Specifications. Fluid Operating pressure Operating temperature Cover. Material. Model/Rated Flow Rate. Port size (Rc)

Similar documents
Hydraulic Filters. Element (µm) nominal filtration. Port size. Micromesh 74, 105, 149 1/2, 3/4, 1, 1 1/4, 1 1/2, 2, 2 1/2, 3, 3 1/2, 4

Specifications. Model/Rated Flow Rate. Accessory/Option. Differential pressure indicator

Suction Filter with Case. Specifications. Fluid Operating pressure Operating temperature Cover/Case. Model/Rated Flow Rate. Model

The filters for hydraulic fluids are used to protect each component in a hydraulic circuit. Port size. Micromesh 74, 105, 149

FHM Series. Magnetic Separator. RoHS FH HOW

Coolant Valve. VNC Series. Cylinder actuation by pilot air

Standard Specifications. Fluid Standard specifications. VH600 Ambient and fluid temperature Operating angle Lubrication. Optional Specifications

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

Micro Mist Separator. Model. Note) 1 8, , , , , 1. Model/Free Standing Type. Model AMD (2B)JIS 10K FF flange

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

HIGH PRESSURE FILTERS

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

Specifications VH600. Ambient temperature and operating fluid temperature. Operating angle Lubrication. Semi-standard

Coolant Valve. Air Operated/External Pilot Solenoid

Air Suction Filter / In-line Type With One-touch Fittings. Model ZFC ZFC ZFC ZFC ZFC ZFC ZFC ZFC051-03

Reducing Valve/Reducing Valve with Check Valve

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

Duplex Pressure Filters

Inline Filter DMG DMG 080 DMG 045 DMG FILTER SPECIFICATIONS. Temperature range -10 C to +100 C Material of filter housing

Ready for outdoor use too!

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

5 Port Solenoid Valve

HYDRAULICS VINCKE HYDRAULIC PUMPS

Bag Filter. Latch mechanism. has been provided additionally. (Mechanism for protecting the cover from being removed)

Series IW. Filter Regulator

Exclusively for air pressure system and air-hydro circuit control

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

Impulse Lubricator. Standard Specifications

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

F1000/F3000/F4000/F8000 Series

Low Maintenance Filter

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Low Maintenance Filter

FLOW CONTROL VALVES F CONTROL VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.] Maximum flow rate L/min. Page

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

MEDIUM PRESSURE FILTERS

Series RFLD Duplex In-Line Filter

Series RFL In-Line Filter

HIGH PRESSURE FILTERS

Manifold Specifications

PRESSURE REDUCING AND RELIEVING VALVES

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

UNLOADING RELIEF VALVES

D e s c r i p t i o n

Series VP3145/3165/3185

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Vacuum / Release Unit

Compressed Air Cleaning Filter Series

Pressure Filter DF...K P, DF...M P, Flange Mounted

ALB900 Series. Standard Specifications. Model. Port (Bypass lubrication adapter)

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

3 Port Solenoid Valve Direct Operated Poppet Type

L1000/L3000/L4000/L8000-W Series

PROPORTIONAL VALVES SERVO VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.]

Hydraulic Fluids. Note: For use with hydraulic fluids other than those listed above, please consult your Yuken representatives in advance.

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Air Suction Filter. Series ZF. Prevent from occurring vacuum equipment trouble due to dust from vacuum pad ZFA ZFB ZFC

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Inline filter with filter element according to DIN 24550

PRESSURE REDUCING AND RELIEVING VALVES

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication

Standard Specifications. Model. Port (Bypass lubrication adapter)

How to Order 02 1/4. Thread type Nil Rc N NPT * * Semi-standard

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure

Low Torque Rotary Joint

Change-Over Pressure Filter DFDK

A Series Variable Displacement Piston Pumps

4 Port Solenoid Valve

HIGH PRESSURE FILTERS DF/DFF 1500 Series Inline Filters 6090 psi up to 250 gpm

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Standard Specifications. Model. Port (Bypass lubrication adapter)

Air Filter. Best Pneumatics 4. Equipment. Air Line

VINCKE HYDRAULIC PUMPS

Pressure Control Valves

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Check Valve Series AK How to Order

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42)

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

Low Torque Rotary Joint

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

4 Port Solenoid Valve

Flow rates to 500 l/min

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

Return Line Filter RF

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

Discharge rate* 2 L/min MPa (DE10-1) 37.8 MPa (DE10-7)

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. 3 (Closed center) 3/4, 1 3 (Exhaust center)

Transcription:

Return Filter Series FH Selection of elements for different applications Depending on the application, the user can choose among several standard element types, paper elements (, and µm) and micromesh elements (7 and µm). Easy maintenance The element slides into place and is sealed with an O-ring, making it easy to install and remove. Large drain exhaust outlet The large M6 drain exhaust outlet assures rapid drainage. logging sensor The filter can be fitted with a differential pressure indicator (two-stage indicator, reset type) or differential pressure (visual combined, non-reset type). Specifications Fluid Operating pressure Operating temperature over Hydraulic fluid Max. MPa Max. 8 ast iron Main material ase O-ring Seal Aluminum-cast NBR or FKM Note) Stainless steel & NBR or Stainless steel & FKM Note) Material Paper Micromesh Nominal filtration,, µm 7, µm (, mesh) Differential pressure resistance Differential pressure indicator operating pressure Relief valve open pressure.6 MPa. MPa. MPa Note) The material of the O-rings differs depending on the hydraulic fluid used. Petroleum, Water-glycol, Emulsion: NBR; : FKM /Rated Flow Rate FH-6 FH-8 FH- FH- FH-6 FH- FH- Port size (Rc) / / / / Rated flow rate (l/min) Paper Micromesh 8 6 6 6 6 7 Accessory/Option Description Part no. Note Differential pressure indicator B-H Petroleum, Water-glycol, Emulsion B-H-V Differential pressure (N.. and N.O. common) Blanking cap (for differential pressure indication part) B-H B-H-V AG-H AG-H-W AG-H-V Petroleum, Water-glycol, Emulsion Petroleum Water-glycol, Emulsion

Series FH Port size (Rc) 6 8 6 Hydraulic filter Operating pressure B Max. MPa onstruction/onnection downward removal, threaded / / / / FH 6 P Differential pressure indication None Differential pressure indicator Differential pressure Note) Note) N.. and N.O. common How to Order Relief valve With relief valve None Hydraulic fluid P M 7 Nil None X Non-standard filtration Note) The non-standard filtration is for micromesh elements only. Refer to page for details. Nominal filtration µm µm µm 7 µm µm Note) The paper elements for water-glycol or emulsion is µm only. Paper Micromesh Petroleum Water-glycol, Emulsion Made to Order Replacement Part No. (including O-ring for element) FH-6 FH-8 FH- FH- FH-6 FH- FH- µm EP-N EP-N EP-N EP-N EP-N EP6-N EP6-N Paper µm EP-N EP-N EP-N EP-N EP-N EP6-N EP6-N µm EP-N EP-N EP-N EP-N EP-N EP6-N EP6-N 7 µm ( mesh) EM8-7N EM8-7N EM9-7N EM9-7N EM-7N EM-7N EM-7N Micromesh Note ) The symbol at the end of the element part no. indicates the hydraulic fluid type. N: Petroleum, V:, W: Water-glycol, Emulsion ( µm only for paper) Note ) Refer to page for non-standard filtration. Note ) Above elements require one element per filter. µm ( mesh) EM8-N EM8-N EM9-N EM9-N EM-N EM-N EM-N size ø6 x 9 ø7 x 7 ø88 x 8 ø9 x 8 onstruction/seal List Blanking cap Relief valve q O-ring w O-ring e Seal washer Drain plug DRAIN Differential pressure indicator over OUT ase Differential pressure Differential pressure Replacement Seal List (One each of the seal and O-ring types listed below are required per filter.) No. Descrip- tion Hydraulic fluid type 6 8 Petroleum, FH- Emulsion, 6 Water-glycol AN6-7 NBR/Hs = 7 6 8 -D-G9 Phosphoric FH- ester 6 O-ring for cover case JIS B -A-G9 JIS B -A-G JIS B -A-P JIS B -A-P JIS B -A-P JIS B -A-P8 JIS B -D-P JIS B JIS B -D-G AN6-7 FPM/Hs = 7 O-ring for element JIS B -D-P JIS B -D-P JIS B -D-P8 Seal washer Standard Standard Part no. SM-6 SM-6-V

Return Filter Series FH Flow haracteristics FH-6 to : Nominal filtration µm Pressure drop (MPa)..... 6 6 8. Flow rate (l/min) onditions Fluid: Turbine oil lass VG6 Measured pressure: MPa Viscosity: mm /s Filter material: Paper Nominal filtration: µm FH-6 to : Nominal filtration 7 µm Pressure drop (MPa)..... 6 8 6 Differential Pressure Indication Two indication methods are available: differential pressure indicator and differential pressure. These can be mounted on all filter models. Differential pressure indicator Operating pressure. MPa Once a value is displayed, it will continue to be displayed until reset, even if the pump is stopped. (-stage display reset type) Perform element replacement when the red ring floats up and covers the entire view port. Reset button View port Differential pressure Operating pressure. MPa When a value has been displayed, it will be automatically reset when the pump is stopped. (Non-reset type) This is a visual dual-purpose -stage display. Perform element replacement when the switch has actuated (when the red ring floats up and covers the entire view point). N.. and N.O. common OM. N.O. N.. View port G/ Handling Precautions q Mounting onfirm and OUT before mounting. Then connect so that the drain is oriented downward. For maintenance, make sure to provide sufficient space above the filter for removing the element. w Operation Operation of the differential pressure indicator in cold weather, such as during winter, mostly occurs due to high viscosity, so check whether it is from clogging or not after normal operation starts. Once the differential pressure indicator is actuated, the indication continues to be displayed until the indicator is reset (by depressing the reset button), even if the pump stops operating. Reset after replacing the element and restarting operation, or after normal operation starts in cold weather such as during winter. When using a differential pressure indication switch and if a filter clogged signal is incorporated into the sequence circuit of the machine, make sure to design the system so the filter clogged signal does not operate until normal operation starts. e replacement When the pressure difference reaches. MPa during filter operation (actuating the differential pressure indicator), stop operation, drain the oil from the case, and replace the paper element or wash the micromesh element. If the micromesh element has reached the end of its service life, replace it. When replacing the element, check the O- rings and replace them if they are damaged. When washing the micromesh element, do not wipe it using a stiff brush or rag.. Flow rate (l/min) onditions Fluid: Turbine oil lass VG6 Measured pressure: MPa Viscosity: mm /s Filter material: Micromesh Nominal filtration: 7 µm Microswitch Rating Non-inductive load (A) Inductive load (A) Rated Resistance load Light load Inductive load Motor load voltage (V) Normally Normally Normally Normally Normally Normally Normally Normally closed open closed open closed open closed open A A D8 D D D D....7.........8.. Precautions. The figures in the above table indicate stationary current.. An inductive load has a power factor (A) of.7 or more, and a time constant (D) of 7 msec or less.. A light load has an inrush current times greater.. Lead wires are connected using a screw tightening terminal.. The electrical entry is equipped with a conduit (G/) and grommet. 6. Please wire freely to the microswitch indication symbol (OM.), (N..) and (N.O.). 7. If a holding mechanism is necessary for the nonreset type, provide it using electric circuits.

Series FH Dimensions Differential pressure øf Differential pressure indicator 6 A Blanking cap x Rc (d) () (6) OUT- OUT- E ( removal dimension) øb OUT- D Differential pressure indicator Differential pressure DRAIN FH-6 FH-8 FH- FH- FH-6 FH- FH- d A B / 9 / / 8 / 7 D E 6 9 8 99 7 87 F 7 (mm) Weight (kg).. 6.8 7.

Series FH Made to Order (Non-Standard Filtration) Please contact SM for detailed specifications, lead times and prices. How to Order Filter symbol (Refer to How to Order for each series) Note) Made-to-order specifications (non-standard filtration rating) are available only for micromesh elements (element symbol: M). X Made to Order (Non-standard filtration) Hydraulic Filter Non-Standard Filtration Replacement Part No. Replacement element part no. Description Port size Micromesh element Micromesh element (With relief valve) size / EMH-* * ø6 x l9 /, EMH-* * ø8 x l Vertical suction filter FHIA (Refer to P..) /, / EMH-* * EMH-* * ø x l6 ø x l8 /, EMH-* * ø x l /, EMH-* * ø8 x l6 /, / EM-* * EM-* * ø6 x l9, / EM-* * EM6-* * ø8 x l Suction filter with case FH99 (Refer to P. 7.) / / EM-* * EM-* * EM6-* * EM7-* * EM8-* * EM9-* * ø x l77 ø x l77 ø x l EM7-* * EM-* * ø x l /, EM8-* * EM-* * ø x l9 Suction guard FHG (Refer to P..) /, /, /, /, /, EM-* * EM-* * EM-* * ø69 x l88 ø89 x l ø9 x l88 Line filter FH FH FH FH6 (Refer to P..) /8, / /, /, / /, EM-* * EM9-* * EM-* * EM9-* * EM-* * ø. x l9 ø7. x l7 ø7. x l9 ø87.6 x l8 ø8.7 x l8 Vertical return filter FHBA (Refer to P. 9.) / / / EM6H-* * EM7H-* * EM8H-* * ø6 x l8 ø76 x l9 ø76 x l9 /, EM8-* * ø6 x l9 Return filter FH (Refer to P..) /, / EM9-* * EM-* * ø7. x l7 ø87.6 x l7 /, EM-* * ø8.7 x l7 Oil filter FH (Refer to P. 6.) /, /8, / EM-* * ø x l9 Note) In the table above indicates nominal filtration and indicates hydraulic fluid type. Nominal Filtration Symbol ( ) 7 9 7 µm 7 9 7 Hydraulic Fluid Symbol ( ) N W V Type Petroleum Water-glycol, Emulsion