tank vehicle completion and certification date month and year (cert. date); tank manufacturer (Tank mfr.); tank maximum allowable pressure in kpa (MAWP); tank test pressure in kpa (Test P); vessel material specification number; weld material (Weld Matl.); minimum allowable thickness of shell in millimeters (Min. shell thick); minimum allowable thickness of heads in millimeters (Min. head thick); volumetric capacity in litres (Vol. Cap. Litres); date of tank manufacture month and year (Date of mfr.). Manufacturer *Note: Additional information may be required depending on the type of tank and when the tank was constructed. Please refer to the version of the CSA B620 Standard at the time of construction of the tank when determining what information is needed on the tank plate.

- 8 - Tank Testing and Marking All tanks must be tested on a periodic basis as shown in the following table (Table 7.1 in CSA B620): Type External Inspection Internal Inspection Lining Inspection Leakage Test Pressure, Hydro or Pneumatic 406/306 1 year 5 years 1 year 5 years 406/306 Crude 2.5 years 5 years 2.5 years 5 years 407/307 1 year 5 years 1 year 5 years 407 Vacuum with full 6 months 5 years 1 year 2 years opening heads 412/312 1 year 5 years 1 year 5 years 412 Vacuum with full 6 months 5 years 1 year 2 years opening heads 423 1 year 1 year 1 year 5 years 350 6 months 1 year 1 year 2 years 350 Crude 1 year 1 year 1 year 2 years 331 1 year 5 years 1 year (2 years for Chlorine) 5 years (2 years for Chlorine) 338 1 year 5 years 341 1 year 10 years (unless alternative testing 10 years is used) 11 1 year 10 years if it has a manhole 1 year 5 years 51 Portable 2.5 years 5 years 5 years 5 years 56/57 Portable 2.5 years 2.5 years 60 Portable 2 years 4-8-10-12 years 4-8-10-12 years 4-8-10-12 years then every year then every year then every year Types 1,2 and 3 Intermodal 2.5 years 2.5 years 5 years 5 years UN 31 Intermediate Bulk Container (Slip Tanks) 5 years 5 years Lined and unlined tanks in corrosive service must have an annual internal inspection. The lined tanks must also have the lining checked at the same time interval. Unlined tanks in corrosive service must have an annual internal inspection and a thickness test done every 2 years. All tanks with an upper coupler must have the tank checked for corrosion under the upper coupler every 5 years. For additional requirements, refer to Table 7.1, Table 7.2, Table 7.3 and related legend from CSA B620.

- 9 - Each tank must be marked on the side near the metal identification plate or head end with the following letters, as applicable, to show that the periodic tests have been carried out. A new tank requires the initial test information on the manufacturer s plate only: Letter V I P T L K UC WF C Visual (External) Inspection Internal Inspection Pressure Test Thickness Test Lining Inspection Leak Test Upper Coupler Area Inspection Test or Inspection Wet Fluorescent Magnetic Particle Inspection For TC 341 tanks only if a Cold Vacuum Retention test has been carried out instead of an internal (alternative testing). The date the tests were carried out must also appear on the tank, for example (one possible format): 02/09 V I K P 123 shows that visual, internal, leak and pressure tests were carried out in February 2009. The digits 123 represent the last three digits in the Transport Canada registration number of the test facility.